1
|
Grimm DR, Halagur AS, Ayoub N. Complications Associated with AMBU™ Scope Use: An FDA MAUDE Analysis. Otolaryngol Head Neck Surg 2024. [PMID: 38988303 DOI: 10.1002/ohn.898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 06/21/2024] [Accepted: 06/29/2024] [Indexed: 07/12/2024]
Abstract
Ambu® aScope™ is a disposable flexible videoscope used for a wide range of medical procedures. However, adverse events associated with this device can occur. The Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database was explored for patient-related adverse events associated with Ambu® aScope™ use between January 1, 2000 and December 15, 2023. Search terms included "Ambu" and "Ascope." Thirty unique adverse events were identified. Twenty-one of the events were associated with patient injury, and 9 with device malfunction. Eight patient-reported problems were documented as foreign bodies, 3 events as airway obstruction, desaturation, or hypoxic events, and 1 event as anxiety/cardiac arrest. The remaining 18 reported insufficient information other than associated with patient injury. We found that Ambu® aScope™ flexible nasolaryngoscopes and bronchoscopes are a common and effective tool for airway evaluations that may infrequently serve as a rare form of foreign body with potentially life-threatening consequences.
Collapse
Affiliation(s)
- David R Grimm
- Department of Otolaryngology-Head and Neck Surgery, Stanford University School of Medicine, Palo Alto, California, USA
| | - Akash S Halagur
- Department of Otolaryngology-Head and Neck Surgery, Stanford University School of Medicine, Palo Alto, California, USA
| | - Noel Ayoub
- Department of Otolaryngology-Head and Neck Surgery, Division of Rhinology and Skull Base Surgery, Mass Eye and Ear, Boston, Massachusetts, USA
| |
Collapse
|
2
|
Cheng SH, Lin YT, Lu HT, Tsuei YC, Chu W, Chu WC. The Evolution of Spinal Endoscopy: Design and Image Analysis of a Single-Use Digital Endoscope Versus Traditional Optic Endoscope. Bioengineering (Basel) 2024; 11:99. [PMID: 38275579 PMCID: PMC10813680 DOI: 10.3390/bioengineering11010099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 01/11/2024] [Accepted: 01/17/2024] [Indexed: 01/27/2024] Open
Abstract
Spinal endoscopy has evolved significantly since its inception, offering minimally invasive solutions for various spinal pathologies. This study introduces a promising innovation in spinal endoscopy-a single-use digital endoscope designed to overcome the drawbacks of traditional optic endoscopes. Traditional endoscopes, despite their utility, present challenges such as fragility, complex disinfection processes, weight issues, and susceptibility to mechanical malfunctions. The digital endoscope, with its disposable nature, lighter weight, and improved image quality, aims to enhance surgical procedures and patient safety. The digital endoscope system comprises a 30-degree 1000 × 1000 pixel resolution camera sensor with a 4.3 mm working channel, and LED light sources replacing optical fibers. The all-in-one touch screen tablet serves as the host computer, providing portability and simplified operation. Image comparisons between the digital and optic endoscopes revealed advantages in the form of increased field of view, lesser distortion, greater close-range resolution, and enhanced luminance. The single-use digital endoscope demonstrates great potential for revolutionizing spine endoscopic surgeries, offering convenience, safety, and superior imaging capabilities compared to traditional optic endoscopes.
Collapse
Affiliation(s)
- Shih-Hao Cheng
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
- Department of Orthopedics, Cheng Hsin General Hospital, Taipei 11221, Taiwan
| | - Yen-Tsung Lin
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
| | - Hsin-Tzu Lu
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
| | - Yu-Chuan Tsuei
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
- Department of Orthopedics, Cheng Hsin General Hospital, Taipei 11221, Taiwan
| | - William Chu
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
- Department of Orthopedics, Cheng Hsin General Hospital, Taipei 11221, Taiwan
- School of Nursing, National Taipei University of Nursing and Health Sciences, Taipei 11221, Taiwan
| | - Woei-Chyn Chu
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
| |
Collapse
|
3
|
Rutala WA, Weber DJ. Reprocessing semicritical items: An overview and an update on the shift from HLD to sterilization for endoscopes. Am J Infect Control 2023; 51:A96-A106. [PMID: 37890958 DOI: 10.1016/j.ajic.2023.01.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 01/04/2023] [Indexed: 10/29/2023]
Abstract
BACKGROUND Semicritical medical devices are defined as items that come into contact with mucous membranes or nonintact skin (e.g., gastrointestinal endoscopes, endocavitary probes). Such medical devices require minimally high-level disinfection. METHODS Analyze the methods used to reprocess semicritical medical devices and identify methods and new technologies to reduce the risk of infection. RESULTS The reprocessing methods for semicritical medical devices is described as well as a shift from high-level disinfection to sterilization for lumened endoscopes. CONCLUSIONS Strict adherence to current guidelines and transition to sterilization for endoscopes is required as more outbreaks have been linked to inadequately disinfected endoscopes and other semicritical items than any other reusable medical devices.
Collapse
Affiliation(s)
- William A Rutala
- Statewide Program for Infection Control and Epidemiology, University of North Carolina Hospitals, Chapel Hill, NC; Division of Infectious Diseases, UNC School of Medicine, Chapel Hill, NC.
| | - David J Weber
- Statewide Program for Infection Control and Epidemiology, University of North Carolina Hospitals, Chapel Hill, NC; Division of Infectious Diseases, UNC School of Medicine, Chapel Hill, NC; Department of Infection Prevention, Hospital Epidemiology, University of North Carolina Hospitals, Chapel Hill, NC
| |
Collapse
|
4
|
Shahid HM, Bareket R, Tyberg A, Sarkar A, Simon A, Gurram K, Gress FG, Bhenswala P, Chalikonda D, Loren DE, Kowalski TE, Kumar A, Vareedayah AA, Abhyankar PR, Parker K, Gabr MM, Nieto J, De Latour R, Zolotarevsky M, Barber J, Zolotarevsky E, Vazquez-Sequeiros E, Gaidhane M, Andalib I, Kahaleh M. Comparing the Safety and Efficacy of Two Commercially Available Single-Use Duodenoscopes: A Multicenter Study. J Clin Gastroenterol 2023; 57:798-803. [PMID: 35997700 DOI: 10.1097/mcg.0000000000001752] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Accepted: 07/07/2022] [Indexed: 12/10/2022]
Abstract
INTRODUCTION Single-use disposable duodenoscopes (SDD) have been developed to mitigate infectious risks related to reusable duodenoscopes. The aim of this study is to compare the safety and efficacy of the two available SDDs in the United States. METHODS We conducted a comparative study of 2 SDD in consecutive ERCP procedures performed by expert endoscopists from 9 academic centers. Performance ratings, procedure details, and adverse events were collected. RESULTS A total of 201 patients were included: 129 patients underwent ERCP with Exalt (mean age 63, Males- 66 (51%), 72 with aScope Duodeno (mean age 65, males=30 (42%). A majority of endoscopists had performed >2000 ERCPs in both groups (71% Exalt, 93% aScope Duodeno). Technical success was 92% in both groups (n=119 Exalt-group, n=66 aScope-Duodeno-group). The procedural complexity for the ERCP cases performed were: Grade 1: 35 cases (18%), Grade 2: 83 cases (41%), Grade 3: 65 cases (32%), and Grade 4: 18 cases (9%). Thirteen patients (10%) from the Exalt group and 16 patients (22%) from the aScope Duodeno group required conversion to a reusable duodenoscope. On a scale of 1 to 5, Exalt and aScope Duodeno, respectively, were rated: 2.31 versus 2.60 for location and visualization quality, 1.38 versus 1.57 for maneuverability based on papillary orientation, 1.48 versus 1.15 for suction/air control, and 2.31 versus 2.34 for elevator efficiency. None of the adverse events were related to the SDDs. CONCLUSIONS The 2 SDDs were comparable. Further ongoing enhancements to these devices will improve maneuverability and clinical effectiveness.
