1
|
Lei KF, Lin YT, Boreddy SKR, Pai PC. Analysis of chemosensitivity of tumor spheroids exposed to two-dimensional gradient of combination drugs in a hydrogel-based diffusion microfluidic platform. Anal Chim Acta 2024; 1332:343371. [PMID: 39580177 DOI: 10.1016/j.aca.2024.343371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2024] [Accepted: 10/23/2024] [Indexed: 11/25/2024]
Abstract
BACKGROUND Liver cancer stands as a leading cause of cancer-related deaths globally, challenging conventional treatments due to resistance to chemotherapy and targeted therapy. Although frontline medications show initial efficacy, prolonged use often leads to resistance and harm. Current clinical strategies rely on combination therapies, but evaluating their effectiveness remains challenging. RESULTS To address this, we developed a hydrogel-based diffusion microfluidic platform for assessing chemosensitivity. This platform features a hydrogel-filled diffusion layer linked to liquid wells, allowing the creation of drug gradients. Tumor spheroids, cultured on the non-adhesive hydrogel surface, were exposed to single or combination drug gradients. Analysis revealed that drug efficacy, quantified by IC50 values, could be determined from responses to single drug gradients. A novel method was introduced to assess spheroid circularity as a time-invariant index of drug efficacy. Furthermore, exposing spheroids to 2D combination drug gradients allowed intuitive visualization of their responses via a color map. This analysis identified optimal drug combinations, exhibiting superior efficacy to monotherapy. SIGNIFICANCE The microfluidic platform enables assessment of synergistic effects and replicates in vivo conditions, enhancing the relevance of test results. By offering a streamlined, fast, and efficient drug screening approach, this platform aims to provide insight into tumor spheroid responses to varying drug combinations, facilitating more effective clinical applications.
Collapse
Affiliation(s)
- Kin Fong Lei
- Department of Biomedical Engineering, Chang Gung University, Taoyuan, Taiwan; Department of Radiation Oncology, Chang Gung Memorial Hospital, Linkou, Taiwan; Department of Electrical & Electronic Engineering, Yonsei University, Seoul, South Korea.
| | - Yu-Ting Lin
- Department of Biomedical Engineering, Chang Gung University, Taoyuan, Taiwan
| | | | - Ping-Ching Pai
- Department of Radiation Oncology, Chang Gung Memorial Hospital, Linkou, Taiwan
| |
Collapse
|
2
|
Kaladharan K, Ouyang CH, Yang HY, Tseng FG. Selectively cross-linked hydrogel-based cocktail drug delivery micro-chip for colon cancer combinatorial drug screening using AI-CSR platform for precision medicine. LAB ON A CHIP 2024; 24:4766-4777. [PMID: 39246026 DOI: 10.1039/d4lc00520a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/10/2024]
Abstract
Cancer, ranked as the second leading cause of global mortality with a prevalence of 1 in 6 deaths, necessitates innovative approaches for effective treatment. Combinatorial drug therapy for cancer treatment targets several key pathways simultaneously and potentially enhances anti-cancer efficacy without intolerable side effects. However, it demands precise and accurate control of drug-dose combinations and their release. In this study, we demonstrated a selectively cross-linked hydrogel-based platform that can quantify and release drugs simultaneously for in-parallel cocktail drug screening. PDMS was used as the flow channel substrate and the poly (ethylene glycol) diacrylate (PEGDA) hydrogel array was formed by UV exposure using the photomask. Employing our platform, cocktails of anticancer drugs are precisely loaded and simultaneously released in-parallel into HCT-116 colon cancer cells, facilitating combinatorial drug screening. The integration of an artificial intelligence-based complex system response (AI-CSR) platform successfully identifies optimal drug-dose combinations from a pool of ten approved drugs. Notably, our cocktail drug chip demonstrates exceptional efficiency, screening 155 drug-dose combinations within a brief two and a half hours, a marked improvement over traditional methods. Furthermore, the device exhibits low drug consumption, requiring a mere 1 μL per patch of chip. Thus, our developed PDMS drug-loaded hydrogel platform presents a novel and expedited approach to quantifying drug concentrations, promising to be a faster, efficient and more precise approach for conducting cocktail drug screening experiments.
