Liu L, Ma Y, Huang R, Jia M, Liu G, Zheng W. Field measurement study of indoor thermal environment of badminton halls in a hot summer and cold winter region in different seasons in China. Heliyon 2024; 10:e34883. [PMID: 39144935 PMCID: PMC11320213 DOI: 10.1016/j.heliyon.2024.e34883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Revised: 07/17/2024] [Accepted: 07/18/2024] [Indexed: 08/16/2024] Open
Abstract
The indoor thermal environment has a direct impact on human thermal comfort and health. In order to assess the status of the indoor thermal environment of typical sports buildings in hot summer and cold winter climate zones in China, 14 badminton halls in 10 cities in Hubei Province (including 5 venues in Wuhan) in this climate zone are chosen as research objects for field testing of indoor thermal environment parameters in 4 seasons. All the tested stadiums are naturally ventilated in non-event conditions. The results reveal that the average indoor temperature of badminton halls in summer is excessively high (i.e., 31.89 °C), which is higher than the regulation specified in JGJ31-2003 or GB-T18883-2022 on the reference interval of the indoor air temperature of venues in summer, (i.e., (26-28 °C) or (22-28 °C), respectively). The average indoor temperature of badminton halls in winter is too low (i.e., 12.95 °C), and it is lower than the recommendations of JGJ31-2003 or GB-T18883-2022 on the reference interval of the indoor air temperature of venues in winter (i.e., (16-18 °C) or (16-24 °C), respectively), relative humidity and air velocity are in the thermal comfort interval for all seasons, and the indoor thermal environment factors of badminton courts in spring and autumn meet the comfort requirements. The indoor and outdoor temperatures and the relative humidity of badminton courts are highly correlated. The indoor temperature and relative humidity vary according to changes in those factors outdoors, whereas the air velocity is not affected by outdoor changes. In the hot summer and cold winter climate zones, some discrepancies in the indoor temperature variation patterns of badminton halls at various altitudes are detectable. The results of this study aim to provide a solid basis for the development of indoor thermal-comfort standards for sports stadiums in China.
Collapse
Affiliation(s)
- Lin Liu
- Engineering Research Center of Sports Health Intelligent Equipment of Hubei Province, Wuhan Sports University, Wuhan, 430079, China
- Research Center of Sports Equipment Engineering Technology of Hubei Province, Wuhan Sports University, Wuhan, 430079, China
- Key Laboratory of Sports Engineering of General Administration of Sport of China, Wuhan Sports University, Wuhan, 430079, China
| | - Yong Ma
- Engineering Research Center of Sports Health Intelligent Equipment of Hubei Province, Wuhan Sports University, Wuhan, 430079, China
- Research Center of Sports Equipment Engineering Technology of Hubei Province, Wuhan Sports University, Wuhan, 430079, China
- Key Laboratory of Sports Engineering of General Administration of Sport of China, Wuhan Sports University, Wuhan, 430079, China
| | - Ruifeng Huang
- Engineering Research Center of Sports Health Intelligent Equipment of Hubei Province, Wuhan Sports University, Wuhan, 430079, China
- Research Center of Sports Equipment Engineering Technology of Hubei Province, Wuhan Sports University, Wuhan, 430079, China
- Key Laboratory of Sports Engineering of General Administration of Sport of China, Wuhan Sports University, Wuhan, 430079, China
| | - Mengyao Jia
- Engineering Research Center of Sports Health Intelligent Equipment of Hubei Province, Wuhan Sports University, Wuhan, 430079, China
- Research Center of Sports Equipment Engineering Technology of Hubei Province, Wuhan Sports University, Wuhan, 430079, China
- Key Laboratory of Sports Engineering of General Administration of Sport of China, Wuhan Sports University, Wuhan, 430079, China
| | - Gan Liu
- Engineering Research Center of Sports Health Intelligent Equipment of Hubei Province, Wuhan Sports University, Wuhan, 430079, China
- Research Center of Sports Equipment Engineering Technology of Hubei Province, Wuhan Sports University, Wuhan, 430079, China
- Key Laboratory of Sports Engineering of General Administration of Sport of China, Wuhan Sports University, Wuhan, 430079, China
| | - Weitao Zheng
- Engineering Research Center of Sports Health Intelligent Equipment of Hubei Province, Wuhan Sports University, Wuhan, 430079, China
- Research Center of Sports Equipment Engineering Technology of Hubei Province, Wuhan Sports University, Wuhan, 430079, China
- Key Laboratory of Sports Engineering of General Administration of Sport of China, Wuhan Sports University, Wuhan, 430079, China
| |
Collapse
|
2
|
Peixoto C, Pereira MDC, Morais S, Slezakova K. Assessment of indoor air quality in health clubs: insights into (ultra)fine and coarse particles and gaseous pollutants. Front Public Health 2023; 11:1310215. [PMID: 38089025 PMCID: PMC10715262 DOI: 10.3389/fpubh.2023.1310215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 11/10/2023] [Indexed: 12/18/2023] Open
Abstract
Introduction Exercising on regular basis provides countless health benefits. To ensure the health, well-being and performance of athletes, optimal indoor air quality, regular maintenance and ventilation in sport facilities are essential. Methods This study assessed the levels of particulate, down to the ultrafine range (PM10, PM2.5, and particle number concentration in size range of 20-1,000 nm, i.e., - PNC20-1000 nm), gaseous pollutants (total volatile organic compounds - TVOCs, CO2, and O3) and comfort parameters (temperature - T, relative humidity - RH) in different functional spaces of health clubs (n = 8), under specific occupancy and ventilation restrictions. Results and Discussion In all HCs human occupancy resulted in elevated particles (up to 2-3 times than those previously reported), considering mass concentrations (PM10: 1.9-988.5 μg/m3 PM2.5: 1.6-479.3 μg/m3) and number (PNC 1.23 × 103 - 9.14 × 104 #/cm3). Coarse and fine PM indicated a common origin (rs = 0.888-0.909), while PNC showed low-moderate associations with particle mass (rs = 0.264-0.629). In addition, up to twice-higher PM and PNC were detected in cardiofitness & bodybuilding (C&B) areas as these spaces were the most frequented, reinforcing the impacts of occupational activities. In all HCs, TVOCs (0.01-39.67 mg/m3) highly exceeded the existent protection thresholds (1.6-8.9 times) due to the frequent use of cleaning products and disinfectants (2-28 times higher than in previous works). On contrary to PM and PNC, TVOCs were higher (1.1-4.2 times) in studios than in C&B areas, due to the limited ventilations combined with the smaller room areas/volumes. The occupancy restrictions also led to reduced CO2 (122-6,914 mg/m3) than previously observed, with the lowest values in HCs with natural airing. Finally, the specific recommendations for RH and T in sport facilities were largely unmet thus emphasizing the need of proper ventilation procedures in these spaces.
