1
|
Pal S, Sharma A. How does the COVID-19-related restriction affect the spatiotemporal variability of ambient air quality in a tropical city? ENVIRONMENTAL MONITORING AND ASSESSMENT 2023; 195:847. [PMID: 37322089 DOI: 10.1007/s10661-023-11443-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Accepted: 06/01/2023] [Indexed: 06/17/2023]
Abstract
The ambient air, a significant hazard to human health in most Indian cities, including Rourkela, is something we are strangely neglecting in the age of industrialization and urbanization. High levels of particulate matter released from various anthropogenic sources over the past decade have had a significant negative impact on the city. The COVID-19 lockdown situation brings understanding and realization towards the improvement of air quality and its subsequent effects. The present study investigates the impact of the COVID-19-related lockdown on the spatiotemporal variation of the ambient air quality in Rourkela City with a tropical climatic setup. The concentration and distribution of various pollutants are well explained by the wind rose and Pearson correlation. There is considerable spatiotemporal variation in the city's ambient air quality, as determined by a two-way ANOVA test comparing sampling sites and months. During the COVID-19 lockdown phases, the air quality of Rourkela witnessed an improvement in annual AQI ranging from 12.64 to 26.85% across the city. However, the air quality in the city deteriorated by 13.76-65.79% after the revocation of COVID-19 restrictions. The paired sample T-test justified that the air quality of Rourkela was significantly healthier in 2020 compared to both 2019 and 2021. Spatial interpolation reveals that the ambient air quality of Rourkela ranged from satisfactory to moderate categories throughout the entire study period. 31.93% area of the city has experienced an improvement in AQI from the Moderate to the satisfying category from 2019 to 2020, whereas about 68.78% area of the city has witnessed a decline in AQI from satisfactory to moderate category from 2020 to 2021.
Collapse
Affiliation(s)
- Sudhakar Pal
- School of Geography, Gangadhar Meher University, Sambalpur, 768004, Odisha, India
| | - Arabinda Sharma
- School of Geography, Gangadhar Meher University, Sambalpur, 768004, Odisha, India.
| |
Collapse
|
2
|
Belmonte-Lopes R, Barquilha CER, Kozak C, Barcellos DS, Leite BZ, da Costa FJOG, Martins WL, Oliveira PE, Pereira EHRA, Filho CRM, de Souza EM, Possetti GRC, Vicente VA, Etchepare RG. 20-Month monitoring of SARS-CoV-2 in wastewater of Curitiba, in Southern Brazil. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023:10.1007/s11356-023-27926-x. [PMID: 37243767 DOI: 10.1007/s11356-023-27926-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Accepted: 05/22/2023] [Indexed: 05/29/2023]
Abstract
The COVID-19 pandemic resulted in the collapse of healthcare systems and led to the development and application of several approaches of wastewater-based epidemiology to monitor infected populations. The main objective of this study was to carry out a SARS-CoV-2 wastewater based surveillance in Curitiba, Southern Brazil Sewage samples were collected weekly for 20 months at the entrance of five treatment plants representing the entire city and quantified by qPCR using the N1 marker. The viral loads were correlated with epidemiological data. The correlation by sampling points showed that the relationship between the viral loads and the number of reported cases was best described by a cross-correlation function, indicating a lag between 7 and 14 days amidst the variables, whereas the data for the entire city presented a higher correlation (0.84) with the number of positive tests at lag 0 (sampling day). The results also suggest that the Omicron VOC resulted in higher titers than the Delta VOC. Overall, our results showed that the approach used was robust as an early warning system, even with the use of different epidemiological indicators or changes in the virus variants in circulation. Therefore, it can contribute to public decision-makers and health interventions, especially in vulnerable and low-income regions with limited clinical testing capacity. Looking toward the future, this approach will contribute to a new look at environmental sanitation and should even induce an increase in sewage coverage rates in emerging countries.
