1
|
Tang WS, Zhong ED, Hanson SM, Thiede EH, Cossio P. Conformational heterogeneity and probability distributions from single-particle cryo-electron microscopy. Curr Opin Struct Biol 2023; 81:102626. [PMID: 37311334 DOI: 10.1016/j.sbi.2023.102626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 04/25/2023] [Accepted: 05/16/2023] [Indexed: 06/15/2023]
Abstract
Single-particle cryo-electron microscopy (cryo-EM) is a technique that takes projection images of biomolecules frozen at cryogenic temperatures. A major advantage of this technique is its ability to image single biomolecules in heterogeneous conformations. While this poses a challenge for data analysis, recent algorithmic advances have enabled the recovery of heterogeneous conformations from the noisy imaging data. Here, we review methods for the reconstruction and heterogeneity analysis of cryo-EM images, ranging from linear-transformation-based methods to nonlinear deep generative models. We overview the dimensionality-reduction techniques used in heterogeneous 3D reconstruction methods and specify what information each method can infer from the data. Then, we review the methods that use cryo-EM images to estimate probability distributions over conformations in reduced subspaces or predefined by atomistic simulations. We conclude with the ongoing challenges for the cryo-EM community.
Collapse
Affiliation(s)
- Wai Shing Tang
- Center for Computational Mathematics, Flatiron Institute, 162 5th Ave, New York, NY, 10010, United States. https://twitter.com/WaiShingTang
| | - Ellen D Zhong
- Department of Computer Science, Princeton University, 35 Olden St, Princeton, NJ, 08544, United States. https://twitter.com/ZhongingAlong
| | - Sonya M Hanson
- Center for Computational Mathematics, Flatiron Institute, 162 5th Ave, New York, NY, 10010, United States; Center for Computational Biology, Flatiron Institute, 162 5th Ave, New York, NY, 10010, United States. https://twitter.com/sonyahans
| | - Erik H Thiede
- Center for Computational Mathematics, Flatiron Institute, 162 5th Ave, New York, NY, 10010, United States. https://twitter.com/erik_der_elch
| | - Pilar Cossio
- Center for Computational Mathematics, Flatiron Institute, 162 5th Ave, New York, NY, 10010, United States; Center for Computational Biology, Flatiron Institute, 162 5th Ave, New York, NY, 10010, United States.
| |
Collapse
|
2
|
Toader B, Sigworth FJ, Lederman RR. Methods for Cryo-EM Single Particle Reconstruction of Macromolecules Having Continuous Heterogeneity. J Mol Biol 2023; 435:168020. [PMID: 36863660 PMCID: PMC10164696 DOI: 10.1016/j.jmb.2023.168020] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 02/15/2023] [Accepted: 02/16/2023] [Indexed: 03/02/2023]
Abstract
Macromolecules change their shape (conformation) in the process of carrying out their functions. The imaging by cryo-electron microscopy of rapidly-frozen, individual copies of macromolecules (single particles) is a powerful and general approach to understanding the motions and energy landscapes of macromolecules. Widely-used computational methods already allow the recovery of a few distinct conformations from heterogeneous single-particle samples, but the treatment of complex forms of heterogeneity such as the continuum of possible transitory states and flexible regions remains largely an open problem. In recent years there has been a surge of new approaches for treating the more general problem of continuous heterogeneity. This paper surveys the current state of the art in this area.
Collapse
Affiliation(s)
- Bogdan Toader
- Department of Statistics and Data Science, Yale University, United States.
| | - Fred J Sigworth
- Department of Cellular and Molecular Physiology, Yale University, United States
| | - Roy R Lederman
- Department of Statistics and Data Science, Yale University, United States. https://twitter.com/roylederman
| |
Collapse
|
3
|
DeVore K, Chiu PL. Probing Structural Perturbation of Biomolecules by Extracting Cryo-EM Data Heterogeneity. Biomolecules 2022; 12:biom12050628. [PMID: 35625556 PMCID: PMC9138638 DOI: 10.3390/biom12050628] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 04/15/2022] [Accepted: 04/18/2022] [Indexed: 02/04/2023] Open
Abstract
Single-particle cryogenic electron microscopy (cryo-EM) has become an indispensable tool to probe high-resolution structural detail of biomolecules. It enables direct visualization of the biomolecules and opens a possibility for averaging molecular images to reconstruct a three-dimensional Coulomb potential density map. Newly developed algorithms for data analysis allow for the extraction of structural heterogeneity from a massive and low signal-to-noise-ratio (SNR) cryo-EM dataset, expanding our understanding of multiple conformational states, or further implications in dynamics, of the target biomolecule. This review provides an overview that briefly describes the workflow of single-particle cryo-EM, including imaging and data processing, and new methods developed for analyzing the data heterogeneity to understand the structural variability of biomolecules.