Collapse
Affiliation(s)
- Kiran Kaladharan
- Engineering and System Science, National Tsing Hua University, Hsinchu, Taiwan, Republic of China.
| | - Chih-Hsuan Ouyang
- Engineering and System Science, National Tsing Hua University, Hsinchu, Taiwan, Republic of China.
| | - Hsin-Yu Yang
- Engineering and System Science, National Tsing Hua University, Hsinchu, Taiwan, Republic of China.
| | - Fan-Gang Tseng
- Engineering and System Science, National Tsing Hua University, Hsinchu, Taiwan, Republic of China.
- Institute of Nano Engineering and Microsystems, National Tsing Hua University, Hsinchu, Taiwan
- Department of Chemistry, National Tsing Hua University, Hsinchu, Taiwan
- Research Center for Applied Sciences, Academia Sinica, Taipei, Taiwan, Republic of China
| |
Collapse
|
3
|
Zhao M, Yang J, Li Z, Zeng Y, Tao C, Dai B, Zhang D, Yamaguchi Y. High-throughput 3D microfluidic chip for generation of concentration gradients and mixture combinations. LAB ON A CHIP 2024; 24:2280-2286. [PMID: 38506153 DOI: 10.1039/d3lc00822c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/21/2024]
Abstract
Concentration gradient generation and mixed combinations of multiple solutions are of great value in the field of biomedical research. However, existing concentration gradient generators for single or two-drug solutions cannot simultaneously achieve multiple concentration gradient formations and mixed solution combinations. Furthermore, the whole system was huge, and required expensive auxiliary equipment, which may lead to complex operations. To address this problem, we devised a novel 3D microchannel network design, which is capable of creating all the desired mixture combinations and concentration gradients of given small amounts of the input solutions. As a proof of concept, the device we presented was verified by both colorimetric and fluorescence detection methods to test the efficiency. This can enable the implementation of one to three solutions with no driving pump and facilitate unique multiple types of more concentration gradients and mixture combinations in a single operation. We envision that this will be a promising candidate for the development of simplified methods for screening of the appropriate concentration and combination, such as various drug screening applications.
Collapse
Affiliation(s)
- Mingwei Zhao
- Engineering Research Center of Optical Instrument and System, Key Lab of Optical Instruments and Equipment for Medical Engineering, Ministry of Education, Shanghai Key Lab of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China.
| | - Jing Yang
- Anhui Sanlian University, Hefei 230000, China
| | - Zhenqing Li
- Engineering Research Center of Optical Instrument and System, Key Lab of Optical Instruments and Equipment for Medical Engineering, Ministry of Education, Shanghai Key Lab of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China.
| | - Yuan Zeng
- College of Medical Imaging, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
| | - Chunxian Tao
- Engineering Research Center of Optical Instrument and System, Key Lab of Optical Instruments and Equipment for Medical Engineering, Ministry of Education, Shanghai Key Lab of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China.
| | - Bo Dai
- Engineering Research Center of Optical Instrument and System, Key Lab of Optical Instruments and Equipment for Medical Engineering, Ministry of Education, Shanghai Key Lab of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China.
| | - Dawei Zhang
- Engineering Research Center of Optical Instrument and System, Key Lab of Optical Instruments and Equipment for Medical Engineering, Ministry of Education, Shanghai Key Lab of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China.
| | - Yoshinori Yamaguchi
- Picotecbio-Waseda Joint Research Lab, Comprehensive Research Organization, Waseda University, 94-A203, 1011, NishiTomita, Honjo, Saitama, 367-0035, Japan
| |
Collapse
|
4
|
Bae J, Jeon H, Kim T. Full-Combinatorial Concentration Gradient Array with 3D Micro/Nanofluidics for Antibiotic Susceptibility Testing. Anal Chem 2024; 96:5462-5470. [PMID: 38511829 DOI: 10.1021/acs.analchem.3c05501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/22/2024]
Abstract
Recent advancements in micro/nanofluidics have facilitated on-chip microscopy of cellular responses in a high-throughput and controlled microenvironment with the desired physicochemical properties. Despite its potential benefits to combination drug discovery, generating a complete combinatorial set of concentration gradients for multiple reagents in an array format remains challenging. The main reason is limited layouts of conventional micro/nanofluidic systems based on two-dimensional channel networks. In this paper, we present a device with three-dimensional (3D) interconnection of micro/nanochannels capable of generating a complete combinatorial set of concentration gradients for two reagents. The device was readily fabricated by laminating a pair of multilayered monolithic films containing a Christmas tree-like mixer, a cell culture chamber array, and through-holes, all within each single film. We assessed the reliable generation of a full-combinatorial concentration gradient array and validated it by using numerical analysis. We applied the proposed device to test the antibiotic susceptibility of bacterial cells in a convenient one-step manner. Furthermore, we explored the potential of the device to accommodate the arrayed complete combinatorial set for two or more drugs, while extending the capabilities of our laminated object manufacturing method for realizing 3D micro/nanofluidic systems.
