1
|
Yang M, Wang L, Xie C, Lu H, Wang J, Li Y, Li H, Yang J, Zhang T, Liu S. A disposable ultrasensitive immunosensor based on MXene/NH 2-CNT modified screen-printed electrode for the detection of ovarian cancer antigen CA125. Talanta 2025; 281:126893. [PMID: 39288586 DOI: 10.1016/j.talanta.2024.126893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2024] [Revised: 08/24/2024] [Accepted: 09/13/2024] [Indexed: 09/19/2024]
Abstract
Cancer antigen 125 (CA125) is the gold standard biomarker for clinical diagnosis of ovarian cancer, with a threshold value of 35 U/mL in serum. In this paper, a disposable ultrasensitive immunosensor based on Ti3C2Tx-MXene/amino-functionalized carbon nanotube (NH2-CNT) modified screen-printed carbon electrode (SPCE) was constructed for the detection of the ovarian cancer antigen CA125. By optimizing the mass ratio of Ti3C2Tx to NH2-CNT, Ti3C2Tx/NH2-CNT composite with excellent electrochemical properties was prepared, which is beneficial for amplifying the initial electrochemical signal. The positively charged NH2-CNT effectively alleviated the stacking problem of Ti3C2Tx, and its amino group also facilitated the covalent immobilization of the capture antibody. Meanwhile, chitosan (CS) with excellent film-forming ability was also used to successfully enhance the adsorption of electrode material, thus improving the stability of the sensor. In addition, CS could further enhance the current signal. The prepared immunosensor exhibited excellent performance in CA125 detection with a wide linear range from 1 mU/mL to 500 U/mL, and good selectivity, reproducibility and lomg-term stability. Furthermore, the immunosensor showed satisfactory results for the detection of CA125 in clinical serum samples, which is promising for the clinical screening, early diagnosis and prognostic examination of ovarian cancer.
Collapse
Affiliation(s)
- Meiqing Yang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, PR China; Zoology Key Laboratory of Hunan Higher Education, College of Life and Environmental Science, Hunan University of Arts and Science, Changde, 415000, PR China
| | - Lu Wang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, PR China
| | - Congkai Xie
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, PR China
| | - Haozi Lu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, PR China
| | - Junhua Wang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, PR China
| | - Ye Li
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, PR China
| | - Huimin Li
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, PR China
| | - Jifei Yang
- Changsha Sunjeen Electronic Technology Co., Ltd., Changsha, 410205, PR China
| | - Tingting Zhang
- Department of Obstetrics and Gynecology, The Second Xiangya Hospital, Central South University, Changsha, 410000, PR China.
| | - Song Liu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, PR China.
| |
Collapse
|
2
|
Geng L, Huang J, Fang M, Wang H, Liu J, Wang G, Hu M, Sun J, Guo Y, Sun X. Recent progress of the research of metal-organic frameworks-molecularly imprinted polymers (MOFs-MIPs) in food safety detection field. Food Chem 2024; 458:140330. [PMID: 38970953 DOI: 10.1016/j.foodchem.2024.140330] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Revised: 05/23/2024] [Accepted: 07/02/2024] [Indexed: 07/08/2024]
Abstract
Food safety is an important cornerstone of protecting human health and life. Therefore, it is of great significance to detect possible pollutants in food sensitively and efficiently. Molecularly imprinted polymers (MIPs) and metal-organic frameworks (MOFs) have been widely used in the adsorption and detection of food pollutants. However, traditional MIPs have problems such as uneven loading of the imprinted cavity and slow mass transfer efficiency. While the adsorption of MOFs has low specificity and cannot accurately identify target molecules. Therefore, some researchers have taken advantage of the high specific recognition abilities of MIPs and the large specific surface areas, high porosity and easy functionalization of MOFs to combine MOFs with MIPs, and have achieved a series of important results in the field of food safety detection. This paper reviews the research progress of the application of MOFs-MIPs in the field of food safety detection from 2019 to 2024. It furnishes researchers interested in this domain with a rapid and comprehensive grasp of the latest research status, it also offers them a chance to anticipate future development trends, thereby supporting the continuous advances of MOFs-MIPs in food safety detection.
Collapse
Affiliation(s)
- Lingjun Geng
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Jingcheng Huang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Mingxuan Fang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Haifang Wang
- Dongzhimen Hospital, Beijing University of Chinese Medicine, Beijing 100700, China
| | - Jingjing Liu
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Guangxian Wang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Mengjiao Hu
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Jiashuai Sun
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Yemin Guo
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China.
| | - Xia Sun
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China.
| |
Collapse
|
3
|
Han F, Cheng C, Zhao J, Wang H, Zhao G, Zhang Y, Zhang N, Wang Y, Zhang J, Wei Q. Single-atom nanozymes: Emerging talent for sensitive detection of heavy metals. Colloids Surf B Biointerfaces 2024; 242:114093. [PMID: 39029248 DOI: 10.1016/j.colsurfb.2024.114093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Revised: 07/10/2024] [Accepted: 07/11/2024] [Indexed: 07/21/2024]
Abstract
In recent years, the increasingly severe pollution of heavy metals has posed a significant threat to the environment and human safety. Heavy metal ions are highly non-biodegradable, with a tendency to accumulate through biomagnification. Consequently, accurate detection of heavy metal ions is of paramount importance. As a new type of synthetic nanomaterials, single-atom nanozymes (SANs) boast exceptional enzyme-like properties, setting them apart from natural enzymes. This unique feature affords SANs with a multitude of advantages such as dispersed active sites, low cost and variety of synthetic methods over natural enzymes, making them an enticing prospect for various applications in industrial, medical and biological fields. In this paper, we systematically summarize the synthetic methods and catalytic mechanisms of SANs. We also briefly review the analytical methods for heavy metal ions and present an overall overview of the research progress in recent years on the application of SANs in the detection of environmental heavy metal ions. Eventually, we propose the existing challenges and provide a vision for the future.
Collapse
Affiliation(s)
- Fangqin Han
- Shandong Provincial Key Laboratory of Molecular Engineering, School of Chemistry and Chemical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, People's Republic of China
| | - Chunfang Cheng
- Shandong Provincial Key Laboratory of Molecular Engineering, School of Chemistry and Chemical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, People's Republic of China
| | - Jingyu Zhao
- Shandong Provincial Key Laboratory of Molecular Engineering, School of Chemistry and Chemical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, People's Republic of China
| | - Huixin Wang
- Shandong Provincial Key Laboratory of Molecular Engineering, School of Chemistry and Chemical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, People's Republic of China
| | - Guanhui Zhao
- College of Chemistry and Chemical Engineering, Qilu Normal University, Jinan 250200, People's Republic of China.
| | - Yong Zhang
- Provincial Key Laboratory of Rural Energy Engineering in Yunnan, School of Energy and Environment Science, Yunnan Normal University, Kunming 650500, People's Republic of China
| | - Nuo Zhang
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, People's Republic of China
| | - Yaoguang Wang
- Shandong Provincial Key Laboratory of Molecular Engineering, School of Chemistry and Chemical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, People's Republic of China.
| | - Jie Zhang
- Shandong Provincial Key Laboratory of Molecular Engineering, School of Chemistry and Chemical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, People's Republic of China.
| | - Qin Wei
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, People's Republic of China
| |
Collapse
|
4
|
Paramasivam G, Palem VV, Meenakshy S, Suresh LK, Gangopadhyay M, Antherjanam S, Sundramoorthy AK. Advances on carbon nanomaterials and their applications in medical diagnosis and drug delivery. Colloids Surf B Biointerfaces 2024; 241:114032. [PMID: 38905812 DOI: 10.1016/j.colsurfb.2024.114032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 05/23/2024] [Accepted: 06/09/2024] [Indexed: 06/23/2024]
Abstract
Carbon nanomaterials are indispensable due to their unique properties of high electrical conductivity, mechanical strength and thermal stability, which makes them important nanomaterials in biomedical applications and waste management. Limitations of conventional nanomaterials, such as limited surface area, difficulty in fine tuning electrical or thermal properties and poor dispersibility, calls for the development of advanced nanomaterials to overcome such limitations. Commonly, carbon nanomaterials were synthesized by chemical vapor deposition (CVD), laser ablation or arc discharge methods. The advancement in these techniques yielded monodispersed carbon nanotubes (CNTs) and allows p-type and n-type doping to enhance its electrical and catalytic activities. The functionalized CNTs showed exceptional mechanical, electrical and thermal conductivity (3500-5000 W/mK) properties. On the other hand, carbon quantum dots (CQDs) exhibit strong photoluminescence properties with high quantum yield. Carbon nanohorns are another fascinating type of nanomaterial that exhibit a unique structure with high surface area and excellent adsorption properties. These carbon nanomaterials could improve waste management by adsorbing pollutants from water and soil, enabling precise environmental monitoring, while enhancing wastewater treatment and drug delivery systems. Herein, we have discussed the potentials of all these carbon nanomaterials in the context of innovative waste management solutions, fostering cleaner environments and healthier ecosystems for diverse biomedical applications such as biosensing, drug delivery, and environmental monitoring.
