1
|
Grabarczyk M, Wawruch A. Screen-Printed Carbon Electrode Modified with Carbon Nanotubes and Copper Film as a Simple Tool for Determination of Trace Concentrations of Lead Ions. MEMBRANES 2024; 14:53. [PMID: 38392680 PMCID: PMC10890294 DOI: 10.3390/membranes14020053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 01/27/2024] [Accepted: 02/05/2024] [Indexed: 02/24/2024]
Abstract
A copper film-modified, carboxyl-functionalized, and multi-walled carbon nanotube (MWCNT-COOH)-modified screen-printed carbon electrode (CuF/MWCNTs/SPCE) was used for lead determination using anodic stripping voltammetry. The main parameters were investigated and optimized during the development of the research procedure. The most optimal electrolyte concentrations were determined to be 0.4 M HCl and 6.3 × 10-5 M Cu(II). The optimal parameters for voltammetric stripping measurements are as follows: an accumulation potential of -0.7 V; an accumulation time of 120 s; and a pulse amplitude and pulse time of 120 mV and 2 ms, respectively. The effect of surface active substances and humic substances as potential interferents present in aqueous environmental samples was investigated. The validation of the procedure was carried out using certified reference materials, like waste water SPS-WW1 and environmental matrix TM-25.5. In addition, the developed procedure was applied to investigate lead recovery from natural environmental water, such as rivers and lakes.
Collapse
Affiliation(s)
- Malgorzata Grabarczyk
- Department of Analytical Chemistry, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, 20-031 Lublin, Poland
| | - Agnieszka Wawruch
- Department of Analytical Chemistry, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, 20-031 Lublin, Poland
| |
Collapse
|
2
|
Redhwan TZ, Ali Y, Howlader MMR, Haddara YM. Electrochemical Sensing of Lead in Drinking Water Using Copper Foil Bonded with Polymer. SENSORS (BASEL, SWITZERLAND) 2023; 23:1424. [PMID: 36772462 PMCID: PMC9920348 DOI: 10.3390/s23031424] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 01/24/2023] [Accepted: 01/26/2023] [Indexed: 06/18/2023]
Abstract
Levels of lead (Pb) in tap water that are well below established guidelines are now considered harmful, so the detection of sub-parts-per-billion (ppb) Pb levels is crucial. In this work, we developed a two-step, facile, and inexpensive fabrication approach that involves direct bonding of copper (Cu) and liquid crystal polymer (LCP) followed by polyester resin printing for masking onto Cu/LCP to fabricate Cu thin-film-based Pb sensors. The oxygen plasma-treated surfaces resulted in strongly bonded Cu/LCP with a high peel strength of 500 N/m due to the highly hydrophilic nature of both surfaces. The bonded specimen can withstand wet etching of the electrode and can address delamination of the electrode for prolonged use in application environments. The Cu-foil-based electrochemical sensor showed sensitivity of ~11 nA/ppb/cm2 and a limit of detection (LOD) of 0.2 ppb (0.2 µg/L) Pb ions in water. The sensor required only 30 s and a 100 µL sample to detect Pb. To date, this is the most rapid detection of Pb performed using an all-Cu-based sensor. The selectivity test of Cu to Pb with interferences from cadmium and zinc showed that their peaks were separated by a few hundred millivolts. This approach has strong potential towards realizing low-cost, highly reliable integrated water quality monitoring systems.
