1
|
Li Y, Schuller RM, Wu J. An accurate genetic assay to identify human neutrophil antigen 2 deficiency. Transfus Med 2023; 33:68-74. [PMID: 36308061 PMCID: PMC9974537 DOI: 10.1111/tme.12936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 09/08/2022] [Accepted: 10/15/2022] [Indexed: 10/31/2022]
Abstract
OBJECTIVE We aimed to develop accurate and user-friendly genetic assays to identify the inherited neutrophil antigen-2 (HNA-2) deficiency in humans. BACKGROUND HNA-2 is one of the most important neutrophil antigens implicated in a number of human disorders. HNA-2 deficiency or HNA-2 null is a common phenotype observed in 3%-5% Americans. HNA-2 null individuals are at risk to produce isoantibodies (or alloantibodies) that play important roles in transfusion-related acute lung injury, immune neutropenia, and bone marrow graft failure. We previously demonstrated that the CD177 coding SNP 787A > T (c.787A > T) is the most important genetic determinant for HNA-2 deficiency. However, reliable genetic assays are not available for routine clinical laboratory application up to now. STUDY DESIGN AND METHODS A novel polymerase chain reaction (PCR) strategy was used to determine genotypes of the CD177 SNP c.787A > T. In the simplified PCR assay, all allele specific primers and internal control primers were included in the same reaction, which ensures reliability of the assay. In addition, a novel high-throughput nested TaqMan assay was developed to determine genotypes of c.787A > T for large population genetic analysis of HNA-2 deficiency. RESULTS CD177 SNP c787A > T genotypes of 396 subjects were 100% concordant among the single PCR reaction method, the nested TaqMan assay, and Sanger Sequencing analysis. Out of 396 subjects, all 18 donors with the CD177 STP homozygous genotype were HNA-2 null. CONCLUSION The novel PCR-based genotyping assay is accurate to identify HNA-2 deficient individuals and is suitable for clinical laboratories. In addition, the innovative high-throughput nested TaqMan assay will be useful for large-scale population screens and genetic studies of HNA-2 deficiency.
Collapse
Affiliation(s)
- Yunfang Li
- Department of Veterinary and Biomedical Sciences, University of Minnesota. St. Paul, MN
| | - Randy M. Schuller
- American Red Cross, North Central Blood Services, National Neutrophil Reference Laboratory, St. Paul, MN
| | - Jianming Wu
- Department of Veterinary and Biomedical Sciences, University of Minnesota. St. Paul, MN
| |
Collapse
|
2
|
Wu J, Li Y, Schuller RM, Li L, Litmeyer AS, Bein G, Sachs UJ, Bayat B. The nonconservative CD177 single-nucleotide polymorphism c.1291G>A is a genetic determinant for human neutrophil antigen-2 atypical/low expression and deficiency. Transfusion 2019; 59:1836-1842. [PMID: 30828823 DOI: 10.1111/trf.15222] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2018] [Revised: 01/18/2019] [Accepted: 01/18/2019] [Indexed: 12/19/2022]
Abstract
BACKGROUND Human neutrophil antigen-2 (HNA-2) is exclusively expressed on neutrophils. HNA-2-deficient individuals (HNA-2 null) are susceptible to produce isoantibodies. The nonsense CD177 coding single-nucleotide polymorphism (SNP) c.787A>T has been demonstrated as the primary genetic mechanism for HNA-2 deficiency. We hypothesized that the other genetic variants also contribute to HNA-2 expression variation and deficiency. STUDY DESIGN AND METHODS The deficiency, density, and percentage of HNA-2 antigen on neutrophils from 292 healthy blood donors were determined in flow cytometry. CD177 genotypes were determined by genomic DNA sequence analyses. The full-length CD177 cDNAs were amplified and sequenced. Additionally, the whole CD177 genomic sequence in eight HNA-2-null immunized women and four HNA-2-positive donors were analyzed with next-generation sequencing. The associations of CD177 SNP genotypes with HNA-2 expression variation were statistically analyzed. RESULTS A functional CD177 SNP c.1291G>A was identified in the current study. Atypical (trimodal) HNA-2 expression phenotype was consistently observed in donors carrying the heterozygous c.1291G/A genotype. Phenotype-genotype analyses of SNP c.787A>T and SNP c.1291G>A revealed that all homozygous 787T-1291G (TG/TG) genotype donors were HNA-2 null in healthy blood donors. On the other hand, five of eight HNA-2-immunized females were homozygous for the 787T-1291G (TG/TG) genotype while the other three HNA-2-immunized females had the 787T-1291G/787A-1291A (TG/AA) genotype and the lowest HNA-2 expression was observed in healthy subjects with the 787T-1291G/787A-1291A (TG/AA) and 787A-1291A/787A-1291A (AA/AA) genotype. CONCLUSION The CD177 SNP c.1291G>A is a genetic determinant for the atypical and low HNA-2 expression, which also contributes to HNA-2 deficiency phenotype.
