1
|
Gao W, Jing W, Du Y, Li Z, Liu P, Han F, Zhao L, Yang Z, Jiang Z. Regulating the Polypyrrole Ion-Selective Membrane and Au Solid Contact Layer to Improve the Performance of Nitrate All-Solid Ion-Selective Electrodes. MICROMACHINES 2023; 14:855. [PMID: 37421088 DOI: 10.3390/mi14040855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 04/11/2023] [Accepted: 04/13/2023] [Indexed: 07/09/2023]
Abstract
With polymerization duration and Au3+ concentration of the electrolyte regulated, a desirable nitrate-doped polypyrrole ion-selective membrane (PPy(NO3-)-ISM) and Au solid contact layer of anticipate surface morphology were obtained, and the performance of nitrate all-solid ion-selective electrodes (NS ISEs) was improved. It was found that the roughest PPy(NO3-)-ISM remarkably increases the actual contact surface area of the PPy(NO3-)-ISMs with nitrate solution, which leads to better adsorption of NO3- ions upon the PPy(NO3-)-ISMs, and produces a larger number of electrons. The most hydrophobic Au solid contact layer avoids the formation of the aqueous layer at the interface between the PPy(NO3-)-ISM and Au solid contact layer, and ensures unimpeded transporting of the produced electrons. The PPy-Au-NS ISE for polymerization duration 1800 s and at Au3+ concentration 2.5 mM of the electrolyte displays an optimal nitrate potential response, including a Nernstian slope of 54.0 mV/dec, LOD of 1.1 × 10-4 M, rapid average response time less than 1.9 s, and long-term stability of more than 5 weeks. This indicates that the PPy-Au-NS ISE is an effective working electrode for the electrochemical determination of NO3- concentration.
Collapse
Affiliation(s)
- Weizhuo Gao
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Weixuan Jing
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
- Chongqing Key Laboratory of Micro-Nano Systems and Smart Transduction, Chongqing Technology and Business University, Chongqing 400067, China
- Shandong Laboratory of Yantai Advanced Materials and Green Manufacturing, Yantai 265503, China
| | - Yanrui Du
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Zehao Li
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Pengcheng Liu
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Feng Han
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Libo Zhao
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
- Shandong Laboratory of Yantai Advanced Materials and Green Manufacturing, Yantai 265503, China
| | - Zhaochu Yang
- Chongqing Key Laboratory of Micro-Nano Systems and Smart Transduction, Chongqing Technology and Business University, Chongqing 400067, China
| | - Zhuangde Jiang
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| |
Collapse
|
2
|
Sun Y, Li D, Shi Y, Wang Z, Okeke SI, Yang L, Zhang W, Zhang Z, Shi Y, Xiao L. Application of 3D Printing Technology in Sensor Development for Water Quality Monitoring. SENSORS (BASEL, SWITZERLAND) 2023; 23:2366. [PMID: 36904570 PMCID: PMC10007434 DOI: 10.3390/s23052366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 02/12/2023] [Accepted: 02/13/2023] [Indexed: 06/18/2023]
Abstract
The development of sensors for water quality monitoring is crucial to protect water quality, aquatic biota and human health. Traditional sensor manufacturing methods have significant drawbacks, such as low fabrication freedom, limited material choice and expensive manufacturing cost. As a possible alternative method, 3D printing technologies are increasingly popular in sensor development due to their high versatility, fast fabrication/modification, powerful processing of different materials and ease of incorporation with other sensor systems. Surprisingly, a systematic review examining the application of 3D printing technology in water monitoring sensors has not yet been conducted. Here, we summarized the development history, market share and advantages/disadvantages of typical 3D printing techniques. Specifically focused on the 3D-printed sensor for water quality monitoring, we then reviewed the applications of 3D printing in the development of sensors' supporting platform, cell, sensing electrode as well as all-3D-printed sensors. The fabrication materials and processing, and the sensor's performances regarding detected parameters, response time and detection limit/sensitivity, were also compared and analyzed. Finally, the current drawbacks of 3D-printed water sensors and potential directions for future study were discussed. This review will substantially promote the understanding of 3D printing technology used in water sensor development and benefit the protection of water resources.