Collapse
Affiliation(s)
- Gokul Paramasivam
- Department of Biotechnology, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu 602105, India.
| | - Vishnu Vardhan Palem
- Department of Biomedical Engineering, Sri Ramakrishna Engineering College, Coimbatore, Tamil Nadu, 641022 India
| | - Simi Meenakshy
- Department of Chemistry, Amrita Vishwa Vidhyapeetham, Amritapuri, Kollam, Kerala 690525, India
| | - Lakshmi Krishnaa Suresh
- Department of Chemistry, Amrita Vishwa Vidhyapeetham, Amritapuri, Kollam, Kerala 690525, India
| | - Moumita Gangopadhyay
- Department of Chemistry, Amrita Vishwa Vidhyapeetham, Amritapuri, Kollam, Kerala 690525, India
| | - Santhy Antherjanam
- Department of Chemistry, Amrita Vishwa Vidhyapeetham, Amritapuri, Kollam, Kerala 690525, India
| | - Ashok K Sundramoorthy
- Centre for Nano-Biosensors, Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, No.162, Poonamallee High Road, Velappanchavadi, Chennai, Tamil Nadu 600077, India.
| |
Collapse
|
5
|
Zhang L, Xiao J, Xu X, Li K, Li D, Li J. Functionalized Chiral Materials for Use in Chiral Sensors. Crit Rev Anal Chem 2024:1-20. [PMID: 39012839 DOI: 10.1080/10408347.2024.2376233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/18/2024]
Abstract
Chirality represents a fundamental attribute within living systems and is a pervasive phenomenon in the natural world. The identification and analysis of chiral materials within natural environments and biological systems hold paramount importance in clinical, chemical, and biological sciences. Within chiral analysis, there is a burgeoning focus on developing chiral sensors exhibiting exceptional selectivity, sensitivity, and stability, marking it as a forefront area of research. In the past decade (2013-2023), approximately 1990 papers concerning the application of various chiral materials in chiral sensors have been published. Biological materials and nanomaterials have important applications in the development of chiral sensors, which accounting for 26.67% and 45.24% of the material-related applications in these sensors, respectively; moreover, the development of chiral nanomaterials is closely related to the development of portable and stable chiral sensors. Natural chiral materials, utilized as selective recognition units, are combined with carriers characterized by good physical and chemical properties through functionalization to form various functional chiral materials, which improve the recognition efficiency of chiral sensors. In this article, from the perspective of biological materials, polymer materials, nanomaterials, and other functional chiral materials, the applications of chiral sensors are summarized and the research prospects of chiral sensors are discussed.
Collapse
Affiliation(s)
- Lianming Zhang
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, China
| | - Jiaxi Xiao
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, China
| | - Xuemei Xu
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, China
| | - Kaiting Li
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, China
| | - Dan Li
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, China
| | - Jianping Li
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, China
| |
Collapse
|
6
|
Luis-Sunga M, Carinelli S, García G, González-Mora JL, Salazar-Carballo PA. Electrochemical Detection of Bisphenol A Based on Gold Nanoparticles/Multi-Walled Carbon Nanotubes: Applications on Glassy Carbon and Screen Printed Electrodes. SENSORS (BASEL, SWITZERLAND) 2024; 24:2570. [PMID: 38676187 PMCID: PMC11054518 DOI: 10.3390/s24082570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 04/12/2024] [Accepted: 04/13/2024] [Indexed: 04/28/2024]
Abstract
Bisphenol A (BPA) has been classified as an endocrine-disrupting substance that may cause adverse effects on human health and the environment. The development of simple and sensitive electrochemical biosensors is crucial for the rapid and effective quantitative determination of BPA. This work presents a study on electrochemical sensors utilizing gold nanoparticle-modified multi-walled carbon nanotubes (CNT/AuNPs). Glassy carbon electrodes (GCEs) and screen-printed electrodes (SPEs) were conveniently modified and used for BPA detection. AuNPs were electrodeposited onto the CNT-modified electrodes using the galvanostatic method. The electrodes were properly modified and characterized by using Raman spectroscopy, cyclic voltammetry (CV), and electrochemical impedance analysis (EIS). The electrochemical response of the sensors was studied using differential pulse voltammetry (DPV) and constant potential amperometry (CPA) for modified GCE and SPE electrodes, respectively, and the main analytical parameters were studied and optimized. Problems encountered with the use of GCEs, such as sensor degradation and high limit of detection (LOD), were overcome by using modified SPEs and a flow injection device for the measurements. Under this approach, an LOD as low as 5 nM (S/N = 3) was achieved and presented a linear range up to 20 μM. Finally, our investigation addressed interference, reproducibility, and reusability aspects, successfully identifying BPA in both spiked and authentic samples, including commercial and tap waters. These findings underscore the practical applicability of our method for accurate BPA detection in real-world scenarios. Notably, the integration of SPEs and a flow injection device facilitated simplified automation, offering an exceptionally efficient and reliable solution for precise BPA detection in water analysis laboratories.
Collapse
Affiliation(s)
- Maximina Luis-Sunga
- Laboratory of Sensors, Biosensors and Advanced Materials, Faculty of Health Sciences, Universidad de la Laguna, Campus de Ofra s/n, 38071 La Laguna, Spain; (M.L.-S.); (J.L.G.-M.); (P.A.S.-C.)
- Departamento de Química, Instituto Universitario de Materiales y Nanotecnología, Universidad de la Laguna, P.O. Box 456, 38200 La Laguna, Spain;
| | - Soledad Carinelli
- Laboratory of Sensors, Biosensors and Advanced Materials, Faculty of Health Sciences, Universidad de la Laguna, Campus de Ofra s/n, 38071 La Laguna, Spain; (M.L.-S.); (J.L.G.-M.); (P.A.S.-C.)
- Departamento de Ciencias Médicas Básicas and Instituto de Tecnologías Biomédicas, Universidad de La Laguna, 38200 La Laguna, Spain
| | - Gonzalo García
- Departamento de Química, Instituto Universitario de Materiales y Nanotecnología, Universidad de la Laguna, P.O. Box 456, 38200 La Laguna, Spain;
| | - José Luis González-Mora
- Laboratory of Sensors, Biosensors and Advanced Materials, Faculty of Health Sciences, Universidad de la Laguna, Campus de Ofra s/n, 38071 La Laguna, Spain; (M.L.-S.); (J.L.G.-M.); (P.A.S.-C.)
- Departamento de Ciencias Médicas Básicas and Instituto de Tecnologías Biomédicas, Universidad de La Laguna, 38200 La Laguna, Spain
- Instituto Universitario de Neurociencia, Universidad de la Laguna, 38071 Santa Cruz de Tenerife, Spain
| | - Pedro A. Salazar-Carballo
- Laboratory of Sensors, Biosensors and Advanced Materials, Faculty of Health Sciences, Universidad de la Laguna, Campus de Ofra s/n, 38071 La Laguna, Spain; (M.L.-S.); (J.L.G.-M.); (P.A.S.-C.)
| |
Collapse
|
7
|
Yao S, Zhang C, Ping J, Ying Y. Recent advances in hydrogel microneedle-based biofluid extraction and detection in food and agriculture. Biosens Bioelectron 2024; 250:116066. [PMID: 38310731 DOI: 10.1016/j.bios.2024.116066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2023] [Revised: 12/21/2023] [Accepted: 01/22/2024] [Indexed: 02/06/2024]
Abstract
Microneedle (MN) technology has been extensively studied for its advantages of minimal invasiveness and user-friendliness. Notably, hydrogel microneedles (HMNs) have garnered considerable attention for biofluid extraction due to its high swelling properties and biocompatibility. This review provides a comprehensive overview of definition, materials, and fabrication methods associated with HMNs. The extraction mechanisms and optimization strategies for enhancing extraction efficiency are summarized. Moreover, particular emphasis is placed on HMN-based biofluid extraction and detection in the domains of food and agriculture, encompassing the detection of small molecules, nucleic acids, and other relevant analytes. Finally, current challenges and possible solutions associated with HMN-based biofluid extraction are discussed.
