Domingo Muñoz I, Van Hoey O, Parisi A, Bassler N, Grzanka L, De Saint-Hubert M, Vaniqui A, Olko P, Sądel M, Stolarczyk L, Vestergaard A, Jäkel O, Gardenali Yukihara E, Brage Christensen J. Assessment of fluence- and dose-averaged linear energy transfer with passive luminescence detectors in clinical proton beams. Phys Med Biol 2024; 69:135004. [PMID: 38774985 DOI: 10.1088/1361-6560/ad4e8e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 05/21/2024] [Indexed: 06/22/2024]
Abstract
Objective.This work investigates the use of passive luminescence detectors to determine different types of averaged linear energy transfer (LET-) for the energies relevant to proton therapy. The experimental results are compared to reference values obtained from Monte Carlo simulations.Approach.Optically stimulated luminescence detectors (OSLDs), fluorescent nuclear track detectors (FNTDs), and two different groups of thermoluminescence detectors (TLDs) were irradiated at four different radiation qualities. For each irradiation, the fluence- (LET-f) and dose-averaged LET (LET-d) were determined. For both quantities, two sub-types of averages were calculated, either considering the contributions from primary and secondary protons or from all protons and heavier, charged particles. Both simulated and experimental data were used in combination with a phenomenological model to estimate the relative biological effectiveness (RBE).Main results.All types ofLET-could be assessed with the luminescence detectors. The experimental determination ofLET-fis in agreement with reference data obtained from simulations across all measurement techniques and types of averaging. On the other hand,LET-dcan present challenges as a radiation quality metric to describe the detector response in mixed particle fields. However, excluding secondaries heavier than protons from theLET-dcalculation, as their contribution to the luminescence is suppressed by ionization quenching, leads to equal accuracy betweenLET-fandLET-d. Assessment of RBE through the experimentally determinedLET-dvalues agrees with independently acquired reference values, indicating that the investigated detectors can determineLET-with sufficient accuracy for proton therapy.Significance.OSLDs, TLDs, and FNTDs can be used to determineLET-and RBE in proton therapy. With the capability to determine dose through ionization quenching corrections derived fromLET-, OSLDs and TLDs can simultaneously ascertain dose,LET-, and RBE. This makes passive detectors appealing for measurements in phantoms to facilitate validation of clinical treatment plans or experiments related to proton therapy.
Collapse
Affiliation(s)
- Iván Domingo Muñoz
- Department of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| | | | - Alessio Parisi
- Department of Radiation Oncology, Mayo Clinic, Jacksonville, Florida, United States of America
| | - Niels Bassler
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| | - Leszek Grzanka
- Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN), Kraków, Poland
| | | | - Ana Vaniqui
- Belgian Nuclear Research Center (SCK CEN), Mol, Belgium
| | - Paweł Olko
- Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN), Kraków, Poland
| | - Michał Sądel
- Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN), Kraków, Poland
| | - Liliana Stolarczyk
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| | - Anne Vestergaard
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| | - Oliver Jäkel
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- Department of Radiation Oncology, Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, Heidelberg, Germany
| | | | - Jeppe Brage Christensen
- Department of Radiation Safety and Security, Paul Scherrer Institute (PSI), Villigen PSI, Switzerland
| |
Collapse
|
2
|
Evaluation and modelling of the lithium fluoride based thermoluminescent detector response at the CERN-EU high-energy reference field (CERF). RADIAT MEAS 2023. [DOI: 10.1016/j.radmeas.2023.106923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/26/2023]
|
3
|
Evaluation of different types of lithium fluoride thermoluminescent detectors for ring dosimetry in nuclear medicine. RADIAT MEAS 2022. [DOI: 10.1016/j.radmeas.2022.106866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
4
|
Van Hoey O, Parisi A. Development and validation of a model for assessing neutron fluence with lithium fluoride thermoluminescent detectors. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109688] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
5
|
Sadeghi E, Zahedifar M, Rezaii P. Neutron-gamma mixed field dosimetry using a 6LiF:Mg,Cu,P thermoluminescent dosimeter. NUCLEAR TECHNOLOGY AND RADIATION PROTECTION 2021. [DOI: 10.2298/ntrp2104346s] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
Satisfactory discrimination between the neutron and gamma components in a
mixed neutron-gamma field is one of the most important objectives of
neutron dosimetry. One of the common techniques for estimating gamma and
neutron dose components in mixed neutron-gamma fields is the two peak
method. This method has been applied using dosimeters such as LiF:Mg,Ti, but
in the present work, a 6LiF:Mg,Cu,P dosimeter has been used, whose
thermoluminescence sensitivity is much higher than the LiF:Mg,Ti dosimeter,
and therefore, if appropriate results are achieved, it can drastically
reduce the dose estimation threshold. Applicability of 6LiF:Mg,Cu,P for
estimation of the gamma dose using the two peak method in a mixed thermal
neutron-gamma radiation field was studied. The ratio of the area underneath
the high temperature thermoluminescence glow peak to dosimetry peak of this
phosphor in an Am-Be neutron field is 0.127, while this ratio in a pure
gamma ray field of 137Cs is 0.039. The calibration curves were obtained by
separately irradiating 6LiF:Mg,Cu,P chips with known gamma and neutron
doses. Results show that 6LiF:Mg,Cu,P can be used to estimate the
contributions of neutron and gamma doses in a mixed neutron-gamma field by
using the two peak method.