Collapse
|
4
|
Wälti MA, Canagarajah B, Schwieters CD, Clore GM. Visualization of Sparsely-populated Lower-order Oligomeric States of Human Mitochondrial Hsp60 by Cryo-electron Microscopy. J Mol Biol 2021; 433:167322. [PMID: 34688687 PMCID: PMC8627483 DOI: 10.1016/j.jmb.2021.167322] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 10/14/2021] [Accepted: 10/15/2021] [Indexed: 11/19/2022]
Abstract
Human mitochondrial Hsp60 (mtHsp60) is a class I chaperonin, 51% identical in sequence to the prototypical E. coli chaperonin GroEL. mtHsp60 maintains the proteome within the mitochondrion and is associated with various neurodegenerative diseases and cancers. The oligomeric assembly of mtHsp60 into heptameric ring structures that enclose a folding chamber only occurs upon addition of ATP and is significantly more labile than that of GroEL, where the only oligomeric species is a tetradecamer. The lability of the mtHsp60 heptamer provides an opportunity to detect and visualize lower-order oligomeric states that may represent intermediates along the assembly/disassembly pathway. Using cryo-electron microscopy we show that, in addition to the fully-formed heptamer and an "inverted" tetradecamer in which the two heptamers associate via their apical domains, thereby blocking protein substrate access, well-defined lower-order oligomeric species, populated at less than 6% of the total particles, are observed. Specifically, we observe open trimers, tetramers, pentamers and hexamers (comprising ∼4% of the total particles) with rigid body rotations from one subunit to the next within ∼1.5-3.5° of that for the heptamer, indicating that these may lie directly on the assembly/disassembly pathway. We also observe a closed-ring hexamer (∼2% of the particles) which may represent an off-pathway species in the assembly/disassembly process in so far that conversion to the mature heptamer would require the closed-ring hexamer to open to accept an additional subunit. Lastly, we observe several classes of tetramers where additional subunits characterized by fuzzy electron density are caught in the act of oligomer extension.
Collapse
Affiliation(s)
- Marielle A Wälti
- Laboratory of Chemical Physics, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, MD 20892-0520, USA
| | - Bertram Canagarajah
- Laboratory of Cell and Molecular Biology, and National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, MD 20892-0520, USA
| | - Charles D Schwieters
- Computational Biomolecular Nuclear Magnetic Resonance Core, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, MD 20892-0520, USA
| | - G Marius Clore
- Laboratory of Chemical Physics, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, MD 20892-0520, USA.
| |
Collapse
|
5
|
Giraldo-Barreto J, Ortiz S, Thiede EH, Palacio-Rodriguez K, Carpenter B, Barnett AH, Cossio P. A Bayesian approach to extracting free-energy profiles from cryo-electron microscopy experiments. Sci Rep 2021; 11:13657. [PMID: 34211017 PMCID: PMC8249403 DOI: 10.1038/s41598-021-92621-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Accepted: 06/01/2021] [Indexed: 11/08/2022] Open
Abstract
Cryo-electron microscopy (cryo-EM) extracts single-particle density projections of individual biomolecules. Although cryo-EM is widely used for 3D reconstruction, due to its single-particle nature it has the potential to provide information about a biomolecule's conformational variability and underlying free-energy landscape. However, treating cryo-EM as a single-molecule technique is challenging because of the low signal-to-noise ratio (SNR) in individual particles. In this work, we propose the cryo-BIFE method (cryo-EM Bayesian Inference of Free-Energy profiles), which uses a path collective variable to extract free-energy profiles and their uncertainties from cryo-EM images. We test the framework on several synthetic systems where the imaging parameters and conditions were controlled. We found that for realistic cryo-EM environments and relevant biomolecular systems, it is possible to recover the underlying free energy, with the pose accuracy and SNR as crucial determinants. We then use the method to study the conformational transitions of a calcium-activated channel with real cryo-EM particles. Interestingly, we recover not only the most probable conformation (used to generate a high-resolution reconstruction of the calcium-bound state) but also a metastable state that corresponds to the calcium-unbound conformation. As expected for turnover transitions within the same sample, the activation barriers are on the order of [Formula: see text]. We expect our tool for extracting free-energy profiles from cryo-EM images to enable more complete characterization of the thermodynamic ensemble of biomolecules.