Collapse
Affiliation(s)
- Juyeol Bae
- Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-Gil, Ulsan 44919, Republic of Korea
| | - Hwisu Jeon
- Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-Gil, Ulsan 44919, Republic of Korea
- TK Medical Solution Inc., 50 UNIST-Gil, Ulsan 44919, Republic of Korea
| | - Taesung Kim
- Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-Gil, Ulsan 44919, Republic of Korea
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-Gil, Ulsan 44919, Republic of Korea
- TK Medical Solution Inc., 50 UNIST-Gil, Ulsan 44919, Republic of Korea
| |
Collapse
|
5
|
Li C, Holman JB, Shi Z, Qiu B, Ding W. On-chip modeling of tumor evolution: Advances, challenges and opportunities. Mater Today Bio 2023; 21:100724. [PMID: 37483380 PMCID: PMC10359640 DOI: 10.1016/j.mtbio.2023.100724] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 06/16/2023] [Accepted: 07/06/2023] [Indexed: 07/25/2023] Open
Abstract
Tumor evolution is the accumulation of various tumor cell behaviors from tumorigenesis to tumor metastasis and is regulated by the tumor microenvironment (TME). However, the mechanism of solid tumor progression has not been completely elucidated, and thus, the development of tumor therapy is still limited. Recently, Tumor chips constructed by culturing tumor cells and stromal cells on microfluidic chips have demonstrated great potential in modeling solid tumors and visualizing tumor cell behaviors to exploit tumor progression. Herein, we review the methods of developing engineered solid tumors on microfluidic chips in terms of tumor types, cell resources and patterns, the extracellular matrix and the components of the TME, and summarize the recent advances of microfluidic chips in demonstrating tumor cell behaviors, including proliferation, epithelial-to-mesenchymal transition, migration, intravasation, extravasation and immune escape of tumor cells. We also outline the combination of tumor organoids and microfluidic chips to elaborate tumor organoid-on-a-chip platforms, as well as the practical limitations that must be overcome.
Collapse
Affiliation(s)
- Chengpan Li
- Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, Anhui, 230027, China
- Center for Biomedical Imaging, University of Science and Technology of China, Hefei, Anhui, 230027, China
| | - Joseph Benjamin Holman
- Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, Anhui, 230027, China
| | - Zhengdi Shi
- Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, Anhui, 230027, China
| | - Bensheng Qiu
- Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, Anhui, 230027, China
- Center for Biomedical Imaging, University of Science and Technology of China, Hefei, Anhui, 230027, China
| | - Weiping Ding
- Department of Oncology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, China
| |
Collapse
|
6
|
Cardoso BD, Castanheira EMS, Lanceros‐Méndez S, Cardoso VF. Recent Advances on Cell Culture Platforms for In Vitro Drug Screening and Cell Therapies: From Conventional to Microfluidic Strategies. Adv Healthc Mater 2023; 12:e2202936. [PMID: 36898671 PMCID: PMC11468737 DOI: 10.1002/adhm.202202936] [Citation(s) in RCA: 33] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 02/27/2023] [Indexed: 03/12/2023]
Abstract
The clinical translations of drugs and nanomedicines depend on coherent pharmaceutical research based on biologically accurate screening approaches. Since establishing the 2D in vitro cell culture method, the scientific community has improved cell-based drug screening assays and models. Those advances result in more informative biochemical assays and the development of 3D multicellular models to describe the biological complexity better and enhance the simulation of the in vivo microenvironment. Despite the overall dominance of conventional 2D and 3D cell macroscopic culture methods, they present physicochemical and operational challenges that impair the scale-up of drug screening by not allowing a high parallelization, multidrug combination, and high-throughput screening. Their combination and complementarity with microfluidic platforms enable the development of microfluidics-based cell culture platforms with unequivocal advantages in drug screening and cell therapies. Thus, this review presents an updated and consolidated view of cell culture miniaturization's physical, chemical, and operational considerations in the pharmaceutical research scenario. It clarifies advances in the field using gradient-based microfluidics, droplet-based microfluidics, printed-based microfluidics, digital-based microfluidics, SlipChip, and paper-based microfluidics. Finally, it presents a comparative analysis of the performance of cell-based methods in life research and development to achieve increased precision in the drug screening process.