Collapse
Affiliation(s)
- Ricardo Belmonte-Lopes
- Graduate Program On Pathology, Parasitology, and Microbiology, Federal University of Paraná, 100 Coronel Francisco Heráclito Dos Santos Avenue, Curitiba, PR, 81530-000, Brazil
- Basic Pathology Department, Biological Sciences Sector, Microbiological Collections of Paraná Network, Room 135/136. 100 Coronel Francisco Heráclito Dos Santos Avenue, Curitiba, PR, 81530-000, Brazil
- Basic Pathology Department, Federal University of Paraná, 100 Coronel Francisco Heráclito Dos Santos Avenue, Curitiba, PR, 81530-000, Brazil
| | - Carlos E R Barquilha
- Graduate Program On Water Resources and Environmental Engineering, Hydraulics and Sanitation Department, Federal University of Paraná, 100 Coronel Francisco Heráclito Dos Santos Avenue, Curitiba, PR, 81530-000, Brazil
- Hydraulics and Sanitation Department, Federal University of Paraná, 100 Coronel Francisco Heráclito Dos Santos Avenue, Curitiba, PR, 81530-000, Brazil
| | - Caroline Kozak
- Environment Department, Maringa State University, SESI Block, 1800 Ângelo Moreira da Fonseca AvenueRoom 15, Parque Danielle, Umuarama, PR, 87506-370, Brazil
| | - Demian S Barcellos
- Hydraulics and Sanitation Department, Federal University of Paraná, 100 Coronel Francisco Heráclito Dos Santos Avenue, Curitiba, PR, 81530-000, Brazil
| | - Bárbara Z Leite
- Research and Innovation Management, Paraná Sanitation Company (SANEPAR), 1376 Eng. Rebouças St, Rebouças, Curitiba, PR, 80215-900, Brazil
| | - Fernanda J O Gomes da Costa
- Research and Innovation Management, Paraná Sanitation Company (SANEPAR), 1376 Eng. Rebouças St, Rebouças, Curitiba, PR, 80215-900, Brazil
| | - William L Martins
- Basic Pathology Department, Federal University of Paraná, 100 Coronel Francisco Heráclito Dos Santos Avenue, Curitiba, PR, 81530-000, Brazil
| | - Pâmela E Oliveira
- Hydraulics and Sanitation Department, Federal University of Paraná, 100 Coronel Francisco Heráclito Dos Santos Avenue, Curitiba, PR, 81530-000, Brazil
| | - Edy H R A Pereira
- Hydraulics and Sanitation Department, Federal University of Paraná, 100 Coronel Francisco Heráclito Dos Santos Avenue, Curitiba, PR, 81530-000, Brazil
| | - Cesar R Mota Filho
- Sanitary and Environmental Engineering Department, Federal University of Minas Gerais (UFMG), 6627 Antonio Carlos Avenue, Block 1, Room 4529, Belo Horizonte, MG, 31270-901, Brazil
| | - Emanuel M de Souza
- Biochemistry and Molecular Biology Department, Federal University of Paraná, 100 Coronel Francisco Heráclito Dos Santos Avenue, Curitiba, PR, 81530-000, Brazil
| | - Gustavo R C Possetti
- Research and Innovation Management, Paraná Sanitation Company (SANEPAR), 1376 Eng. Rebouças St, Rebouças, Curitiba, PR, 80215-900, Brazil
| | - Vania A Vicente
- Basic Pathology Department, Biological Sciences Sector, Microbiological Collections of Paraná Network, Room 135/136. 100 Coronel Francisco Heráclito Dos Santos Avenue, Curitiba, PR, 81530-000, Brazil
- Basic Pathology Department, Federal University of Paraná, 100 Coronel Francisco Heráclito Dos Santos Avenue, Curitiba, PR, 81530-000, Brazil
| | - Ramiro G Etchepare
- Hydraulics and Sanitation Department, Federal University of Paraná, 100 Coronel Francisco Heráclito Dos Santos Avenue, Curitiba, PR, 81530-000, Brazil.
| |
Collapse
|