Collapse
Affiliation(s)
- Cátia Peixoto
- REQUIMTE–LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida, Porto, Portugal
- LEPABE-ALiCE, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, Porto, Portugal
| | - Maria do Carmo Pereira
- LEPABE-ALiCE, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, Porto, Portugal
| | - Simone Morais
- REQUIMTE–LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida, Porto, Portugal
| | - Klara Slezakova
- LEPABE-ALiCE, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, Porto, Portugal
| |
Collapse
|
3
|
Zhang D, Ortiz MA, Bluyssen PM. A review on indoor environmental quality in sports facilities: Indoor air quality and ventilation during a pandemic. INDOOR + BUILT ENVIRONMENT : THE JOURNAL OF THE INTERNATIONAL SOCIETY OF THE BUILT ENVIRONMENT 2023; 32:831-851. [PMID: 38603231 PMCID: PMC9790860 DOI: 10.1177/1420326x221145862] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2023]
Abstract
Because of COVID-19, the indoor environmental quality (IEQ) in sports facilities has been a concern to environmental health practitioners. To develop an overall understanding of the available guidelines and standards and studies performed on IEQ in sports facilities, an extensive literature study was conducted, with the aim of identifying: (1) indicators that are being used to assess IEQ in different sports facilities; (2) indicators that are potentially interesting to be used to assess indoor air, in particular; (3) gaps in knowledge to determine whether sports facilities are safe, healthy and comfortable for people to stay and perform their activities. The outcome indicates that most current standards and previous investigations on IEQ in sports facilities mainly focused on dose-related indicators (such as ventilation rate), while building-related indicators (such as ventilation regime) and occupant-related indicators (such as IEQ preferences) were rarely considered. Little attention is given to the fact that ventilation systems may play an important role in the air quality of the location, and few investigations have been performed on the transmission of SARS-CoV-2. This study recommends more research into both occupant and building-related indicators as well as cross-modal effects between various IEQ factors for developing future standards on sports facilities.
Collapse
Affiliation(s)
- Dadi Zhang
- Chair Indoor Environment, Faculty of Architecture and the Built Environment, Delft University of Technology, Delf, The Netherlands
| | - Marco A Ortiz
- Chair Indoor Environment, Faculty of Architecture and the Built Environment, Delft University of Technology, Delf, The Netherlands
| | - Philomena M Bluyssen
- Chair Indoor Environment, Faculty of Architecture and the Built Environment, Delft University of Technology, Delf, The Netherlands
| |
Collapse
|
4
|
Weng J, Zhang Y, Chen Z, Ying X, Zhu W, Sun Y. Field Measurements and Analysis of Indoor Environment, Occupant Satisfaction, and Sick Building Syndrome in University Buildings in Hot Summer and Cold Winter Regions in China. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 20:554. [PMID: 36612874 PMCID: PMC9819874 DOI: 10.3390/ijerph20010554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 12/12/2022] [Accepted: 12/20/2022] [Indexed: 06/17/2023]
Abstract
Teachers and students work and study in classrooms for long durations. The indoor environment directly affects the health and satisfaction of teachers and students. To explore the performance differences between green buildings, conventional buildings, and retrofitted buildings in terms of their indoor environment, occupant satisfaction, and sick building syndrome (SBS), as well as the correlation between these different aspects, three university teaching buildings were selected in hot summer and cold winter regions in China. These included a green building (GB), a retrofitted building (RB), and a conventional building (CB). Long-term indoor environment monitoring and point-to-point measurements were conducted during the transition season and winter and the indoor environment, satisfaction, and SBS in the three buildings were compared. A sample of 399 point-to-point questionnaires was collected. A subjective-objective indoor environmental quality (IEQ) evaluation model for schools in China was established, covering satisfaction and the indoor environment. The results showed that the compliance rate of the indoor environment in the GB and RB was generally superior to that of the CB. The overall satisfaction was the highest for the GB, followed by the CB, and then the RB. The GB had the highest overall indoor environment quality score, followed by the RB and then the CB. The occurrence of SBS was lowest in the CB, followed by the GB, and then the RB. It was determined that the design of natural ventilation should be improved and that building users should be given the right to autonomous window control and temperature control. To reduce the occurrence of SBS symptoms, attention should be paid to the control of temperature and CO2 concentration. To improve learning efficiency, it suggests reducing indoor CO2 concentrations and improving desktop illuminance. This study provides a reference for improving the indoor environment and health performance of existing university teaching buildings.