Collapse
Affiliation(s)
- Jianming Wu
- Department of Veterinary and Biomedical Sciences, University of Minnesota, St Paul, Minnesota
| | - Yunfang Li
- Department of Veterinary and Biomedical Sciences, University of Minnesota, St Paul, Minnesota
| | - Randy M Schuller
- North Central Blood Services, National Neutrophil Reference Laboratory, American Red Cross, St Paul, Minnesota
| | - Ling Li
- Department of Clinical and Experimental Pharmacology, University of Minnesota Twin Cities, Minneapolis, Minnesota
| | - Anne-Sophie Litmeyer
- Institute for Clinical Immunology and Transfusion Medicine, Justus Liebig University, Giessen, Germany
| | - Gregor Bein
- Institute for Clinical Immunology and Transfusion Medicine, Justus Liebig University, Giessen, Germany
| | - Ulrich J Sachs
- Institute for Clinical Immunology and Transfusion Medicine, Justus Liebig University, Giessen, Germany
| | - Behnaz Bayat
- Institute for Clinical Immunology and Transfusion Medicine, Justus Liebig University, Giessen, Germany
| |
Collapse
|
3
|
Time from venipuncture to cell isolation: Impact on granulocyte-reactive antibody testing. Clin Biochem 2018; 63:72-78. [PMID: 30447182 DOI: 10.1016/j.clinbiochem.2018.10.017] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2018] [Revised: 10/29/2018] [Accepted: 10/30/2018] [Indexed: 11/23/2022]
Abstract
BACKGROUND AND OBJECTIVES Classical neutrophil-reactive antibody testing depends on the quick isolation of neutrophils from freshly taken whole blood. To allow a better logistic preparation before testing, the influence of time interval between venipuncture and cell isolation has been evaluated in this study. MATERIALS AND METHODS Neutrophils and whole leukocytes were isolated from EDTA whole blood immediately (T0) as well as 4, 8 and 24 h after blood donation (T4, T8 and T24). These cells were tested against reference sera containing antibodies against HNA-1b, -2, -3a and HLA class I using granulocyte aggregation test (GAT), microscopic granulocyte immunofluorescence test (GIFT) and flow-cytometric white blood cell immunofluorescence test (Flow-GIFT/WIFT). RESULTS GAT was the most error-prone test displaying overall weaker aggregation strengths already at T4 (overall accuracy OA = 0.72, κ = 0.58). GIFT results showed good agreement at T4 (OA = 0.86, κ = 0.79) and remained stable until T8, while test results were slightly impaired at T24 (OA = 0.71, κ = 0.55). Flow-GIFT/WIFT was identified as the most robust screening method, remaining stable even at T24. Calculated ratios (sample/negative control) decreased non-significantly and remained highly above the cut-off in all samples. CONCLUSION Acceptable time limits for cell isolation are different for each screening method investigated. For GAT, cell isolation should be performed within 4 h, while GIFT tolerates a neutrophil isolation delay of 8 h. Flow-GIFT/WIFT isolation can be performed even after 24 h without impairment of the results. Using the latter test as a stand-alone pre-screening test, whole blood can be used from donors who are not directly accessible.
