Rusu DN, Cunningham JM, Arch JV, Chetty IJ, Parikh PJ, Dolan JL. Impact of intrafraction motion in pancreatic cancer treatments with MR-guided adaptive radiation therapy. Front Oncol 2023; 13:1298099. [PMID: 38162503 PMCID: PMC10756668 DOI: 10.3389/fonc.2023.1298099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Accepted: 11/27/2023] [Indexed: 01/03/2024] Open
Abstract
Purpose The total time of radiation treatment delivery for pancreatic cancer patients with daily online adaptive radiation therapy (ART) on an MR-Linac can range from 50 to 90 min. During this period, the target and normal tissues undergo changes due to respiration and physiologic organ motion. We evaluated the dosimetric impact of the intrafraction physiological organ changes. Methods Ten locally advanced pancreatic cancer patients were treated with 50 Gy in five fractions with intensity-modulated respiratory-gated radiation therapy on a 0.35-T MR-Linac. Patients received both pre- and post-treatment volumetric MRIs for each fraction. Gastrointestinal organs at risk (GI-OARs) were delineated on the pre-treatment MRI during the online ART process and retrospectively on the post-treatment MRI. The treated dose distribution for each adaptive plan was assessed on the post-treatment anatomy. Prescribed dose volume histogram metrics for the scheduled plan on the pre-treatment anatomy, the adapted plan on the pre-treatment anatomy, and the adapted plan on post-treatment anatomy were compared to the OAR-defined criteria for adaptation: the volume of the GI-OAR receiving greater than 33 Gy (V33Gy) should be ≤1 cubic centimeter. Results Across the 50 adapted plans for the 10 patients studied, 70% were adapted to meet the duodenum constraint, 74% for the stomach, 12% for the colon, and 48% for the small bowel. Owing to intrafraction organ motion, at the time of post-treatment imaging, the adaptive criteria were exceeded for the duodenum in 62% of fractions, the stomach in 36%, the colon in 10%, and the small bowel in 48%. Compared to the scheduled plan, the post-treatment plans showed a decrease in the V33Gy, demonstrating the benefit of plan adaptation for 66% of the fractions for the duodenum, 95% for the stomach, 100% for the colon, and 79% for the small bowel. Conclusion Post-treatment images demonstrated that over the course of the adaptive plan generation and delivery, the GI-OARs moved from their isotoxic low-dose region and nearer to the dose-escalated high-dose region, exceeding dose-volume constraints. Intrafraction motion can have a significant dosimetric impact; therefore, measures to mitigate this motion are needed. Despite consistent intrafraction motion, plan adaptation still provides a dosimetric benefit.
Collapse
Affiliation(s)
- Doris N. Rusu
- Department of Radiation Oncology, Wayne State University, Detroit, MI, United States
- Department of Radiation Oncology, Henry Ford Health System, Detroit, MI, United States
| | - Justine M. Cunningham
- Department of Radiation Oncology, Henry Ford Health System, Detroit, MI, United States
| | - Jacob V. Arch
- Department of Radiation Oncology, Henry Ford Health System, Detroit, MI, United States
| | - Indrin J. Chetty
- Department of Radiation Oncology, Henry Ford Health System, Detroit, MI, United States
- Department of Radiation Oncology, Cedars Sinai Medical Center, Los Angeles, CA, United States
| | - Parag J. Parikh
- Department of Radiation Oncology, Henry Ford Health System, Detroit, MI, United States
| | - Jennifer L. Dolan
- Department of Radiation Oncology, Henry Ford Health System, Detroit, MI, United States
| |
Collapse
|
2
|
Bryant JM, Weygand J, Keit E, Cruz-Chamorro R, Sandoval ML, Oraiqat IM, Andreozzi J, Redler G, Latifi K, Feygelman V, Rosenberg SA. Stereotactic Magnetic Resonance-Guided Adaptive and Non-Adaptive Radiotherapy on Combination MR-Linear Accelerators: Current Practice and Future Directions. Cancers (Basel) 2023; 15:2081. [PMID: 37046741 PMCID: PMC10093051 DOI: 10.3390/cancers15072081] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 03/27/2023] [Accepted: 03/29/2023] [Indexed: 04/03/2023] Open
Abstract
Stereotactic body radiotherapy (SBRT) is an effective radiation therapy technique that has allowed for shorter treatment courses, as compared to conventionally dosed radiation therapy. As its name implies, SBRT relies on daily image guidance to ensure that each fraction targets a tumor, instead of healthy tissue. Magnetic resonance imaging (MRI) offers improved soft-tissue visualization, allowing for better tumor and normal tissue delineation. MR-guided RT (MRgRT) has traditionally been defined by the use of offline MRI to aid in defining the RT volumes during the initial planning stages in order to ensure accurate tumor targeting while sparing critical normal tissues. However, the ViewRay MRIdian and Elekta Unity have improved upon and revolutionized the MRgRT by creating a combined MRI and linear accelerator (MRL), allowing MRgRT to incorporate online MRI in RT. MRL-based MR-guided SBRT (MRgSBRT) represents a novel solution to deliver higher doses to larger volumes of gross disease, regardless of the proximity of at-risk organs due to the (1) superior soft-tissue visualization for patient positioning, (2) real-time continuous intrafraction assessment of internal structures, and (3) daily online adaptive replanning. Stereotactic MR-guided adaptive radiation therapy (SMART) has enabled the safe delivery of ablative doses to tumors adjacent to radiosensitive tissues throughout the body. Although it is still a relatively new RT technique, SMART has demonstrated significant opportunities to improve disease control and reduce toxicity. In this review, we included the current clinical applications and the active prospective trials related to SMART. We highlighted the most impactful clinical studies at various tumor sites. In addition, we explored how MRL-based multiparametric MRI could potentially synergize with SMART to significantly change the current treatment paradigm and to improve personalized cancer care.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | - Stephen A. Rosenberg
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL 33612, USA; (J.M.B.)
