1
|
Nyabadza A, McCarthy É, Makhesana M, Heidarinassab S, Plouze A, Vazquez M, Brabazon D. A review of physical, chemical and biological synthesis methods of bimetallic nanoparticles and applications in sensing, water treatment, biomedicine, catalysis and hydrogen storage. Adv Colloid Interface Sci 2023; 321:103010. [PMID: 37804661 DOI: 10.1016/j.cis.2023.103010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 08/30/2023] [Accepted: 09/24/2023] [Indexed: 10/09/2023]
Abstract
This article provides an in-depth analysis of various fabrication methods of bimetallic nanoparticles (BNP), including chemical, biological, and physical techniques. The review explores BNP's diverse uses, from well-known applications such as sensing water treatment and biomedical uses to less-studied areas like breath sensing for diabetes monitoring and hydrogen storage. It cites results from over 1000 researchers worldwide and >300 peer-reviewed articles. Additionally, the article discusses current trends, actionable recommendations, and the importance of synthetic analysis for industry players looking to optimize manufacturing techniques for specific applications. The article also evaluates the pros and cons of various fabrication methods, highlighting the potential of plant extract synthesis for mass production of capped BNPs. However, it warns that this method may not be suitable for certain applications requiring ligand-free surfaces. In contrast, physical methods like laser ablation offer better control and reactivity, especially for applications where ligand-free surfaces are critical. The report underscores the environmental benefits of plant extract synthesis compared to chemical methods that use hazardous chemicals and pose risks to extraction, production, and disposal. The article emphasizes the need for life cycle assessment (LCA) articles in the literature, given the growing volume of research on nanotechnology materials. This article caters to researchers at all stages and applies to various fields applying nanomaterials.
Collapse
Affiliation(s)
- Anesu Nyabadza
- I-Form Advanced Manufacturing Centre Research, Dublin City University, Glasnevin, Dublin 9, Ireland; EPSRC & SFI Centre for Doctoral Training (CDT) in Advanced Metallic Systems, School of Mechanical & Manufacturing Engineering, School of Chemical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland; Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9, Ireland.
| | - Éanna McCarthy
- I-Form Advanced Manufacturing Centre Research, Dublin City University, Glasnevin, Dublin 9, Ireland; Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Mayur Makhesana
- Mechanical Engineering Department, Institute of Technology, Nirma University, Ahmedabad, Gujarat 382481, India
| | - Saeid Heidarinassab
- I-Form Advanced Manufacturing Centre Research, Dublin City University, Glasnevin, Dublin 9, Ireland; EPSRC & SFI Centre for Doctoral Training (CDT) in Advanced Metallic Systems, School of Mechanical & Manufacturing Engineering, School of Chemical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland; Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Anouk Plouze
- Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9, Ireland; Conservatoire National des arts et Métiers (CNAM), 61 Rue du Landy, 93210 Saint-Denis, France
| | - Mercedes Vazquez
- I-Form Advanced Manufacturing Centre Research, Dublin City University, Glasnevin, Dublin 9, Ireland; EPSRC & SFI Centre for Doctoral Training (CDT) in Advanced Metallic Systems, School of Mechanical & Manufacturing Engineering, School of Chemical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland; Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Dermot Brabazon
- I-Form Advanced Manufacturing Centre Research, Dublin City University, Glasnevin, Dublin 9, Ireland; EPSRC & SFI Centre for Doctoral Training (CDT) in Advanced Metallic Systems, School of Mechanical & Manufacturing Engineering, School of Chemical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland; Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9, Ireland
| |
Collapse
|
2
|
Green Carbon Dots: Applications in Development of Electrochemical Sensors, Assessment of Toxicity as Well as Anticancer Properties. Catalysts 2023. [DOI: 10.3390/catal13030537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/10/2023] Open
Abstract
Carbon dots are one of the most promising nanomaterials which exhibit a wide range of applications in the field of bioimaging, sensing and biomedicine due to their ultra-small size, high photostability, tunable fluorescence, electrical properties, etc. However, green carbon dots synthesized from several natural and renewable sources show some additional advantages, such as favorable biocompatibility, wide sources, low cost of production and ecofriendly nature. In this review, we will provide an update on the latest research of green carbon dots regarding their applications in cancer therapy and in the development of electrochemical sensors. Besides, the toxicity assessment of carbon dots as well as the challenges and future direction of research on their anticancer and sensing applications will be discussed.