Collapse
Affiliation(s)
- Yifan Sun
- Department of Civil, Structural and Environmental Engineering, Trinity College Dublin, D02 PN40 Dublin, Ireland
| | - Dunzhu Li
- Department of Civil, Structural and Environmental Engineering, Trinity College Dublin, D02 PN40 Dublin, Ireland
| | - Yunhong Shi
- Department of Civil, Structural and Environmental Engineering, Trinity College Dublin, D02 PN40 Dublin, Ireland
| | - Zeena Wang
- Department of Civil, Structural and Environmental Engineering, Trinity College Dublin, D02 PN40 Dublin, Ireland
| | - Saviour I. Okeke
- Department of Civil, Structural and Environmental Engineering, Trinity College Dublin, D02 PN40 Dublin, Ireland
| | - Luming Yang
- Department of Civil, Structural and Environmental Engineering, Trinity College Dublin, D02 PN40 Dublin, Ireland
| | - Wen Zhang
- Department of Civil, Structural and Environmental Engineering, Trinity College Dublin, D02 PN40 Dublin, Ireland
| | - Zihan Zhang
- Department of Civil, Structural and Environmental Engineering, Trinity College Dublin, D02 PN40 Dublin, Ireland
| | - Yanqi Shi
- Department of Civil, Structural and Environmental Engineering, Trinity College Dublin, D02 PN40 Dublin, Ireland
| | - Liwen Xiao
- Department of Civil, Structural and Environmental Engineering, Trinity College Dublin, D02 PN40 Dublin, Ireland
- TrinityHaus, Trinity College Dublin, D02 PN40 Dublin, Ireland
| |
Collapse
|
3
|
Zhai J, Luo B, Li A, Dong H, Jin X, Wang X. Unlocking All-Solid Ion Selective Electrodes: Prospects in Crop Detection. SENSORS (BASEL, SWITZERLAND) 2022; 22:5541. [PMID: 35898054 PMCID: PMC9331676 DOI: 10.3390/s22155541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 07/20/2022] [Accepted: 07/21/2022] [Indexed: 06/15/2023]
Abstract
This paper reviews the development of all-solid-state ion-selective electrodes (ASSISEs) for agricultural crop detection. Both nutrient ions and heavy metal ions inside and outside the plant have a significant influence on crop growth. This review begins with the detection principle of ASSISEs. The second section introduces the key characteristics of ASSISE and demonstrates its feasibility in crop detection based on previous research. The third section considers the development of ASSISEs in the detection of corps internally and externally (e.g., crop nutrition, heavy metal pollution, soil salinization, N enrichment, and sensor miniaturization, etc.) and discusses the interference of the test environment. The suggestions and conclusions discussed in this paper may provide the foundation for additional research into ion detection for crops.
Collapse
Affiliation(s)
- Jiawei Zhai
- Research Center of Intelligent Equipment, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China; (J.Z.); (B.L.); (A.L.); (H.D.); (X.J.)
- College of Mechanical and Electrical Engineering, Fujian Agriculture and Forestry University, Fuzhou 350108, China
| | - Bin Luo
- Research Center of Intelligent Equipment, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China; (J.Z.); (B.L.); (A.L.); (H.D.); (X.J.)
| | - Aixue Li
- Research Center of Intelligent Equipment, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China; (J.Z.); (B.L.); (A.L.); (H.D.); (X.J.)
| | - Hongtu Dong
- Research Center of Intelligent Equipment, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China; (J.Z.); (B.L.); (A.L.); (H.D.); (X.J.)
| | - Xiaotong Jin
- Research Center of Intelligent Equipment, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China; (J.Z.); (B.L.); (A.L.); (H.D.); (X.J.)
| | - Xiaodong Wang
- Research Center of Intelligent Equipment, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China; (J.Z.); (B.L.); (A.L.); (H.D.); (X.J.)
| |
Collapse
|
4
|
Trojanowicz M, Pyszynska M. Flow-Injection Methods in Water Analysis-Recent Developments. Molecules 2022; 27:1410. [PMID: 35209198 PMCID: PMC8879103 DOI: 10.3390/molecules27041410] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 02/11/2022] [Accepted: 02/15/2022] [Indexed: 12/10/2022] Open
Abstract
Widespread demand for the analysis and control of water quality and supply for human activity and ecosystem sustainability has necessitated the continuous improvement of water analysis methods in terms of their reliability, efficiency, and costs. To satisfy these requirements, flow-injection analysis using different detection methods has successfully been developed in recent decades. This review, based on about 100 original research papers, presents the achievements in this field over the past ten years. Various methodologies for establishing flow-injection measurements are reviewed, together with microfluidics and portable systems. The developed applications mostly concern not only the determination of inorganic analytes but also the speciation analysis of different elements, and the determination of several total indices of water quality. Examples of the determination of organic residues (e.g., pesticides, phenolic compounds, and surfactants) in natural surface waters, seawater, groundwater, and drinking water have also been identified. Usually, changes in the format of manual procedures for flow-injection determination results in the improvement of various operational parameters, such as the limits of detection, the sampling rate, or selectivity in different matrices.
Collapse
Affiliation(s)
- Marek Trojanowicz
- Laboratory of Nuclear Analytical Methods, Institute of Nuclear Chemistry and Technology, Dorodna 16, 02-195 Warsaw, Poland;
- Department of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
| | - Marta Pyszynska
- Laboratory of Nuclear Analytical Methods, Institute of Nuclear Chemistry and Technology, Dorodna 16, 02-195 Warsaw, Poland;
| |
Collapse
|
5
|
Kościelniak P, Dębosz M, Wieczorek M, Migdalski J, Szufla M, Matoga D, Kochana J. The Use of an Acylhydrazone-Based Metal-Organic Framework in Solid-Contact Potassium-Selective Electrode for Water Analysis. MATERIALS 2022; 15:ma15020579. [PMID: 35057298 PMCID: PMC8781722 DOI: 10.3390/ma15020579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 12/16/2021] [Accepted: 01/10/2022] [Indexed: 01/27/2023]
Abstract
A solid-contact ion-selective electrode was developed for detecting potassium in environmental water. Two versions of a stable cadmium acylhydrazone-based metal organic framework, i.e., JUK-13 and JUK-13_H2O, were used for the construction of the mediation layer. The potentiometric and electrochemical characterizations of the proposed electrodes were carried out. The implementation of the JUK-13_H2O interlayer is shown to improve the potentiometric response and stability of measured potential. The electrode exhibits a good Nernstian slope (56.30 mV/decade) in the concentration range from 10−5 to 10−1 mol L−1 with a detection limit of 2.1 µmol L−1. The long-term potential stability shows a small drift of 0.32 mV h−1 over 67 h. The electrode displays a good selectivity comparable to ion-selective electrodes with the same membrane. The K-JUK-13_H2O-ISE was successfully applied for the determination of potassium in three certified reference materials of environmental water with great precision (RSD < 3.00%) and accuracy (RE < 3.00%).
Collapse
Affiliation(s)
- Paweł Kościelniak
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387 Kraków, Poland; (M.D.); (M.W.); (J.K.)
- Correspondence:
| | - Marek Dębosz
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387 Kraków, Poland; (M.D.); (M.W.); (J.K.)
| | - Marcin Wieczorek
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387 Kraków, Poland; (M.D.); (M.W.); (J.K.)
| | - Jan Migdalski
- Department of Analytical Chemistry and Biochemistry, Faculty of Materials and Ceramics, AGH University of Science and Technology, A. Mickiewicza 30, 30-059 Kraków, Poland;
| | - Monika Szufla
- Department of Inorganic Chemistry, Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387 Kraków, Poland; (M.S.); (D.M.)
| | - Dariusz Matoga
- Department of Inorganic Chemistry, Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387 Kraków, Poland; (M.S.); (D.M.)
| | - Jolanta Kochana
- Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387 Kraków, Poland; (M.D.); (M.W.); (J.K.)
| |
Collapse
|
6
|
Electrochemical Devices to Monitor Ionic Analytes for Healthcare and Industrial Applications. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10010022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Recent advances in electrochemical devices have sparked exciting opportunities in the healthcare, environment, and food industries. These devices can be fabricated at low costs and are capable of multiplex monitoring. This overcomes challenges presnted in traditional sensors for biomolecules and provides us a unique gateway toward comprehensive analyses. The advantages of electrochemical sensors are derived from their direct integration with electronics and their high selectivity along with sensitivity to sense a wide range of ionic analytes at an economical cost. This review paper aims to summarize recent innovations of a wide variety of electrochemical sensors for ionic analytes for health care and industrial applications. Many of these ionic analytes are important biomarkers to target for new diagnostic tools for medicine, food quality monitoring, and pollution detection. In this paper, we will examine various fabrication techniques, sensing mechanisms, and will also discuss various future opportunities in this research direction.
Collapse
|
7
|
Glasco DL, Ho NHB, Mamaril AM, Bell JG. 3D Printed Ion-Selective Membranes and Their Translation into Point-of-Care Sensors. Anal Chem 2021; 93:15826-15831. [PMID: 34812620 DOI: 10.1021/acs.analchem.1c03762] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
This technical note describes a method for fabricating ion-selective membranes (ISMs) for use in potentiometric sensing by using 3D printing technology. Here, we demonstrate the versatility of this approach by fabricating ISMs and investigating their performance in both liquid-contact and solid-contact ion-selective electrode (ISE) configurations. Using 3D printed ISMs resulted in highly stable (drift of ∼17 μV/h) and highly reproducible (<1 mV deviation) measurements. Furthermore, we show the seamless translation of these membranes into reliable, carbon fiber- and paper-based potentiometric sensors for applications at the point-of-care. To highlight the modifiability of this approach, we fabricated sensors for bilirubin, an important biomarker of liver health; benzalkonium, a common preservative used in the pharmaceutical industry; and potassium, an important blood electrolyte. The ability to mass produce sensors using 3D printing is an attractive advantage over conventional methods, while also decreasing the time and cost associated with sensor fabrication.
Collapse
Affiliation(s)
- Dalton L Glasco
- Department of Chemistry, Washington State University, Pullman, Washington 99163, United States
| | - Nguyen H B Ho
- Department of Chemistry, Washington State University, Pullman, Washington 99163, United States
| | - Art Matthew Mamaril
- Department of Chemistry, Washington State University, Pullman, Washington 99163, United States
| | - Jeffrey G Bell
- Department of Chemistry, Washington State University, Pullman, Washington 99163, United States
| |
Collapse
|
8
|
Automated liquid-liquid microextraction and determination of sulfonamides in urine samples based on Schiff bases formation in natural deep eutectic solvent media. Talanta 2021; 234:122660. [PMID: 34364468 DOI: 10.1016/j.talanta.2021.122660] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 06/22/2021] [Accepted: 06/24/2021] [Indexed: 12/13/2022]
Abstract
In this work, an automated liquid-liquid microextraction procedure for the determination of sulfonamides (sulfamethoxazole, sulfamethazine and sulfapyridine) in urine samples using natural deep eutectic solvent is presented for the first time. The mechanism for extraction of sulfonamides was based on the formation of colored Schiff bases in the presence of vanillin, which acted as a derivatization reagent and precursor of natural deep eutectic solvent (an extractant). In this procedure, thymol was used as both media for Schiff bases formation and as a second precursor of the natural deep eutectic solvent. The formation of the Schiff bases was confirmed by mass spectrometry. A Lab-In-Syringe concept was applied for the automation of the microextraction procedure. The procedure involved mixing the sample and natural deep eutectic solvent into a syringe of a flow system, formation and microextraction of colored Schiff base followed by UV-Vis detection. Under optimal automated conditions the limits of detection, calculated from a blank test based on 3s (sigma) were 0.06, 0.1, and 0.06 mg L-1 for sulfapyridine, sulfamethoxazole and sulfamethazine. The proposed automated procedure permitted the routine determination of one drug (sulfamethoxazole, sulfamethazine or sulfapyridine) in urine samples to be achieved in less than 10 min.
