1
|
Sabrin S, Karmokar DK, Karmakar NC, Hong SH, Habibullah H, Szili EJ. Opportunities of Electronic and Optical Sensors in Autonomous Medical Plasma Technologies. ACS Sens 2023; 8:974-993. [PMID: 36897225 DOI: 10.1021/acssensors.2c02579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/11/2023]
Abstract
Low temperature plasma technology is proving to be at the frontier of emerging medical technologies with real potential to overcome escalating healthcare challenges including antimicrobial and anticancer resistance. However, significant improvements in efficacy, safety, and reproducibility of plasma treatments need to be addressed to realize the full clinical potential of the technology. To improve plasma treatments recent research has focused on integrating automated feedback control systems into medical plasma technologies to maintain optimal performance and safety. However, more advanced diagnostic systems are still needed to provide data into feedback control systems with sufficient levels of sensitivity, accuracy, and reproducibility. These diagnostic systems need to be compatible with the biological target and to also not perturb the plasma treatment. This paper reviews the state-of-the-art electronic and optical sensors that might be suitable to address this unmet technological need, and the steps needed to integrate these sensors into autonomous plasma systems. Realizing this technological gap could facilitate the development of next-generation medical plasma technologies with strong potential to yield superior healthcare outcomes.
Collapse
Affiliation(s)
- Sumyea Sabrin
- Future Industries Institute, University of South Australia, Mawson Lakes Campus, Mawson Lakes, South Australia 5095, Australia
| | - Debabrata K Karmokar
- UniSA STEM, University of South Australia, Mawson Lakes Campus, Mawson Lakes, South Australia 5095, Australia
| | - Nemai C Karmakar
- Electrical and Computer Systems Engineering Department, Monash University, Clayton, Victoria 3800, Australia
| | - Sung-Ha Hong
- Future Industries Institute, University of South Australia, Mawson Lakes Campus, Mawson Lakes, South Australia 5095, Australia
| | - Habibullah Habibullah
- UniSA STEM, University of South Australia, Mawson Lakes Campus, Mawson Lakes, South Australia 5095, Australia
| | - Endre J Szili
- Future Industries Institute, University of South Australia, Mawson Lakes Campus, Mawson Lakes, South Australia 5095, Australia
| |
Collapse
|
2
|
Lakew A, Assefa T, Woldeyohannes M, Megersa N, Chandravanshi BS. Development and validation of liquid chromatography method for simultaneous determination of multiclass seven antibiotic residues in chicken tissues. BMC Chem 2022; 16:5. [PMID: 35189941 PMCID: PMC8862290 DOI: 10.1186/s13065-022-00797-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Accepted: 02/09/2022] [Indexed: 11/10/2022] Open
Abstract
Background Antibiotics are routinely used on poultry for therapy and prevention of diseases and to enhance animal growth. The objective of this study was to develop and validate a sensitive and reliable liquid chromatography with UV detection (LC-UV) method for the simultaneous determination of seven multiclass antibiotic residues (amoxicillin, ampicillin, penicillin, sulfamethoxazole, gentamicin, ciprofloxacin, and erythromycin) in chicken tissues. Methods The liquid chromatography method with UV detection was optimized for complete separation of the seven selected antibiotic compounds with reversed phase and isocratic elution using Hypersil BDS-C18 (3 µm, 100 mm × 4 mm) column. The mobile phase consisted a ratio of 0.05 M Na2HPO4, acetonitrile and methanol (70:10:20), at UV absorption wavelength of 230 nm. The column thermostat was set at 40 °C, the mobile phase flow rate was 1 mL min−1, and the injection volume was 20 μL. Results All the seven standard compounds were eluted within 14 min. The results for: linearity, precision, sensitivity, accuracy, specificity, decision limit (CCα), detection capability (CCβ), suitability and method robustness were validated according to the criteria of Commission Decision 2002/657/EC guidelines. Calibration plot correlation coefficients ranged from 0.9983 to 0.9998 and the percent relative standard deviations for repeated analysis were below 5% indicating acceptable method precision. The limits of detection (LODs) and quantification (LOQs) ranged from 0.098–0.255 μg kg−1 to 0.297–0.574 μg kg−1, respectively. The accuracy study yielded recoveries in the ranges 98.1–107% for the pure compounds and 94.0–102% for the spiked drug free chicken tissue samples. Conclusions The method was found to be appropriate for simultaneous determination of five different classes of seven antibiotic residues in chicken tissues. Furthermore, this is the first instance for the simultaneous determination of seven multiclass, multi-residues analysis using LC-UV from chicken tissue samples. This is a cost-effective and alternative method with simple instrumentation approach for laboratories that lack highly specialized state-of-the-art instrumentation.
Collapse
Affiliation(s)
- Aynalem Lakew
- Ethiopian Public Health Institute, P. O. Box 1242/5654, Addis Ababa, Ethiopia.,Department of Chemistry, College of Natural and Computational Sciences, Addis Ababa University, P. O. Box 1176, Addis Ababa, Ethiopia
| | - Teshome Assefa
- Ethiopian Public Health Institute, P. O. Box 1242/5654, Addis Ababa, Ethiopia
| | | | - Negussie Megersa
- Department of Chemistry, College of Natural and Computational Sciences, Addis Ababa University, P. O. Box 1176, Addis Ababa, Ethiopia
| | - Bhagwan Singh Chandravanshi
- Department of Chemistry, College of Natural and Computational Sciences, Addis Ababa University, P. O. Box 1176, Addis Ababa, Ethiopia.
| |
Collapse
|
3
|
Techniques for the detection and quantification of emerging contaminants. PHYSICAL SCIENCES REVIEWS 2021. [DOI: 10.1515/psr-2021-0055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Abstract
In recent years, the diverse industrial practices and human inputs widely disseminated emerging contaminants (ECs) throughout environmental matrices, which is of great concern. Even at low concentrations, ECs pose major ecological problems and threaten human health and the environment’s biota. Consequently, people’s interest and concerns on the widespread dissemination of environmentally connected ECs of great concern as developed due to their scientific understanding, technical innovation, and socioeconomic awareness. Increased detection of contaminants may occur from climatic, socioeconomic, and demographic changes and the growing sensitivity of analytical techniques. Hence, this article reviews the determination of ECs in ecological specimens, from aquatic setup (river water, marine water, and wastewater), sludge, soil, sediment, and air. Sample collection and the quality measures are summarized. The preparation of samples, including extraction and cleanup and the subsequent instrumental analysis of ECs, are all covered. Traditional and recent extraction and cleanup applications to analyze ECs in samples are reviewed here in this paper. The detection and quantification of ECs using gas chromatography (GC) and liquid chromatography (LC) linked with various detectors, particularly mass spectrometry (MS), is also summarized and explored, as are other possible techniques. This study aims to give readers a more excellent knowledge of how new and improved approaches are being developed and serve as a resource for researchers looking for the best method for detecting ECs in their studies.
Collapse
|
4
|
Label-free electrochemical-immunoassay of cancer biomarkers: Recent progress and challenges in the efficient diagnosis of cancer employing electroanalysis and based on point of care (POC). Microchem J 2021. [DOI: 10.1016/j.microc.2021.106424] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
5
|
Ličen M, Masiero S, Pieraccini S, Drevenšek-Olenik I. Reversible Photoisomerization in Thin Surface Films from Azo-Functionalized Guanosine Derivatives. ACS OMEGA 2021; 6:15421-15430. [PMID: 34151120 PMCID: PMC8210406 DOI: 10.1021/acsomega.1c01879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Accepted: 05/25/2021] [Indexed: 06/13/2023]
Abstract
Two novel azo-functionalized guanosine derivatives were synthesized, and their photoisomerization process was investigated in molecular monolayers at the air-water interface and in the Langmuir-Blodgett (LB) films on solid substrates. Measurements of surface pressure vs area isotherms, surface potential measurements, UV-visible (vis) absorption spectroscopy, Brewster angle microscopy (BAM), and atomic force microscopy (AFM) were performed. Despite not having a typical amphiphilic molecular structure, the derivatives formed stable films on the water surface. They could also undergo repeated photoisomerization in all of the investigated thin-film configurations. The observations suggest that in the films at the air-water interface, the molecules first exhibit a conformational change, and then they reorient to an energetically more favored orientation. In the LB films transferred onto solid substrates, the isomerization process occurs on a similar time scale as in solution. However, the isomerization efficiency is about an order of magnitude lower than that in solution. Our results show that DNA nucleobases functionalized with azobenzene moieties are suitable candidates for the fabrication of photoactive two-dimensional (2D) materials that can provide all beneficial functionalities of DNA-based compounds.
