1
|
Ingwani T, Chaukura N, Mamba BB, Nkambule TTI, Gilmore AM. An optimised and validated surrogate analyte A-TEEM-PARAFAC-PLS technique for detecting and quantifying the biological oxygen demand in surface water. ANAL SCI 2024; 40:1683-1694. [PMID: 38822950 DOI: 10.1007/s44211-024-00605-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Accepted: 05/18/2024] [Indexed: 06/03/2024]
Abstract
A 5-day test duration makes BOD5 measurement unsatisfactory and hinders the development of a quick technique. Protein-like fluorescence peaks show a strong correlation between the BOD characteristics and the fluorescence intensities. For identifying and measuring BOD in surface water, a simultaneous absorbance-transmittance and fluorescence excitation-emission matrices (A-TEEM) method combined with PARAFAC (parallel factor) and PLS (partial least squares) analyses was developed using a tyrosine and tryptophan (tyr-trpt) mix as a surrogate analyte for BOD. The use of a surrogate analyte was decided upon due to lack of fluorescent BOD standards. Tyr-trpt mix standard solutions were added to surface water samples to prepare calibration and validation samples. PARAFAC analysis of excitation-emission matrices detected the tyr-trpt mix in surface water. PLS modelling demonstrated significant linearity (R2 = 0.991) between the predicted and measured tyr-trypt mix concentrations, and accuracy and robustness were all acceptable per the ICH Q2 (R2) and ASTM multivariate calibration/validation procedures guidelines. Based on a suitable and workable surrogate analyte method, these results imply that BOD can be detected and quantified using the A-TEEM-PARAFAC-PLS method. Very positive comparability between tyr-trypt mix concentrations was found, suggesting that tyr-trypt mix might eventually take the place of a BOD-based sampling protocol. Overall, this approach offers a novel tool that can be quickly applied in water treatment plant settings and is a step in supporting the trend toward rapid BOD determination in waters. Further studies should demonstrate the wide application of the method using real wastewater samples from various water treatment facilities.
Collapse
Affiliation(s)
- Thomas Ingwani
- Institute for Nanotechnology and Water Sustainability, College of Engineering, Science and Technology, University of South Africa, Johannesburg, South Africa
| | - Nhamo Chaukura
- Department of Physical and Earth Sciences, Sol Plaatje University, Kimberley, South Africa.
| | - Bhekie B Mamba
- Institute for Nanotechnology and Water Sustainability, College of Engineering, Science and Technology, University of South Africa, Johannesburg, South Africa
| | - Thabo T I Nkambule
- Institute for Nanotechnology and Water Sustainability, College of Engineering, Science and Technology, University of South Africa, Johannesburg, South Africa
| | - Adam M Gilmore
- Institute for Nanotechnology and Water Sustainability, College of Engineering, Science and Technology, University of South Africa, Johannesburg, South Africa
- Horiba Instruments Incorporated, Piscataway, NJ, USA
| |
Collapse
|
2
|
Li X, Song S, Yao J, Liao X, Chen M, Zhai J, Lang L, Lin C, Zhang N, Yuan C, Li C, Li H, Wu X, Lin J, Li C, Wang Y, Lyu J, Li M, Zhou Z, Yang M, Jia H, Yan J. Autofluorescence spectral analysis for detecting urinary stone composition in emulated intraoperative ambient. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 300:122913. [PMID: 37262970 DOI: 10.1016/j.saa.2023.122913] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Accepted: 05/23/2023] [Indexed: 06/03/2023]
Abstract
The prevalence and disease burden of urolithiasis has increased substantially worldwide in the last decade, and intraluminal holmium laser lithotripsy has become the primary treatment method. However, inappropriate laser energy settings increase the risk of perioperative complications, largely due to the lack of intraoperative information on the stone composition, which determines the stone melting point. To address this issue, we developed a fiber-based fluorescence spectrometry method that detects and classifies the autofluorescence spectral fingerprints of urinary stones into three categories: calcium oxalate, uric acid, and struvite. By applying the support vector machine (SVM), the prediction accuracy achieved 90.28 % and 96.70% for classifying calcium stones versus non-calcium stones and uric acid versus struvite, respectively. High accuracy and specificity were achieved for a wide range of working distances and angles between the fiber tip and stone surface in an emulated intraoperative ambient. Our work establishes the methodological basis for engineering a clinical device that achieves real-time, in situ classification of urinary stones for optimizing the laser ablation parameters and reducing perioperative complications in lithotripsy.