Collapse
Affiliation(s)
- Julian Giraldo-Barreto
- Biophysics of Tropical Diseases Max Planck Tandem Group, University of Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia
- Magnetism and Simulation Group, University of Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia
| | - Sebastian Ortiz
- Biophysics of Tropical Diseases Max Planck Tandem Group, University of Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia
| | - Erik H Thiede
- Center for Computational Mathematics, Flatiron Institute, New York City, USA
| | - Karen Palacio-Rodriguez
- Institut de Minéralogie, de Physique des Matériaux et de Cosmochimie, Sorbonne Université, Paris, France
| | - Bob Carpenter
- Center for Computational Mathematics, Flatiron Institute, New York City, USA
| | - Alex H Barnett
- Center for Computational Mathematics, Flatiron Institute, New York City, USA
| | - Pilar Cossio
- Biophysics of Tropical Diseases Max Planck Tandem Group, University of Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia.
- Department of Theoretical Biophysics, Max Planck Institute of Biophysics, 60438, Frankfurt am Main, Germany.
| |
Collapse
|
6
|
Zhang Y, Krieger J, Mikulska-Ruminska K, Kaynak B, Sorzano COS, Carazo JM, Xing J, Bahar I. State-dependent sequential allostery exhibited by chaperonin TRiC/CCT revealed by network analysis of Cryo-EM maps. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2021; 160:104-120. [PMID: 32866476 PMCID: PMC7914283 DOI: 10.1016/j.pbiomolbio.2020.08.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 06/25/2020] [Accepted: 08/16/2020] [Indexed: 12/17/2022]
Abstract
The eukaryotic chaperonin TRiC/CCT plays a major role in assisting the folding of many proteins through an ATP-driven allosteric cycle. Recent structures elucidated by cryo-electron microscopy provide a broad view of the conformations visited at various stages of the chaperonin cycle, including a sequential activation of its subunits in response to nucleotide binding. But we lack a thorough mechanistic understanding of the structure-based dynamics and communication properties that underlie the TRiC/CCT machinery. In this study, we present a computational methodology based on elastic network models adapted to cryo-EM density maps to gain a deeper understanding of the structure-encoded allosteric dynamics of this hexadecameric machine. We have analysed several structures of the chaperonin resolved in different states toward mapping its conformational landscape. Our study indicates that the overall architecture intrinsically favours cooperative movements that comply with the structural variabilities observed in experiments. Furthermore, the individual subunits CCT1-CCT8 exhibit state-dependent sequential events at different states of the allosteric cycle. For example, in the ATP-bound state, subunits CCT5 and CCT4 selectively initiate the lid closure motions favoured by the overall architecture; whereas in the apo form of the heteromer, the subunit CCT7 exhibits the highest predisposition to structural change. The changes then propagate through parallel fluxes of allosteric signals to neighbours on both rings. The predicted state-dependent mechanisms of sequential activation provide new insights into TRiC/CCT intra- and inter-ring signal transduction events.
Collapse
Affiliation(s)
- Yan Zhang
- Department of Computational and Systems Biology, University of Pittsburgh, 800 Murdoch Building, 3420 Forbes Avenue, Pittsburgh, PA, 15261, USA
| | - James Krieger
- Department of Computational and Systems Biology, University of Pittsburgh, 800 Murdoch Building, 3420 Forbes Avenue, Pittsburgh, PA, 15261, USA
| | - Karolina Mikulska-Ruminska
- Department of Computational and Systems Biology, University of Pittsburgh, 800 Murdoch Building, 3420 Forbes Avenue, Pittsburgh, PA, 15261, USA
| | - Burak Kaynak
- Department of Computational and Systems Biology, University of Pittsburgh, 800 Murdoch Building, 3420 Forbes Avenue, Pittsburgh, PA, 15261, USA
| | | | - José-María Carazo
- Centro Nacional de Biotecnología (CSIC), Darwin, 3, 28049, Madrid, Spain
| | - Jianhua Xing
- Department of Computational and Systems Biology, University of Pittsburgh, 800 Murdoch Building, 3420 Forbes Avenue, Pittsburgh, PA, 15261, USA
| | - Ivet Bahar
- Department of Computational and Systems Biology, University of Pittsburgh, 800 Murdoch Building, 3420 Forbes Avenue, Pittsburgh, PA, 15261, USA.
| |
Collapse
|
7
|
Zhang J, Wang Z, Liu Z, Zhang F. Improve the Resolution and Parallel Performance of the Three-Dimensional Refine Algorithm in RELION Using CUDA and MPI. IEEE/ACM TRANSACTIONS ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS 2021; 18:583-595. [PMID: 31329127 DOI: 10.1109/tcbb.2019.2929171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
In cryo-electron microscopy, RELION is a powerful tool for high-resolution reconstruction. Due to the complicated imaging procedure and the heterogeneity of particles, some of the selected particle images offer more disturbing information than others. However, in the current RELION, all these particle images are treated equally. In our work, we extend RELION's model with one scalar parameter to score the contribution of a particle depending on the error between the experimental particle and the corresponding reprojection. This scores down weight potentially poor particles, hence accelerating the convergence. Besides, by now there is no sophisticated memory management system for RELION, fragmentation on GPU will increase with iterations, eventually crashing the program. In our work, we designed the stack-based memory management system to guarantee the stability of RELION and to optimize the memory usage condition. Also, to reduce memory usage, we developed a customized compressed data structure for the memory-demanding weight array. In addition, to speed up the GPU version of RELION, we proposed two highly efficient parallel algorithms for weight calculation algorithm and weight selection algorithm. Experiments show that compared with RELION, the optimized three-dimensional refine algorithm can speed up the converge procedure, the memory system can avoid memory fragmentation, and a better speed-up ratio can be obtained.
Collapse
|
8
|
Ortiz S, Stanisic L, Rodriguez BA, Rampp M, Hummer G, Cossio P. Validation tests for cryo-EM maps using an independent particle set. J Struct Biol X 2020; 4:100032. [PMID: 32743544 PMCID: PMC7385033 DOI: 10.1016/j.yjsbx.2020.100032] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Cryo-electron microscopy (cryo-EM) has revolutionized structural biology by providing 3D density maps of biomolecules at near-atomic resolution. However, map validation is still an open issue. Despite several efforts from the community, it is possible to overfit 3D maps to noisy data. Here, we develop a novel methodology that uses a small independent particle set (not used during the 3D refinement) to validate the maps. The main idea is to monitor how the map probability evolves over the control set during the 3D refinement. The method is complementary to the gold-standard procedure, which generates two reconstructions at each iteration. We low-pass filter the two reconstructions for different frequency cutoffs, and we calculate the probability of each filtered map given the control set. For high-quality maps, the probability should increase as a function of the frequency cutoff and the refinement iteration. We also compute the similarity between the densities of probability distributions of the two reconstructions. As higher frequencies are included, the distributions become more dissimilar. We optimized the BioEM package to perform these calculations, and tested it over systems ranging from quality data to pure noise. Our results show that with our methodology, it possible to discriminate datasets that are constructed from noise particles. We conclude that validation against a control particle set provides a powerful tool to assess the quality of cryo-EM maps.
Collapse
Affiliation(s)
- Sebastian Ortiz
- Biophysics of Tropical Diseases, Max Planck Tandem Group, University of Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia
| | - Luka Stanisic
- Max Planck Computing and Data Facility, 85748 Garching, Germany
| | - Boris A Rodriguez
- Grupo de Fósica Atómica y Molecular, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia
| | - Markus Rampp
- Max Planck Computing and Data Facility, 85748 Garching, Germany
| | - Gerhard Hummer
- Department of Theoretical Biophysics, Max Planck Institute of Biophysics, 60438 Frankfurt am Main, Germany
- Institute of Biophysics, Goethe University, 60438 Frankfurt am Main, Germany
| | - Pilar Cossio
- Biophysics of Tropical Diseases, Max Planck Tandem Group, University of Antioquia UdeA, Calle 70 No. 52-21, Medellín, Colombia
- Department of Theoretical Biophysics, Max Planck Institute of Biophysics, 60438 Frankfurt am Main, Germany
| |
Collapse
|
9
|
Abstract
Cross-validation is used to determine the validity of a model on unseen data by assessing if the model is overfitted to noise. It is widely used in many fields, from artificial intelligence to structural biology in X-ray crystallography and nuclear magnetic resonance. Although there are concerns of map overfitting in cryo-electron microscopy (cryo-EM), cross-validation is rarely used. The problem is that establishing a performance metric of the maps over unseen data (given by 2D-projection images) is difficult due to the low signal-to-noise ratios in the individual particles. Here, I present recent advances for cryo-EM map reconstruction. I highlight that the gold-standard procedure can fail to detect map overfitting in certain cases, showing the necessity of assessing the map quality on unbiased data. Finally, I describe the challenges and advantages of developing a robust cross-validation methodology for cryo-EM.
