1
|
KOIZUMI N, NISHIYAMA R, MASADOME T. Sequential Injection Analysis of Butyrylcholinesterase Using Butyrylcholine Ion-Selective Electrode Detector. ELECTROCHEMISTRY 2022. [DOI: 10.5796/electrochemistry.22-00095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Affiliation(s)
- Narimasa KOIZUMI
- Department of Applied Chemistry, Faculty of Engineering, Shibaura Institute of Technology
| | - Ryusei NISHIYAMA
- Department of Applied Chemistry, Faculty of Engineering, Shibaura Institute of Technology
| | - Takashi MASADOME
- Department of Applied Chemistry, Faculty of Engineering, Shibaura Institute of Technology
| |
Collapse
|
2
|
Wang N, Shi J, Liu Y, sun W, Su X. Constructing bifunctional metal–organic framework based nanozymes with fluorescence and oxidase activity for the dual-channel detection of butyrylcholinesterase. Anal Chim Acta 2022; 1205:339717. [DOI: 10.1016/j.aca.2022.339717] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 02/24/2022] [Accepted: 03/09/2022] [Indexed: 12/28/2022]
|
3
|
Qu Z, Yu T, Liu Y, Bi L. Determination of butyrylcholinesterase activity based on thiamine luminescence modulated by MnO 2 nanosheets. Talanta 2021; 224:121831. [PMID: 33379049 DOI: 10.1016/j.talanta.2020.121831] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 10/15/2020] [Accepted: 10/28/2020] [Indexed: 10/23/2022]
Abstract
In this paper, a novel strategy for biosensing butyrylcholinesterase (BChE) activity is developed based on manganese dioxide (MnO2) nanosheets to modulate the photoluminescence of thiamine (TH). The oxidase-like activity of MnO2 nanosheets enables them to catalyze the oxidation of non-fluorescent substrate TH to generate strong fluorescent thiochrome (TC). When the target BChE is introduced to form thiocholine in the presence of S-butyrylthiocholine iodide (BTCh), MnO2 nanosheets are reduced by thiocholine to Mn2+, resulting in the loss of their oxidase-like activity and the reduction of TC fluorescence. Based on this, a BChE activity fluorescence biosensor is constructed utilizing the luminescence behavior variation of TH and the oxidase-like activity of MnO2 nanosheets. The fluorescence biosensor shows a sensitive response to BChE, and the detection limit reaches 0.036 U L-1. In addition, the feasibility of the biosensor in real samples analysis is studied with satisfactory results.
Collapse
Affiliation(s)
- Zhengyi Qu
- College of Chemistry, Jilin University, Changchun, 130012, PR China
| | - Tian Yu
- College of Electrical and Electronic Engineering, Changchun University of Technology, Changchun, 130012, PR China
| | - Yuzhong Liu
- Jilin University First Hospital, Changchun, 130021, PR China
| | - Lihua Bi
- College of Chemistry, Jilin University, Changchun, 130012, PR China.
| |
Collapse
|
4
|
Potentiometric Carbon Quantum Dots-Based Screen-Printed Arrays for Nano-Tracing Gemifloxacin as a Model Fluoroquinolone Implicated in Antimicrobial Resistance. CHEMOSENSORS 2020. [DOI: 10.3390/chemosensors9010008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Antimicrobial resistance (AMR) is a neglected issue that poses a serious global threat to public health, causing long-term negative consequences at both humanitarian and economic levels. Herein, we report an unprecedented economic fabrication method of seven potentiometric screen-printed sensors for the ultra-trace determination of gemifloxacin (GEMI) as a model of the fluoroquinolones antibiotics deeply involved in the growing AMR problem. Sensors were constructed by depositing homemade carbon ink on a recycled X-ray sheet, patterned using stencils printed with an office printer in simple, cost-effective steps requiring no sophisticated equipment. Four sensors were modified using carbon quantum dots (CQDs) synthesized from dextrose through a single-step method. Sensors exhibited a linear response in the concentration ranges 10−5–10−2 M (sensors 1, 3 and 4), 10−6–10−3 M (sensor 2) and 10−6–10−2 M (sensors 5, 6 and 7). LOD allowed tracing of the target drug at a nano-molar level down to 210 nM. GEMI was successfully determined in pharmaceutical formulations and different water samples without any pretreatment steps with satisfactory recovery (96.93–105.28% with SD values < 3). All sensors revealed a long lifetime of up to several months and are considered promising tools for monitoring water quality and efficiency of water treatment measures.
