1
|
Qiu Z, Wei C, Kang L, Zhou L, Lai C, Li X, Yan B, Xu J, Wang S, Huang L. Sensitive quantitation of ultra-trace toxic aconitines in complex matrices by perfusion nano-electrospray ionization mass spectrometry combined with gas-liquid microextraction. Talanta 2024; 269:125402. [PMID: 37979510 DOI: 10.1016/j.talanta.2023.125402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2023] [Revised: 11/06/2023] [Accepted: 11/07/2023] [Indexed: 11/20/2023]
Abstract
The accurate analysis of ultra-trace (e.g. <10-4 ng/mL) substances in complex matrices is a burdensome but vital problem in pharmaceutical analysis, with important implications for precise quality control of drugs, discovery of innovative medicines and elucidation of pharmacological mechanisms. Herein, an innovative constant-flow perfusion nano-electrospray ionization (PnESI) technique was developed firstly features significant quantitative advantages in high-sensitivity ambient MS analysis of complex matrix sample. More importantly, double-labeled addition enrichment quantitation strategies of gas-liquid microextraction (GLME) were proposed for the first time, allowing highly selective extraction and enrichment of specific target analytes in a green and ultra-efficient (>1000-fold) manner. Using complex processed Aconitum herbs as example, PnESI-MS directly enabled the qualitative and absolute quantitative analysis of the processed Aconitum extracts and characterized the target toxic diester alkaloids with high sensitivity, high stability, wide linearity range, and strong resistance to matrix interference. Further, GLME device was applied to obtain the highly specific enrichment of the target diester alkaloids more than 1000-fold, and accurate absolute quantitation of trace aconitine, mesaconitine, and hypaconitine in the extracts of Heishunpian, Zhichuanwu and Zhicaowu was accomplished (e.g., 0.098 pg/mL and 0.143 pg/mL), with the quantitation results well below the LODs of aconitines from any analytical instruments available. This study built a systematic strategy for accurate quantitation of ultra-trace substances in complex matrix sample and expected to provide a technological revolution in many fields of pharmaceutical research.
Collapse
Affiliation(s)
- Zidong Qiu
- State Key Laboratory for Quality Ensurance and Sustainable Use of Dao-di Herbs, National Resource Center for Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing, 100700, China.
| | - Chaofa Wei
- State Key Laboratory for Quality Ensurance and Sustainable Use of Dao-di Herbs, National Resource Center for Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Liping Kang
- State Key Laboratory for Quality Ensurance and Sustainable Use of Dao-di Herbs, National Resource Center for Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Li Zhou
- State Key Laboratory for Quality Ensurance and Sustainable Use of Dao-di Herbs, National Resource Center for Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Changjiangsheng Lai
- State Key Laboratory for Quality Ensurance and Sustainable Use of Dao-di Herbs, National Resource Center for Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Xiang Li
- State Key Laboratory for Quality Ensurance and Sustainable Use of Dao-di Herbs, National Resource Center for Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Binbin Yan
- State Key Laboratory for Quality Ensurance and Sustainable Use of Dao-di Herbs, National Resource Center for Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Jiaquan Xu
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, College of Chemistry, Biology and Material Sciences, East China Institute of Technology, Nanchang, 330013, China
| | - Shuanglong Wang
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, College of Chemistry, Biology and Material Sciences, East China Institute of Technology, Nanchang, 330013, China.
| | - Luqi Huang
- State Key Laboratory for Quality Ensurance and Sustainable Use of Dao-di Herbs, National Resource Center for Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing, 100700, China.