Collapse
Affiliation(s)
- Beatriz D. Cardoso
- Physics Centre of Minho and Porto Universities (CF‐UM‐UP), Campus de GualtarUniversity of MinhoBraga4710‐057Portugal
- LaPMET‐Laboratory of Physics for Materials and Emergent TechnologiesUniversity of Minho4710‐057BragaPortugal
- Center for MicroElectromechanical Systems (CMEMS‐UMinho)Campus de AzurémUniversity of Minho4800‐058GuimarãesPortugal
- LABBELS‐Associate Laboratory in Biotechnology and Bioengineering and Microelectromechanical SystemsUniversity of MinhoBraga/GuimarãesPortugal
| | - Elisabete M. S. Castanheira
- Physics Centre of Minho and Porto Universities (CF‐UM‐UP), Campus de GualtarUniversity of MinhoBraga4710‐057Portugal
- LaPMET‐Laboratory of Physics for Materials and Emergent TechnologiesUniversity of Minho4710‐057BragaPortugal
| | - Senentxu Lanceros‐Méndez
- Physics Centre of Minho and Porto Universities (CF‐UM‐UP), Campus de GualtarUniversity of MinhoBraga4710‐057Portugal
- LaPMET‐Laboratory of Physics for Materials and Emergent TechnologiesUniversity of Minho4710‐057BragaPortugal
- BCMaterialsBasque Center for MaterialsApplications and NanostructuresUPV/EHU Science ParkLeioa48940Spain
- IKERBASQUEBasque Foundation for ScienceBilbao48009Spain
| | - Vanessa F. Cardoso
- Center for MicroElectromechanical Systems (CMEMS‐UMinho)Campus de AzurémUniversity of Minho4800‐058GuimarãesPortugal
- LABBELS‐Associate Laboratory in Biotechnology and Bioengineering and Microelectromechanical SystemsUniversity of MinhoBraga/GuimarãesPortugal
| |
Collapse
|
7
|
Shen S, Zhang F, Zhang Y, Li Y, Niu Y, Pang L, Wang J. Construction of multiple concentration gradients for single-cell level drug screening. MICROSYSTEMS & NANOENGINEERING 2023; 9:46. [PMID: 37064165 PMCID: PMC10102073 DOI: 10.1038/s41378-023-00516-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Revised: 02/27/2023] [Accepted: 02/27/2023] [Indexed: 06/19/2023]
Abstract
Isolation and manipulation of single cells play a crucial role in drug screening. However, previously reported single-cell drug screening lacked multiple-dose concentration gradient studies, which limits their ability to predict drug performance accurately. To solve this problem, we constructed a multiconcentration gradient generator in which a Tai Chi-spiral mixer can accelerate solution mixing in a short time and produce a linear concentration gradient. Later, a gradient generator combined with a single-cell capture array was adopted to investigate the effects of single or combined doses of 5-fluorouracil and cisplatin on human hepatoma cells and human breast carcinoma cells (at the single-cell level). The results showed that both drugs were effective in inhibiting the growth of cancer cells, and the combination was more effective for human hepatoma cells. In addition, the relationship between the biomechanical heterogeneity (e.g., deformability and size) of tumor cells and potential drug resistance at the single-cell level was investigated, indicating that small and/or deformable cells were more resistant than large and/or less deformable cells. The device provides a simple and reliable platform for studying the optimal dosage of different drug candidates at the single-cell level and effectively screening single-agent chemotherapy regimens and combination therapies.
