1
|
Aihaiti A, Wang J, Zhang W, Shen M, Meng F, Li Z, Zhang Y, Ren M, Zhang M. Recent advances and trends in innovative biosensor-based devices for heavy metal ion detection in food. Compr Rev Food Sci Food Saf 2024; 23:e13358. [PMID: 38923121 DOI: 10.1111/1541-4337.13358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 04/08/2024] [Accepted: 04/10/2024] [Indexed: 06/28/2024]
Abstract
Low-cost, reliable, and efficient biosensors are crucial in detecting residual heavy metal ions (HMIs) in food products. At present, based on distance-induced localized surface plasmon resonance of noble metal nanoparticles, enzyme-mimetic reaction of nanozymes, and chelation reaction of metal chelators, the constructed optical sensors have attracted wide attention in HMIs detection. Besides, based on the enrichment and signal amplification strategy of nanomaterials on HMIs and the construction of electrochemical aptamer sensing platforms, the developed electrochemical biosensors have overcome the plague of low sensitivity, poor selectivity, and the inability of multiplexed detection in the optical strategy. Moreover, along with an in-depth discussion of these different types of biosensors, a detailed overview of the design and application of innovative devices based on these sensing principles was provided, including microfluidic systems, hydrogel-based platforms, and test strip technologies. Finally, the challenges that hinder commercial application have also been mentioned. Overall, this review aims to establish a theoretical foundation for developing accurate and reliable sensing technologies and devices for HMIs, thereby promoting the widespread application of biosensors in the detection of HMIs in food.
Collapse
Affiliation(s)
- Aihemaitijiang Aihaiti
- Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, College of Life Science & Technology, Xinjiang University, Ürümqi, China
| | - Jingkang Wang
- Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, College of Life Science & Technology, Xinjiang University, Ürümqi, China
| | - Wenrui Zhang
- School of Chemistry, Dalian University of Technology, Dalian, Liaoning, China
| | - Mingping Shen
- Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, College of Life Science & Technology, Xinjiang University, Ürümqi, China
| | - Fanxing Meng
- Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, College of Life Science & Technology, Xinjiang University, Ürümqi, China
| | - Zongda Li
- Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, College of Life Science & Technology, Xinjiang University, Ürümqi, China
| | - Yukun Zhang
- Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, College of Life Science & Technology, Xinjiang University, Ürümqi, China
| | - Mengyao Ren
- Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, College of Life Science & Technology, Xinjiang University, Ürümqi, China
| | - Minwei Zhang
- Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, College of Life Science & Technology, Xinjiang University, Ürümqi, China
| |
Collapse
|
2
|
Chen Z, Zhang Z, Qi J, You J, Ma J, Chen L. Colorimetric detection of heavy metal ions with various chromogenic materials: Strategies and applications. JOURNAL OF HAZARDOUS MATERIALS 2023; 441:129889. [PMID: 36087533 DOI: 10.1016/j.jhazmat.2022.129889] [Citation(s) in RCA: 44] [Impact Index Per Article: 44.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 08/21/2022] [Accepted: 08/30/2022] [Indexed: 05/27/2023]
Abstract
Detection of heavy metal ions has drawn significant attention in environmental and food area due to their threats to the human health and ecosystem. Colorimetry is one of the most frequently-used methods for the detection of heavy metal ions owing to its simplicity, easy operation and rapid on-site detection. The development of chromogenic materials and their sensing mechanisms are the key research direction in the area of colorimetric method. Since each chromogenic material has their unique optical and chemical properties, they have totally different colorimetric sensing mechanisms. This review focuses on the chromogenic materials and their sensing strategies for the colorimetric detection of heavy metal ions. We divide the chromogenic materials into three types, including organic materials, inorganic materials, and other materials. As for each type of chromogenic material, we discuss their detailed sensing strategies, sensing performance, and real sample applications. Moreover, current challenges and perspectives related to the colorimetry of heavy metal ions are also discussed in this review. The aim of this review is to help readers to better understand the principles of colorimetric methods for heavy metal ions and push the development of rapid detection of heavy metal ions.
