1
|
S K, Illanad G, Saket S, Ghosh C. Recent advances in solid phase microextraction with various geometries in environmental analysis. RSC Adv 2024; 14:27608-27621. [PMID: 39221126 PMCID: PMC11363066 DOI: 10.1039/d4ra03251a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Accepted: 08/23/2024] [Indexed: 09/04/2024] Open
Abstract
Solid phase microextraction (SPME) has emerged as a versatile sample preparation technique for the preconcentration of a broad range of compounds with various polarities, especially in environmental studies. SPME has demonstrated its eco-friendly credentials, significantly reducing the reliance on solvents. The use of biocompatible materials as a coating recipe facilitates the acceptance of SPME devices in analytical chemistry, primarily in the monitoring of environmental pollutants such as persistent organic pollutants (POPs), volatile organic compounds (VOCs), and pesticides from the various environmental matrices. During the last few years, investigators have reported an improvement in the SPME enrichment technique after changing the coating recipe, geometries, and sampling procedure from the complex matrices. Furthermore, the development of various geometries of SPME with large surface areas has enhanced the extraction efficiency of environmental pollutants. As a miniaturized sample preparation technique, SPME significantly reduces the solvent usage, suggesting a potential platform for green chemistry-based research for water, air, and soil analysis. This review article summarizes the evolution of SPME, its various modes, the application of SPME, recent innovations, and prospects for the determination of water, air, and soil pollution. The advantages and disadvantages of SPME in comparison to other extraction techniques have been discussed here. This review serves as a valuable resource for investigators working in sustainable environmental research.
Collapse
Affiliation(s)
- Keerthana S
- Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal Karnataka 576104 India
| | - Gouri Illanad
- Department of Biotechnology, KLE Technological University Hubballi Karnataka 580021 India
| | - Swikriti Saket
- Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal Karnataka 576104 India
| | - Chiranjit Ghosh
- Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal Karnataka 576104 India
- Harvard Medical School 25 Shattuck Street Boston 02115 MA USA
| |
Collapse
|
2
|
Lee Y, Choi Y, Sim J, Kim J, Lim SH. Metal-organic framework-based high-performance column chip for micro gas chromatography: hybrid function for simultaneous preconcentration and separation of volatile organic compounds. LAB ON A CHIP 2023. [PMID: 38116799 DOI: 10.1039/d3lc00777d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2023]
Abstract
Numerous attempts have been made to replace commercial bulky gas chromatography (GC) systems with compact GC systems for monitoring volatile organic compounds in indoor air. However, recently developed compact GC systems are still too bulky in terms of user convenience, portability, and on-site analysis. Hence, an advanced miniaturization of compact GC systems is needed. Importantly, the small and high-performance gas pretreatment chip devices should be developed for compact GC systems. This paper reports the development of a metal-organic framework (MOF)-coated hybrid micro gas chromatography column chip (hybrid GC chip) capable of preconcentration and separation on harmful volatile organic compounds at low-concentration in one single chip device. The hybrid GC chip, 2 cm × 2 cm in size, was fabricated using a microelectromechanical systems process. The synthesized MOF-5 particles were coated on the inner wall of the fabricated hybrid GC chip and acted as an adsorbent and a stationary phase. The developed hybrid GC chip afforded high preconcentration factors with 1033-1237 and high separation resolutions with 3.8-13.3. The developed column showed good performance as a gas preconcentrator and separation column, and is the first device to perform both roles in one single chip device.
