1
|
Ma L, Ma C, Chen G, Gu J, Yang T, Li L, Gao H, Xiong Y, Wu Y, Zhu C, Zhou Y, Hu A, Chen K, Liu Z. Nitrogen and Sulfur co-doped Carbon dots as an "on-off-on" Fluorescent Sensor for the Detection of Hg 2+ and Ampicillin. J Fluoresc 2024:10.1007/s10895-024-03656-2. [PMID: 38457076 DOI: 10.1007/s10895-024-03656-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Accepted: 03/01/2024] [Indexed: 03/09/2024]
Abstract
Herein, a fluorescent "on-off-on" nanosensor based on N,S-CDs was developed for highly precise and sensitive recognition of Hg2+ and ampicillin (AMP). Nitrogen and sulfur co-doped carbon dots with blue fluorescence were synthesized by one-pot hydrothermal method using ammonium citrate and DL-methionine as precursors. N,S-CDs exhibited a surface abundant in -OH, -COOH, and -NH2 groups, aiding in creating non-fluorescent ground state complexes when combined with Hg2+, leading to the suppression of N,S-CDs' fluorescence. Subsequent to additional AMP application, the mixed system's fluorescence was restored. Based on this N,S-CDs sensing system, the thresholds for detection for AMP and Hg2+ were discovered to be 0.121 µM and 0.493 µM, respectively. Furthermore, this methodology proved effective in identifying AMP in real samples of tap and lake water, yielding satisfactory results. Consequently, in the area of bioanalysis in intricate environmental sample work, the sensing system showed tremendous promise.
Collapse
Affiliation(s)
- LongYao Ma
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| | - ChaoQun Ma
- School of Science, Jiangnan University, Wuxi, 214122, China.
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China.
| | - GuoQing Chen
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| | - Jiao Gu
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| | - Taiqun Yang
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| | - Lei Li
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| | - Hui Gao
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| | - Yi Xiong
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| | - Yamin Wu
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| | - Chun Zhu
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| | - Yan Zhou
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| | - Anqi Hu
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| | - Kun Chen
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| | - ZhaoChen Liu
- School of Science, Jiangnan University, Wuxi, 214122, China
- Jiangsu Provincial Research Center of Light Industrial optoelectronic engineering and Technology, Wuxi, 214122, China
| |
Collapse
|
2
|
Feghhi F, Minagar A, Madaah Hosseini HR. Bandgap tailoring and enhancing the aromatization in cysteine-based carbon dots. J Colloid Interface Sci 2023; 651:36-46. [PMID: 37540928 DOI: 10.1016/j.jcis.2023.07.157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 07/14/2023] [Accepted: 07/24/2023] [Indexed: 08/06/2023]
Abstract
Cysteine, as a non-aromatic precursor, was used to produce Nitrogen (N) and Sulfur (S) sources for preparing N, S-doped carbon dots (CDs) with tunable luminescence emission. Despite the tremendous investigations, the photoluminescence (PL) mechanism of CDs is still unclear due to its complex core-shell structure, variety of surface functional groups, and structure dependency. This study focuses on controlling aromatization and graphitization processes during the hydrothermal synthesis on CDs by using Citric Acid (CA) and Ammonium persulfate. Detailed characterizations by FTIR spectroscopy, XPS, and HR-TEM are provided to suggest both chemical and bandgap structures. Results reveal that the red-shift of PL occurred due to the graphitization and increasing content of graphitic nitrogen in the core, as well as the Pyridinic and Amine groups creating sub-bands on the surface. These findings resolve the controversy on the PL mechanism of Cysteine-based CDs and provide a general guide for increasing the aromatization and graphitization degree from non-aromatic precursors which clarify the mechanism exploration and structural analysis of other types of CDs.
Collapse
Affiliation(s)
- Fazeleh Feghhi
- epartment of Materials Science and Engineering, Sharif University of Technology, Azadi Avenue, P.O. Box 11155-9466, Tehran, Iran
| | - Ava Minagar
- epartment of Materials Science and Engineering, Sharif University of Technology, Azadi Avenue, P.O. Box 11155-9466, Tehran, Iran
| | - H R Madaah Hosseini
- epartment of Materials Science and Engineering, Sharif University of Technology, Azadi Avenue, P.O. Box 11155-9466, Tehran, Iran; Institute for Convergence Science & Technology, Center for Bioscience & Technology, Sharif University of Technology, Tehran 1458889694, Iran.
| |
Collapse
|
3
|
Peng G, Guo M, Liu Y, Yang H, Wen Z, Chen X. Development of a Novel H-Shaped Electrochemical Aptasensor for Detection of Hg 2+ Based on Graphene Aerogels-Au Nanoparticles Composite. BIOSENSORS 2023; 13:932. [PMID: 37887125 PMCID: PMC10605725 DOI: 10.3390/bios13100932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Revised: 09/22/2023] [Accepted: 10/16/2023] [Indexed: 10/28/2023]
Abstract
Hg2+, a highly toxic heavy metal, poses significant environmental and health risks, necessitating rapid detection methods. In this study, we employed an electrochemical aptasensor for rapid and sensitive detection of Hg2+ based on DNA strands (H2 and H3) immobilized graphene aerogels-Au nanoparticles (GAs-AuNPs) hybrid recognition interface and exonuclease III (Exo III)-mediated cyclic amplification. Firstly, Gas-AuNPs were modified on the surface of the ITO electrode to form a sensing interface to increase DNA loading and accelerate electron transfer. Then, DNA helper was generated with the addition of Hg2+ via Exo III-mediated cycling. Finally, the hairpin structures of H2 and H3 were opened with the DNA helper, and then the methylene blue (MB) functionalized DNA (A1 and A2) combined with the H2 and H3 to form an H-shaped structure. The current response of MB as an electrochemical probe was proportional to the concentration of Hg2+. Under optimal conditions, the aptasensor showed excellent performance for Hg2+, achieving a linear range from 1 fM to 10 nM and a detection limit of 0.16 fM. Furthermore, the aptasensor was used to detect Hg2+ in spiked milk samples, achieving a high recovery rate and demonstrating promising application prospects.