| |
Collapse
|
3
|
Bryant JM, Sim AJ, Feygelman V, Latifi K, Rosenberg SA. Adaptive hypofractionted and stereotactic body radiotherapy for lung tumors with real-time MRI guidance. Front Oncol 2023; 13:1061854. [PMID: 36776319 PMCID: PMC9911810 DOI: 10.3389/fonc.2023.1061854] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 01/03/2023] [Indexed: 01/28/2023] Open
Abstract
The treatment of central and ultracentral lung tumors with radiotherapy remains an ongoing clinical challenge. The risk of Grade 5 toxicity with ablative radiotherapy doses to these high-risk regions is significant as shown in recent prospective studies. Magnetic resonance (MR) image-guided adaptive radiotherapy (MRgART) is a new technology and may allow the delivery of ablative radiotherapy to these high-risk regions safely. MRgART is able to achieve this by utilizing small treatment margins, real-time gating/tracking and on-table plan adaptation to maintain dose to the tumor but limit dose to critical structures. The process of MRgART is complex and has nuances and challenges for the treatment of lung tumors. We outline the critical steps needed for appropriate delivery of MRgART for lung tumors safely and effectively.
Collapse
Affiliation(s)
- John M. Bryant
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, United States
| | - Austin J. Sim
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, United States,Department of Radiation Oncology, Comprehensive Cancer Center – The James Cancer Hospital, Columbus, OH, United States
| | - Vladimir Feygelman
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, United States
| | - Kujtim Latifi
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, United States
| | - Stephen A. Rosenberg
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, United States,*Correspondence: Stephen A. Rosenberg,
| |
Collapse
|
4
|
Hall WA, Small C, Paulson E, Koay EJ, Crane C, Intven M, Daamen LA, Meijer GJ, Heerkens HD, Bassetti M, Rosenberg SA, Aitken K, Myrehaug S, Dawson LA, Lee P, Gani C, Chuong MD, Parikh PJ, Erickson BA. Magnetic Resonance Guided Radiation Therapy for Pancreatic Adenocarcinoma, Advantages, Challenges, Current Approaches, and Future Directions. Front Oncol 2021; 11:628155. [PMID: 34046339 PMCID: PMC8144850 DOI: 10.3389/fonc.2021.628155] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Accepted: 03/03/2021] [Indexed: 12/15/2022] Open
Abstract
Introduction Pancreatic adenocarcinoma (PAC) has some of the worst treatment outcomes for any solid tumor. PAC creates substantial difficulty for effective treatment with traditional RT delivery strategies primarily secondary to its location and limited visualization using CT. Several of these challenges are uniquely addressed with MR-guided RT. We sought to summarize and place into context the currently available literature on MR-guided RT specifically for PAC. Methods A literature search was conducted to identify manuscript publications since September 2014 that specifically used MR-guided RT for the treatment of PAC. Clinical outcomes of these series are summarized, discussed, and placed into the context of the existing pancreatic literature. Multiple international experts were involved to optimally contextualize these publications. Results Over 300 manuscripts were reviewed. A total of 6 clinical outcomes publications were identified that have treated patients with PAC using MR guidance. Successes, challenges, and future directions for this technology are evident in these publications. MR-guided RT holds theoretical promise for the treatment of patients with PAC. As with any new technology, immediate or dramatic clinical improvements associated with its use will take time and experience. There remain no prospective trials, currently publications are limited to small retrospective experiences. The current level of evidence for MR guidance in PAC is low and requires significant expansion. Future directions and ongoing studies that are currently open and accruing are identified and reviewed. Conclusions The potential promise of MR-guided RT for PAC is highlighted, the challenges associated with this novel therapeutic intervention are also reviewed. Outcomes are very early, and will require continued and long term follow up. MR-guided RT should not be viewed in the same fashion as a novel chemotherapeutic agent for which dosing, administration, and toxicity has been established in earlier phase studies. Instead, it should be viewed as a novel procedural intervention which must be robustly tested, refined and practiced before definitive conclusions on the potential benefits or detriments can be determined. The future of MR-guided RT for PAC is highly promising and the potential implications on PAC are substantial.