Collapse
|
3
|
K. S. MK, Nagaraju DH, Yhobu Z, H. N. NK, Budagumpi S, Kumar Bose S, P. S, Palakollu VN. Tuning the Surface Functionality of Fe 3O 4 for Sensitive and Selective Detection of Heavy Metal Ions. SENSORS (BASEL, SWITZERLAND) 2022; 22:8895. [PMID: 36433488 PMCID: PMC9695242 DOI: 10.3390/s22228895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 11/08/2022] [Accepted: 11/14/2022] [Indexed: 06/16/2023]
Abstract
The functionalization of materials for ultrasensitive detection of heavy metal ions (HMIs) in the environment is crucial. Herewith, we have functionalized inexpensive and environmentally friendly Fe3O4 nanoparticles with D-valine (Fe3O4-D-Val) by a simple co-precipitation synthetic approach characterized by XRD, FE-SEM, and FTIR spectroscopy. The Fe3O4-D-Val sensor was used for the ultrasensitive detection of Cd+2, Pb+2, and Cu+2 in water samples. This sensor shows a very low detection limit of 11.29, 4.59, and 20.07 nM for Cd+2, Pb+2, and Cu+2, respectively. The detection limits are much lower than the values suggested by the world health Organization. The real water samples were also analyzed using the developed sensor.
Collapse
Affiliation(s)
| | - D. H. Nagaraju
- School of Applied Science, REVA University, Bengaluru 560064, India
| | - Zhoveta Yhobu
- Center for Nano and Material Sciences, Jain University, Jain Global Campus, Kanakapura, Ramanagaram, Bangalore 562112, India
| | - Nayan Kumar H. N.
- Center for Nano and Material Sciences, Jain University, Jain Global Campus, Kanakapura, Ramanagaram, Bangalore 562112, India
| | - Srinivasa Budagumpi
- Center for Nano and Material Sciences, Jain University, Jain Global Campus, Kanakapura, Ramanagaram, Bangalore 562112, India
| | - Shubhankar Kumar Bose
- Center for Nano and Material Sciences, Jain University, Jain Global Campus, Kanakapura, Ramanagaram, Bangalore 562112, India
| | - Shivakumar P.
- School of Applied Science, REVA University, Bengaluru 560064, India
| | | |
Collapse
|
4
|
Kim C, Park J, Kim W, Lee W, Na S, Park J. Detection of Cd 2+ and Pb 2+ using amyloid oligomer-reduced graphene oxide composite. Bioelectrochemistry 2022; 147:108214. [PMID: 35901626 DOI: 10.1016/j.bioelechem.2022.108214] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 07/18/2022] [Accepted: 07/19/2022] [Indexed: 11/02/2022]
Abstract
Heavy metal ions are toxic to humans and can further interact with amyloid in the human body to produce amyloid plaques, which disrupt neurotransmitter function and are linked to Alzheimer's and Parkinson's diseases. In this study, we developed an amyloid oligomer-reduced graphene oxide composite (AOrGOC) electrochemical sensor for effective heavy metal ion detection based on square-wave anodic stripping voltammetry. The reactivity between amyloids and heavy metal ions was studied by analyzing the stripping current for different amyloids (lysozyme, bovine serum albumin, and β-lactoglobulin) and amyloid growth types (monomers, oligomers, and fibrils). Reduced graphene oxide was used to improve the sensitivity of the sensor. The AOrGOC sensor exhibited the detection limits of 86.0 and 9.5 nM for Cd2+ and Pb2+, respectively, and selectively detected Cd2+ and Pb2+ over other heavy metal ions. The AOrGOC sensor also detected Cd2+ and Pb2+ in human plasma, thus exhibiting its potential as a biosensor. This study not only promoted our fundamental understanding of amyloids and the detection of heavy metal ions using amyloids, but also provided valuable insights into amyloid-based electrochemical sensors.
Collapse
Affiliation(s)
- Chihyun Kim
- Department of Biomechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 16419, South Korea
| | - Joohyung Park
- Department of Biomechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 16419, South Korea
| | - Woochang Kim
- Department of Biomechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 16419, South Korea
| | - Wonseok Lee
- Department of Electrical Engineering, Korea National University of Transportation, Chungju 27469, South Korea.
| | - Sungsoo Na
- Department of Mechanical Engineering, Korea University, Seoul 02841, South Korea.
| | - Jinsung Park
- Department of Biomechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 16419, South Korea.