Collapse
Affiliation(s)
- Pilar Cossio
- Biophysics of Tropical Diseases, Max Planck Tandem Group, University of Antioquia UdeA, Calle 70 No. 52-21, Medellin, Colombia.,Department of Theoretical Biophysics, Max Planck Institute of Biophysics, 60438 Frankfurt am Main, Germany
| |
Collapse
|
10
|
Harastani M, Sorzano COS, Jonić S. Hybrid Electron Microscopy Normal Mode Analysis with Scipion. Protein Sci 2019; 29:223-236. [PMID: 31693263 DOI: 10.1002/pro.3772] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Revised: 11/03/2019] [Accepted: 11/04/2019] [Indexed: 12/12/2022]
Abstract
Hybrid Electron Microscopy Normal Mode Analysis (HEMNMA) method was introduced in 2014. HEMNMA computes normal modes of a reference model (an atomic structure or an electron microscopy map) of a molecular complex and uses this model and its normal modes to analyze single-particle images of the complex to obtain information on its continuous conformational changes, by determining the full distribution of conformational variability from the images. An advantage of HEMNMA is a simultaneous determination of all parameters of each image (particle conformation, orientation, and shift) through their iterative optimization, which allows applications of HEMNMA even when the effects of conformational changes dominate those of orientational changes. HEMNMA was first implemented in Xmipp and was using MATLAB for statistical analysis of obtained conformational distributions and for fitting of underlying trajectories of conformational changes. A HEMNMA implementation independent of MATLAB is now available as part of a plugin of Scipion V2.0 (http://scipion.i2pc.es). This plugin, named ContinuousFlex, can be installed by following the instructions at https://pypi.org/project/scipion-em-continuousflex. In this article, we present this new HEMNMA software, which is user-friendly, totally free, and open-source. STATEMENT FOR A BROADER AUDIENCE: This article presents Hybrid Electron Microscopy Normal Mode Analysis (HEMNMA) software that allows analyzing single-particle images of a complex to obtain information on continuous conformational changes of the complex, by determining the full distribution of conformational variability from the images. The HEMNMA software is user-friendly, totally free, open-source, and available as part of ContinuousFlex plugin (https://pypi.org/project/scipion-em-continuousflex) of Scipion V2.0 (http://scipion.i2pc.es).
Collapse
Affiliation(s)
- Mohamad Harastani
- Sorbonne Université, UMR CNRS 7590, Muséum National d'Histoire Naturelle, IRD, Institut de Minéralogie, de Physique des Matériaux et de Cosmochimie, IMPMC, Paris, France
| | | | - Slavica Jonić
- Sorbonne Université, UMR CNRS 7590, Muséum National d'Histoire Naturelle, IRD, Institut de Minéralogie, de Physique des Matériaux et de Cosmochimie, IMPMC, Paris, France
| |
Collapse
|
11
|
Bonomi M, Vendruscolo M. Determination of protein structural ensembles using cryo-electron microscopy. Curr Opin Struct Biol 2019; 56:37-45. [DOI: 10.1016/j.sbi.2018.10.006] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Revised: 10/24/2018] [Accepted: 10/26/2018] [Indexed: 10/27/2022]
|
12
|
Köfinger J, Różycki B, Hummer G. Inferring Structural Ensembles of Flexible and Dynamic Macromolecules Using Bayesian, Maximum Entropy, and Minimal-Ensemble Refinement Methods. Methods Mol Biol 2019; 2022:341-352. [PMID: 31396910 DOI: 10.1007/978-1-4939-9608-7_14] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The flexible and dynamic nature of biomolecules and biomolecular complexes is essential for many cellular functions in living organisms but poses a challenge for experimental methods to determine high-resolution structural models. To meet this challenge, experiments are combined with molecular simulations. The latter propose models for structural ensembles, and the experimental data can be used to steer these simulations and to select ensembles that most likely underlie the experimental data. Here, we explain in detail how the "Bayesian Inference Of ENsembles" (BioEn) method can be used to refine such ensembles using a wide range of experimental data. The "Ensemble Refinement of SAXS" (EROS) method is a special case of BioEn, inspired by the Gull-Daniell formulation of maximum entropy image processing and focused originally on X-ray solution scattering experiments (SAXS) and then extended to integrative structural modeling. We also briefly sketch the "minimum ensemble method," a maximum-parsimony refinement method that seeks to represent an ensemble with a minimal number of representative structures.
Collapse
Affiliation(s)
- Jürgen Köfinger
- Max Planck Institute of Biophysics, Frankfurt am Main, Germany.
| | - Bartosz Różycki
- Institute of Physics, Polish Academy of Sciences, Warsaw, Poland
| | - Gerhard Hummer
- Max Planck Institute of Biophysics, Frankfurt am Main, Germany.
- Department of Physics, Goethe University Frankfurt, Frankfurt am Main, Germany.
| |
Collapse
|