Collapse
Affiliation(s)
- Ehsan Sadeghi
- Physics Department, University of Kashan, Kashan, Iran + Institute of Nanoscience and Nanotechnology, University of Kashan, Kashan, Iran
| | - Mostafa Zahedifar
- Physics Department, University of Kashan, Kashan, Iran + Institute of Nanoscience and Nanotechnology, University of Kashan, Kashan, Iran
| | | |
Collapse
|
6
|
Olko P, Bilski P. MICRODOSIMETRIC UNDERSTANDING OF DOSE RESPONSE AND RELATIVE EFFICIENCY OF THERMOLUMINESCENCE DETECTORS. RADIATION PROTECTION DOSIMETRY 2020; 192:165-177. [PMID: 33418564 PMCID: PMC7840113 DOI: 10.1093/rpd/ncaa211] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 10/20/2020] [Accepted: 11/23/2020] [Indexed: 06/12/2023]
Abstract
LiF:Mg,Ti detectors show relative efficiency η for heavy charged particles significantly lower than one. It was for a long time not recognised that η varies also for electron energies and, as a consequence for photons. For LiF:Mg,Cu,P detectors measured photon energy response was named 'anomalous' because it differed significantly from the ratio of photon absorption coefficients. The decrease of η was explained as a microdosimetric effect due to local saturation of trapping centres around the electron track. For TLD-100 it was noticed by Horowitz that the measured photon energy response disagrees with the ratio of absorption coefficient by about 10%. It was demonstrated that a fraction of the TL signal in LiF:Mg,Ti is generated in the supralinear dose-response range, due to the high local doses generated by photon-induced tracks. Prediction of TL efficiency is particularly important in space dosimetry and in dosimetry of therapeutic beams like protons or carbon ions.
Collapse
Affiliation(s)
- Paweł Olko
- Institute of Nuclear Physics Polish Academy of Sciences, Radzikowskiego 152, PL-31-342 Kraków, Poland
| | - Paweł Bilski
- Institute of Nuclear Physics Polish Academy of Sciences, Radzikowskiego 152, PL-31-342 Kraków, Poland
| |
Collapse
|
7
|
The relative efficiency of 7LiF:Mg,Ti (MTS-7) and 7LiF:Mg,Cu,P (MCP-7) thermoluminescent detectors for muons, pions and kaons over a broad energy range (2 keV–1 GeV): theoretical calculations using the Microdosimetric d(z) Model. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2020.109096] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
8
|
Parisi A. FURTHER CLARIFICATIONS ON THE MICRODOSIMETRIC D(Z) MODEL IN RESPONSE TO 'THE RECENT SUCCESS OF MICRODOSIMETRY' BY Y.S. HOROWITZ. RADIATION PROTECTION DOSIMETRY 2020; 189:534-538. [PMID: 32347932 DOI: 10.1093/rpd/ncaa055] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 02/18/2020] [Accepted: 04/05/2020] [Indexed: 06/11/2023]
Abstract
After a short review of the achievements of the Microdosimetric d(z) Model in describing and predicting the response of luminescent detectors for different exposure conditions, recent comments and suggestions are systematically addressed also in light of more recent findings.
Collapse
|
9
|
A new method to predict the response of thermoluminescent detectors exposed at different positions within a clinical proton beam. RADIAT MEAS 2020. [DOI: 10.1016/j.radmeas.2020.106281] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
10
|
Mitigation of the proton-induced low temperature anomaly of LiF:Mg,Cu,P detectors using a post-irradiation pre-readout thermal protocol. RADIAT MEAS 2020. [DOI: 10.1016/j.radmeas.2019.106233] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
11
|
Parisi A, Olko P, Swakoń J, Horwacik T, Jabłoński H, Malinowski L, Nowak T, Struelens L, Vanhavere F. Modeling the radiation-induced cell death in a therapeutic proton beam using thermoluminescent detectors and radiation transport simulations. ACTA ACUST UNITED AC 2020; 65:015008. [DOI: 10.1088/1361-6560/ab491f] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
12
|
Villanueva A, Goddard B. LOSS OF TLD SIGNAL DUE TO HIGH TEMPERATURE ENVIRONMENTAL CONDITIONS. RADIATION PROTECTION DOSIMETRY 2019; 187:17-20. [PMID: 31204777 DOI: 10.1093/rpd/ncz130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2018] [Revised: 04/10/2019] [Accepted: 04/17/2019] [Indexed: 06/09/2023]
Abstract
While it is known that temperatures above 100°C have an effect on the reported dose of a TLD, it is less widely known what the susceptibility is to temperatures below 100°C, temperatures humans could reasonably expect to be exposed to. With the expanding nuclear industry in climates with more extreme temperatures, (e.g. United Arab Emirates and Saudi Arabia) the effect on a TLD if left on a dashboard of a car need to be evaluated. This research experimentally determined the extent of this thermal susceptibility by testing a range of high temperatures, 40°C - 90°C. The experimental results found that there is a statistically significant reduction in TLD-100H (natLiF:Mg,Cu,P) light output for TLDs there were exposed to temperatures as low as 40°C for 8 hour durations and 50°C for 2 hour durations. There is statistical difference in TLD-100H light output for elevated temperature durations of 8 hours compared to 24 hours.
Collapse
Affiliation(s)
- Andrew Villanueva
- Virginia Commonwealth University, West Main Street, P.O. Box, Richmond, VA
| | - Braden Goddard
- Virginia Commonwealth University, West Main Street, P.O. Box, Richmond, VA
| |
Collapse
|
13
|
Parisi A, Dabin J, Schoonjans W, Van Hoey O, Mégret P, Vanhavere F. Photon energy response of LiF:Mg,Ti (MTS) and LiF:Mg,Cu,P (MCP) thermoluminescent detectors: Experimental measurements and microdosimetric modeling. Radiat Phys Chem Oxf Engl 1993 2019. [DOI: 10.1016/j.radphyschem.2019.05.021] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
14
|
Tsai HY, Sung CH, Chen HH, Lin MW, Huang HC, Chang SL. Clinical application of ionization density dependence of the glow curve for measuring linear energy transfer in therapeutic proton beams. RADIAT MEAS 2019. [DOI: 10.1016/j.radmeas.2019.106146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
15
|
Parisi A, Chiriotti S, De Saint-Hubert M, Van Hoey O, Vandevoorde C, Beukes P, de Kock EA, Symons J, Camero JN, Slabbert J, Mégret P, Debrot E, Bolst D, Rosenfeld A, Vanhavere F. A novel methodology to assess linear energy transfer and relative biological effectiveness in proton therapy using pairs of differently doped thermoluminescent detectors. Phys Med Biol 2019; 64:085005. [PMID: 30650402 DOI: 10.1088/1361-6560/aaff20] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
A new methodology for assessing linear energy transfer (LET) and relative biological effectiveness (RBE) in proton therapy beams using thermoluminescent detectors is presented. The method is based on the different LET response of two different lithium fluoride thermoluminescent detectors (LiF:Mg,Ti and LiF:Mg,Cu,P) for measuring charged particles. The relative efficiency of the two detector types was predicted using the recently developed Microdosimetric d(z) Model in combination with the Monte Carlo code PHITS. Afterwards, the calculated ratio of the expected response of the two detector types was correlated with the fluence- and dose- mean values of the unrestricted proton LET. Using the obtained proton dose mean LET as input, the RBE was assessed using a phenomenological biophysical model of cell survival. The aforementioned methodology was benchmarked by exposing the detectors at different depths within the spread out Bragg peak (SOBP) of a clinical proton beam at iThemba LABS. The assessed LET values were found to be in good agreement with the results of radiation transport computer simulations performed using the Monte Carlo code GEANT4. Furthermore, the estimated RBE values were compared with the RBE values experimentally determined by performing colony survival measurements with Chinese Hamster Ovary (CHO) cells during the same experimental run. A very good agreement was found between the results of the proposed methodology and the results of the in vitro study.
Collapse
Affiliation(s)
- Alessio Parisi
- Belgian Nuclear Research Centre SCK·CEN, Mol, Belgium. University of Mons, Faculty of Engineering, Mons, Belgium. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Parisi A, Van Hoey O, Mégret P, Vanhavere F. Microdosimetric specific energy probability distribution in nanometric targets and its correlation with the efficiency of thermoluminescent detectors exposed to charged particles. RADIAT MEAS 2019. [DOI: 10.1016/j.radmeas.2018.12.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
17
|
Low temperature thermoluminescence anomaly of LiF:Mg,Cu,P radiation detectors exposed to 1H and 4He ions. RADIAT MEAS 2018. [DOI: 10.1016/j.radmeas.2018.10.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|