Collapse
Affiliation(s)
- Gang Peng
- College of Food Engineering, Anhui Science and Technology University, Fengyang 233100, China; (M.G.); (Y.L.); (H.Y.); (Z.W.)
| | - Mengxue Guo
- College of Food Engineering, Anhui Science and Technology University, Fengyang 233100, China; (M.G.); (Y.L.); (H.Y.); (Z.W.)
| | - Yuting Liu
- College of Food Engineering, Anhui Science and Technology University, Fengyang 233100, China; (M.G.); (Y.L.); (H.Y.); (Z.W.)
| | - Han Yang
- College of Food Engineering, Anhui Science and Technology University, Fengyang 233100, China; (M.G.); (Y.L.); (H.Y.); (Z.W.)
| | - Zuorui Wen
- College of Food Engineering, Anhui Science and Technology University, Fengyang 233100, China; (M.G.); (Y.L.); (H.Y.); (Z.W.)
| | - Xiaojun Chen
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing 211816, China;
| |
Collapse
|
4
|
Alhazzani K, Alanazi AZ, Mostafa AM, Barker J, El-Wekil MM, Bellah H Ali AM. A selective dual quenching sensor (EY/BG@CDs) for simultaneous monitoring of gentamicin and ketorolac levels in plasma: a highly efficient platform that caters to the needs of therapeutic drug monitoring. RSC Adv 2023; 13:28940-28950. [PMID: 37795051 PMCID: PMC10545982 DOI: 10.1039/d3ra04894b] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 09/23/2023] [Indexed: 10/06/2023] Open
Abstract
This research work introduces a novel sensor that utilizes two fluorophores to enable simultaneous monitoring of gentamicin sulphate (GNT) and ketorolac tromethamine (KET). The innovative sensor is composed of carbon dots (CDs) derived from black grapes (BG) and eosin Y (EY) dye. The interaction between the studied drugs and EY/BG@CDs sensor components allows for their simultaneous detection where GNT quenches the fluorescence of EY at 535 nm without affecting the fluorescence of CDs, while KET quenches the fluorescence of BG@CDs at 385 nm without impacting EY fluorescence. The BG@CDs probe was successfully characterized using various techniques such as absorption spectrophotometry, spectrofluorimetry, TEM imaging, infrared spectroscopic analysis, and XRD analysis. The suggested methodology was observed to be highly sensitive for the simultaneous determination of GNT and KET in their spiked rabbit plasma samples, with wide linear ranges and low limit of detection (LOD) values. The studied drugs were extracted using a highly selective extraction method involving protein precipitation followed by mixed mode solid phase extraction using an Oasis WCX cartridge. The simultaneous determination of GNT and KET is essential due to the potential interactions between the studied drugs. Therefore, this analysis can be used to evaluate the necessity of dose monitoring and the potential adverse effects of co-administration of these drugs.
Collapse
Affiliation(s)
- Khalid Alhazzani
- Department of Pharmacology and Toxicology, College of Pharmacy, King Saud University Riyadh Saudi Arabia
| | - Ahmed Z Alanazi
- Department of Pharmacology and Toxicology, College of Pharmacy, King Saud University Riyadh Saudi Arabia
| | - Aya M Mostafa
- School of Life Sciences, Pharmacy, and Chemistry, Kingston University Kingston-upon-Thames London KT1 2EE UK
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University Assiut Egypt
| | - James Barker
- School of Life Sciences, Pharmacy, and Chemistry, Kingston University Kingston-upon-Thames London KT1 2EE UK
| | - Mohamed M El-Wekil
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University Assiut Egypt
| | - Al-Montaser Bellah H Ali
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University Assiut Egypt
| |
Collapse
|
5
|
Kumar A. Recent Development in Fluorescent Probes for the Detection of Hg 2+ Ions. Crit Rev Anal Chem 2023; 54:3269-3312. [PMID: 37517076 DOI: 10.1080/10408347.2023.2238066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/01/2023]
Abstract
Mercury, a highly toxic heavy metal, poses significant environmental and health risks, necessitating the development of effective and responsive techniques for its detection. Organic chromophores, particularly small molecules, have emerged as promising materials for sensing Hg2+ ions due to their high selectivity, sensitivity, and ease of synthesis. In this review article, we provide a systematic overview of recent advancements in the field of fluorescent chemosensors for Hg2+ ions detection, including rhodamine derivatives, Schiff bases, coumarin derivatives, naphthalene derivatives, BODIPY, BOPHY, naphthalimide, pyrene, dicyanoisophorone, bromophenol, benzothiazole flavonol, carbonitrile, pyrazole, quinoline, resorufin, hemicyanine, monothiosquaraine, cyanine, pyrimidine, peptide, and quantum/carbon dots probes. We discuss their detection capabilities, sensing mechanisms, limits of detection, as well as the strategies and approaches employed in their design. By focusing on recent studies conducted between 2022 and 2023, this review article offers valuable insights into the performance and advancements in the field of fluorescent chemosensors for Hg2+ ions detection.
Collapse
Affiliation(s)
- Ajay Kumar
- Department of Chemistry, D.B.S. (PG) College Dehradun, Uttarakhand, India
| |
Collapse
|