Collapse
|
4
|
Peters AL, Van Stein D, Vlaar APJ. Antibody-mediated transfusion-related acute lung injury; from discovery to prevention. Br J Haematol 2015; 170:597-614. [PMID: 25921271 DOI: 10.1111/bjh.13459] [Citation(s) in RCA: 72] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Transfusion-related acute lung injury (TRALI), a syndrome of respiratory distress caused by blood transfusion, is the leading cause of transfusion-related mortality. The majority of TRALI cases have been related to passive infusion of human leucocyte antigen (HLA) and human neutrophil antigen (HNA) antibodies in donor blood. In vitro, ex vivo and in vivo animal models have provided insight in TRALI pathogenesis. The various classes of antibodies implicated in TRALI appear to have different pathophysiological mechanisms for the induction of TRALI involving endothelial cells, neutrophils, monocytes and, as very recently has been discovered, lymphocytes. The HLA and HNA-antibodies are found mainly in blood from multiparous women as they have become sensitized during pregnancy. The incidence of TRALI has decreased rapidly following the introduction of a male-only strategy for plasma donation. This review focuses on pre-clinical and clinical studies investigating the pathophysiology of antibody-mediated TRALI.
Collapse
Affiliation(s)
- Anna L Peters
- Laboratory of Experimental Intensive Care and Anaesthesia/Intensive Care, Academic Medical Centre, Amsterdam, The Netherlands
| | - Danielle Van Stein
- Department of Internal Medicine, Leiden University Medical Centre, Leiden, The Netherlands
| | - Alexander P J Vlaar
- Laboratory of Experimental Intensive Care and Anaesthesia/Intensive Care, Academic Medical Centre, Amsterdam, The Netherlands
| |
Collapse
|
5
|
Heinzl MW, Schönbacher M, Dauber EM, Panzer S, Mayr WR, Körmöczi GF. Detection of granulocyte-reactive antibodies: a comparison of different methods. Vox Sang 2014; 108:287-93. [PMID: 25556963 DOI: 10.1111/vox.12227] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2014] [Revised: 10/15/2014] [Accepted: 11/03/2014] [Indexed: 11/29/2022]
Abstract
BACKGROUND AND OBJECTIVES Granulocyte-reactive antibodies can cause autoimmune and neonatal immune neutropenias as well as transfusion-related acute lung injury. The classical antibody-detection methods granulocyte aggregation test (GAT), granulocyte immunofluorescence test (GIFT) and monoclonal antibody-specific immobilization of granulocyte antigens (MAIGA) are time-consuming and technically challenging. In recent years, flow cytometric white blood cell immunofluorescence test (Flow-WIFT) and the microbeads assay LabScreen® Multi have emerged and are still subject of evaluation. These serological tests were compared on a screening and specification level. MATERIALS AND METHODS For screening, the combination of GAT/GIFT was compared to Flow-WIFT testing 333 samples. Positive samples were further analysed with MAIGA and LabScreen® Multi. RESULTS Granulocyte aggregation test/GIFT detected 77 positive samples, Flow-WIFT found 108 granulocyte-reactive samples. Six Samples were only positive in GAT/GIFT, and 37 samples were only positive in Flow-WIFT (κ = 0.682). Antibody specification with MAIGA and the microbeads assay confirmed granulocyte-reactivity in 83 cases with 70 matching results (κ = 0.742). However, out of six detected human neutrophil antigen (HNA) reactivities only two specificities matched in both assays. CONCLUSION Flow-WIFT may be a valuable addition to GIFT for granulocyte-reactive antibody screening. MAIGA remains the most reliable laboratory method for antibody specification.