Collapse
Affiliation(s)
- Matjaž Ličen
- Faculty
of Mathematics and Physics, University of
Ljubljana, Jadranska 19, SI-1000 Ljubljana, Slovenia
| | - Stefano Masiero
- Dipartimento
di Chimica “Giacomo Ciamician”, Alma Mater Studiorum—Università di Bologna, Via San Giacomo 11, I-40126 Bologna, Italy
| | - Silvia Pieraccini
- Dipartimento
di Chimica “Giacomo Ciamician”, Alma Mater Studiorum—Università di Bologna, Via San Giacomo 11, I-40126 Bologna, Italy
| | - Irena Drevenšek-Olenik
- Faculty
of Mathematics and Physics, University of
Ljubljana, Jadranska 19, SI-1000 Ljubljana, Slovenia
- Department
of Complex Matter, Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
| |
Collapse
|
6
|
Musa AM, Kiely J, Luxton R, Honeychurch KC. Recent progress in screen-printed electrochemical sensors and biosensors for the detection of estrogens. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116254] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
7
|
Ielo I, Giacobello F, Sfameni S, Rando G, Galletta M, Trovato V, Rosace G, Plutino MR. Nanostructured Surface Finishing and Coatings: Functional Properties and Applications. MATERIALS (BASEL, SWITZERLAND) 2021; 14:2733. [PMID: 34067241 PMCID: PMC8196899 DOI: 10.3390/ma14112733] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 05/14/2021] [Accepted: 05/19/2021] [Indexed: 02/07/2023]
Abstract
This review presents current literature on different nanocomposite coatings and surface finishing for textiles, and in particular this study has focused on smart materials, drug-delivery systems, industrial, antifouling and nano/ultrafiltration membrane coatings. Each of these nanostructured coatings shows interesting properties for different fields of application. In this review, particular attention is paid to the synthesis and the consequent physico-chemical characteristics of each coating and, therefore, to the different parameters that influence the substrate deposition process. Several techniques used in the characterization of these surface finishing coatings were also described. In this review the sol-gel method for preparing stimuli-responsive coatings as smart sensor materials is described; polymers and nanoparticles sensitive to pH, temperature, phase, light and biomolecules are also treated; nanomaterials based on phosphorus, borates, hydroxy carbonates and silicones are used and described as flame-retardant coatings; organic/inorganic hybrid sol-gel coatings for industrial applications are illustrated; carbon nanotubes, metallic oxides and polymers are employed for nano/ultrafiltration membranes and antifouling coatings. Research institutes and industries have collaborated in the advancement of nanotechnology by optimizing conversion processes of conventional materials into coatings with new functionalities for intelligent applications.
Collapse
Affiliation(s)
- Ileana Ielo
- Institute for the Study of Nanostructured Materials, ISMN–CNR, Palermo, c/o Department of ChiBioFarAm, University of Messina, Viale F. Stagno d’Alcontres 31, Vill. S. Agata, 98166 Messina, Italy; (I.I.); (F.G.); (S.S.)
| | - Fausta Giacobello
- Institute for the Study of Nanostructured Materials, ISMN–CNR, Palermo, c/o Department of ChiBioFarAm, University of Messina, Viale F. Stagno d’Alcontres 31, Vill. S. Agata, 98166 Messina, Italy; (I.I.); (F.G.); (S.S.)
| | - Silvia Sfameni
- Institute for the Study of Nanostructured Materials, ISMN–CNR, Palermo, c/o Department of ChiBioFarAm, University of Messina, Viale F. Stagno d’Alcontres 31, Vill. S. Agata, 98166 Messina, Italy; (I.I.); (F.G.); (S.S.)
- Department of Engineering, University of Messina, Contrada di Dio, S. Agata, 98166 Messina, Italy
| | - Giulia Rando
- Department of Chemical, Biological, Pharmaceutical and Analytical Sciences (ChiBioFarAm), University of Messina, Viale F. Stagno d’Alcontres 31, Vill. S. Agata, 98166 Messina, Italy; (G.R.); (M.G.)
| | - Maurilio Galletta
- Department of Chemical, Biological, Pharmaceutical and Analytical Sciences (ChiBioFarAm), University of Messina, Viale F. Stagno d’Alcontres 31, Vill. S. Agata, 98166 Messina, Italy; (G.R.); (M.G.)
| | - Valentina Trovato
- Department of Engineering and Applied Sciences, University of Bergamo, Viale Marconi 5, 24044 Dalmine (BG), Italy;
| | - Giuseppe Rosace
- Department of Engineering and Applied Sciences, University of Bergamo, Viale Marconi 5, 24044 Dalmine (BG), Italy;
| | - Maria Rosaria Plutino
- Institute for the Study of Nanostructured Materials, ISMN–CNR, Palermo, c/o Department of ChiBioFarAm, University of Messina, Viale F. Stagno d’Alcontres 31, Vill. S. Agata, 98166 Messina, Italy; (I.I.); (F.G.); (S.S.)
| |
Collapse
|
8
|
Tandon S, George SM, McIntyre R, Kandasubramanian B. Polymeric immunosensors for tumor detection. Biomed Phys Eng Express 2020; 6:032001. [PMID: 33438645 DOI: 10.1088/2057-1976/ab8a75] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Cancer is a broad-spectrum disease which is spread globally, having high mortality rates. This results from genetic, epigenetic and molecular abnormalities caused by various mutations. The main reason behind this critical problem lies in its diagnostics, the late detection of the disease is the root cause of all this. This can be managed well by the timely diagnosis of cancer by means of the tumor biomarkers present in the body fluids such as serum, blood, and urine. These tumor biomarkers are present in normal conditions as well, but their concentrations are altered in the presence of a malignant tumor. Prolonged studies have reported that immunosensors can be used to detect the minimal amount of biomarkers present in the sample and also provides point-of-care detection. The recent investigations demonstrated the use of polymers along with immunosensors for enhancing their selectivity and sensitivity towards the biomarkers and making them even more efficient. This review focuses on the variety of tumor biomarkers, different types of immunosensors and polymeric immunosensors using different polymers like polypyrrole, polyaniline, PHEMA, etc.
Collapse
Affiliation(s)
- Saloni Tandon
- Biotechnology Lab, Center for Converging Technologies, University of Rajasthan, JLN Marg, Jaipur-302004, Rajasthan, India
| | | | | | | |
Collapse
|
9
|
Zha YH, Zhou Y. Functional nanomaterials based immunological detection of aflatoxin B1: a review. WORLD MYCOTOXIN J 2020. [DOI: 10.3920/wmj2019.2504] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Aflatoxin B1 (AFB1) is highly carcinogenic, mutagenic and teratogenic. Accordingly, sensitive, rapid and cost-effective techniques for detection of AFB1 is in urgent demand for food safety and the health of consumers. In this review, we report the current state of immunoassay formats and development, mainly based on nanomaterials for determination of AFB1. Following an introduction of the field, the microplate-, membrane- and microelectrode-based immunoassays are described. The relevant mechanisms, sensitivities, superiorities and deficiencies of each format are discussed. Finally, perspectives on the future development of nanomaterials-based immunoassays for AFB1 are provided.
Collapse
Affiliation(s)
- Y.-H. Zha
- Key Laboratory of Zoonoses Research, Ministry of Education, Institute of Zoonosis, College of Veterinary Medicine, Jilin University, Changchun 130062, China P.R
| | - Y. Zhou
- Key Laboratory of Zoonoses Research, Ministry of Education, Institute of Zoonosis, College of Veterinary Medicine, Jilin University, Changchun 130062, China P.R
- College of Animal Sciences, Yangtze University, Jingzhou 434023, China P.R
| |
Collapse
|
10
|
Xiang H, Cai Q, Li Y, Zhang Z, Cao L, Li K, Yang H. Sensors Applied for the Detection of Pesticides and Heavy Metals in Freshwaters. JOURNAL OF SENSORS 2020; 2020:1-22. [DOI: 10.1155/2020/8503491] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Water is essential for every life living on the planet. However, we are facing a more serious situation such as water pollution since the industrial revolution. Fortunately, many efforts have been done to alleviate/restore water quality in freshwaters. Numerous sensors have been developed to monitor the dynamic change of water quality for ecological, early warning, and protection reasons. In the present review, we briefly introduced the pollution status of two major pollutants, i.e., pesticides and heavy metals, in freshwaters worldwide. Then, we collected data on the sensors applied to detect the two categories of pollutants in freshwaters. Special focuses were given on the sensitivity of sensors indicated by the limit of detection (LOD), sensor types, and applied waterbodies. Our results showed that most of the sensors can be applied for stream and river water. The average LOD was72.53±12.69 ng/ml (n=180) for all pesticides, which is significantly higher than that for heavy metals (65.36±47.51 ng/ml,n=117). However, the LODs of a considerable part of pesticides and heavy metal sensors were higher than the criterion maximum concentration for aquatic life or the maximum contaminant limit concentration for drinking water. For pesticide sensors, the average LODs did not differ among insecticides (63.83±17.42 ng/ml,n=87), herbicides (98.06±23.39 ng/ml,n=71), and fungicides (24.60±14.41 ng/ml,n=22). The LODs that differed among sensor types with biosensors had the highest sensitivity, while electrochemical optical and biooptical sensors showed the lowest sensitivity. The sensitivity of heavy metal sensors varied among heavy metals and sensor types. Most of the sensors were targeted on lead, cadmium, mercury, and copper using electrochemical methods. These results imply that future development of pesticides and heavy metal sensors should (1) enhance the sensitivity to meet the requirements for the protection of aquatic ecosystems and human health and (2) cover more diverse pesticides and heavy metals especially those toxic pollutants that are widely used and frequently been detected in freshwaters (e.g., glyphosate, fungicides, zinc, chromium, and arsenic).