Collapse
Affiliation(s)
- Zhuo Chen
- Key Laboratory of Life-Organic Analysis of Shandong Province, School of Chemistry and Chemical Engineering, Qufu Normal University, Qufu 273165, PR China; CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China
| | - Zhiyang Zhang
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China; Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao 264003, China.
| | - Ji Qi
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China; Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao 264003, China
| | - Jinmao You
- Key Laboratory of Life-Organic Analysis of Shandong Province, School of Chemistry and Chemical Engineering, Qufu Normal University, Qufu 273165, PR China; College of Chemistry and Chemical Engineering, Shaoxing University, Shaoxing 312000, China.
| | - Jiping Ma
- School of Environmental & Municipal Engineering, Qingdao University of Technology, Qingdao 266033, China
| | - Lingxin Chen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China; Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao 264003, China; School of Pharmacy, Binzhou Medical University, Yantai 264003, China.
| |
Collapse
|
3
|
Kaewjua K, Nakthong P, Chailapakul O, Siangproh W. Flow-based System: A Highly Efficient Tool Speeds Up Data Production and Improves Analytical Performance. ANAL SCI 2021; 37:79-92. [PMID: 32981899 DOI: 10.2116/analsci.20sar02] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
In this review, we cite references from the period between 2015 and 2020 related to the use of a flow-based system as a tool to obtain a modern analytical system for speeding up data production and improving performance. Based on a great deal of concepts for automatic systems, there are several research groups introduced in the development of flow-based systems to increase sample throughput while retaining the reproducibility and repeatability as well as to propose new platforms of flow-based systems, such as microfluidic chip and paper-based devices. Additionally, to apply a developed system for on-site analysis is one of the key features for development. We believe that this review will be very interested and useful for readers because of its impact on developing novel analytical systems. The content of the review is categorized following their applications including quality control and food safety, clinical diagnostics, environmental monitoring and miscellaneous.
Collapse
Affiliation(s)
- Kantima Kaewjua
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand
| | - Prangthip Nakthong
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand
| | - Orawon Chailapakul
- Electrochemistry and Optical Spectroscopy Center of Excellence, Department of Chemistry, Faculty of Science, Bangkok, 10330, Thailand
| | - Weena Siangproh
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand.
| |
Collapse
|
4
|
Du F, Cheng Z, Kremer M, Liu Y, Wang X, Shuang S, Dong C. A label-free multifunctional nanosensor based on N-doped carbon nanodots for vitamin B 12 and Co 2+ detection, and bioimaging in living cells and zebrafish. J Mater Chem B 2020; 8:5089-5095. [PMID: 32406457 DOI: 10.1039/d0tb00443j] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Multifunctional N-doped carbon nanodots (N-CNDs) with a fluorescence (FL) quantum yield (QY) of 13.6% have been synthesized via a facile one-step hydrothermal process using Artemisia annua and 1,2-ethylenediamine as precursors. As-prepared N-CNDs showed excellent FL properties and were developed as a multifunctional sensing platform for vitamin B12 (VB12) and Co2+ determination, and bioimaging in living cells and zebrafish. The FL of N-CNDs is quenched efficiently in the presence of VB12 on the basis of the inner filter effect (IFE) or Co2+ by static quenching, respectively. EDTA as a masking agent enables Co2+ to be effectively eliminated and N-CNDs were used to selectively detect VB12 in the presence of both VB12 and Co2+. The present FL nanosensor can detect VB12 and Co2+ in the linear ranges of 0.5-35 μM and 2.5-25 μM with the corresponding detection limits of 47.4 nM and 230.5 nM, respectively. The study proved that the determination of Co2+ was based on the static quenching to form a complex between the amino group of N-CNDs and Co2+. Inspired by these outstanding properties, practical applications of this nanosensor for the detection of VB12 in actual samples (human serum, egg yolk, VB12 tablets and VB12 injection) and Co2+ in water samples were further verified with satisfactory results. The as-constructed N-CNDs have negligible toxicity and good biocompatibility, which facilitates utilization of N-CNDs in bioimaging of A549 cells and zebrafish, and sensing VB12 in living cells.
