• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4641089)   Today's Articles (4040)   Subscriber (50405)
For: Hayat A, Barthelmebs L, Sassolas A, Marty JL. An electrochemical immunosensor based on covalent immobilization of okadaic acid onto screen printed carbon electrode via diazotization-coupling reaction. Talanta 2011;85:513-8. [DOI: 10.1016/j.talanta.2011.04.034] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2011] [Revised: 03/30/2011] [Accepted: 04/11/2011] [Indexed: 11/25/2022]
Number Cited by Other Article(s)
1
Tariq A, Bilal S, Naz I, Nawaz MH, Andreescu S, Jubeen F, Arif A, Hayat A. A multifunctional N-GO/PtCo nanocomposite bridged carbon fiber interface for the electrochemical aptasensing of CA15-3 oncomarker. Anal Biochem 2024;695:115640. [PMID: 39142532 DOI: 10.1016/j.ab.2024.115640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2024] [Revised: 08/03/2024] [Accepted: 08/12/2024] [Indexed: 08/16/2024]
2
Hou J, Xia B, Niu K, Wang J, Li J, Wang N. Ultrasensitive optical fiber SPR sensor enhanced by Au-NPs-film modified with functionalized CQDs for label-free detecting cobalt (II) ion. Anal Chim Acta 2024;1320:343030. [PMID: 39142794 DOI: 10.1016/j.aca.2024.343030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 07/23/2024] [Accepted: 07/24/2024] [Indexed: 08/16/2024]
3
Tiwari MS, Kadu AK. Thiol-based chemically modified carbon screen-printed electrode for simultaneous quantification of trace level Pb(II) and Cd(II). ANAL SCI 2024;40:1449-1457. [PMID: 38740715 PMCID: PMC11269355 DOI: 10.1007/s44211-024-00581-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Accepted: 04/15/2024] [Indexed: 05/16/2024]
4
Ji Y, Wang R, Zhao H. Toward Sensitive and Reliable Immunoassays of Marine Biotoxins: From Rational Design to Food Analysis. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2024;72:16076-16094. [PMID: 39010820 DOI: 10.1021/acs.jafc.4c01865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/17/2024]
5
Li S, Gong L, Wu X, Liu X, Bai N, Guo Y, Liu X, Zhang H, Fu H, Shou Q. Load-bearing columns inspired fabrication of ductile and mechanically enhanced BSA hydrogels. Int J Biol Macromol 2024;261:129910. [PMID: 38309395 DOI: 10.1016/j.ijbiomac.2024.129910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 01/21/2024] [Accepted: 01/31/2024] [Indexed: 02/05/2024]
6
Ndhlala AR, Kavaz Yüksel A, Çelebi N, Doğan HÖ. A General Review of Methodologies Used in the Determination of Cholesterol (C27H46O) Levels in Foods. Foods 2023;12:4424. [PMID: 38137228 PMCID: PMC10742886 DOI: 10.3390/foods12244424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 12/05/2023] [Accepted: 12/08/2023] [Indexed: 12/24/2023]  Open
7
Ji Y, Cai G, Liang C, Gao Z, Lin W, Ming Z, Feng S, Zhao H. A microfluidic immunosensor based on magnetic separation for rapid detection of okadaic acid in marine shellfish. Anal Chim Acta 2023;1239:340737. [PMID: 36628732 DOI: 10.1016/j.aca.2022.340737] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Revised: 12/18/2022] [Accepted: 12/20/2022] [Indexed: 12/24/2022]
8
de Souza Freire L, Ruzo CM, Salgado BB, Gandarilla AMD, Romaguera-Barcelay Y, Tavares APM, Sales MGF, Cordeiro I, Lalwani JDB, Matos R, Fonseca Filho H, Astolfi-Filho S, Ţălu Ş, Lalwani P, Brito WR. An Electrochemical Immunosensor Based on Carboxylated Graphene/SPCE for IgG-SARS-CoV-2 Nucleocapsid Determination. BIOSENSORS 2022;12:bios12121161. [PMID: 36551128 PMCID: PMC9775996 DOI: 10.3390/bios12121161] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 12/01/2022] [Accepted: 12/04/2022] [Indexed: 05/14/2023]