Collapse
Affiliation(s)
- Shiyun Yao
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, PR China
| | - Chi Zhang
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, PR China
| | - Jianfeng Ping
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, PR China; ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 311200, PR China
| | - Yibin Ying
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, PR China; ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 311200, PR China.
| |
Collapse
|
8
|
Sharma P, Naithani S, Yadav V, Sangeeta, Guchhait B, Kumar S, Goswami T. Indium nanocubes based recyclable fluorescent chemosensor for sustainable environmental monitoring: pH-induced fluorescence transition and selective detection of Pd(II) ions. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 920:171043. [PMID: 38369158 DOI: 10.1016/j.scitotenv.2024.171043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/24/2023] [Revised: 02/06/2024] [Accepted: 02/15/2024] [Indexed: 02/20/2024]
Abstract
Rapid modern industrialization and urbanization have escalated heavy metal pollution, with palladium (Pd2+) raising significant concerns due to its extensive usage in catalysis, hydrogen storage, and electronics, thereby imposing substantial risks on the environment and human health. In this study, we report a highly fluorescent indium nanocubes based chemosensor (InNCs) functionalized with perylene tetracarboxylic acid (PTCA) and 4-(pyridyl)ethenyl benzene (PEB). The InNCs exhibited emission maximum at 415 nm (λex ∼ 350 nm) with robust chemical and photo-stability, and acted as a fluorogenic probe for selective recognition of Pd2+ in aqueous medium. The fluorescence sensing properties of InNCs were thoroughly assessed via different techniques including steady-state absorption, emission and time-resolved emission spectroscopic methods. Among the various competitive analytes, only Pd2+ could induce a significant fluorescence quenching in the probe. This "turn-off" fluorescence sensing demonstrated a remarkably low LoD of ∼65 nM. Notably, with the addition of EDTA, the probe displayed good recyclability upto 4 cycles. The sensory probe was successfully employed as a reusable platform to estimate Pd(II) in different real water and soil samples with considerable accuracy (∼ 5-10 % error). Moreover, the probe exhibited a pH-induced fluorescence transition, indicating its potential to be applied as a pH sensor. The Pd(II) binding and pH-sensing mechanisms have also been elucidated through density functional theory (DFT) calculations.
Collapse
Affiliation(s)
- Pooja Sharma
- Department of Chemistry, Applied Sciences Cluster, University of Petroleum & Energy Studies (UPES), Energy Acres Building, Dehradun 248007, Uttarakhand, India
| | - Sudhanshu Naithani
- Department of Chemistry, Applied Sciences Cluster, University of Petroleum & Energy Studies (UPES), Energy Acres Building, Dehradun 248007, Uttarakhand, India
| | - Vikas Yadav
- Nanoscopic Imaging and Sensing Lab, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| | - Sangeeta
- Department of Chemistry, School of Natural Sciences, Shiv Nadar Institution of Eminence, Delhi-NCR, Uttar Pradesh 201314, India
| | - Biswajit Guchhait
- Department of Chemistry, School of Natural Sciences, Shiv Nadar Institution of Eminence, Delhi-NCR, Uttar Pradesh 201314, India
| | - Sushil Kumar
- Department of Chemistry, Applied Sciences Cluster, University of Petroleum & Energy Studies (UPES), Energy Acres Building, Dehradun 248007, Uttarakhand, India.
| | - Tapas Goswami
- Department of Chemistry, Applied Sciences Cluster, University of Petroleum & Energy Studies (UPES), Energy Acres Building, Dehradun 248007, Uttarakhand, India.
| |
Collapse
|
9
|
Darwish IA, Suzuki K, Ogawa H, Wang Z. A prototype of ultrasensitive time-resolved fluoroimmunoassay for the quantitation of lead in plasma using a fluorescence-enhanced europium chelate label for the detection system. RSC Adv 2024; 14:8671-8683. [PMID: 38495999 PMCID: PMC10938379 DOI: 10.1039/d3ra07673c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 03/11/2024] [Indexed: 03/19/2024] Open
Abstract
This study describes the prototype of a novel ultra-sensitive time-resolved fluoroimmunoassay (TRFIA) for the quantification of lead (Pb) in plasma. The assay procedures were conducted in 96-microwell plates and involved the competitive binding format. The assay used a mouse monoclonal antibody, designated as 2C33, that specifically recognized the diethylenetriamine pentaacetic acid chelate of Pb (Pb-DTPA) but did not recognize Pb-free DTPA chelator. The antigen used for coating onto the inner surfaces of assay plate microwells was Pb-DTPA conjugated with bovine serum albumin protein (Pb-DTPA-BSA). The competitive binding reaction occurred between Pb-DTPA chelates, formed in the sample solutions by treating the samples with an excess DTPA, and the coated Pb-DTPA-BSA for a limited quantity of 2C33 antibody binding sites. The antigen-antibody complex formed in the plate wells was quantified by a europium-DTPA-labeled secondary antibody and a fluorescence enhancement solution. The conditions of the assay were refined, and its optimum procedures were established. The TRFIA was validated following the immunoassay validation guidelines, and all of the validation criteria were acceptable. The working range of the assay was 20-300 pg mL-1 and its limit of quantitation was 20 pg mL-1. Metals that are commonly encountered in blood plasma did not interfere with Pb in the analysis by the proposed TRFIA. The assay was applied to the quantitation of Pb in plasma samples with satisfactory accuracy and precision. The results were compared favorably with those obtained by atomic emission spectroscopy. In conclusion, the present study represents the first TRFIA for the quantitation of Pb in plasma. The assay is superior to the existing atomic spectrometric methods and other immunoassays for Pb in terms of sensitivity, convenience, and analysis throughputs. The proposed TRFIA is anticipated to effectively contribute to assessing Pb concentrations and controlling the exposure of humans to its potential toxicity.
Collapse
Affiliation(s)
- Ibrahim A Darwish
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University PO Box 2457 Riyadh 11451 Saudi Arabia +966-114676220 +966-114677348
| | - Kenzi Suzuki
- Faculty of Pharmaceutical Sciences, Setsunan University Nagao-toge-machi Hirakata 573-01 Japan
| | - Hiroshi Ogawa
- Core Research for Evolutional Sciences and Technology, Japan Science and Technology Tokyo 113-0033 Japan
| | - Zongzhi Wang
- State Key Laboratory of Freshwater Ecology and Biotechnology, Institute of Hydrobiology, Chinese Academy of Sciences Wuhan China
| |
Collapse
|
10
|
Wang X, Xu M, Kuang Y, Liu X, Yuan J. A novel ratiometric electrochemical aptasensor based on M-shaped functional DNA complexes for simultaneous detection of trace lead and mercury ions in series aquatic edible vegetables. JOURNAL OF HAZARDOUS MATERIALS 2024; 465:133169. [PMID: 38070266 DOI: 10.1016/j.jhazmat.2023.133169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 11/22/2023] [Accepted: 12/01/2023] [Indexed: 02/08/2024]
Abstract
Simultaneous quantification of multiple heavy metal ions (HMIs) is essential due to enhanced toxicity induced by synergistic effects. The currently available detection methods suffer from drawbacks such as costly devices, poor anti-interference, and specificity. In this work, a ratiometric electrochemical aptasensor for simultaneous detection of trace lead (Pb2+) and mercury ions (Hg2+) was developed. Here, a metal-organic framework, UiO-66-CNTs, with inherent and stable electrochemical signal was used for loading complementary strands (CSs) and internal reference. Guanine-rich and thymine-rich oligonucleotides, labelled with carbon dots (CDs), acted as aptamers (Apts) and hybridized with CSs to form M-shaped DNA complexes. Pb2+ and Hg2+ could be recognized and captured by Apts to form Pb2+-G-quadruplex and T-Hg2+-T complexes, leading to the destruction of M-shaped DNA complexes and changes in CDs' signal. The current ratios, ICDs/IUiO-66-CNTs, were applied to quantify Pb2+ and Hg2+. Benefiting from the anti-interference ability of the ratiometric strategy and the specificity of Apts, the proposed method enabled detection Pb2+ and Hg2+ through simple instrumentation, with detection limits of 2.0 ng mL-1 and 0.5 ng mL-1. Moreover, it was applied to assess Pb2+ and Hg2+ contamination in series of aquatic edible vegetables. The experimental results were consistent with inductively coupled plasma-mass spectrometry (ICP-MS), demonstrating its potential in practical applications.