Collapse
Affiliation(s)
- M W Heinzl
- Department of Blood Group Serology and Transfusion Medicine, Medical University of Vienna, Vienna, Austria
| | | | | | | | | | | |
Collapse
|
6
|
Gandhi MJ, Carrick DM, Jenkins S, De Goey S, Ploeger NA, Wilson GA, Lee JH, Winters JL, Stubbs JR, Toy P, Norris PJ. Lot-to-lot variability in HLA antibody screening using a multiplexed bead-based assay. Transfusion 2013; 53:1940-7. [PMID: 23305156 DOI: 10.1111/trf.12064] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2012] [Revised: 10/23/2012] [Accepted: 10/23/2012] [Indexed: 01/24/2023]
Abstract
BACKGROUND Identifying antibodies to HLA (anti-HLA) by solid-phase assays is used to screen blood donors to mitigate transfusion-related acute lung injury risk. Various cutoffs for detection assays have been proposed in the literature; however, these do not take into consideration lot-to-lot variability of commercially available assays. STUDY DESIGN AND METHODS Samples from 93 nontransfused males were tested using five different lots of a multiplex bead-based anti-HLA detection kit. A subset of 17 samples was tested on 5 days using a single lot. An additional 96 samples from donations with varied anti-HLA levels were tested using kits from two different lots. Results were reported as a normalized background (NBG) ratio. RESULTS For the 93 nontransfused donors, NBG values generated using the reference lot were significantly higher than those obtained with three of the four comparator lots. However, for the 96 samples with low-, moderate-, and higher-level anti-HLA, Class I (CL-I) values were 1.4 times lower and Class II (CL-II) values were 1.2 times lower using the reference versus comparator lot. For CL-I antibodies the between-lot standard deviation (SD) was 1.36 (95% confidence interval [CI], 1.19-1.60), while the between-day SD was 1.27 (95% CI, 1.08-1.52). Similarly, for CL-II antibodies the between-lot SD was 0.81 (95% CI, 0.70-0.95), while the between-day SD was 0.50 (95% CI, 0.43-0.60). CONCLUSIONS There is interlot variability in the tested HLA detection assay as well as significant bias between lots. It may be reasonable to develop a new cutoff when a new lot is obtained.
Collapse
Affiliation(s)
- Manish J Gandhi
- Department of Laboratory Medicine and Pathology, Department of Biomedical Statistics & Informatics, Department of Anesthesiology, Division of Transfusion Medicine, Mayo Clinic, Rochester, Minnesota; Westat, Inc., Rockville, Maryland; One Lambda, Inc., Canoga Park, California; Deparment of Laboratory Medicine, University of California at San Francisco, Blood Systems Research Institute, San Francisco, California
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Implementation and outcomes of a transfusion-related acute lung injury surveillance programme and study of HLA/HNA alloimmunisation in blood donors. BLOOD TRANSFUSION = TRASFUSIONE DEL SANGUE 2012; 10:351-9. [PMID: 22395353 DOI: 10.2450/2012.0089-11] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Received: 08/04/2011] [Accepted: 11/07/2011] [Indexed: 11/21/2022]
Abstract
BACKGROUND Transfusion-related acute lung injury (TRALI) is the leading cause of transfusion-associated mortality. Antibodies against human leucocyte antigens (HLA) and human neutrophil antigens (HNA) are often detected in the implicated donors. We investigated the incidence and aetiology of TRALI in Lombardy. Moreover, we determined the rate of HLA and HNA alloimmunisation and the HNA genotype in a cohort of local blood donors. MATERIALS AND METHODS During a 2-year observational study in eight blood transfusion services, suspected TRALI cases were collected and characterised by means of HLA and HNA antibody screening of implicated donors, donor/recipient cross-matching and HLA/HNA molecular typing. In addition, 406 Italian donors were evaluated for alloimmunisation and in 102 of them HNA gene frequencies were determined. RESULTS Eleven cases were referred to the central laboratory, of whom three were diagnosed as having TRALI, seven as having possible TRALI and one as having transfusion-associated circulatory overload. Seven TRALI cases were immune-mediated whereas in three we did not find either alloantibodies in implicated donors or a positive reaction in the cross-match. The most frequently implicated blood component was red blood cells (in 5 males and in 1 female), whereas four cases of TRALI were associated with transfusion of fresh-frozen plasma (in 3 females and in 1 male). The frequency of reported TRALI/possible TRALI cases was 1:82,000 for red blood cells and 1:22,500 for fresh-frozen plasma. No cases were observed for platelets. Overall, the frequency of HLA or HNA alloimmunisation in blood donors was 29% for females and 7% for males. The latter could be related, at least in part, to natural antibodies. HNA gene frequencies showed that HNA-1b is more frequent than HNA-1a in our sample of donors. DISCUSSION The recently adopted national policy to prevent TRALI, i.e. using only plasma donated by males, would have had a positive impact in our setting.