Collapse
Affiliation(s)
- Haroon M Shahid
- Endoscopy, Robert Wood Johnson Medical School, New Brunswick, NJ
| | - Romy Bareket
- Endoscopy, Robert Wood Johnson Medical School, New Brunswick, NJ
| | - Amy Tyberg
- Endoscopy, Robert Wood Johnson Medical School, New Brunswick, NJ
| | - Avik Sarkar
- Endoscopy, Robert Wood Johnson Medical School, New Brunswick, NJ
| | - Alexa Simon
- Endoscopy, Robert Wood Johnson Medical School, New Brunswick, NJ
| | | | | | | | | | | | | | - Anand Kumar
- Thomas Jefferson University, Philadelphia, PA
| | | | | | | | | | - Jose Nieto
- Borland Groover Clinic, Jacksonville, FL
| | | | | | | | | | | | - Monica Gaidhane
- Endoscopy, Robert Wood Johnson Medical School, New Brunswick, NJ
| | - Iman Andalib
- Elmhurst Mount Sinai, Icahn School of Medicine New York
| | - Michel Kahaleh
- Endoscopy, Robert Wood Johnson Medical School, New Brunswick, NJ
| |
Collapse
|
5
|
Tran VN, Park S, Khan F, Truong VG, Jeong S, Lee DH, Kim YM, Kang HW. Collective bacterial disinfection by opto-chemical treatment on mature biofilm in clinical endoscope. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY. B, BIOLOGY 2022; 226:112367. [PMID: 34847498 DOI: 10.1016/j.jphotobiol.2021.112367] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 11/12/2021] [Accepted: 11/17/2021] [Indexed: 02/07/2023]
Abstract
The present study proposes an innovative opto-chemical treatment using a basket-integrated optical device (BIOD) to disinfect mature bacterial biofilm on endoscope channels. A BIOD was designed to position an optical diffuser on the central axis of an endoscope channel and to distribute laser light concentrically to the bacterial biofilm on the channel surface. To apply thermal damage and oxidative stress to the bacterial biofilm, a low concentration of a crosslinking agent (glutaraldehyde ~0.5%) was combined with 808 nm infrared (IR) and 405 nm blue (BL) laser lights. The applied irradiances of IR and BL were 10 W/cm2 and 1.6 W/cm2 for Teflon channel model and 20 W/cm2 and 3.2 W/cm2 for a clinical model, respectively. Individual irradiation of either IR or BL for 180 s induced the maximum temperatures of 62 ± 2 °C and 53 ± 3 °C on the biofilm, respectively. The simultaneous opto-chemical treatment reduced a significant population of the bacterial biofilms (7.5-log10 for Staphylococcus aureus and 7.1-log10 for Pseudomonas aeruginosa), which were 2.9-fold and 3.9-fold higher than that of the standard treatment with 2% glutaraldehyde (GA) solution, respectively. The proposed opto-chemical disinfection method can help reduce multi-drug resistant bacteria and prevent cross-infection during the clinical usage of a flexible endoscope.
Collapse
Affiliation(s)
- Van Nam Tran
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, South Korea
| | - Suhyun Park
- Department of Electronic and Electrical Engineering, Ewha Womans University, Seoul 03760, South Korea
| | - Fazlurrahman Khan
- Research Center for Marine Integrated Bionics Technology, Pukyong National University, Busan 48513, South Korea
| | - Van Gia Truong
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, South Korea
| | - Seok Jeong
- Division of Gastroenterology, Department of Internal Medicine, Inha University College of Medicine, Incheon 22212, South Korea
| | - Don Haeng Lee
- Division of Gastroenterology, Department of Internal Medicine, Inha University College of Medicine, Incheon 22212, South Korea
| | - Young-Mog Kim
- Research Center for Marine Integrated Bionics Technology, Pukyong National University, Busan 48513, South Korea; Department of Food Science and Technology, Pukyong National University, Busan 48513, South Korea
| | - Hyun Wook Kang
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, South Korea; Research Center for Marine Integrated Bionics Technology, Pukyong National University, Busan 48513, South Korea; Department of Biomedical Engineering, Pukyong National University, Busan 48513, South Korea.
| |
Collapse
|
6
|
Heuvelmans M, Wunderink HF, van der Mei HC, Monkelbaan JF. A narrative review on current duodenoscope reprocessing techniques and novel developments. Antimicrob Resist Infect Control 2021; 10:171. [PMID: 34949217 PMCID: PMC8697464 DOI: 10.1186/s13756-021-01037-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 11/19/2021] [Indexed: 11/10/2022] Open
Abstract
Duodenoscopy-associated infections occur worldwide despite strict adherence to reprocessing standards. The exact scope of the problem remains unknown because a standardized sampling protocol and uniform sampling techniques are lacking. The currently available multi-society protocol for microbial culturing by the Centers for Disease Control and Prevention, the United States Food and Drug Administration (FDA) and the American Society for Microbiology, published in 2018 is too laborious for broad clinical implementation. A more practical sampling protocol would result in increased accessibility and widespread implementation. This will aid to reduce the prevalence of duodenoscope contamination. To reduce the risk of duodenoscopy-associated pathogen transmission the FDA advised four supplemental reprocessing measures. These measures include double high-level disinfection, microbiological culturing and quarantine, ethylene oxide gas sterilization and liquid chemical sterilization. When the supplemental measures were advised in 2015 data evaluating their efficacy were sparse. Over the past five years data regarding the supplemental measures have become available that place the efficacy of the supplemental measures into context. As expected the advised supplemental measures have resulted in increased costs and reprocessing time. Unfortunately, it has also become clear that the efficacy of the supplemental measures falls short and that duodenoscope contamination remains a problem. There is a lot of research into new reprocessing methods and technical applications trying to solve the problem of duodenoscope contamination. Several promising developments such as single-use duodenoscopes, electrolyzed acidic water, and vaporized hydrogen peroxide plasma are already applied in a clinical setting.