Collapse
Affiliation(s)
- Xiaoying Wang
- Key Laboratory of the Environmental Medicine and Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China.
| | - Mingming Xu
- Key Laboratory of the Environmental Medicine and Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Yijing Kuang
- Key Laboratory of the Environmental Medicine and Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Xiangping Liu
- Nanjing Municipal Center for Disease Control and Prevention, Nanjing 210003, China
| | - Jinhua Yuan
- Nanjing Municipal Center for Disease Control and Prevention, Nanjing 210003, China
| |
Collapse
|
11
|
Hu M, Yue F, Dong J, Tao C, Bai M, Liu M, Zhai S, Chen S, Liu W, Qi G, Vrublevsky I, Sun X, Guo Y. Screening of broad-spectrum aptamer and development of electrochemical aptasensor for simultaneous detection of penicillin antibiotics in milk. Talanta 2024; 269:125508. [PMID: 38070284 DOI: 10.1016/j.talanta.2023.125508] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 11/29/2023] [Accepted: 11/30/2023] [Indexed: 01/05/2024]
Abstract
Penicillin antibiotics (PENs) play an important role in killing pathogenic bacteria. However, the residues of various penicillin antibiotics in milk gradually accumulate in the human body with the increase of milk intake, which causes direct harm to the human body. Aptamers can be used as recognition element of sensors. It is great significance to use broad-spectrum aptamers for simultaneous detection of PENs. In this study, we reported the screening and identification of DNA aptamers for PENs. The aptamers were screened by graphene oxide-systematic evolution of ligands by exponential enrichment (GO-SELEX). The broad-spectrum aptamers with high affinity and specificity were successfully obtained after 13 rounds of screening. The affinity and specificity of candidate aptamers were analyzed by a GO fluorescence competition method. Further sequence analysis revealed that a truncated 47 nt aptamer (P-11-1) had a higher affinity than the original 79 nt aptamer. The truncated aptamer P-11-1 was used as a recognition element, and an electrochemical aptasensor was prepared using gold nanoparticles (AuNPs) combined with ferroferric oxide-multi walled carbon nanotube (Fe3O4-MWCNTs) complex. The results showed that the developed aptasensor achieved the simultaneous detection of PENs in milk samples across a concentration range of 2 nM-10,000 nM, achieving a limit of detection of 0.667 nM. This methodology provided a simple and sensitive new thinking for antibiotic multi-residue detection.
Collapse
Affiliation(s)
- Mengjiao Hu
- College of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Fengling Yue
- College of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Jiwei Dong
- College of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Chong Tao
- College of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Mengyuan Bai
- College of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Mengyue Liu
- College of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Shengxi Zhai
- College of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Shihao Chen
- College of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Wenzheng Liu
- College of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Guangyu Qi
- College of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Igor Vrublevsky
- Department of Information Security, Belarusian State University of Informatics and Radioelectronics, Minsk 220013, Belarus
| | - Xia Sun
- College of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China.
| | - Yemin Guo
- College of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China.
| |
Collapse
|
12
|
Wang J, Zhang L, Yan G, Cheng L, Zhang F, Wu J, Lei Y, An Q, Qi H, Zhang C, Gao Q. Modified exfoliated graphene functionalized with carboxylic acid-group and thionine on a screen-printed carbon electrode as a platform for an electrochemical enzyme immunosensor. Mikrochim Acta 2024; 191:143. [PMID: 38368295 DOI: 10.1007/s00604-024-06212-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 01/11/2024] [Indexed: 02/19/2024]
Abstract
An enzyme immunoassay was developed based on the coulometric measurement of immunoglobulin M (IgM) against Hantaan viruses (HTNV) by using virus-like particles (VLPs) as recognition molecules. The surface functionalization of screen-printed carbon electrodes (SPCEs) was achieved through paste-exfoliated graphene that was modified with a COOH group and a thionine mediator through supramolecular-covalent scaffolds, on SPCEs by using the binder contained in the ink. After the covalent immobilization of the antibody, the sensor was used for the sandwich enzyme immunoassay of IgM against HTNV. By using HTNV VLPs as the second recognization molecules, the resulting sensor efficiently monitored the reaction of IgM against HTNV and anti-IgM antibody with high specificity. By attaching HTNV nucleocapsid protein antibody conjugate with horseradish peroxidase (HRP) onto VLPs, the signal response of the assay was derived from the coulometric measurement of H2O2 reduction mediated by thionine on the electrode surface after the application of a potential (- 0.2 V vs. Ag/AgCl). The ratio of charges measured before or after H2O2 addition was used to quantify IgM because these charges could be used as background charges or total charges, respectively. The ratio exhibited good agreement with IgM concentration within a range 0.1 to 1000 pg mL-1, and a detection limit of 0.06 pg mL-1 was obtained. The assay demonstrated high sensitivity and specificity toward HTNV-specific IgM in serum.
Collapse
Affiliation(s)
- Jing Wang
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, China
| | - Liang Zhang
- Department of Microbiology, Faculty of Preclinical Medicine, Air Force Medical University, Xi'an, 710032, Shaanxi, China
| | - Guanrong Yan
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, China
| | - Linfeng Cheng
- Department of Microbiology, Faculty of Preclinical Medicine, Air Force Medical University, Xi'an, 710032, Shaanxi, China
| | - Fanglin Zhang
- Department of Microbiology, Faculty of Preclinical Medicine, Air Force Medical University, Xi'an, 710032, Shaanxi, China.
| | - Jialin Wu
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, China
| | - Yingfeng Lei
- Department of Microbiology, Faculty of Preclinical Medicine, Air Force Medical University, Xi'an, 710032, Shaanxi, China
| | - Qunxing An
- Department of Transfusion Medicine, The First Affiliated Hospital of Air Force Medical University, Xi'an, 710032, Shaanxi, China.
| | - Honglan Qi
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, China
| | - Chengxiao Zhang
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, China
| | - Qiang Gao
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, China.
| |
Collapse
|
13
|
Li YY, Li KY, Chen SH, Ma N, Song ZY, Yang M, Wang J, Liu WQ. Phosphorus-doped synergy of phase change in heterogeneous catalysts of NiS-NiS 2 for efficient electrocatalysis of Pb(II). Anal Chim Acta 2024; 1288:342149. [PMID: 38220283 DOI: 10.1016/j.aca.2023.342149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 11/16/2023] [Accepted: 12/15/2023] [Indexed: 01/16/2024]
Abstract
A fundamental understanding of the electroanalytical activity of transition metal sulfide electrocatalysts, especially the origin of the electrocatalytic reactivity on the surface sites of heterostructures with multiple crystalline phases, is essential for the design of low-cost and highly efficient nonprecious metal electrocatalysts for further scientific and technological achievements. Herein, we injected P into NiS and occupied the S sites through a doping strategy. The redistributed electronic structure induced the construction of heterostructures, which significantly improved the structure and chemical state of electrochemically inert NiS. The phase-change mechanism between NiS and NiS2 synergistically catalyzes Pb(II), while the P and S sites jointly lose electrons. Moreover, the constructed heterojunction sensor shows the a sensitivity of 83.43 μA μM-1 to Pb(II) with a theoretical limit of detection of 48 nM, as well as excellent stability, reproducibility, and anti-interference ability. The accurate detection in real water further reveals the potential of this sensor for practical applications. This study provides a guiding strategy for improving electrochemically inert materials to design highly active electrocatalytic interfaces, which has important implications for the development of highly efficient electrode-sensitive materials similar to precious metals to achieve accurate electrical analysis.