Collapse
|
5
|
Guo L, Zhang YJ, Yu YL, Wang JH. In Situ Generation of Prussian Blue by MIL-53 (Fe) for Point-of-Care Testing of Butyrylcholinesterase Activity Using a Portable High-Throughput Photothermal Device. Anal Chem 2020; 92:14806-14813. [PMID: 33058681 DOI: 10.1021/acs.analchem.0c03575] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Butyrylcholinesterase (BuChE), the primary source of serum cholinesterase activity, is an indispensable biochemical marker for clinical diagnosis of liver function and organophosphorus poisoning. The requirement for bulky and expensive instruments represents a huge hindrance for point-of-care testing (POCT) of BuChE, especially in resource-limited settings. Herein, an easy-operated, economic, and portable photothermal (PT) biosensing platform for high-throughput BuChE detection was rationally designed. BuChE could "light up" the PT signal through in situ generation of Prussian blue (PB) by MIL-53 (Fe), which allowed us to translate biological signals into temperature signals. Such temperature change signals could be monitored at high throughput (six samples for a single measurement) by a miniature self-made integrated PT device via combining separable 96-well plates, a three-dimensional (3D) printed sample bracket, 808 nm lasers, and thermometers, satisfying the requirement for rapid on-site detection in a large batch with low cost. In addition, the large specific surface area, 3D network structure, and high porosity of MIL-53 (Fe) offered a beneficial platform for its reaction with enzymatic hydrolysate, resulting in high sensing sensitivity and low detection limit (0.3 U L-1), which was at least 20 000 times lower than the normal human serum BuChE activity. This facile, affordable, and broad applicability PT sensing platform provides a beneficial reference for the rational design of other disease diagnostic approaches suitable for POCT.
Collapse
Affiliation(s)
- Lan Guo
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Ya-Jie Zhang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Yong-Liang Yu
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Jian-Hua Wang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| |
Collapse
|
6
|
Yang Y, Liu H, Chen Z, Wu T, Jiang Z, Tong L, Tang B. A Simple 3D-Printed Enzyme Reactor Paper Spray Mass Spectrometry Platform for Detecting BuChE Activity in Human Serum. Anal Chem 2019; 91:12874-12881. [DOI: 10.1021/acs.analchem.9b02728] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Yanmei Yang
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Shandong Normal University, Jinan 250014, People’s Republic of China
| | - Huimin Liu
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Shandong Normal University, Jinan 250014, People’s Republic of China
| | - Zhenzhen Chen
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Shandong Normal University, Jinan 250014, People’s Republic of China
| | - Tianhong Wu
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Shandong Normal University, Jinan 250014, People’s Republic of China
| | - Zhongyao Jiang
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Shandong Normal University, Jinan 250014, People’s Republic of China
| | - Lili Tong
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Shandong Normal University, Jinan 250014, People’s Republic of China
| | - Bo Tang
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Shandong Normal University, Jinan 250014, People’s Republic of China
| |
Collapse
|
7
|
Pundir C, Malik A, Preety. Bio-sensing of organophosphorus pesticides: A review. Biosens Bioelectron 2019; 140:111348. [DOI: 10.1016/j.bios.2019.111348] [Citation(s) in RCA: 113] [Impact Index Per Article: 22.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Accepted: 05/22/2019] [Indexed: 01/09/2023]
|
8
|
Makarova NM, Kulapina EG. Planar sensors for determination of polyoxyethylated compounds. RUSS J ELECTROCHEM+ 2018. [DOI: 10.1134/s1023193517110088] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
9
|
Chen G, Feng H, Jiang X, Xu J, Pan S, Qian Z. Redox-Controlled Fluorescent Nanoswitch Based on Reversible Disulfide and Its Application in Butyrylcholinesterase Activity Assay. Anal Chem 2018; 90:1643-1651. [PMID: 29298486 DOI: 10.1021/acs.analchem.7b02976] [Citation(s) in RCA: 51] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Butyrylcholinesterase (BChE) mainly contributing to plasma cholinesterase activity is an important indicator for routinely diagnosing liver function and organophosphorus poisoning in clinical diagnosis, but its current assays are scarce and frequently suffer from some significant interference and instability. Herein, we report a redox-controlled fluorescence nanoswtich based on reversible disulfide bonds, and further develop a fluorometric assay of BChE via thiol-triggered disaggregation-induced emission. Thiol-functionalized carbon quantum dots (thiol-CQDs) with intense fluorescence is found to be responsive to hydrogen peroxide, and their redox reaction transforms thiol-CQDs to nonfluorescent thiol-CQD assembly. The thiols inverse this process by a thiol-exchange reaction to turn on the fluorescence. The fluorescence can be reversibly switched by the formation and breaking of disulfide bonds caused by external redox stimuli. The specific thiol-triggered disaggregation-induced emission enables us to assay BChE activity in a fluorescence turn-on and real-time way using butyrylthiocholine iodide as the substrate. As-established BChE assay achieves sufficient sensitivity for practical determination in human serum, and is capable of avoiding the interference from micromolar glutathione and discriminatively quantifying BChE from its sister enzyme acetylcholinesterase. The first design of reversible redox-controlled nanosiwtch based on disulfide expands the application of disulfide chemistry in sensing and clinical diagnostics, and this novel BChE assay enriches the detection methods for cholinesterase activity.