Collapse
Affiliation(s)
- Shaofei Shen
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taigu, Shanxi 030801 China
| | - Fangjuan Zhang
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taigu, Shanxi 030801 China
| | - Yali Zhang
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taigu, Shanxi 030801 China
| | - Yi Li
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taigu, Shanxi 030801 China
| | - Yanbing Niu
- Shanxi Key Lab for Modernization of TCVM, College of Life Science, Shanxi Agricultural University, Taigu, Shanxi 030801 China
| | - Long Pang
- School of Basic Medical Science, Xi’an Medical University, Xi’an, Shaanxi 710021 China
| | - Jinyi Wang
- College of Chemistry and Pharmacy, Northwest A&F University, Yangling, Shaanxi 712100 China
| |
Collapse
|
8
|
Zhang X, Zhao YN, Wei X, Men X, Wu CX, Bai JJ, Yang T, Chen ML, Wang JH. Intolerance of profligacy: an aptamer concentration gradient-tailored unicellular array for high-throughput biologics-mediated phenotyping. LAB ON A CHIP 2022; 22:4238-4245. [PMID: 36194170 DOI: 10.1039/d2lc00729k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
In aptamer-based assay schemes, aptamer probes not labeled with biomarkers have to be eliminated before testing, which may lead to a tremendous waste of precious probes. We herein propose a microfluidics system integrating an aptamer concentration gradient generator (Apt-CGG) and a dual single-cell culturing array (D-SCA), termed Mi-Apt-SCA. This facilitates the precise construction of a nanoscale-gradient microenvironment and the high-throughput profiling of single-cell growth/phenotypes in situ with the minimal consumption of Apt-probe. Unlike previous snakelike mixers, the choreographed winding-ravined aptamer dual-spiral micromixer (Apt-WD-mixer) in Apt-CGG could allow thorough blending to generate linear concentration gradients of aptamer (quasi-non-Newtonian fluid) under the action of continuous fluidic wiggles and bidirectional Dean flow. In contrast to other trap-like systems, the mild vortex allows single-cell growth in an ultra-tender fluidic microenvironment using triple-jarless single-cell culture capsules (TriJ-SCCs) in D-SCA (shear stress: 3.43 × 10-5 dynes per cm2). The minimum dosage of aptamer probe required for exploring PDL1 protein expression in two hepatoma cell lines is only one-900th of that required by conventional protocols. In addition, this approach facilitated the profiling of ITF-β/cisplatin-mediated single-cell/cell-cluster phenotypes.
Collapse
Affiliation(s)
- Xuan Zhang
- Department of Chemistry, College of Sciences, Northeastern University, Shenyang, 110819, China.
| | - Ya-Nan Zhao
- Department of Chemistry, College of Sciences, Northeastern University, Shenyang, 110819, China.
| | - Xing Wei
- Department of Chemistry, College of Sciences, Northeastern University, Shenyang, 110819, China.
| | - Xue Men
- Department of Chemistry, College of Sciences, Northeastern University, Shenyang, 110819, China.
| | - Cheng-Xin Wu
- Department of Chemistry, College of Sciences, Northeastern University, Shenyang, 110819, China.
| | - Jun-Jie Bai
- Department of Chemistry, College of Sciences, Northeastern University, Shenyang, 110819, China.
| | - Ting Yang
- Department of Chemistry, College of Sciences, Northeastern University, Shenyang, 110819, China.
| | - Ming-Li Chen
- Department of Chemistry, College of Sciences, Northeastern University, Shenyang, 110819, China.
| | - Jian-Hua Wang
- Department of Chemistry, College of Sciences, Northeastern University, Shenyang, 110819, China.