Collapse
Affiliation(s)
- Yong-Yu Li
- School of Environmental Science and Engineering, Tianjin University, Tianjin, 300350, PR China; Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences, Hefei, 230031, PR China
| | - Kai-Yuan Li
- Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences, Hefei, 230031, PR China; College of Mechanical and Automotive Engineering, Anhui Polytechnic University, Wuhu, 241000, PR China
| | - Shi-Hua Chen
- Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences, Hefei, 230031, PR China
| | - Na Ma
- Institute of Environment, Hefei Comprehensive National Science Center, Hefei, 230088, PR China
| | - Zong-Yin Song
- Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences, Hefei, 230031, PR China.
| | - Meng Yang
- Institute of Environment, Hefei Comprehensive National Science Center, Hefei, 230088, PR China; Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences, Hefei, 230031, PR China.
| | - Jie Wang
- Institutes of Physical Science and Information Technology, Anhui University, Hefei, 230601, PR China; Institute of Environment, Hefei Comprehensive National Science Center, Hefei, 230088, PR China.
| | - Wen-Qing Liu
- School of Environmental Science and Engineering, Tianjin University, Tianjin, 300350, PR China; Institutes of Physical Science and Information Technology, Anhui University, Hefei, 230601, PR China; Institute of Environment, Hefei Comprehensive National Science Center, Hefei, 230088, PR China.
| |
Collapse
|
14
|
Chen J, Chen M, Tong H, Wu F, Liu Y, Liu C. Fluorescence biosensor for ultrasensitive detection of the available lead based on target biorecognition-induced DNA cyclic assembly. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 905:167253. [PMID: 37741398 DOI: 10.1016/j.scitotenv.2023.167253] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 08/29/2023] [Accepted: 09/20/2023] [Indexed: 09/25/2023]
Abstract
A fluorescence biosensor was developed for the ultrasensitive detection of the available lead in soil samples by coupling with DNAzyme and hairpin DNA cyclic assembly. The biorecognition between lead and 8-17 DNAzyme will cleave the substrate strands (DNA2) and release the trigger DNA (T), which can be used to initiate the DNA assembly reactions among the hairpins (H1, H2, and H3). The formed Y-shaped sensing scaffold (H1-H2-H3) contains active Mg2+-DNAyzmes at three directions. In the presence of Mg2+, the BHQ and FAM modified H4 will be cleaved by the Mg2+-DNAyzme to generate a high fluorescence signal for lead monitoring. The linear range of the fluorescence biosensor is from 1 pM to 100 nM and the detection limit is 0.2 pM. The biosensor also exhibited high selectivity and the nontarget competing heavy metals did not interfere with the detection results. Compare with the traditional method (DTPA+ICP-MS) for the available lead detection, the relative error (Re) is in the range from -8.3 % to 9.5 %. The results indicated that our constructed fluorescence biosensor is robust, accurate, and reliable, and can be applied directly to the detection of the available lead in soil samples without complex extraction steps.
Collapse
Affiliation(s)
- Junhua Chen
- State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550081, China; National-Regional Joint Engineering Research Center for Soil Pollution Control and Remediation in South China, Guangdong Key Laboratory of Integrated Agro-environmental Pollution Control and Management, Institute of Eco-environmental and Soil Sciences, Guangdong Academy of Sciences, Guangzhou 510650, China
| | - Manjia Chen
- National-Regional Joint Engineering Research Center for Soil Pollution Control and Remediation in South China, Guangdong Key Laboratory of Integrated Agro-environmental Pollution Control and Management, Institute of Eco-environmental and Soil Sciences, Guangdong Academy of Sciences, Guangzhou 510650, China
| | - Hui Tong
- National-Regional Joint Engineering Research Center for Soil Pollution Control and Remediation in South China, Guangdong Key Laboratory of Integrated Agro-environmental Pollution Control and Management, Institute of Eco-environmental and Soil Sciences, Guangdong Academy of Sciences, Guangzhou 510650, China
| | - Fei Wu
- State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550081, China
| | - Yizhang Liu
- State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550081, China
| | - Chengshuai Liu
- State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550081, China.
| |
Collapse
|
15
|
Manikandan R, Yoon JH, Chang SC. Emerging Trends in nanostructured materials-coated screen printed electrodes for the electrochemical detection of hazardous heavy metals in environmental matrices. CHEMOSPHERE 2023; 344:140231. [PMID: 37775053 DOI: 10.1016/j.chemosphere.2023.140231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 07/18/2023] [Accepted: 09/18/2023] [Indexed: 10/01/2023]
Abstract
Heavy metal ions (HMIs) have become a significant contaminant in recent years. The increase in heavy metal pollution is a serious situation, requiring progressively robust, fast sensing, highly sensitive, and suitable techniques for heavy metal detection. Compared to other classical analytical methods, electroanalytical techniques, especially stripping voltammetric techniques with modified screen-printed electrodes (SPEs), have several advantages, such as fast sensing, great sensitivity, specificity, and long-time stability. Therefore, these techniques are more suitable for HMI detection. In this review, the nanostructured materials used to coat SPEs for the electrochemical determination of HMI are summarized. Additionally, the electrode fabrication method, modification steps, and electroanalytical study of these materials are systematically discussed. Hence, this review will support the researchers in precisely evaluating the electrochemical HMIs detection through highly sensitive stripping voltammetric techniques using SPE modified with nanostructured carbon and their allotropes, metal, metal oxides and their nanocomposites as sensor materials. Moreover, modified electrodes real time detection of HMIs in different food and environmental samples were briefly discussed.
Collapse
Affiliation(s)
- Ramalingam Manikandan
- Department of Cogno-Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan, 46241, Republic of Korea
| | - Jang-Hee Yoon
- Busan Centre, Korea Basic Science Institute, Busan, 46742, Republic of Korea
| | - Seung-Cheol Chang
- Department of Cogno-Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan, 46241, Republic of Korea.
| |
Collapse
|
16
|
Yuan X, Liang Y, Yang M, Cheng S, Gao N, Zhu Y, Li H. A Nanograss Boron and Nitrogen Co-Doped Diamond Sensor Produced via High-Temperature Annealing for the Detection of Cadmium Ions. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:2955. [PMID: 37999309 PMCID: PMC10675383 DOI: 10.3390/nano13222955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Revised: 11/10/2023] [Accepted: 11/13/2023] [Indexed: 11/25/2023]
Abstract
The high-performance determination of heavy metal ions (Cd2+) in water sources is significant for the protection of public health and safety. We have developed a novel sensor of nanograss boron and nitrogen co-doped diamond (NGBND) to detect Cd2+ using a simple method without any masks or reactive ion etching. The NGBND electrode is constructed based on the co-doped diamond growth mode and the removal of the non-diamond carbon (NDC) from the NGBND/NDC composite. Both the enlarged surface area and enhanced electrochemical performance of the NGBND film are achievable. Scanning electron microscopy, Raman spectroscopy, X-ray photoelectron spectroscopy, cyclic voltammetry, electrochemical impedance spectroscopy, and differential pulse anodic stripping voltammetry (DPASV) were used to characterize the NGBND electrodes. Furthermore, we used a finite element numerical method to research the current density near the tip of NGBND. The NGBND sensor exhibits significant advantages for detecting trace Cd2+ via DPASV. A broad linear range of 1 to 100 μg L-1 with a low detection limit of 0.28 μg L-1 was achieved. The successful application of this Cd2+ sensor indicates considerable promise for the sensitive detection of heavy metal ions.
Collapse
Affiliation(s)
- Xiaoxi Yuan
- State Key Laboratory of Superhard Materials, College of Physics, Jilin University, Changchun 130012, China; (X.Y.); (Y.L.); (S.C.)