| |
Collapse
|
5
|
Patle A, Kurrey R, Deb MK, Patle TK, Sinha D, Shrivas K. Analytical approaches on some selected toxic heavy metals in the environment and their socio-environmental impacts: A meticulous review. J INDIAN CHEM SOC 2022. [DOI: 10.1016/j.jics.2022.100545] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
6
|
Shellaiah M, Sun KW. Diamond-Based Electrodes for Detection of Metal Ions and Anions. NANOMATERIALS 2021; 12:nano12010064. [PMID: 35010014 PMCID: PMC8746347 DOI: 10.3390/nano12010064] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2021] [Revised: 12/14/2021] [Accepted: 12/22/2021] [Indexed: 02/07/2023]
Abstract
Diamond electrodes have long been a well-known candidate in electrochemical analyte detection. Nano- and micro-level modifications on the diamond electrodes can lead to diverse analytical applications. Doping of crystalline diamond allows the fabrication of suitable electrodes towards specific analyte monitoring. In particular, boron-doped diamond (BDD) electrodes have been reported for metal ions, anions, biomolecules, drugs, beverage hazards, pesticides, organic molecules, dyes, growth stimulant, etc., with exceptional performance in discriminations. Therefore, numerous reviews on the diamond electrode-based sensory utilities towards the specified analyte quantifications were published by many researchers. However, reviews on the nanodiamond-based electrodes for metal ions and anions are still not readily available nowadays. To advance the development of diamond electrodes towards the detection of diverse metal ions and anions, it is essential to provide clear and focused information on the diamond electrode synthesis, structure, and electrical properties. This review provides indispensable information on the diamond-based electrodes towards the determination of metal ions and anions.
Collapse
|
7
|
Morris A, Serrano N, Díaz-Cruz JM, Bendavid A, Chen M, Vepsäläinen M. Vibrating boron-doped diamond electrode: A new, durable and highly sensitive tool for the detection of cadmium. Anal Chim Acta 2021; 1188:339166. [PMID: 34794577 DOI: 10.1016/j.aca.2021.339166] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 09/16/2021] [Accepted: 10/09/2021] [Indexed: 12/31/2022]
Abstract
In this paper, a vibrating boron-doped diamond (BDD) electrode electroanalytical device and respective method for the analysis of ultralow concentrations of Cd(II) in water were studied. The enhanced mass transfer on the electrode surface was studied using Ru(NH3)6Cl3. Vibration with 133 Hz frequency enhanced the Ru(III) to Ru(II) reduction by 92.6% compared to a static electrode. The peak current of the anodic stripping voltammetry (ASV) method employed was increased by a factor of 5.3 and 4.7 for 10 and 30 μg L-1 Cd(II) concentrations, respectively, when a frequency of 200 Hz was used. A calibration plot with two linear regions was resolved between 0.01 and 1 μg L-1 and 1-30 μg L-1 with the LOD and LOQ of 0.04 μg L-1 and 0.12 μg L-1, respectively. The applicability of the device and the respective method in the analysis of real environmental samples was successfully verified by analysis of river samples and comparing the results with the ICP analysis presenting high reproducibility and trueness. According to the results of this research, the vibrating BDD electrode with the ASV method has excellent analytical performance without surface modification or regular replacement or polishing of the electrode surface. Combining the exceptional electrochemical and chemical properties of BDD with enhanced mass transfer and signal strength of vibrating electrodes makes the system especially suitable for on-site and online analysis of heavy metals.
Collapse
Affiliation(s)
- Adam Morris
- CSIRO, Mineral Resources, Private Bag 10, Clayton South, Victoria, 3169, Australia
| | - Núria Serrano
- Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Martí i Franquès 1-11, 08028, Barcelona, Spain.
