1
|
Kadhim M, Haraldsson A, Kügele M, Enocson H, Bäck S, Ceberg S. Surface guided ring gantry radiotherapy in deep inspiration breath hold for breast cancer patients. J Appl Clin Med Phys 2024:e14463. [PMID: 39138877 DOI: 10.1002/acm2.14463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 04/22/2024] [Accepted: 06/24/2024] [Indexed: 08/15/2024] Open
Abstract
PURPOSE This study investigated the use of surface guided radiotherapy (SGRT) in combination with a tomotherapy treatment mode using discrete delivery angles for deep inspiration breath hold (DIBH) treatments of breast cancer (bc). We aimed to assess the feasibility and dosimetric advantages of this approach. MATERIALS AND METHODS We evaluated camera occlusion in the Radixact treatment system bore and the stability of DIBH signals during couch movement. The SGRT system's ability to maintain signal and surface image accuracy was analyzed at different depths within the bore. Dosimetric parameters were compared and measured for 20 left-sided bc patients receiving TomoDirect (TD) tangential radiotherapy in both DIBH and free breathing (FB). RESULTS The SGRT system maintained surface coverage and precise DIBH-signal at depths up to 40 cm beyond the treatment center. Camera occlusion occurred in the clavicular and neck regions due to the patient's morphology and gantry geometry. Nonetheless, the system accurately detected respiratory motion for all measurements. The DIBH plans significantly (p < 0.001) reduced mean heart and left anterior descending artery (LAD) radiation doses by up to 40%, with a 50% reduction in near-maximum heart and LAD doses, respectively. No significant dosimetric differences between DIBH and FB were observed in other investigated parameters and volumes. CONCLUSIONS Camera occlusion and couch movement minimally impacted the real-time surface image accuracy needed for DIBH treatments of bc. DIBH reduced heart and LAD radiation doses significantly compared to FB, indicating the feasibility and dosimetric benefits of combining these modalities.
Collapse
Affiliation(s)
- Mustafa Kadhim
- Department of Medical Radiation Physics, Lund University, Lund, Sweden
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - André Haraldsson
- Department of Medical Radiation Physics, Lund University, Lund, Sweden
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - Malin Kügele
- Department of Medical Radiation Physics, Lund University, Lund, Sweden
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - Hedda Enocson
- Department of Medical Radiation Physics, Lund University, Lund, Sweden
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - Sven Bäck
- Department of Medical Radiation Physics, Lund University, Lund, Sweden
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - Sofie Ceberg
- Department of Medical Radiation Physics, Lund University, Lund, Sweden
| |
Collapse
|
2
|
Lai J, Luo Z, Jiang L, Hu H, Gao C, Zhang C, Chen L, Wu J, Wu Z. Skin marker combined with surface-guided auto-positioning for breast DIBH radiotherapy daily initial patient setup: An optimal schedule for both accuracy and efficiency. J Appl Clin Med Phys 2024; 25:e14319. [PMID: 38522035 PMCID: PMC11244673 DOI: 10.1002/acm2.14319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2023] [Revised: 01/31/2024] [Accepted: 02/12/2024] [Indexed: 03/25/2024] Open
Abstract
BACKGROUND AND PURPOSE By employing three surface-guided radiotherapy (SGRT)-assisted positioning methods, we conducted a prospective study of patients undergoing SGRT-based deep inspiration breath-hold (DIBH) radiotherapy using a Sentine/Catalys system. The aim of this study was to optimize the initial positioning workflow of SGRT-DIBH radiotherapy for breast cancer. MATERIALS AND METHODS A total of 124 patients were divided into three groups to conduct a prospective comparative study of the setup accuracy and efficiency for the daily initial setup of SGRT-DIBH breast radiotherapy. Group A was subjected to skin marker plus SGRT verification, Group B underwent SGRT optical feedback plus auto-positioning, and Group C was subjected to skin marker plus SGRT auto-positioning. We evaluated setup accuracy and efficiency using cone-beam computed tomography (CBCT) verification data and the total setup time. RESULTS In groups A, B, and C, the mean and standard deviation of the translational setup-error vectors were small, with the highest values of the three directions observed in group A (2.4 ± 1.6, 2.9 ± 1.8, and 2.8 ± 2.1 mm). The rotational vectors in group B (1.8 ± 0.7°, 2.1 ± 0.8°, and 1.8 ± 0.7°) were significantly larger than those in groups A and C, and the Group C setup required the shortest amount of time, at 1.5 ± 0.3 min, while that of Group B took the longest time, at 2.6 ± 0.9 min. CONCLUSION SGRT one-key calibration was found to be more suitable when followed by skin marker/tattoo and in-room laser positioning, establishing it as an optimal daily initial set-up protocol for breast DIBH radiotherapy. This modality also proved to be suitable for free-breathing breast cancer radiotherapy, and its widespread clinical use is recommended.