| |
Collapse
|
2
|
Dong W, Lin W, Chen X, Lian X, Shen C, Liu M, Lin F, Sun X, Xu Y, Xiong Y, Deng B. Reducing the background interference of liquid–liquid extraction method during Baijiu aroma analysis. Food Chem 2023; 404:134557. [DOI: 10.1016/j.foodchem.2022.134557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2022] [Revised: 09/12/2022] [Accepted: 10/07/2022] [Indexed: 11/22/2022]
|
3
|
Li C, Jiang Y, Chu S, Yin X, Tan S, Huang Z, Dai X, Gong X, Fang X, Tian D. Analysis of low-abundance molecules in complex matrices by quadrupole-linear ion trap mass spectrometry using a simultaneous fragmentation and accumulation strategy. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022; 36:e9276. [PMID: 35189675 DOI: 10.1002/rcm.9276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Revised: 02/16/2022] [Accepted: 02/17/2022] [Indexed: 06/14/2023]
Abstract
RATIONALE Fast and sensitive analysis of low-abundance molecules in complex matrices has always been a challenge in chemical and biological applications. Mass spectrometry (MS) has been widely used in the fields of chemical and biological analysis due to its unparalleled specificity and sensitivity. However, the MS signals consistently deteriorate in the presence of matrices. Demands for more sensitive and efficient methods to analyze those low-abundance molecules in chemical and biological systems are in urgent need. METHODS Based on a home-made quadrupole-linear ion trap (Q-LIT) mass spectrometer, a simultaneous fragmentation and accumulation strategy was developed to improve the sensitivity of the analysis for the low-abundance molecules in complex matrices. Ions were filtered by the quadrupole into the LIT. The precursor ions were fragmented and the product ions were isolated and accumulated in the LIT simultaneously. The fragmentation, isolation and accumulation processes were conducted at the same time. The accumulation time could be controlled to accumulate sufficient product ions. RESULTS With this strategy, the signal intensity of targeted molecules could be increased by 2-8 times and by increasing the accumulation time, this could be further enhanced. Those interferences induced by isomers and matrices can be reduced by using our method. We further applied our method to the quantification and analysis of biological samples. Tryptic digested peptides of myoglobin (Mb) were successfully detected by our method. CONCLUSIONS We have established a new method with great advantages in the detection of molecules in complex matrices. The application of this method promises better results in the bioanalytical area, especially for the analysis of substances in complex matrices in the future.
Collapse
Affiliation(s)
- Chang Li
- College of Instrumentation & Electrical Engineering, Jilin University, Changchun, China
| | - You Jiang
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, China
| | - Shiying Chu
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, China
| | - Xinchi Yin
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, China
| | - Siyuan Tan
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, China
| | - Zejian Huang
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, China
| | - Xinhua Dai
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, China
| | - Xiaoyun Gong
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, China
| | - Xiang Fang
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, China
| | - Di Tian
- College of Instrumentation & Electrical Engineering, Jilin University, Changchun, China
| |
Collapse
|
4
|
Distribution Dynamics of Phthalate Esters in Surface Water and Sediment of the Middle-Lower Hanjiang River, China. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19052702. [PMID: 35270394 PMCID: PMC8910556 DOI: 10.3390/ijerph19052702] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 02/20/2022] [Accepted: 02/22/2022] [Indexed: 12/15/2022]
Abstract
Phthalate esters (PAEs) are endocrine-disrupting chemicals that pose potential risks to human health. Water and sediments are crucial carriers and storage media for the migration and transformation of PAEs. In this study, six congeners of PAEs were measured in water and sediment samples to elucidate their spatial distribution, congener profiles, and ecological risks in the middle-lower Hanjiang River during the wet and dry seasons. The concentration of the Σ6PAEs ranged from 592 to 2.75 × 103 ng/L with an average of 1.47 × 103 ng/L in surface water, while the concentration of the Σ6PAEs ranged from 1.12 × 103 to 6.61 × 103 ng/g with an average of 2.69 × 103 ng/g in sediments. In general, PAE concentrations were ranked as sediment > water, and dry season > wet season. DEHP and DBP were the dominant PAEs in the middle-lower Hanjiang River in surface water and sediments. SPSS analysis showed that dissolved organic carbon (DOC) in surface water was significantly correlated with the concentration of DBP, DEHP, and the ∑6PAEs, while organic matter (OM) was significantly correlated with the concentration of the ∑6PAEs in sediments. The concentrations of PAEs were irregularly distributed and varied significantly in surface water and sediments. Compared with other regions at home and abroad, the pollution levels of surface water and sediments in the middle-lower Hanjiang River were relatively low and not enough to have a negative impact on the local water’s ecological environment. However, the supervision of land-based discharge should still be strengthened.