Collapse
|
8
|
Bayat B, Tjahjono Y, Werth S, Berghöfer H, Reil A, Kroll H, Sachs UJ, Santoso S. Implication of transfected cell lines for the detection of alloantibodies against human neutrophil antigen-3. Transfusion 2011; 52:613-21. [DOI: 10.1111/j.1537-2995.2011.03303.x] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
9
|
Fromont P, Prié N, Simon P, Cesbron-Gautier A, Quelvennec E, Bignon JD, Muller JY, Audrain M. Granulocyte antibody screening: evaluation of a bead-based assay in comparison with classical methods. Transfusion 2011; 50:2643-8. [PMID: 20576014 DOI: 10.1111/j.1537-2995.2010.02762.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Granulocyte antibodies have been implicated in allo- and autoimmune neutropenia and in transfusion reactions. STUDY DESIGN AND METHODS Fifty-one sera from suspected alloimmune neutropenia or transfusion-related acute lung injury (TRALI) and 40 sera from suspected autoimmune neutropenia were tested for granulocyte antibodies using LABScreen MULTI (One Lambda, Inc.), compared with classical tests (flow cytometry [FC] and granulocyte agglutination [GAT] followed by monoclonal antibody-specific immobilization of granulocyte antigens [MAIGA]). RESULTS In alloimmune situations, 48 sera were concordant (94%), two sera positive for HNA with LABScreen MULTI were negative by FC/GAT and/or MAIGA, and one serum sample negative for HNA with LABScreen MULTI was positive by classical tests. In autoimmune neutropenia, 30 sera were concordant (75%), four sera positive for HNA with LABScreen MULTI were negative by FC/GAT and/or MAIGA, and six sera negative for HNA with LABScreen MULTI were positive by FC/GAT and/or MAIGA. For detection of autoantibodies, the LABScreen MULTI was less concordant. However, with the exception of one case, the discrepancies were observed in sera that did not show a clear specificity. CONCLUSIONS LABScreen MULTI correlated well with our classical methods for HNA-1 and HNA-2a antibody screening. It can be used for screening blood donors or patients suspected of TRALI, but GAT is still needed for HNA-3a antibody screening.
Collapse
|
10
|
Vassallo RR, Hsu S, Einarson M, Barone J, Brodsky J, Moroff G. A comparison of two robotic platforms to screen plateletpheresis donors for HLA antibodies as part of a transfusion-related acute lung injury mitigation strategy. Transfusion 2010; 50:1766-77. [DOI: 10.1111/j.1537-2995.2010.02626.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
11
|
The neutrophil alloantigen HNA-3a (5b) is located on choline transporter-like protein 2 and appears to be encoded by an R>Q154 amino acid substitution. Blood 2009; 115:2073-6. [PMID: 20040764 DOI: 10.1182/blood-2009-11-248336] [Citation(s) in RCA: 71] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
The molecular basis of the HNA-3a/b (5b/a) leukocyte antigen system has not yet been defined despite evidence that HNA-3a-specific antibodies are particularly prone to cause severe, often fatal, transfusion-related lung injury. We used genome-wide single nucleotide polymorphism scanning and sequencing of DNA from persons of different HNA-3a/b phenotypes to identify a single single nucleotide polymorphism in exon 7 of the CLT2 gene (SLC44A2) that predicts an amino acid substitution in the first extracellular loop of choline transporter-like protein 2, a member of the choline transporter-like protein family of membrane glycoproteins, and correlates perfectly with HNA-3a/b phenotypes (R154 encodes HNA-3a; Q154 encodes HNA-3b). Mass spectrometric analysis of proteins immunoprecipitated from leukocytes by anti-HNA-3a provided direct evidence that anti-HNA-3a recognizes choline transporter-like protein 2. These findings will enable large-scale genotyping for HNA-3a/b to identify blood donors at risk to have HNA-3a-specific antibodies and should facilitate development of practical methods to detect such antibodies and prevent transfusion-related lung injury.