| | - José Manuel Díaz-Cruz
- Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Martí i Franquès 1-11, 08028, Barcelona, Spain
| | - Avi Bendavid
- CSIRO Manufacturing, 36 Bradfield Road, Lindfield, New South Wales, 2070, Australia; School of Materials Science and Engineering, University of New South Wales (UNSW, Sydney), Sydney, NSW, 2052, Australia
| | - Miao Chen
- CSIRO, Mineral Resources, Private Bag 10, Clayton South, Victoria, 3169, Australia
| | - Mikko Vepsäläinen
- CSIRO, Mineral Resources, Private Bag 10, Clayton South, Victoria, 3169, Australia; VTT Technical Research Centre of Finland, P.O. Box 1000, FI-02044, VTT, Finland.
| |
Collapse
|
8
|
Pei J, Yu X, Wei S, Boukherroub R, Zhang Y. Double-side effect of B/C ratio on BDD electrode detection for heavy metal ion in water. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 771:145430. [PMID: 33736132 DOI: 10.1016/j.scitotenv.2021.145430] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 01/05/2021] [Accepted: 01/22/2021] [Indexed: 06/12/2023]
Abstract
BDD (Boron-doped Diamond) electrode may hold a promising application to detect heavy metal ions for actual water monitoring and early warning, but a poor understanding of influence mechanism of B/C ratio on detection performance is in the way of its fabrication and application. This work is intended to reveal the double-side effect of B/C ratio on detection performance of BDD electrode so as to facilitate its actual application. SBDD (Self-supported Boron-doped Diamond) electrode is introduced for the first time to get rid of the interference factors such as substrate. A systematic investigation is conducted for the influence of B/C ratio on microstructure and electrochemical behavior of SBDD electrodes. With the increase of B/C ratio, the grain size continuously increases, and the preferred orientation gradually changes from plane (220) to (111). The gradual increasing of impurity phase content indicates a deterioration of diamond phase quality. In addition, the electrode electrochemical behavior initially gets better then worse. SBDD electrode with a B/C ratio of 1/500 has the largest active surface area of 2.1 cm2, the smallest diffusion resistance and the highest signal response. Under optimal parameter set, the SBDD electrode enjoys a sensitivity of 0.42 μA L μg-1 cm-2 and a detection limit of 1.12 μg L-1 in a wide linear range of 5-120 ppb. The phase quality and grain morphology jointly contribute to the double-side effect. A suitable B-sp3-C content, preferred orientation of (111) and small particle size may make the performance improvement of BDD electrode available.
Collapse
Affiliation(s)
- Jingxuan Pei
- Beijing Key Laboratory of Materials Utilisation of Nonmetallic Minerals and Solid Wastes, National Laboratory of Mineral Materials, School of Materials Science and Technology, China University of Geosciences (Beijing), 29 Xueyuan Road, Haidian, Beijing 100083, China
| | - Xiang Yu
- Beijing Key Laboratory of Materials Utilisation of Nonmetallic Minerals and Solid Wastes, National Laboratory of Mineral Materials, School of Materials Science and Technology, China University of Geosciences (Beijing), 29 Xueyuan Road, Haidian, Beijing 100083, China.
| | - Songbo Wei
- PetroChina Research Institute of Petroleum Exploration and Development, 20 Xueyuan Road, Haidian, Beijing 100083, China
| | - Rabah Boukherroub
- Univ. Lille, CNRS, Centrale Lille, ISEN, Univ. Valenciennes, UMR 8520, IEMN, F-59000, Lille, France
| | - Yihe Zhang
- Beijing Key Laboratory of Materials Utilisation of Nonmetallic Minerals and Solid Wastes, National Laboratory of Mineral Materials, School of Materials Science and Technology, China University of Geosciences (Beijing), 29 Xueyuan Road, Haidian, Beijing 100083, China.
| |
Collapse
|
9
|
Poly(1,5-Diaminonaphthalene)-Modified Screen-Printed Device for Electrochemical Lead Ion Sensing. ADVANCES IN POLYMER TECHNOLOGY 2021. [DOI: 10.1155/2021/6637316] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Poly(1,5-diaminonaphthalene) has been electropolymerized on the screen-printed device with a three-electrode configuration. The modified electrodes have been developed as the new electrode for electrochemical determination of trace levels of lead ions (Pb2+). The poly(1,5-diaminonaphthalene) film prevents the deposition of Pb2+ into the surface defects of the bare carbon screen-printed electrode and possesses sensitivity to heavy metal ions thanks to amine and secondary amino groups on the polymer chain. The square wave anodic stripping voltammetry was applied to detect Pb2+ ions, showing a sharp stripping peak with the linear range from 0.5 μg·L-1 to 5.0 μg·L-1 (
). The limit of detection was found to be 0.30 μg·L-1. The sensors were applied to the analysis of Pb2+ in the tap water sample matrix with satisfactory results.