Collapse
|
5
|
Maciel EVS, Lanças FM. A cartridge-based device for automated analyses of solid matrices by online sample prep-capillary LC-MS/MS. Anal Bioanal Chem 2022; 414:2725-2737. [PMID: 35106613 DOI: 10.1007/s00216-022-03916-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 01/16/2022] [Accepted: 01/19/2022] [Indexed: 11/25/2022]
Abstract
Sample preparation is an essential step focused on eliminating interfering compounds while pre-concentrating the analytes. However, its multiple steps are laborious, time-consuming, and a source of errors. Currently, automated approaches represent a promising alternative to overcome these drawbacks. Similarly, miniaturisation has been considered an ideal strategy for creating greener analytical workflows. The combination of these concepts is currently highly desired by analytical chemists. However, most automated and miniaturised sample preparation techniques are primarily concerned with liquid samples, while solids are frequently overlooked. We present an approach based on a cartridge packed with solids (soil samples) coupled with a capillary LC-MS, combining sample preparation and analytical steps into a unique platform. As a proof-of-concept, nine pesticides used in sugarcane crops were extracted and analysed by our proposed method. For optimisation, a fractional factorial design (25-1) was performed with the following variables: aqueous dilution of the sample (V1), extraction strength (V2), matrix washing time (V3), extraction flow (V4), and analytical flow (V5). After, the most influential ones (V1, V2, and V3) were taken into a central composite design (23) to select their best values. Under optimised conditions, the method reported linear ranges between 10 and 125 ng g-1 with R2 > 0.985. Accuracy and precision were in accordance with the values established by the International Council for Harmonisation (Q2(R1)). Therefore, the proposed approach was effective in extracting and analysing selected pesticides in soil samples. Also, we carried out initial qualitative tests for pesticides in honeybees to see if there is the possibility to apply our method in other solids.
Collapse
Affiliation(s)
- Edvaldo Vasconcelos Soares Maciel
- University of São Paulo, São Carlos, Institute of Chemistry of São Carlos, Av. Trabalhador São-Carlense, 400, São Carlos, SP, Postal Code: 13566590, Brazil
| | - Fernando Mauro Lanças
- University of São Paulo, São Carlos, Institute of Chemistry of São Carlos, Av. Trabalhador São-Carlense, 400, São Carlos, SP, Postal Code: 13566590, Brazil.
| |
Collapse
|
6
|
Wiest L, Giroud B, Assoumani A, Lestremau F, Vulliet E. A multi-family offline SPE LC-MS/MS analytical method for anionic, cationic and non-ionic surfactants quantification in surface water. Talanta 2021; 232:122441. [PMID: 34074426 DOI: 10.1016/j.talanta.2021.122441] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 04/12/2021] [Accepted: 04/17/2021] [Indexed: 01/22/2023]
Abstract
Of the large number of emerging pollutants discharged from wastewaters into surface waters, surfactants are among those with the highest concentrations. However, few monitoring in river waters of these substances have already been performed and only on a few families, mostly anionic. This work aimed to develop a multi-family analytical strategy suitable for the quantification of low concentrations of surfactant in surface waters. Twelve families of surfactants, anionic, cationic and non-ionic were selected. Their quantification by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) and their extraction by SPE were optimized by comparing different retention mechanisms. The best performances were obtained with a C18 grafted silica LC column and a hydrophilic-lipophilic balanced (HLB) polymeric SPE cartridge. The final analytical method was validated and applied for the quantification of surfactants in 36 river water samples. Method limits of quantification (LQ), intra and inter days precision and trueness were evaluated. With LQ between 15 and 485 ng/L, and trueness over 80%, this method was suitable for monitoring surfactants in surface water. Application on French river water samples revealed the presence of anionic, cationic and non-ionic surfactants with median concentrations from 24 ng/L for octylphenol ethoxylates (OPEO), up to 4.6 μg/L regarding linear alkylbenzene sulfonates (LAS).
Collapse
Affiliation(s)
- Laure Wiest
- Univ Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 Rue de la Doua, F-69100, Villeurbanne, France.