Collapse
Affiliation(s)
- Hongyong Xiang
- Key Laboratory of Vegetation Ecology, Ministry of Education, Institute of Grassland Science, Northeast Normal University, Changchun, Jilin 130024, China
- Institute for Ecological Research and Pollution Control of Plateau Lakes, School of Ecology and Environmental Science, Yunnan University, Kunming, Yunnan 650500, China
| | - Qinghua Cai
- State Key Laboratory of Freshwater Ecology and Biotechnology, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, China
| | - Yuan Li
- Northwest Land and Resources Research Center, Shaanxi Normal Northwest University, China
| | - Zhenxing Zhang
- Key Laboratory of Vegetation Ecology, Ministry of Education, Institute of Grassland Science, Northeast Normal University, Changchun, Jilin 130024, China
- State Environmental Protection Key Laboratory of Wetland Ecology and Vegetation Restoration, Northeast Normal University, Changchun, Jilin 130024, China
| | - Lina Cao
- Ecology and Environment Department of Jilin Province, Changchun, Jilin 130024, China
| | - Kun Li
- Heilongjiang Provincial Key Laboratory of Ecological Restoration and Resource Utilization for Cold Region, Heilongjiang University, Harbin 150080, China
| | - Haijun Yang
- Key Laboratory of Vegetation Ecology, Ministry of Education, Institute of Grassland Science, Northeast Normal University, Changchun, Jilin 130024, China
- Institute for Ecological Research and Pollution Control of Plateau Lakes, School of Ecology and Environmental Science, Yunnan University, Kunming, Yunnan 650500, China
- School of Life Science and Geology, Yili Normal University, Yili, Xinjiang 835000, China
| |
Collapse
|
11
|
Schulz K, Pöhlmann C, Dietrich R, Märtlbauer E, Elßner T. An Electrochemical Fiveplex Biochip Assay Based on Anti-Idiotypic Antibodies for Fast On-Site Detection of Bioterrorism Relevant Low Molecular Weight Toxins. Toxins (Basel) 2019; 11:toxins11120696. [PMID: 31795179 PMCID: PMC6950599 DOI: 10.3390/toxins11120696] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 11/22/2019] [Accepted: 11/26/2019] [Indexed: 12/19/2022] Open
Abstract
Modern threats of bioterrorism force the need for multiple detection of biothreat agents to determine the presence or absence of such agents in suspicious samples. Here, we present a rapid electrochemical fiveplex biochip screening assay for detection of the bioterrorism relevant low molecular weight toxins saxitoxin, microcystin-LR, T-2 toxin, roridin A and aflatoxin B1 relying on anti-idiotypic antibodies as epitope-mimicking reagents. The proposed method avoids the use of potentially harmful toxin-protein conjugates usually mandatory for competitive immunoassays. The biochip is processed and analyzed on the automated and portable detection platform pBDi within 13.4 min. The fiveplex biochip assay revealed toxin group specificity to multiple congeners. Limits of detection were 1.2 ng/mL, 1.5 ng/mL, 0.4 ng/mL, 0.5 ng/mL and 0.6 ng/mL for saxitoxin, microcystin-LR, T-2 toxin, roridin A or aflatoxin B1, respectively. The robustness of the fiveplex biochip for real samples was demonstrated by detecting saxitoxin, microcystin-LR, HT-2 toxin, roridin A and aflatoxin B1 in contaminated human blood serum without elaborate sample preparation. Recovery rates were between 52–115% covering a wide concentration range. Thus, the developed robust fiveplex biochip assay can be used on-site to quickly detect one or multiple low molecular weight toxins in a single run.
Collapse
Affiliation(s)
- Katharina Schulz
- Bruker Daltonik GmbH, Permoserstr. 15, 04318 Leipzig, Germany; (K.S.); (C.P.); (T.E.)
- Department of Veterinary Sciences, Faculty of Veterinary Medicine, Ludwig-Maximilians-Universität München, Schönleutnerstr. 8, 85764 Oberschleißheim, Germany;
| | - Christopher Pöhlmann
- Bruker Daltonik GmbH, Permoserstr. 15, 04318 Leipzig, Germany; (K.S.); (C.P.); (T.E.)
| | - Richard Dietrich
- Department of Veterinary Sciences, Faculty of Veterinary Medicine, Ludwig-Maximilians-Universität München, Schönleutnerstr. 8, 85764 Oberschleißheim, Germany;
| | - Erwin Märtlbauer
- Department of Veterinary Sciences, Faculty of Veterinary Medicine, Ludwig-Maximilians-Universität München, Schönleutnerstr. 8, 85764 Oberschleißheim, Germany;
- Correspondence:
| | - Thomas Elßner
- Bruker Daltonik GmbH, Permoserstr. 15, 04318 Leipzig, Germany; (K.S.); (C.P.); (T.E.)
| |
Collapse
|
12
|
Abu-Ali H, Nabok A, Smith TJ, Al-Shanawa M. Development of a Novel Electrochemical Inhibition Sensor Array Based on Bacteria Immobilized on Modified Screen-Printed Gold Electrodes for Water Pollution Detection. BIONANOSCIENCE 2019. [DOI: 10.1007/s12668-019-00619-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
13
|
Eom H, Hwang JH, Hassan SH, Joo JH, Hur JH, Chon K, Jeon BH, Song YC, Chae KJ, Oh SE. Rapid detection of heavy metal-induced toxicity in water using a fed-batch sulfur-oxidizing bacteria (SOB) bioreactor. J Microbiol Methods 2019; 161:35-42. [DOI: 10.1016/j.mimet.2019.04.007] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 04/04/2019] [Accepted: 04/07/2019] [Indexed: 02/09/2023]
|
14
|
Min X, Bao C, Kim WS. Additively Manufactured Digital Microfluidic Platforms for Ion-Selective Sensing. ACS Sens 2019; 4:918-923. [PMID: 30855128 DOI: 10.1021/acssensors.8b01689] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Digital microfluidic (DMF) sensors integrated with circuit systems have been applied to a broad range of applications including biology, medicine, and chemistry. Compared with the conventional microfluidic devices that require extra liquid as a carrier and a complex pumping system to operate, DMF is an ideal platform for ion-selective sensing as it enables the droplet operation in a discrete, accurate, and automatic way. However, it is quite rare that DMF platform is utilized for the ion-selective detection. In this paper, we report an integrated DMF system which combines DMF and ion-selective sensing for facile blending of multiple ions, and detection of targeted primary ion. The platform is fabricated through an additive manufacturing method, together with the real-time droplet's motion monitoring feedback system. Thus, the fabricated system demonstrates controlled droplet manipulation ability including droplet actuation, mixing, and speed control. Targeted primary ion is selectively detected under concentration range from 10-6 to 1 M. The interference study with blended ions has been investigated through on-chip ion selective membranes.
Collapse
Affiliation(s)
- Xin Min
- Additive Manufacturing Laboratory, School of Mechatronic Systems Engineering, Simon Fraser University, Surrey, British Columbia V3T 0A3, Canada
| | - Chao Bao
- Additive Manufacturing Laboratory, School of Mechatronic Systems Engineering, Simon Fraser University, Surrey, British Columbia V3T 0A3, Canada
| | - Woo Soo Kim
- Additive Manufacturing Laboratory, School of Mechatronic Systems Engineering, Simon Fraser University, Surrey, British Columbia V3T 0A3, Canada
| |
Collapse
|
15
|
Schulz K, Pöhlmann C, Dietrich R, Märtlbauer E, Elßner T. Electrochemical Biochip Assays Based on Anti-idiotypic Antibodies for Rapid and Automated On-Site Detection of Low Molecular Weight Toxins. Front Chem 2019; 7:31. [PMID: 30775361 PMCID: PMC6367258 DOI: 10.3389/fchem.2019.00031] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2018] [Accepted: 01/14/2019] [Indexed: 01/03/2023] Open
Abstract
Phycotoxins and mycotoxins, such as paralytic shellfish poisoning toxins, type A trichothecenes, and aflatoxins are among the most toxic low molecular weight toxins associated with human poisoning incidents through the consumption of naturally contaminated food. Therefore, there is an utmost need for rapid and sensitive on-site detection systems. Herein, an electrochemical biochip for fast detection of saxitoxin, T-2 toxin as well as aflatoxin M1 and their corresponding congeners, respectively, using a portable and fully automated detection platform (pBDi, portable BioDetector integrated) was developed. Toxin analysis is facilitated upon the biochip via an indirect competitive immunoassay using toxin-specific antibodies combined with anti-idiotypic antibodies. The developed biochips enable detection in the low ng/mL-range within 17 min. Moreover, the assays cover a wide linear working range of 2–3 orders of magnitude above the limit of detection with an inter-chip coefficient of variation lower than 15%. The broad specificity of the employed antibodies which react with a large number of congeners within the respective toxin group allows efficient screening of contaminated samples for the presence of these low molecular weight toxins. With respect to the analysis of human urine samples, we focused here on the detection of saxitoxin, HT-2 toxin, and aflatoxin M1, all known as biomarkers of acute toxin exposure. Overall, it was proved that the developed biochip assays can be used to rapidly and reliably identify severe intoxications caused by these low molecular weight toxins.