- Institute for Interdisciplinary Quantum Information Technology, Jilin Engineering Normal University, Changchun 130052, China
| | - Yaqi Liang
- State Key Laboratory of Superhard Materials, College of Physics, Jilin University, Changchun 130012, China; (X.Y.); (Y.L.); (S.C.)
| | - Mingchao Yang
- Department of Physics, Hebei Normal University of Science and Technology, Qinhuangdao 066000, China;
| | - Shaoheng Cheng
- State Key Laboratory of Superhard Materials, College of Physics, Jilin University, Changchun 130012, China; (X.Y.); (Y.L.); (S.C.)
| | - Nan Gao
- State Key Laboratory of Superhard Materials, College of Physics, Jilin University, Changchun 130012, China; (X.Y.); (Y.L.); (S.C.)
| | - Yongfu Zhu
- Key Laboratory of Automobile Materials, Ministry of Education, School of Materials Science and Engineering, Jilin University, Changchun 130022, China
| | - Hongdong Li
- State Key Laboratory of Superhard Materials, College of Physics, Jilin University, Changchun 130012, China; (X.Y.); (Y.L.); (S.C.)
| |
Collapse
|
17
|
Liu T, Zhang C, Huo S, Zhou Y, Yi Y, Zhu G. Target-Controlled Redox Reaction and Ru(II) Release of a Smart Metal-Organic Framework Nanomaterial for Highly Sensitive Ratiometric Homogeneous Electroanalysis of Cadmium(II). Inorg Chem 2023; 62:17425-17432. [PMID: 37812810 DOI: 10.1021/acs.inorgchem.3c02760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/11/2023]
Abstract
In this work, a highly sensitive ratiometric homogeneous electroanalysis (HEA) strategy of cadmium(II) (Cd2+) was proposed via a Cd2+-controlled redox reaction and Ru(bpy)32+ (Ru(II)) release from a smart metal-organic framework (MOF) nanomaterial. For achieving this purpose, Ru(II) was entrapped ingeniously into the pores of an MOF material (UiO-66-NH2) and subsequently gated by the double-strand hybrids of a Cd2+-aptamer (Apt) and its complementary sequences (CP) to form a novel smart nanomaterial (denoted as Ru@UiO-66-NH2); meanwhile, Fe(III) was selected as an additional probe present in electrolyte to facilitate the Ru(II) redox reaction: Fe(III) + Ru(II) → Fe(II) + Ru(III). Owing to the strong binding effect of the Cd2+ target to the specific Apt, the Apt-CP hybridization at Ru@UiO-66-NH2 would be destroyed in the presence of Cd2+, and the related Apt was further induced away from the smart nanomaterial, leading to the opening of the gate and release of Ru(II). Meanwhile, the released Ru(II) was quickly oxidized chemically by Fe(III) to Ru(III). On the basis of the generated Ru(III) and consumed Fe(III), the ratio of the reduction currents between Ru(III) and Fe(III) exhibits an enhancement and it is dependent on the level of Cd2+; thus, a novel HEA strategy of Cd2+ was then designed. Under the optimal conditions, the HEA sensor shows a wide linearity ranging from 10.0 pM to 500.0 nM, and the achieved detection limit of Cd2+ is 3.3 pM. The as-designed ratiometric HEA strategy not only offers a unique idea to realize a simple and sensitive assay for Cd2+ but also possesses significant potential as an effective tool to be introduced for other target analysis just via altering the specific Apt.
Collapse
Affiliation(s)
- Tingting Liu
- School of Emergency Management, School of the Environment and Safety Engineering, and Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, P. R. China
- Fujian Key Laboratory of Surface and Interface Engineering for High Performance Materials, Xiamen University, Xiamen 361005, P.R. China
| | - Conglin Zhang
- School of Emergency Management, School of the Environment and Safety Engineering, and Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, P. R. China
| | - Shuhao Huo
- School of Emergency Management, School of the Environment and Safety Engineering, and Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, P. R. China
| | - Yifan Zhou
- School of Emergency Management, School of the Environment and Safety Engineering, and Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, P. R. China
| | - Yinhui Yi
- School of Emergency Management, School of the Environment and Safety Engineering, and Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, P. R. China
- Key Laboratory of Synthetic and Biological Colloids, Ministry of Education, Jiangnan University, Wuxi 214122, P. R. China
- Fujian Key Laboratory of Surface and Interface Engineering for High Performance Materials, Xiamen University, Xiamen 361005, P.R. China
- State Environmental Protection Key Laboratory of Monitoring for Heavy Metal Pollutants, Changsha 410019, P.R. China
- The Key Laboratory of Spectroscopy Sensing, Ministry of Agriculture and Rural Affairs, Zhejiang University, Hangzhou 310058, P.R. China
| | - Gangbing Zhu
- School of Emergency Management, School of the Environment and Safety Engineering, and Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, P. R. China
| |
Collapse
|
18
|
Beas-Bernuy LC, Cardenas-Riojas AA, Calderon-Zavaleta SL, Quiroz-Aguinaga U, La Rosa-Toro A, López EO, Asencios YJO, Baena-Moncada AM, Muedas-Taipe G. Cd 2+ Detection by an Electrochemical Electrode Based on MWCNT-Orange Peel Activated Carbon. ACS OMEGA 2023; 8:37341-37352. [PMID: 37841145 PMCID: PMC10569008 DOI: 10.1021/acsomega.3c05154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Accepted: 09/15/2023] [Indexed: 10/17/2023]
Abstract
This study reports the development of a new electrochemical sensor based on a carbon paste electrode (CPE) composed of biomass-based orange peel activated carbon (ACOP) and multiwalled carbon nanotubes (MWCNTs), and this composite is used for the electrochemical detection of cadmium ions (Cd2+). The ACOP/MWCNT composite was characterized by FTIR, Raman, and electrochemical impedance spectroscopy. The electrochemical evaluation of Cd2+ was performed using square wave and cyclic voltammetry. The ACOP/MWCNT-CPE electrochemical sensor exhibited a coefficient of determination r2 of 0.9907, a limit of detection of 0.91 ± 0.79 μmol L-1, and a limit of quantification of 3.00 ± 2.60 μmol L-1. In addition, the developed sensor can selectively detect Cd2+ in the presence of different interferents such as Zn2+, Pb2+, Ni2+, Co2+, Cu2+, and Fe2+ with a relative standard deviation (RSD) close to 100%, carried out in triplicate experiments. The ACOP/MWCNT-CPE presented high sensitivity, stability, and reproducibility and was successfully applied for the detection of Cd2+ in river water samples with recovery rate values ranging from 97.33 to 115.6%, demonstrating to be a very promising analytical alternative for the determination of cadmium ions in this matrix.
Collapse
Affiliation(s)
- Luis C. Beas-Bernuy
- Laboratorio
de Investigación de Electroquímica of Aplicada, Facultad de Ciencias de la Universidad Nacional de
Ingeniería, Av.
Túpac Amaru 210, Rímac, Lima 51, Peru
| | - Andy A. Cardenas-Riojas
- Laboratorio
de Investigación de Electroquímica of Aplicada, Facultad de Ciencias de la Universidad Nacional de
Ingeniería, Av.
Túpac Amaru 210, Rímac, Lima 51, Peru
| | - Sandy L. Calderon-Zavaleta
- Laboratorio
de Investigación de Electroquímica of Aplicada, Facultad de Ciencias de la Universidad Nacional de
Ingeniería, Av.
Túpac Amaru 210, Rímac, Lima 51, Peru
| | - Ulises Quiroz-Aguinaga
- Laboratorio
de Investigación de Electroquímica of Aplicada, Facultad de Ciencias de la Universidad Nacional de
Ingeniería, Av.
Túpac Amaru 210, Rímac, Lima 51, Peru
| | - Adolfo La Rosa-Toro
- Laboratorio
de Investigación de Electroquímica of Aplicada, Facultad de Ciencias de la Universidad Nacional de
Ingeniería, Av.
Túpac Amaru 210, Rímac, Lima 51, Peru
- Centro
para el Desarrollo de Materiales Avanzados y Nanotecnología
(CEMAT), Facultad de Ciencias de la Universidad
Nacional de Ingeniería, Av. Túpac Amaru 210, Rímac, Lima 51, Peru
| | - Elvis O. López
- Department
of Experimental Low Energy Physics, Brazilian
Center for Research in Physics (CBPF), Rio de Janeiro 22290-180, Brazil
| | - Yvan J. O. Asencios
- Institute
of Marine Sciences, Federal University of
São Paulo (UNIFESP), Rua. Maria Máximo, 168, Santos, Sao Paulo 11030-100, Brazil)
| | - Angelica M. Baena-Moncada
- Laboratorio
de Investigación de Electroquímica of Aplicada, Facultad de Ciencias de la Universidad Nacional de
Ingeniería, Av.