| | - Barbara Giroud
- Univ Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 Rue de la Doua, F-69100, Villeurbanne, France
| | - Azziz Assoumani
- INERIS, Unité Méthodes et développements en Analyses pour l'Environnement, F-60550, Verneuil-en-halatte, France
| | - François Lestremau
- INERIS, Unité Méthodes et développements en Analyses pour l'Environnement, F-60550, Verneuil-en-halatte, France
| | - Emmanuelle Vulliet
- Univ Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 Rue de la Doua, F-69100, Villeurbanne, France
| |
Collapse
|
7
|
Jurado-Campos N, Chiluwal U, Eiceman GA. Improved selectivity for the determination of trinitrotoluene through reactive stage tandem ion mobility spectrometry and a quantitative measure of source-based suppression of ionization. Talanta 2021; 226:121944. [PMID: 33676637 DOI: 10.1016/j.talanta.2020.121944] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 11/25/2020] [Accepted: 11/26/2020] [Indexed: 10/22/2022]
Abstract
A tandem ion mobility spectrometer was used to mobility isolate ions at the drift time for trinitrotoluene (TNT) in a first mobility stage, remove an interfering compound by ion decomposition in a middle reactive stage, and mobility characterize the remaining TNT ions in a second mobility stage. This sequential processing of ions provided decisive detection of TNT in the presence of an interfering peak differing from TNT in reduced mobility coefficient (Ko) by only 0.02 cm2/V. Even though ions of TNT (as M - 1)- and the interfering compound were more than 90% convolved, TNT could be selectively detected with more than 95% decomposition of the interferent at 123 Td to an ion now separated by ΔKo of 0.2 cm2/V from TNT. Ions for TNT were not decomposed in these electric fields though transmission efficiency was decreased by 20% through a wire grid assembly (the reactive stage). Although tandem ion mobility spectrometry with a reactive stage improves selectivity of measurement in the drift time dimension, the chemistry of ion formation in the ion source is affected still by ion suppression. Response to 1 ng TNT was decreased as much as 30% from 200 ng of interferent deposited on sample trap.
Collapse
Affiliation(s)
- N Jurado-Campos
- Department of Analytical Chemistry, University of Córdoba, 14071, Córdoba, Spain.
| | - U Chiluwal
- Department of Chemistry and Biochemistry, New Mexico State University, Las Cruces, NM, 88003, United States
| | - G A Eiceman
- Department of Chemistry and Biochemistry, New Mexico State University, Las Cruces, NM, 88003, United States
| |
Collapse
|
8
|
|
9
|
Practical sample pretreatment techniques coupled with capillary electrophoresis for real samples in complex matrices. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2019.115702] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
10
|
Bell M, Blais JM. "-Omics" workflow for paleolimnological and geological archives: A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 672:438-455. [PMID: 30965259 DOI: 10.1016/j.scitotenv.2019.03.477] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2018] [Revised: 03/29/2019] [Accepted: 03/30/2019] [Indexed: 06/09/2023]
Abstract
"-Omics" is a powerful screening method with applications in molecular biology, toxicology, wildlife biology, natural product discovery, and many other fields. Genomics, proteomics, metabolomics, and lipidomics are common examples included under the "-omics" umbrella. This screening method uses combinations of untargeted, semi-targeted, and targeted analyses paired with data mining to facilitate researchers' understanding of the genome, proteins, and small organic molecules in biological systems. Recently, however, the use of "-omics" has expanded into the fields of geology, specifically petrology, and paleolimnology. Specifically, untargeted analyses stand to transform these fields as petroleomics, and sediment-"omics" become more prevalent. "-Omics" facilitates the visualization of small molecule profiles from environmental matrices (i.e. oil and sediment). Small molecule profiles can provide improved understanding of small molecules distributions throughout the environment, and how those compositions can change depending on conditions (i.e. climate change, weathering, etc.). "-Omics" also facilities discovery of next-generation biomarkers that can be used for oil source identification and as proxies for reconstructing past environmental changes. Untargeted analyses paired with data mining and multivariate statistical analyses represents a powerful suite of tools for hypothesis generation, and new method development for environmental reconstructions. Here we present an introduction to "-omics" methodology, technical terms, and examples of applications to paleolimnology and petrology. The purpose of this review is to highlight the important considerations at each step in the "-omics" workflow to produce high quality and statistically powerful data for petrological and paleolimnological applications.
Collapse
Affiliation(s)
- Madison Bell
- Laboratory for the Analysis of Natural and Synthetic Environmental Toxicants, Department of Biology, University of Ottawa, Ottawa, ON K1N 6N5, Canada
| | - Jules M Blais
- Laboratory for the Analysis of Natural and Synthetic Environmental Toxicants, Department of Biology, University of Ottawa, Ottawa, ON K1N 6N5, Canada.
| |
Collapse
|
11
|
Jamrógiewicz M, Pieńkowska K. Recent breakthroughs in the stability testing of pharmaceutical compounds. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2018.12.007] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|