Collapse
Affiliation(s)
- Katharina Schulz
- Bruker Daltonik GmbH, Leipzig, Germany.,Department of Veterinary Sciences, Faculty of Veterinary Medicine, Ludwig-Maximilians-Universität München, Munich, Germany
| | | | - Richard Dietrich
- Department of Veterinary Sciences, Faculty of Veterinary Medicine, Ludwig-Maximilians-Universität München, Munich, Germany
| | - Erwin Märtlbauer
- Department of Veterinary Sciences, Faculty of Veterinary Medicine, Ludwig-Maximilians-Universität München, Munich, Germany
| | | |
Collapse
|
16
|
Eftekhari A, Hasanzadeh M, Sharifi S, Dizaj SM, Khalilov R, Ahmadian E. Bioassay of saliva proteins: The best alternative for conventional methods in non-invasive diagnosis of cancer. Int J Biol Macromol 2018; 124:1246-1255. [PMID: 30513307 DOI: 10.1016/j.ijbiomac.2018.11.277] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2018] [Revised: 11/28/2018] [Accepted: 11/30/2018] [Indexed: 12/29/2022]
Abstract
Non-invasive diagnosis of cancer is often the key to effective treatment and patient survival. Saliva as a multi-constituent oral fluid comprises various disease signaling biomarkers, holds great potential for early-stage cancer diagnostics with cost-effective and easy collection, storage, transport and processing. Therefore, detection of biomarkers and proteins in the saliva samples is highly demand. The current review was performed using reliable internet database (mainly PubMed) to provide an overview of the most recent developments on non-invasive diagnosis of cancers in saliva and highlights main challenges and future prospects in sensing of the salivary biomarkers. The conventional detection methods of cancer biomarkers in saliva is discussed in the paper, however, the main focus is on non-invasive diagnosis of cancers in saliva using immunosensing (electrochemical, optical, piezoelectric), DNA based sensors, aptasensors and peptide based bio-assays The reviewed literature revealed that non-invasive cancer detection methods using the mentioned biosensors and without any processing of saliva sample offers a quick, sensitive, specific and cost effective analytical tool. Besides, salivary based detection methods can be used for simultaneous detection of panels of disease specific biomarkers in a real time manner or as home testing kits in near future.
Collapse
Affiliation(s)
- Aziz Eftekhari
- Pharmacology and Toxicology Department, Maragheh University of Medical Sciences, Maragheh, Iran
| | - Mohammad Hasanzadeh
- Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz 51664, Iran.
| | - Simin Sharifi
- Dental and Periodontal Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Solmaz Maleki Dizaj
- Dental and Periodontal Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Rovshan Khalilov
- Joint Ukrainian-Azerbaijan International Research and Education Center of Nanobiotechnology and Functional Nanosystems, Drohobych Ukraine & Baku, Azerbaijan, Institute of Radiation Problems of NAS Azerbaijan, Baku, Azerbaijan
| | - Elham Ahmadian
- Dental and Periodontal Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; Students' Research Committee, Tabriz University of Medical Sciences, Tabriz, Iran.
| |
Collapse
|
17
|
Qu Z, Li N, Na W, Su X. A novel fluorescence "turn off-on" nanosensor for sensitivity detection acid phosphatase and inhibitor based on glutathione-functionalized graphene quantum dots. Talanta 2018; 192:61-68. [PMID: 30348430 DOI: 10.1016/j.talanta.2018.09.009] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 08/28/2018] [Accepted: 09/03/2018] [Indexed: 12/31/2022]
Abstract
In this paper, we developed a label-free and sensitive fluorescence sensor for acid phosphatase (ACP) and its inhibitor parathion-methyl (PM) detection based on glutathione-functionalized graphene quantum dots (GQDs@GSH). Upon addition of MnO2 nanosheets, the fluorescence of GQDs@GSH could be efficiently quenched via a fluorescence resonance energy transfer. ACP could easily catalyze the hydrolysis of L-Ascorbic acid-2-phosphate (AAP) to ascorbic acid (AA), which could reduce MnO2 nanosheets to Mn2+ in acidic environment, leading to dramatically increase of the fluorescence intensity of GQDs@GSH. Quantitative detection of ACP in a broad range from 0.1 to 9 mU mL-1 with a detection limit of 0.027 mU mL-1 could be achieved. The feasibility of the proposed sensor in real samples analysis was also studied and satisfactory results were obtained. Furthermore, the fluorescence assay strategy could also be used for the detection of parathion-methyl (PM) as ACP inhibitor.
Collapse
Affiliation(s)
- Zhengyi Qu
- Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun 130012, China
| | - Ning Li
- Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun 130012, China; Department of Respiratory, China-Japan Union Hospital of Jilin University, Changchun 130012, China
| | - Weidan Na
- Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun 130012, China
| | - Xingguang Su
- Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun 130012, China.
| |
Collapse
|
18
|
A novel fluorimetric sensing strategy for highly sensitive detection of phytic acid and hydrogen peroxide. Anal Chim Acta 2018; 1039:74-81. [PMID: 30322555 DOI: 10.1016/j.aca.2018.07.030] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2018] [Revised: 07/09/2018] [Accepted: 07/13/2018] [Indexed: 01/14/2023]
Abstract
In this paper, we developed a sensitive sensor for phytic acid (PA) and hydrogen peroxide (H2O2) detection based on glutathione-functionalized graphene quantum dots (GQDs@GSH). The fluorescence of GQDs@GSH was found to be effectively quenched by Fe3+ ions via photo-induced electron transfer (PET) process. Upon the addition of PA to GQDs@GSH/Fe3+ system, the fluorescence of GQDs@GSH was significantly restored due to the strong chelating and reducing ability of PA, Fe3+ ions could be reduced to Fe2+ ions by PA and formed PA/Fe2+ complex. Therefore, the "off-on" fluorescence method was constructed to detect PA by using GQDs@GSH/Fe3+ as a fluorescent probe. Furthermore, the method can be used for the detection of H2O2. H2O2 can destroy the chelate structure of PA/Fe2+, release Fe2+ ions and oxidize Fe2+ ions to produce Fe3+ ions, leading to the fluorescence quenching of GQDs@GSH again. Under optimal conditions, the fluorescence sensing platform showed good linear relationship between the relative fluorescence intensity I/I0 and the concentration of PA and H2O2 in the range of 0.05-3 μmol L-1 and 0.5-10 μmol L-1, respectively. The detection limits of PA and H2O2 were 14 nmol L-1 and 0.134 μmol L-1, respectively. Furthermore, the fluorescence assay method was also applied in real sample analysis and satisfactory results were obtained.
Collapse
|
19
|
Mazurenko S, Bidmanova S, Kotlanova M, Damborsky J, Prokop Z. Sensitive operation of enzyme-based biodevices by advanced signal processing. PLoS One 2018; 13:e0198913. [PMID: 29912920 PMCID: PMC6005535 DOI: 10.1371/journal.pone.0198913] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Accepted: 05/29/2018] [Indexed: 12/26/2022] Open
Abstract
Analytical devices that combine sensitive biological component with a physicochemical detector hold a great potential for various applications, e.g., environmental monitoring, food analysis or medical diagnostics. Continuous efforts to develop inexpensive sensitive biodevices for detecting target substances typically focus on the design of biorecognition elements and their physical implementation, while the methods for processing signals generated by such devices have received far less attention. Here, we present fundamental considerations related to signal processing in biosensor design and investigate how undemanding signal treatment facilitates calibration and operation of enzyme-based biodevices. Our signal treatment approach was thoroughly validated with two model systems: (i) a biodevice for detecting chemical warfare agents and environmental pollutants based on the activity of haloalkane dehalogenase, with the sensitive range for bis(2-chloroethyl) ether of 0.01–0.8 mM and (ii) a biodevice for detecting hazardous pesticides based on the activity of γ-hexachlorocyclohexane dehydrochlorinase with the sensitive range for γ-hexachlorocyclohexane of 0.01–0.3 mM. We demonstrate that the advanced signal processing based on curve fitting enables precise quantification of parameters important for sensitive operation of enzyme-based biodevices, including: (i) automated exclusion of signal regions with substantial noise, (ii) derivation of calibration curves with significantly reduced error, (iii) shortening of the detection time, and (iv) reliable extrapolation of the signal to the initial conditions. The presented simple signal curve fitting supports rational design of optimal system setup by explicit and flexible quantification of its properties and will find a broad use in the development of sensitive and robust biodevices.