Collapse
|
10
|
Physicochemical and Mechanical Performance of Freestanding Boron-Doped Diamond Nanosheets Coated with C:H:N:O Plasma Polymer. MATERIALS 2020; 13:ma13081861. [PMID: 32326555 PMCID: PMC7215835 DOI: 10.3390/ma13081861] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/07/2020] [Revised: 04/09/2020] [Accepted: 04/13/2020] [Indexed: 01/22/2023]
Abstract
The physicochemical and mechanical properties of thin and freestanding heavy boron-doped diamond (BDD) nanosheets coated with a thin C:H:N:O plasma polymer were studied. First, diamond nanosheets were grown and doped with boron on a Ta substrate using the microwave plasma-enhanced chemical vapor deposition technique (MPECVD). Next, the BDD/Ta samples were covered with nylon 6.6 to improve their stability in harsh environments and flexibility during elastic deformations. Plasma polymer films with a thickness of the 500–1000 nm were obtained by magnetron sputtering of a bulk target of nylon 6.6. Hydrophilic nitrogen-rich C:H:N:O was prepared by the sputtering of nylon 6.6. C:H:N:O as a film with high surface energy improves adhesion in ambient conditions. The nylon–diamond interface was perfectly formed, and hence, the adhesion behavior could be attributed to the dissipation of viscoelastic energy originating from irreversible energy loss in soft polymer structure. Diamond surface heterogeneities have been shown to pin the contact edge, indicating that the retraction process causes instantaneous fluctuations on the surface in specified microscale regions. The observed Raman bands at 390, 275, and 220 cm−1 were weak; therefore, the obtained films exhibited a low level of nylon 6 polymerization and short-distance arrangement, indicating crystal symmetry and interchain interactions. The mechanical properties of the nylon-on-diamond were determined by a nanoindentation test in multiload mode. Increasing the maximum load during the nanoindentation test resulted in a decreased hardness of the fabricated structure. The integration of freestanding diamond nanosheets will make it possible to design flexible chemical multielectrode sensors.
Collapse
|
11
|
Maldonado VY, Espinoza-Montero PJ, Rusinek CA, Swain GM. Analysis of Ag(I) Biocide in Water Samples Using Anodic Stripping Voltammetry with a Boron-Doped Diamond Disk Electrode. Anal Chem 2018; 90:6477-6485. [DOI: 10.1021/acs.analchem.7b04983] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Vanessa Y. Maldonado
- Facultad de Ingeniería Química y Agroindustria, Escuela Politécnica Nacional, Ladrón de Guevara E11-253, P.O. Box 17-01-2759, Quito 170525, Ecuador
- Department of Chemistry, Michigan State University, East Lansing, Michigan 48824, United States
| | - Patricio J. Espinoza-Montero
- Escuela de Ciencias Químicas, Pontificia Universidad Católica del Ecuador, Avenida 12 de octubre y Roca,
P.O. Box 17-01-2184, Quito, Ecuador
- Departamento de Ingeniería Civil y Ambiental, Escuela Politécnica Nacional, Ladrón de Guevara E11-253, P.O. Box 17-01-2759, Quito, Ecuador
| | - Cory A. Rusinek
- Fraunhofer Center for Coatings and Diamond Technologies, Michigan State University, East Lansing, Michigan 48824 United States
| | - Greg M. Swain
- Department of Chemistry, Michigan State University, East Lansing, Michigan 48824, United States
| |
Collapse
|
12
|
|
13
|
Voltammetric determination of metal ions beyond mercury electrodes. A review. Anal Chim Acta 2017; 990:11-53. [DOI: 10.1016/j.aca.2017.07.069] [Citation(s) in RCA: 105] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2017] [Revised: 07/24/2017] [Accepted: 07/29/2017] [Indexed: 02/01/2023]
|
14
|
Perween M, Srivastava DN. A Cost-Effective, Unmodified Platform for the Detection of Heavy Metals via Anodic Stripping Voltammetry at Nanomolar Level. ChemistrySelect 2017. [DOI: 10.1002/slct.201700477] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
- Mosarrat Perween
- Analytical Division and Centralized Instrument Facility; CSIR-Central Salt & Marine Chemicals Research Institute, Gijubhai Badheka Marg; Bhavnagar 364002 India