Collapse
Affiliation(s)
- Yeongseok Lee
- Department of Mechanical Systems, Kookmin University, Seoul 02707, Republic of Korea.
| | - Yuntaek Choi
- Department of Mechanical Systems, Kookmin University, Seoul 02707, Republic of Korea.
| | - Jaehyun Sim
- Department of Mechanical Systems, Kookmin University, Seoul 02707, Republic of Korea.
| | - Jeonghun Kim
- Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul 03722, Republic of Korea.
| | - Si-Hyung Lim
- School of Mechanical Engineering, Kookmin University, Seoul 02707, Republic of Korea.
| |
Collapse
|
3
|
Yan X, Qu H, Chang Y, Duan X. Application of Metal-Organic Frameworks in Gas Pre-concentration, Pre-separation and Detection. ACTA CHIMICA SINICA 2022. [DOI: 10.6023/a22030134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
4
|
A MEMS µ-Preconcentrator Employing a Carbon Molecular Sieve Membrane for Highly Volatile Organic Compound Sampling. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9050104] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This paper presents the synthesis and evaluation of a carbon molecular sieve membrane (CMSM) grown inside a MEMS-fabricated μ-preconcentrator for sampling highly volatile organic compounds. An array of µ-pillars measuring 100 µm in diameter and 250 µm in height were fabricated inside a microfluidic channel to increase the attaching surface for the CMSM. The surface area of the CMSM was measured as high as 899 m2/g. A GC peak amplification factor >2 × 104 was demonstrated with gaseous ethyl acetate. Up to 1.4 L of gaseous ethanol at the 100 ppb level could be concentrated without exceeding the capacity of this microchip device. Sharp desorption chromatographic peaks (<3.5 s) were obtained while using this device directly as a GC injector. Less volatile compounds such as gaseous toluene, m-xylene, and mesitylene appeared to be adsorbed strongly on CMSM, showing a memory effect. Sampling parameters such as sample volatilities, sampling capacities, and compound residual issues were empirically determined and discussed.
Collapse
|
5
|
Kalidoss R, Umapathy S. An overview on the exponential growth of non-invasive diagnosis of diabetes mellitus from exhaled breath by nanostructured metal oxide Chemi-resistive gas sensors and μ-preconcentrator. Biomed Microdevices 2019; 22:2. [PMID: 31797133 DOI: 10.1007/s10544-019-0448-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The characterization of acetone in exhaled breath reflects the internal metabolism of glucose in bloodstream and airways. This phenomenon provides a great potential for non-invasive diagnosis of diabetes mellitus and has inspired medical sodalities as an alternative diagnostic tool. This review discusses about the origination of acetone in breath, its correlation with blood glucose level along with the ways to collect breath sample. Furthermore, we also discuss the detection of acetone by chemical sensors with emphasis on the use of pre-concentrators on a single lab-on-chip for the diagnosis of diabetes mellitus. Finally, this review outlines the future directions for the detection of acetone from exhaled breath. The first part of the review introduces the biochemistry and prevalence of diabetes in India along with the existing techniques to estimate the concentration of acetone. The second part focuses on the semiconducting metal oxide and polymer gas sensors which discusses about tailoring the dynamic sensitivity range and selectivity towards acetone in breath. The third part elaborates on the ways to pre-concentrate the target biomarkers along with future perspectives for non-invasive diabetes diagnosis. Finally we also provide the perspectives on future challenges to make it to clinical practice. Graphical abstract .
Collapse
Affiliation(s)
- Ramji Kalidoss
- Department of Biomedical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, 603203, India
| | - Snekhalatha Umapathy
- Department of Biomedical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, 603203, India.
