1
|
Tariq A, Bilal S, Naz I, Nawaz MH, Andreescu S, Jubeen F, Arif A, Hayat A. A multifunctional N-GO/PtCo nanocomposite bridged carbon fiber interface for the electrochemical aptasensing of CA15-3 oncomarker. Anal Biochem 2024; 695:115640. [PMID: 39142532 DOI: 10.1016/j.ab.2024.115640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2024] [Revised: 08/03/2024] [Accepted: 08/12/2024] [Indexed: 08/16/2024]
Abstract
The development of integrated analytical devices is crucial for advancing next-generation point-of-care platforms. Herein, we describe a facile synthesis of a strongly catalytic and durable Nitrogen-doped graphene oxide decorated platinum cobalt (NGO-PtCo) nanocomposite that is conjugated with target-specific DNA aptamer (i-e. MUC1) and grown on carbon fiber. Benefitting from the combined features of the high electrochemical surface area of N-doped GO, high capacitance and stabilization by Co, and high kinetic performance by Pt, a robust, multifunctional, and flexible nanotransducer surface was created. The designed platform was applied for the specific detection of a blood-based oncomarker, CA15-3. The electrochemical characterization proved that nanosurface provides a highly conductive and proficient immobilization support with a strong bio-affinity towards MUC1 aptamer. The specific interaction between CA15-3 and the aptamer alters the surface properties of the aptasensor and the electroactive signal probe generated a remarkable increase in signal intensity. The sensor exhibited a wide dynamic range of 5.0 × 10-2 -200 U mL-1, a low limit of detection (LOD) of 4.1 × 10-2 U mL-1, and good reproducibility. The analysis of spiked serum samples revealed outstanding recoveries of up to 100.03 %, by the proposed aptasensor. The aptasensor design opens new revelations in the reliable detection of tumor biomarkers for timely cancer diagnosis.
Collapse
Affiliation(s)
- Aqsa Tariq
- Interdisciplinary Research Center in Biomedical Materials (IRCBM), COMSATS University, Islamabad, Lahore Campus, Lahore, 54000, Pakistan; Department of Basic and Applied Chemistry, Faculty of Science and Technology, University of Central Punjab, Lahore, 54000, Pakistan
| | - Sehrish Bilal
- Department of Biochemistry, Gulab Devi Educational Complex, Gulab Devi Hospital, Lahore, 05307, Pakistan.
| | - Iram Naz
- Interdisciplinary Research Center in Biomedical Materials (IRCBM), COMSATS University, Islamabad, Lahore Campus, Lahore, 54000, Pakistan; Department of Chemistry, Government College Women University, Faisalabad, 38000, Pakistan
| | - Mian Hasnain Nawaz
- Interdisciplinary Research Center in Biomedical Materials (IRCBM), COMSATS University, Islamabad, Lahore Campus, Lahore, 54000, Pakistan
| | - Silvana Andreescu
- Department of Chemistry and Biomolecular Science, Clarkson University, 8 Clarkson Avenue, Potsdam, NY, 13699-5810, USA; Department of Environmental Health Sciences, Robert Stempel College of Public Health, Florida International University (FIU), 11200 SW 8th Street, AHC-5, Miami, FL, 33199, USA
| | - Farhat Jubeen
- Department of Chemistry, Government College Women University, Faisalabad, 38000, Pakistan
| | - Amina Arif
- Department of Basic and Applied Chemistry, Faculty of Science and Technology, University of Central Punjab, Lahore, 54000, Pakistan
| | - Akhtar Hayat
- Interdisciplinary Research Center in Biomedical Materials (IRCBM), COMSATS University, Islamabad, Lahore Campus, Lahore, 54000, Pakistan.
| |
Collapse
|
2
|
Hou J, Xia B, Niu K, Wang J, Li J, Wang N. Ultrasensitive optical fiber SPR sensor enhanced by Au-NPs-film modified with functionalized CQDs for label-free detecting cobalt (II) ion. Anal Chim Acta 2024; 1320:343030. [PMID: 39142794 DOI: 10.1016/j.aca.2024.343030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 07/23/2024] [Accepted: 07/24/2024] [Indexed: 08/16/2024]
Abstract
BACKGROUND Cobalt, an essential trace element, is vital for maintaining human nervous system function, aiding in DNA synthesis, and contributing to red blood cell production. It is helpful for disease diagnosis and treatment plan evaluation by precisely monitoring its concentration changes in the human body. Despite extensive efforts made, due to its ultra-low concentration, the current limit of detection (LOD) as reported is still inadequate and cannot be satisfied with the precise clinical applications. Therefore, it is crucial to develop novel label-free sensors with high sensitivity and excellent selectivity for detecting trace amounts of Co2+. RESULTS Here, an ultrasensitive optical fiber SPR sensor was designed and fabricated for label-free detection of Co2+ with ultra-low concentration. It is achieved by modifying the carboxyl-functionalized CQDs on the AuNPs/Au film-coated hetero-core fiber, which can specifically capture the Co2+, leading to changes in the fiber's surface refractive index (RI) and subsequent SPR wavelength shifts in the transmission spectrum. Both the Au film and AuNPs on the fiber are modified with CQDs, leveraging their large surface area to enhance the number of active sites and probes. The sensor exhibits an ultra-high sensitivity of approximately 6.67 × 1019 nm/M, and the LOD is obtained as low as 5.36 × 10-20 M which is several orders of magnitude lower compared to other conventional methods. It is also experimentally demonstrated that the sensor possesses excellent specificity, stability, and repeatability, which may be adapted for detecting real clinical samples. SIGNIFICANCE The CQDs-functionalized optical fiber SPR sensor exhibits substantial potential for precisely detecting Co2+ of trace amounts, which is especially vital for scarce clinical samples. Additionally, the sensing platform with sample sensor fabrication and measurement configuration introduces a novel, highly sensitive approach to biochemical analysis, particularly adapting for applications involving the detection of trace targets, which could also be employed to detect various biochemical targets by facile modification of CQDs with specific groups or biomolecules.
Collapse
Affiliation(s)
- Jianguo Hou
- National Engineering Research Center of Fiber Optic Sensing Technology and Networks, Wuhan University of Technology, Wuhan, 430070, China
| | - Binyun Xia
- National Engineering Research Center of Fiber Optic Sensing Technology and Networks, Wuhan University of Technology, Wuhan, 430070, China
| | - Kunpeng Niu
- National Engineering Research Center of Fiber Optic Sensing Technology and Networks, Wuhan University of Technology, Wuhan, 430070, China
| | - Jiale Wang
- National Engineering Research Center of Fiber Optic Sensing Technology and Networks, Wuhan University of Technology, Wuhan, 430070, China
| | - Jinhua Li
- Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, Collaborative Innovation Center for Advanced Organic Chemical Materials Co-Constructed by the Province and Ministry, School of Materials Science and Engineering, Hubei University, Ministry of Education, Wuhan, 430062, China
| | - Ning Wang
- National Engineering Research Center of Fiber Optic Sensing Technology and Networks, Wuhan University of Technology, Wuhan, 430070, China.
| |
Collapse
|
3
|
Tiwari MS, Kadu AK. Thiol-based chemically modified carbon screen-printed electrode for simultaneous quantification of trace level Pb(II) and Cd(II). ANAL SCI 2024; 40:1449-1457. [PMID: 38740715 PMCID: PMC11269355 DOI: 10.1007/s44211-024-00581-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Accepted: 04/15/2024] [Indexed: 05/16/2024]
Abstract
Present work reports, the development of a novel electrochemical sensor based on a diazonium-coupling reaction and covalent attachment of the -NH2 group of cysteamine (Cyst) on screen-printed carbon electrode (SPCE), for simultaneous determination of Pb(II) and Cd(II). Initially, the in-situ generated 4-carboxyphenyl (4-CP) diazonium salt was electro-grafted to generate 4-CP/SPCE, followed by covalent bonding of terminal carboxylic group of 4-CP with -NH2 group of Cyst to give Cyst/4-CP/SPCE. The modified electrode showed an enhanced selectivity and sensitivity toward the quantification of Pb(II) and Cd(II) using square wave anodic stripping voltammetry (SWASV) without mutual interference. Under optimal experimental conditions, the newly designed sensor showed a wide linear range of 0.01 µM to 0.7 µM. The limit of detection (LOD) obtained was 0.882 nM (0.09 ppb) and 0.65 nM (0.134 ppb) for Cd(II) and Pb(II), respectively. The modified SPCE exhibited good stability, selectivity, and reproducibility. Furthermore, the sensor was successfully applied for the determination of Pb(II) and Cd(II) ions in water samples which illustrated excellent recoveries in different spiked samples and the results were in line with the standard ICP-AES analysis.
Collapse
Affiliation(s)
- Mritunjay S Tiwari
- University Department of Chemistry, University of Mumbai, Vidyanagari, Santacruz (East), Mumbai, 400 098, India
| | - Arun K Kadu
- University Department of Chemistry, University of Mumbai, Vidyanagari, Santacruz (East), Mumbai, 400 098, India.
| |
Collapse
|
4
|
Ji Y, Wang R, Zhao H. Toward Sensitive and Reliable Immunoassays of Marine Biotoxins: From Rational Design to Food Analysis. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2024; 72:16076-16094. [PMID: 39010820 DOI: 10.1021/acs.jafc.4c01865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/17/2024]
Abstract
Marine biotoxins are metabolites produced by algae that can accumulate in shellfish or fish and enter organisms through the food chain, posing a serious threat to biological health. Therefore, accurate and rapid detection is an urgent requirement for food safety. Although various detection methods, including the mouse bioassay, liquid chromatography-mass spectrometry, and cell detection methods, and protein phosphatase inhibition assays have been developed in the past decades, the current detection methods cannot fully meet these demands. Among these methods, the outstanding immunoassay virtues of high sensitivity, reliability, and low cost are highly advantageous for marine biotoxin detection in complex samples. In this work, we review the recent 5-year progress in marine biotoxin immunodetection technologies such as optical immunoassays, electrochemical immunoassays, and piezoelectric immunoassays. With the assistance of immunoassays, the detection of food-related marine biotoxins can be implemented for ensuring public health and preventing food poisoning. In addition, the immunodetection technique platforms including lateral flow chips and microfluidic chips are also discussed. We carefully investigate the advantages and disadvantages for each immunoassay, which are compared to demonstrate the guidance for selecting appropriate immunoassays and platforms for the detection of marine biotoxins. It is expected that this review will provide insights for the further development of immunoassays and promote the rapid progress and successful translation of advanced immunoassays with food safety detection.