Collapse
Affiliation(s)
- Stanislav Mazurenko
- Loschmidt Laboratories, Department of Experimental Biology and Research Centre for Toxic Compounds in the Environment RECETOX, Masaryk University, Brno, Czech Republic
| | - Sarka Bidmanova
- Loschmidt Laboratories, Department of Experimental Biology and Research Centre for Toxic Compounds in the Environment RECETOX, Masaryk University, Brno, Czech Republic
- International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic
| | - Marketa Kotlanova
- Loschmidt Laboratories, Department of Experimental Biology and Research Centre for Toxic Compounds in the Environment RECETOX, Masaryk University, Brno, Czech Republic
- Enantis, s r.o., Brno, Czech Republic
| | - Jiri Damborsky
- Loschmidt Laboratories, Department of Experimental Biology and Research Centre for Toxic Compounds in the Environment RECETOX, Masaryk University, Brno, Czech Republic
- International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic
| | - Zbynek Prokop
- Loschmidt Laboratories, Department of Experimental Biology and Research Centre for Toxic Compounds in the Environment RECETOX, Masaryk University, Brno, Czech Republic
- International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic
- * E-mail:
| |
Collapse
|
20
|
Monteiro T, Almeida MG. Electrochemical Enzyme Biosensors Revisited: Old Solutions for New Problems. Crit Rev Anal Chem 2018; 49:44-66. [PMID: 29757683 DOI: 10.1080/10408347.2018.1461552] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
Worldwide legislation is driving the development of novel and highly efficient analytical tools for assessing the composition of every material that interacts with Consumers or Nature. The biosensor technology is one of the most active R&D domains of Analytical Sciences focused on the challenge of taking analytical chemistry to the field. Electrochemical biosensors based on redox enzymes, in particular, are highly appealing due to their usual quick response, high selectivity and sensitivity, low cost and portable dimensions. This review paper aims to provide an overview of the most important advances made in the field since the proposal of the first biosensor, the well-known hand-held glucose meter. The first section addresses the current needs and challenges for novel analytical tools, followed by a brief description of the different components and configurations of biosensing devices, and the fundamentals of enzyme kinetics and amperometry. The following sections emphasize on enzyme-based amperometric biosensors and the different stages of their development.
Collapse
Affiliation(s)
- Tiago Monteiro
- a UCIBIO-REQUIMTE, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa , Caparica , Portugal
| | | |
Collapse
|
21
|
Sample treatment procedures for environmental sensing and biosensing. Curr Opin Biotechnol 2017; 45:170-174. [DOI: 10.1016/j.copbio.2017.02.017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2017] [Revised: 02/24/2017] [Accepted: 02/28/2017] [Indexed: 01/15/2023]
|
22
|
Dumas E, Giraudo M, Goujon E, Halma M, Knhili E, Stauffert M, Batisson I, Besse-Hoggan P, Bohatier J, Bouchard P, Celle-Jeanton H, Costa Gomes M, Delbac F, Forano C, Goupil P, Guix N, Husson P, Ledoigt G, Mallet C, Mousty C, Prévot V, Richard C, Sarraute S. Fate and ecotoxicological impact of new generation herbicides from the triketone family: An overview to assess the environmental risks. JOURNAL OF HAZARDOUS MATERIALS 2017; 325:136-156. [PMID: 27930998 DOI: 10.1016/j.jhazmat.2016.11.059] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2016] [Revised: 10/21/2016] [Accepted: 11/19/2016] [Indexed: 06/06/2023]
Abstract
Triketones, derived chemically from a natural phytotoxin (leptospermone), are a good example of allelochemicals as lead molecules for the development of new herbicides. Targeting a new and key enzyme involved in carotenoid biosynthesis, these latest-generation herbicides (sulcotrione, mesotrione and tembotrione) were designed to be eco-friendly and commercialized fifteen-twenty years ago. The mechanisms controlling their fate in different ecological niches as well as their toxicity and impact on different organisms or ecosystems are still under investigation. This review combines an overview of the results published in the literature on β-triketones and more specifically, on the commercially-available herbicides and includes new results obtained in our interdisciplinary study aiming to understand all the processes involved (i) in their transfer from the soil to the connected aquatic compartments, (ii) in their transformation by photochemical and biological mechanisms but also to evaluate (iii) the impacts of the parent molecules and their transformation products on various target and non-target organisms (aquatic microorganisms, plants, soil microbial communities). Analysis of all the data on the fate and impact of these molecules, used pure, as formulation or in cocktails, give an overall guide for the assessment of their environmental risks.
Collapse
Affiliation(s)
- E Dumas
- Clermont Université, Université Blaise Pascal, Institut de Chimie de Clermont-Ferrand, BP 10448, 63000 Clermont-Ferrand, France; CNRS, UMR 6296, ICCF, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - M Giraudo
- Clermont Université, Université Blaise Pascal-Université d'Auvergne, Laboratoire Microorganismes: Génome et Environnement, BP 10448, 63000 Clermont Ferrand, France; CNRS, UMR 6023, LMGE, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - E Goujon
- Clermont Université, Université Blaise Pascal, Physique et Physiologie Intégratives de l'Arbre Fruitier et Forestier, 63000 Clermont-Ferrand, France; INRA, UMR PIAF 547, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - M Halma
- Clermont Université, Université Blaise Pascal, Institut de Chimie de Clermont-Ferrand, BP 10448, 63000 Clermont-Ferrand, France; CNRS, UMR 6296, ICCF, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - E Knhili
- Clermont Université, Université Blaise Pascal, Institut de Chimie de Clermont-Ferrand, BP 10448, 63000 Clermont-Ferrand, France; CNRS, UMR 6296, ICCF, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - M Stauffert
- Clermont Université, Université Blaise Pascal, Institut de Chimie de Clermont-Ferrand, BP 10448, 63000 Clermont-Ferrand, France; CNRS, UMR 6296, ICCF, TSA 60026, CS 60026, 63178 Aubière Cedex, France; Clermont Université, Université Blaise Pascal-Université d'Auvergne, Laboratoire Microorganismes: Génome et Environnement, BP 10448, 63000 Clermont Ferrand, France; CNRS, UMR 6023, LMGE, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - I Batisson
- Clermont Université, Université Blaise Pascal-Université d'Auvergne, Laboratoire Microorganismes: Génome et Environnement, BP 10448, 63000 Clermont Ferrand, France; CNRS, UMR 6023, LMGE, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - P Besse-Hoggan
- Clermont Université, Université Blaise Pascal, Institut de Chimie de Clermont-Ferrand, BP 10448, 63000 Clermont-Ferrand, France; CNRS, UMR 6296, ICCF, TSA 60026, CS 60026, 63178 Aubière Cedex, France.
| | - J Bohatier
- Clermont Université, Université Blaise Pascal-Université d'Auvergne, Laboratoire Microorganismes: Génome et Environnement, BP 10448, 63000 Clermont Ferrand, France; CNRS, UMR 6023, LMGE, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - P Bouchard
- Clermont Université, Université Blaise Pascal-Université d'Auvergne, Laboratoire Microorganismes: Génome et Environnement, BP 10448, 63000 Clermont Ferrand, France; CNRS, UMR 6023, LMGE, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - H Celle-Jeanton
- Clermont Université, Université Blaise Pascal, Laboratoire Magmas et Volcans, BP 10448, 63000 Clermont-Ferrand, France; CNRS, UMR 6524, LMV, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - M Costa Gomes
- Clermont Université, Université Blaise Pascal, Institut de Chimie de Clermont-Ferrand, BP 10448, 63000 Clermont-Ferrand, France; CNRS, UMR 6296, ICCF, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - F Delbac
- Clermont Université, Université Blaise Pascal-Université d'Auvergne, Laboratoire Microorganismes: Génome et Environnement, BP 10448, 63000 Clermont Ferrand, France; CNRS, UMR 6023, LMGE, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - C Forano
- Clermont Université, Université Blaise Pascal, Institut de Chimie de Clermont-Ferrand, BP 10448, 63000 Clermont-Ferrand, France; CNRS, UMR 6296, ICCF, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - P Goupil
- Clermont Université, Université Blaise Pascal, Physique et Physiologie Intégratives de l'Arbre Fruitier et Forestier, 63000 Clermont-Ferrand, France; INRA, UMR PIAF 547, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - N Guix
- INRA, UMR 1095 Génétique, Diversité et Ecophysiologie des Céréales, 5 chemin de Beaulieu, 63039 Clermont-Ferrand, France; VetAgro Sup, 89 avenue de l'Europe, BP 35, 63370 Lempdes, France; UMR Génétique Diversité et Ecophysiologie des Céréales, INRA-UBP, UMR 1095, 63000 Clermont-Ferrand, France
| | - P Husson
- Clermont Université, Université Blaise Pascal, Institut de Chimie de Clermont-Ferrand, BP 10448, 63000 Clermont-Ferrand, France; CNRS, UMR 6296, ICCF, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - G Ledoigt
- Clermont Université, Université Blaise Pascal, Physique et Physiologie Intégratives de l'Arbre Fruitier et Forestier, 63000 Clermont-Ferrand, France; INRA, UMR PIAF 547, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - C Mallet
- Clermont Université, Université Blaise Pascal-Université d'Auvergne, Laboratoire Microorganismes: Génome et Environnement, BP 10448, 63000 Clermont Ferrand, France; CNRS, UMR 6023, LMGE, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - C Mousty
- Clermont Université, Université Blaise Pascal, Institut de Chimie de Clermont-Ferrand, BP 10448, 63000 Clermont-Ferrand, France; CNRS, UMR 6296, ICCF, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - V Prévot
- Clermont Université, Université Blaise Pascal, Institut de Chimie de Clermont-Ferrand, BP 10448, 63000 Clermont-Ferrand, France; CNRS, UMR 6296, ICCF, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - C Richard
- Clermont Université, Université Blaise Pascal, Institut de Chimie de Clermont-Ferrand, BP 10448, 63000 Clermont-Ferrand, France; CNRS, UMR 6296, ICCF, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| | - S Sarraute
- Clermont Université, Université Blaise Pascal, Institut de Chimie de Clermont-Ferrand, BP 10448, 63000 Clermont-Ferrand, France; CNRS, UMR 6296, ICCF, TSA 60026, CS 60026, 63178 Aubière Cedex, France
| |
Collapse
|
23
|
Justino CI, Duarte AC, Rocha-Santos TA. Critical overview on the application of sensors and biosensors for clinical analysis. Trends Analyt Chem 2016; 85:36-60. [PMID: 32287540 PMCID: PMC7112812 DOI: 10.1016/j.trac.2016.04.004] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Sensors and biosensors have been increasingly used for clinical analysis due to their miniaturization and portability, allowing the construction of diagnostic devices for point-of-care testing. This paper presents an up-to-date overview and comparison of the analytical performance of sensors and biosensors recently used in clinical analysis. This includes cancer and cardiac biomarkers, hormones, biomolecules, neurotransmitters, bacteria, virus and cancer cells, along with related significant advances since 2011. Some methods of enhancing the analytical performance of sensors and biosensors through their figures of merit are also discussed.