| |
Collapse
|
6
|
A carbon nanotube sponge as an adsorbent for vapor preconcentration of aromatic volatile organic compounds. J Chromatogr A 2019; 1605:460363. [DOI: 10.1016/j.chroma.2019.460363] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Revised: 06/17/2019] [Accepted: 07/09/2019] [Indexed: 11/20/2022]
|
7
|
A Binder Jet Printed, Stainless Steel Preconcentrator as an In-Line Injector of Volatile Organic Compounds. SENSORS 2019; 19:s19122748. [PMID: 31248098 PMCID: PMC6630219 DOI: 10.3390/s19122748] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/05/2019] [Revised: 06/11/2019] [Accepted: 06/17/2019] [Indexed: 11/17/2022]
Abstract
A conventional approach to making miniature or microscale gas chromatography (GC) components relies on silicon as a base material and MEMS fabrication as manufacturing processes. However, these devices often fail in medium-to-high temperature applications due to a lack of robust fluidic interconnects and a high-yield bonding process. This paper explores the feasibility of using metal additive manufacturing (AM), which is also known as metal 3D printing, as an alternative platform to produce small-scale microfluidic devices that can operate at a temperature higher than that which polymers can withstand. Binder jet printing (BJP), one of the metal AM processes, was utilized to make stainless steel (SS) preconcentrators (PCs) with submillimeter internal features. PCs can increase the concentration of gaseous analytes or serve as an inline injector for GC or gas sensor applications. Normally, parts printed by BJP are highly porous and thus often infiltrated with low melting point metal. By adding to SS316 powder sintering additives such as boron nitride (BN), which reduces the liquidus line temperature, we produce near full-density SS PCs at sintering temperatures much lower than the SS melting temperature, and importantly without any measurable shape distortion. Conversely, the SS PC without BN remains porous after the sintering process and unsuitable for fluidic applications. Since the SS parts, unlike Si, are compatible with machining, they can be modified to work with commercial compression fitting. The PC structures as well as the connection with the fitting are leak-free with relatively high operating pressures. A flexible membrane heater along with a resistance-temperature detector is integrated with the SS PCs for thermal desorption. The proof-of-concept experiment demonstrates that the SS PC can preconcentrate and inject 0.6% headspace toluene to enhance the detector's response.
Collapse
|
8
|
Płotka-Wasylka J, Szczepańska N, Owczarek K, Namieśnik J. Miniaturized Solid Phase Extraction. COMPREHENSIVE ANALYTICAL CHEMISTRY 2017. [DOI: 10.1016/bs.coac.2017.03.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
9
|
Płotka-Wasylka J, Szczepańska N, de la Guardia M, Namieśnik J. Miniaturized solid-phase extraction techniques. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.04.026] [Citation(s) in RCA: 309] [Impact Index Per Article: 34.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
10
|
Bryant-Genevier J, Zellers ET. Toward a microfabricated preconcentrator-focuser for a wearable micro-scale gas chromatograph. J Chromatogr A 2015; 1422:299-309. [DOI: 10.1016/j.chroma.2015.10.045] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2015] [Revised: 10/14/2015] [Accepted: 10/14/2015] [Indexed: 10/22/2022]
|
11
|
Haghighi F, Talebpour Z, Sanati-Nezhad A. Through the years with on-a-chip gas chromatography: a review. LAB ON A CHIP 2015; 15:2559-2575. [PMID: 25994317 DOI: 10.1039/c5lc00283d] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
In recent years, the need for measurement and detection of samples in situ or with very small volume and low concentration (low and sub-parts per billion) is a cause for miniaturizing systems via microelectromechanical system (MEMS) technology. Gas chromatography (GC) is a common technique that is widely used for separating and measuring semi-volatile and volatile compounds. Conventional GCs are bulky and cannot be used for in situ analysis, hence in the past decades many studies have been reported with the aim of designing and developing chip-based GC. The focus of this review is to follow and investigate the development and the achievements in the field of chip-based GC and its components from the beginning up to the present.
Collapse
Affiliation(s)
- F Haghighi
- Chromatographic and Separation Laboratory, Department of Chemistry, Faculty of Physics and Chemistry, Alzahra University, Vanak, Tehran, Iran.
