1
|
Chen L, Li D, Liu X, Xie Y, Shan J, Huang H, Yu X, Chen Y, Zheng W, Li Z. Point-of-Care Blood Coagulation Assay Based on Dynamic Monitoring of Blood Viscosity Using Droplet Microfluidics. ACS Sens 2022; 7:2170-2177. [PMID: 35537208 DOI: 10.1021/acssensors.1c02360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Monitoring of the coagulation function has applications in many clinical settings. Routine coagulation assays in the clinic are sample-consuming and slow in turnaround. Microfluidics provides the opportunity to develop coagulation assays that are applicable in point-of-care settings, but reported works required bulky sample pumping units or costly data acquisition instruments. In this work, we developed a microfluidic coagulation assay with a simple setup and easy operation. The device continuously generated droplets of blood sample and buffer mixture and reported the temporal development of blood viscosity during coagulation based on the color appearance of the resultant droplets. We characterized the relationship between blood viscosity and color appearance of the droplets and performed experiments to validate the assay results. In addition, we developed a prototype analyzer equipped with simple fluid pumping and economical imaging module and obtained similar assay measurements. This assay showed great potential to be developed into a point-of-care coagulation test with practical impact.
Collapse
Affiliation(s)
- Linzhe Chen
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.,Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Donghao Li
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.,Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Xinyu Liu
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.,Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.,Faculty of Information Technology, Collaborative Laboratory for Intelligent Science and Systems and State Key Laboratory of Quality Research in Chinese Medicines, Macau University of Science and Technology, Macao 999078, China
| | - Yihan Xie
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.,Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Jieying Shan
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.,Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Haofan Huang
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.,Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Xiaxia Yu
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.,Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Yudan Chen
- Department of Laboratory Medicine, Shenzhen University General Hospital, Shenzhen 518055, China
| | - Weidong Zheng
- Department of Laboratory Medicine, Shenzhen University General Hospital, Shenzhen 518055, China
| | - Zida Li
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.,Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| |
Collapse
|
2
|
Abstract
Blood cell analysis is essential for the diagnosis and identification of hematological malignancies. The use of digital microscopy systems has been extended in clinical laboratories. Super-resolution microscopy (SRM) has attracted wide attention in the medical field due to its nanoscale spatial resolution and high sensitivity. It is considered to be a potential method of blood cell analysis that may have more advantages than traditional approaches such as conventional optical microscopy and hematology analyzers in certain examination projects. In this review, we firstly summarize several common blood cell analysis technologies in the clinic, and analyze the advantages and disadvantages of these technologies. Then, we focus on the basic principles and characteristics of three representative SRM techniques, as well as the latest advances in these techniques for blood cell analysis. Finally, we discuss the developmental trend and possible research directions of SRM, and provide some discussions on further development of technologies for blood cell analysis.
Collapse
|
3
|
Li D, Liu X, Chai Y, Shan J, Xie Y, Liang Y, Huang S, Zheng W, Li Z. Point-of-care blood coagulation assay enabled by printed circuit board-based digital microfluidics. LAB ON A CHIP 2022; 22:709-716. [PMID: 35050293 DOI: 10.1039/d1lc00981h] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The monitoring of coagulation function has great implications in many clinical settings. However, existing coagulation assays are simplex, sample-consuming, and slow in turnaround, making them less suitable for point-of-care testing. In this work, we developed a novel blood coagulation assay that simultaneously assesses both the tendency of clotting and the stiffness of the resultant clot using printed circuit board (PCB)-based digital microfluidics. A drop of blood was actuated to move back and forth on the PCB electrode array, until the motion winded down as the blood coagulated and became thicker. The velocity tracing and the deformation of the clot were calculated via image analysis to reflect the coagulation progression and the clot stiffness, respectively. We investigated the effect of different hardware and biochemical settings on the assay results. To validate the assay, we performed assays on blood samples with hypo- and hyper-coagulability, and the results confirmed the assay's capability in distinguishing different blood samples. We then examined the correlation between the measured metrics in our assays and standard coagulation assays, namely prothrombin time and fibrinogen level, and the high correlation supported the clinical relevance of our assay. We envision that this method would serve as a powerful point-of-care coagulation testing method.
Collapse
Affiliation(s)
- Donghao Li
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Xinyu Liu
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
- Faculty of Information Technology, Collaborative Laboratory for Intelligent Science and Systems and State Key Laboratory of Quality Research in Chinese Medicines, Macau University of Science and Technology, Macao 999078, China
| | - Yujuan Chai
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Jieying Shan
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Yihan Xie
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Yong Liang
- Faculty of Information Technology, Collaborative Laboratory for Intelligent Science and Systems and State Key Laboratory of Quality Research in Chinese Medicines, Macau University of Science and Technology, Macao 999078, China
| | - Susu Huang
- Department of Laboratory Medicine, Shenzhen University General Hospital, Shenzhen 518055, China
| | - Weidong Zheng
- Department of Laboratory Medicine, Shenzhen University General Hospital, Shenzhen 518055, China
| | - Zida Li
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| |
Collapse
|
4
|
Huang L, Liu X, Ou Y, Huang H, Zhang X, Wang Y, Liang Y, Yu X, Zheng W, Zhang H, Li Z. Microengineered Flexural Post Rings for Effective Blood Sample Fencing and High-Throughput Measurement of Clot Retraction Force. ACS Sens 2020; 5:3949-3955. [PMID: 33197179 DOI: 10.1021/acssensors.0c01596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
During blood clotting, clot retraction alters its mechanical properties and critically affects hemostasis. Despite that, existing clot retraction assays hold limitations such as large footprint and low throughput. In this work, we report the design of flexural post rings for a miniaturized assay of clot retraction force (CRF) with high throughput. Leveraging surface tensions, the post rings hold blood samples in a highly reproducible fashion while simultaneously serving as cantilever beams to measure the CRF. We investigated the effect on the device performance of major parameters, namely, surface hydrophobicity, post number, and post stiffness. We then tested the devices using 14 patient samples and revealed the correlation between CRF and fibrinogen levels. We further implemented an automated liquid handler and developed a high-throughput platform for clot retraction assay. The device's small sample consumption, simple operation, and good compatibility with existing automation facilities make it a promising high-throughput clot retraction assay.
Collapse
Affiliation(s)
- Lanzhu Huang
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Xinyu Liu
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
- Faculty of Information Technology, Collaborative Laboratory for Intelligent Science and Systems and State Key Laboratory of Quality Research in Chinese Medicines, Macau University of Science and Technology, Macao 999078, China
| | - Yuanbin Ou
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Haofan Huang
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Xia Zhang
- Department of Laboratory Medicine, Shenzhen University General Hospital, Shenzhen 518055, China
| | - Yize Wang
- Department of Mechanical and Process Engineering, ETH Zurich, 8092 Zurich, Switzerland
| | - Yong Liang
- Faculty of Information Technology, Collaborative Laboratory for Intelligent Science and Systems and State Key Laboratory of Quality Research in Chinese Medicines, Macau University of Science and Technology, Macao 999078, China
| | - Xiaxia Yu
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Weidong Zheng
- Department of Laboratory Medicine, Shenzhen University General Hospital, Shenzhen 518055, China
| | - Huisheng Zhang
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Zida Li
- Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| |
Collapse
|
5
|
Godino N, Pfisterer F, Gerling T, Guernth-Marschner C, Duschl C, Kirschbaum M. Combining dielectrophoresis and computer vision for precise and fully automated single-cell handling and analysis. LAB ON A CHIP 2019; 19:4016-4020. [PMID: 31746875 DOI: 10.1039/c9lc00800d] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
With the advent of single-cell technologies comes the necessity for efficient protocols to process single cells. We combine dielectrophoresis with open source computer vision programming to automatically control the trajectories of single cells inside a microfluidic device. Using real-time image analysis, individual cells are automatically selected, isolated and spatially arranged.
Collapse
Affiliation(s)
- Neus Godino
- Fraunhofer IZI-BB, Am Muehlenberg 13, 14476 Potsdam, Germany.
| | - Felix Pfisterer
- Fraunhofer IZI-BB, Am Muehlenberg 13, 14476 Potsdam, Germany.
| | - Tobias Gerling
- Fraunhofer IZI-BB, Am Muehlenberg 13, 14476 Potsdam, Germany.
| | | | - Claus Duschl
- Fraunhofer IZI-BB, Am Muehlenberg 13, 14476 Potsdam, Germany.
| | | |
Collapse
|
6
|
van der Vlies AJ, Barua N, Nieves-Otero PA, Platt TG, Hansen RR. On Demand Release and Retrieval of Bacteria from Microwell Arrays Using Photodegradable Hydrogel Membranes. ACS APPLIED BIO MATERIALS 2018; 2:266-276. [DOI: 10.1021/acsabm.8b00592] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- André J. van der Vlies
- Chemical Engineering Department, Kansas State University, 1701A Platt Street, Manhattan, Kansas 66506, United States
| | - Niloy Barua
- Chemical Engineering Department, Kansas State University, 1701A Platt Street, Manhattan, Kansas 66506, United States
| | - Priscila A. Nieves-Otero
- Division of Biology, Kansas State University, 1717 Claflin Road, Manhattan, Kansas 66506, United States
| | - Thomas G. Platt
- Division of Biology, Kansas State University, 1717 Claflin Road, Manhattan, Kansas 66506, United States
| | - Ryan R. Hansen
- Chemical Engineering Department, Kansas State University, 1701A Platt Street, Manhattan, Kansas 66506, United States
| |
Collapse
|
7
|
Ungson Y, Burtseva L, Garcia-Curiel ER, Valdez Salas B, Flores-Rios BL, Werner F, Petranovskii V. Filling of Irregular Channels with Round Cross-Section: Modeling Aspects to Study the Properties of Porous Materials. MATERIALS 2018; 11:ma11101901. [PMID: 30301133 PMCID: PMC6213190 DOI: 10.3390/ma11101901] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/17/2018] [Revised: 09/25/2018] [Accepted: 09/27/2018] [Indexed: 12/28/2022]
Abstract
The filling of channels in porous media with particles of a material can be interpreted in a first approximation as a packing of spheres in cylindrical recipients. Numerous studies on micro- and nanoscopic scales show that they are, as a rule, not ideal cylinders. In this paper, the channels, which have an irregular shape and a circular cross-section, as well as the packing algorithms are investigated. Five patterns of channel shapes are detected to represent any irregular porous structures. A novel heuristic packing algorithm for monosized spheres and different irregularities is proposed. It begins with an initial configuration based on an fcc unit cell and the subsequent densification of the obtained structure by shaking and gravity procedures. A verification of the algorithm was carried out for nine sinusoidal axisymmetric channels with different Dmin/Dmax ratio by MATLAB® simulations, reaching a packing fraction of at least 0.67 (for sphere diameters of 5%Dmin or less), superior to a random close packing density. The maximum packing fraction was 73.01% for a channel with a ratio of Dmin/Dmax = 0.1 and a sphere size of 5%Dmin. For sphere diameters of 50%Dmin or larger, it was possible to increase the packing factor after applying shaking and gravity movements.
Collapse
Affiliation(s)
- Yamel Ungson
- Instituto de Ingeniería, Universidad Autónoma de Baja California, Calle de la Normal S/N, Col. Insurgentes Este, Mexicali 21270, Mexico.
| | - Larysa Burtseva
- Instituto de Ingeniería, Universidad Autónoma de Baja California, Calle de la Normal S/N, Col. Insurgentes Este, Mexicali 21270, Mexico.
| | - Edwin R Garcia-Curiel
- Instituto de Ingeniería, Universidad Autónoma de Baja California, Calle de la Normal S/N, Col. Insurgentes Este, Mexicali 21270, Mexico.
| | - Benjamin Valdez Salas
- Instituto de Ingeniería, Universidad Autónoma de Baja California, Calle de la Normal S/N, Col. Insurgentes Este, Mexicali 21270, Mexico.
| | - Brenda L Flores-Rios
- Instituto de Ingeniería, Universidad Autónoma de Baja California, Calle de la Normal S/N, Col. Insurgentes Este, Mexicali 21270, Mexico.
| | - Frank Werner
- Institut für Mathematische Optimierung, Otto-von-Guericke-Universität Magdeburg, Universitätsplatz 2, 39106 Magdeburg, Germany.
| | - Vitalii Petranovskii
- Centro de Nanociencias y Nanotecnología, Universidad Nacional Autónoma de México, Carretera Tijuana-Ensenada km107, Playitas, Ensenada 22860, Mexico.
| |
Collapse
|
8
|
Yap BK, M Soair SN, Talik NA, Lim WF, Mei I L. Potential Point-of-Care Microfluidic Devices to Diagnose Iron Deficiency Anemia. SENSORS (BASEL, SWITZERLAND) 2018; 18:E2625. [PMID: 30103424 PMCID: PMC6111990 DOI: 10.3390/s18082625] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Revised: 07/18/2018] [Accepted: 07/18/2018] [Indexed: 12/20/2022]
Abstract
Over the past 20 years, rapid technological advancement in the field of microfluidics has produced a wide array of microfluidic point-of-care (POC) diagnostic devices for the healthcare industry. However, potential microfluidic applications in the field of nutrition, specifically to diagnose iron deficiency anemia (IDA) detection, remain scarce. Iron deficiency anemia is the most common form of anemia, which affects billions of people globally, especially the elderly, women, and children. This review comprehensively analyzes the current diagnosis technologies that address anemia-related IDA-POC microfluidic devices in the future. This review briefly highlights various microfluidics devices that have the potential to detect IDA and discusses some commercially available devices for blood plasma separation mechanisms. Reagent deposition and integration into microfluidic devices are also explored. Finally, we discuss the challenges of insights into potential portable microfluidic systems, especially for remote IDA detection.
Collapse
Affiliation(s)
- Boon Kar Yap
- Electronics and Communication Department, College of Engineering, Universiti Tenaga Nasional, KM-7 Jalan Uniten-Ikram, 43000 Kajang, Selangor, Malaysia.
| | - Siti Nur'Arifah M Soair
- Electronics and Communication Department, College of Engineering, Universiti Tenaga Nasional, KM-7 Jalan Uniten-Ikram, 43000 Kajang, Selangor, Malaysia.
| | - Noor Azrina Talik
- Electronics and Communication Department, College of Engineering, Universiti Tenaga Nasional, KM-7 Jalan Uniten-Ikram, 43000 Kajang, Selangor, Malaysia.
- Institute of Power Electronics (IPE), College of Engineering, Universiti Tenaga Nasional, KM-7 Jalan Uniten-Ikram, 43000 Kajang, Selangor, Malaysia.
| | - Wai Feng Lim
- Integrative Pharmacogenomics Institute (iPROMISE), Universiti Teknologi MARA Selangor, Puncak Alam Campus, 42300 Bandar Puncak Alam, Selangor, Malaysia.
| | - Lai Mei I
- Department of Pathology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia.