Collapse
Affiliation(s)
- Yuxiang Ji
- State Key Laboratory of Marine Resources Utilization in South China Sea and Center for Eco-Environment Restoration of Hainan Province, Hainan University, Haikou 570228, China
- NHC Key Laboratory of Tropical Disease Control, School of Tropical Medicine, Hainan Medical University, Haikou, Hainan 571199, China
| | - Rui Wang
- Key Laboratory of Hainan Trauma and Disaster Rescue, The First Affiliated Hospital of Hainan Medical University, Engineering Research Center for Hainan Bio-Smart Materials and Bio-Medical Devices, College of Emergency and Trauma, Hainan Medical University, Haikou 571199, China
| | - Hongwei Zhao
- State Key Laboratory of Marine Resources Utilization in South China Sea and Center for Eco-Environment Restoration of Hainan Province, Hainan University, Haikou 570228, China
| |
Collapse
|
5
|
Li S, Gong L, Wu X, Liu X, Bai N, Guo Y, Liu X, Zhang H, Fu H, Shou Q. Load-bearing columns inspired fabrication of ductile and mechanically enhanced BSA hydrogels. Int J Biol Macromol 2024; 261:129910. [PMID: 38309395 DOI: 10.1016/j.ijbiomac.2024.129910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 01/21/2024] [Accepted: 01/31/2024] [Indexed: 02/05/2024]
Abstract
Currently, protein-based hydrogels are widely applied in soft materials, tissue engineering and implantable scaffolds owing to their excellent biocompatibility, and degradability. However, most protein-based hydrogels are soft brittle. In this study, a ductile and mechanically enhanced bovine serum albumin (BSA) hydrogel is fabricated by soaking the a 1-(3-dimethylaminopropyl)-3ethylcarbodiimide hydrochloride/N-hydroxysuccinimide (EDC/NHS) induced BSA hydrogel in (NH4)2SO4 solution. An EDC/NHS coupling reaction induce protein coupling reactions that cause the BSA skeleton to resemble architectural load-bearing walls, protecting the integrity of the hydrogel and preventing collapse. The effects of the BSA and (NH4)2SO4 concentrations on the hydrogel mechanics are evaluated, and the possible strengthening mechanism is discussed. Besides, the highly kosmotropic ions greatly enhance the hydrophobic interaction within BSA gels and dehydration effect and their mechanical properties were significantly enhanced. The various mechanical properties of hydrogels can be regulated over a large window by soaking hydrogels into various ions. And most of them can be washed away, maintaining high biocompatibility of the protein. Importantly, the protein hydrogels prepared by this strategy could also be modified as strain sensors. In a word, this work demonstrates a new, universal method to provide multi-functional, biocompatible, strength enhanced and regulable mechanical pure protein hydrogel, combining the Hofmeister effect with -NH2/-COOH association groups.
Collapse
Affiliation(s)
- Shengyu Li
- The Second Affiliated Hospital of Zhejiang Chinese Medical University, Second Clinical Medical School of Zhejiang Chinese Medical University, Hangzhou 310000, PR China.
| | - Lihong Gong
- The Second Affiliated Hospital of Zhejiang Chinese Medical University, Second Clinical Medical School of Zhejiang Chinese Medical University, Hangzhou 310000, PR China; Third Clinical Medical School of Zhejiang Chinese Medical University, Hangzhou 310000, PR China
| | - Xijin Wu
- The Second Affiliated Hospital of Zhejiang Chinese Medical University, Second Clinical Medical School of Zhejiang Chinese Medical University, Hangzhou 310000, PR China
| | - Xianli Liu
- The Second Affiliated Hospital of Zhejiang Chinese Medical University, Second Clinical Medical School of Zhejiang Chinese Medical University, Hangzhou 310000, PR China
| | - Ningning Bai
- The Second Affiliated Hospital of Zhejiang Chinese Medical University, Second Clinical Medical School of Zhejiang Chinese Medical University, Hangzhou 310000, PR China
| | - Yingxue Guo
- The Second Affiliated Hospital of Zhejiang Chinese Medical University, Second Clinical Medical School of Zhejiang Chinese Medical University, Hangzhou 310000, PR China
| | - Xia Liu
- The Second Affiliated Hospital of Zhejiang Chinese Medical University, Second Clinical Medical School of Zhejiang Chinese Medical University, Hangzhou 310000, PR China
| | - Hong Zhang
- The Second Affiliated Hospital of Zhejiang Chinese Medical University, Second Clinical Medical School of Zhejiang Chinese Medical University, Hangzhou 310000, PR China
| | - Huiying Fu
- The Second Affiliated Hospital of Zhejiang Chinese Medical University, Second Clinical Medical School of Zhejiang Chinese Medical University, Hangzhou 310000, PR China.
| | - Qiyang Shou
- The Second Affiliated Hospital of Zhejiang Chinese Medical University, Second Clinical Medical School of Zhejiang Chinese Medical University, Hangzhou 310000, PR China; Jinghua academy of Zhejiang Chinese Medicine University, Jinghua 321015, PR China.
| |
Collapse
|
6
|
Ndhlala AR, Kavaz Yüksel A, Çelebi N, Doğan HÖ. A General Review of Methodologies Used in the Determination of Cholesterol (C 27H 46O) Levels in Foods. Foods 2023; 12:4424. [PMID: 38137228 PMCID: PMC10742886 DOI: 10.3390/foods12244424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 12/05/2023] [Accepted: 12/08/2023] [Indexed: 12/24/2023] Open
Abstract
Cholesterol (C27H46O) is a lipid-derived substance found in lipoproteins and cell membranes. It is also one of the main sources for the production of bile acids, vitamin D, and steroid hormones. Today, foods are evaluated by consumers not only according to their taste and nutritional content but also according to their effects on consumer health. For example, many consumers choose foods according to their cholesterol level. The cholesterol in the food can directly affect the blood cholesterol level when consumed, which can lead to cardiovascular diseases. High levels of cholesterol can lead to diet-related human diseases such as cardiac arrest, paralysis, type II diabetes, and cerebral hemorrhage. In societies with high living standards, interest in and consumption of foods that lower or have low cholesterol levels have increased recently. Accordingly, efforts to increase the variety of foods with reduced cholesterol levels are on the rise. This has indirectly led to the accurate measurement of cholesterol levels in blood and food being of great importance. Classical chemical, enzymatic, colorimetric, polarographic, chromatographic, and spectrophotometric methods; enzymatic, nonenzymatic, and electrochemical sensors; and biosensors are used for the determination of cholesterol in foods. The purpose of this review is to reveal and explore current and future trends in cholesterol detection methods in foods. This review will summarize the most appropriate and standard methods for measuring cholesterol in biological components and foods.
Collapse
Affiliation(s)
- Ashwell R. Ndhlala
- Green Biotechnologies Research Centre, School of Agricultural and Environmental Sciences, University of Limpopo, Private Bag X1106, Sovenga 0727, South Africa;
| | - Arzu Kavaz Yüksel
- Department of Food Technology, Technical Sciences Vocational School, Atatürk University, Erzurum 25030, Turkey
| | - Neslihan Çelebi
- Department of Chemical Technology, Vocational School of Technical Sciences, Ataturk University, Erzurum 25030, Turkey; (N.Ç.); (H.Ö.D.)
| | - Hülya Öztürk Doğan
- Department of Chemical Technology, Vocational School of Technical Sciences, Ataturk University, Erzurum 25030, Turkey; (N.Ç.); (H.Ö.D.)
| |
Collapse
|
7
|
Ji Y, Cai G, Liang C, Gao Z, Lin W, Ming Z, Feng S, Zhao H. A microfluidic immunosensor based on magnetic separation for rapid detection of okadaic acid in marine shellfish. Anal Chim Acta 2023; 1239:340737. [PMID: 36628732 DOI: 10.1016/j.aca.2022.340737] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Revised: 12/18/2022] [Accepted: 12/20/2022] [Indexed: 12/24/2022]
Abstract
Okadaic acid (OA) is a marine biotoxin that accumulates in seafood and can cause diarrheic shellfish poisoning if consumed. Accordingly, many countries have established regulatory limits for the content of OA in shellfish. At present, methods used for the detection of marine toxins are time-consuming and labor-intensive. In order to realize rapid, simple, and accurate detection of OA, we developed a novel microfluidic immunosensor based on magnetic beads modified with a highly specific and sensitive monoclonal antibody (mAb) against OA that is used in conjunction with smartphone imaging to realize the rapid detection of OA in shellfish. The method achieves on-site detection results within 1 h with an IC50 value of 3.30 ng/mL for OA and a limit of detection (LOD) of 0.49 ng/mL. In addition, the analysis of real samples showed that the recoveries for spiked shellfish samples ranged from 84.91% to 95.18%, and the results were confirmed by indirect competitive enzyme-linked immunosorbent assay (icELISA), indicating that the method has good accuracy and precision. Furthermore, the results are reported in a specially designed smartphone app. The microfluidic immunosensor has the advantages of simple operation, rapid detection, and high sensitivity, providing a reliable technical solution for detecting OA residues in shellfish.