Collapse
Affiliation(s)
- Celine I.L. Justino
- Department of Chemistry & CESAM, University of Aveiro, Campus de Santiago, 3810-193 Aveiro, Portugal
- ISEIT/Viseu, Instituto Piaget, Estrada do Alto do Gaio, Galifonge, 3515-776 Lordosa, Viseu, Portugal
| | - Armando C. Duarte
- Department of Chemistry & CESAM, University of Aveiro, Campus de Santiago, 3810-193 Aveiro, Portugal
| | - Teresa A.P. Rocha-Santos
- Department of Chemistry & CESAM, University of Aveiro, Campus de Santiago, 3810-193 Aveiro, Portugal
| |
Collapse
|
24
|
Benito-Peña E, Valdés MG, Glahn-Martínez B, Moreno-Bondi MC. Fluorescence based fiber optic and planar waveguide biosensors. A review. Anal Chim Acta 2016; 943:17-40. [PMID: 27769374 PMCID: PMC7094704 DOI: 10.1016/j.aca.2016.08.049] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2016] [Revised: 08/25/2016] [Accepted: 08/29/2016] [Indexed: 12/21/2022]
Abstract
The application of optical biosensors, specifically those that use optical fibers and planar waveguides, has escalated throughout the years in many fields, including environmental analysis, food safety and clinical diagnosis. Fluorescence is, without doubt, the most popular transducer signal used in these devices because of its higher selectivity and sensitivity, but most of all due to its wide versatility. This paper focuses on the working principles and configurations of fluorescence-based fiber optic and planar waveguide biosensors and will review biological recognition elements, sensing schemes, as well as some major and recent applications, published in the last ten years. The main goal is to provide the reader a general overview of a field that requires the joint collaboration of researchers of many different areas, including chemistry, physics, biology, engineering, and material science.
Collapse
Affiliation(s)
- Elena Benito-Peña
- Department of Analytical Chemistry, Faculty of Chemistry, Complutense University, 28040 Madrid, Spain
| | - Mayra Granda Valdés
- Department of Analytical Chemistry, Faculty of Chemistry, University of La Habana, 10400 La Habana, Cuba
| | - Bettina Glahn-Martínez
- Department of Analytical Chemistry, Faculty of Chemistry, Complutense University, 28040 Madrid, Spain
| | - Maria C Moreno-Bondi
- Department of Analytical Chemistry, Faculty of Chemistry, Complutense University, 28040 Madrid, Spain.
| |
Collapse
|
25
|
Lam CN, Yao H, Olsen BD. The Effect of Protein Electrostatic Interactions on Globular Protein–Polymer Block Copolymer Self-Assembly. Biomacromolecules 2016; 17:2820-9. [DOI: 10.1021/acs.biomac.6b00522] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Christopher N. Lam
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Helen Yao
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Bradley D. Olsen
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| |
Collapse
|
26
|
Malvano F, Albanese D, Crescitelli A, Pilloton R, Esposito E. Impedimetric Label-Free Immunosensor on Disposable Modified Screen-Printed Electrodes for Ochratoxin A. BIOSENSORS-BASEL 2016; 6:bios6030033. [PMID: 27376339 PMCID: PMC5039652 DOI: 10.3390/bios6030033] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Revised: 06/07/2016] [Accepted: 06/23/2016] [Indexed: 12/29/2022]
Abstract
An impedimetric label-free immunosensor on disposable screen-printed carbon electrodes (SPCE) for quantitative determination of Ochratoxin A (OTA) has been developed. After modification of the SPCE surface with gold nanoparticles (AuNPs), the anti-OTA was immobilized on the working electrode through a cysteamine layer. After each coating step, the modified surfaces were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The capacitance was chosen as the best parameter that describes the reproducible change in electrical properties of the electrode surface at different OTA concentrations and it was used to investigate the analytical parameters of the developed immunosensor. Under optimized conditions, the immunosensor showed a linear relationship between 0.3 and 20 ng/mL with a low detection limit of 0.25 ng/mL, making it suitable to control OTA content in many common food products. Lastly, the immunosensor was used to measure OTA in red wine samples and the results were compared with those registered with a competitive ELISA kit. The immunosensor was sensitive to OTA lower than 2 μg/kg, which represents the lower acceptable limit of OTA established by European legislation for common food products.
Collapse
Affiliation(s)
- Francesca Malvano
- Department of Industrial Engineering, University of Salerno, 84084 Fisciano SA, Italy.
| | - Donatella Albanese
- Department of Industrial Engineering, University of Salerno, 84084 Fisciano SA, Italy.
| | - Alessio Crescitelli
- Institute for Microelectronics and Microsystems of the National Council of Research (CNR), 80131 Napoli, Italy.
| | - Roberto Pilloton
- Institute of Atmospheric Pollution Research of the National Council of Research (CNR), 00015 Roma, Italy.
| | - Emanuela Esposito
- Institute for Microelectronics and Microsystems of the National Council of Research (CNR), 80131 Napoli, Italy.
| |
Collapse
|
27
|
Efremenko EN, Maslova OV, Kholstov AV, Senko OV, Ismailov AD. Biosensitive element in the form of immobilized luminescent photobacteria for detecting ecotoxicants in aqueous flow-through systems. LUMINESCENCE 2016; 31:1283-9. [DOI: 10.1002/bio.3104] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2015] [Revised: 11/16/2015] [Accepted: 01/06/2016] [Indexed: 12/16/2022]
|
28
|
Verma N, Kaur G. Trends on Biosensing Systems for Heavy Metal Detection. BIOSENSORS FOR SUSTAINABLE FOOD - NEW OPPORTUNITIES AND TECHNICAL CHALLENGES 2016. [DOI: 10.1016/bs.coac.2016.04.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
29
|
Progress in the biosensing techniques for trace-level heavy metals. Biotechnol Adv 2016; 34:47-60. [DOI: 10.1016/j.biotechadv.2015.12.001] [Citation(s) in RCA: 65] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2015] [Revised: 11/21/2015] [Accepted: 12/02/2015] [Indexed: 01/08/2023]
|
30
|
Abstract
The application of simple, cost-effective, rapid, and accurate diagnostic technologies for detection and identification of cardiac and cancer biomarkers has been a central point in the clinical area. Biosensors have been recognized as efficient alternatives for the diagnostics of various diseases due to their specificity and potential for application on real samples. The role of nanotechnology in the construction of immunological biosensors, that is, immunosensors, has contributed to the improvement of sensitivity, since they are based in the affinity between antibody and antigen. Other analytes than biomarkers such as hormones, pathogenic bacteria, and virus have also been detected by immunosensors for clinical point-of-care applications. In this chapter, we first introduced the various types of immunosensors and discussed their applications in clinical diagnostics over the recent 6 years, mainly as point-of-care technologies for the determination of cardiac and cancer biomarkers, hormones, pathogenic bacteria, and virus. The future perspectives of these devices in the field of clinical diagnostics are also evaluated.