| |
Collapse
|
9
|
De Stefano P, Bianchi E, Dubini G. The impact of microfluidics in high-throughput drug-screening applications. BIOMICROFLUIDICS 2022; 16:031501. [PMID: 35646223 PMCID: PMC9142169 DOI: 10.1063/5.0087294] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 05/02/2022] [Indexed: 05/05/2023]
Abstract
Drug discovery is an expensive and lengthy process. Among the different phases, drug discovery and preclinical trials play an important role as only 5-10 of all drugs that begin preclinical tests proceed to clinical trials. Indeed, current high-throughput screening technologies are very expensive, as they are unable to dispense small liquid volumes in an accurate and quick way. Moreover, despite being simple and fast, drug screening assays are usually performed under static conditions, thus failing to recapitulate tissue-specific architecture and biomechanical cues present in vivo even in the case of 3D models. On the contrary, microfluidics might offer a more rapid and cost-effective alternative. Although considered incompatible with high-throughput systems for years, technological advancements have demonstrated how this gap is rapidly reducing. In this Review, we want to further outline the role of microfluidics in high-throughput drug screening applications by looking at the multiple strategies for cell seeding, compartmentalization, continuous flow, stimuli administration (e.g., drug gradients or shear stresses), and single-cell analyses.
Collapse
Affiliation(s)
- Paola De Stefano
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “G. Natta,” Politecnico di Milano, Italy
| | - Elena Bianchi
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “G. Natta,” Politecnico di Milano, Italy
| | - Gabriele Dubini
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering “G. Natta,” Politecnico di Milano, Italy
| |
Collapse
|
10
|
Micro/nanofluidic devices for drug delivery. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 187:9-39. [PMID: 35094782 DOI: 10.1016/bs.pmbts.2021.07.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Micro/nanofluidic drug delivery systems have attracted significant attention as they offer unique advantages in targeted and controlled drug delivery. Based on the desired application, these systems can be categorized into three different groups: in vitro, in situ and in vivo microfluidic drug delivery platforms. In vitro microfluidic drug delivery platforms are closely linked with the emerging concept of lab-on-a-chip for cell culture studies. These systems can be used to administer drugs or therapeutic agents, mostly at the cellular or tissue level, to find the therapeutic index and can potentially be used for personalized medicine. In situ and in vivo microfluidic drug delivery platforms are still at the developmental stage and can be used for drug delivery at tissue or organ levels. A famous example of these systems are microneedles that can be used for painless and controllable delivery of drugs or vaccines through human skin. This chapter presents the cutting edge advances in the design and fabrication of in vitro microfluidic drug delivery systems that can be used for both cellular and tissue drug delivery. It also briefly discusses the in situ drug delivery platforms using microneedles.
Collapse
|
11
|
Jia X, Yang X, Luo G, Liang Q. Recent progress of microfluidic technology for pharmaceutical analysis. J Pharm Biomed Anal 2021; 209:114534. [PMID: 34929566 DOI: 10.1016/j.jpba.2021.114534] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 12/06/2021] [Accepted: 12/08/2021] [Indexed: 12/13/2022]
Abstract
In recent years, the progress of microfluidic technology has provided new tools for pharmaceutical analysis and the proposal of pharm-lab-on-a-chip is appealing for its great potential to integrate pharmaceutical test and pharmacological test in a single chip system. Here, we summarize and highlight recent advances of chip-based principles, techniques and devices for pharmaceutical test and pharmacological/toxicological test focusing on the separation and analysis of drug molecules on a chip and the construction of pharmacological models on a chip as well as their demonstrative applications in quality control, drug screening and precision medicine. The trend and challenge of microfluidic technology for pharmaceutical analysis are also discussed and prospected. We hope this review would update the insight and development of pharm-lab-on-a-chip.
Collapse
Affiliation(s)
- Xiaomeng Jia
- Center for Synthetic and Systems Biology, MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Department of Chemistry, Tsinghua University, Beijing 100084, PR China
| | - Xiaoping Yang
- Center for Synthetic and Systems Biology, MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Department of Chemistry, Tsinghua University, Beijing 100084, PR China
| | - Guoan Luo
- Center for Synthetic and Systems Biology, MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Department of Chemistry, Tsinghua University, Beijing 100084, PR China.
| | - Qionglin Liang
- Center for Synthetic and Systems Biology, MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Department of Chemistry, Tsinghua University, Beijing 100084, PR China.