9
Development of a Chemiluminescent Method in a Microfluidic Device for Ultrasensitive Determination of Okadaic Acid with Highly Efficient Aptamer-Based Isolation. SEPARATIONS 2022. [DOI: 10.3390/separations9110350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]  Open
10
Kweon SY, Park JP, Park CY, Park TJ. Graphene Oxide-Mediated Fluorometric Aptasensor for Okadaic Acid Detection. BIOCHIP JOURNAL 2022. [DOI: 10.1007/s13206-022-00056-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
11
Bilal S, Sami AJ, Hayat A, Fayyaz Ur Rehman M. Assessment of pesticide induced inhibition of Apis mellifera (honeybee) acetylcholinesterase by means of N-doped carbon dots/BSA nanocomposite modified electrochemical biosensor. Bioelectrochemistry 2022;144:107999. [PMID: 34801807 DOI: 10.1016/j.bioelechem.2021.107999] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Revised: 11/04/2021] [Accepted: 11/09/2021] [Indexed: 11/30/2022]
12
Sainz R, Pozo MD, Vázquez L, Vilas-Varela M, Castro-Esteban J, Blanco E, Petit-Domínguez MD, Quintana C, Casero E. Lactate biosensing based on covalent immobilization of lactate oxidase onto chevron-like graphene nanoribbons via diazotization-coupling reaction. Anal Chim Acta 2022;1208:339851. [DOI: 10.1016/j.aca.2022.339851] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 04/05/2022] [Accepted: 04/16/2022] [Indexed: 01/04/2023]
13
Zahra QUA, Fang X, Luo Z, Ullah S, Fatima S, Batool S, Qiu B, Shahzad F. Graphene Based Nanohybrid Aptasensors in Environmental Monitoring: Concepts, Design and Future Outlook. Crit Rev Anal Chem 2022;53:1433-1454. [PMID: 35085047 DOI: 10.1080/10408347.2022.2025758] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023]
14
Verma M, Chaudhary M, Singh A, Kaur N, Singh N. Naphthalimide-gold-based nanocomposite for the ratiometric detection of okadaic acid in shellfish. J Mater Chem B 2021;8:8405-8413. [PMID: 32966537 DOI: 10.1039/d0tb01195a] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
15
Nelis JLD, Migliorelli D, Mühlebach L, Generelli S, Stewart L, Elliott CT, Campbell K. Highly sensitive electrochemical detection of the marine toxins okadaic acid and domoic acid with carbon black modified screen printed electrodes. Talanta 2021;228:122215. [PMID: 33773701 DOI: 10.1016/j.talanta.2021.122215] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 02/07/2021] [Accepted: 02/11/2021] [Indexed: 11/18/2022]
16
Development of a label-free electrochemical aptasensor based on diazonium electrodeposition: Application to cadmium detection in water. Anal Biochem 2020;612:113956. [PMID: 32950496 DOI: 10.1016/j.ab.2020.113956] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2020] [Revised: 09/10/2020] [Accepted: 09/14/2020] [Indexed: 02/06/2023]
17
Gandhi M, Rajagopal D, Senthil Kumar A. Facile Electrochemical Demethylation of 2-Methoxyphenol to Surface-Confined Catechol on the MWCNT and Its Efficient Electrocatalytic Hydrazine Oxidation and Sensing Applications. ACS OMEGA 2020;5:16208-16219. [PMID: 32656443 PMCID: PMC7346242 DOI: 10.1021/acsomega.0c01846] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Accepted: 06/05/2020] [Indexed: 06/01/2023]
18
Sharma S, Joshi P, Mehtab S, Zaidi MGH, Singhal K, Siddiqi TI. Development of Non-enzymatic Cholesterol Electrochemical Sensor Based on Polyindole/Tungsten Carbide Nanocomposite. JOURNAL OF ANALYSIS AND TESTING 2020. [DOI: 10.1007/s41664-020-00117-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