Collapse
Affiliation(s)
- Jianjun Lai
- Instiute of Intelligent Control and RoboticsHangzhou Dianzi UniversityHangzhouChina
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| | - Zhizeng Luo
- Instiute of Intelligent Control and RoboticsHangzhou Dianzi UniversityHangzhouChina
| | - Lu Jiang
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| | - Haili Hu
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| | - Chang Gao
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| | - Chuanfeng Zhang
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| | - Liting Chen
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| | - Jing Wu
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| | - Zhibing Wu
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| |
Collapse
|
3
|
Li J, Yang L, Yao X, Xu L, Zhao L, Bai F. A retrospective study on improving the accuracy of radiotherapy for patients with breast cancer with lymph node metastasis using Styrofoam. Radiol Oncol 2024; 58:124-132. [PMID: 38183274 PMCID: PMC10878773 DOI: 10.2478/raon-2024-0001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 08/15/2023] [Indexed: 01/08/2024] Open
Abstract
BACKGROUND To retrospectively analyze the accuracy of radiotherapy using cone beam computed tomography (CBCT), Styrofoam fixation, and breast bracket fixation in the chest wall target area and supraclavicular lymphatic drainage area (supraclavicular target area) of patients with breast cancer.and compare the setting efficiency and comfort satisfaction. PATIENTS AND METHODS A total of 65 patients with postoperative lymphatic metastasis of breast cancer, including 36 cases of Styrofoam fixation and 29 cases of breast bracket fixation, were recruited from March 2021 to August 2022 and retrospectively analyzed. All the patients underwent CBCT scans weekly, and the setup errors of the chest wall and supraclavicular target volume were compared and recorded. The planning target volume (PTV) margins of the two groups were calculated using the correlation MPTV = 2.5Σ + 0.7σ. The setup time and comfort satisfaction scores of the two groups were recorded and analyzed. The correlations among errors in each direction were analyzed using the Pearson correlation analysis. RESULTS There was a significant difference in the left-right direction (X) axis of the chest wall target area between the Styrofoam and breast bracket groups (1.59 ± 1.47 mm vs. 2.05 ± 1.64 mm, P = 0.012). There were statistical differences in the ventrodorsal direction (Z) and bed angle of the supraclavicular target area, the data were (1.36 ± 1.27 mm vs. 1.75 ± 1.55 mm, P = 0.046; 0.47 ± 0.47° vs. 0.66 ± 0.59°, P = 0.006, respectively). In the X, Y, and Z directions, the respective PTV margins of the two groups in the chest wall target area were 5.01 mm, 5.99 mm, and 5.47 mm in the Styrofoam group, while those in the breast bracket group were 6.10 mm, 6.34 mm, and 6.10 mm, respectively. Moreover, the PTV margins of the supraclavicular target in the three directions were 3.69 mm, 3.86 mm, and 4.28 mm in the Styrofoam group, while those in the breast bracket group were 3.99 mm, 3.72 mm, and 5.45 mm, respectively. The setup time of the two groups was 3.4 ± 1.1 min and 5.5 ± 3.1 min (P = 0.007). The subjective comfort satisfaction scores of the two groups were 27.50 ± 1.24 and 25.44 ± 1.23 (P < 0.001). CONCLUSIONS The application of Styrofoam fixation in radiotherapy of breast cancer in the supraclavicular lymph node area has several advantages as compared to breast bracket fixation, including higher positioning accuracy, smaller external expansion boundary, improved work efficiency, and patients' comfort, which might provide a reference for clinical work.