Collapse
|
31
|
Gilani RA, Rafique M, Rehman A, Munis MFH, Rehman SU, Chaudhary HJ. Biodegradation of chlorpyrifos by bacterial genusPseudomonas. J Basic Microbiol 2015; 56:105-19. [DOI: 10.1002/jobm.201500336] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2015] [Accepted: 10/25/2015] [Indexed: 11/11/2022]
Affiliation(s)
- Razia Alam Gilani
- Department of Plant Sciences, Faculty of Biological Sciences; Quaid-i-Azam University; Islamabad Pakistan
| | - Mazhar Rafique
- Department of Plant Sciences, Faculty of Biological Sciences; Quaid-i-Azam University; Islamabad Pakistan
| | - Abdul Rehman
- Department of Microbiology and Molecular Genetics; Punjab University; Lahore Pakistan
| | | | - Shafiq ur Rehman
- College of Earth and Environmental Sciences; Punjab University; Lahore Pakistan
| | - Hassan Javed Chaudhary
- Department of Plant Sciences, Faculty of Biological Sciences; Quaid-i-Azam University; Islamabad Pakistan
| |
Collapse
|
32
|
|
33
|
Rovina K, Siddiquee S, Wong NK. Development of melamine sensor based on ionic liquid/nanoparticles/chitosan with modified gold electrode for determination of melamine in milk product. SENSING AND BIO-SENSING RESEARCH 2015. [DOI: 10.1016/j.sbsr.2015.02.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
|
34
|
Snopok B, Kruglenko I. Analyte induced water adsorbability in gas phase biosensors: the influence of ethinylestradiol on the water binding protein capacity. Analyst 2015; 140:3225-32. [DOI: 10.1039/c4an02121e] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The response of a gas phase biosensor for 17α – ethinylestradiol is due to the change in the water-binding capacity of proteins induced by the binding of ETED molecules.
Collapse
Affiliation(s)
- Borys Snopok
- V. Lashkaryov Institute of Semiconductor Physics
- NAS Ukraine
- Kyiv
- Ukraine
| | - Ivanna Kruglenko
- V. Lashkaryov Institute of Semiconductor Physics
- NAS Ukraine
- Kyiv
- Ukraine
| |
Collapse
|
35
|
Oliveira TM, Barroso MF, Morais S, Araújo M, Freire C, de Lima-Neto P, Correia AN, Oliveira MB, Delerue-Matos C. Sensitive bi-enzymatic biosensor based on polyphenoloxidases–gold nanoparticles–chitosan hybrid film–graphene doped carbon paste electrode for carbamates detection. Bioelectrochemistry 2014; 98:20-9. [DOI: 10.1016/j.bioelechem.2014.02.003] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2013] [Revised: 02/03/2014] [Accepted: 02/22/2014] [Indexed: 02/07/2023]
|
36
|
Electrochemical affinity biosensors for detection of mycotoxins: A review. Biosens Bioelectron 2013; 49:146-58. [PMID: 23743326 DOI: 10.1016/j.bios.2013.05.008] [Citation(s) in RCA: 195] [Impact Index Per Article: 17.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2013] [Revised: 04/26/2013] [Accepted: 05/02/2013] [Indexed: 11/22/2022]
Abstract
This review discusses the current state of electrochemical biosensors in the determination of mycotoxins in foods. Mycotoxins are highly toxic secondary metabolites produced by molds. The acute toxicity of these results in serious human and animal health problems, although it has been only since early 1960s when the first studied aflatoxins were found to be carcinogenic. Mycotoxins affect a broad range of agricultural products, most important cereals and cereal-based foods. A majority of countries, mentioning especially the European Union, have established preventive programs to control contamination and strict laws of the permitted levels in foods. Official methods of analysis of mycotoxins normally requires sophisticated instrumentation, e.g. liquid chromatography with fluorescence or mass detectors, combined with extraction procedures for sample preparation. For about sixteen years, the use of simpler and faster analytical procedures based on affinity biosensors has emerged in scientific literature as a very promising alternative, particularly electrochemical (i.e., amperometric, impedance, potentiometric or conductimetric) affinity biosensors due to their simplicity and sensitivity. Typically, electrochemical biosensors for mycotoxins use specific antibodies or aptamers as affinity ligands, although recombinant antibodies, artificial receptors and molecular imprinted polymers show potential utility. This article deals with recent advances in electrochemical affinity biosensors for mycotoxins and covers complete literature from the first reports about sixteen years ago.
Collapse
|
37
|
Oliveira TMBF, Fátima Barroso M, Morais S, de Lima-Neto P, Correia AN, Oliveira MBPP, Delerue-Matos C. Biosensor based on multi-walled carbon nanotubes paste electrode modified with laccase for pirimicarb pesticide quantification. Talanta 2013; 106:137-43. [PMID: 23598106 DOI: 10.1016/j.talanta.2012.12.017] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2012] [Revised: 12/05/2012] [Accepted: 12/08/2012] [Indexed: 10/27/2022]
Abstract
This study focused on the development of a sensitive enzymatic biosensor for the determination of pirimicarb pesticide based on the immobilization of laccase on composite carbon paste electrodes. Multi-walled carbon nanotubes (MWCNTs) paste electrode modified by dispersion of laccase (3%, w/w) within the optimum composite matrix (60:40%, w/w, MWCNTs and paraffin binder) showed the best performance, with excellent electron transfer kinetic and catalytic effects related to the redox process of the substrate 4-aminophenol. No metal or anti-interference membrane was added. Based on the inhibition of laccase activity, pirimicarb can be determined in the range 9.90 × 10(-7) to 1.15 × 10(-5) mol L(-1) using 4-aminophenol as substrate at the optimum pH of 5.0, with acceptable repeatability and reproducibility (relative standard deviations lower than 5%). The limit of detection obtained was 1.8 × 10(-7) mol L(-1) (0.04 mg kg(-1) on a fresh weight vegetable basis). The high activity and catalytic properties of the laccase-based biosensor are retained during ca. one month. The optimized electroanalytical protocol coupled to the QuEChERS methodology were applied to tomato and lettuce samples spiked at three levels; recoveries ranging from 91.0 ± 0.1% to 101.0 ± 0.3% were attained. No significant effects in the pirimicarb electroanalysis were observed by the presence of pro-vitamin A, vitamins B1 and C, and glucose in the vegetable extracts. The proposed biosensor-based pesticide residue methodology fulfills all requisites to be used in implementation of food safety programs.
Collapse
Affiliation(s)
- Thiago M B F Oliveira
- REQUIMTE, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, Rua Dr. Bernardino de Almeida 431, 4200-072 Porto, Portugal
| | | | | | | | | | | | | |
Collapse
|
38
|
Opportunities and challenges of using ion-selective electrodes in environmental monitoring and wearable sensors. Electrochim Acta 2012. [DOI: 10.1016/j.electacta.2012.04.147] [Citation(s) in RCA: 82] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
39
|
Achievements and future trends in the analysis of emerging organic contaminants in environmental samples by mass spectrometry and bioanalytical techniques. J Chromatogr A 2012; 1259:86-99. [DOI: 10.1016/j.chroma.2012.07.024] [Citation(s) in RCA: 107] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2012] [Revised: 06/10/2012] [Accepted: 07/09/2012] [Indexed: 12/16/2022]
|
40
|
McGrath TF, Elliott CT, Fodey TL. Biosensors for the analysis of microbiological and chemical contaminants in food. Anal Bioanal Chem 2012; 403:75-92. [PMID: 22278073 DOI: 10.1007/s00216-011-5685-9] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2011] [Revised: 11/17/2011] [Accepted: 12/19/2011] [Indexed: 10/14/2022]
Abstract
Increases in food production and the ever-present threat of food contamination from microbiological and chemical sources have led the food industry and regulators to pursue rapid, inexpensive methods of analysis to safeguard the health and safety of the consumer. Although sophisticated techniques such as chromatography and spectrometry provide more accurate and conclusive results, screening tests allow a much higher throughput of samples at a lower cost and with less operator training, so larger numbers of samples can be analysed. Biosensors combine a biological recognition element (enzyme, antibody, receptor) with a transducer to produce a measurable signal proportional to the extent of interaction between the recognition element and the analyte. The different uses of the biosensing instrumentation available today are extremely varied, with food analysis as an emerging and growing application. The advantages offered by biosensors over other screening methods such as radioimmunoassay, enzyme-linked immunosorbent assay, fluorescence immunoassay and luminescence immunoassay, with respect to food analysis, include automation, improved reproducibility, speed of analysis and real-time analysis. This article will provide a brief footing in history before reviewing the latest developments in biosensor applications for analysis of food contaminants (January 2007 to December 2010), focusing on the detection of pathogens, toxins, pesticides and veterinary drug residues by biosensors, with emphasis on articles showing data in food matrices. The main areas of development common to these groups of contaminants include multiplexing, the ability to simultaneously analyse a sample for more than one contaminant and portability. Biosensors currently have an important role in food safety; further advances in the technology, reagents and sample handling will surely reinforce this position.
Collapse
Affiliation(s)
- T F McGrath
- ASSET Technology Centre, Institute of Agri-Food and Land Use, School of Biological Sciences, Queen's University Belfast, Belfast, UK.
| | | | | |
Collapse
|
41
|
Luminescence sensors applied to water analysis of organic pollutants--an update. SENSORS 2011; 11:11081-102. [PMID: 22247654 PMCID: PMC3251971 DOI: 10.3390/s111211081] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2011] [Revised: 11/09/2011] [Accepted: 11/18/2011] [Indexed: 01/08/2023]
Abstract
The development of chemical sensors for environmental analysis based on fluorescence, phosphorescence and chemiluminescence signals continues to be a dynamic topic within the sensor field. This review covers the fundamentals of this type of sensors, and an update on recent works devoted to quantifying organic pollutants in environmental waters, focusing on advances since about 2005. Among the wide variety of these contaminants, special attention has been paid polycyclic aromatic hydrocarbons, pesticides, explosives and emerging organic pollutants. The potential of coupling optical sensors with multivariate calibration methods in order to improve the selectivity is also discussed.