19
Berg KE, Leroux YR, Hapiot P, Henry CS. Increasing Applications of Graphite Thermoplastic Electrodes with Aryl Diazonium Grafting. ChemElectroChem 2019. [DOI: 10.1002/celc.201901048] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
20
Ramalingam S, Chand R, Singh CB, Singh A. Phosphorene-gold nanocomposite based microfluidic aptasensor for the detection of okadaic acid. Biosens Bioelectron 2019;135:14-21. [PMID: 30981975 DOI: 10.1016/j.bios.2019.03.056] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Revised: 03/21/2019] [Accepted: 03/26/2019] [Indexed: 11/25/2022]
21
Yugender Goud K, Sunil Kumar V, Hayat A, Vengatajalabathy Gobi K, Song H, Kim KH, Marty JL. A highly sensitive electrochemical immunosensor for zearalenone using screen-printed disposable electrodes. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2018.10.058] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
22
Shen Y, Shen G, Zhang Y. Label-Free Electrochemical Immunosensor Based on Ionic Liquid Containing Dialdehyde As a Novel Linking Agent for the Antibody Immobilization. ACS OMEGA 2018;3:11227-11232. [PMID: 30320258 PMCID: PMC6173497 DOI: 10.1021/acsomega.8b01298] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2018] [Accepted: 08/02/2018] [Indexed: 05/20/2023]
23
Nawaz MAH, Majdinasab M, Latif U, Nasir M, Gokce G, Anwar MW, Hayat A. Development of a disposable electrochemical sensor for detection of cholesterol using differential pulse voltammetry. J Pharm Biomed Anal 2018;159:398-405. [DOI: 10.1016/j.jpba.2018.07.005] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Revised: 05/29/2018] [Accepted: 07/06/2018] [Indexed: 12/17/2022]
24
Yáñez-Sedeño P, Campuzano S, Pingarrón JM. Integrated Affinity Biosensing Platforms on Screen-Printed Electrodes Electrografted with Diazonium Salts. SENSORS 2018;18:s18020675. [PMID: 29495294 PMCID: PMC5854980 DOI: 10.3390/s18020675] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/29/2018] [Revised: 02/15/2018] [Accepted: 02/20/2018] [Indexed: 02/06/2023]
25
Pan Y, Wan Z, Zhong L, Li X, Wu Q, Wang J, Wang P. Label-free okadaic acid detection using growth of gold nanoparticles in sensor gaps as a conductive tag. Biomed Microdevices 2017;19:33. [DOI: 10.1007/s10544-017-0162-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
26
Vasilescu A, Nunes G, Hayat A, Latif U, Marty JL. Electrochemical Affinity Biosensors Based on Disposable Screen-Printed Electrodes for Detection of Food Allergens. SENSORS (BASEL, SWITZERLAND) 2016;16:E1863. [PMID: 27827963 PMCID: PMC5134522 DOI: 10.3390/s16111863] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/21/2016] [Revised: 10/24/2016] [Accepted: 10/31/2016] [Indexed: 01/04/2023]
27
Detection of bisphenol-A using electrochemical immunosensor: Comparison between competition and displacement format assay. J Electroanal Chem (Lausanne) 2016. [DOI: 10.1016/j.jelechem.2016.05.039] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
28
Multiplexed electrochemical immunosensing of obesity-related hormones at grafted graphene-modified electrodes. Electrochim Acta 2016. [DOI: 10.1016/j.electacta.2016.03.140] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
29
Diazonium-based impedimetric aptasensor for the rapid label-free detection of Salmonella typhimurium in food sample. Biosens Bioelectron 2016;80:566-573. [PMID: 26894987 DOI: 10.1016/j.bios.2016.02.024] [Citation(s) in RCA: 92] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2015] [Revised: 02/07/2016] [Accepted: 02/09/2016] [Indexed: 11/24/2022]