Collapse
Affiliation(s)
- Fangfang Du
- Institute of Environmental Science, and School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan 030006, China.
| | | | | | | | | | | | | |
Collapse
|
5
|
Tekin Z, Unutkan T, Erulaş F, Bakırdere EG, Bakırdere S. A green, accurate and sensitive analytical method based on vortex assisted deep eutectic solvent-liquid phase microextraction for the determination of cobalt by slotted quartz tube flame atomic absorption spectrometry. Food Chem 2020; 310:125825. [DOI: 10.1016/j.foodchem.2019.125825] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Revised: 10/18/2019] [Accepted: 10/28/2019] [Indexed: 12/20/2022]
|
6
|
Chen M, Dong X, Yao L, Song Z, Zhu L. Sensitive spectrophotometric determination of trace-level Co2+ in water based on acetate enhanced catalysis of Co2+. Microchem J 2019. [DOI: 10.1016/j.microc.2019.01.026] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
7
|
da Silva Magalhães T, Reis BF. A Sensitive Photometric Procedure for Cobalt Determination in Water Employing a Compact Multicommuted Flow Analysis System. APPLIED SPECTROSCOPY 2017; 71:2154-2163. [PMID: 28593792 DOI: 10.1177/0003702817713749] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
In this work, a multicommuted flow analysis procedure is proposed for the spectrophotometric determination of cobalt in fresh water, employing an instrument setup of downsized dimension and improved cost-effectiveness. The method is based on the catalytic effect of Co(II) on the Tiron oxidation by hydrogen peroxide in alkaline medium, forming a complex that absorbs radiation at 425 nm. The photometric detection was accomplished using a homemade light-emitting-diode (LED)-based photometer designed to use a flow cell with an optical path-length of 100 mm to improve sensitivity. After selecting adequate values for the flow system variables, adherence to the Beer-Lambert-Bouguer law was observed for standard solution concentrations in the range of 0.13-1.5 µg L-1 Co(II). Other useful features including a relative standard deviation of 2.0% (n = 11) for a sample with 0.49 µg L-1 Co(II), a detection limit of 0.06 µg L-1 Co(II) (n = 20), an analytical frequency of 42 sample determinations per hour, and waste generation of 1.5 mL per determination were achieved.
Collapse
Affiliation(s)
| | - Boaventura F Reis
- 2 Centro de Energia Nuclear na Agricultura, Universidade de São Paulo, Piracicaba, SP, Brasil
| |
Collapse
|
8
|
Cerdà V, González A, Danchana K. From thermometric to spectrophotometric kinetic-catalytic methods of analysis. A review. Talanta 2017; 167:733-746. [DOI: 10.1016/j.talanta.2017.02.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2016] [Revised: 01/31/2017] [Accepted: 02/01/2017] [Indexed: 11/27/2022]
|
9
|
Abouhiat F, Henríquez C, El Yousfi F, Cerdà V. Sensitive kinetic-catalytic spectrophotometric method for cobalt determination using a chip coupled to a multisyringe flow injection analysis system. Talanta 2017; 166:405-411. [DOI: 10.1016/j.talanta.2015.12.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2015] [Revised: 11/28/2015] [Accepted: 12/08/2015] [Indexed: 11/28/2022]
|
10
|
|
11
|
Abstract
A dynamic development of methodologies of analytical flow injection measurements during four decades since their invention has reinforced the solid position of flow analysis in the arsenal of techniques and instrumentation of contemporary chemical analysis.
Collapse
Affiliation(s)
- Marek Trojanowicz
- Laboratory of Nuclear Analytical Methods
- Institute of Nuclear Chemistry and Technology
- 03-195 Warsaw
- Poland
- Department of Chemistry
| | - Kamila Kołacińska
- Laboratory of Nuclear Analytical Methods
- Institute of Nuclear Chemistry and Technology
- 03-195 Warsaw
- Poland
| |
Collapse
|
12
|
Khoddami N, Shemirani F. A new magnetic ion-imprinted polymer as a highly selective sorbent for determination of cobalt in biological and environmental samples. Talanta 2016; 146:244-52. [DOI: 10.1016/j.talanta.2015.08.046] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2015] [Revised: 08/21/2015] [Accepted: 08/23/2015] [Indexed: 10/23/2022]
|