1
|
Lee YH, Wang CH, Hsu PH, Hsieh HC, Wang JL. A wide range of toxic VOCs measured by dual-sorbent passive sampling with validation by field online measurements. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2022; 314:120201. [PMID: 36210585 DOI: 10.1016/j.envpol.2022.120201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 09/13/2022] [Accepted: 09/14/2022] [Indexed: 06/16/2023]
Abstract
This study modified a passive sampling technique similar to the US EPA Method 325 A/B method but extended to include more toxic volatile organic compounds (VOCs) under varied climate conditions to enhance field applicability. A mixing chamber was built to determine uptake rates (Us) for the target compounds. It was found that the Us of 27 air toxics previously reported in the literature agreed reasonably well with our findings within 18%, thus proving the chamber's integrity. To broaden the compound coverage, both Carbopack X and Carboxen 569 were studied for a suite of toxic VOCs to meet stringent quality control (QC) criteria of correlation coefficients (R-square), method detection limits (MDL), back diffusion (BD), storage stability, as well as a wide range of climate conditions in temperature and humidity. After excluding the species that failed to pass any of the QC criteria, Carbopack X was found to fit 50 air toxics, whereas Carboxen 569 held 37. After excluding the overlapped species, 61 toxic VOCs can be determined with robust Us for a broad range of climate conditions when the two sorbents are used in pairs. A one-week field measurement was conducted to compare with the online thermal desorption gas chromatography-mass spectrometry (TD-GC-MS) with hourly data resolution. The field passive sampling showed comparable results to the means of the online hourly measurements, despite the high variability of selected target compounds, such as toluene from 0.3 ppbv as the 5th percentile to the maximum of about 80 ppbv. Passive sampling clearly demonstrated the ability to smooth out concentration variability and thus the time-averaging strength of toxic VOCs, revealing its ideal role as an exposure monitor over time. The passive sampling method can be more desired than active sampling or online methods when the aim is simply the knowledge of prolonged time-averaged concentrations.
Collapse
Affiliation(s)
- Yu-Hsun Lee
- Department of Chemistry, National Central University, Taoyuan, 320, Taiwan
| | - Chieh-Heng Wang
- Center for Environmental Studies, National Central University, Taoyuan, 320, Taiwan
| | - Pei-Hsuan Hsu
- Department of Chemistry, National Central University, Taoyuan, 320, Taiwan
| | - Hsin-Cheng Hsieh
- Department of Chemistry, National Central University, Taoyuan, 320, Taiwan
| | - Jia-Lin Wang
- Department of Chemistry, National Central University, Taoyuan, 320, Taiwan.
| |
Collapse
|
2
|
Helmig D, Fangmeyer J, Fuchs J, Hueber J, Smith K. Evaluation of selected solid adsorbents for passive sampling of atmospheric oil and natural gas non-methane hydrocarbons. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 2022; 72:235-255. [PMID: 34738882 DOI: 10.1080/10962247.2021.2000518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Revised: 10/12/2021] [Accepted: 10/18/2021] [Indexed: 06/13/2023]
Abstract
This project investigated passive adsorbent sampling of light (C2-C5) hydrocarbons which are sensitive tracers of fugitive emissions from oil and natural gas (O&NG) sources. Stronger adsorbent materials, i.e. Carboxen 1000 and Carboxen 1016, than those typically used in adsorbent sampling were considered. Experiments were conducted in laboratory and field settings using thermal desorption - gas chromatography analysis. Uptake of water vapor and system blanks were challenges inherent to the increased affinity of these adsorbents. Carboxen 1000 exhibited the best signal-to-noise ratio for the target compounds after optimizing conditioning parameters to reduce blanks, and by reducing the adsorbent mass loaded in the cartridge. This strategy reduced blanks to equivalent ambient air mole fractions of <0.05 nmol mol-1 (ppb), and allowed determination of these O&NG tracers over three-day sampling intervals with a lower detection limit of ≥0.5-1 ppb. Linear VOCs uptake was observed in dry air. Water uptake was as high as 0.65 gH2O g-1adsorbent at relative humidity (RH) above ≈ 75%. The water collection passivates adsorbent sites and competes with the uptake rates of VOCs; under the worst case relative humidity level of 95% RH, VOCs uptake rates dropped to 27-39% of those in dry air. This effect potentially causes results to be biased low when cartridges are deployed at high relative humidity (RH), including overnight, when RH is often elevated over daytime levels. Nonetheless, representative sampling results were obtained under ambient conditions during three field studies where cartridges were evaluated alongside whole air sample collection in canisters. Agreement varied by compound: Ethane and alkenes correlated poorly and could not be analyzed with satisfactory results; results for C3-C5 alkanes were much better: i-butane correlated with R2 > 0.5, and propane, n-butane, i-pentane, and n-pentane with R2 > 0.75, which demonstrates the feasibility of the passive sampling of these latter O&NG tracers. Implications: Oil and natural gas development has been associated with emissions of petroleum hydrocarbons that impact air quality and human health. This research characterizes and defines the application possibilities of solid adsorbent sampling for atmospheric passive sampling monitoring of low molecular weight volatile organic compounds (i.e. ethane through pentane isomers) that are most commonly emitted from natural gas drilling and well sites. The passive sampling of these pollutants offers a simple, low cost, and readily applicable monitoring method for assessing emissions and air quality impacts in the surroundings of oil and gas operations.