30
Biosensor-Based Technologies for the Detection of Pathogens and Toxins. BIOSENSORS FOR SUSTAINABLE FOOD - NEW OPPORTUNITIES AND TECHNICAL CHALLENGES 2016. [DOI: 10.1016/bs.coac.2016.04.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
31
The development of an electrochemical immunosensor using a thiol aromatic aldehyde and PAMAM-functionalized Fe3O4@Au nanoparticles. Anal Biochem 2015;485:66-71. [DOI: 10.1016/j.ab.2015.06.016] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2015] [Revised: 06/07/2015] [Accepted: 06/10/2015] [Indexed: 01/12/2023]
32
Chrouda A, Sbartai A, Baraket A, Renaud L, Maaref A, Jaffrezic-Renault N. An aptasensor for ochratoxin A based on grafting of polyethylene glycol on a boron-doped diamond microcell. Anal Biochem 2015;488:36-44. [PMID: 26255699 DOI: 10.1016/j.ab.2015.07.012] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2015] [Revised: 07/19/2015] [Accepted: 07/22/2015] [Indexed: 11/19/2022]
33
Shen Y, Zhang Y, Liu M, Liu X, Guo H, Zhang X, Zhang C, Li H, Yao S. A simple and sensitive electrochemical immunosensor based on thiol aromatic aldehyde as a substrate for the antibody immobilization. Talanta 2015;141:288-92. [DOI: 10.1016/j.talanta.2015.04.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2015] [Revised: 03/24/2015] [Accepted: 04/02/2015] [Indexed: 11/27/2022]
34
Misni M, Sathishkumar P, Ahamad R, MohdYusoff AR. Determination of para-arsanilic acid with improved diazotization reaction using differential pulse cathodic stripping voltammetry in aqueous system. ENVIRONMENTAL TECHNOLOGY 2015;36:2249-2254. [PMID: 25749108 DOI: 10.1080/09593330.2015.1025105] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
35
One-step immobilization of antibodies for α-1-fetoprotein immunosensor based on dialdehyde cellulose/ionic liquid composite. Anal Biochem 2015;471:38-43. [DOI: 10.1016/j.ab.2014.09.020] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2014] [Revised: 09/05/2014] [Accepted: 09/26/2014] [Indexed: 11/21/2022]
36
Aptamer-based competitive electrochemical biosensor for brevetoxin-2. Biosens Bioelectron 2015;69:148-54. [PMID: 25725463 DOI: 10.1016/j.bios.2015.01.055] [Citation(s) in RCA: 111] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2014] [Revised: 01/22/2015] [Accepted: 01/23/2015] [Indexed: 11/21/2022]
37
Hayat A, Marty JL. Aptamer based electrochemical sensors for emerging environmental pollutants. Front Chem 2014;2:41. [PMID: 25019067 PMCID: PMC4071757 DOI: 10.3389/fchem.2014.00041] [Citation(s) in RCA: 88] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2014] [Accepted: 06/09/2014] [Indexed: 12/30/2022]  Open
38
Lipoprotein(a) determination in human serum using a nitrilotriacetic acid derivative immunosensing scaffold on disposable electrodes. Anal Bioanal Chem 2014;406:5379-87. [DOI: 10.1007/s00216-014-7964-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2014] [Revised: 05/20/2014] [Accepted: 06/10/2014] [Indexed: 02/02/2023]
39
Taleat Z, Khoshroo A, Mazloum-Ardakani M. Screen-printed electrodes for biosensing: a review (2008–2013). Mikrochim Acta 2014. [DOI: 10.1007/s00604-014-1181-1] [Citation(s) in RCA: 209] [Impact Index Per Article: 20.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
40