Collapse
Affiliation(s)
- William A Hall
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI, United States
| | - Christina Small
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI, United States
| | - Eric Paulson
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI, United States
| | - Eugene J Koay
- Division of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Christopher Crane
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| | - Martijn Intven
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Lois A Daamen
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Gert J Meijer
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Hanne D Heerkens
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Michael Bassetti
- Department of Radiation Oncology, University of Wisconsin-Madison, Madison, WI, United States
| | - Stephen A Rosenberg
- Department of Radiation Oncology, Moffitt Cancer Center, Tampa, FL, United States
| | - Katharine Aitken
- Department of Radiation Oncology, Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Sten Myrehaug
- Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | - Laura A Dawson
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON, Canada
| | - Percy Lee
- Division of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Cihan Gani
- Department of Radiation Oncology, Faculty of Medicine, University of Tübingen, Tübingen, Germany
| | | | - Parag J Parikh
- Henry Ford Medical Center, Henry Ford Health System, Detroit, MI, United States
| | - Beth A Erickson
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI, United States
| |
Collapse
|
5
|
Thorwarth D, Low DA. Technical Challenges of Real-Time Adaptive MR-Guided Radiotherapy. Front Oncol 2021; 11:634507. [PMID: 33763369 PMCID: PMC7982516 DOI: 10.3389/fonc.2021.634507] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Accepted: 01/26/2021] [Indexed: 12/18/2022] Open
Abstract
In the past few years, radiotherapy (RT) has experienced a major technological innovation with the development of hybrid machines combining magnetic resonance (MR) imaging and linear accelerators. This new technology for MR-guided cancer treatment has the potential to revolutionize the field of adaptive RT due to the opportunity to provide high-resolution, real-time MR imaging before and during treatment application. However, from a technical point of view, several challenges remain which need to be tackled to ensure safe and robust real-time adaptive MR-guided RT delivery. In this manuscript, several technical challenges to MR-guided RT are discussed. Starting with magnetic field strength tradeoffs, the potential and limitations for purely MR-based RT workflows are discussed. Furthermore, the current status of real-time 3D MR imaging and its potential for real-time RT are summarized. Finally, the potential of quantitative MR imaging for future biological RT adaptation is highlighted.
Collapse
Affiliation(s)
- Daniela Thorwarth
- Section for Biomedical Physics, Department of Radiation Oncology, University of Tübingen, Tübingen, Germany
| | - Daniel A Low
- Department of Radiation Oncology, University of California, Los Angeles, Los Angeles, CA, United States
| |
Collapse
|
6
|
Cardenas CE, Mohamed ASR, Yang J, Gooding M, Veeraraghavan H, Kalpathy-Cramer J, Ng SP, Ding Y, Wang J, Lai SY, Fuller CD, Sharp G. Head and neck cancer patient images for determining auto-segmentation accuracy in T2-weighted magnetic resonance imaging through expert manual segmentations. Med Phys 2021; 47:2317-2322. [PMID: 32418343 DOI: 10.1002/mp.13942] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2019] [Revised: 11/15/2019] [Accepted: 12/01/2019] [Indexed: 11/10/2022] Open
Abstract
PURPOSE The use of magnetic resonance imaging (MRI) in radiotherapy treatment planning has rapidly increased due to its ability to evaluate patient's anatomy without the use of ionizing radiation and due to its high soft tissue contrast. For these reasons, MRI has become the modality of choice for longitudinal and adaptive treatment studies. Automatic segmentation could offer many benefits for these studies. In this work, we describe a T2-weighted MRI dataset of head and neck cancer patients that can be used to evaluate the accuracy of head and neck normal tissue auto-segmentation systems through comparisons to available expert manual segmentations. ACQUISITION AND VALIDATION METHODS T2-weighted MRI images were acquired for 55 head and neck cancer patients. These scans were collected after radiotherapy computed tomography (CT) simulation scans using a thermoplastic mask to replicate patient treatment position. All scans were acquired on a single 1.5 T Siemens MAGNETOM Aera MRI with two large four-channel flex phased-array coils. The scans covered the region encompassing the nasopharynx region cranially and supraclavicular lymph node region caudally, when possible, in the superior-inferior direction. Manual contours were created for the left/right submandibular gland, left/right parotids, left/right lymph node level II, and left/right lymph node level III. These contours underwent quality assurance to ensure adherence to predefined guidelines, and were corrected if edits were necessary. DATA FORMAT AND USAGE NOTES The T2-weighted images and RTSTRUCT files are available in DICOM format. The regions of interest are named based on AAPM's Task Group 263 nomenclature recommendations (Glnd_Submand_L, Glnd_Submand_R, LN_Neck_II_L, Parotid_L, Parotid_R, LN_Neck_II_R, LN_Neck_III_L, LN_Neck_III_R). This dataset is available on The Cancer Imaging Archive (TCIA) by the National Cancer Institute under the collection "AAPM RT-MAC Grand Challenge 2019" (https://doi.org/10.7937/tcia.2019.bcfjqfqb). POTENTIAL APPLICATIONS This dataset provides head and neck patient MRI scans to evaluate auto-segmentation systems on T2-weighted images. Additional anatomies could be provided at a later time to enhance the existing library of contours.