Collapse
Affiliation(s)
- Detlev Helmig
- Institute of Arctic and Alpine Research, University of Colorado, Boulder, Colorado, USA
- Boulder A.I.R. LLC, Boulder, Colorado, USA
| | - Jens Fangmeyer
- Institute of Arctic and Alpine Research, University of Colorado, Boulder, Colorado, USA
- Institute of Inorganic and Analytical Chemistry, University of Muenster, Muenster, Germany
| | - Joshua Fuchs
- Institute of Arctic and Alpine Research, University of Colorado, Boulder, Colorado, USA
- Institute of Inorganic and Analytical Chemistry, University of Muenster, Muenster, Germany
| | - Jacques Hueber
- Institute of Arctic and Alpine Research, University of Colorado, Boulder, Colorado, USA
| | - Kate Smith
- Institute of Arctic and Alpine Research, University of Colorado, Boulder, Colorado, USA
- Department of Chemistry, University of York, York, UK
| |
Collapse
|
3
|
Pytel K, Marcinkowska R, Zabiegała B. Investigation on air quality of specific indoor environments-spa salons located in Gdynia, Poland. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:59214-59232. [PMID: 32661962 PMCID: PMC8541956 DOI: 10.1007/s11356-020-09860-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Accepted: 06/22/2020] [Indexed: 05/11/2023]
Abstract
Due to excessive application of essential oils and scented products in spa salons during aromatherapy and massage sessions, the elevated concentration of total volatile organic compounds (TVOCs), particularly terpenes, which are known as secondary organic aerosol (SOA) precursors, is expected there. This study was aimed at determination of VOCs with a particular regard to terpenes in air samples collected in selected spa salons located in Northern Poland. Active air sampling was conducted before and after treatments. Samples were analyzed with the use of thermal desorption gas chromatography coupled with flame-ionization detector (TD-GC-FID) and mass spectrometer (TD-GC-MS). Obtained results allowed to characterize chemical composition of indoor air of spa salons and also to relate the dependence between applied essential oil and indoor air chemical composition. It has been proved that (i) spa salons are characterized by TVOC concentrations exceeding recommended values of 300-400 μg m-3 in most of examined cases, reaching up to several thousand of micrograms per cubic meter, (ii) TVOC concentration is strictly related to salon characteristics and carried out treatments, (iii) terpenes constitute a significant part of TVOCs present in spa indoor air, from 22 up to 86%, (iv) most commonly investigated terpenes in the literature (D-limonene, α-pinene, camphene, and linalool) were also determined at the highest concentration levels in this study and (v) VOC chemical composition is strictly dependent on the type of applied essential oils. On the basis of obtained results, it may be stated that extensive application of essential oils rich in terpenes can significantly alter indoor air chemistry of spa salons, thereby influencing health and well-being of employees working there. Graphical abstract.
Collapse
Affiliation(s)
- Klaudia Pytel
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, G. Narutowicza 11/12 Str., 80-233, Gdańsk, Poland
| | - Renata Marcinkowska
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, G. Narutowicza 11/12 Str., 80-233, Gdańsk, Poland.
| | - Bożena Zabiegała
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, G. Narutowicza 11/12 Str., 80-233, Gdańsk, Poland
| |
Collapse
|
4
|
Apblett A, Materer N, Kadossov E, Shaikh S. Superior Monitoring of Chemical Exposure Using Nanoconfinement Technology. Mil Med 2021; 186:795-800. [PMID: 33499467 DOI: 10.1093/milmed/usaa372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 09/04/2020] [Accepted: 09/21/2020] [Indexed: 11/12/2022] Open
Abstract
INTRODUCTION Military personnel are exposed to a broad range of potentially toxic compounds that can affect their health. These hazards are unpredictable because military service occurs in a wide array of uncontrolled environments. Therefore, a novel sorbent was developed that allows the fabrication of lightweight personal samplers that are both capable of sorbing an extremely wide range of organic chemical types and able to stabilize reactive compounds. MATERIALS AND METHODS OSU-6, a nanoporous silica, was provided by XploSafe LLC. The sorption capacity for several volatile organic compounds, the temperatures required for thermal desorption of adsorbed compounds, and the sampling rates for targeted analytes were determined. RESULTS The uptake capacity was found to be on average 1.5 g/g of sorbent. Analytes were not only held tightly but also could be desorbed upon heating the sorbate to temperatures below 150°C. Sampling rates for volatile organic compound by an OSU-6 sampler badge were on average, 5.7 times higher than those for a commercially available activated carbon badge. Theoretical calculations showed that sorption of volatile organic compounds on the surface of the tightly curved pore walls in OSU-6 is because of exceptionally strong cumulative addition of Van der Waals forces. Analytes could readily be analyzed by either solvent extraction or thermal desorption gas chromatography/mass spectrometry techniques. Excellent sampling rates, high concentrations of analytes in the OSU-6 sorbent matrix, and high desorption efficiencies (recoveries) were obtained using the thermal desorption method. CONCLUSIONS The performance of the OSU-6 sorbent makes it highly capable of meeting the need for personal samplers that enable Individual Longitudinal Exposure Records development. It can adsorb an extremely wide array of different volatile organic compounds, it can stabilize reactive compounds, it has high sampling rates coupled with high capacity that provide both sensitivity and resistance to saturation, and it is unique in being very amenable to thermal desorption in combination with having strong sorbate binding and high capacity and surface area.