Collapse
Affiliation(s)
- Jie Li
- Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University. Xi’an, China
| | - Lin Yang
- Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University. Xi’an, China
| | - Xiaowei Yao
- Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University. Xi’an, China
| | - Linlin Xu
- Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University. Xi’an, China
| | - Lina Zhao
- Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University. Xi’an, China
| | - Fei Bai
- Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University. Xi’an, China
| |
Collapse
|
4
|
Hoffmann L, Ehmsen ML, Hansen J, Hansen R, Knap MM, Mortensen HR, Poulsen PR, Ravkilde T, Rose HK, Schmidt HH, Worm ES, Møller DS. Repeated deep-inspiration breath-hold CT scans at planning underestimate the actual motion between breath-holds at treatment for lung cancer and lymphoma patients. Radiother Oncol 2023; 188:109887. [PMID: 37659663 DOI: 10.1016/j.radonc.2023.109887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Revised: 08/04/2023] [Accepted: 08/23/2023] [Indexed: 09/04/2023]
Abstract
PURPOSE/OBJECTIVE Deep-inspiration breath-hold (DIBH) during radiotherapy may reduce dose to the lungs and heart compared to treatment in free breathing. However, intra-fractional target shifts between several breath-holds may decrease target coverage. We compared target shifts between four DIBHs at the planning-CT session with those measured on CBCT-scans obtained pre- and post-DIBH treatments. MATERIAL/METHODS Twenty-nine lung cancer and nine lymphoma patients were treated in DIBH. An external gating block was used as surrogate for the DIBH-level with a window of 2 mm. Four DIBH CT-scans were acquired: one for planning (CTDIBH3) and three additional (CTDIBH1,2,4) to assess the intra-DIBH target shifts at scanning by registration to CTDIBH3. During treatment, pre-treatment (CBCTpre) and post-treatment (CBCTpost) scans were acquired. For each pair of CBCTpre/post, the target intra-DIBH shift was determined. For lung cancer, tumour (GTV-Tlung) and lymph nodes (GTV-Nlung) were analysed separately. Group mean (GM), systematic and random errors, and GM for the absolute maximum shifts (GMmax) were calculated for the shifts between CTDIBH1,2,3,4 and between CBCTpre/post. RESULTS For GTV-Tlung, GMmax was larger at CBCT than CT in all directions. GMmax in cranio-caudal direction was 3.3 mm (CT)and 6.1 mm (CBCT). The standard deviations of the shifts in the left-right and cranio-caudal directions were larger at CBCT than CT. For GTV-Nlung and CTVlymphoma, no difference was found in GMmax or SD. CONCLUSION Intra-DIBH shifts at planning-CT session are generally smaller than intra-DIBH shifts observed at CBCTpre/post and therefore underestimate the intra-fractional DIBH uncertainty during treatment. Lung tumours show larger intra-fractional variations than lymph nodes and lymphoma targets.