Collapse
Affiliation(s)
- Carlos E Cardenas
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Abdallah S R Mohamed
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.,MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, TX, USA
| | - Jinzhong Yang
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | | | - Harini Veeraraghavan
- Department of Medical Physics, Memorial Sloan Kettering Cancer Centre, New York, NY, USA
| | | | - Sweet Ping Ng
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.,Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Australia
| | - Yao Ding
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Jihong Wang
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Stephen Y Lai
- Department of Head and Neck Surgery, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Clifton D Fuller
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Greg Sharp
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
7
|
Musunuru HB, Yadav P, Olson SJ, Anderson BM. Improved Ipsilateral Breast and Chest Wall Sparing With MR-Guided 3-fraction Accelerated Partial Breast Irradiation: A Dosimetric Study Comparing MR-Linac and CT-Linac Plans. Adv Radiat Oncol 2021; 6:100654. [PMID: 34195491 PMCID: PMC8233460 DOI: 10.1016/j.adro.2021.100654] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 11/11/2020] [Accepted: 12/15/2020] [Indexed: 01/21/2023] Open
Abstract
Purpose External beam accelerated partial breast irradiation (APBI) is subject to treatment uncertainties that must be accounted for through planning target volume (PTV) margin. We hypothesize that magnetic resonance–guided radiation therapy with reduced PTV margins enabled by real-time cine magnetic resonance image (MRI) target monitoring results in better normal tissue sparing compared with computed tomography (CT)-guided radiation therapy with commonly used clinical PTV margins. In this study, we compare the plan quality of ViewRay MRIdian Linac forward planned intensity modulated radiation therapy and TrueBeam volumetric modulated arc therapy for a novel 3-fraction APBI schedule. Methods and Materials Targets and organs at risk (OARs) were segmented for 10 patients with breast cancer according to NSABP B39/RTOG 0413 protocol. A 3 mm margin was used to generate MR PTV3mm and CT PTV3mm plans, and a 10 mm margin was used for CT PTV10mm. An APBI schedule delivering 24.6 Gy to the clinical target volume and 23.4 Gy to the PTV in 3 fractions was used. OAR dose constraints were scaled down from existing 5-fraction APBI protocols. Target and OAR dose-volume metrics for the following data sets were analyzed using Wilcoxon matched-pairs signed-rank test: (1) MR PTV3mm versus CT PTV3mm plans and (2) MR PTV3mm versus CT PTV10mm. Results Average PTVs were 84.3 ± 51.9 cm3 and 82.6 ± 55 cm3 (P = .5) for MR PTV3mm and CT PTV3mm plans, respectively. PTV V23.4Gy, dose homogeneity index, conformity index (CI), and R50 were similar. There was no meaningful difference in OAR metrics, despite MR PTV3mm being larger than the CT PTV3mm in 70% of the patients. Average PTVs for MR PTV3mm and CT PTV10mm plans were 84.3 ± 51.9 cm3 and 131.7 ± 74.4 cm3, respectively (P = .002). PTV V23.4Gy was 99% ± 0.9% versus 97.6% ± 1.4% (P = .03) for MR PTV3mm and CT PTV10mm, respectively. Dose homogeneity index, CI, and R50 were similar. MR PTV3mm plans had better ipsilateral breast (V12.3Gy, 34.8% ± 12.7% vs 44.4% ± 10.9%, P = .002) and chest wall sparing (V24Gy, 8.5 ± 5.5 cm3 vs 21.8 ± 14.9 cm3, P = .004). Conclusions MR- and CT-based planning systems produced comparable plans when a 3 mm PTV margin was used for both plans. As expected, MR PTV3mm plans produced better ipsilateral breast and chest wall sparing compared with CT PTV10mm. The clinical relevance of these differences in dosimetric parameters is not known.
