• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4611068)   Today's Articles (16)   Subscriber (49381)
For: Costa P, Vieira D, Naccache V, Ferreira K, Priszkulnik S. Evaluation of X-ray spectra transmitted by different concrete compositions. Radiat Phys Chem Oxf Engl 1993 2015;116:349-54. [DOI: 10.1016/j.radphyschem.2015.03.040] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Number Cited by Other Article(s)
1
Tyagi G, Singhal A, Routroy S, Bhunia D, Lahoti M. Radiation Shielding Concrete with alternate constituents: An approach to address multiple hazards. JOURNAL OF HAZARDOUS MATERIALS 2021;404:124201. [PMID: 33129018 DOI: 10.1016/j.jhazmat.2020.124201] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 09/11/2020] [Accepted: 10/04/2020] [Indexed: 06/11/2023]
2
Frimaio A, Nascimento BC, Barrio RM, Campos LL, Costa PR. Reprint of “X-ray spectrometry applied for determination of linear attenuation coefficient of tissue-equivalent materials”. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2019.108553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
3
Frimaio A, Nascimento BC, Barrio RM, Campos LL, Costa PR. X-ray spectrometry applied for determination of linear attenuation coefficient of tissue-equivalent materials. Radiat Phys Chem Oxf Engl 1993 2019. [DOI: 10.1016/j.radphyschem.2019.03.021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
4
Bourgois L, Ménard S. Dose equivalent transmission data for shielding industrial x-ray facilities up to 800 kV. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2018;38:471-479. [PMID: 29424360 DOI: 10.1088/1361-6498/aaae20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
PrevPage 1 of 1 1Next