Collapse
Affiliation(s)
- Yuxiang Ji
- State Key Laboratory of Marine Resources Utilization in South China Sea and Center for Eco-Environment Restoration of Hainan Province, Hainan University, Haikou, 570228, China; Key Laboratory of Tropical Translational Medicine of Ministry of Education, NHC Key Laboratory of Tropical Disease Control, School of Tropical Medicine, Hainan Medical University, Haikou, 571199, China
| | - Gaozhe Cai
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Cheng Liang
- State Key Laboratory of Marine Resources Utilization in South China Sea and Center for Eco-Environment Restoration of Hainan Province, Hainan University, Haikou, 570228, China
| | - Zehang Gao
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China; Department of Clinical Laboratory, Third Affiliated Hospital of Guangzhou Medical University, Guangdong, 510150, China
| | - Weimin Lin
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China; Key Laboratory of OptoElectronic Science and Technology for Medicine of Ministry of Education, Fujian Normal University, Fuzhou, 350007, China
| | - Zizhen Ming
- Shanghai Institute of Immunology, Department of Immunology and Microbiology, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
| | - Shilun Feng
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China.
| | - Hongwei Zhao
- State Key Laboratory of Marine Resources Utilization in South China Sea and Center for Eco-Environment Restoration of Hainan Province, Hainan University, Haikou, 570228, China.
| |
Collapse
|
8
|
de Souza Freire L, Ruzo CM, Salgado BB, Gandarilla AMD, Romaguera-Barcelay Y, Tavares APM, Sales MGF, Cordeiro I, Lalwani JDB, Matos R, Fonseca Filho H, Astolfi-Filho S, Ţălu Ş, Lalwani P, Brito WR. An Electrochemical Immunosensor Based on Carboxylated Graphene/SPCE for IgG-SARS-CoV-2 Nucleocapsid Determination. BIOSENSORS 2022; 12:bios12121161. [PMID: 36551128 PMCID: PMC9775996 DOI: 10.3390/bios12121161] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 12/01/2022] [Accepted: 12/04/2022] [Indexed: 05/14/2023]
Abstract
The COVID-19 pandemic has emphasized the importance and urgent need for rapid and accurate diagnostic tests for detecting and screening this infection. Our proposal was to develop a biosensor based on an ELISA immunoassay for monitoring antibodies against SARS-CoV-2 in human serum samples. The nucleocapsid protein (N protein) from SARS-CoV-2 was employed as a specific receptor for the detection of SARS-CoV-2 nucleocapsid immunoglobulin G. N protein was immobilized on the surface of a screen-printed carbon electrode (SPCE) modified with carboxylated graphene (CG). The percentage of IgG-SARS-CoV-2 nucleocapsid present was quantified using a secondary antibody labeled with horseradish peroxidase (HRP) (anti-IgG-HRP) catalyzed using 3,3',5,5'-tetramethylbenzidine (TMB) mediator by chronoamperometry. A linear response was obtained in the range of 1:1000-1:200 v/v in phosphate buffer solution (PBS), and the detection limit calculated was 1:4947 v/v. The chronoamperometric method showed electrical signals directly proportional to antibody concentrations due to antigen-antibody (Ag-Ab) specific and stable binding reaction.
Collapse
Affiliation(s)
- Luciana de Souza Freire
- Department of Chemistry, Institute of Exact Sciences, Federal University of Amazonas, Manaus 69067-005, AM, Brazil
| | - Camila Macena Ruzo
- Department of Chemistry, Institute of Exact Sciences, Federal University of Amazonas, Manaus 69067-005, AM, Brazil
| | | | - Ariamna María Dip Gandarilla
- Department of Chemistry, Institute of Exact Sciences, Federal University of Amazonas, Manaus 69067-005, AM, Brazil
| | - Yonny Romaguera-Barcelay
- Department of Chemistry, Institute of Exact Sciences, Federal University of Amazonas, Manaus 69067-005, AM, Brazil
- BioMark@UC, Department of Chemical Engineering, Faculty of Sciences and Technology, University of Coimbra, 3030-790 Coimbra, Portugal
| | - Ana P. M. Tavares
- BioMark@UC, Department of Chemical Engineering, Faculty of Sciences and Technology, University of Coimbra, 3030-790 Coimbra, Portugal
| | - Maria Goreti Ferreira Sales
- BioMark@UC, Department of Chemical Engineering, Faculty of Sciences and Technology, University of Coimbra, 3030-790 Coimbra, Portugal
| | - Isabelle Cordeiro
- Department of Physiological Sciences, Institute of Biological Sciences, Federal University of Amazonas, Manaus 69067-005, AM, Brazil
| | | | - Robert Matos
- Amazonian Materials Group, Federal University of Amapá (UNIFAP), Macapá 49100-000, AP, Brazil
| | - Henrique Fonseca Filho
- Laboratory of Nanomaterials Synthesis and Nanoscopy (LSNN), Federal University of Amazonas (UFAM), Manaus 69067-005, AM, Brazil
| | - Spartaco Astolfi-Filho
- Department of Chemistry, Institute of Exact Sciences, Federal University of Amazonas, Manaus 69067-005, AM, Brazil
- PPGBIOTEC, Federal University of Amazonas, Manaus 69067-005, AM, Brazil
| | - Ştefan Ţălu
- The Directorate of Research, Development and Innovation Management (DMCDI), The Technical University of Cluj-Napoca, Constantin Daicoviciu Street, No. 15, 400020 Cluj-Napoca, Romania
| | - Pritesh Lalwani
- Instituto Leônidas e Maria Deane (ILMD), Fiocruz Amazônia, Manaus 69067-005, AM, Brazil
| | - Walter Ricardo Brito
- Department of Chemistry, Institute of Exact Sciences, Federal University of Amazonas, Manaus 69067-005, AM, Brazil
- PPGBIOTEC, Federal University of Amazonas, Manaus 69067-005, AM, Brazil
- Correspondence: ; Tel.: +55-92981379920
| |
Collapse
|
9
|
Development of a Chemiluminescent Method in a Microfluidic Device for Ultrasensitive Determination of Okadaic Acid with Highly Efficient Aptamer-Based Isolation. SEPARATIONS 2022. [DOI: 10.3390/separations9110350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Rapid detection of okadaic acid (OA) in shellfish is crucial for practical application in food safety analysis. In order to establish a rapid, delicate detection scheme, an OA aptamer was utilized to quickly capture OA from the sample solution with polystyrene microspheres as solid phase carriers, and an inner-microchannel dam structure was designed to intercept the aptamer-functionalized microspheres to achieve the separation of OA for detection. Horseradish peroxidase (HRP) is utilized to catalyze the luminescence reaction of luminol-H2O2 solution. Through the direct competition for the aptamer between OA and OA-HRP, the rapid detection of OA can be achieved. The dynamic range of this detection method is 41.3–4.02 ng/mL, and the limit of detection (LOD) and lowest limit of quantitation (LOQ) are 12.4 pg/mL and 41.3 pg/mL, respectively. This miniaturized device enables rapid, ultrasensitive detection of OA, and demonstrates the merits of its field portability and low reagent consumption. The device can be deployed for on-site detection and analysis of marine biotoxins thereof.
Collapse
|
10
|
Kweon SY, Park JP, Park CY, Park TJ. Graphene Oxide-Mediated Fluorometric Aptasensor for Okadaic Acid Detection. BIOCHIP JOURNAL 2022. [DOI: 10.1007/s13206-022-00056-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
11
|
Bilal S, Sami AJ, Hayat A, Fayyaz Ur Rehman M. Assessment of pesticide induced inhibition of Apis mellifera (honeybee) acetylcholinesterase by means of N-doped carbon dots/BSA nanocomposite modified electrochemical biosensor. Bioelectrochemistry 2022; 144:107999. [PMID: 34801807 DOI: 10.1016/j.bioelechem.2021.107999] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Revised: 11/04/2021] [Accepted: 11/09/2021] [Indexed: 11/30/2022]
Abstract
This work describes the development and optimization of an electrochemical method to evaluate pesticide induced inhibition of honey bee (Apis mellifera) acetylcholinesterase (AChE) by means of acetylcholinesterase biosensor. The inhibition assay was based on the detection of changes in electrochemical activity of the enzyme caused by pesticide. As transducer, nitrogen doped carbon dots BSA (N-CD/BSA) nanocomposite electrodeposited on pencil graphite electrode was used to covalently immobilize AChE. The as-synthesized nanocomposite and fabricated electrodes were characterized for the structural, functional and electrochemical properties. Nanocomposite promoted the electron transfer reaction to catalyze the electro-oxidation of thiocholine and a large current response was obtained by cyclic voltammetry at 0.77 V, indicating successful immobilization of AChE. The sensitivity of Diazinon, an OP insecticide, for honeybee AChE was tested under optimal conditions and a linear response ranging 10-250 nM was obtained with a detection limit of 8.9 nM, and sensitivity 9 uA/nM/cm2. The method showed a good operational reproducibility and selectivity of biosensor. Further, the molecular docking provided additional support to the experimental data suggesting irreversible nature and contact toxicity of the pesticide for honey bee AChE. The developed biosensor has proved useful for the diazinon detection in wheat samples with 99% recovery rate.