Eissa S, Ng A, Siaj M, Tavares AC, Zourob M. Selection and identification of DNA aptamers against okadaic acid for biosensing application. Anal Chem 2013;85:11794-801. [PMID: 24164310 DOI: 10.1021/ac402220k] [Citation(s) in RCA: 101] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
41
An Immunosensor for Pathogenic Staphylococcus aureus Based on Antibody Modified Aminophenyl-Au Electrode. ACTA ACUST UNITED AC 2013. [DOI: 10.1155/2013/367872] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
42
Albert J, Lepinay S, Caucheteur C, DeRosa MC. High resolution grating-assisted surface plasmon resonance fiber optic aptasensor. Methods 2013;63:239-54. [DOI: 10.1016/j.ymeth.2013.07.007] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2013] [Revised: 05/07/2013] [Accepted: 07/02/2013] [Indexed: 01/05/2023]  Open
43
Development of electrochemical immunosensors towards point of care diagnostics. Biosens Bioelectron 2013;47:1-11. [DOI: 10.1016/j.bios.2013.02.045] [Citation(s) in RCA: 172] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2013] [Revised: 02/27/2013] [Accepted: 02/28/2013] [Indexed: 12/21/2022]
44
Shen Q, Gong L, Baibado JT, Dong W, Wang Y, Dai Z, Cheung HY. Graphene based pipette tip solid phase extraction of marine toxins in shellfish muscle followed by UPLC-MS/MS analysis. Talanta 2013;116:770-5. [PMID: 24148472 DOI: 10.1016/j.talanta.2013.07.042] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2013] [Revised: 07/17/2013] [Accepted: 07/21/2013] [Indexed: 11/15/2022]
45
Hayat A, Andreescu S, Marty JL. Design of PEG-aptamer two piece macromolecules as convenient and integrated sensing platform: application to the label free detection of small size molecules. Biosens Bioelectron 2013;45:168-73. [PMID: 23500359 DOI: 10.1016/j.bios.2013.01.059] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2012] [Revised: 01/10/2013] [Accepted: 01/21/2013] [Indexed: 10/27/2022]
46
Bouden S, Chaussé A, Dorbes S, El Tall O, Bellakhal N, Dachraoui M, Vautrin-Ul C. Trace lead analysis based on carbon-screen-printed-electrodes modified via 4-carboxy-phenyl diazonium salt electroreduction. Talanta 2013;106:414-21. [PMID: 23598146 DOI: 10.1016/j.talanta.2013.01.021] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2012] [Revised: 01/06/2013] [Accepted: 01/11/2013] [Indexed: 10/27/2022]
47
Sassolas A, Hayat A, Catanante G, Marty JL. Detection of the marine toxin okadaic acid: Assessing seafood safety. Talanta 2013;105:306-16. [DOI: 10.1016/j.talanta.2012.10.049] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2012] [Revised: 10/10/2012] [Accepted: 10/13/2012] [Indexed: 10/27/2022]
48
Kanso H, Barthelmebs L, Inguimbert N, Noguer T. Immunosensors for Estradiol and Ethinylestradiol Based on New Synthetic Estrogen Derivatives: Application to Wastewater Analysis. Anal Chem 2013;85:2397-404. [DOI: 10.1021/ac303406c] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
49
Hayat A, Haider W, Rolland M, Marty JL. Electrochemical grafting of long spacer arms of hexamethyldiamine on a screen printed carbon electrode surface: application in target induced ochratoxin A electrochemical aptasensor. Analyst 2013;138:2951-7. [DOI: 10.1039/c3an00158j] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
50
Eissa S, Zourob M. A graphene-based electrochemical competitive immunosensor for the sensitive detection of okadaic acid in shellfish. NANOSCALE 2012;4:7593-7599. [PMID: 23108911 DOI: 10.1039/c2nr32146g] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
PrevPage 1 of 2 12Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA