1
|
Mruthunjaya AKV, Torriero AAJ. Electrochemical Monitoring in Anticoagulation Therapy. Molecules 2024; 29:1453. [PMID: 38611733 PMCID: PMC11012951 DOI: 10.3390/molecules29071453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 03/16/2024] [Accepted: 03/22/2024] [Indexed: 04/14/2024] Open
Abstract
The process of blood coagulation, wherein circulating blood transforms into a clot in response to an internal or external injury, is a critical physiological mechanism. Monitoring this coagulation process is vital to ensure that blood clotting neither occurs too rapidly nor too slowly. Anticoagulants, a category of medications designed to prevent and treat blood clots, require meticulous monitoring to optimise dosage, enhance clinical outcomes, and minimise adverse effects. This review article delves into the various stages of blood coagulation, explores commonly used anticoagulants and their targets within the coagulation enzyme system, and emphasises the electrochemical methods employed in anticoagulant testing. Electrochemical sensors for anticoagulant monitoring are categorised into two types. The first type focuses on assays measuring thrombin activity via electrochemical techniques. The second type involves modified electrode surfaces that either directly measure the redox behaviours of anticoagulants or monitor the responses of standard redox probes in the presence of these drugs. This review comprehensively lists different electrode compositions and their detection and quantification limits. Additionally, it discusses the potential of employing a universal calibration plot to replace individual drug-specific calibrations. The presented insights are anticipated to significantly contribute to the sensor community's efforts in this field.
Collapse
Affiliation(s)
| | - Angel A. J. Torriero
- School of Life and Environmental Sciences, Deakin University, Burwood 3125, Australia
| |
Collapse
|
2
|
Larcher R, Lottelier M, Badiou S, Dupuy AM, Bargnoux AS, Cristol JP. Analytical Performances of the Novel i-STAT Alinity Point-of-Care Analyzer. Diagnostics (Basel) 2023; 13:diagnostics13020297. [PMID: 36673107 PMCID: PMC9857650 DOI: 10.3390/diagnostics13020297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Revised: 12/21/2022] [Accepted: 01/08/2023] [Indexed: 01/15/2023] Open
Abstract
Many Point-of-Care devices have been released over the past decade. However, data regarding their analytical performances in real-world situations remains scarce. Herein, we aimed to assess the analytical performances of the i-STAT Alinity system. We conducted an analytical performances study with the i-STAT Alinity device using cartridges CG4+ (pH, Pco2, Po2, lactate, bicarbonate and base excess); CHEM8+ (Na, K, Cl, ionized Ca, urea, creatinine, glucose, hematocrit and hemoglobin) and PT/INR (prothrombin time and international normalized ratio). We assessed the imprecision and compared the results to those obtained on existing instruments in the central laboratory. We found that the within-lab coefficients of variation (CV) were very low (<2%) or low (2−5%), except for creatinine and PT (CV = 5.2% and CV = 6.3%, respectively). For almost all the parameters, the results were strongly (R2 = 90−95%) or very strongly (R2 > 95%) correlated with those of the existing laboratory instruments, and the biases were very low (<2%) or low (2−5%). However, correlations of the PT and INR measurements with existing instruments were lower (R2 = 86.0% and 89.7%), and biases in the Po2 (7.9%), creatinine (5.4%) and PT (−6.6%) measurements were higher. The i-STAT Alinity appeared as a convenient device for measurements of numerous parameters. However, clinicians should interpret Po2, creatinine and PT results with caution.
Collapse
Affiliation(s)
- Romaric Larcher
- Biochemistry and Hormonology Department, Montpellier University Hospital, PhyMedExp (Physiology and Experimental Medicine), INSERM (French Institute of Health and Medical Research), CNRS (French National Centre for Scientific Research), University of Montpellier, 34000 Montpellier, France
- Infectious and Tropical Diseases Department, Nimes University Hospital, 30000 Nimes, France
- Correspondence: ; Tel.: +33-466-68-41-49
| | - Maxence Lottelier
- Biochemistry and Hormonology Department, Montpellier University Hospital, 34000 Montpellier, France
| | - Stephanie Badiou
- Biochemistry and Hormonology Department, Montpellier University Hospital, PhyMedExp (Physiology and Experimental Medicine), INSERM (French Institute of Health and Medical Research), CNRS (French National Centre for Scientific Research), University of Montpellier, 34000 Montpellier, France
| | - Anne-Marie Dupuy
- Biochemistry and Hormonology Department, Montpellier University Hospital, 34000 Montpellier, France
| | - Anne-Sophie Bargnoux
- Biochemistry and Hormonology Department, Montpellier University Hospital, PhyMedExp (Physiology and Experimental Medicine), INSERM (French Institute of Health and Medical Research), CNRS (French National Centre for Scientific Research), University of Montpellier, 34000 Montpellier, France
| | - Jean-Paul Cristol
- Biochemistry and Hormonology Department, Montpellier University Hospital, PhyMedExp (Physiology and Experimental Medicine), INSERM (French Institute of Health and Medical Research), CNRS (French National Centre for Scientific Research), University of Montpellier, 34000 Montpellier, France
| |
Collapse
|
3
|
Bodington R, Kassianides X, Bhandari S. Point-of-care testing technologies for the home in chronic kidney disease: a narrative review. Clin Kidney J 2021; 14:2316-2331. [PMID: 34751234 PMCID: PMC8083235 DOI: 10.1093/ckj/sfab080] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Indexed: 01/09/2023] Open
Abstract
Point-of-care testing (POCT) performed by the patient at home, paired with eHealth technologies, offers a wealth of opportunities to develop individualized, empowering clinical pathways. The non-dialysis-dependent chronic kidney disease (CKD) patient who is at risk of or may already be suffering from a number of the associated complications of CKD represents an ideal patient group for the development of such initiatives. The current coronavirus disease 2019 pandemic and drive towards shielding vulnerable individuals have further highlighted the need for home testing pathways. In this narrative review we outline the evidence supporting remote patient management and the various technologies in use in the POCT setting. We then review the devices currently available for use in the home by patients in five key areas of renal medicine: anaemia, biochemical, blood pressure (BP), anticoagulation and diabetes monitoring. Currently there are few devices and little evidence to support the use of home POCT in CKD. While home testing in BP, anticoagulation and diabetes monitoring is relatively well developed, the fields of anaemia and biochemical POCT are still in their infancy. However, patients' attitudes towards eHealth and home POCT are consistently positive and physicians also find this care highly acceptable. The regulatory and translational challenges involved in the development of new home-based care pathways are significant. Pragmatic and adaptable trials of a hybrid effectiveness-implementation design, as well as continued technological POCT device advancement, are required to deliver these innovative new pathways that our patients desire and deserve.
Collapse
Affiliation(s)
- Richard Bodington
- Sheffield Kidney Institute, Northern General Hospital, Sheffield, UK
| | | | - Sunil Bhandari
- Department of Renal Research, Hull Royal Infirmary, Hull, UK
| |
Collapse
|
4
|
Evaluation of the Accuracy of the LumiraDx INR Test Using Patients in Receipt of Phenprocoumon Anticoagulation Therapy. POINT OF CARE 2020. [DOI: 10.1097/poc.0000000000000207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
5
|
Mohammadi Aria M, Erten A, Yalcin O. Technology Advancements in Blood Coagulation Measurements for Point-of-Care Diagnostic Testing. Front Bioeng Biotechnol 2019; 7:395. [PMID: 31921804 PMCID: PMC6917661 DOI: 10.3389/fbioe.2019.00395] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Accepted: 11/21/2019] [Indexed: 12/24/2022] Open
Abstract
In recent years, blood coagulation monitoring has become crucial to diagnosing causes of hemorrhages, developing anticoagulant drugs, assessing bleeding risk in extensive surgery procedures and dialysis, and investigating the efficacy of hemostatic therapies. In this regard, advanced technologies such as microfluidics, fluorescent microscopy, electrochemical sensing, photoacoustic detection, and micro/nano electromechanical systems (MEMS/NEMS) have been employed to develop highly accurate, robust, and cost-effective point of care (POC) devices. These devices measure electrochemical, optical, and mechanical parameters of clotting blood. Which can be correlated to light transmission/scattering, electrical impedance, and viscoelastic properties. In this regard, this paper discusses the working principles of blood coagulation monitoring, physical and sensing parameters in different technologies. In addition, we discussed the recent progress in developing nanomaterials for blood coagulation detection and treatments which opens up new area of controlling and monitoring of coagulation at the same time in the future. Moreover, commercial products, future trends/challenges in blood coagulation monitoring including novel anticoagulant therapies, multiplexed sensing platforms, and the application of artificial intelligence in diagnosis and monitoring have been included.
Collapse
Affiliation(s)
| | - Ahmet Erten
- Department of Electronics and Communication Engineering, Istanbul Technical University, Istanbul, Turkey
| | - Ozlem Yalcin
- Graduate School of Biomedical Sciences and Engineering, Koc University, Sariyer, Turkey
- Department of Physiology, Koc University School of Medicine, Koc University, Sariyer, Turkey
| |
Collapse
|