Collapse
Affiliation(s)
- Jiantao Weng
- School of Spatial Planning and Design, Zhejiang University City College, Hangzhou 310015, China
- Zhejiang Engineering Research Center of Building’s Digital Carbon Neutral Technology, Hangzhou 310015, China
- School of Economics and Management, China University of Mining and Technology, Xuzhou 221116, China
- Huahui Engineering Design Group Co., Ltd, Shaoxing 312000, China
| | - Yuhan Zhang
- School of Spatial Planning and Design, Zhejiang University City College, Hangzhou 310015, China
- Zhejiang Engineering Research Center of Building’s Digital Carbon Neutral Technology, Hangzhou 310015, China
| | - Zefeng Chen
- School of Spatial Planning and Design, Zhejiang University City College, Hangzhou 310015, China
- Zhejiang Engineering Research Center of Building’s Digital Carbon Neutral Technology, Hangzhou 310015, China
| | - Xiaoyu Ying
- School of Spatial Planning and Design, Zhejiang University City College, Hangzhou 310015, China
- Zhejiang Engineering Research Center of Building’s Digital Carbon Neutral Technology, Hangzhou 310015, China
| | - Wei Zhu
- School of Spatial Planning and Design, Zhejiang University City College, Hangzhou 310015, China
- Zhejiang Engineering Research Center of Building’s Digital Carbon Neutral Technology, Hangzhou 310015, China
| | - Yukai Sun
- Hangzhou Integrative Medicine Hospital, Hangzhou 310064, China
| |
Collapse
|
5
|
Zhang F, Shi L, Liu S, Shi J, Cheng M. Indoor Air Quality in Tujia Dwellings in Hunan, China: Field Tests, Numerical Simulations, and Mitigation Strategies. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:8396. [PMID: 35886247 PMCID: PMC9325221 DOI: 10.3390/ijerph19148396] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 06/30/2022] [Accepted: 07/07/2022] [Indexed: 12/21/2022]
Abstract
Air pollution is a major health hazard. The traditional habits and unique ethnic fire culture in Hunan Tujia region result in the long-term exposure of residents, especially elderly people, to pollutants. In this study, we conducted field monitoring and assessment of indoor pollutants in the residential houses of Hunan Tujia families and subsequently visualised and simulated fire pollutants in representative residential houses by using fire-dynamic-simulator software. Pollutant-control strategies, using passive smoke collectors and resizing windows, were proposed and simulated for validation. The results revealed that passive smoke collectors reduced the pollutant concentration in the hall house by 43.96%. Furthermore, the optimal window size was 1500 mm × 1500 mm, and the most reasonable windowsill height of the firepit was 1800 mm. The results of the study can be used to improve the indoor air quality of Tujia dwellings and mitigate the adverse health effects of exposure to indoor air pollution without restricting ethnic beliefs and traditional customs.
Collapse
Affiliation(s)
- Fupeng Zhang
- School of Architecture and Art, Central South University, Changsha 410075, China; (F.Z.); (L.S.); (M.C.)
- Health Building Research Center, Central South University, Changsha 410075, China
| | - Lei Shi
- School of Architecture and Art, Central South University, Changsha 410075, China; (F.Z.); (L.S.); (M.C.)
- Health Building Research Center, Central South University, Changsha 410075, China
| | - Simian Liu
- School of Architecture and Art, Central South University, Changsha 410075, China; (F.Z.); (L.S.); (M.C.)
- Health Building Research Center, Central South University, Changsha 410075, China
| | - Jiaqi Shi
- School of Architecture and Art, Central South University, Changsha 410075, China; (F.Z.); (L.S.); (M.C.)
- Health Building Research Center, Central South University, Changsha 410075, China
- College of Architecture, Changsha University of Science & Technology, Changsha 410114, China
| | - Mengfei Cheng
- School of Architecture and Art, Central South University, Changsha 410075, China; (F.Z.); (L.S.); (M.C.)
- Health Building Research Center, Central South University, Changsha 410075, China
| |
Collapse
|