Collapse
Affiliation(s)
- Lone Hoffmann
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
| | - M L Ehmsen
- Danish Center for Proton Therapy, Aarhus University Hospital, Aarhus, Denmark
| | - J Hansen
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark
| | - R Hansen
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark
| | - M M Knap
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark
| | - H R Mortensen
- Danish Center for Proton Therapy, Aarhus University Hospital, Aarhus, Denmark
| | - P R Poulsen
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; Danish Center for Proton Therapy, Aarhus University Hospital, Aarhus, Denmark
| | - T Ravkilde
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark
| | - H K Rose
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark
| | - H H Schmidt
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark
| | - E S Worm
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark
| | - D S Møller
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
5
|
Psarras M, Stasinou D, Stroubinis T, Protopapa M, Zygogianni A, Kouloulias V, Platoni K. Surface-Guided Radiotherapy: Can We Move on from the Era of Three-Point Markers to the New Era of Thousands of Points? Bioengineering (Basel) 2023; 10:1202. [PMID: 37892932 PMCID: PMC10604452 DOI: 10.3390/bioengineering10101202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/10/2023] [Accepted: 10/14/2023] [Indexed: 10/29/2023] Open
Abstract
The surface-guided radiotherapy (SGRT) technique improves patient positioning with submillimeter accuracy compared with the conventional positioning technique of lasers using three-point tattoos. SGRT provides solutions to considerations that arise from the conventional setup technique, such as variability in tattoo position and the psychological impact of the tattoos. Moreover, SGRT provides monitoring of intrafractional motion. PURPOSE This literature review covers the basics of SGRT systems and examines whether SGRT can replace the traditional positioning technique. In addition, it investigates SGRT's potential in reducing positioning times, factors affecting SGRT accuracy, the effectiveness of live monitoring, and the impact on patient dosage. MATERIALS AND METHODS This study focused on papers published from 2016 onward that compared SGRT with the traditional positioning technique and investigated factors affecting SGRT accuracy and effectiveness. RESULTS/CONCLUSIONS SGRT provides the same or better results regarding patient positioning. The implementation of SGRT can reduce overall treatment time. It is an effective technique for detecting intrafraction patient motion, improving treatment accuracy and precision, and creating a safe and comfortable environment for the patient during treatment.
Collapse
Affiliation(s)
- Michalis Psarras
- Medical Physics Unit, 2nd Department of Radiology, Attikon University Hospital, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece
- Department of Radiation Oncology and Stereotactic Radiosurgery, Mediterraneo Hospital, 166 75 Athens, Greece
| | - Despoina Stasinou
- Department of Radiation Oncology and Stereotactic Radiosurgery, Mediterraneo Hospital, 166 75 Athens, Greece
| | - Theodoros Stroubinis
- Department of Radiation Oncology and Stereotactic Radiosurgery, Mediterraneo Hospital, 166 75 Athens, Greece
| | - Maria Protopapa
- Department of Radiation Oncology and Stereotactic Radiosurgery, Mediterraneo Hospital, 166 75 Athens, Greece
| | - Anna Zygogianni
- Radiation Oncology Unit, 1st Department of Radiology, Aretaieion University Hospital, Medical School, National and Kapodistrian University of Athens, 115 28 Athens, Greece
| | - Vassilis Kouloulias
- Radiation Oncology Unit, 2nd Department of Radiology, Attikon University Hospital, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece
| | - Kalliopi Platoni
- Medical Physics Unit, 2nd Department of Radiology, Attikon University Hospital, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece
- Department of Radiation Oncology and Stereotactic Radiosurgery, Mediterraneo Hospital, 166 75 Athens, Greece
| |
Collapse
|
6
|
Beddok A, Lim R, Thariat J, Shih HA, El Fakhri G. A Comprehensive Primer on Radiation Oncology for Non-Radiation Oncologists. Cancers (Basel) 2023; 15:4906. [PMID: 37894273 PMCID: PMC10605284 DOI: 10.3390/cancers15204906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 10/05/2023] [Accepted: 10/07/2023] [Indexed: 10/29/2023] Open
Abstract