Collapse
|
42
|
Experimental methods and modeling techniques for description of cell population heterogeneity. Biotechnol Adv 2011; 29:575-99. [DOI: 10.1016/j.biotechadv.2011.03.007] [Citation(s) in RCA: 91] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2010] [Revised: 02/04/2011] [Accepted: 03/31/2011] [Indexed: 11/24/2022]
|
43
|
Gredell JA, Frei CS, Cirino PC. Protein and RNA engineering to customize microbial molecular reporting. Biotechnol J 2011; 7:477-99. [PMID: 22031507 DOI: 10.1002/biot.201100266] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2011] [Revised: 07/20/2011] [Accepted: 08/23/2011] [Indexed: 12/19/2022]
Abstract
Nature takes advantage of the malleability of protein and RNA sequence and structure to employ these macromolecules as molecular reporters whose conformation and functional roles depend on the presence of a specific ligand (an "effector" molecule). By following nature's example, ligand-responsive proteins and RNA molecules are now routinely engineered and incorporated into customized molecular reporting systems (biosensors). Microbial small-molecule biosensors and endogenous molecular reporters based on these sensing components find a variety of applications that include high-throughput screening of biosynthesis libraries, environmental monitoring, and novel gene regulation in synthetic biology. Here, we review recent advances in engineering small-molecule recognition by proteins and RNA and in coupling in vivo ligand binding to reporter-gene expression or to allosteric activation of a protein conferring a detectable phenotype. Emphasis is placed on microbial screening systems that serve as molecular reporters and facilitate engineering the ligand-binding component to recognize new molecules.
Collapse
Affiliation(s)
- Joseph A Gredell
- Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX, USA
| | | | | |
Collapse
|
44
|
Dale SEC, Vuorema A, Ashmore EMY, Kasprzyk-Horden B, Sillanpää M, Denuault G, Marken F. Gold-gold junction electrodes:the disconnection method. CHEM REC 2011; 12:143-8. [DOI: 10.1002/tcr.201100008] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2011] [Indexed: 10/17/2022]
|
45
|
Affiliation(s)
- Ana Ballesteros-Gómez
- Department of Analytical Chemistry, Edificio Anexo Marie Curie, Campus de Rabanales, 14071 Córdoba, Spain
| | - Soledad Rubio
- Department of Analytical Chemistry, Edificio Anexo Marie Curie, Campus de Rabanales, 14071 Córdoba, Spain
| |
Collapse
|
46
|
Van Ginkel SW, Hassan SHA, Ok YS, Yang JE, Kim YS, Oh SE. Detecting oxidized contaminants in water using sulfur-oxidizing bacteria. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2011; 45:3739-3745. [PMID: 21417357 DOI: 10.1021/es1036892] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
For the rapid and reliable detection of oxidized contaminants (i.e., nitrite, nitrate, perchlorate, dichromate) in water, a novel toxicity detection methodology based on sulfur-oxidizing bacteria (SOB) has been developed. The methodology exploits the ability of SOB to oxidize elemental sulfur to sulfuric acid in the presence of oxygen. The reaction results in an increase in electrical conductivity (EC) and a decrease in pH. When oxidized contaminants were added to the system, the effluent EC decreased and the pH increased due to the inhibition of the SOB. We found that the system can detect these contaminants in the 5-50 ppb range (in the case of NO(3)(-), 10 ppm was detected), which is lower than many whole-cell biosensors to date. At low pH, the oxidized contaminants are mostly in their acid or nonpolar, protonated form which act as uncouplers and make the SOB biosensor more sensitive than other whole-cell biosensors which operate at higher pH values where the contaminants exist as dissociated anions. The SOB biosensor can detect toxicity on the order of minutes to hours which can serve as an early warning so as to not pollute the environment and affect public health.
Collapse
Affiliation(s)
- Steven W Van Ginkel
- Swette Center for Environmental Biotechnology, Biodesign Institute, Arizona State University , P.O. Box 875701, Tempe, Arizona 85287-5701, United States
| | | | | | | | | | | |
Collapse
|
47
|
Turdean GL. Design and Development of Biosensors for the Detection of Heavy Metal Toxicity. INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY 2011. [DOI: 10.4061/2011/343125] [Citation(s) in RCA: 113] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Many compounds (including heavy metals, HMs) used in different fields of industry and/or agriculture act as inhibitors of enzymes, which, as consequence, are unable to bind the substrate. Even if it is not so sensitive, the method for detecting heavy metal traces using biosensors has a dynamic trend and is largely applied for improving the “life quality”, because of biosensor's sensitivity, selectivity, and simplicity. In the last years, they also become more and more a synergetic combination between biotechnology and microelectronics. Dedicated biosensors were developed for offline and online analysis, and also, their extent and diversity could be called a real “biosensor revolution”. A panel of examples of biosensors: enzyme-, DNA-, imuno-, whole-cell-based biosensors were systematised depending on the reaction type, transduction signal, or analytical performances. The mechanism of enzyme-based biosensor and the kinetic of detection process are described and compared. In this context, is explainable why bioelectronics, nanotechnology, miniaturization, and bioengineering will compete for developing sensitive and selective biosensors able to determine multiple analytes simultaneously and/or integrated in wireless communications systems.
Collapse
Affiliation(s)
- Graziella L. Turdean
- Physical Chemistry Department, Babes-Bolyai, University of Cluj-Napoca, 11 Arany Janos Street, 400028 Cluj-Napoca, Romania
| |
Collapse
|
48
|
Van Dyk JS, Pletschke B. Review on the use of enzymes for the detection of organochlorine, organophosphate and carbamate pesticides in the environment. CHEMOSPHERE 2011; 82:291-307. [PMID: 21055790 DOI: 10.1016/j.chemosphere.2010.10.033] [Citation(s) in RCA: 205] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2010] [Revised: 10/05/2010] [Accepted: 10/11/2010] [Indexed: 05/03/2023]
Abstract
Pesticides are released intentionally into the environment and, through various processes, contaminate the environment. Three of the main classes of pesticides that pose a serious problem are organochlorines, organophosphates and carbamates. While pesticides are associated with many health effects, there is a lack of monitoring data on these contaminants. Traditional chromatographic methods are effective for the analysis of pesticides in the environment, but have limitations and prevent adequate monitoring. Enzymatic methods have been promoted for many years as an alternative method of detection of these pesticides. The main enzymes that have been utilised in this regard have been acetylcholinesterase, butyrylcholinesterase, alkaline phosphatase, organophosphorus hydrolase and tyrosinase. The enzymatic methods are based on the activation or inhibition of the enzyme by a pesticide which is proportional to the concentration of the pesticide. Research on enzymatic methods of detection, as well as some of the problems and challenges associated with these methods, is extensively discussed in this review. These methods can serve as a tool for screening large samples which can be followed up with the more traditional chromatographic methods of analysis.
Collapse
Affiliation(s)
- J Susan Van Dyk
- Department of Biochemistry, Microbiology and Biotechnology, Rhodes University, Grahamstown 6140, South Africa
| | | |
Collapse
|
49
|
Moujahid W, Eichelmann-Daly P, Strutwolf J, Ogurtsov VI, Herzog G, Arrigan DWM. Microelectrochemical Systems on Silicon Chips for the Detection of Pollutants in Seawater. ELECTROANAL 2010. [DOI: 10.1002/elan.201000424] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
50
|
Van Ginkel SW, Hassan SHA, Oh SE. Detecting endocrine disrupting compounds in water using sulfur-oxidizing bacteria. CHEMOSPHERE 2010; 81:294-297. [PMID: 20580056 DOI: 10.1016/j.chemosphere.2010.05.056] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2010] [Revised: 05/25/2010] [Accepted: 05/30/2010] [Indexed: 05/29/2023]
Abstract
For the rapid and reliable detection of endocrine disrupting compounds in water, a novel toxicity detection methodology based on sulfur-oxidizing bacteria (SOB) has been developed. The methodology exploits the ability of SOB to oxidize elemental sulfur to sulfuric acid in the presence of oxygen. The reaction results in an increase in electrical conductivity (EC) and a decrease in pH. When endocrine disrupting compounds were added to the system, the effluent EC decreased and the pH increased due to the inhibition of the SOB. We found that the system can detect these chemicals in the 50-200 ppb range, which is lower than many whole-cell biosensors to date. The SOB biosensor can detect toxicity on the order of min to h which can serve as an early warning so as to not pollute the environment and affect public health.
Collapse
Affiliation(s)
- Steven W Van Ginkel
- Center for Environmental Biotechnology, Biodesign Institute, Arizona State University, P.O. Box 875701, Tempe, AZ 85287-5701, USA.
| | | | | |
Collapse
|