Collapse
|
3
|
Mohammadi M, Khosravi S, Nili-Ahmadabadi A, Kamalabadi M, Ghasemzadeh-Mohammadi V, Afkhami A. Rapid determination of ampyra in urine samples using dispersive liquid-liquid microextraction coupled with ion mobility spectrometry. J Pharm Biomed Anal 2023; 224:115185. [PMID: 36516725 DOI: 10.1016/j.jpba.2022.115185] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 11/22/2022] [Accepted: 11/23/2022] [Indexed: 12/03/2022]
Abstract
Ampyra (AMP, 4-Aminopyridine) is a potassium channel blocker that attracts growing research interest due to its adverse effects at high doses. The fast analysis of AMP is challenging because it typically requires complex analytical techniques. In this research, we developed and validated a novel method to assess the fast and quantitative analysis of AMP from real samples. This method combines the strength of ion mobility spectrometry (IMS) for rapid detection and the dispersive liquid-liquid microextraction as a fast and effective preconcentration method for the preconcentration/extraction of AMP. In this method, Ag nanoparticles were used as modifier agents. Moreover, the proposed mechanism for interaction of AMP with AgNPs was investigated based on the quantum theory of atoms in molecules (QTAIM) analysis. Also, the sensitivity of the proposed method was improved through the application of a delay on the carrier gas flow after sample injection. Under the optimum conditions, the developed method detected AMP in the linear range of 0.4-16 μmol L-1 with a detection limit of 0.12 µmol L-1. Finally, the developed method was successfully employed to quantify AMP in urine samples. Method validation was performed by comparing our results with those obtained by HPLC-UV/Vis, confirming the applicability of the proposed method for the AMP analysis in real samples. The proposed method will open up a new door toward developing simple, fast, and effective analytical methods.
Collapse
Affiliation(s)
- Mojdeh Mohammadi
- Department of Pharmacology and Toxicology, School of Pharmacy, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Sara Khosravi
- Department of Pharmacology and Toxicology, School of Pharmacy, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Amir Nili-Ahmadabadi
- Department of Pharmacology and Toxicology, School of Pharmacy, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Mahdie Kamalabadi
- Department of Pharmacology and Toxicology, School of Pharmacy, Hamadan University of Medical Sciences, Hamadan, Iran.
| | | | - Abbas Afkhami
- Faculty of Chemistry, Bu-Ali Sina University, Hamadan, Iran
| |
Collapse
|
4
|
Selective and sensitive electrochemical detection of doxorubicin via a novel magnesium oxide/carbon dot nanocomposite based sensor. INORG CHEM COMMUN 2023. [DOI: 10.1016/j.inoche.2023.110527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
|
5
|
Parvin S, Hashemi P, Afkhami A, Ghanei M, Bagheri H. Simultaneous determination of BoNT/A and /E using an electrochemical sandwich immunoassay based on the nanomagnetic immunosensing platform. CHEMOSPHERE 2022; 298:134358. [PMID: 35307386 DOI: 10.1016/j.chemosphere.2022.134358] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 02/24/2022] [Accepted: 03/16/2022] [Indexed: 06/14/2023]
Abstract
Developing new ultrasensitive assays for the detection of the presence, and determination of the serotype of the most poisonous material known i.e. botulinum neurotoxin (BoNT) is vital to human health and the wellbeing of the surrounding environment. Here, an electrochemical sandwich immunoassay with high sensitivity is adopted to achieve simultaneous determination of BoNT serotypes A and E based on polystyrene@polydopamine/Cd2+ and Ag nanoparticles acting as monoclonal antibody labels. Two well-separated peaks with strong electrochemical signals are generated by the labels, allowing for the simultaneous detection of two analytes existing on the electrode. To obtain well-oriented polyclonal antibodies immobilization, boronic acid is directly attached to the magnetic core/metal-organic framework (MOF) shell nanoagent surfaces without the requirement of a long and flexible spacer. Accordingly, it is possible to directly detect the metal ion labels through square wave voltammetry without the metal pre-concentration step. This results in distinct and well-defined voltammetric peaks, pertaining to each sandwich-type immunocomplexes. The limits of detection of BoNT/A and BoNT/E analyses were found to be 0.04 and 0.16 pg mL-1 with the linear dynamic ranges of 0.1-1000 and 0.5-1000 pg mL-1, respectively. Based on the obtained results, this immunosensor has the wide linear ranges, while also exhibiting low limits of detection along with good stability and reproducibility.
Collapse
Affiliation(s)
- Shahram Parvin
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Pegah Hashemi
- Research and Development Department, Farin Behbood Tashkhis LTD, Tehran, Iran
| | - Abbas Afkhami
- Faculty of Chemistry, Bu-Ali Sina University, Hamedan, Iran
| | - Mostafa Ghanei
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Hasan Bagheri
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
6
|
A portable solid-state electrochemical sensor based on N-doped graphite as a transducer layer for determination of a multiple sclerosis managing medication in biological fluids. J Solid State Electrochem 2022. [DOI: 10.1007/s10008-022-05123-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
7
|
Kaya SI, Cetinkaya A, Ozkan SA. Carbon Nanomaterial-Based Drug Sensing Platforms Using State-of-the-
Art Electroanalytical Techniques. CURR ANAL CHEM 2022. [DOI: 10.2174/1573411016999200802024629] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
Currently, nanotechnology and nanomaterials are considered as the most popular and outstanding
research subjects in scientific fields ranging from environmental studies to drug analysis. Carbon nanomaterials such as
carbon nanotubes, graphene, carbon nanofibers etc. and non-carbon nanomaterials such as quantum dots, metal
nanoparticles, nanorods etc. are widely used in electrochemical drug analysis for sensor development. Main aim of drug
analysis with sensors is developing fast, easy to use and sensitive methods. Electroanalytical techniques such as
voltammetry, potentiometry, amperometry etc. which measure electrical parameters such as current or potential in an
electrochemical cell are considered economical, highly sensitive and versatile techniques.
Methods:
Most recent researches and studies about electrochemical analysis of drugs with carbon-based nanomaterials were
analyzed. Books and review articles about this topic were reviewed.
Results:
The most significant carbon-based nanomaterials and electroanalytical techniques were explained in detail. In
addition to this; recent applications of electrochemical techniques with carbon nanomaterials in drug analysis was expressed
comprehensively. Recent researches about electrochemical applications of carbon-based nanomaterials in drug sensing were
given in a table.
Conclusion:
Nanotechnology provides opportunities to create functional materials, devices and systems using
nanomaterials with advantageous features such as high surface area, improved electrode kinetics and higher catalytic
activity. Electrochemistry is widely used in drug analysis for pharmaceutical and medical purposes. Carbon nanomaterials
based electrochemical sensors are one of the most preferred methods for drug analysis with high sensitivity, low cost and
rapid detection.
Collapse
Affiliation(s)
- S. Irem Kaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560, Ankara,Turkey
| | - Ahmet Cetinkaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560, Ankara,Turkey
| | - Sibel A. Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560, Ankara,Turkey
| |
Collapse
|
8
|
Fayed AS, Ayish NS, El-Zeany BA, Marzouk HM. Novel dalfampridine-selective green potentiometric membrane sensors for in-line dissolution profiling of its extended release tablets. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
9
|
Mollarasouli F, Zor E, Ozcelikay G, Ozkan SA. Magnetic nanoparticles in developing electrochemical sensors for pharmaceutical and biomedical applications. Talanta 2021; 226:122108. [PMID: 33676664 DOI: 10.1016/j.talanta.2021.122108] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 12/14/2020] [Accepted: 01/06/2021] [Indexed: 02/06/2023]
Abstract
A revolutionary impact on the pharmaceutical and biomedical applications has been arisen in the few years to come as a result of the advances made in magnetic nanoparticles (MNPs) research. The use of MNPs opens wide opportunities in diagnostics, drug and gene delivery, in vivo imaging, magnetic separation, and hyperthermia therapy, etc. Besides, their possible integration in sensors makes them an ideal essential element of innovative pharmaceutical and biomedical applications. Nowadays, MNPs-based electrochemical sensors have attracted great attention to pharmaceutical and biomedical applications owing to their high sensitivity, stability. Selectivity towards the target as well as their simplicity of manufacture. Therefore, this review focus on recent advances with cutting-edge approaches dealing with the synthesis, design, and advantageous analytical performance of MNPs in the electrochemical sensors utilized for pharmaceutical and biomedical applications between 2015 and 2020. The challenges existing in this research area and some potential strategies/future perspectives for the rational design of electrochemical sensors are also outlined.
Collapse
Affiliation(s)
| | - Erhan Zor
- Department of Science Education, A. K. Education Faculty, Necmettin Erbakan University, Konya, 42090, Turkey; Biomaterials and Biotechnology Laboratory, Science and Technology Research and Application Center (BITAM), Necmettin Erbakan University, Konya, 42090, Turkey
| | - Goksu Ozcelikay
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560, Ankara, Turkey
| | - Sibel A Ozkan
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560, Ankara, Turkey.
| |
Collapse
|
10
|
Ahmadi M, Ghoorchian A, Dashtian K, Kamalabadi M, Madrakian T, Afkhami A. Application of magnetic nanomaterials in electroanalytical methods: A review. Talanta 2020; 225:121974. [PMID: 33592722 DOI: 10.1016/j.talanta.2020.121974] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Revised: 11/07/2020] [Accepted: 12/03/2020] [Indexed: 02/08/2023]
Abstract
Magnetic nanomaterials (MNMs) have gained high attention in different fields of studies due to their ferromagnetic/superparamagnetic properties and their low toxicity and high biocompatibility. MNMs contain magnetic elements such as iron and nickel in metallic, bimetallic, metal oxide, and mixed metal oxide. In electroanalytical methods, MNMs have been applied as sorbents for sample preparation before the electrochemical detection (sorbent role), as the electrode modifier (catalytic role), and the integration of the above two roles (as both sorbent and catalytic agent). In this paper, the application of MNMs in electroanalytical methods have been classified based on the main role of the nanomaterial and discussed separately. Furthermore, catalytic activities of MNMs in electroanalytical methods such as redox electrocatalytic, nanozymes catalytic (peroxidase, catalase activity, oxidase activity, superoxide dismutase activity), catalyst gate, and nanocontainer have been discussed.
Collapse
Affiliation(s)
- Mazaher Ahmadi
- Faculty of Chemistry, Bu-Ali Sina University, Hamedan, Iran.
| | | | | | | | | | - Abbas Afkhami
- Faculty of Chemistry, Bu-Ali Sina University, Hamedan, Iran.
| |
Collapse
|
11
|
Stanković V, Đurđić S, Ognjanović M, Mutić J, Kalcher K, Stanković DM. A novel nonenzymatic hydrogen peroxide amperometric sensor based on AgNp@GNR nanocomposites modified screen-printed carbon electrode. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114487] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
12
|
Sainz R, Del Pozo M, Vilas-Varela M, Castro-Esteban J, Pérez Corral M, Vázquez L, Blanco E, Peña D, Martín-Gago JA, Ellis GJ, Petit-Domínguez MD, Quintana C, Casero E. Chemically synthesized chevron-like graphene nanoribbons for electrochemical sensors development: determination of epinephrine. Sci Rep 2020; 10:14614. [PMID: 32884078 PMCID: PMC7471882 DOI: 10.1038/s41598-020-71554-1] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Accepted: 08/18/2020] [Indexed: 11/09/2022] Open
Abstract
We employ chevron-like graphene nanoribbons (GNRs) synthesized by a solution-based chemical route to develop a novel electrochemical sensor for determination of the neurotransmitter epinephrine (EPI). The sensor surface, a glassy carbon electrode modified with GNRs, is characterized by atomic force microscopy, scanning electron microscopy and Raman spectroscopy, which show that the electrode surface modification comprises of bi-dimensional multilayer-stacked GNRs that retain their molecular structure. The charge transfer process occurring at the electrode interface is evaluated by electrochemical impedance spectroscopy. The sensor is applied to the determination of EPI, employing as an analytical signal the reduction peak corresponding to the epinephrinechrome–leucoepinephrinechrome transition (E = − 0.25 V) instead of the oxidation peak usually employed in the literature (E = + 0.6 V) in order to minimize interferences. The results obtained demonstrate that chevron-like nanoribbons synthesized by solution methods exhibit reliable electrocatalytic activity for EPI determination. Using differential pulse voltammetry, we obtain a linear concentration range from 6.4 × 10–6 to 1.0 × 10–4 M and a detection limit of 2.1 × 10–6 M. The applicability of the sensor was evaluated by determining EPI in pharmaceutical samples with satisfactory results.
Collapse
Affiliation(s)
- Raquel Sainz
- Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Campus de Excelencia de la Universidad Autónoma de Madrid, c/ Francisco Tomás y Valiente, Nº7, 28049, Madrid, Spain
| | - María Del Pozo
- Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Campus de Excelencia de la Universidad Autónoma de Madrid, c/ Francisco Tomás y Valiente, Nº7, 28049, Madrid, Spain
| | - Manuel Vilas-Varela
- Centro Singular de Investigación en Química Biolóxica e Materiais Moleculares (CIQUS) and Departamento de Química Orgánica, Universidade de Santiago de Compostela, 15782, Santiago de Compostela, Spain
| | - Jesús Castro-Esteban
- Centro Singular de Investigación en Química Biolóxica e Materiais Moleculares (CIQUS) and Departamento de Química Orgánica, Universidade de Santiago de Compostela, 15782, Santiago de Compostela, Spain
| | - María Pérez Corral
- Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Campus de Excelencia de la Universidad Autónoma de Madrid, c/ Francisco Tomás y Valiente, Nº7, 28049, Madrid, Spain
| | - Luis Vázquez
- ESISNA group, Instituto de Ciencia de Materiales de Madrid (ICMM-CSIC), c/ Sor Juana Inés de la Cruz Nº3, 28049, Madrid, Spain
| | - Elías Blanco
- Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Campus de Excelencia de la Universidad Autónoma de Madrid, c/ Francisco Tomás y Valiente, Nº7, 28049, Madrid, Spain
| | - Diego Peña
- Centro Singular de Investigación en Química Biolóxica e Materiais Moleculares (CIQUS) and Departamento de Química Orgánica, Universidade de Santiago de Compostela, 15782, Santiago de Compostela, Spain
| | - José A Martín-Gago
- ESISNA group, Instituto de Ciencia de Materiales de Madrid (ICMM-CSIC), c/ Sor Juana Inés de la Cruz Nº3, 28049, Madrid, Spain
| | - Gary J Ellis
- Departamento de Física de Polímeros, Elastómeros y Aplicaciones Energéticas, Instituto de Ciencia y Tecnología de Polímeros (ICTP-CSIC), c/ Juan de la Cierva, 3, 28006, Madrid, Spain
| | - María Dolores Petit-Domínguez
- Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Campus de Excelencia de la Universidad Autónoma de Madrid, c/ Francisco Tomás y Valiente, Nº7, 28049, Madrid, Spain
| | - Carmen Quintana
- Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Campus de Excelencia de la Universidad Autónoma de Madrid, c/ Francisco Tomás y Valiente, Nº7, 28049, Madrid, Spain
| | - Elena Casero
- Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Campus de Excelencia de la Universidad Autónoma de Madrid, c/ Francisco Tomás y Valiente, Nº7, 28049, Madrid, Spain.
| |
Collapse
|
13
|
Hashemi P, Afkhami A, Baradaran B, Halabian R, Madrakian T, Arduini F, Nguyen TA, Bagheri H. Well-Orientation Strategy for Direct Immobilization of Antibodies: Development of the Immunosensor Using the Boronic Acid-Modified Magnetic Graphene Nanoribbons for Ultrasensitive Detection of Lymphoma Cancer Cells. Anal Chem 2020; 92:11405-11412. [PMID: 32687322 DOI: 10.1021/acs.analchem.0c02357] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
This work presents an effective strategy for the well-oriented immobilization of antibodies in which boronic acid is directly attached to the surface and with no need of the long and flexible spacer. A magnetic graphene nanoribbon-boronic-acid-based immunosensor was developed and tested for the impedimetric detection of lymphoma cancer cells, a blood cancer biomarker. Magnetic graphene nanoribbons (MGNRs) were modified with boronic acid (BA) to create a supporting matrix that is utilized by immobilizing anti-CD20 antibodies with good orientation. The prepared biosensing layer (MGNR/BA/Ab) with well-oriented antibodies was premixed into whole blood samples to interact with lymphoma cancer cell receptors. In the presence of target cell receptors, an immunocomplex was formed between anti-CD20 antibodies and lymphoma cancer cell receptors. Then, the biosensing layer was magnetically collected on a screen-printed carbon electrode (SPCE) and placed in a homemade electrochemical cell configuration to measure impedimetric signals. The fabrication steps of the immunosensor were characterized by various techniques, such as resonance light scattering, fluorescence, electrochemical impedance spectroscopy, and cyclic voltammetry. The assay is highly sensitive: the calculated limit of detection of lymphoma cancer cells was as low as 38 cells/mL, and the detection was linear from 100 to 1 000 000 cells/mL. The specificity of the immunosensor is also very high, and there is no interference effect with several potential interferents, such as the breast cancer (MCF-7), human embryonic kidney (HEK293), and leukemia (HL-60 and KCL-22) cell lines. The performance of the immunosensor for lymphoma cancer cells in clinical blood samples is consistent with that of commercial flow cytometric assays.
Collapse
Affiliation(s)
- Pegah Hashemi
- Faculty of Chemistry, Bu-Ali Sina University, Hamedan, Iran
| | - Abbas Afkhami
- Faculty of Chemistry, Bu-Ali Sina University, Hamedan, Iran
| | - Behzad Baradaran
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Raheleh Halabian
- Applied Microbiology Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | | | - Fabiana Arduini
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Via della Ricerca Scientifica, 00133, Rome, Italy
| | - Tien Anh Nguyen
- Department of Physics, Le Quy Don Technical University, Ha Noi, Viet Nam
| | - Hasan Bagheri
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| |
Collapse
|
14
|
Mathew AT, Akshaya KB, Vinod TP, Varghese A, George L. TEMPO‐Mediated Aqueous Phase Electrooxidation of Pyridyl Methanol at Palladium‐Decorated PANI on Carbon Fiber Paper Electrode. ChemistrySelect 2020. [DOI: 10.1002/slct.201904432] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Agnus T. Mathew
- Department of ChemistryCHRIST (Deemed to be University) Hosur Road Bengaluru 560029 India
| | - K. B. Akshaya
- Department of ChemistryCHRIST (Deemed to be University) Hosur Road Bengaluru 560029 India
| | - T. P. Vinod
- Department of ChemistryCHRIST (Deemed to be University) Hosur Road Bengaluru 560029 India
| | - Anitha Varghese
- Department of ChemistryCHRIST (Deemed to be University) Hosur Road Bengaluru 560029 India
| | - Louis George
- Department of ChemistryCHRIST (Deemed to be University) Hosur Road Bengaluru 560029 India
| |
Collapse
|
15
|
Rezvani Jalal N, Madrakian T, Afkhami A, Ghoorchian A. In Situ Growth of Metal-Organic Framework HKUST-1 on Graphene Oxide Nanoribbons with High Electrochemical Sensing Performance in Imatinib Determination. ACS APPLIED MATERIALS & INTERFACES 2020; 12:4859-4869. [PMID: 31908170 DOI: 10.1021/acsami.9b18097] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Metal-organic frameworks (MOFs) have been previously investigated as electrode materials for developing electrochemical sensors. They have usually been reported to suffer from poor conductivity and improvement in the conductivity of MOFs is still a great challenge. Here, we reported the fabrication of an electrochemical sensor based on the in situ growth of framework HKUST-1 on conductive graphene oxide nanoribbons (GONRs)-modified glassy carbon electrode (GCE) (HKUST-1/GONRs/GCE). The as-fabricated modified electrode was characterized using field emission scanning electron microscopy, transmission electron microscopy (TEM), high-resolution TEM, Fourier transform infrared, X-ray diffraction, electrochemical impedance spectroscopy, cyclic voltammetry, and Raman spectroscopy. The voltammetric response of HKUST-1/GONRs/GCE toward Imatinib (IMA), as an anticancer drug, is dramatically higher than HKUST-1/GCE because of the synergic effect of the GONRs and HKUST-1 framework. The calibration curve at the HKUST-1/GONRs/GCE for IMA covered two linear dynamic ranges, 0.04-1.0 and 1.0-80 μmol L-1, with a detection limit of 0.006 μmol L-1 (6 nmol L-1). Taking advantage of the conductivity of GONRs and large surface area of HKUST-1, a sensitive modified electrode was developed for the electrochemical determination of IMA. The present method provides an effective strategy to solve the poor conductivity of the MOFs. Finally, the obtained electrochemical performance made this modified electrode promising in the determination of IMA in urine and serum samples.
Collapse
Affiliation(s)
| | - Tayyebeh Madrakian
- Faculty of Chemistry , Bu-Ali Sina University , Hamedan 6517838695 , Iran
| | - Abbas Afkhami
- Faculty of Chemistry , Bu-Ali Sina University , Hamedan 6517838695 , Iran
| | - Arash Ghoorchian
- Faculty of Chemistry , Bu-Ali Sina University , Hamedan 6517838695 , Iran
| |
Collapse
|
16
|
Kholosi F, Afkhami A, Hashemi P, Madrakian T, Bagheri H. Bioelectrocatalysis and direct determination of H2O2 using the high-performance platform: chitosan nanofibers modified with SDS and hemoglobin. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2020. [DOI: 10.1007/s13738-020-01865-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
17
|
Li F, Huang Y, Huang K, Lin J, Huang P. Functional Magnetic Graphene Composites for Biosensing. Int J Mol Sci 2020; 21:E390. [PMID: 31936264 PMCID: PMC7013569 DOI: 10.3390/ijms21020390] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2019] [Revised: 12/13/2019] [Accepted: 12/26/2019] [Indexed: 12/14/2022] Open
Abstract
Magnetic graphene composites (MGCs), which are composed of magnetic nanoparticles with graphene or its derivatives, played an important role in sensors development. Due to the enhanced electronic properties and the synergistic effect of magnetic nanomaterials and graphene, MGCs could be used to realize more efficient sensors such as chemical, biological, and electronic sensors, compared to their single component alone. In this review, we first reviewed the various routes for MGCs preparation. Then, sensors based on MGCs were discussed in different groups, including optical sensors, electrochemical sensors, and others. At the end of the paper, the challenges and opportunities for MGCs in sensors implementation are also discussed.
Collapse
Affiliation(s)
| | | | | | | | - Peng Huang
- Marshall Laboratory of Biomedical Engineering, International Cancer Center, Laboratory of Evolutionary Theranostics (LET), School of Biomedical Engineering, Shenzhen University Health Science Center, Shenzhen 518060, China; (F.L.); (Y.H.); (K.H.); (J.L.)
| |
Collapse
|
18
|
Nouri M, Rahimnejad M, Najafpour G, Akbar Moghadamnia A. A Gr/αFe
2
O
3
/Carbon Paste Electrode Developed as an Electrochemical Sensor for Determination of Rizatriptan Benzoate: An Antimigraine Drug. ChemistrySelect 2019. [DOI: 10.1002/slct.201902845] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Affiliation(s)
- Maedeh Nouri
- Biofuel & Renewable Energy Research CenterDepartment of BiotechnologyFaculty of Chemical EngineeringBabol Noshirvani University of Technology, Babol, Mazandaran Iran
| | - Mostafa Rahimnejad
- Chemical Engineering DepartmentBabol Noshirvani University of Technology, Babol, Mazandaran Iran
| | - Ghasem Najafpour
- Biotechnology Research LaboratoryFaculty of Chemical EngineeringBabol Noshirvani University of Technology, Babol Iran
| | | |
Collapse
|
19
|
A modified screen printed electrode based on La3+-doped Co3O4 nanocubes for determination of sulfite in real samples. Microchem J 2019. [DOI: 10.1016/j.microc.2019.03.031] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
20
|
Mahmoudi E, Hajian A, Rezaei M, Afkhami A, Amine A, Bagheri H. A novel platform based on graphene nanoribbons/protein capped Au-Cu bimetallic nanoclusters: Application to the sensitive electrochemical determination of bisphenol A. Microchem J 2019. [DOI: 10.1016/j.microc.2018.10.044] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
21
|
|
22
|
Musa M, Wan Ibrahim WA, Mohd Marsin F, Abdul Keyon AS, Rashidi Nodeh H. Graphene-magnetite as adsorbent for magnetic solid phase extraction of 4-hydroxybenzoic acid and 3,4-dihydroxybenzoic acid in stingless bee honey. Food Chem 2018; 265:165-172. [DOI: 10.1016/j.foodchem.2018.04.020] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2017] [Revised: 04/05/2018] [Accepted: 04/09/2018] [Indexed: 10/17/2022]
|
23
|
Azevedo RD, Amaral IP, Ferreira AC, Espósito TS, Bezerra RS. Use of fish trypsin immobilized onto magnetic-chitosan composite as a new tool to detect antinutrients in aquafeeds. Food Chem 2018; 257:302-309. [DOI: 10.1016/j.foodchem.2018.03.034] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2017] [Revised: 03/08/2018] [Accepted: 03/08/2018] [Indexed: 10/17/2022]
|
24
|
Vukojević V, Djurdjić S, Ognjanović M, Fabián M, Samphao A, Kalcher K, Stanković DM. Enzymatic glucose biosensor based on manganese dioxide nanoparticles decorated on graphene nanoribbons. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2018.07.013] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
25
|
Kozitsina AN, Svalova TS, Malysheva NN, Okhokhonin AV, Vidrevich MB, Brainina KZ. Sensors Based on Bio and Biomimetic Receptors in Medical Diagnostic, Environment, and Food Analysis. BIOSENSORS 2018; 8:E35. [PMID: 29614784 PMCID: PMC6022999 DOI: 10.3390/bios8020035] [Citation(s) in RCA: 71] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Revised: 03/29/2018] [Accepted: 03/29/2018] [Indexed: 01/09/2023]
Abstract
Analytical chemistry is now developing mainly in two areas: automation and the creation of complexes that allow, on the one hand, for simultaneously analyzing a large number of samples without the participation of an operator, and on the other, the development of portable miniature devices for personalized medicine and the monitoring of a human habitat. The sensor devices, the great majority of which are biosensors and chemical sensors, perform the role of the latter. That last line is considered in the proposed review. Attention is paid to transducers, receptors, techniques of immobilization of the receptor layer on the transducer surface, processes of signal generation and detection, and methods for increasing sensitivity and accuracy. The features of sensors based on synthetic receptors and additional components (aptamers, molecular imprinted polymers, biomimetics) are discussed. Examples of bio- and chemical sensors' application are given. Miniaturization paths, new power supply means, and wearable and printed sensors are described. Progress in this area opens a revolutionary era in the development of methods of on-site and in-situ monitoring, that is, paving the way from the "test-tube to the smartphone".
Collapse
Affiliation(s)
- Alisa N Kozitsina
- Department of Analytical Chemistry, Institute of Chemical Engineering, Ural Federal University named after the first President of Russia B.N. Yeltsin, 620002 Yekaterinburg, Russia.
| | - Tatiana S Svalova
- Department of Analytical Chemistry, Institute of Chemical Engineering, Ural Federal University named after the first President of Russia B.N. Yeltsin, 620002 Yekaterinburg, Russia.
| | - Natalia N Malysheva
- Department of Analytical Chemistry, Institute of Chemical Engineering, Ural Federal University named after the first President of Russia B.N. Yeltsin, 620002 Yekaterinburg, Russia.
| | - Andrei V Okhokhonin
- Department of Analytical Chemistry, Institute of Chemical Engineering, Ural Federal University named after the first President of Russia B.N. Yeltsin, 620002 Yekaterinburg, Russia.
| | - Marina B Vidrevich
- Scientific and Innovation Center for Sensory Technologies, Ural State University of Economics, 620144 Yekaterinburg, Russia.
| | - Khiena Z Brainina
- Department of Analytical Chemistry, Institute of Chemical Engineering, Ural Federal University named after the first President of Russia B.N. Yeltsin, 620002 Yekaterinburg, Russia.
- Scientific and Innovation Center for Sensory Technologies, Ural State University of Economics, 620144 Yekaterinburg, Russia.
| |
Collapse
|
26
|
Fabrication of a novel aptasensor based on three-dimensional reduced graphene oxide/polyaniline/gold nanoparticle composite as a novel platform for high sensitive and specific cocaine detection. Anal Chim Acta 2017; 996:10-19. [DOI: 10.1016/j.aca.2017.10.035] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2017] [Accepted: 10/26/2017] [Indexed: 12/11/2022]
|