- Academy of Scientific and Innovative Research, Gijubhai Badheka Marg; Bhavnagar 364002 India
| | - Divesh N. Srivastava
- Analytical Division and Centralized Instrument Facility; CSIR-Central Salt & Marine Chemicals Research Institute, Gijubhai Badheka Marg; Bhavnagar 364002 India
- Academy of Scientific and Innovative Research, Gijubhai Badheka Marg; Bhavnagar 364002 India
| |
Collapse
|
15
|
Efficient Use of Porous Hybrid Materials in a Selective Detection of Lead(II) from Aqueous Solutions: An Electrochemical Study. METALS 2017. [DOI: 10.3390/met7040124] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
16
|
The Polypyrrole/Multiwalled Carbon Nanotube Modified Au Microelectrode for Sensitive Electrochemical Detection of Trace Levels of Pb2+. MICROMACHINES 2017. [PMCID: PMC6190322 DOI: 10.3390/mi8030086] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The sensitive detection of trace levels of heavy metal ions such as Pb2+ is of significant importance due to the health hazard they pose. In this paper, we present a polypyrrole (PPy)/multiwalled carbon nanotube (MWCNT)-modified Au microelectrode. The PPy/MWCNT composite film was electrochemically deposited on the microelectrode by cyclic voltammetry (CV). The composite film was investigated by scanning electron microscope (SEM), CV, and electrochemical impedance spectroscopy (EIS), and the results show that this film presents a uniformly distributed and web-like entangled structure and good conductivity. Differential pulse stripping voltammetry (DPSV) was applied to determine trace levels of Pb2+. Experimental conditions including accumulation time and deposition potential were optimized. In optimal conditions, the PPy/MWCNT-modified microelectrode performed sensitive detection of Pb2+ within a concentration range from 1 to 100 μg·L−1, and the limit of detection was 0.65 μg·L−1 at the signal-to-noise ratio of three.
Collapse
|
17
|
Pandey SK, Singh P, Singh J, Sachan S, Srivastava S, Singh SK. Nanocarbon-based Electrochemical Detection of Heavy Metals. ELECTROANAL 2016. [DOI: 10.1002/elan.201600173] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Shailendra Kumar Pandey
- Department of Chemical Engineering; Motilal Nehru National Institute of Technology Allahabad; Allahabad- 211004 India
| | - Priti Singh
- Department of Biotechnology; Motilal Nehru National Institute of Technology Allahabad; Allahabad- 211004 India
| | - Jyoti Singh
- Department of Biotechnology; Motilal Nehru National Institute of Technology Allahabad; Allahabad- 211004 India
| | - Sadhana Sachan
- Department of Chemical Engineering; Motilal Nehru National Institute of Technology Allahabad; Allahabad- 211004 India
| | - Sameer Srivastava
- Department of Biotechnology; Motilal Nehru National Institute of Technology Allahabad; Allahabad- 211004 India
| | - Sunil Kumar Singh
- Department of Biotechnology; Motilal Nehru National Institute of Technology Allahabad; Allahabad- 211004 India
| |
Collapse
|
18
|
Dossi C, Monticelli D, Pozzi A, Recchia S. Exploiting Chemistry to Improve Performance of Screen-Printed, Bismuth Film Electrodes (SP-BiFE). BIOSENSORS-BASEL 2016; 6:bios6030038. [PMID: 27455338 PMCID: PMC5039657 DOI: 10.3390/bios6030038] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/27/2016] [Revised: 07/05/2016] [Accepted: 07/15/2016] [Indexed: 11/25/2022]
Abstract
Mercury substitution is a big issue in electroanalysis, and the search for a suitable, and less toxic, replacement is still under development. Of all the proposed alternatives, bismuth films appear to be the most viable solution, although they are still suffering some drawbacks, particularly the influence of deposition conditions and linearity at low concentrations. In this paper, the most promising strategies for bismuth film deposition on screen-printed electrodes (surface modifications, polymeric film deposition, insoluble salt precursors) will be evaluated for trace metal analysis. Particular attention will be devoted to bismuth chemistry, aiming to rationalize their electroanalytic performance.