| |
Collapse
|
9
|
Li Z, Wang Y, Xue X, McCracken B, Ward K, Fu J. Carbon Nanotube Strain Sensor Based Hemoretractometer for Blood Coagulation Testing. ACS Sens 2018; 3:670-676. [PMID: 29485284 PMCID: PMC6223013 DOI: 10.1021/acssensors.7b00971] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Coagulation monitoring is essential for perioperative care and thrombosis treatment. However, existing assays for coagulation monitoring have limitations such as a large footprint and complex setup. In this work, we developed a miniaturized device for point-of-care blood coagulation testing by measuring dynamic clot retraction force development during blood clotting. In this device, a blood drop was localized between a protrusion and a flexible force-sensing beam to measure clot retraction force. The beam was featured with micropillar arrays to assist the deposition of carbon nanotube films, which served as a strain sensor to achieve label-free electrical readout of clot retraction force in real time. We characterized mechanical and electrical properties of the force-sensing beam and optimized its design. We further demonstrated that this blood coagulation monitoring device could obtain results that were consistent with those using an imaging method and that the device was capable of differentiating blood samples with different coagulation profiles. Owing to its low fabrication cost, small size, and low consumption of blood samples, the blood coagulation testing device using carbon nanotube strain sensors holds great potential as a point-of-care tool for future coagulation monitoring.
Collapse
Affiliation(s)
- Zida Li
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Yize Wang
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Xufeng Xue
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Brendan McCracken
- Department of Emergency Medicine, University of Michigan Medical School, Ann Arbor, Michigan 48109, USA
- Michigan Center for Integrative Research in Critical Care, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Kevin Ward
- Department of Emergency Medicine, University of Michigan Medical School, Ann Arbor, Michigan 48109, USA
- Michigan Center for Integrative Research in Critical Care, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Jianping Fu
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
- Michigan Center for Integrative Research in Critical Care, University of Michigan, Ann Arbor, Michigan 48109, USA
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
- Department of Cell and Developmental Biology, University of Michigan Medical School, Ann Arbor, Michigan 48109, USA
| |
Collapse
|
10
|
Li Z, Li X, McCracken B, Shao Y, Ward K, Fu J. A Miniaturized Hemoretractometer for Blood Clot Retraction Testing. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2016; 12:3926-34. [PMID: 27248117 PMCID: PMC4980575 DOI: 10.1002/smll.201600274] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2016] [Revised: 03/16/2016] [Indexed: 05/13/2023]
Abstract
Blood coagulation is a critical hemostatic process that must be properly regulated to maintain a delicate balance between bleeding and clotting. Disorders of blood coagulation can expose patients to the risk of either bleeding disorders or thrombotic diseases. Coagulation diagnostics using whole blood is very promising for assessing the complexity of the coagulation system and for global measurements of hemostasis. Despite the clinic values that existing whole blood coagulation tests have demonstrated, these systems have significant limitations that diminish their potential for point-of-care applications. Here, recent advancements in device miniaturization using functional soft materials are leveraged to develop a miniaturized clot retraction force assay device termed mHemoRetractoMeter (mHRM). The mHRM is capable of precise measurements of dynamic clot retraction forces in real time using minute amounts of whole blood. To further demonstrate the clinical utility of the mHRM, systematic studies are conducted using the mHRM to examine the effects of assay temperature, treatments of clotting agents, and pro- and anti-coagulant drugs on clot retraction force developments of whole blood samples. The mHRM's low fabrication cost, small size, and consumption of only minute amounts of blood samples make the technology promising as a point-of-care tool for future coagulation monitoring.
Collapse
Affiliation(s)
- Zida Li
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Xiang Li
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Brendan McCracken
- Department of Emergency Medicine, University of Michigan, Ann Arbor, Michigan 48109, USA, Michigan Center for Integrative Research in Critical Care, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Yue Shao
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Kevin Ward
- Department of Emergency Medicine, University of Michigan, Ann Arbor, Michigan 48109, USA, Michigan Center for Integrative Research in Critical Care, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Jianping Fu
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA, Michigan Center for Integrative Research in Critical Care, University of Michigan, Ann Arbor, Michigan 48109, USA, Department of Biomedical Engineering, Department of Cell and Developmental Biology, University of Michigan, Ann Arbor, Michigan 48109, USA
| |
Collapse
|
11
|
Abstract
The combination of microbial engineering and microfluidics is synergistic in nature. For example, microfluidics is benefiting from the outcome of microbial engineering and many reported point-of-care microfluidic devices employ engineered microbes as functional parts for the microsystems. In addition, microbial engineering is facilitated by various microfluidic techniques, due to their inherent strength in high-throughput screening and miniaturization. In this review article, we firstly examine the applications of engineered microbes for toxicity detection, biosensing, and motion generation in microfluidic platforms. Secondly, we look into how microfluidic technologies facilitate the upstream and downstream processes of microbial engineering, including DNA recombination, transformation, target microbe selection, mutant characterization, and microbial function analysis. Thirdly, we highlight an emerging concept in microbial engineering, namely, microbial consortium engineering, where the behavior of a multicultural microbial community rather than that of a single cell/species is delineated. Integrating the disciplines of microfluidics and microbial engineering opens up many new opportunities, for example in diagnostics, engineering of microbial motors, development of portable devices for genetics, high throughput characterization of genetic mutants, isolation and identification of rare/unculturable microbial species, single-cell analysis with high spatio-temporal resolution, and exploration of natural microbial communities.
Collapse
Affiliation(s)
- Songzi Kou
- Department of Chemical and Biomolecular Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong.
| | - Danhui Cheng
- Division of Biomedical Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - Fei Sun
- Department of Chemical and Biomolecular Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong.
| | - I-Ming Hsing
- Department of Chemical and Biomolecular Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong. and Division of Biomedical Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| |
Collapse
|
12
|
Kang YJ, Ha YR, Lee SJ. Deformability measurement of red blood cells using a microfluidic channel array and an air cavity in a driving syringe with high throughput and precise detection of subpopulations. Analyst 2015; 141:319-30. [PMID: 26616556 DOI: 10.1039/c5an01988e] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Red blood cell (RBC) deformability has been considered a potential biomarker for monitoring pathological disorders. High throughput and detection of subpopulations in RBCs are essential in the measurement of RBC deformability. In this paper, we propose a new method to measure RBC deformability by evaluating temporal variations in the average velocity of blood flow and image intensity of successively clogged RBCs in the microfluidic channel array for specific time durations. In addition, to effectively detect differences in subpopulations of RBCs, an air compliance effect is employed by adding an air cavity into a disposable syringe. The syringe was equally filled with a blood sample (V(blood) = 0.3 mL, hematocrit = 50%) and air (V(air) = 0.3 mL). Owing to the air compliance effect, blood flow in the microfluidic device behaved transiently depending on the fluidic resistance in the microfluidic device. Based on the transient behaviors of blood flows, the deformability of RBCs is quantified by evaluating three representative parameters, namely, minimum value of the average velocity of blood flow, clogging index, and delivered blood volume. The proposed method was applied to measure the deformability of blood samples consisting of homogeneous RBCs fixed with four different concentrations of glutaraldehyde solution (0%-0.23%). The proposed method was also employed to evaluate the deformability of blood samples partially mixed with normal RBCs and hardened RBCs. Thereafter, the deformability of RBCs infected by human malaria parasite Plasmodium falciparum was measured. As a result, the three parameters significantly varied, depending on the degree of deformability. In addition, the deformability measurement of blood samples was successfully completed in a short time (∼10 min). Therefore, the proposed method has significant potential in deformability measurement of blood samples containing hematological diseases with high throughput and precise detection of subpopulations in RBCs.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, Gwangju, Republic of Korea
| | | | | |
Collapse
|
13
|
Yang L, Okamura Y, Kimura H. Surface modification on polydimethylsiloxane-based microchannels with fragmented poly(l-lactic acid) nanosheets. BIOMICROFLUIDICS 2015; 9:064108. [PMID: 26634016 PMCID: PMC4654732 DOI: 10.1063/1.4936350] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2015] [Accepted: 11/11/2015] [Indexed: 05/08/2023]
Abstract
Surface modification is a critical issue in various applications of polydimethylsiloxane (PDMS)-based microfluidic devices. Here, we describe a novel method through which PDMS-based microchannels were successfully modified with fragmented poly(l-lactic acid) (PLLA) nanosheets through a simple patchwork technique that exploited the high level of adhesiveness of PLLA nanosheets. Compared with other surface modification methods, our method required neither complicated chemical modifications nor the use of organic solvents that tend to cause PDMS swelling. The experimental results indicated that the modified PDMS exhibited excellent capacity for preventing the adhesion and activation of platelets. This simple yet efficient method can be used to fabricate the special PDMS microfluidic devices for biological, medical, and even hematological purposes.
Collapse
Affiliation(s)
- Lu Yang
- Micro/Nano Technology Center, Tokai University , 4-1-1 Kitakaname, Hiratsuka, Kanagawa 259-1292, Japan
| | | | | |
Collapse
|
14
|
Yu ZTF, Guan H, Cheung MK, McHugh WM, Cornell TT, Shanley TP, Kurabayashi K, Fu J. Rapid, automated, parallel quantitative immunoassays using highly integrated microfluidics and AlphaLISA. Sci Rep 2015; 5:11339. [PMID: 26074253 PMCID: PMC4466892 DOI: 10.1038/srep11339] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2015] [Accepted: 05/15/2015] [Indexed: 12/22/2022] Open
Abstract
Immunoassays represent one of the most popular analytical methods for detection and quantification of biomolecules. However, conventional immunoassays such as ELISA and flow cytometry, even though providing high sensitivity and specificity and multiplexing capability, can be labor-intensive and prone to human error, making them unsuitable for standardized clinical diagnoses. Using a commercialized no-wash, homogeneous immunoassay technology ('AlphaLISA') in conjunction with integrated microfluidics, herein we developed a microfluidic immunoassay chip capable of rapid, automated, parallel immunoassays of microliter quantities of samples. Operation of the microfluidic immunoassay chip entailed rapid mixing and conjugation of AlphaLISA components with target analytes before quantitative imaging for analyte detections in up to eight samples simultaneously. Aspects such as fluid handling and operation, surface passivation, imaging uniformity, and detection sensitivity of the microfluidic immunoassay chip using AlphaLISA were investigated. The microfluidic immunoassay chip could detect one target analyte simultaneously for up to eight samples in 45 min with a limit of detection down to 10 pg mL(-1). The microfluidic immunoassay chip was further utilized for functional immunophenotyping to examine cytokine secretion from human immune cells stimulated ex vivo. Together, the microfluidic immunoassay chip provides a promising high-throughput, high-content platform for rapid, automated, parallel quantitative immunosensing applications.
Collapse
Affiliation(s)
- Zeta Tak For Yu
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Huijiao Guan
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Mei Ki Cheung
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Walker M McHugh
- Department of Pediatrics and Communicable Diseases, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Timothy T Cornell
- Department of Pediatrics and Communicable Diseases, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Thomas P Shanley
- Department of Pediatrics and Communicable Diseases, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Katsuo Kurabayashi
- 1] Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA [2] Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Jianping Fu
- 1] Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA [2] Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| |
Collapse
|
15
|
Sha C, Fan Y, Cheng J, Cheng H. Quantitative determination of dopamine in single rat pheochromocytoma cells by microchip electrophoresis with only one high-voltage power supply. J Sep Sci 2015; 38:2357-62. [DOI: 10.1002/jssc.201500009] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2015] [Revised: 04/04/2015] [Accepted: 04/09/2015] [Indexed: 01/18/2023]
Affiliation(s)
- Cuicui Sha
- Department of Pharmacy; South-Central University for Nationalities; Wuhan China
| | - Yuejuan Fan
- Department of Pharmacy; South-Central University for Nationalities; Wuhan China
| | - Jieke Cheng
- Department of Chemistry and Molecular Sciences; Wuhan University; Wuhan China
| | - Han Cheng
- Department of Pharmacy; South-Central University for Nationalities; Wuhan China
| |
Collapse
|