Collapse
Affiliation(s)
- Guilin Chen
- College of Chemistry and Life Science, Zhejiang Normal University , Jinhua 321004, People's Republic of China
| | - Hui Feng
- College of Chemistry and Life Science, Zhejiang Normal University , Jinhua 321004, People's Republic of China
| | - Xiaogan Jiang
- College of Chemistry and Life Science, Zhejiang Normal University , Jinhua 321004, People's Republic of China
| | - Jing Xu
- College of Chemistry and Life Science, Zhejiang Normal University , Jinhua 321004, People's Republic of China
| | - Saifei Pan
- College of Chemistry and Life Science, Zhejiang Normal University , Jinhua 321004, People's Republic of China
| | - Zhaosheng Qian
- College of Chemistry and Life Science, Zhejiang Normal University , Jinhua 321004, People's Republic of China
| |
Collapse
|
10
|
Affiliation(s)
- Šárka Štěpánková
- Faculty of Chemical Technology, Department of Biological and Biochemical Sciences, University of Pardubice, Pardubice, Czech Republic
| | - Katarína Vorčáková
- Faculty of Chemical Technology, Department of Biological and Biochemical Sciences, University of Pardubice, Pardubice, Czech Republic
| |
Collapse
|
11
|
Makarova NM, Kulapina EG. Planar potentiometric sensors based on carbon materials for determination of sodium dodecyl sulfate. RUSS J ELECTROCHEM+ 2015. [DOI: 10.1134/s1023193515070034] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
12
|
Double-imprinted potentiometric sensors based on ligand exchange for the determination of dimethoate. KOREAN J CHEM ENG 2015. [DOI: 10.1007/s11814-014-0386-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
13
|
Pohanka M. Determination of acetylcholinesterase and butyrylcholinesterase activity without dilution of biological samples. CHEMICAL PAPERS 2015. [DOI: 10.1515/chempap-2015-0117] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
AbstractTwo cholinesterases: acetylcholinesterase (AChE) and butyrylcholinesterase (BChE), are known. The enzymes are important in the body and alteration of their activity has significant use in the diagnosis of poisoning, liver function, etc. Currently available methods for the determination of cholinesterases have some major drawbacks including various interferences and the inability to be used for decreasing the enzyme activity in the presence of reversible inhibitors due to sample dilution; hence, a method for dilution free assay of cholinesterases is desired. Here, microplates were modified with indoxylacetate (100 μL of 10 mmol L
Collapse
|
14
|
Biosensors containing acetylcholinesterase and butyrylcholinesterase as recognition tools for detection of various compounds. CHEMICAL PAPERS 2015. [DOI: 10.2478/s11696-014-0542-x] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
AbstractAcetylcholinesterase (AChE) and butyrylcholinesterase (BChE) are enzymes expressed in the human body under physiological conditions. AChE is an important part of the cholinergic nerves where it hydrolyses neurotransmitter acetylcholine. Both cholinesterases are sensitive to inhibitors acting as neurotoxic compounds. In analytical applications, the enzymes can serve as a biorecognition element in biosensors as well as simple disposable sensors (dipsticks) and be used for assaying the neurotoxic compounds. In the present review, the mechanism of AChE and BChE inhibition by disparate compounds is explained and methods for assaying the enzymes activity are shown. Optical, electrochemical, and piezoelectric biosensors are described. Attention is also given to the application of sol-gel techniques and quantum dots in the biosensors’ construction. Examples of the biosensors are provided and the pros and cons are discussed.
Collapse
|
15
|
Khaled E, Kamel MS, Hassan H, Abdel-Gawad H, Aboul-Enein HY. Performance of a portable biosensor for the analysis of ethion residues. Talanta 2014; 119:467-72. [DOI: 10.1016/j.talanta.2013.11.001] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2013] [Revised: 10/31/2013] [Accepted: 11/01/2013] [Indexed: 11/30/2022]
|
16
|
Pohanka M. Voltammetric assay of butyrylcholinesterase in plasma samples and its comparison to the standard spectrophotometric test. Talanta 2014; 119:412-6. [DOI: 10.1016/j.talanta.2013.11.045] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2013] [Revised: 11/09/2013] [Accepted: 11/15/2013] [Indexed: 01/10/2023]
|
17
|
Özkütük EB, Diltemiz SE, Özalp E, Ersöz A, Say R. Silan based paraoxon memories onto QCM electrodes. J IND ENG CHEM 2013. [DOI: 10.1016/j.jiec.2013.02.021] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
18
|
|
19
|
Chen Z, Ren X, Meng X, Tan L, Chen D, Tang F. Quantum dots-based fluorescent probes for turn-on and turn-off sensing of butyrylcholinesterase. Biosens Bioelectron 2013; 44:204-9. [DOI: 10.1016/j.bios.2013.01.034] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2012] [Revised: 01/10/2013] [Accepted: 01/18/2013] [Indexed: 11/26/2022]
|
20
|
Affiliation(s)
- Danielle W. Kimmel
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, VU Station B 351822, Nashville, TN 37235-1822
| | - Gabriel LeBlanc
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, VU Station B 351822, Nashville, TN 37235-1822
| | - Mika E. Meschievitz
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, VU Station B 351822, Nashville, TN 37235-1822
| | - David E. Cliffel
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, VU Station B 351822, Nashville, TN 37235-1822
| |
Collapse
|