Collapse
Affiliation(s)
- Xing Li
- Advanced Institute for Brain and Intelligence, School of Physical Science and Technology, Guangxi University, Nanning 530004, China; Department of Urology, Southwest Hospital, Third Military Medical University, Chongqing 400038, China
| | - Siji Song
- Department of Urology, Southwest Hospital, Third Military Medical University, Chongqing 400038, China
| | - Jiwei Yao
- Center for Neurointelligence, School of Medicine, Chongqing University, Chongqing 400030, China
| | - Xiang Liao
- Center for Neurointelligence, School of Medicine, Chongqing University, Chongqing 400030, China
| | - Min Chen
- Department of Urology, Southwest Hospital, Third Military Medical University, Chongqing 400038, China
| | - Jinliang Zhai
- Advanced Institute for Brain and Intelligence, School of Physical Science and Technology, Guangxi University, Nanning 530004, China
| | - Lang Lang
- Department of Urology, Southwest Hospital, Third Military Medical University, Chongqing 400038, China
| | - Chunyan Lin
- Department of Urology, Southwest Hospital, Third Military Medical University, Chongqing 400038, China
| | - Na Zhang
- Department of Urology, Southwest Hospital, Third Military Medical University, Chongqing 400038, China
| | - Chunhui Yuan
- Chongqing Institute for Brain and Intelligence, Guangyang Bay Laboratory, Chongqing 400064, China
| | - Chunxia Li
- Department of Urology, Southwest Hospital, Third Military Medical University, Chongqing 400038, China
| | - Hui Li
- Department of Urology, Southwest Hospital, Third Military Medical University, Chongqing 400038, China
| | - Xiaojun Wu
- Department of Urology, Southwest Hospital, Third Military Medical University, Chongqing 400038, China
| | - Jing Lin
- Department of Urology, Southwest Hospital, Third Military Medical University, Chongqing 400038, China
| | - Chunlian Li
- Department of Urology, Southwest Hospital, Third Military Medical University, Chongqing 400038, China
| | - Yan Wang
- Brain Research Instrument Innovation Center, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Jing Lyu
- Brain Research Instrument Innovation Center, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Min Li
- Brain Research Instrument Innovation Center, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Zhenqiao Zhou
- Brain Research Instrument Innovation Center, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Mengke Yang
- Brain Research Instrument Innovation Center, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China; UK Dementia Research Institute at UCL, University College London, WC1E 6BT London, UK.
| | - Hongbo Jia
- Advanced Institute for Brain and Intelligence, School of Physical Science and Technology, Guangxi University, Nanning 530004, China; Brain Research Instrument Innovation Center, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China; Leibniz Institute for Neurobiology, Magdeburg 39118, Germany.
| | - Junan Yan
- Department of Urology, Southwest Hospital, Third Military Medical University, Chongqing 400038, China; Center for Neurointelligence, School of Medicine, Chongqing University, Chongqing 400030, China; Chongqing Institute for Brain and Intelligence, Guangyang Bay Laboratory, Chongqing 400064, China.
| |
Collapse
|
3
|
Peer S, Vybornova A, Tauber J, Saracevic E, Krampe J, Zessner M, Zoboli O. To analyze or to throw away? On the stability of excitation-emission matrices for different water systems. CHEMOSPHERE 2023; 333:138853. [PMID: 37164201 DOI: 10.1016/j.chemosphere.2023.138853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 05/02/2023] [Accepted: 05/03/2023] [Indexed: 05/12/2023]
Abstract
Fluorescence spectroscopy has numerous applications to characterize natural and human-influenced water bodies regarding dissolved organic matter (DOM) and contamination. Analyzing samples in a timely manner is crucial to gaining valid and reproducible excitation-emission matrices (EEM) but often difficult, specifically in transnational projects with long transport distances. In this study, eight samples of different water sources (tap water, differently polluted rivers, and wastewater treatment plant (WWTP) effluents) were stored under standardized conditions for 59 days and analyzed regularly. With this data set, the sample and fluorescence spectra stability was evaluated. Established analysis methods such as peak picking and fluorescence metrics were compared over time and benchmarked against dissolved organic carbon (DOC) and a maximal change of 10% in terms of their variability. Additional high-performance liquid chromatography (HPLC) data to identify single organic compounds provides insights into these DOM alterations and allows for conclusions about the underlying biological processes. Our results corroborate in a systematic way that the higher the organic or microbial load, the faster the sample must be processed. For all water sources, considerable changes were found between days zero and one, indicating a potential systematic bias between in-situ and laboratory measurements. The absolute signals of individual peaks vary substantially after only a few days. In contrast, relative metrics are robust for a much longer time. For specific metrics, when filtered and stored under cool and dark conditions, tap water may be stored for up to 59 days, non-polluted river water for up to 31-59 days, and WWTP effluents for up to 14-59 days. The storability thus depends both on the specific water source and the analytical plan. By systematizing our understanding of how the specific water source and DOM concentration determine the stability of samples during storage, these conclusions facilitate efforts to establish a standardized protocol.
Collapse
Affiliation(s)
- Sandra Peer
- Institute for Water Quality and Resource Management, TU Wien, Karlsplatz 13/226, 1040, Vienna, Austria.
| | - Anastassia Vybornova
- Institute for Water Quality and Resource Management, TU Wien, Karlsplatz 13/226, 1040, Vienna, Austria; IT University of Copenhagen, Rued Langgaards Vej 7, 2300, Copenhagen, Denmark
| | - Joseph Tauber
- Institute for Water Quality and Resource Management, TU Wien, Karlsplatz 13/226, 1040, Vienna, Austria
| | - Ernis Saracevic
- Institute for Water Quality and Resource Management, TU Wien, Karlsplatz 13/226, 1040, Vienna, Austria
| | - Jörg Krampe
- Institute for Water Quality and Resource Management, TU Wien, Karlsplatz 13/226, 1040, Vienna, Austria
| | - Matthias Zessner
- Institute for Water Quality and Resource Management, TU Wien, Karlsplatz 13/226, 1040, Vienna, Austria
| | - Ottavia Zoboli
- Institute for Water Quality and Resource Management, TU Wien, Karlsplatz 13/226, 1040, Vienna, Austria
| |
Collapse
|