Background: Multidisciplinary management is crucial in cancer diagnosis and treatment. Multidisciplinary teams include specialists in surgery, medical therapies, and radiation therapy (RT), each playing unique roles in oncology care. One significant aspect is RT, guided by radiation oncologists (ROs). This paper serves as a detailed primer for non-oncologists, medical students, or non-clinical investigators, educating them on contemporary RT practices. Methods: This report follows the process of RT planning and execution. Starting from the decision-making in multidisciplinary teams to the completion of RT and subsequent patient follow-up, it aims to offer non-oncologists an understanding of the RO's work in a comprehensive manner. Results: The first step in RT is a planning session that includes obtaining a CT scan of the area to be treated, known as the CT simulation. The patients are imaged in the exact position in which they will receive treatment. The second step, which is the primary source of uncertainty, involves the delineation of treatment targets and organs at risk (OAR). The objective is to ensure precise irradiation of the target volume while sparing the OARs as much as possible. Various radiation modalities, such as external beam therapy with electrons, photons, or particles (including protons and carbon ions), as well as brachytherapy, are utilized. Within these modalities, several techniques, such as three-dimensional conformal RT, intensity-modulated RT, volumetric modulated arc therapy, scattering beam proton therapy, and intensity-modulated proton therapy, are employed to achieve optimal treatment outcomes. The RT plan development is an iterative process involving medical physicists, dosimetrists, and ROs. The complexity and time required vary, ranging from an hour to a week. Once approved, RT begins, with image-guided RT being standard practice for patient alignment. The RO manages acute toxicities during treatment and prepares a summary upon completion. There is a considerable variance in practices, with some ROs offering lifelong follow-up and managing potential late effects of treatment. Conclusions: Comprehension of RT clinical effects by non-oncologists providers significantly elevates long-term patient care quality. Hence, educating non-oncologists enhances care for RT patients, underlining this report's importance.
Collapse
Affiliation(s)
- Arnaud Beddok
- Department of Radiation Oncology, Institut Godinot, 51100 Reims, France
- Gordon Center for Medical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Ruth Lim
- Gordon Center for Medical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Juliette Thariat
- Department of Radiation Oncology, Centre François-Baclesse, 14000 Caen, France
| | - Helen A. Shih
- Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Georges El Fakhri
- Gordon Center for Medical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| |
Collapse
|
7
|
Brennsæter JA, Dahle TJ, Moi JN, Svanberg IF, Haaland GS, Pilskog S. Reduction of PTV margins for elective pelvic lymph nodes in online adaptive radiotherapy of prostate cancer patients. Acta Oncol 2023; 62:1208-1214. [PMID: 37682727 DOI: 10.1080/0284186x.2023.2252584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 08/22/2023] [Indexed: 09/10/2023]
Abstract
BACKGROUND Cone beam CT (CBCT) based online adaptive radiotherapy (oART) is a new development in radiotherapy. With oART, the requirements for planning target volume (PTV) margins differ from standard therapy because motion occurs during a session. In this study, we aim to evaluate a margin reduction for locally advanced prostate patients treated with oART. MATERIAL AND METHODS Intrafraction motion of the elective pelvic lymph nodes was evaluated by two radiation therapists (RTTs) for 150 fractions from 10 prostate patients treated with oART. PTV margins of 3, 4 and 5 mm where added to these lymph nodes for all patients. The seven first patients were treated with 5 mm PTV margin, while the last three patients were treated with 4 mm margin. After treatment, the RTTs reviewed the verification CBCTs and evaluated whether the various PTV margins would have covered the adapted clinical target volume, scoring each fraction as approved, inconclusive or rejected. Couch shifts corresponding to the rigid prostate match between the CBCTs were analyzed with respect to the RTT evaluation. RESULTS The RTTs approved a 4 mm margin in 95% of the fractions, while 2% of the fractions were rejected. For a 3 mm margin, 57% of the fractions were approved, while 5% were rejected. The scoring from the two RTTs was consistent; e.g., for 3 mm, one RTT approved 58% of the fractions, while the other approved 55%. If the couch was moved less than 2 mm in any direction, 70% of the fractions were approved for a 3 mm margin, compared to 32% for shifts greater than 2 mm. CONCLUSION It is safe to reduce the PTV margin from 5 to 4 mm for the elective pelvic lymph nodes for prostate patients treated with oART. Further margin reductions can be motivated for patients presenting little intrafraction motion.