Collapse
|
9
|
Dębosz M, Kozma J, Porada R, Wieczorek M, Paluch J, Gyurcsányi RE, Migdalski J, Kościelniak P. 3D-printed manifold integrating solid contact ion-selective electrodes for multiplexed ion concentration measurements in urine. Talanta 2021; 232:122491. [PMID: 34074448 DOI: 10.1016/j.talanta.2021.122491] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 04/26/2021] [Accepted: 04/29/2021] [Indexed: 01/26/2023]
Abstract
Urinalysis is a simple and non-invasive approach for the diagnosis and monitoring of various health disorders. While urinalysis is predominantly confined to clinical laboratories the non-invasive sample collection makes it applicable in wide range of settings outside of central laboratory confinements. In this respect, 3D printed devices integrating sensors for measuring multiple parameters may be one of the most viable approaches to ensure cost-effectiveness for widespread use. Here we evaluated such a system for the multiplexed determination of sodium, potassium and calcium ions in urine samples with ion-selective electrodes based on state of the art octadecylamine-functionalized multi-walled carbon nanotube (OD-MWCNT) solid contacts. The electrodes were tested in the clinically relevant concentration range, i.e. ca. 10-4 - 10-1 mol L-1 and were proven to have Nernstian responses under flow injection conditions. The applicability of the 3D printed flow manifold was investigated through the analysis of synthetic samples and two certified reference materials. The obtained results confirm the suitability of the proposed system for multiplexed ion analysis in urine.
Collapse
Affiliation(s)
- Marek Dębosz
- Jagiellonian University in Krakow, Faculty of Chemistry, Department of Analytical Chemistry, Ul. Gronostajowa 2, Krakow, Poland.
| | - József Kozma
- Budapest University of Technology and Economics, Department of Inorganic and Analytical Chemistry, BME "Lendület" Chemical Nanosensors Research Group, Szt. Gellért Tér 4, H-1111, Budapest, Hungary
| | - Radosław Porada
- AGH-University of Science and Technology in Cracow, Faculty of Materials Science and Ceramics, Department of Analytical Chemistry and Biochemistry, Al. Mickiewicza 30, Kraków, Poland
| | - Marcin Wieczorek
- Jagiellonian University in Krakow, Faculty of Chemistry, Department of Analytical Chemistry, Ul. Gronostajowa 2, Krakow, Poland
| | - Justyna Paluch
- Jagiellonian University in Krakow, Faculty of Chemistry, Department of Analytical Chemistry, Ul. Gronostajowa 2, Krakow, Poland
| | - Róbert E Gyurcsányi
- Budapest University of Technology and Economics, Department of Inorganic and Analytical Chemistry, BME "Lendület" Chemical Nanosensors Research Group, Szt. Gellért Tér 4, H-1111, Budapest, Hungary
| | - Jan Migdalski
- AGH-University of Science and Technology in Cracow, Faculty of Materials Science and Ceramics, Department of Analytical Chemistry and Biochemistry, Al. Mickiewicza 30, Kraków, Poland
| | - Paweł Kościelniak
- Jagiellonian University in Krakow, Faculty of Chemistry, Department of Analytical Chemistry, Ul. Gronostajowa 2, Krakow, Poland
| |
Collapse
|