Túpac Amaru 210, Rímac, Lima 51, Peru
| | - Golfer Muedas-Taipe
- Laboratorio
de Investigación de Electroquímica of Aplicada, Facultad de Ciencias de la Universidad Nacional de
Ingeniería, Av.
Túpac Amaru 210, Rímac, Lima 51, Peru
| |
Collapse
|
19
|
Li S, Li H, Lu Y, Zhou M, Jiang S, Du X, Guo C. Advanced Textile-Based Wearable Biosensors for Healthcare Monitoring. BIOSENSORS 2023; 13:909. [PMID: 37887102 PMCID: PMC10605256 DOI: 10.3390/bios13100909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 09/19/2023] [Accepted: 09/22/2023] [Indexed: 10/28/2023]
Abstract
With the innovation of wearable technology and the rapid development of biosensors, wearable biosensors based on flexible textile materials have become a hot topic. Such textile-based wearable biosensors promote the development of health monitoring, motion detection and medical management, and they have become an important support tool for human healthcare monitoring. Textile-based wearable biosensors not only non-invasively monitor various physiological indicators of the human body in real time, but they also provide accurate feedback of individual health information. This review examines the recent research progress of fabric-based wearable biosensors. Moreover, materials, detection principles and fabrication methods for textile-based wearable biosensors are introduced. In addition, the applications of biosensors in monitoring vital signs and detecting body fluids are also presented. Finally, we also discuss several challenges faced by textile-based wearable biosensors and the direction of future development.
Collapse
Affiliation(s)
- Sheng Li
- School of Microelectronics and Control Engineering, Changzhou University, Changzhou 213164, China; (S.L.); (H.L.); (Y.L.); (M.Z.); (S.J.)
- CCZU-ARK Institute of Carbon Materials, Nanjing 210012, China
| | - Huan Li
- School of Microelectronics and Control Engineering, Changzhou University, Changzhou 213164, China; (S.L.); (H.L.); (Y.L.); (M.Z.); (S.J.)
| | - Yongcai Lu
- School of Microelectronics and Control Engineering, Changzhou University, Changzhou 213164, China; (S.L.); (H.L.); (Y.L.); (M.Z.); (S.J.)
| | - Minhao Zhou
- School of Microelectronics and Control Engineering, Changzhou University, Changzhou 213164, China; (S.L.); (H.L.); (Y.L.); (M.Z.); (S.J.)
| | - Sai Jiang
- School of Microelectronics and Control Engineering, Changzhou University, Changzhou 213164, China; (S.L.); (H.L.); (Y.L.); (M.Z.); (S.J.)
| | - Xiaosong Du
- School of Microelectronics and Control Engineering, Changzhou University, Changzhou 213164, China; (S.L.); (H.L.); (Y.L.); (M.Z.); (S.J.)
| | - Chang Guo
- CCZU-ARK Institute of Carbon Materials, Nanjing 210012, China
- School of Mechanical Engineering and Rail Transit, Changzhou University, Changzhou 213164, China
| |
Collapse
|
20
|
Sadeghi E, Rahimi F, Azizi Z, Kaki S, Babakhanian A. Fabrication of a sensitive electrochemical sensor based on hybrid polyamide/chromotropic acid nanofibers electrospun on glassy carbon electrode for Hg 2+ sensing in drinking water and canned fish samples. Food Chem 2023; 414:135467. [PMID: 36842206 DOI: 10.1016/j.foodchem.2023.135467] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Revised: 01/03/2023] [Accepted: 01/09/2023] [Indexed: 01/13/2023]
Abstract
In this study, a new electrochemical sensor was designed based on a hybrid of polyamide (PA) and chromotropic acid (CA) nanofibers electrospun on a glassy carbon electrode (GCE) configured as PANFs-CANFs/GCE. The electrochemical response of this sensor showed an excellent electrochemical activity for the detection of Hg2+ ions using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods. The proposed sensor exhibited the prominent electrocatalytic value of (α = 0.60, Log Ks = 3.45 s-1 and Γ = 3.30 × 10 -9 mmol/cm2) as a result of PANFs-CANFs/GCE response to Hg2+ ions. The recommended sensor also demonstrated a linear portion in the calibration curve over the concentration range of 30 to 450 nM with the limit of detection (LOD) and limit of quantitation (LOQ) of 9.98 nM and 29.97 nM, respectively. The fabricated sensor revealed reproducible and repeatable responses with a high level of stability. Therefore, we highly recommend this new electro-spun based sensor for quantifying Hg2+ in drinking water and canned fish samples with the accurate and precise results and no side interferences.
Collapse
Affiliation(s)
- Ehsan Sadeghi
- Department of Food Science and Technology, School of Nutrition Sciences and Food Technology, Research Center for Environmental Determinants of Health (RCEDH), Health Institute, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Faezeh Rahimi
- Department of Chemistry, College of Science, Kermanshah Branch, Islamic Azad University, Kermanshah, Iran
| | - Zohreh Azizi
- Department of Chemistry, College of Science, Kermanshah Branch, Islamic Azad University, Kermanshah, Iran
| | - Samineh Kaki
- Department of Chemistry, College of Science, Tehran Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - Arash Babakhanian
- Department of Chemistry, College of Science, Kermanshah Branch, Islamic Azad University, Kermanshah, Iran.
| |
Collapse
|
21
|
Beitollahi H, Nejad FG, Dourandish Z, Aflatoonian MR. Electrochemical detection of carmoisine in the presence of tartrazine on the surface of screen printed graphite electrode modified with nickel-cobalt layered double hydroxide ultrathin nanosheets. CHEMOSPHERE 2023:139369. [PMID: 37392790 DOI: 10.1016/j.chemosphere.2023.139369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 06/08/2023] [Accepted: 06/27/2023] [Indexed: 07/03/2023]
Abstract
Toxic effluents containing azo dyes are discharged from various industries and they adversely affect water resoures, soil, aquatic ecosystems. Also, excessive use of food azo dyes can be carcinogenic, toxic, and adversely affect human health. Therefore, the determination of food azo dyes is significant from the perspective of human health and aquatic organisms. In the present work, nickel-cobalt layered double hydroxide nanosheets were prepared and analyzed by various techniques (field emission-scanning electron microscopy, X-ray diffraction, and fourier Transform-Infrared spectroscopy). Then, the screen printed graphite electrode modified with nickel-cobalt layered double hydroxide nanosheets was used for the detection of carmoisine. The nickel-cobalt layered double hydroxide nanosheets/screen printed graphite electrode significantly improved the oxidation of carmoisine by increasing the response current and lowering potentials compared to unmodified screen printed graphite electrode. Based on the findings from differential pulse voltammetry, the nickel-cobalt layered double hydroxide nanosheets/screen printed graphite electrode sensor response towards carmoisine was linear (0.3-125.0 μM) with a detection limit of 0.09 μM. A sensitivity of 0.3088 μA μM-1 was achieved. Also, the nickel-cobalt layered double hydroxide nanosheets/screen printed graphite electrode was used for voltammetric detection of carmoisine in the presence of tartrazine. Due to the catalytic activity of prepared layered double hydroxide, the prepared sensor exhibited remarkable separation of the peaks when carmoisine and tartrazine coexist. In addition, the prepared sensor showed good stability. Finally, the proposed sensor had promising applicability for analysis of study analytes in powdered juice and lemon juice, with commendable recoveries between 97.3% and 104.8%.
Collapse
Affiliation(s)
- Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, P.O. Box 76318-85356, Iran.
| | - Fariba Garkani Nejad
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, P.O. Box 76318-85356, Iran
| | - Zahra Dourandish
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, P.O. Box 76318-85356, Iran
| | - Mohammad Reza Aflatoonian
- Leishmaniasis Research Center, Kerman University of Medical Sciences, Kerman, P.O. Box 76169-13555, Iran
| |
Collapse
|
22
|
Jeong M, Bae D, Choi JS. Colorimetric mercury detection with enhanced sensitivity using magnetic-Au hybrid nanoparticles. NANOSCALE ADVANCES 2023; 5:3084-3090. [PMID: 37260498 PMCID: PMC10228351 DOI: 10.1039/d3na00129f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Accepted: 05/15/2023] [Indexed: 06/02/2023]
Abstract
Due to the neural toxicity of mercury, there is a need for the development of on-site detection systems for Hg2+ monitoring. To this end, a new colorimetric mercury detection probe, Fe3O4@SiO2@Au (magnetic-Au; Mag-Au) hybrid nanoparticles, has been developed. The Au on the surface of Mag-Au is an indicator of Hg2+, which forms an AuHg alloy (amalgam) on their surface (Mag-Au@Hg), with excellent peroxidase-like activity. The oxidation of 3,3',5,5'-tetramethylbenzidine by Mag-Au@Hg resulted in a color change of the indicator solution, which was enhanced with increasing Hg2+ concentration. Mag-Au can be used to detect Hg2+ at nanomolar concentrations. Additionally, magnetic separation can be used to easily purify and concentrate the Mag-Au@Hg from samples, and thus avoid interference from unwanted residues or colored samples. The feasibility of Mag-Au for Hg2+ detection was tested with an artificial urine solution and it can be used to detect Hg2+ in various real samples, such as river water, seawater, food, and biological samples.
