• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4632662)   Today's Articles (2441)   Subscriber (49920)
For: Kallis K, Abu-Hossin N, Kreppner S, Lotter M, Strnad V, Fietkau R, Bert C. Estimation of inter-fractional variations in interstitial multi-catheter breast brachytherapy using a hybrid treatment delivery system. Radiother Oncol 2019;141:312-320. [PMID: 31495517 DOI: 10.1016/j.radonc.2019.08.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Revised: 08/13/2019] [Accepted: 08/14/2019] [Indexed: 11/30/2022]
Number Cited by Other Article(s)
1
Androulakis I, Schiphof-Godart J, van Heerden LE, Luthart L, Rijnsdorp R, Hoogeman MS, Westerveld H, Christianen MEMC, Mens JWM, van Paassen R, Negenman EM, Nout RA, Karine K Kolkman-Deurloo I. Assessment of integrated electromagnetic tracking for dwell position monitoring in a clinical HDR brachytherapy setting for prostate cancer. Radiother Oncol 2024;200:110501. [PMID: 39191302 DOI: 10.1016/j.radonc.2024.110501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 08/08/2024] [Accepted: 08/19/2024] [Indexed: 08/29/2024]
2
Dürrbeck C, Gomez-Sarmiento IN, Androulakis I, Sauer BC, Kolkman-Deurloo IK, Bert C, Beaulieu L. A comprehensive quality assurance protocol for electromagnetic tracking in brachytherapy. Med Phys 2024;51:3184-3194. [PMID: 38456608 DOI: 10.1002/mp.17017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 01/31/2024] [Accepted: 02/24/2024] [Indexed: 03/09/2024]  Open
3
Gomez-Sarmiento IN, Tho D, Dürrbeck C, de Jager W, Laurendeau D, Beaulieu L. Accuracy of an electromagnetic tracking enabled afterloader based on the automated registration with CT phantom images. Med Phys 2024;51:799-808. [PMID: 38127342 DOI: 10.1002/mp.16903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 12/05/2023] [Accepted: 12/08/2023] [Indexed: 12/23/2023]  Open
4
Dürrbeck C, Schuster S, Sauer BC, Abu-Hossin N, Strnad V, Fietkau R, Bert C. Localization of reference points in electromagnetic tracking data and their application for treatment error detection in interstitial breast brachytherapy. Med Phys 2023;50:5772-5783. [PMID: 37458615 DOI: 10.1002/mp.16629] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 06/27/2023] [Accepted: 06/29/2023] [Indexed: 09/11/2023]  Open
5
Dürrbeck C, Schulz M, Pflaum L, Kallis K, Geimer T, Abu-Hossin N, Strnad V, Maier A, Fietkau R, Bert C. Estimating follow-up CTs from geometric deformations of catheter implants in interstitial breast brachytherapy: A feasibility study using electromagnetic tracking. Med Phys 2023;50:5793-5805. [PMID: 37540071 DOI: 10.1002/mp.16659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 06/20/2023] [Accepted: 07/21/2023] [Indexed: 08/05/2023]  Open
6
Automating implant reconstruction in interstitial brachytherapy of the breast: A hybrid approach combining electromagnetic tracking and image segmentation. Radiother Oncol 2022;176:172-178. [PMID: 36181920 DOI: 10.1016/j.radonc.2022.09.019] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2022] [Revised: 08/24/2022] [Accepted: 09/23/2022] [Indexed: 12/14/2022]
7
Dürrbeck C, Gulde S, Abu-Hossin N, Fietkau R, Strnad V, Bert C. Influence and compensation of patient motion in electromagnetic tracking based quality assurance in interstitial brachytherapy of the breast. Med Phys 2022;49:2652-2662. [PMID: 35143053 DOI: 10.1002/mp.15517] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 12/21/2021] [Accepted: 01/21/2022] [Indexed: 11/08/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA