1
|
Sahragard A, Carrasco-Correa EJ, Cocovi-Solberg DJ, Kubáň P, Miró M. Enhancing the Concentration Capability of Nonsupported Electrically Driven Liquid-Phase Microextraction through Programmable Flow Using an All-In-One 3D-Printed Optosensor: A Proof of Concept. Anal Chem 2024; 96:11068-11075. [PMID: 38917332 PMCID: PMC11238157 DOI: 10.1021/acs.analchem.4c02139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/27/2024]
Abstract
A versatile millifluidic 3D-printed inverted Y-shaped unit (3D-YSU) was prototyped to ameliorate the concentration capability of nonsupported microelectromembrane extraction (μ-EME), exploiting optosensing detection for real-time monitoring of the enriched acceptor phase (AP). Continuous forward-flow and stop-and-go flow modes of the donor phase (DP) were implemented via an automatic programmable-flow system to disrupt the electrical double layer generated at the DP/organic phase (OP) interface while replenishing the potentially depleted layers of analyte in DP. To further improve the enrichment factor (EF), the organic holding section of the OP/AP channel was bifurcated to increase the interfacial contact area between the DP and the OP. Exploiting the synergistic assets of (i) the continuous forward-flow of DP (1050 μL), (ii) the unique 3D-printed cone-shaped pentagon cross-sectional geometry of the OP/AP channel, (iii) the bifurcation of the OP that creates an inverted Y-shape configuration, and (iv) the in situ optosensing of the AP, a ca. 24 EF was obtained for a 20 min extraction using methylene blue (MB) as a model analyte. The 3D-YSU was leveraged for the unsupervised μ-EME and the determination of MB in textile dye and urban wastewater samples, with relative recoveries ≥88%. This is the first work toward analyte preconcentration in μ-EME with in situ optosensing of the resulting extracts using 3D-printed millifluidic platforms.
Collapse
Affiliation(s)
- Ali Sahragard
- FI-TRACE Group, Department of Chemistry, Faculty of Science, University of the Balearic Islands, Carretera de Valldemossa km 7.5, E-07122 Palma de Mallorca, Illes Balears, Spain
| | - Enrique Javier Carrasco-Correa
- CLECEM Group, Department of Analytical Chemistry, University of Valencia, C/Doctor Moliner, 50, 46100 Burjassot, Valencia, Spain
| | - David J Cocovi-Solberg
- Department of Chemistry, Institute of Analytical Chemistry, University of Natural Resources and Life Sciences Vienna, Muthgasse 18, 1190 Vienna, Austria
| | - Pavel Kubáň
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200 Brno, Czech Republic
| | - Manuel Miró
- FI-TRACE Group, Department of Chemistry, Faculty of Science, University of the Balearic Islands, Carretera de Valldemossa km 7.5, E-07122 Palma de Mallorca, Illes Balears, Spain
| |
Collapse
|
2
|
Tahmasebi E, Javadi A. Introduction of an electrospun nanofibrous membrane incorporated by metal-organic framework-199 (MOF-199) with Lewis acid property for efficient extraction of sulfonamides in on-chip electromembrane extraction. J Chromatogr A 2024; 1723:464900. [PMID: 38643741 DOI: 10.1016/j.chroma.2024.464900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 03/24/2024] [Accepted: 04/09/2024] [Indexed: 04/23/2024]
Abstract
In this study, a new supporting polymeric membrane having Lewis acid nature was introduced for immobilizing organic solvent in on-chip electromembrane extraction (on-chip EME). For this aim, a polymeric nanofibrous membrane incorporated by a copper based metal-organic framework (MOF-199), with coordinatively unsaturated metal sites and Lewis acid property, was prepared by electrospinning a mixture of polycaprolactone (PCL) and MOF-199. Based on the field emission scanning electron microscopy images, the obtained polymeric membrane consisted of intertwined nanofibers having empty space between the fibers which could provide a suitable place for immobilizing the organic solvent. To demonstrate remarkable extractability of the proposed membrane (PCL/MOF-199 nanofibers) via executing Lewis acid-base interactions, three sulfonamide drugs was selected as anionic polar analytes with Lewis base feature. The parameters affecting the extraction efficiency of the method were optimized through the experimental design method using the orthogonal and rotatable central composite design (CCD). Under optimum conditions, the extraction recoveries ranging from 35.5 to 71.2 %, the relative standard deviations (RSD%) less than 6.45 %, and the detection limits in the range of 0.2-0.5 μg L-1 were achieved. The comparison of the extraction efficiency of the on-chip EME method using the electrospun PCL/MOF-199 nanofibers and PCL nanofibers membranes indicated that the proposed membrane was more efficient for extraction of sulfonamides because of the significant Lewis acid-base interactions of sulfonamides with copper uncoordinated open sites in MOF-199. Finally, the performance of the proposed method for extraction and determination of sulfonamides in three real samples was assayed.
Collapse
Affiliation(s)
- Elham Tahmasebi
- Department of Chemistry, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan 45137-66731, Iran.
| | - Arezou Javadi
- Department of Chemistry, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan 45137-66731, Iran
| |
Collapse
|
3
|
Dowlatshah S, Hansen FA, Zhou C, Ramos-Payán M, Halvorsen TG, Pedersen-Bjergaard S. Electromembrane extraction of peptides based on hydrogen bond interactions. Anal Chim Acta 2023; 1275:341610. [PMID: 37524472 DOI: 10.1016/j.aca.2023.341610] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 06/17/2023] [Accepted: 07/09/2023] [Indexed: 08/02/2023]
Abstract
BACKGROUND Electromembrane extraction (EME) of peptides reported in the scientific literature involve transfer of net positively charged peptides from an aqueous sample, through a liquid membrane, and into an aqueous acceptor solution, under the influence of an electrical field. The liquid membrane comprises an organic solvent, containing an ionic carrier. The purpose of the ionic carrier is to facilitate peptide solvation in the organic solvent based on ionic interactions. Unfortunately, ionic carriers increase the conductivity of the liquid membrane; the current in the system increases, the electrolysis in sample and acceptor is accelerated, and the extraction system tend to be unstable and suffers from drifting pH. RESULTS In the present work, a broad selection of organic solvents were tested as pure liquid membrane for EME of peptides, without ionic carrier. Several phosphates provided high mass transfer, and tri(pentyl) phosphate was selected since this solvent also provided high operational stability. Among 16 different peptides used as model analytes, tri(pentyl) phosphate extracted those with net charge +1 and with no more than two polar side chains. Tri(pentyl) phosphate served as a very strong hydrogen bond acceptor, while the protonated peptides were hydrogen bond donors. By such, hydrogen bonding served as the primary interactions responsible for mass transfer. Tri(pentyl) phosphate as liquid membrane, could exhaustively extract leu-enkephalin, met-enkephalin, and endomorphin from human blood plasma and detected by LC-MS/MS. Calibration curves were linear (r2 > 0.99) within a concentration range from 1 to 500 ng/mL, and a relative standard deviation within 12% was observed for precision studies. SIGNIFICANCE The current experiments are important because they indicate that small peptides of low polarity may be extracted selectively in EME based on hydrogen bond interactions, in systems not suffering from electrolysis.
Collapse
Affiliation(s)
- Samira Dowlatshah
- Department of Pharmacy, University of Oslo, P.O Box 1068 Blindern, 0316, Oslo, Norway
| | - Frederik André Hansen
- Department of Pharmacy, University of Oslo, P.O Box 1068 Blindern, 0316, Oslo, Norway
| | - Chen Zhou
- Department of Pharmacy, University of Oslo, P.O Box 1068 Blindern, 0316, Oslo, Norway; West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, 610041, China
| | - María Ramos-Payán
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, c/Prof. García González s/n, 41012, Seville, Spain
| | | | - Stig Pedersen-Bjergaard
- Department of Pharmacy, University of Oslo, P.O Box 1068 Blindern, 0316, Oslo, Norway; Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100, Copenhagen, Denmark.
| |
Collapse
|
4
|
Samadifar M, Yamini Y, Khataei MM, Shirani M. Automated and semi-automated packed sorbent solid phase (micro) extraction methods for extraction of organic and inorganic pollutants. J Chromatogr A 2023; 1706:464227. [PMID: 37506462 DOI: 10.1016/j.chroma.2023.464227] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Revised: 07/06/2023] [Accepted: 07/19/2023] [Indexed: 07/30/2023]
Abstract
In this study, the packed sorbent solid phase (micro) extraction methods from manual to automated modes are reviewed. The automatic methods have several remarkable advantages such as high sample throughput, reproducibility, sensitivity, and extraction efficiency. These methods include solid-phase extraction, pipette tip micro-solid phase extraction, microextraction by packed sorbent, in-tip solid phase microextraction, in-tube solid phase microextraction, lab-on-a-chip, and lab-on-a-valve. The recent application of these methods for the extraction of organic and inorganic compounds are discussed. Also, the combination of novel technologies (3D printing and robotic platforms) with the (semi)automated methods are investigated as the future trend.
Collapse
Affiliation(s)
- Mahsa Samadifar
- Department of Chemistry, Faculty of Sciences, Tarbiat Modares University, Tehran, Iran
| | - Yadollah Yamini
- Department of Chemistry, Faculty of Sciences, Tarbiat Modares University, Tehran, Iran.
| | | | - Mahboue Shirani
- Department of Chemistry, Faculty of Sciences, University of Jiroft, Jiroft, Iran
| |
Collapse
|
5
|
Sousa DVM, Pereira FV, Boratto VHM, Orlando RM. Multiphase electroextraction as a simple and fast sample preparation alternative for the digital image determination of doxorubicin in saliva. Talanta 2023; 255:124242. [PMID: 36638654 DOI: 10.1016/j.talanta.2022.124242] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Revised: 12/27/2022] [Accepted: 12/29/2022] [Indexed: 01/01/2023]
Abstract
Monitoring chemotherapeutic drugs in biological fluids is, in many cases, extremely important for dose adjustment, the maintenance of therapies, and the control of side effects. In this work, a method for determining the doxorubicin in saliva by digital image analysis (DIA) was optimised and validated. Images from a paper point were obtained using a conventional and cheap flatbed scanner at a 600 ppp resolution. The RGB data channels were obtained from the images in a region of 15 × 15 pixels around the sorbent vertex. The paper point was used as sorbent material in sample preparation using a multiphase electroextraction system. Following optimisation using a Doehlert experimental design, the method was able to simultaneously extract 66 samples in 20 min. The high selectivity of the electric field associated with the sorption capacity of the cellulosic material allowed the chemotherapy drug to be pre-concentrated and quantified in a range between 50 and 500 μg L-1 (R2 > 0.98). The method also exhibited adequate parameters (limits of detection and quantification, recovery, and precision) indicating its potential application in the monitoring of doxorubicin and similar drugs in saliva.
Collapse
|
6
|
Wang A, Feng X, He G, Xiao Y, Zhong T, Yu X. Recent advances in digital microfluidic chips for food safety analysis: Preparation, mechanism and application. Trends Food Sci Technol 2023. [DOI: 10.1016/j.tifs.2023.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/13/2023]
|
7
|
Sahragard A, Dvořák M, J. Carrasco-Correa E, Varanasupakul P, Kubáň P, Miró M. Programmable Millifluidic Platform Integrating Automatic Electromembrane Extraction Cleanup and In-Line Electrochemical Detection: A Proof of Concept. ACS Sens 2022; 7:3161-3168. [PMID: 36200176 PMCID: PMC9623577 DOI: 10.1021/acssensors.2c01648] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
A fully automatic millifluidic sensing platform coupling in-line nonsupported microelectromembrane extraction (μ-EME) with electrochemical detection (ECD) is herein proposed for the first time. Exploiting the features of the second generation of flow analysis, termed sequential injection (SI), the smart integration of SI and μ-EME-ECD enables (i) the repeatable formation of microvolumes of phases for the extraction step in a membrane-less (nonsupported) arrangement, (ii) diverting the acceptor plug to the ECD sensing device, (iii) in-line pH adjustment before the detection step, and (iv) washing of the platform for efficient removal of remnants of wetting film solvent, all entirely unsupervised. The real-life applicability of the miniaturized sensing system is studied for in-line sample cleanup and ECD of diclofenac as a model analyte after μ-EME of urine as a complex biological sample. A comprehensive study of the merits and the limitations of μ-EME solvents on ECD is presented. Under the optimal experimental conditions using 14 μL of unprocessed urine as the donor, 14 μL of 1-nonanol as the organic phase, and 14 μL of 25 mM NaOH as the acceptor in a 2.4 mm ID PTFE tubing, an extraction voltage of 250 V, and an extraction time of 10 min, an absolute (mass) extraction recovery of 48% of diclofenac in urine is obtained. The proposed flow-through system is proven to efficiently remove the interfering effect of predominantly occurring organic species in human urine on ECD with RSD% less than 8.6%.
Collapse
Affiliation(s)
- Ali Sahragard
- Department
of Chemistry, Faculty of Science, Chulalongkorn
University, Bangkok10330, Thailand
| | - Miloš Dvořák
- Institute
of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, BrnoCZ-60200, Czech Republic
| | - Enrique J. Carrasco-Correa
- CLECEM
group, Department of Analytical Chemistry, University of Valencia, C/Doctor Moliner 50, Burjassot, Valencia46100, Spain
| | - Pakorn Varanasupakul
- Department
of Chemistry, Faculty of Science, Chulalongkorn
University, Bangkok10330, Thailand
| | - Pavel Kubáň
- Institute
of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, BrnoCZ-60200, Czech Republic
| | - Manuel Miró
- FI-TRACE
Group, Department of Chemistry, Faculty of Science, University of the Balearic Islands, Carretera de Valldemossa km 7.5, Palma de Mallorca, Illes BalearsE-07122, Spain,
| |
Collapse
|
8
|
Behpour M, Maghsoudi M, Nojavan S. Analysis of methamphetamine, methadone, tramadol, and buprenorphine in biological samples by ion mobility spectrometry after electromembrane extraction in tandem with slug flow microextraction. J Chromatogr A 2022; 1678:463355. [PMID: 35908513 DOI: 10.1016/j.chroma.2022.463355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 07/16/2022] [Accepted: 07/18/2022] [Indexed: 10/17/2022]
Abstract
A novel tandem extraction method based on electromembrane extraction (EME) and slug flow microextraction (SFME) was developed for the extraction of some narcotics (methamphetamine, methadone, tramadol, and buprenorphine) from biological samples. The analytes were quantified by corona discharge-ion mobility spectrometry (CD-IMS). In this method, initially, analytes were extracted using an EME procedure (step-1). After that, the acceptor solution of the first step containing target analytes was applied in an SFME procedure (step-2) as a donor solution for further preconcentration. In the second step, analytes were extracted from an aqueous solution into an organic extractant. The optimum EME and SFME conditions were as follows: type of supported liquid membrane: 2-nitrophenyl octyl ether containing 10% v/v di-(2-ethylhexyl) phosphate, acceptor solution pH: 1.0, sample solution pH: 4.0, voltage: 248 V, extraction time: 17.5 min, tilting number of glass capillary tube: 10 times, type of the organic extractant: toluene, the concentration of NaOH solution: 400 mM. Under optimum extraction conditions, good linearity was obtained in the range of 0.50-750.0 ng/mL with coefficients of determination (r2) ≥ 0.991. The limits of detection and quantification were achieved in the range of 0.15-3.5 ng/mL and 0.50-12.0 ng/mL, respectively. The inter-day and intra-day precisions (n = 3) provided RSDs lower than 12.8% and 12.7%, respectively. Enrichment factors and extraction recoveries of the analytes were in the range of 255.7 to 505.4 and 37.6-78.3%, respectively. Comparing the EME/HPLC-UV with EME-SFME/CD-IMS showed that using the tandem extraction method improved the enrichment factors by more than 2.7 times and limits of detection and quantification by more than 15 times. Finally, this procedure was used to quantify target analytes in plasma and urine samples.
Collapse
Affiliation(s)
- Majid Behpour
- Department of analytical chemistry and pollutants, Shahid Beheshti University, G. C., Evin, Tehran 1983969411, Iran
| | - Majid Maghsoudi
- Department of analytical chemistry and pollutants, Shahid Beheshti University, G. C., Evin, Tehran 1983969411, Iran
| | - Saeed Nojavan
- Department of analytical chemistry and pollutants, Shahid Beheshti University, G. C., Evin, Tehran 1983969411, Iran.
| |
Collapse
|
9
|
Microfluidic paper-based analytical devices and electromembrane extraction; Hyphenation of fields towards effective analytical platforms. Anal Chim Acta 2022; 1216:339987. [DOI: 10.1016/j.aca.2022.339987] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2022] [Revised: 05/17/2022] [Accepted: 05/22/2022] [Indexed: 11/19/2022]
|
10
|
Magnetic Nanomaterials and Nanostructures in Sample Preparation Prior to Liquid Chromatography. MAGNETOCHEMISTRY 2022. [DOI: 10.3390/magnetochemistry8030029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Magnetic nanomaterials and nanostructures compose an innovative subject in sample preparation. Most of them are designed according to the properties of the target analytes on each occasion. The unique characteristics of nanomaterials enhance the proficiency at extracting and enriching due to their selective adsorption ability as well as easy separation and surface modification. Their remarkable properties, such as superparamagnetism, biocompatibility and selectivity have established magnetic materials as very reliable options in sample preparation approaches. In order to comprehend the range of utilization at magnetic materials and nanostructures, this review aims to present the most notable examples in sample preparation prior to liquid chromatography (LC) to the community of analytical chemists. Primarily, the review describes the principles of the techniques in which the magnetic materials are utilized and leaned on. Additionally, there is a diligent report about the novel magnetic techniques and finally a comparison to demonstrate the total point of view.
Collapse
|
11
|
Eie LV, Pedersen-Bjergaard S, Hansen FA. Electromembrane extraction of polar substances - Status and perspectives. J Pharm Biomed Anal 2022; 207:114407. [PMID: 34634529 DOI: 10.1016/j.jpba.2021.114407] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 09/20/2021] [Accepted: 09/30/2021] [Indexed: 12/15/2022]
Abstract
In this article, the scientific literature on electromembrane extraction (EME) of polar substances (log P < 2) is reviewed. EME is an extraction technique based on electrokinetic migration of analyte ions from an aqueous sample, across an organic supported liquid membrane (SLM), and into an aqueous acceptor solution. Because extraction is based on voltage-assisted partitioning, EME is fundamentally suitable for extraction of polar and ionizable substances that are challenging in many other extraction techniques. The article provides an exhaustive overview of papers on EME of polar substances. From this, different strategies to improve the mass transfer of polar substances are reviewed and critically discussed. These strategies include different SLM chemistries, modification of supporting membranes, sorbent additives, aqueous solution chemistry, and voltage/current related strategies. Finally, the future applicability of EME for polar substances is discussed. We expect EME in the coming years to be developed towards both very selective targeted analysis, as well as untargeted analysis of polar substances in biomedical applications such as metabolomics and peptidomics.
Collapse
Affiliation(s)
- Linda Vårdal Eie
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway
| | - Stig Pedersen-Bjergaard
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway; Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark
| | - Frederik André Hansen
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway.
| |
Collapse
|
12
|
Farahmandi M, Yamini Y, Baharfar M, Karami M. Dispersive magnetic solid phase microextraction on microfluidic systems for extraction and determination of parabens. Anal Chim Acta 2021; 1188:339183. [PMID: 34794570 DOI: 10.1016/j.aca.2021.339183] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 10/13/2021] [Accepted: 10/16/2021] [Indexed: 01/06/2023]
Abstract
In this study, a customized microfluidic system was utilized for magnetic solid phase extraction of parabens. For this sake, magnetite nanoparticles were synthesized and coated with polyaniline to enable efficient extraction and magnetic separation of sorbents particles. The synthesized particles were extensively characterized in terms of morphology, composition, and magnetic properties. The utilized microfluidic platform consisted of a relatively long spiral microchannel fabricated through laser-cutting and multi-layered assembly. To obtain an efficient dispersion, simultaneous flows of sample solution and magnetic beads dispersion were introduced to the chip with the aid of two syringe pumps. In order to increase the stability of the dispersed nanoparticles in the aqueous solution, various chemical and instrumental parameters were investigated and optimized. In this context, exploitation of hydrophobic surfactants and surface charge manipulation of the particles was shown to be a highly promising approach for effective dispersion and maintenance of magnetic beads in long microfluidic channels. Under the optimized conditions, the calibration curves were linear in the range of 5.0-1000.0 μg L-1 for propyl paraben and 8.0-1000.0 μg L-1 for methyl- and ethyl paraben with coefficients of determination greater than 0.992. Relative standard deviations were assessed as intra- and inter-day values which were less than 7.2% and the preconcentration factors in water were 10-15 for 100 μg L-1 of parabens in water. Finally, the method was applied for the extraction of parabens from fruit juice, sunscreen, and urine samples which showed favorable accuracy and precision.
Collapse
Affiliation(s)
- Maryam Farahmandi
- Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran
| | - Yadollah Yamini
- Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran.
| | - Mahroo Baharfar
- Graduate School of Biomedical Engineering, Faculty of Engineering, The University of New South Wales, Sydney, NSW, 2052, Australia
| | - Monireh Karami
- Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran
| |
Collapse
|
13
|
Sahragard A, Alahmad W, Varanusupakul P. Electrocolorimetric gel-based sensing approach for simultaneous extraction, preconcentration, and detection of iodide and chromium (VI) ions. Talanta 2021; 235:122715. [PMID: 34517583 DOI: 10.1016/j.talanta.2021.122715] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Revised: 07/10/2021] [Accepted: 07/12/2021] [Indexed: 12/30/2022]
Abstract
A total integrated electrocolorimetric sensing approach consisting of gel-based electromembrane extraction and colorimetric detection in a one-step process was developed. This system was designed using colorimetric reagents preadded to the agarose gel for the determination of the following two model analytes: iodide and hexavalent chromium [Cr(VI)]. In this system, when a voltage was applied, the analytes were extracted and transferred from the sample solution (donor phase) to the gel (acceptor phase). The analytes then simultaneously reacted with the colorimetric reagents inside the gel, yielding blue and violet colors for iodide and Cr(VI), respectively. These colors were then analyzed using a portable spectrometer and could also be distinguished with the naked eye. Parameters affecting the extraction efficiency were studied and optimized for both analytes. The gel composition for iodide detection was 4% (w/v) agarose, 5% (v/v) H2O2, and 1% (w/v) starch in 2 mM HCl. The gel composition for Cr(VI) detection was 2% (w/v) agarose and 1% (w/v) DPC in 0.5 mM HNO3. Both analytes were extracted at an applied potential of 50 V, an extraction time of 15 min and a stirring rate of 600 rpm. Under the optimized conditions, the developed systems provided linear responses within 15 min for iodide concentrations ranging from 50 to 250 μg L-1 with a detection limit of 18 μg L-1 and for Cr(VI) concentrations ranging from 30 to 125 μg L-1 with a detection limit of 5 μg L-1. Finally, these systems were successfully applied to the determination of iodide in iodide food supplement samples and Cr(VI) in drinking water samples, showing a negligible matrix effect. This integration could also be extended to other analytes and detection systems to develop sensitive, on-site, and environmentally friendly sensing approaches.
Collapse
Affiliation(s)
- Ali Sahragard
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, Thailand
| | - Waleed Alahmad
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, Thailand.
| | - Pakorn Varanusupakul
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, Thailand.
| |
Collapse
|
14
|
Alidoust M, Baharfar M, Manouchehri M, Yamini Y, Tajik M, Seidi S. Emergence of microfluidic devices in sample extraction; an overview of diverse methodologies, principals, and recent advancements. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116352] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
15
|
Hansen FA, Petersen NJ, Kutter JP, Pedersen-Bjergaard S. Electromembrane extraction in microfluidic formats. J Sep Sci 2021; 45:246-257. [PMID: 34562339 DOI: 10.1002/jssc.202100603] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 09/20/2021] [Accepted: 09/20/2021] [Indexed: 11/09/2022]
Abstract
Electromembrane extraction is a microextraction technique where charged analytes are extracted across a supported liquid membrane and selectively isolated from the sample based on an electrical field. Since the introduction in 2006, there has been continuously increasing interest in electromembrane extraction, and currently close to 50 new articles are published per year. Electromembrane extraction can be performed in different technical configurations, based on standard laboratory glass vials or 96-well plate systems, and applications are typically related to pharmaceutical, environmental, and food and beverages analysis. In addition to this, conceptual research has developed electromembrane extraction into different milli- and microfluidic formats. These are much more early-stage activities, but applications among others related to organ-on-chip systems and smartphone detection indicate unique perspectives. To stimulate more research in this direction, the current article reviews the scientific literature on electromembrane extraction in milli- and microfluidic formats. About 20 original research articles have been published on this subject so far, and these are discussed critically in the following. Based on this and the authors own experiences with the topic, we discuss perspectives, challenges, and future research.