Collapse
Affiliation(s)
- Hima Bindu Musunuru
- Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
- Department of Radiation Oncology, UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania
- Corresponding author: Hima Bindu Musunuru, MD
| | - Poonam Yadav
- Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | - Stephanie J. Olson
- Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | - Bethany M. Anderson
- Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| |
Collapse
|
8
|
Eccles C, Adair Smith G, Bower L, Hafeez S, Herbert T, Hunt A, McNair H, Ofuya M, Oelfke U, Nill S, Huddart R. Magnetic resonance imaging sequence evaluation of an MR Linac system; early clinical experience. Tech Innov Patient Support Radiat Oncol 2019; 12:56-63. [PMID: 32095556 PMCID: PMC7033780 DOI: 10.1016/j.tipsro.2019.11.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2019] [Revised: 11/06/2019] [Accepted: 11/11/2019] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVES To systematically identify the preferred magnetic resonance imaging (MRI) sequences following volunteer imaging on a 1.5 Tesla (T) MR-Linear Accelerator (MR Linac) for future protocol development. METHODS Non-patient volunteers were recruited to a Research and Ethics committee approved prospective MR-only imaging study on a 1.5T MR Linac system. Volunteers attended 1-3 imaging sessions that included a combination of mDixon, T1w, T2w sequences using 2-dimensional (2D) and 3-dimensional (3D) acquisitions. Each sequence was acquired over 2-7 minutes and reviewed by a panel of 3 observers to evaluate image quality using a visual grading analysis based on a 4-point Likert scale. Sequences were acquired and modified iteratively until deemed fit for purpose (online image matching or re-planning) and all observers agreed they were suitable in 3 volunteers. RESULTS 26 volunteers underwent 31 imaging sessions of six general anatomical regions. Images were acquired in one or two of six general anatomical regions: male pelvis (n = 9), female pelvis (n = 4), chestwall/breast (n = 5), lung/oesophagus (n = 5), abdomen (n = 3) and head and neck (n = 5). Images were acquired using a pre-defined exam-card that on average, included six sequences (range 2-10), with a maximum scan time of approximately one hour. The majority of observers preferred T2-weighted sequences. The thorax teams were the only groups to prefer T1-weighted imaging. CONCLUSIONS An iterative process identified sequence agreement in all anatomical regions. These sequences will now be evaluated in patient volunteers. ADVANCES IN KNOWLEDGE This manuscript is the first publication sharing the results of the first systematic selection of MRI sequences for use in on-board MRI-guided radiotherapy by end-users (therapeutic radiographers and clinical oncologists) in healthy volunteers.
Collapse
Affiliation(s)
- C.L. Eccles
- The Royal Marsden NHS Foundation Trust, London, United Kingdom
- The Christie NHS Foundation Trust, and the University of Manchester, Manchester, United Kingdom
| | - G. Adair Smith
- The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - L. Bower
- The Royal Marsden NHS Foundation Trust, London, United Kingdom
- The Institute of Cancer Research/The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - S. Hafeez
- The Royal Marsden NHS Foundation Trust, London, United Kingdom
- The Institute of Cancer Research/The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - T. Herbert
- The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - A. Hunt
- The Royal Marsden NHS Foundation Trust, London, United Kingdom
- The Institute of Cancer Research/The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - H.A. McNair
- The Royal Marsden NHS Foundation Trust, London, United Kingdom
- The Institute of Cancer Research/The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Mercy Ofuya
- Clinical Trials and Statistic Unit, The Institute for Cancer Research, London, United Kingdom
| | - Uwe Oelfke
- Joint Department of Physics at the Royal Marsden and The Institute of Cancer Research, United Kingdom
| | - Simeon Nill
- Joint Department of Physics at the Royal Marsden and The Institute of Cancer Research, United Kingdom
| | - R.A. Huddart
- The Royal Marsden NHS Foundation Trust, London, United Kingdom
- The Institute of Cancer Research/The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | | |
Collapse
|
9
|
Dosimetric study for spine stereotactic body radiation therapy: magnetic resonance guided linear accelerator versus volumetric modulated arc therapy. Radiol Oncol 2019; 53:362-368. [PMID: 31553704 PMCID: PMC6765155 DOI: 10.2478/raon-2019-0042] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2019] [Accepted: 07/22/2019] [Indexed: 12/13/2022] Open
Abstract
Background Stereotactic body radiation therapy (SBRT) given in 1-5 fractions is an effective treatment for vertebral metastases. Real-time magnetic resonance-guided radiotherapy (MRgRT) improves soft tissue contrast, which translates into accurate delivery of spine SBRT. Here we report on clinical implementation of MRgRT for spine SBRT, the quality of MRgRT plans compared to TrueBeam based volumetric modulated arc therapy (VMAT) plans in the treatment of spine metastases and benefits of MRgRT MR scan. Patients and methods Ten metastatic lesions were included in this study for plan comparison. Lesions were spread across thoracic spine and lumbosacral spine. Three fraction spine SBRT plans: 27Gy to planning target volume (PTV) and 30Gy to gross tumor volume (GTV) were generated on the ViewRay MRIdian Linac system and compared to TrueBeamTM STx based VMAT plans. Plans were compared using metrics such as minimum dose, maximum dose, mean dose, ratio of the dose to 50% of the volume (R50), conformity index, homogeneity index and dose to the spinal cord. Results MRIdian plans achieved equivalent target coverage and spinal cord dose compared to VMAT plans. The maximum and minimum PTV doses and homogeneity index were equivalent for both planning systems. R50 was lower for MRIdian plans compared to VMAT plans, indicating a lower spread of intermediate doses with MRIdian system (5.16 vs. 6.11, p = 0.03). Conclusions MRgRT can deliver high-quality spine SBRT plans comparable to TrueBeam volumetric modulated arc therapy (VMAT) plans.