Collapse
Affiliation(s)
- Maarten Heuvelmans
- Department of Medical Microbiology, University Medical Center Utrecht, G04.643, PO box 85500, 3508GA, Utrecht, The Netherlands.
| | - Herman F Wunderink
- Department of Medical Microbiology, University Medical Center Utrecht, G04.643, PO box 85500, 3508GA, Utrecht, The Netherlands
| | - Henny C van der Mei
- Department of Biomedical Engineering, University of Groningen and University Medical Center Groningen, Groningen, The Netherlands
| | - Jan F Monkelbaan
- Department of Gastroenterology and Hepatology, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
7
|
Oikonomou KG, Papamichalis P, Zafeiridis T, Xanthoudaki M, Papapostolou E, Valsamaki A, Bouliaris K, Papamichalis M, Karvouniaris M, Vlachostergios PJ, Skoura AL, Komnos A. Gastroenterology and liver disease during COVID-19 and in anticipation of post-COVID-19 era: Current practice and future directions. World J Clin Cases 2021; 9:4918-4938. [PMID: 34307544 PMCID: PMC8283616 DOI: 10.12998/wjcc.v9.i19.4918] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 04/10/2021] [Accepted: 05/25/2021] [Indexed: 02/06/2023] Open
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has emerged as a major threat to global public health. The virus causes the clinical syndrome known as coronavirus disease 2019 (COVID-19), in which multiple organs can get affected. Apart from manifestations of the respiratory system, which predominate, its clinical presentation is frequently accompanied by symptoms of the gastro-intestinal (GI) tract and liver abnormalities. The correlation of symptoms and abnormalities with disease severity is discussed, leading to ambiguous results from international literature. Moreover, the disease infects patients with co-existing liver and GI disorders affecting both their health status and the availability of healthcare services provided to them. The risk of transmission of the disease during aerosol-generating procedures has changed the diagnostic approach and follow-up algorithms for liver and GI diseases. For the safety of both doctors and patients, telemedicine and distant evaluation have become everyday practice, whereas several routines and emergency visits at outpatient and emergency departments have been postponed or delayed. Vaccination against SARS-CoV-2 is underway, providing hope to humanity and the expectation that the post-COVID-19 era is near. This review aims to update knowledge about the manifestations of COVID-19 related to liver and GI diseases and the effect of the pandemic on the diagnostic and therapeutic procedures for these diseases with a special focus on how current practices have changed and what changes will possibly remain in the future.
Collapse
Affiliation(s)
- Katerina G Oikonomou
- Intensive Care Unit, General Hospital of Larissa, Larissa 41221, Thessaly, Greece
| | | | | | - Maria Xanthoudaki
- Intensive Care Unit, General Hospital of Larissa, Larissa 41221, Thessaly, Greece
| | | | - Asimina Valsamaki
- Intensive Care Unit, General Hospital of Larissa, Larissa 41221, Thessaly, Greece
| | | | - Michail Papamichalis
- Department of Cardiology, University Hospital of Larissa, Larissa 41110, Thessaly, Greece
| | - Marios Karvouniaris
- Intensive Care Unit, University Hospital of Larissa, Larissa 41110, Thessaly, Greece
| | - Panagiotis J Vlachostergios
- Division of Hematology and Medical Oncology, Department of Medicine, Weill Cornell Medicine, New York, NY 10065, United States
| | - Apostolia-Lemonia Skoura
- Intensive Care Unit, University Hospital of Larissa, Larissa 41110, Thessaly, Greece
- Transfusion Medicine Department, University Hospital of Larissa, Larissa 41110, Thessaly, Greece
| | - Apostolos Komnos
- Intensive Care Unit, General Hospital of Larissa, Larissa 41221, Thessaly, Greece
| |
Collapse
|