Collapse
Affiliation(s)
- John Alfred Brennsæter
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway
| | - Tordis Johnsen Dahle
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway
| | - Jannicke Nøkling Moi
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway
| | | | - Gry Sandvik Haaland
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway
| | - Sara Pilskog
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| |
Collapse
|
8
|
Sasaki M, Matsushita N, Fujimoto T, Nakata M, Ono Y, Yoshimura M, Mizowaki T. New patient setup procedure using surface-guided imaging to reduce body touch and skin marks in whole-breast irradiation during the COVID-19 pandemic. Radiol Phys Technol 2023; 16:422-429. [PMID: 37474738 DOI: 10.1007/s12194-023-00735-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 07/14/2023] [Accepted: 07/15/2023] [Indexed: 07/22/2023]
Abstract
This study aimed to assess the effectiveness of a new patient-setup procedure using surface-guided imaging during the coronavirus disease 2019 (COVID-19) pandemic for left-sided whole-breast irradiation with deep inspiration breath-hold. Two setup procedures were compared regarding patient positioning accuracy for the first 22 patients. The first was a traditional setup (T-setup) procedure that used a surface-guided system after patient setup with traditional skin marks and lasers. The second procedure involved a new setup (N-setup) that used only a surface-guided system. The positioning accuracy of the remaining 23 patients was assessed using a setup that combined marker reduction and the N-setup procedure. No significant difference was observed in positioning accuracy between the two setups. The positioning accuracy of the marker-reduction setup was within 3 mm in all directions. The N-setup procedure may be a useful strategy for preventing infection during or after the COVID-19 pandemic.
Collapse
Affiliation(s)
- Makoto Sasaki
- Division of Clinical Radiology Service, Kyoto University Hospital, 54 Kawahara-Cho, Shogoin, Sakyo-Ku, Kyoto, Kyoto, 606-8507, Japan.
| | - Norimasa Matsushita
- Division of Clinical Radiology Service, Kyoto University Hospital, 54 Kawahara-Cho, Shogoin, Sakyo-Ku, Kyoto, Kyoto, 606-8507, Japan
| | - Takahiro Fujimoto
- Division of Clinical Radiology Service, Kyoto University Hospital, 54 Kawahara-Cho, Shogoin, Sakyo-Ku, Kyoto, Kyoto, 606-8507, Japan
| | - Manabu Nakata
- Division of Clinical Radiology Service, Kyoto University Hospital, 54 Kawahara-Cho, Shogoin, Sakyo-Ku, Kyoto, Kyoto, 606-8507, Japan
| | - Yuka Ono
- Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Michio Yoshimura
- Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Takashi Mizowaki
- Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| |
Collapse
|
9
|
Lee J, Kim YJ, Goh Y, Yang E, Kim HU, Song SY, Kim YS. Application of surface-guided radiation therapy in prostate cancer: comparative analysis of differences with skin marking-guided patient setup. Radiat Oncol J 2023; 41:172-177. [PMID: 37793626 PMCID: PMC10556842 DOI: 10.3857/roj.2023.00521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 08/10/2023] [Accepted: 08/23/2023] [Indexed: 10/06/2023] Open
Abstract
PURPOSE Surface-guided radiation therapy is an image-guided method using optical surface imaging that has recently been adopted for patient setup and motion monitoring during treatment. We aimed to determine whether the surface guide setup is accurate and efficient compared to the skin-marking guide in prostate cancer treatment. MATERIALS AND METHODS The skin-marking setup was performed, and vertical, longitudinal, and lateral couch values (labeled as "M") were recorded. Subsequently, the surface-guided setup was conducted, and couch values (labeled as "S") were recorded. After performing cone-beam computed tomography (CBCT), the final couch values was recorded (labeled as "C"), and the shift value was calculated (labeled as "Gap (M-S)," "Gap (M-C)," "Gap (S-C)") and then compared. Additionally, the setup times for the skin marking and surface guides were also compared. RESULTS One hundred and twenty-five patients were analyzed, totaling 2,735 treatment fractions. Gap (M-S) showed minimal differences in the vertical, longitudinal, and lateral averages (-0.03 cm, 0.07 cm, and 0.06 cm, respectively). Gap (M-C) and Gap (S-C) exhibited a mean difference of 0.04 cm (p = 0.03) in the vertical direction, a mean difference of 0.35 cm (p = 0.52) in the longitudinal direction, and a mean difference of 0.11 cm (p = 0.91) in the lateral direction. There was no correlation between shift values and patient characteristics. The average setup time of the skin-marking guide was 6.72 minutes, and 7.53 minutes for the surface guide. CONCLUSION There was no statistically significant difference between the surface and skin-marking guides regarding final CBCT shift values and no correlation between translational shift values and patient characteristics. We also observed minimal difference in setup time between the two methods. Therefore, the surface guide can be considered an accurate and time-efficient alternative to skin-marking guides.