Collapse
Affiliation(s)
- Carlo Dossi
- Dipartimento di Scienze Teoriche e Applicate (DiSTA), University of Insubria, Via Dunant, 2, 21100 Varese, Italy.
| | - Damiano Monticelli
- Dipartimento di Scienza ed Alta Tecnologia (DiSAT), University of Insubria, Via Valleggio, 11, 22100 Como, Italy.
| | - Andrea Pozzi
- Dipartimento di Scienza ed Alta Tecnologia (DiSAT), University of Insubria, Via Valleggio, 11, 22100 Como, Italy.
| | - Sandro Recchia
- Dipartimento di Scienza ed Alta Tecnologia (DiSAT), University of Insubria, Via Valleggio, 11, 22100 Como, Italy.
| |
Collapse
|
19
|
Boron-doped diamond electrodes explored for the electroanalytical detection of 7-methylguanine and applied for its sensing within urine samples. Electrochim Acta 2016. [DOI: 10.1016/j.electacta.2015.11.026] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
20
|
Effects of dynamic polarization on boron-doped NCD properties and on its performance for electrochemical-analysis of Pb (II), Cu (II) and Hg (II) in aqueous solution via direct LSV. Sep Purif Technol 2015. [DOI: 10.1016/j.seppur.2015.07.022] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
21
|
YANAGISAWA H, KURITA R, KAMATA T, YOSHIOKA K, KATO D, IWASAWA A, NAKAZATO T, TORIMURA M, NIWA O. Effect of the sp 2/sp 3 Ratio in a Hybrid Nanocarbon Thin Film Electrode for Anodic Stripping Voltammetry Fabricated by Unbalanced Magnetron Sputtering Equipment. ANAL SCI 2015; 31:635-41. [DOI: 10.2116/analsci.31.635] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Hiroyuki YANAGISAWA
- National Institute of Advanced Industrial Science and Technology (AIST)
- Institute of Materials Science, Graduate School of Pure and Applied Sciences, University of Tsukuba
| | - Ryoji KURITA
- National Institute of Advanced Industrial Science and Technology (AIST)
| | - Tomoyuki KAMATA
- National Institute of Advanced Industrial Science and Technology (AIST)
| | - Kyoko YOSHIOKA
- National Institute of Advanced Industrial Science and Technology (AIST)
| | - Dai KATO
- National Institute of Advanced Industrial Science and Technology (AIST)
| | - Ayumi IWASAWA
- National Institute of Advanced Industrial Science and Technology (AIST)
| | - Tetsuya NAKAZATO
- National Institute of Advanced Industrial Science and Technology (AIST)
| | - Masaki TORIMURA
- National Institute of Advanced Industrial Science and Technology (AIST)
| | - Osamu NIWA
- National Institute of Advanced Industrial Science and Technology (AIST)
- Institute of Materials Science, Graduate School of Pure and Applied Sciences, University of Tsukuba
| |
Collapse
|