| |
Collapse
|
12
|
Zhang X, Wei X, Men X, Wu CX, Bai JJ, Li WT, Yang T, Chen ML, Wang JH. Dual-Multivalent-Aptamer-Conjugated Nanoprobes for Superefficient Discerning of Single Circulating Tumor Cells in a Microfluidic Chip with Inductively Coupled Plasma Mass Spectrometry Detection. ACS APPLIED MATERIALS & INTERFACES 2021; 13:43668-43675. [PMID: 34473482 DOI: 10.1021/acsami.1c11953] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The efficient recognition of circulating tumor cells (CTCs) with an aptamer probe confers numerous benefits; however, the stability and binding affinity of aptamers are significantly hampered in real biological sample matrices. Inspired by the efficient preying mechanism by multiplex tubing feet and endoskeletons of sea urchins, we engineered a superefficient biomimetic single-CTC recognition platform by conjugating dual-multivalent-aptamers (DMAs) Sgc8 and SYL3C onto AuNPs to form a sea urchin-like nanoprobe (sea urchin-DMA-AuNPs). Aptamers Sgc8 and SYL3C selectively bind with the biomarker proteins PTK7 and EpCAM expressed on the surface of CTCs. CTCs were captured with 100% efficiency, followed by sorting on a specially designed multifunctional microfluidic configuration, integrating a single-CTC separation unit and a hydrodynamic filtrating purification unit. After sorting, background-free analysis of biomarker proteins in single CTCs was undertaken with inductively coupled plasma mass spectrometry by measuring the amount of 197Au isotope in sea urchin-DMA-AuNPs. With respect to a single-aptamer nanoprobe/-interface, the dual-aptamer nanoprobe improves the binding efficiency by more than 200% (Kd < 0.35 nM). The microchip facilitates the recognition of single CTCs with a sorting separation rate of 93.6% at a flow rate of 60 μL min-1, and it exhibits 73.8 ± 5.0% measurement efficiency for single CTCs. The present strategy ensures the manipulation and detection of a single CTC in 100 μL of whole blood within 1 h.
Collapse
Affiliation(s)
- Xuan Zhang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Xing Wei
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Xue Men
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Cheng-Xin Wu
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Jun-Jie Bai
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Wei-Tao Li
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Ting Yang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Ming-Li Chen
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Jian-Hua Wang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| |
Collapse
|
13
|
Shi Y, Cai Y, Cao Y, Hong Z, Chai Y. Recent advances in microfluidic technology and applications for anti-cancer drug screening. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2020.116118] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
14
|
Concentration Gradient Constructions Using Inertial Microfluidics for Studying Tumor Cell-Drug Interactions. MICROMACHINES 2020; 11:mi11050493. [PMID: 32408585 PMCID: PMC7281261 DOI: 10.3390/mi11050493] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/28/2020] [Revised: 05/03/2020] [Accepted: 05/11/2020] [Indexed: 11/30/2022]
Abstract
With the continuous development of cancer therapy, conventional animal models have exposed a series of shortcomings such as ethical issues, being time consuming and having an expensive cost. As an alternative method, microfluidic devices have shown advantages in drug screening, which can effectively shorten experimental time, reduce costs, improve efficiency, and achieve a large-scale, high-throughput and accurate analysis. However, most of these microfluidic technologies are established for narrow-range drug-concentration screening based on sensitive but limited flow rates. More simple, easy-to operate and wide-ranging concentration-gradient constructions for studying tumor cell–drug interactions in real-time have remained largely out of reach. Here, we proposed a simple and compact device that can quickly construct efficient and reliable drug-concentration gradients with a wide range of flow rates. The dynamic study of concentration-gradient formation based on successive spiral mixer regulations was investigated systematically and quantitatively. Accurate, stable, and controllable dual drug-concentration gradients were produced to evaluate simultaneously the efficacy of the anticancer drug against two tumor cell lines (human breast adenocarcinoma cells and human cervical carcinoma cells). Results showed that paclitaxel had dose-dependent effects on the two tumor cell lines under the same conditions, respectively. We expect this device to contribute to the development of microfluidic chips as a portable and economical product in terms of the potential of concentration gradient-related biochemical research.