Collapse
Affiliation(s)
| | - Nickolaj Jacob Petersen
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Jörg P Kutter
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Stig Pedersen-Bjergaard
- Department of Pharmacy, University of Oslo, Oslo, Norway.,Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
16
|
Impact of ion balance in electromembrane extraction. Anal Chim Acta 2020; 1124:129-136. [PMID: 32534665 DOI: 10.1016/j.aca.2020.05.039] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Revised: 05/12/2020] [Accepted: 05/14/2020] [Indexed: 01/07/2023]
Abstract
Electromembrane extraction (EME) involves transfer of analyte ions from aqueous sample, through a supported liquid membrane (SLM), and into an aqueous acceptor solution under the influence of an external electrical field. In addition to target analyte ions, the sample also contains matrix ions, and both the sample and acceptor contains background buffer ions to control pH. The ratio between the total amount of ions in sample and acceptor defines the ion balance (χ). Previous publications have discussed the impact of ion balance, but conclusions are contradictory. Therefore, the current paper investigated the ion balance in more detail. From a theoretical point of view, low χ-values favor EME; buffer anions at high concentration in the acceptor migrate into the SLM, while target cations enters the SLM from the sample to maintain electroneutrality. A large number of experiments was performed in this paper to investigate the practical impact of ion balance. Twelve basic drugs were used as model analytes (0.0 < log P < 5.0), and 2-nitrophenyl octyl ether (NPOE) and NPOE + 5% di(2-ethylhexyl) phosphate (DEHP) were used as SLM. With formate buffer pH 3.75 as sample and acceptor, the impact of χ in the range 0.01-10 was studied without bias from differences in pH. Here model analytes were unaffected by ion balance. Buffers containing propionic, butyric, and valeric acid were also tested. These buffer ions migrated more into the SLM, and affected recoveries in several cases. However, this was due to ion pairing rather than effects of ion balance. Similar behaviors from sodium chloride and urine samples were observed with different χ-values. Thus, in the systems tested, almost no impact of ion balance was found, and this was attributed to very low partition of background buffer and matrix ions into the SLM. On the other hand, extractions were in several cases influenced by ion pairing phenomena.
Collapse
|
17
|
Khan WA, Arain MB, Yamini Y, Shah N, Kazi TG, Pedersen-Bjergaard S, Tajik M. Hollow fiber-based liquid phase microextraction followed by analytical instrumental techniques for quantitative analysis of heavy metal ions and pharmaceuticals. J Pharm Anal 2020; 10:109-122. [PMID: 32373384 PMCID: PMC7192972 DOI: 10.1016/j.jpha.2019.12.003] [Citation(s) in RCA: 56] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Revised: 12/09/2019] [Accepted: 12/11/2019] [Indexed: 02/07/2023] Open
Abstract
Hollow-fiber liquid-phase microextraction (HF-LPME) and electromembrane extraction (EME) are miniaturized extraction techniques, and have been coupled with various analytical instruments for trace analysis of heavy metals, drugs and other organic compounds, in recent years. HF-LPME and EME provide high selectivity, efficient sample cleanup and enrichment, and reduce the consumption of organic solvents to a few micro-liters per sample. HF-LPME and EME are compatible with different analytical instruments for chromatography, electrophoresis, atomic spectroscopy, mass spectrometry, and electrochemical detection. HF-LPME and EME have gained significant popularity during the recent years. This review focuses on hollow fiber based techniques (especially HF-LPME and EME) of heavy metals and pharmaceuticals (published 2017 to May 2019), and their combinations with atomic spectroscopy, UV-VIS spectrophotometry, high performance liquid chromatography, gas chromatography, capillary electrophoresis, and voltammetry.
Collapse
Affiliation(s)
- Wajid Ali Khan
- Department of Chemistry, Abdul Wali Khan University Mardan, 23200, KPK, Pakistan
| | - Muhammad Balal Arain
- Department of Chemistry, Abdul Wali Khan University Mardan, 23200, KPK, Pakistan
- Department of Chemistry, University of Karachi, 75270, Karachi, Pakistan
| | - Yadollah Yamini
- Department of Chemistry, Tarbiat Modares University, P. O. Box 14115-175, Tehran, Iran
| | - Nasrullah Shah
- Department of Chemistry, Abdul Wali Khan University Mardan, 23200, KPK, Pakistan
| | - Tasneem Gul Kazi
- National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Sindh, Pakistan
| | | | - Mohammad Tajik
- Department of Chemistry, Tarbiat Modares University, P. O. Box 14115-175, Tehran, Iran
| |
Collapse
|
18
|
Wang TT, Lio CK, Huang H, Wang RY, Zhou H, Luo P, Qing LS. A feasible image-based colorimetric assay using a smartphone RGB camera for point-of-care monitoring of diabetes. Talanta 2020; 206:120211. [DOI: 10.1016/j.talanta.2019.120211] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Revised: 07/23/2019] [Accepted: 07/31/2019] [Indexed: 01/11/2023]
|