Collapse
Affiliation(s)
- Sehrish Bilal
- School of Biochemistry and Biotechnology, University of the Punjab, Lahore 54000, Pakistan; Interdisciplinary Research Center in Biomedical Materials (IRCBM), COMSATS University, Islamabad, Lahore Campus, Lahore 54000, Pakistan.
| | - Amtul Jamil Sami
- School of Biochemistry and Biotechnology, University of the Punjab, Lahore 54000, Pakistan; Center for Biosensor Research and Development (CBRD), University of the Punjab, Lahore 54000, Pakistan.
| | - Akhtar Hayat
- Interdisciplinary Research Center in Biomedical Materials (IRCBM), COMSATS University, Islamabad, Lahore Campus, Lahore 54000, Pakistan.
| | | |
Collapse
|
12
|
Sainz R, Pozo MD, Vázquez L, Vilas-Varela M, Castro-Esteban J, Blanco E, Petit-Domínguez MD, Quintana C, Casero E. Lactate biosensing based on covalent immobilization of lactate oxidase onto chevron-like graphene nanoribbons via diazotization-coupling reaction. Anal Chim Acta 2022; 1208:339851. [DOI: 10.1016/j.aca.2022.339851] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 04/05/2022] [Accepted: 04/16/2022] [Indexed: 01/04/2023]
|
13
|
Zahra QUA, Fang X, Luo Z, Ullah S, Fatima S, Batool S, Qiu B, Shahzad F. Graphene Based Nanohybrid Aptasensors in Environmental Monitoring: Concepts, Design and Future Outlook. Crit Rev Anal Chem 2022; 53:1433-1454. [PMID: 35085047 DOI: 10.1080/10408347.2022.2025758] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023]
Abstract
In view of ever-increasing environmental pollution, there is an immediate requirement to promote cheap, multiplexed, sensitive and fast biosensing systems to monitor these pollutants or contaminants. Aptamers have shown numerous advantages in being used as molecular recognition elements in various biosensing devices. Graphene and graphene-based materials/nanohybrids combined with several detection methods exhibit great potential owing to their exceptional optical, electronic and physicochemical properties which can be employed extensively to monitor environmental contaminants. For environmental monitoring applications, aptamers have been successfully combined with graphene-based nanohybrids to produce a wide range of innovative methodologies. Aptamers are immobilized at the surface of graphene based nanohybrids via covalent and non-covalent strategies. This review highlights the design, working principle, recent developmental advances and applications of graphene based nanohybrid aptasensors (GNH-Apts) (since January 2014 to September 2021) with a special emphasis on two major signal-transduction methods, i.e., optical and electrochemical for the monitoring of pesticides, heavy metals, bacteria, antibiotics, and organic compounds from different environmental samples (e.g., water, soil and related). Lastly, the challenges confronted by scientists and the possible future outlook have also been addressed. It is expected that high-performance graphene-based nanohybrid aptasensors would find broad applications in the field of environmental monitoring.
Collapse
Affiliation(s)
- Qurat Ul Ain Zahra
- Biomedical Imaging Center, University of Science and Technology of China, Hefei, Anhui, China
- The Key Laboratory of Zhejiang Province for Aptamers and Theranostics, Institute of Basic Medicine and Cancer (IBMC), Chinese Academy of Sciences, Hangzhou, China
| | - Xiaona Fang
- The Key Laboratory of Zhejiang Province for Aptamers and Theranostics, Institute of Basic Medicine and Cancer (IBMC), Chinese Academy of Sciences, Hangzhou, China
- School of Nano-Tech and Nano-Bionics, University of Science and Technology of China, Hefei, China
- CAS Key Laboratory of Nano-Bio Interface, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou, China
| | - Zhaofeng Luo
- The Key Laboratory of Zhejiang Province for Aptamers and Theranostics, Institute of Basic Medicine and Cancer (IBMC), Chinese Academy of Sciences, Hangzhou, China
| | - Salim Ullah
- School of Nano-Tech and Nano-Bionics, University of Science and Technology of China, Hefei, China
- CAS Key Laboratory of Nano-Bio Interface, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou, China
| | - Shazia Fatima
- Nuclear Medicine, Oncology & Radiotherapy Institute (NORI), Islamabad, Pakistan
| | - Sadaf Batool
- Nuclear Medicine, Oncology & Radiotherapy Institute (NORI), Islamabad, Pakistan
| | - Bensheng Qiu
- Biomedical Imaging Center, University of Science and Technology of China, Hefei, Anhui, China
| | - Faisal Shahzad
- Department of Metallurgy and Materials Engineering, Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad, Pakistan
| |
Collapse
|
14
|
Verma M, Chaudhary M, Singh A, Kaur N, Singh N. Naphthalimide-gold-based nanocomposite for the ratiometric detection of okadaic acid in shellfish. J Mater Chem B 2021; 8:8405-8413. [PMID: 32966537 DOI: 10.1039/d0tb01195a] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Okadaic acid (OA) is one of the known marine biotoxins produced by various dinoflagellates and exists in seafood such as shellfish. The consumption of contaminated shellfish with OA leads to diarrheic shellfish poisoning (DSP), which results in the inhibition of protein phosphatase enzymes in humans. This poisoning can cause immunotoxicity and tumor promotion due to the accumulation of okadaic acid in more than the allowed limit in bivalve molluscs. The reported methods for the detection of okadaic acid include mouse bioassays, immunoassays, chromatography coupled with spectroscopic techniques, electrochemical sensors and immunosensors. We have developed a naphthalimide-gold-based nanocomposite for the detection of okadaic acid. Individually, the organic nanoparticles (ONPs) of synthesized naphthalimide-based receptors and gold-coated ONPs are less sensitive for detection. However, fabrication of the composite of Au@ONPs and ONPs enhance the sensing properties and selectivity. The composite shows a ratiometric response in the UV-Vis absorption spectrum and quenching in the fluorescence profile with a detection limit of 20 nM for OA in aqueous medium. In cyclic voltammetry, a shift was observed in the cathodic peak (-0.532 V to -0.618 V) as well as in the anodic peak (-0.815 V to -0.847 V) with the addition of okadaic acid. To study the quick binding of the composite with OA, a time response experiment was performed. Also, the developed sensor retains its sensing ability in the pH range of 5-9 and in high salt conditions. Our developed composite can be used for the detection of OA in real applications.
Collapse
Affiliation(s)
- Meenakshi Verma
- Department of UCRD, Chandigarh University, Ghraun, Mohali, 140413, India
| | - Monika Chaudhary
- Centre for Biomedical Engineering, Indian Institute of Technology Ropar, Roopnagar, Punjab-140001, India
| | - Amanpreet Singh
- Department of Chemistry, Indian Institute of Technology Ropar, Roopnagar, Punjab-140001, India.
| | - Navneet Kaur
- Department of Chemistry, Panjab University, Chandigarh - 160014, India.
| | - Narinder Singh
- Department of Chemistry, Indian Institute of Technology Ropar, Roopnagar, Punjab-140001, India.
| |
Collapse
|
15
|
Nelis JLD, Migliorelli D, Mühlebach L, Generelli S, Stewart L, Elliott CT, Campbell K. Highly sensitive electrochemical detection of the marine toxins okadaic acid and domoic acid with carbon black modified screen printed electrodes. Talanta 2021; 228:122215. [PMID: 33773701 DOI: 10.1016/j.talanta.2021.122215] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 02/07/2021] [Accepted: 02/11/2021] [Indexed: 11/18/2022]
Abstract
A novel electrochemical immunosensor for the detection of the important marine biotoxins domoic acid (DA) and okadaic acid (OA) was developed. The sensors used carbon black modified screen-printed electrodes (CB-SPE) obtained using a high-throughput method. The electrochemical performance and stability of CB modified SPEs and bare carbon SPEs (c-SPEs) were compared using cyclic voltammetry and electrochemical impedance spectroscopy. CB-SPEs showed improved long-term (at least six months) stability and electro-catalytic properties compared with c-SPEs. The CB-SPEs were bio-functionalized with DA or OA protein-conjugates and used to develop two indirect competitive immunosensors using differential pulse voltammetry (DPV). The DPV signals obtained for the OA and DA immunosensors fitted well to four-parameter dose-response curves (R2 > 0.98) and showed excellent LODs (LOD = 1.7 ng mL-1 for DA in buffer; LOD = 1.9 ng mL-1 for DA in mussel extract; LOD = 0.15 ng mL-1 for OA in buffer; LOD = 0.18 ng mL-1 for OA in mussel extract). No significant interference of the naturally co-occurring marine toxins saxitoxin, tetrodotoxin and OA was detected for the DA immunosensor. Similarly, for the OA immunosensor saxitoxin, tetrodotoxin and DA did not cross-react and very limited interference was observed for the dinophysis toxins DTX-1, DTX-2 and DTX-3 (OA congeners). Moreover, both immunosensors remained stable after at least 25 days of storage at 4 °C. This work demonstrates the potential of affordable, mass-produced nanomaterial-modified SPEs for marine toxin detection in shellfish.
Collapse
Affiliation(s)
- Joost L D Nelis
- Institute for Global Food Security, Queen's University, Belfast, 19 Chlorine Gardens, Belfast, BT9 5DL, UK.
| | | | - Lea Mühlebach
- CSEM SA, Bahnhofstrasse 1, 7302, Landquart, Switzerland
| | | | - Linda Stewart
- Institute for Global Food Security, Queen's University, Belfast, 19 Chlorine Gardens, Belfast, BT9 5DL, UK
| | - Christopher T Elliott
- Institute for Global Food Security, Queen's University, Belfast, 19 Chlorine Gardens, Belfast, BT9 5DL, UK
| | - Katrina Campbell
- Institute for Global Food Security, Queen's University, Belfast, 19 Chlorine Gardens, Belfast, BT9 5DL, UK
| |
Collapse
|
16
|
Development of a label-free electrochemical aptasensor based on diazonium electrodeposition: Application to cadmium detection in water. Anal Biochem 2020; 612:113956. [PMID: 32950496 DOI: 10.1016/j.ab.2020.113956] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2020] [Revised: 09/10/2020] [Accepted: 09/14/2020] [Indexed: 02/06/2023]
Abstract
In this study we have developed a new aptasensor for cadmium (Cd2+) detection in water. Gold electrode surface has been chemically modified by electrochemical reduction of diazonium salt (CMA) with carboxylic acid outward from the surface. This was used for amino-modified cadmium aptamer immobilization through carbodiimide reaction. Chemical surface modification was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). This latter was also used for Cd2+ detection. The aptasensor has exhibited a good linear relationship between the logarithm of the Cd2+ concentration and the impedance changes in the range from 10-3 to 10-9 M with a correlation R2 of 0.9954. A high sensitivity was obtained with a low limit of detection (LOD) of 2.75*10-10 M. Moreover, the developed aptasensor showed a high selectivity towards Cd2+ when compared to other interferences such as Hg2+, Pb2+ and Zn2+. The developed aptasensor presents a simple and sensitive approach for Cd2+detection in aqueous solutions with application for trace Cd2+ detection in spring water samples.