Collapse
|
10
|
MRI basics for radiation oncologists. Clin Transl Radiat Oncol 2019; 18:74-79. [PMID: 31341980 PMCID: PMC6630156 DOI: 10.1016/j.ctro.2019.04.008] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Revised: 04/09/2019] [Accepted: 04/09/2019] [Indexed: 02/01/2023] Open
Abstract
Issues of MRI that are relevant for radiation oncologists are addressed. Radiation oncology requires dedicated scan protocols. Use of diagnostic protocols is not recommended for radiotherapy. MR images must be made in treatment position with the standard positioning devices. Safety screening prior to entering the MRI room is crucial.
MRI is increasingly used in radiation oncology to facilitate tumor and organ-at-risk delineation and image guidance. In this review, we address issues of MRI that are relevant for radiation oncologists when interpreting MR images offered for radiotherapy. Whether MRI is used in combination with CT or in an MRI-only workflow, it is generally necessary to ensure that MR images are acquired in treatment position, using the positioning and fixation devices that are commonly applied in radiotherapy. For target delineation, often a series of separate image sets are used with distinct image contrasts, acquired within a single exam. MR images can suffer from image distortions. While this can be avoided with dedicated scan protocols, in a diagnostic setting geometrical fidelity is less relevant and is therefore less accounted for. Since geometrical fidelity is of utmost importance in radiation oncology, it requires dedicated scan protocols. The strong magnetic field of an MRI scanner and the use of radiofrequency radiation can cause safety hazards if not properly addressed. Safety screening is crucial for every patient and every operator prior to entering the MRI room.
Collapse
|
11
|
Eccles CL, Campbell M. Keeping Up with the Hybrid Magnetic Resonance Linear Accelerators: How Do Radiation Therapists Stay Current in the Era of Hybrid Technologies? J Med Imaging Radiat Sci 2019; 50:195-198. [PMID: 31064719 DOI: 10.1016/j.jmir.2019.04.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Revised: 03/30/2019] [Accepted: 04/01/2019] [Indexed: 01/09/2023]
Abstract
The benefits of integrating magnetic resonance imaging (MRI) into radiotherapy planning have long been extolled, first appearing in the literature as early as 1986. Most often described as a tool to be used when registered to a planning computed tomography to improve target and organ at risk delineation, the use of MRI for on-board image guidance and as a sole imaging modality throughout the entire radiotherapy pathway is quickly becoming a reality for appropriately selected patient populations in academic centres throughout the world. With the commercialization of these integrated magnetic resonance - radiotherapy delivery systems, an MRI-only workflow will prove beneficial, with MRI being used for treatment planning, localization, and on-treatment plan adaptation. Despite these technological advancements, recent surveys indicate uptake of MRI in radiotherapy as a routine practice has proven challenging. Reasons cited for this slow uptake were primarily related to health economics and/or accessibility. Furthermore, these surveys, like much of the academic literature, shy away from focusing on safe, sustainable staffing models enabled by comprehensive and appropriate education and training. In stark contrast to conebeam computed tomography guided therapy, magnetic resonance - radiotherapy systems are currently being operated by teams of physicians, radiographers, and physicists because of the diverse and complex tasks required to deliver treatment. The pace of innovation in RT remains high and unfortunately the window of opportunity to implement appropriate education continues to narrow. It is vital that we establish a framework to future-proof our profession. In the era of magnetic resonance-guided radiotherapy, we have yet to address the question of how to devise a consensus on the requisite knowledge, skills, and competence for radiation therapists and therapy radiographers using and/or operating MRI that provides guidance, without becoming prohibitively costly or time consuming.