Collapse
|
12
|
Fung YL, Silliman CC. The role of neutrophils in the pathogenesis of transfusion-related acute lung injury. Transfus Med Rev 2009; 23:266-83. [PMID: 19765516 DOI: 10.1016/j.tmrv.2009.06.001] [Citation(s) in RCA: 67] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Transfusion-related acute lung injury (TRALI) is the major cause of transfusion related morbidity and mortality, world wide. Efforts to reduce or eliminate this serious complication of blood transfusion are hampered by an incomplete understanding of its pathogenesis. Currently, TRALI is thought to be mediated by donor alloantibodies directed against host leukocytes or the result of 2 distinct clinical events. For both proposed mechanisms, the neutrophil is the key effector cell. This article reviews TRALI pathophysiology, explores the role of the neutrophil, details practical information for appropriate diagnosis and promotes further studies into the pathogenesis of TRALI.
Collapse
Affiliation(s)
- Yoke Lin Fung
- Australian Red Cross Blood Service, Brisbane, Queensland, Australia.
| | | |
Collapse
|
13
|
Imoto S, Kawamura K, Tokumine Y, Araki N, Akita S, Nishimura C, Inaba H, Saigo K, Mabuchi O, Okazaki H. Acute non-hemolytic transfusion reactions and HLA class I antibody: advantages of solid phase assay compared with conventional complement-dependent assay. Transfus Med 2009; 20:95-103. [PMID: 19883399 PMCID: PMC2860765 DOI: 10.1111/j.1365-3148.2009.00972.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
To evaluate the specific reactivity of HLA Class I antibodies (HLA-I Abs) in acute non-hemolytic transfusion reactions (ANHTRs) using solid phase assays (SPAs) and conventional complement-dependent lymphocyte cytotoxicity test (LCT). ANHTRs are major issues in transfusion medicine. Anti-leukocyte antibodies have been implicated as one of the causative agents of transfusion-related acute lung injury (TRALI) and febrile reaction. Antibodies to HLA Class I and/or Class II (HLA Abs) have been intensively studied using SPAs for TRALI, but not for febrile reaction. About 107 patients and 186 donors associated with ANHTRs were screened for HLA Abs by SPAs such as enzyme-linked immunosorbent assay (ELISA) and the Luminex method. When HLA-I Ab was detected, its specific reactivity was evaluated by comparing its specificity identified by the Luminex method using recombinant HLA molecules and cognate HLA antigens (Ags), as well as LCT with or without anti-human globulin (AHG). The incidences of HLA Abs were as high as 32·7% of patients' serum samples and 16% of donors' serum samples. The incidence of HLA-I Abs did not differ significantly between cases of febrile and allergic reactions. However, HLA-I Abs associated with febrile reaction showed a significantly higher rate of possessing specific reactivity to cognate HLA Ags than those associated with allergic reactions. In addition, the Luminex method enabled the detection of HLA-I Abs much earlier than AHG-LCT in serum samples from a patient with febrile reaction and platelet transfusion refractoriness (PTR). SPAs seem more useful than AHG-LCT for evaluating reactivity of antibodies in ANHTR cases.