Collapse
Affiliation(s)
- Jaeha Lee
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Yeon Joo Kim
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Youngmoon Goh
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Eunyeong Yang
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Ha Un Kim
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Si Yeol Song
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Young Seok Kim
- Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
10
|
Nielsen AWM, Spejlborg H, Lutz CM, Rugaard Poulsen P, Offersen BV. Difference between planned and delivered radiotherapy dose to the internal mammary nodes in high-risk breast cancer patients. Phys Imaging Radiat Oncol 2023; 27:100470. [PMID: 37533551 PMCID: PMC10393587 DOI: 10.1016/j.phro.2023.100470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 07/05/2023] [Accepted: 07/06/2023] [Indexed: 08/04/2023] Open
Abstract
Background and purpose Chest wall movement during radiotherapy can impact the delivered dose to the internal mammary nodes (IMN) in high-risk breast cancer patients. Using portal imaging and dose reconstruction we aimed to examine the delivered IMN dose coverage. Material and methods Cine MV images were recorded for 39 breast cancer patients treated with daily image-guided radiotherapy (IGRT) in deep-inspiration breath-hold (DIBH). On the final frame of each cine MV recording the chest wall was matched with the Digitally Reconstructed Radiograph (DRR) from the treatment plan. The geometrical chest wall error was determined in the imager-plane perpendicular to the cranio-caudal direction, rounded to integer millimeters, and binned. For each 1 mm bin, an isocenter-shifted treatment plan was recalculated assuming that the projected error observed in the cine MV image was caused by anterior-posterior chest wall movement in the IMN region. A weighted plan sum yielded the IMN clinical target volume receiving at least 90% dose (V90_CTVn_IMN). Results The mean number of cine MV observations per patient was 36 (range 26-55). Most patients (67%) had on average a posterior chest wall position at treatment compared to planned. This translated into a change in the delivered median V90_CTVn_IMN of -0.7% (range, -11.9-2.9%; p < 0.001). The V90_CTVn_IMN reduction was greater than 9% in three patients. No clinically relevant differences were found for the mean lung dose or mean heart dose. Conclusion Using cine MV images, we found that the delivered V90_CTVn_IMN was significantly lower than planned. In 8% of the patients, the V90_CTVn_IMN reduction exceeded 9%.