Collapse
|
15
|
Zhang X, Wei X, Wei Y, Chen M, Wang J. The up-to-date strategies for the isolation and manipulation of single cells. Talanta 2020; 218:121147. [PMID: 32797903 DOI: 10.1016/j.talanta.2020.121147] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 05/07/2020] [Accepted: 05/08/2020] [Indexed: 02/06/2023]
Abstract
Due to the large cellular heterogeneity, the strategies for the isolation and manipulation of single cells have been pronounced indispensable in the fields of disease diagnostics, drug delivery, and cancer biology at the single-cell resolution. Herein, an overview of the up-to-date techniques for precise manipulation/separation and analysis of single-cell is accomplished, these include the various approaches for the isolation and detection of individual cells in flow cytometry, microfluidic systems, micromodule systems, and others. In addition, the advanced application of these protocols is discussed. In particular, a few designs are highlighted for visualization, non-invasion, and intelligentization in single cell analysis, i.e., imaging flow cytometry, label-free microfluidic platform, single-cell capillary probe, and other related techniques. At the present, the main barriers in the various schemes for single cell manipulation which limited their practical applications are their cumbersome construction and single-functionality. The future opportunities and outstanding challenges in the isolation/manipulation of single cells are depicted.
Collapse
Affiliation(s)
- Xuan Zhang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, Liaoning, 110819, China
| | - Xing Wei
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, Liaoning, 110819, China
| | - Yujia Wei
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, Liaoning, 110819, China
| | - Mingli Chen
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, Liaoning, 110819, China; Analytical and Testing Center, Northeastern University, Shenyang, Liaoning, 110819, China.
| | - Jianhua Wang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, Liaoning, 110819, China.
| |
Collapse
|
16
|
Zhang X, Wei X, Men X, Jiang Z, Ye WQ, Chen ML, Yang T, Xu ZR, Wang JH. Inertial-Force-Assisted, High-Throughput, Droplet-Free, Single-Cell Sampling Coupled with ICP-MS for Real-Time Cell Analysis. Anal Chem 2020; 92:6604-6612. [PMID: 32233376 DOI: 10.1021/acs.analchem.0c00376] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Single-cell analysis facilitates perception into the most essential processes in life's mysteries. While it is highly challenging to quantify them at the single-cell level, where precise single-cell sampling is the prerequisite. Herein, a real-time single-cell quantitative platform was established for high-throughput droplet-free single-cell sampling into time-resolved (TRA) ICP-MS and real-time quantification of intracellular target elements. The concentrated cells (2 × 106 cells mL-1) were spontaneously and orderly aligned in a spiral microchannel with 104 periodic dimensional confined micropillars. The quantification is conducted simultaneously by internal standard inducing from another branch channel in the chip. The flow-rate-independent feature of single-cell focusing into an aligned stream within a wide range of fluidic velocities (100-800 μL min-1) facilitates high-throughput, oil-free, single-cell introduction into TRA-ICP-MS. The system was used for real-time exploration of intracellular antagonism of Cu2+ against Cd2+. an obvious antagonistic effect was observed for the MCF-7 cell by culturing for 3, 6, 9, and 12 h with 100 μg L-1 Cd2+ and 100 μg L-1 Cu2+, and a rivalry rate of 12.8% was achieved at 12 h. At identical experimental conditions, however, limited antagonistic effect was encountered for a bEnd3 cell within the same incubation time period, with a rivalry rate of 4.81%. On the contrary, an antagonistic effect was not observed for the HepG2 cell by culturing for 6 h, while an obvious antagonistic effect was found by further culturing to 12 h, with a rivalry rate of 10.43%. For all three cell lines, significant heterogeneity was observed among individual cells.
Collapse
Affiliation(s)
- Xuan Zhang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, Liaoning 110819, People's Republic of China
| | - Xing Wei
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, Liaoning 110819, People's Republic of China
| | - Xue Men
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, Liaoning 110819, People's Republic of China
| | - Ze Jiang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, Liaoning 110819, People's Republic of China
| | - Wen-Qi Ye
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, Liaoning 110819, People's Republic of China
| | - Ming-Li Chen
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, Liaoning 110819, People's Republic of China
| | - Ting Yang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, Liaoning 110819, People's Republic of China
| | - Zhang-Run Xu
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, Liaoning 110819, People's Republic of China
| | - Jian-Hua Wang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, Liaoning 110819, People's Republic of China
| |
Collapse
|