Collapse
|
17
|
Gandhi M, Rajagopal D, Senthil Kumar A. Facile Electrochemical Demethylation of 2-Methoxyphenol to Surface-Confined Catechol on the MWCNT and Its Efficient Electrocatalytic Hydrazine Oxidation and Sensing Applications. ACS OMEGA 2020; 5:16208-16219. [PMID: 32656443 PMCID: PMC7346242 DOI: 10.1021/acsomega.0c01846] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Accepted: 06/05/2020] [Indexed: 06/01/2023]
Abstract
Owing to its biological significance, preparation of stable surface-confined catechol (CA) is a long-standing interest in electrochemistry and surface chemistry. In this connection, various chemical approaches such as covalent immobilization (using amine- and carboxylate-functionalized CA, diazotization-based coupling, and Michael addition reaction), self-assembled monolayer on gold (thiol-functionalized CA is assembled on the gold surface), CA adsorption on the ad-layer of a defect-free single-crystal Pt surface, π-π bonding, CA pendant metal complexes, and CA-functionalized polymer-modified electrodes have been reported in the literature. In general, these conventional methods are involved with a series of time-consuming synthetic procedures. Indeed, the preparation of a surface-fouling-free surface-confined system is a challenging task. Herein, we introduce a new and facile approach based on electrochemical demethylation of 2-methoxyphenol as a precursor on the graphitic surface (MWCNT) at a bias potential, 0.5 V vs Ag/AgCl in neutral pH solution. Such an electrochemical performance resulted in the development of a stable and well-defined redox peak at E o' = 0.15 (A2/C2) V vs Ag/AgCl within 10 min of preparation time in pH 7 phosphate buffer solution. Calculated surface excess (16.65 × 10-9 mol cm-2) is about 10-1000 times higher than the values reported with other preparation methods. The product (catechol) formed on the modified electrode was confirmed by collective electrochemical and physicochemical characterizations such as potential segment analysis, TEM, Raman, IR, UV-vis, GC-MS, and NMR spectroscopic techniques, and thin-layer chromatographic studies. The electrocatalytic efficiency of the surface-confined CA system was demonstrated by studying hydrazine oxidation and sensing reactions in a neutral pH solution. This new system is found to be tolerant to various interfering biochemicals such as uric acid, xanthine, hypoxanthine, glucose, nitrate, hydrogen peroxide, ascorbic acid, Cu2+, and Fe2+. Since the approach is simple, rapid, and reproducible, a variety of surface-confined CA systems can be prepared.
Collapse
Affiliation(s)
- Mansi Gandhi
- Nano
and Bioelectrochemistry Research Laboratory, Department of Chemistry,
School of Advanced Sciences, Vellore Institute
of Technology University, Vellore 632014, India
- Department
of Chemistry, School of Advanced Sciences, Vellore Institute of Technology University, Vellore 632014, India
| | - Desikan Rajagopal
- Department
of Chemistry, School of Advanced Sciences, Vellore Institute of Technology University, Vellore 632014, India
| | - Annamalai Senthil Kumar
- Nano
and Bioelectrochemistry Research Laboratory, Department of Chemistry,
School of Advanced Sciences, Vellore Institute
of Technology University, Vellore 632014, India
- Department
of Chemistry, School of Advanced Sciences, Vellore Institute of Technology University, Vellore 632014, India
- Carbon
Dioxide Research and Green Technology Centre, Vellore Institute of Technology University, Vellore Tamil Nadu 632014, India
| |
Collapse
|
18
|
Sharma S, Joshi P, Mehtab S, Zaidi MGH, Singhal K, Siddiqi TI. Development of Non-enzymatic Cholesterol Electrochemical Sensor Based on Polyindole/Tungsten Carbide Nanocomposite. JOURNAL OF ANALYSIS AND TESTING 2020. [DOI: 10.1007/s41664-020-00117-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
19
|
Berg KE, Leroux YR, Hapiot P, Henry CS. Increasing Applications of Graphite Thermoplastic Electrodes with Aryl Diazonium Grafting. ChemElectroChem 2019. [DOI: 10.1002/celc.201901048] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Kathleen E. Berg
- Department of Chemistry Colorado State University 1872 Campus Delivery Fort Collins, CO 80523 USA
| | - Yann R. Leroux
- CNRS, ISCR – UMR 6226 Université de Rennes 1 F-35000 Rennes France
| | - Philippe Hapiot
- CNRS, ISCR – UMR 6226 Université de Rennes 1 F-35000 Rennes France
| | - Charles S. Henry
- Department of Chemistry Colorado State University 1872 Campus Delivery Fort Collins, CO 80523 USA
| |
Collapse
|
20
|
Ramalingam S, Chand R, Singh CB, Singh A. Phosphorene-gold nanocomposite based microfluidic aptasensor for the detection of okadaic acid. Biosens Bioelectron 2019; 135:14-21. [PMID: 30981975 DOI: 10.1016/j.bios.2019.03.056] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Revised: 03/21/2019] [Accepted: 03/26/2019] [Indexed: 11/25/2022]
Abstract
Okadaic acid (OA) is one of the most prevalent and largely distributed bio-toxin in the world. Consumption of OA results in a series of digestive ailments such as nausea and diarrhea. This study demonstrates the preparation and functioning of an electrochemical microfluidic biochip for the detection of OA. The screen-printed carbon electrode (SPCE) was modified by phosphorene-gold nanocomposite onto which an aptamer specific to OA was immobilized. BP-Au nanocomposites were synthesized by an in-situ, one-step method without the use of a reducing agent. Potassium ferro-ferri cyanide was used as a redox pair to quantify signal strength. To improve reaction time, increase sensitivity and portability, a microfluidic platform was designed and developed. This device comprised of channels identified for specific purposes such as sample mixing and incubation. Overall, the integrated system consisted of a polydimethylsiloxane microfluidic chip housing an aptamer modified SPCE, as a single detection module for Okadaic acid. The nanomaterials and the microfluidic channels prepared were spectroscopically and electrochemically analyzed. Differential pulse voltammograms revealed a detection limit of 8 pM, while a linear range was found between 10 nM-250 nM. Selectivity studies were also performed with spiked mussel samples and other interfering species. This point-of-care device can be deployed to perform on-farm assays in fishing units.
Collapse
Affiliation(s)
| | - Rohit Chand
- W. Booth School of Engineering Practice and Technology, McMaster University, Hamilton, ON, L8S 4L8, Canada
| | - Chandra B Singh
- Stored Grains Engineering, School of Engineering, University of South Australia, Adelaide, SA, 5001, Australia
| | - Ashutosh Singh
- School of Engineering, University of Guelph, Guelph, ON, N1G 2W1, Canada.
| |
Collapse
|
21
|
Yugender Goud K, Sunil Kumar V, Hayat A, Vengatajalabathy Gobi K, Song H, Kim KH, Marty JL. A highly sensitive electrochemical immunosensor for zearalenone using screen-printed disposable electrodes. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2018.10.058] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
22
|
Shen Y, Shen G, Zhang Y. Label-Free Electrochemical Immunosensor Based on Ionic Liquid Containing Dialdehyde As a Novel Linking Agent for the Antibody Immobilization. ACS OMEGA 2018; 3:11227-11232. [PMID: 30320258 PMCID: PMC6173497 DOI: 10.1021/acsomega.8b01298] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2018] [Accepted: 08/02/2018] [Indexed: 05/20/2023]
Abstract
Demand for label-free electrochemical immunosensor has resulted in extensive research in improving the conductivity of a sensing interface and antibody immobilization. In this paper, an electrochemical immunosensor for prostate specific antigen based on dialdehyde-functionalized ionic liquid used as a novel linking reagent to replace glutaraldehyde for the antibody immobilization is described. The novel linking reagent enhanced the conductivity of the sensing interface. Thus, the proposed immunosensor had a wider linear range of 0.05-30 ng mL-1, with a lower detection limit of 0.04 ng mL-1 compared with the immunosensor based on glutaraldehyde for the antibody immobilization.