Collapse
Affiliation(s)
| | - Harald Spejlborg
- Department of Medical Physics, Aarhus University Hospital, Aarhus, Denmark
| | | | - Per Rugaard Poulsen
- Danish Center for Particle Therapy, Aarhus University Hospital, Denmark
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark
| | - Birgitte Vrou Offersen
- Department of Experimental Clinical Oncology, Aarhus University Hospital, Aarhus, Denmark
- Danish Center for Particle Therapy, Aarhus University Hospital, Denmark
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
11
|
Nikovia V, Chinis E, Gkantaifi A, Marketou M, Mazonakis M, Charalampakis N, Mavroudis D, Orfanidou KV, Varveris A, Antoniadis C, Tolia M. Current Cardioprotective Strategies for the Prevention of Radiation-Induced Cardiotoxicity in Left-Sided Breast Cancer Patients. J Pers Med 2023; 13:1038. [PMID: 37511651 PMCID: PMC10381791 DOI: 10.3390/jpm13071038] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 05/11/2023] [Accepted: 06/20/2023] [Indexed: 07/30/2023] Open
Abstract
BACKGROUND Breast cancer (BC) is the most common malignancy in females, accounting for the majority of cancer-related deaths worldwide. There is well-established understanding about the effective role of radiotherapy (RT) in BC therapeutic strategies, offering a better local-regional control, prolonged survival, and improved quality of life for patients. However, it has been proven that conventional RT modalities, especially in left-sided BC cases, are unable to avoid the administration of high RT doses to the heart, thus resulting in cardiotoxicity and promoting long-term cardiovascular diseases (CVD). Recent radiotherapeutic techniques, characterized by dosimetric dose restrictions, target volume revision/modifications, an increased awareness of risk factors, and consistent follow-ups, have created an advantageous context for a significant decrease inpost-RT CVD incidence. AIM This review presents the fundamental role of current cardioprotective strategies in the prevention of cardiotoxic effects in left-BCRT. MATERIAL AND METHODS A literature search was conducted up to January 2023 using the Cochrane Central Register of Controlled Trials and PubMed Central databases. Our review refers to new radiotherapeutic techniques carried out on patients after BC surgery. Specifically, a dose evaluation of the heart and left anterior descending coronary artery (LADCA) was pointed out for all the included studies, depending on the implemented RT modality, bed positioning, and internal mammary lymph nodes radiation. RESULTS Several studies reporting improved heart sparing with new RT techniques in BC patients were searched. In addition to the RT modality, which definitely determines the feasibility of achieving lower doses for the organs at risk (OARs), better target coverage, dose conformity and homogeneity, and the patient's position, characteristics, and anatomy may also affect the evaluated RT dose to the whole heart and its substructures. CONCLUSIONS Modern BC RT techniques seem to enable the administration of lower doses to the OARs without compromising on the target coverage. The analysis of several anatomical parameters and the assessment of cardiac biomarkers potentiate the protective effect of these new irradiation modalities, providing a holistic approach to the radiation-associated risks of cardiac disease for BC patients. Despite technological advances, an inevitable cardiac radiation risk still exists, while adverse cardiac events may be observed even many years after RT. Studies with longer follow-ups are required in order to determine the effectiveness of modern breast RT techniques.
Collapse
Affiliation(s)
- Vasiliki Nikovia
- Medical School, University of Crete, Vassilika, 71110 Heraklion, Greece
| | - Evangelos Chinis
- Medical School, University of Crete, Vassilika, 71110 Heraklion, Greece
| | - Areti Gkantaifi
- Radiotherapy Department, Theagenio Anticancer Hospital of Thessaloniki, 54639 Thessaloniki, Greece
| | - Maria Marketou
- Cardiology Department, University General Hospital of Heraklion, Heraklion, 71110 Heraklion, Greece
| | - Michalis Mazonakis
- Department of Medical Physics, Faculty of Medicine, University of Cret, Iraklion, P.O. Box 2208, 71003 Heraklion, Greece
| | | | - Dimitrios Mavroudis
- Department of Medical Oncology, University General Hospital of Heraklion, 71500 Heraklion, Greece
| | | | - Antonios Varveris
- Department of Radiotherapy, University Hospital/Medical School, University of Crete, Vassilika, 71110 Heraklion, Greece
| | - Chrysostomos Antoniadis
- Department of Radiotherapy, University Hospital/Medical School, University of Crete, Vassilika, 71110 Heraklion, Greece
| | - Maria Tolia
- Department of Radiotherapy, University Hospital/Medical School, University of Crete, Vassilika, 71110 Heraklion, Greece
| |
Collapse
|
12
|
Crockett C, Lorimer C. OncoFlash January 2023. Clin Oncol (R Coll Radiol) 2023; 35:3-5. [PMID: 36586727 DOI: 10.1016/j.clon.2022.12.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- C Crockett
- Northern Ireland Cancer Centre, Belfast City Hospital, Belfast, UK
| | - C Lorimer
- University Hospitals Sussex NHS Foundation Trust, West Sussex, UK
| |
Collapse
|