Collapse
Affiliation(s)
- S Imoto
- Japanese Red Cross Hyogo Blood Center, Kobe, Japan.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Triulzi DJ, Kleinman S, Kakaiya RM, Busch MP, Norris PJ, Steele WR, Glynn SA, Hillyer CD, Carey P, Gottschall JL, Murphy EL, Rios JA, Ness PM, Wright DJ, Carrick D, Schreiber GB. The effect of previous pregnancy and transfusion on HLA alloimmunization in blood donors: implications for a transfusion-related acute lung injury risk reduction strategy. Transfusion 2009; 49:1825-35. [PMID: 19453983 PMCID: PMC2841001 DOI: 10.1111/j.1537-2995.2009.02206.x] [Citation(s) in RCA: 235] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Antibodies to human leukocyte antigens (HLA) in donated blood have been implicated as a cause of transfusion-related acute lung injury (TRALI). A potential measure to reduce the risk of TRALI includes screening plateletpheresis donors for HLA antibodies. The prevalence of HLA antibodies and their relationship to previous transfusion or pregnancy in blood donors was determined. STUDY DESIGN AND METHODS A total of 8171 volunteer blood donors were prospectively recruited by six US blood centers from December 2006 to May 2007. Donors provided a detailed history of pregnancy and transfusion and a sample for HLA Class I and II antibody testing by multiantigen bead flow analysis. RESULTS A total of 8171 donors were enrolled; 7920 (96.9%) had valid HLA antibody test results and 7841 (99%) of those had complete pregnancy and transfusion information. The prevalence of any HLA antibody was similar in nontransfused (n = 1138) and transfused (n = 895) men, 1.0% versus 1.7% (p = 0.16). HLA antibodies were detected in 17.3% of all female donors (n = 5834) and in 24.4% of those with a history of previous pregnancy (n = 3992). The prevalence of HLA antibodies increased in women with greater numbers of pregnancy: 1.7% (zero), 11.2% (one), 22.5% (two), 27.5% (three), and 32.2% (four or more pregnancies; p < 0.0001). CONCLUSION HLA Class I and Class II antibodies are detectable at low prevalence in male donors regardless of transfusion and in female donors without known immunizing events. The prevalence of HLA antibodies increases significantly with more pregnancies. These data will allow blood centers to estimate the impact of HLA antibody testing as a potential TRALI risk reduction measure.
Collapse
Affiliation(s)
- Darrell J Triulzi
- From the Institute for Transfusion Medicine, Pittsburgh, Pennsylvania, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Bayat B, Werth S, Sachs UJH, Santoso S. A novel enzyme-linked immunosorbent assay method for the detection of human neutrophil antigen-2a antibodies. Transfusion 2009; 49:1819-24. [PMID: 19497055 DOI: 10.1111/j.1537-2995.2009.02229.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND Antibodies to human neutrophil antigen (HNA)-2a are responsible for a number of immune-mediated neutropenia disorders. Although several methods exist for the identification of anti-HNA-2a, all these methods have several limitations. In this study, a solid-phase enzyme-linked immunosorbent assay (ELISA) using recombinant HNA-2a antigen (rHNA-2a) allowing rapid detection of HNA-2a antibodies was developed. STUDY DESIGN AND METHODS Soluble rHNA-2 was generated by transfection of insect cells with CD177 vector. Purified rHNA-2a was immobilized on microtiter wells coated with anti-CD177 and was applied to analyze 10 sera containing HNA-2a antibodies. For the evaluation of the ELISA method, results were compared with the standard assay, MAIGA (monoclonal antibody antigen capture assay) for detection of neutrophil antibodies. RESULTS The specificity of HNA-2a antibodies in all sera was confirmed by immunoblotting. Sera were then tested simultaneously in ELISA and MAIGA assays. Nine of 10 sera showed positive reactions in ELISA, whereas only 9 of 10 sera reacted in the standard MAIGA assay. All HNA-2a antibodies were detectable in MAIGA when diluted sera were applied. No reaction was observed with different sera containing neutrophil-reactive antibodies (6 anti-HNA-1a, 4 anti-HNA-1b, and 20 anti-HLA Class I and II) in ELISA. All HNA-2a antibodies were detectable in MAIGA when diluted sera were applied. Notably, sera containing anti-proteinase 3 (PR3) from patients with Wegener's granulomatosis reacted in MAIGA. In contrast, this antibody showed no reaction in ELISA with purified rHNA-2a. CONCLUSIONS These results demonstrated that ELISA with rHNA-2a provides a good method for detecting HNA-2a antibodies in human serum. This assay enables to exclude the presence of autoantibody against PR3 in patient's sera, which cannot be differentiated from anti HNA-2a with current serologic methods.