Collapse
Affiliation(s)
- Youming Shen
- Hunan
Province Cooperative Innovation Center for The Construction &
Development of Dongting Lake Ecological Economic Zone, College of
Chemistry and Materials Engineering, Hunan
University of Arts and Science, Changde 415000, P. R. China
- Key
Laboratory of Chemical Biology and Traditional Chinese Medicine Research
(Ministry of Education), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha 410081, P. R. China
| | - Guangyu Shen
- Hunan
Province Cooperative Innovation Center for The Construction &
Development of Dongting Lake Ecological Economic Zone, College of
Chemistry and Materials Engineering, Hunan
University of Arts and Science, Changde 415000, P. R. China
- E-mail:
| | - Youyu Zhang
- Key
Laboratory of Chemical Biology and Traditional Chinese Medicine Research
(Ministry of Education), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha 410081, P. R. China
- E-mail: . Tel/Fax: +86-736-7186115
| |
Collapse
|
23
|
Nawaz MAH, Majdinasab M, Latif U, Nasir M, Gokce G, Anwar MW, Hayat A. Development of a disposable electrochemical sensor for detection of cholesterol using differential pulse voltammetry. J Pharm Biomed Anal 2018; 159:398-405. [DOI: 10.1016/j.jpba.2018.07.005] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Revised: 05/29/2018] [Accepted: 07/06/2018] [Indexed: 12/17/2022]
|
24
|
Yáñez-Sedeño P, Campuzano S, Pingarrón JM. Integrated Affinity Biosensing Platforms on Screen-Printed Electrodes Electrografted with Diazonium Salts. SENSORS 2018; 18:s18020675. [PMID: 29495294 PMCID: PMC5854980 DOI: 10.3390/s18020675] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/29/2018] [Revised: 02/15/2018] [Accepted: 02/20/2018] [Indexed: 02/06/2023]
Abstract
Adequate selection of the electrode surface and the strategies for its modification to enable subsequent immobilization of biomolecules and/or nanomaterials integration play a major role in the performance of electrochemical affinity biosensors. Because of the simplicity, rapidity and versatility, electrografting using diazonium salt reduction is among the most currently used functionalization methods to provide the attachment of an organic layer to a conductive substrate. This particular chemistry has demonstrated to be a powerful tool to covalently immobilize in a stable and reproducible way a wide range of biomolecules or nanomaterials onto different electrode surfaces. Considering the great progress and interesting features arisen in the last years, this paper outlines the potential of diazonium chemistry to prepare single or multianalyte electrochemical affinity biosensors on screen-printed electrodes (SPEs) and points out the existing challenges and future directions in this field.
Collapse
Affiliation(s)
- Paloma Yáñez-Sedeño
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain.
| | - Susana Campuzano
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain.
| | - José M Pingarrón
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain.
| |
Collapse
|
25
|
Pan Y, Wan Z, Zhong L, Li X, Wu Q, Wang J, Wang P. Label-free okadaic acid detection using growth of gold nanoparticles in sensor gaps as a conductive tag. Biomed Microdevices 2017; 19:33. [DOI: 10.1007/s10544-017-0162-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
26
|
Vasilescu A, Nunes G, Hayat A, Latif U, Marty JL. Electrochemical Affinity Biosensors Based on Disposable Screen-Printed Electrodes for Detection of Food Allergens. SENSORS (BASEL, SWITZERLAND) 2016; 16:E1863. [PMID: 27827963 PMCID: PMC5134522 DOI: 10.3390/s16111863] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/21/2016] [Revised: 10/24/2016] [Accepted: 10/31/2016] [Indexed: 01/04/2023]
Abstract
Food allergens are proteins from nuts and tree nuts, fish, shellfish, wheat, soy, eggs or milk which trigger severe adverse reactions in the human body, involving IgE-type antibodies. Sensitive detection of allergens in a large variety of food matrices has become increasingly important considering the emergence of functional foods and new food manufacturing technologies. For example, proteins such as casein from milk or lysozyme and ovalbumin from eggs are sometimes used as fining agents in the wine industry. Nonetheless, allergen detection in processed foods is a challenging endeavor, as allergen proteins are degraded during food processing steps involving heating or fermentation. Detection of food allergens was primarily achieved via Enzyme-Linked Immuno Assay (ELISA) or by chromatographic methods. With the advent of biosensors, electrochemical affinity-based biosensors such as those incorporating antibodies and aptamers as biorecognition elements were also reported in the literature. In this review paper, we highlight the success achieved in the design of electrochemical affinity biosensors based on disposable screen-printed electrodes towards detection of protein allergens. We will discuss the analytical figures of merit for various disposable screen-printed affinity sensors in relation to methodologies employed for immobilization of bioreceptors on transducer surface.
Collapse
Affiliation(s)
- Alina Vasilescu
- International Centre of Biodynamics, 1B Intrarea Portocalelor, sector 6, 060101 Bucharest, Romania.
| | - Gilvanda Nunes
- Technological Chemistry Department, Federal University of Maranhão, CCET/UFMA, Av. Portugueses, Cidade Universitária do Canga, 65080-040 São Luis, MA, Brazil.
| | - Akhtar Hayat
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM) COMSATS Institute of Information Technology (CIIT), 54000 Lahore, Pakistan.
| | - Usman Latif
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM) COMSATS Institute of Information Technology (CIIT), 54000 Lahore, Pakistan.
| | - Jean-Louis Marty
- BAE Laboratory, Université de Perpignan Via Domitia, 52 Avenue Paul Alduy, 66860 Perpignan, France.
| |
Collapse
|
27
|
Detection of bisphenol-A using electrochemical immunosensor: Comparison between competition and displacement format assay. J Electroanal Chem (Lausanne) 2016. [DOI: 10.1016/j.jelechem.2016.05.039] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
28
|
Multiplexed electrochemical immunosensing of obesity-related hormones at grafted graphene-modified electrodes. Electrochim Acta 2016. [DOI: 10.1016/j.electacta.2016.03.140] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
29
|
Diazonium-based impedimetric aptasensor for the rapid label-free detection of Salmonella typhimurium in food sample. Biosens Bioelectron 2016; 80:566-573. [PMID: 26894987 DOI: 10.1016/j.bios.2016.02.024] [Citation(s) in RCA: 92] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2015] [Revised: 02/07/2016] [Accepted: 02/09/2016] [Indexed: 11/24/2022]
Abstract
Fast and accurate detection of microorganisms is of key importance in clinical analysis and in food and water quality monitoring. Salmonella typhimurium is responsible for about a third of all cases of foodborne diseases and consequently, its fast detection is of great importance for ensuring the safety of foodstuffs. We report the development of a label-free impedimetric aptamer-based biosensor for S. typhimurium detection. The aptamer biosensor was fabricated by grafting a diazonium-supporting layer onto screen-printed carbon electrodes (SPEs), via electrochemical or chemical approaches, followed by chemical immobilisation of aminated-aptamer. FTIR-ATR, contact angle and electrochemical measurements were used to monitor the fabrication process. Results showed that electrochemical immobilisation of the diazonium-grafting layer allowed the formation of a denser aptamer layer, which resulted in higher sensitivity. The developed aptamer-biosensor responded linearly, on a logarithm scale, over the concentration range 1 × 10(1) to 1 × 10(8)CFU mL(-1), with a limit of quantification (LOQ) of 1 × 10(1) CFU mL(-1) and a limit of detection (LOD) of 6 CFU mL(-1). Selectivity studies showed that the aptamer biosensor could discriminate S. typhimurium from 6 other model bacteria strains. Finally, recovery studies demonstrated its suitability for the detection of S. typhimurium in spiked (1 × 10(2), 1 × 10(4) and 1 × 10(6) CFU mL(-1)) apple juice samples.
Collapse
|
30
|
Biosensor-Based Technologies for the Detection of Pathogens and Toxins. BIOSENSORS FOR SUSTAINABLE FOOD - NEW OPPORTUNITIES AND TECHNICAL CHALLENGES 2016. [DOI: 10.1016/bs.coac.2016.04.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
|
31
|
The development of an electrochemical immunosensor using a thiol aromatic aldehyde and PAMAM-functionalized Fe3O4@Au nanoparticles. Anal Biochem 2015; 485:66-71. [DOI: 10.1016/j.ab.2015.06.016] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2015] [Revised: 06/07/2015] [Accepted: 06/10/2015] [Indexed: 01/12/2023]
|
32
|
Chrouda A, Sbartai A, Baraket A, Renaud L, Maaref A, Jaffrezic-Renault N. An aptasensor for ochratoxin A based on grafting of polyethylene glycol on a boron-doped diamond microcell. Anal Biochem 2015; 488:36-44. [PMID: 26255699 DOI: 10.1016/j.ab.2015.07.012] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2015] [Revised: 07/19/2015] [Accepted: 07/22/2015] [Indexed: 11/19/2022]
Abstract
A novel strategy for the fabrication of an electrochemical label-free aptasensor for small-size molecules is proposed and demonstrated as an aptasensor for ochratoxin A (OTA). A long spacer chain of polyethylene glycol (PEG) was immobilized on a boron-doped diamond (BDD) microcell via electrochemical oxidation of its terminal amino groups. The amino-aptamer was then covalently linked to the carboxyl end of the immobilized PEG as a two-piece macromolecule, autoassembled at the BDD surface, forming a dense layer. Due to a change in conformation of the aptamer on the target analyte binding, a decrease of the electron transfer rate of the redox [Fe(CN)6](4-/3-) probe was observed. To quantify the amount of OTA, the decrease of the square wave voltammetry (SWV) peak maximum of this probe was monitored. The plot of the peak maximum against the logarithm of OTA concentration was linear along the range from 0.01 to 13.2 ng/L, with a detection limit of 0.01 ng/L. This concept was validated on spiked real samples of rice.