| | | | | |
Collapse
|
12
|
Li Z, Ma R, Bai S, Wang C, Wang Z. A solid phase microextraction fiber coated with graphene–poly(ethylene glycol) composite for the extraction of volatile aromatic compounds from water samples. Talanta 2014; 119:498-504. [DOI: 10.1016/j.talanta.2013.11.068] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2013] [Revised: 11/19/2013] [Accepted: 11/24/2013] [Indexed: 11/25/2022]
|
13
|
Konvalina G, Haick H. Sensors for breath testing: from nanomaterials to comprehensive disease detection. Acc Chem Res 2014; 47:66-76. [PMID: 23926883 DOI: 10.1021/ar400070m] [Citation(s) in RCA: 253] [Impact Index Per Article: 25.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
The analysis of volatile organic compounds in exhaled breath samples represents a new frontier in medical diagnostics because it is a noninvasive and potentially inexpensive way to detect illnesses. Clinical trials with spectrometry and spectroscopy techniques, the standard volatile-compound detection methods, have shown the potential for diagnosing illnesses including cancer, multiple sclerosis, Parkinson's disease, tuberculosis, diabetes, and more via breath tests. Unfortunately, this approach requires expensive equipment and high levels of expertise to operate the necessary instruments, and the tests must be done quickly and use preconcentration techniques, all of which impede its adoption. Sensing matrices based on nanomaterials are likely to become a clinical and laboratory diagnostic tool because they are significantly smaller, easier-to-use, and less expensive than spectrometry or spectroscopy. An ideal nanomaterial-based sensor for breath testing should be sensitive at very low concentrations of volatile organic compounds, even in the presence of environmental or physiological confounding factors. It should also respond rapidly and proportionately to small changes in concentration and provide a consistent output that is specific to a given volatile organic compound. When not in contact with the volatile organic compounds, the sensor should quickly return to its baseline state or be simple and inexpensive enough to be disposable. Several reviews have focused on the methodological, biochemical, and clinical aspects of breath analysis in attempts to bring breath testing closer to practice for comprehensive disease detection. This Account pays particular attention to the technological gaps and confounding factors that impede nanomaterial-sensor-based breath testing, in the hope of directing future research and development efforts towards the best possible approaches to overcome these obstacles. We discuss breath testing as a complex process involving numerous steps, each of which has several possible technological alternatives with advantages and drawbacks that might affect the performance of the nanomaterial-based sensors in a breath-testing system. With this in mind, we discuss how to choose nanomaterial-based sensors, considering the profile of the targeted breath markers and the possible limitations of the approach, and how to design the surrounding breath-testing setup. We also discuss how to tailor the dynamic range and selectivity of the applied sensors to detect the disease-related volatile organic compounds of interest. Finally, we describe approaches to overcome other obstacles by improving the sensing elements and the supporting techniques such as preconcentration and dehumidification.
Collapse
Affiliation(s)
- Gady Konvalina
- The Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion − Israel Institute of Technology, Haifa 3200003, Israel
| | - Hossam Haick
- The Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion − Israel Institute of Technology, Haifa 3200003, Israel
| |
Collapse
|
14
|
Haick H, Broza YY, Mochalski P, Ruzsanyi V, Amann A. Assessment, origin, and implementation of breath volatile cancer markers. Chem Soc Rev 2013; 43:1423-49. [PMID: 24305596 DOI: 10.1039/c3cs60329f] [Citation(s) in RCA: 358] [Impact Index Per Article: 32.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
A new non-invasive and potentially inexpensive frontier in the diagnosis of cancer relies on the detection of volatile organic compounds (VOCs) in exhaled breath samples. Breath can be sampled and analyzed in real-time, leading to fascinating and cost-effective clinical diagnostic procedures. Nevertheless, breath analysis is a very young field of research and faces challenges, mainly because the biochemical mechanisms behind the cancer-related VOCs are largely unknown. In this review, we present a list of 115 validated cancer-related VOCs published in the literature during the past decade, and classify them with respect to their "fat-to-blood" and "blood-to-air" partition coefficients. These partition coefficients provide an estimation of the relative concentrations of VOCs in alveolar breath, in blood and in the fat compartments of the human body. Additionally, we try to clarify controversial issues concerning possible experimental malpractice in the field, and propose ways to translate the basic science results as well as the mechanistic understanding to tools (sensors) that could serve as point-of-care diagnostics of cancer. We end this review with a conclusion and a future perspective.
Collapse
Affiliation(s)
- Hossam Haick
- The Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion - Israel Institute of Technology, Haifa 3200003, Israel.
| | | | | | | | | |
Collapse
|