Collapse
Affiliation(s)
- Cynthia L Eccles
- Department of Radiotherapy, The Christie NHS Foundation Trust and Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK.
| | - Mikki Campbell
- Radiation Treatment Program, Odette Cancer Centre at Sunnybrook Health Sciences Centre, Toronto, Canada
| |
Collapse
|
12
|
Stemkens B, Paulson ES, Tijssen RHN. Nuts and bolts of 4D-MRI for radiotherapy. ACTA ACUST UNITED AC 2018; 63:21TR01. [DOI: 10.1088/1361-6560/aae56d] [Citation(s) in RCA: 74] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
13
|
Kerkmeijer LGW, Maspero M, Meijer GJ, van der Voort van Zyp JRN, de Boer HCJ, van den Berg CAT. Magnetic Resonance Imaging only Workflow for Radiotherapy Simulation and Planning in Prostate Cancer. Clin Oncol (R Coll Radiol) 2018; 30:692-701. [PMID: 30244830 DOI: 10.1016/j.clon.2018.08.009] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2018] [Revised: 06/29/2018] [Accepted: 08/21/2018] [Indexed: 01/06/2023]
Abstract
Magnetic resonance imaging (MRI) is often combined with computed tomography (CT) in prostate radiotherapy to optimise delineation of the target and organs-at-risk (OAR) while maintaining accurate dose calculation. Such a dual-modality workflow requires two separate imaging sessions, and it has some fundamental and logistical drawbacks. Due to the availability of new MRI hardware and software solutions, CT examinations can be omitted for prostate radiotherapy simulations. All information for treatment planning, including electron density maps and bony anatomy, can nowadays be obtained with MRI. Such an MRI-only simulation workflow reduces delineation ambiguities, eases planning logistics, and improves patient comfort; however, careful validation of the complete MRI-only workflow is warranted. The first institutes are now adopting this MRI-only workflow for prostate radiotherapy. In this article, we will review technology and workflow requirements for an MRI-only prostate simulation workflow.
Collapse
Affiliation(s)
- L G W Kerkmeijer
- Department of Radiotherapy, University Medical Center Utrecht, The Netherlands.
| | - M Maspero
- Department of Radiotherapy, University Medical Center Utrecht, The Netherlands
| | - G J Meijer
- Department of Radiotherapy, University Medical Center Utrecht, The Netherlands
| | | | - H C J de Boer
- Department of Radiotherapy, University Medical Center Utrecht, The Netherlands
| | - C A T van den Berg
- Department of Radiotherapy, University Medical Center Utrecht, The Netherlands
| |
Collapse
|
14
|
Cusumano D, Dhont J, Boldrini L, Chiloiro G, Teodoli S, Massaccesi M, Fionda B, Cellini F, Azario L, Vandemeulebroucke J, De Spirito M, Valentini V, Verellen D. Predicting tumour motion during the whole radiotherapy treatment: a systematic approach for thoracic and abdominal lesions based on real time MR. Radiother Oncol 2018; 129:456-462. [PMID: 30144955 DOI: 10.1016/j.radonc.2018.07.025] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Revised: 07/06/2018] [Accepted: 07/29/2018] [Indexed: 01/07/2023]
Abstract
INTRODUCTION Aim of this study was to investigate the ability of pre-treatment four dimensional computed tomography (4DCT) to capture respiratory-motion observed in thoracic and abdominal lesions during treatment. Treatment motion was acquired using full-treatment cine-MR acquisitions. Results of this analysis were compared to the ability of 30 seconds (s) cine Magnetic Resonance (MR) to estimate the same parameters. METHODS A 4DCT and 30 s cine-MR (ViewRay, USA) were acquired on the simulation day for 7 thoracic and 13 abdominal lesions. Mean amplitude, intra- and inter-fraction amplitude variability, and baseline drift were extracted from the full treatment data acquired by 2D cine-MR, and correlated to the motion on pre-treatment 30 s cine-MR and 4DCT. Using the full treatment data, safety margins on the ITV, necessary to account for all motion variability from 4DCT observed during treatment, were calculated. Mean treatment amplitudes were 2 ± 1 mm and 5 ± 3 mm in the anteroposterior (AP) and craniocaudal (CC) direction, respectively. Differences between mean amplitude during treatment and amplitude on 4DCT or during 30 s cine-MR were not significant, but 30 s cine-MR was more accurate than 4DCT. Intra-fraction amplitude variability was positively correlated with both 30 s cine-MR and 4DCT amplitude. Inter-fraction amplitude variability was minimal. RESULTS Mean baseline drift over all fractions and patients equalled 1 ± 1 mm in both CC and AP direction, but drifts per fraction up to 16 mm (CC) and 12 mm (AP) were observed. Margins necessary on the ITV ranged from 0 to 8 mm in CC and 0 to 5 mm in AP direction. Neither amplitude on 4DCT nor during 30 s cine MR is correlated to the magnitude of drift or the necessary margins in both directions. CONCLUSION Lesions moving with small amplitude show limited amplitude variability throughout treatment, making passive motion management strategies seem adequate. However, other variations such as baseline drifts and shifts still cause significant geometrical uncertainty, favouring real-time monitoring and an active approach for all lesions influenced by respiratory motion.