Collapse
Affiliation(s)
- A Chrouda
- Laboratory of Interfaces and Advanced Materials, University of Monastir, 5019 Monastir, Tunisia; University of Lyon, Institute of Analytical Sciences, UMR CNRS 5280, 69100 Villeurbanne, France
| | - A Sbartai
- University of Lyon, Institute of Analytical Sciences, UMR CNRS 5280, 69100 Villeurbanne, France
| | - A Baraket
- University of Lyon, Institute of Analytical Sciences, UMR CNRS 5280, 69100 Villeurbanne, France
| | - L Renaud
- University of Lyon, Institute of Nanotechnology of Lyon, UMR CNRS 5270, 69622 Villeurbanne Cedex, France
| | - A Maaref
- Laboratory of Interfaces and Advanced Materials, University of Monastir, 5019 Monastir, Tunisia
| | - N Jaffrezic-Renault
- University of Lyon, Institute of Analytical Sciences, UMR CNRS 5280, 69100 Villeurbanne, France.
| |
Collapse
|
33
|
Shen Y, Zhang Y, Liu M, Liu X, Guo H, Zhang X, Zhang C, Li H, Yao S. A simple and sensitive electrochemical immunosensor based on thiol aromatic aldehyde as a substrate for the antibody immobilization. Talanta 2015; 141:288-92. [DOI: 10.1016/j.talanta.2015.04.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2015] [Revised: 03/24/2015] [Accepted: 04/02/2015] [Indexed: 11/27/2022]
|
34
|
Misni M, Sathishkumar P, Ahamad R, MohdYusoff AR. Determination of para-arsanilic acid with improved diazotization reaction using differential pulse cathodic stripping voltammetry in aqueous system. ENVIRONMENTAL TECHNOLOGY 2015; 36:2249-2254. [PMID: 25749108 DOI: 10.1080/09593330.2015.1025105] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Para-arsanilic acid (p-ASA) has been widely used in the poultry industry to promote growth and prevent dysentery. It is excreted unchanged in the manure and released into non-target sites causing organoarsenic pollution risk to the environment and living system. Therefore, simple and effective analytical strategies are demanded for determining the samples that contain p-ASA. However, direct determination of both p-ASA and ortho-arsanilic acid (o-ASA) using differential pulse cathodic stripping voltammetry (DPCSV) gives the similar voltammograms that directly hamper the analysis used by the DPCSV technique. In this study, a method to determine and differentiate p-ASA from o-ASA via diazotization and coupling reaction of the amine groups followed by the direct DPCSV determination of diazo compounds is presented. The diazotization reaction carried out at pH 1.5 and 0 ± 1°C for 10 min showed two reduction peaks in DPCSV at-70 mV and -440 mV vs. Ag/AgCl (KCl 3 M). However, when the diazotization reaction was performed at pH 12.5 and 0 ± 1°C for 40 min, a coloured azo compound was produced and the DPCSV showed only one reduction peak that appeared at -600 mV vs. Ag/AgCl (3 M of KCl). The results of this study show that only p-ASA compound gave a reduction peak, whereas o-ASA compound did not give any peak. The detection limit of p-ASA was found to be 4 × 10(-8 )M. As a result, the proposed electro-analytical technique might be a good candidate to determine and differentiate the p-ASA present in the poultry and environmental samples.
Collapse
Affiliation(s)
- Marpongahtun Misni
- a Institute of Environmental and Water Resource Management , Universiti Teknologi Malaysia , 81310 Skudai, Bahru , Johor , Malaysia
| | | | | | | |
Collapse
|
35
|
One-step immobilization of antibodies for α-1-fetoprotein immunosensor based on dialdehyde cellulose/ionic liquid composite. Anal Biochem 2015; 471:38-43. [DOI: 10.1016/j.ab.2014.09.020] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2014] [Revised: 09/05/2014] [Accepted: 09/26/2014] [Indexed: 11/21/2022]
|
36
|
Aptamer-based competitive electrochemical biosensor for brevetoxin-2. Biosens Bioelectron 2015; 69:148-54. [PMID: 25725463 DOI: 10.1016/j.bios.2015.01.055] [Citation(s) in RCA: 111] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2014] [Revised: 01/22/2015] [Accepted: 01/23/2015] [Indexed: 11/21/2022]
Abstract
Brevetoxins (BTXs) are very potent marine neurotoxins that increased in geographical distribution in the past decade causing the illness clinically described as neurological shellfish poisoning (NSP). The ethical problems as well as the technical difficulties associated with the currently employed analysis methods for marine toxins are encouraging the research for suitable alternatives to be applied in a regulatory monitoring regime. Here, we report an electrochemical biosensor platform for BTX-2 detection utilising aptamer as specific receptor. Using in vitro selection, high affinity DNA aptamers to BTX-2 were successfully selected for the first time from a large pool of random sequences. The binding of BTX-2 to aptamer pools/clones was monitored using fluorescence and electrochemical impedance spectroscopy (EIS). The aptamer BT10 exhibited the highest binding affinity to BTX-2, with a dissociation constant of 42nM. The effects of the incubation time, pH and metal ions concentrations on the aptamer-toxin binding were studied. The aptamer BT10 was used to construct a label-free competitive impedimetric biosensor for BTX-2 achieving a detection limit of 106pg/ml. We observed a high degree of cross reactivity of the selected aptamer to the two similar congeners, BTX-2 and -3, whereas no cross reactivity to other marine toxins was obtained. Moreover, the aptasensor was applied for the detection of BTX-2 in spiked shellfish extract showing a very high recovery percentage. We believe that the proposed aptasensor will facilitate the routine detection of BTX-2 in food samples.
Collapse
|
37
|
Hayat A, Marty JL. Aptamer based electrochemical sensors for emerging environmental pollutants. Front Chem 2014; 2:41. [PMID: 25019067 PMCID: PMC4071757 DOI: 10.3389/fchem.2014.00041] [Citation(s) in RCA: 88] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2014] [Accepted: 06/09/2014] [Indexed: 12/30/2022] Open
Abstract
Environmental contaminants monitoring is one of the key issues in understanding and managing hazards to human health and ecosystems. In this context, aptamer based electrochemical sensors have achieved intense significance because of their capability to resolve a potentially large number of problems and challenges in environmental contamination. An aptasensor is a compact analytical device incorporating an aptamer (oligonulceotide) as the sensing element either integrated within or intimately associated with a physiochemical transducer surface. Nucleic acid is well known for the function of carrying and passing genetic information, however, it has found a key role in analytical monitoring during recent years. Aptamer based sensors represent a novelty in environmental analytical science and there are great expectations for their promising performance as alternative to conventional analytical tools. This review paper focuses on the recent advances in the development of aptamer based electrochemical sensors for environmental applications with special emphasis on emerging pollutants.
Collapse
Affiliation(s)
- Akhtar Hayat
- BIOMEM, Université de Perpignan Perpignan, France ; Interdisciplinary Research Centre in Biomedical Materials, COMSATS Institute of Information Technology Lahore, Pakistan
| | - Jean L Marty
- BIOMEM, Université de Perpignan Perpignan, France
| |
Collapse
|
38
|
Lipoprotein(a) determination in human serum using a nitrilotriacetic acid derivative immunosensing scaffold on disposable electrodes. Anal Bioanal Chem 2014; 406:5379-87. [DOI: 10.1007/s00216-014-7964-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2014] [Revised: 05/20/2014] [Accepted: 06/10/2014] [Indexed: 02/02/2023]
|
39
|
Taleat Z, Khoshroo A, Mazloum-Ardakani M. Screen-printed electrodes for biosensing: a review (2008–2013). Mikrochim Acta 2014. [DOI: 10.1007/s00604-014-1181-1] [Citation(s) in RCA: 209] [Impact Index Per Article: 20.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
40
|
Eissa S, Ng A, Siaj M, Tavares AC, Zourob M. Selection and identification of DNA aptamers against okadaic acid for biosensing application. Anal Chem 2013; 85:11794-801. [PMID: 24164310 DOI: 10.1021/ac402220k] [Citation(s) in RCA: 101] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
This work describes the selection and identification of DNA aptamers that bind with high affinity and specificity to okadaic acid (OA), a lipophilic marine biotoxin that accumulates in shellfish. The aptamers selected using systematic evolution of ligands by exponential enrichment (SELEX) exhibited dissociation constants in the nanomolar range. The aptamer with the highest affinity was then used for the fabrication of a label-free electrochemical biosensor for okadaic acid detection. The aptamer was first immobilized on the gold electrode by a self-assembly approach through Au-S interaction. The binding of okadaic acid to the aptamer immobilized on the electrode surface induces an alteration of the aptamer conformation causing a significant decrease in the electron-transfer resistance monitored by electrochemical impedance spectroscopy. The aptasensor showed a linear range for the concentrations of OA between 100 pg/mL and 60 ng/mL with a detection limit of 70 pg/mL. The dissociation constant of okadaic acid with the aptamer immobilized on the electrode surface showed good agreement with that determined using fluorescence assay in solution. Moreover, the aptasensor did not show cross-reactivity toward toxins with structures similar to okadaic acid such as dinophysis toxin-1 and 2 (DTX-1, DTX-2). Further biosensing applications of the selected aptamers are expected to offer promising alternatives to the traditional analytical and immunological methods for OA detection.
Collapse
Affiliation(s)
- Shimaa Eissa
- Institut National de la Recherche Scientifique, Centre-Énergie, Matériaux et Télécommunications , 1650 Boulevard Lionel Boulet, Varennes, Québec J3X 1S2, Canada
| | | | | | | | | |
Collapse
|
41
|
An Immunosensor for Pathogenic Staphylococcus aureus Based on Antibody Modified Aminophenyl-Au Electrode. ACTA ACUST UNITED AC 2013. [DOI: 10.1155/2013/367872] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
The objective of this work is to elaborate an immunosensing system which will detect and quantify Staphylococcus aureus bacteria. A gold electrode was modified by electrografting of 4-nitrophenyl diazonium, in situ synthesized in acidic aqueous solution. The immunosensor was fabricated by immobilizing affinity-purified polyclonal anti S. aureus antibodies on the modified gold electrode. Cyclic voltammetry (CV) and Faradaic Electrochemical Impedance Spectroscopy (EIS) were employed to characterize the stepwise assembly of the immunosensor. The performance of the developed immunosensor was evaluated by monitoring the electron-transfer resistance detected using Faradaic EIS. The experimental results indicated a linear relationship between the relative variation of the electron transfer resistance and the logarithmic value of S. aureus concentration, with a slope of 0.40 ± 0.08 per decade of concentration. A low quantification limit of 10±2 CFU per ml and a linear range up to 107±2×106 CFU per mL were obtained. The developed immunosensors showed high selectivity to Escherichia coli and Staphylococcus saprophyticus.