Collapse
Affiliation(s)
- Behnaz Bayat
- From the Institute for Clinical Immunology and Transfusion Medicine, Justus Liebig University, Giessen, Germany
| | | | | | | |
Collapse
|
16
|
Timmins NE, Palfreyman E, Marturana F, Dietmair S, Luikenga S, Lopez G, Fung YL, Minchinton R, Nielsen LK. Clinical scale ex vivo manufacture of neutrophils from hematopoietic progenitor cells. Biotechnol Bioeng 2009; 104:832-40. [DOI: 10.1002/bit.22433] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
17
|
Eder AF, Benjamin RJ. TRALI risk reduction: Donor and component management strategies. J Clin Apher 2009; 24:122-9. [DOI: 10.1002/jca.20198] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
18
|
Powers A, Stowell CP, Dzik WH, Saidman SL, Lee H, Makar RS. Testing only donors with a prior history of pregnancy or transfusion is a logical and cost-effective transfusion-related acute lung injury prevention strategy. Transfusion 2008; 48:2549-58. [DOI: 10.1111/j.1537-2995.2008.01902.x] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
19
|
Slezak SL, Adams S, Lee-Stroka H, Martin JE, Caruccio L, Stroncek DF. Rapid, single-subject genotyping to predict red blood cell antigen expression. Immunohematology 2008; 24:154-159. [PMID: 19856718 PMCID: PMC2770877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Genotyping is useful to predict the expression of those RBC antigens for which antisera are difficult to obtain and to determine the probable phenotype of highly transfused patients, and it can be used to test stored DNA when a blood sample is not available. This study assessed a sequence-specific primer (SSP)-based genotyping system for blood group alleles suitable for the rapid testing of a small number of samples and assessed the use of stored whole blood. Genomic DNA was isolated from fresh and 1- and 2-week-old stored blood from 20 donors with known ABO and Rh phenotypes and was used for ABO, RHD, and RHCE genotyping using SSPs. The amplicons were analyzed using gel electrophoresis and a novel microfluidic on-chip electrophoresis system. Analysis of DNA from fresh and 1- and 2-week-old blood by SSP and gel electrophoresis yielded the correct ABO, RHD, and RHCE type in all samples, but with DNA from 2-week-old stored blood the amplicons were more difficult to visualize. Analysis of the same samples with the SSP on-chip electrophoresis assay correctly typed all samples except for one RHCE typing discrepancy of a fresh sample and one RHCE typing discrepancy of a 2-week-old sample. Analysis of amplicons by on-chip electrophoresis required one tenth the DNA that gel electrophoresis did and could be completed within 30 minutes compared with 2 hours with gel electrophoresis. Amplicons were also more readily visualized with on-chip electrophoresis. Fresh and 1- and 2-week-old samples could be ABO and RH genotyped with SSP. Analysis using on-chip electrophoresis was easier and more rapid than that using gel electrophoresis, but test reliability was slightly more variable.
Collapse
Affiliation(s)
- S L Slezak
- Department of Transfusion Medicine, National Institutes of Health, Bethesda, MD 20892-1184, USA
| | | | | | | | | | | |
Collapse
|
20
|
Hoftman AC, Hernandez MI, Lee KW, Stiehm ER. Newborn illnesses caused by transplacental antibodies. Adv Pediatr 2008; 55:271-304. [PMID: 19048734 DOI: 10.1016/j.yapd.2008.07.018] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Alice Chang Hoftman
- Division of Immunology/Allergy/Rheumatology, Mattel Children's Hospital at UCLA, UCLA Center for Health Sciences, 10833 Le Conte Avenue, Los Angeles, CA 90095, USA
| | | | | | | |
Collapse
|
21
|
Cruz J, Skipworth E, Blue D, Waxman D, McCarthy L, Smith D. Transfusion-related acute lung injury: A thrombotic thrombocytopenic purpura treatment-associated case report and concise review. J Clin Apher 2008; 23:96-103. [DOI: 10.1002/jca.20158] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|