Collapse
Affiliation(s)
- Allen Apblett
- Department of Chemistry, Oklahoma State University, Stillwater, OK 74078, USA
| | - Nicholas Materer
- Department of Chemistry, Oklahoma State University, Stillwater, OK 74078, USA
| | | | | |
Collapse
|
5
|
Li Q, Wang X, Wang X, Lan Y, Hu J. Tube-type passive sampling of cyclic volatile methyl siloxanes (cVMSs) and benzene series simultaneously in indoor air: uptake rate determination and field application. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2020; 22:973-980. [PMID: 32044895 DOI: 10.1039/c9em00445a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Cyclic volatile methyl siloxanes (cVMSs) and benzene series compounds have attracted increasing attention because they are associated with various adverse health effects. In this study, we developed and validated a novel passive air sampling method (PAS), using Tenax-TA as the sorbent, to measure the concentrations of cVMSs (D4, D5, and D6) and benzene series compounds simultaneously in indoor air. The uptake rates (R), which were calibrated side-by-side by an active air sampling method (Tenax-TA-AAS), ranged from 0.10 to 0.56 mL min-1 depending on chemicals, and the R of the TD tube with Tenax-TA was controlled by the sampler material-side and not the air-side. The passive sampling efficiency (PSE) of styrene and m,p-xylene was close to 1. Based on Pearson correlation analysis, a negative correlation was found between the molecular weight of compounds and their uptake rates. Furthermore, the calibrated Tenax-TA-PAS method was used to quantify cVMSs and benzene series compounds in a living room and an office environment in the urban area of Dalian, China. The concentrations of toluene were the highest in both the living room (10.4 μg m-3) and office (7.02 μg m-3) among the target compounds.
Collapse
Affiliation(s)
- Qingbo Li
- College of Environmental Science and Engineering, Dalian Maritime University, Dalian 116026, China.
| | | | | | | | | |
Collapse
|
6
|
Murga A, Kuga K, Yoo SJ, Ito K. Can the inhalation exposure of a specific worker in a cross-ventilated factory be evaluated by time- and spatial-averaged contaminant concentration? ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2019; 252:1388-1398. [PMID: 31254896 DOI: 10.1016/j.envpol.2019.06.056] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Revised: 05/30/2019] [Accepted: 06/13/2019] [Indexed: 06/09/2023]
Abstract
Industry implies economic growth; however, outdoor and indoor air pollution generated by industrial activities represents a widespread problem for the environment and human beings. In terms of human health, indoor air quality assessment has become essential in a society where people spend most of their time in indoor dwellings, as in the case of industry workers. Because indoor air quality is strongly affected by the outdoor environment, especially under natural ventilation conditions (e.g., cross-ventilation), a comprehensive analysis that includes outdoor atmospheric-urban environment is needed to reproduce realistic scenarios. In this context, computational fluid dynamics (CFD) is a useful tool. To perform a precise analysis of the inhalation exposure of factory workers to potential gas-phase contaminants in the working environment (i.e., inhaled dose of contaminants and potential effects), the human body and respiratory tract need to be integrated in the analysis. Therefore, in this study, we performed an integrated occupational inhalation exposure/toxicology assessment in a factory building that applies a computer simulated person (CSP), a virtual human respiratory tract and integrated physiologically-based toxicokinetic (PBTK) model to predict tissue dosimetry distribution. Outdoor airflow variation was transported into the enclosure through an hourly change in wind pressure coefficient to calculate transient ventilation rate and indoor contaminant concentration between 08:00 and 17:00 h. Thereafter, the time-averaged contaminant concentration calculated at the nares of the human body was employed in a steady state calculation of airflow and contaminant distribution inside the virtual respiratory tract. Subsequently, we predicted adsorbed contaminant in the first layer of tissue of the human airways; highest adsorption took place in the nasal cavity. Finally, based on the results of the comprehensive coupled numerical analysis performed using the CFD-CSP-PBTK model, we quantitatively discussed differences between the inhalation exposure concentration and representative contaminant concentration in the factory space (e.g., time and volume-averaged concentration).
Collapse
Affiliation(s)
- Alicia Murga
- Faculty of Engineering Sciences, Kyushu University, Japan.
| | - Kazuki Kuga
- Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Japan
| | - Sung-Jun Yoo
- Faculty of Engineering Sciences, Kyushu University, Japan
| | - Kazuhide Ito
- Faculty of Engineering Sciences, Kyushu University, Japan
| |
Collapse
|