Collapse
|
42
|
Albert J, Lepinay S, Caucheteur C, DeRosa MC. High resolution grating-assisted surface plasmon resonance fiber optic aptasensor. Methods 2013; 63:239-54. [DOI: 10.1016/j.ymeth.2013.07.007] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2013] [Revised: 05/07/2013] [Accepted: 07/02/2013] [Indexed: 01/05/2023] Open
|
43
|
Development of electrochemical immunosensors towards point of care diagnostics. Biosens Bioelectron 2013; 47:1-11. [DOI: 10.1016/j.bios.2013.02.045] [Citation(s) in RCA: 172] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2013] [Revised: 02/27/2013] [Accepted: 02/28/2013] [Indexed: 12/21/2022]
|
44
|
Shen Q, Gong L, Baibado JT, Dong W, Wang Y, Dai Z, Cheung HY. Graphene based pipette tip solid phase extraction of marine toxins in shellfish muscle followed by UPLC-MS/MS analysis. Talanta 2013; 116:770-5. [PMID: 24148472 DOI: 10.1016/j.talanta.2013.07.042] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2013] [Revised: 07/17/2013] [Accepted: 07/21/2013] [Indexed: 11/15/2022]
Abstract
Graphene is a novel carbonic material with great potentials for the use as sorbent due to its ultrahigh surface area. Herein, we report the use of graphene as sorbent in solid-phase extraction (SPE) using pipette tip as cartridge namely GPT-SPE, together with ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS), for the analysis of lipophilic marine toxins (LMTs), including yessotoxins (YTX), okadaic acid (OA), dinophysistoxin-1 (DTX1), gymnodimine (GYM), spirolides-1 (SPX1), pectenotoxin-2 (PTX2) and azaspiracid-1 (AZA1) in shellfish. The GPT-SPE procedure was optimized and the performance of graphene was fully validated. Results with high-sensitivity and good reproducibility was obtained and compared with that of other sorbents like C18 silica, multi-walled carbon nanotubes (MWCNTs), commercial Oasis HLB, and Strata-X for the extraction of LMTs, which showed superiority and advantages of graphene, such as good recoveries, stability and compatibility with various solvents. In order to exhibit the potentials of graphene as an excellent sorbent material, 67 mussel samples from six coastal cities of China were analyzed. OA was found to be the dominant contaminant, while YTX was also detected with low level.
Collapse
Affiliation(s)
- Qing Shen
- Department of Biology and Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong
| | | | | | | | | | | | | |
Collapse
|
45
|
Hayat A, Andreescu S, Marty JL. Design of PEG-aptamer two piece macromolecules as convenient and integrated sensing platform: application to the label free detection of small size molecules. Biosens Bioelectron 2013; 45:168-73. [PMID: 23500359 DOI: 10.1016/j.bios.2013.01.059] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2012] [Revised: 01/10/2013] [Accepted: 01/21/2013] [Indexed: 10/27/2022]
Abstract
A novel strategy for the fabrication of electrochemical label free aptasensor for small size molecules is purposed, and the strategy has been demonstrated by the development of an aptasensor for ochratoxin (A). A long spacer chain of polyethylene glycol (PEG) was immobilized on screen printed carbon electrode (SPCE) via electrochemical oxidation of its terminal amino-group. The amino-aptamer was covalently linked to carboxy end of immobilized PEG to form two piece macromolecules. The designed immobilized macromolecules resulted in the formation of long tunnels on SPCE surface, while aptamer acted as gate of the tunnels. The aptamer gates were closed due to change in conformation of aptamer upon target analyte binding, decreasing the electrochemical signal. The decrease in electrochemical signal was used for the detection of target molecule.
Collapse
Affiliation(s)
- Akhtar Hayat
- BIOMEM, Universite´de Perpignan, 52 Avenue Paul Alduy, 66860 Perpignan Cedex, France.
| | | | | |
Collapse
|
46
|
Bouden S, Chaussé A, Dorbes S, El Tall O, Bellakhal N, Dachraoui M, Vautrin-Ul C. Trace lead analysis based on carbon-screen-printed-electrodes modified via 4-carboxy-phenyl diazonium salt electroreduction. Talanta 2013; 106:414-21. [PMID: 23598146 DOI: 10.1016/j.talanta.2013.01.021] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2012] [Revised: 01/06/2013] [Accepted: 01/11/2013] [Indexed: 10/27/2022]
Abstract
This paper describes the use of 4-carboxyphenyl-grafted screen-printed carbon electrodes (4-CP-SPEs) for trace lead analysis. These novel and simple use of electrodes were easily prepared by the electrochemical reduction of the corresponding diazonium salt. Pb detection was then performed by a three-steps method in order to avoid oxygen interference: (i) immersion of the grafted screen-printed electrode (SPE) in the sample and adsorption of Pb(II), (ii) reduction of adsorbed Pb(II) by chronoamperometry (CA), and (iii) oxidation of Pb by Anodic Square Wave Voltammetry (SWV). The reoxidation response was exploited for lead detection and quantification. In order to optimize the analytical responses, the influence of the adsorption medium pH and the adsorption time were investigated. Moreover, an interference study was carried out with Cu(II), Hg(II), Al(III), Mn(II), Zn(II), Cd(II) and no major interference can be expected to quantify Pb(II). The described method provided a limit of detection and a limit of quantification of 1.2 × 10(-9)M and 4.1 × 10(-9)M, respectively. These performances indicate that the 4-CP-SPE could be considered as an efficient tool for environmental analysis.
Collapse
Affiliation(s)
- Sarra Bouden
- Laboratoire Analyse et Modélisation pour la Biologie et l'Environnement, UMR 8587, CNRS-Université Evry Val d'Essonne-CEA, 1 rue du père Jarlan, 91025 Evry Cedex, France
| | | | | | | | | | | | | |
Collapse
|
47
|
Sassolas A, Hayat A, Catanante G, Marty JL. Detection of the marine toxin okadaic acid: Assessing seafood safety. Talanta 2013; 105:306-16. [DOI: 10.1016/j.talanta.2012.10.049] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2012] [Revised: 10/10/2012] [Accepted: 10/13/2012] [Indexed: 10/27/2022]
|
48
|
Kanso H, Barthelmebs L, Inguimbert N, Noguer T. Immunosensors for Estradiol and Ethinylestradiol Based on New Synthetic Estrogen Derivatives: Application to Wastewater Analysis. Anal Chem 2013; 85:2397-404. [DOI: 10.1021/ac303406c] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Affiliation(s)
- Hussein Kanso
- Univ. Perpignan Via Domitia, Institut de Modélisation et d’Analyse
en Géo-Environnement et Santé, EA 4218, F-66860, Perpignan,
France
| | - Lise Barthelmebs
- Univ. Perpignan Via Domitia, Institut de Modélisation et d’Analyse
en Géo-Environnement et Santé, EA 4218, F-66860, Perpignan,
France
| | - Nicolas Inguimbert
- Univ. Perpignan Via Domitia, Laboratoire de Chimie des Biomolécules
et de l′Environnement, EA 4215, F-66860, Perpignan, France
| | - Thierry Noguer
- Univ. Perpignan Via Domitia, Institut de Modélisation et d’Analyse
en Géo-Environnement et Santé, EA 4218, F-66860, Perpignan,
France
| |
Collapse
|
49
|
Hayat A, Haider W, Rolland M, Marty JL. Electrochemical grafting of long spacer arms of hexamethyldiamine on a screen printed carbon electrode surface: application in target induced ochratoxin A electrochemical aptasensor. Analyst 2013; 138:2951-7. [DOI: 10.1039/c3an00158j] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
50
|
Eissa S, Zourob M. A graphene-based electrochemical competitive immunosensor for the sensitive detection of okadaic acid in shellfish. NANOSCALE 2012; 4:7593-7599. [PMID: 23108911 DOI: 10.1039/c2nr32146g] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
A novel graphene-based voltammetric immunosensor for sensitive detection of okadaic acid (OA) was developed. A simple and efficient electrografting method was utilized to functionalize graphene-modified screen-printed carbon electrodes (GSPE) by the electrochemical reduction of in situ generated 4-carboxyphenyl diazonium salt in acidic aqueous solution. Next, the okadaic acid antibody was covalently immobilized on the carboxyphenyl modified graphene electrodes via carbodiimide chemistry. Square wave voltammetry (SWV) was used to investigate the stepwise assembly of the immunosensor. A competitive assay between OA and a fixed concentration of okadaic acid-ovalbumin conjugate (OA-OVA) for the immobilized antibodies was employed for the detection of okadaic acid. The decrease of the [Fe(CN)(6)](3-/4-) reduction peak current in the square wave voltammetry for various concentrations of okadaic acid was used for establishing the calibration curve. A linear relationship between the SWV peak current difference and OA concentration was obtained up to ~5000 ng L(-1). The developed immunosensor allowed a detection limit of 19 ng L(-1) of OA in PBS buffer. The matrix effect studied with spiked shellfish tissue extracts showed a good percentage of recovery and the method was also validated with certified reference mussel samples.
Collapse
Affiliation(s)
- Shimaa Eissa
- Institut national de la recherche scientifique, Centre - Energie, Matériaux et Télécommunications, 1650, Boul. Lionel Boulet, Varennes, Québec J3X 1S2, Canada
| | | |
Collapse
|