Collapse
Affiliation(s)
- Davide Cusumano
- U.O.C. Fisica Sanitaria, Dipartimento di Diagnostica per immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Roma, Italia; Istituto di Radiologia, Università Cattolica del Sacro Cuore, Roma, Italia
| | - Jennifer Dhont
- Vrije Universiteit Brussel (VUB), Faculty of Medicine and Pharmacy, Pleinlaan 2, B-1050 Brussels, Belgium; Vrije Universiteit Brussel (VUB), Department of Electronics and Informatics (ETRO), Pleinlaan 2, B-1050 Brussels, Belgium; imec, Kapeldreef 75, B-3001 Leuven, Belgium
| | - Luca Boldrini
- Istituto di Radiologia, Università Cattolica del Sacro Cuore, Roma, Italia.
| | - Giuditta Chiloiro
- Istituto di Radiologia, Università Cattolica del Sacro Cuore, Roma, Italia; U.O.C. Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A.Gemelli" IRCCS, Roma, Italia
| | - Stefania Teodoli
- U.O.C. Fisica Sanitaria, Dipartimento di Diagnostica per immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Roma, Italia
| | - Mariangela Massaccesi
- U.O.C. Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A.Gemelli" IRCCS, Roma, Italia
| | - Bruno Fionda
- U.O.C. Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A.Gemelli" IRCCS, Roma, Italia
| | - Francesco Cellini
- U.O.C. Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A.Gemelli" IRCCS, Roma, Italia
| | - Luigi Azario
- U.O.C. Fisica Sanitaria, Dipartimento di Diagnostica per immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Roma, Italia; Istituto di Fisica, Università Cattolica del Sacro Cuore, Roma, Italia
| | - Jef Vandemeulebroucke
- Vrije Universiteit Brussel (VUB), Department of Electronics and Informatics (ETRO), Pleinlaan 2, B-1050 Brussels, Belgium; imec, Kapeldreef 75, B-3001 Leuven, Belgium
| | - Marco De Spirito
- U.O.C. Fisica Sanitaria, Dipartimento di Diagnostica per immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Roma, Italia; Istituto di Fisica, Università Cattolica del Sacro Cuore, Roma, Italia
| | - Vincenzo Valentini
- Istituto di Radiologia, Università Cattolica del Sacro Cuore, Roma, Italia; U.O.C. Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A.Gemelli" IRCCS, Roma, Italia
| | - Dirk Verellen
- Vrije Universiteit Brussel (VUB), Faculty of Medicine and Pharmacy, Pleinlaan 2, B-1050 Brussels, Belgium; Department of Radiotherapy, GZA Ziekenhuizen - Sint Augustinus, Iridium Kankernetwerk, Antwerp, Belgium
| |
Collapse
|
15
|
Jaffray DA, Chung C, Coolens C, Foltz W, Keller H, Menard C, Milosevic M, Publicover J, Yeung I. Quantitative Imaging in Radiation Oncology: An Emerging Science and Clinical Service. Semin Radiat Oncol 2015; 25:292-304. [PMID: 26384277 DOI: 10.1016/j.semradonc.2015.05.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Radiation oncology has long required quantitative imaging approaches for the safe and effective delivery of radiation therapy. The past 10 years has seen a remarkable expansion in the variety of novel imaging signals and analyses that are starting to contribute to the prescription and design of the radiation treatment plan. These include a rapid increase in the use of magnetic resonance imaging, development of contrast-enhanced imaging techniques, integration of fluorinated deoxyglucose-positron emission tomography, evaluation of hypoxia imaging techniques, and numerous others. These are reviewed with an effort to highlight challenges related to quantification and reproducibility. In addition, several of the emerging applications of these imaging approaches are also highlighted. Finally, the growing community of support for establishing quantitative imaging approaches as we move toward clinical evaluation is summarized and the need for a clinical service in support of the clinical science and delivery of care is proposed.
Collapse
Affiliation(s)
- David Anthony Jaffray
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada; Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada.
| | - Caroline Chung
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Catherine Coolens
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada; Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Warren Foltz
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Harald Keller
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Cynthia Menard
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Michael Milosevic
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Julia Publicover
- TECHNA Institute/University Health Network, Toronto, Ontario, Canada
| | - Ivan Yeung
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|