Collapse
Affiliation(s)
- Miseon Jeong
- Department of Chemical and Biological Engineering, Hanbat National University Daejeon 34158 Korea
| | - Dahyun Bae
- Department of Chemical and Biological Engineering, Hanbat National University Daejeon 34158 Korea
| | - Jin-Sil Choi
- Department of Chemical and Biological Engineering, Hanbat National University Daejeon 34158 Korea
| |
Collapse
|
23
|
Bhuvaneswari K, Radha S, Sreeja BS, Senthil Kumar P. Development of in-situ electrochemical heavy metal ion sensor using integrated 1D/0D/1D hybrid by MWCNT and CQDs supported MnO 2 nanomaterial. ENVIRONMENTAL RESEARCH 2023; 225:115570. [PMID: 36868450 DOI: 10.1016/j.envres.2023.115570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 10/23/2022] [Accepted: 02/22/2023] [Indexed: 06/18/2023]
Abstract
An integrated 1D/0D/1D hybrid nanomaterial was prepared from MWCNT supported carbon quantum dots @ MnO2 nanomaterial for a sensitive and selective electrochemical heavy metal ion sensor by hydrothermal methods. The developed nanomaterials were characterized by various analytical methods such as FESEM, HRTEM, XRD, FTIR, EDX and elemental mapping study, and also its electrochemical properties of the prepared samples were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) analysis. Differential pulse voltammetry (DPV) analysis has been used to investigate the quantitative detection of heavy metal ions such as cadmium and chromium on modified electrodes under optimal conditions. The in-situ electrochemical sensitivity and selectivity of the samples were determined by varying various parameters, such as the concentration of heavy metal ions, different electrolytes and electrolyte pH. The observed DPV results show that prepared MWCNT (0.05 wt%) and CQD (0.1 wt%) supported MnO2 nanoparticles show effective detection response for chromium (IV) metal ion. In particular, 0D CQD, 1D MWCNT, and MnO2 hybrid nanostructures produced a synergistic effect among them, resulting in strong electrochemical performance of the prepared samples against the target metal ions.
Collapse
Affiliation(s)
- K Bhuvaneswari
- Materials and MEMS Laboratory, Department of Electronics and Communication Engineering, Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, 603 110, Tamil Nadu, India.
| | - S Radha
- Materials and MEMS Laboratory, Department of Electronics and Communication Engineering, Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, 603 110, Tamil Nadu, India.
| | - B S Sreeja
- Materials and MEMS Laboratory, Department of Electronics and Communication Engineering, Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, 603 110, Tamil Nadu, India; Centre of Excelllence in Water Research (CEWAR), Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, 603 110, Tamil Nadu, India
| | - P Senthil Kumar
- Department of Chemical Engineering, Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, 603 110, Tamil Nadu, India; Centre of Excelllence in Water Research (CEWAR), Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, 603 110, Tamil Nadu, India
| |
Collapse
|
24
|
Hu T, Lai Q, Fan W, Zhang Y, Liu Z. Advances in Portable Heavy Metal Ion Sensors. SENSORS (BASEL, SWITZERLAND) 2023; 23:4125. [PMID: 37112466 PMCID: PMC10143460 DOI: 10.3390/s23084125] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 04/16/2023] [Accepted: 04/18/2023] [Indexed: 06/19/2023]
Abstract
Heavy metal ions, one of the major pollutants in the environment, exhibit non-degradable and bio-chain accumulation characteristics, seriously damage the environment, and threaten human health. Traditional heavy metal ion detection methods often require complex and expensive instruments, professional operation, tedious sample preparation, high requirements for laboratory conditions, and operator professionalism, and they cannot be widely used in the field for real-time and rapid detection. Therefore, developing portable, highly sensitive, selective, and economical sensors is necessary for the detection of toxic metal ions in the field. This paper presents portable sensing based on optical and electrochemical methods for the in situ detection of trace heavy metal ions. Progress in research on portable sensor devices based on fluorescence, colorimetric, portable surface Raman enhancement, plasmon resonance, and various electrical parameter analysis principles is highlighted, and the characteristics of the detection limits, linear detection ranges, and stability of the various sensing methods are analyzed. Accordingly, this review provides a reference for the design of portable heavy metal ion sensing.
Collapse
|
25
|
Musa AM, Kiely J, Luxton R, Honeychurch KC. An Electrochemical Screen-Printed Sensor Based on Gold-Nanoparticle-Decorated Reduced Graphene Oxide-Carbon Nanotubes Composites for the Determination of 17-β Estradiol. BIOSENSORS 2023; 13:bios13040491. [PMID: 37185565 PMCID: PMC10136424 DOI: 10.3390/bios13040491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/17/2023]
Abstract
In this study, a screen-printed electrode (SPE) modified with gold-nanoparticle-decorated reduced graphene oxide-carbon nanotubes (rGO-AuNPs/CNT/SPE) was used for the determination of estradiol (E2). The AuNPs were produced through an eco-friendly method utilising plant extract, eliminating the need for severe chemicals, and remove the requirements of sophisticated fabrication methods and tedious procedures. In addition, rGO-AuNP serves as a dispersant for the CNT to improve the dispersion stability of CNTs. The composite material, rGO-AuNPs/CNT, underwent characterisation through scanning electron microscopy (SEM), ultraviolet-visible absorption spectroscopy (UV-vis), Fourier-transform infrared (FTIR) spectroscopy, and atomic force microscopy (AFM). The electrochemical performance of the modified SPE for estradiol oxidation was characterised using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The rGO-AuNPs/CNT/SPE exhibited a notable improvement compared to bare/SPE and GO-CNT/SPE, as evidenced by the relative peak currents. Additionally, we employed a baseline correction algorithm to accurately adjust the sensor response while eliminating extraneous background components that are typically present in voltammetric experiments. The optimised estradiol sensor offers linear sensitivity from 0.05-1.00 µM, with a detection limit of 3 nM based on three times the standard deviation (3δ). Notably, this sensing approach yields stable, repeatable, and reproducible outcomes. Assessment of drinking water samples indicated an average recovery rate of 97.5% for samples enriched with E2 at concentrations as low as 0.5 µM%, accompanied by only a modest coefficient of variation (%CV) value of 2.7%.
Collapse
Affiliation(s)
- Auwal M Musa
- Institute of Bio-Sensing Technology (IBST), University of the West of England, Bristol BS16 1QY, UK
| | - Janice Kiely
- Centre for Research in Biosciences (CRIB), School of Applied Sciences, University of the West of England, Bristol BS16 1QY, UK
| | - Richard Luxton
- Centre for Research in Biosciences (CRIB), School of Applied Sciences, University of the West of England, Bristol BS16 1QY, UK
| | - Kevin C Honeychurch
- Institute of Bio-Sensing Technology (IBST), University of the West of England, Bristol BS16 1QY, UK
- Centre for Research in Biosciences (CRIB), School of Applied Sciences, University of the West of England, Bristol BS16 1QY, UK
| |
Collapse
|
26
|
Ivanišević I. The Role of Silver Nanoparticles in Electrochemical Sensors for Aquatic Environmental Analysis. SENSORS (BASEL, SWITZERLAND) 2023; 23:3692. [PMID: 37050752 PMCID: PMC10099384 DOI: 10.3390/s23073692] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/30/2023] [Accepted: 03/31/2023] [Indexed: 06/19/2023]
Abstract
With rapidly increasing environmental pollution, there is an urgent need for the development of fast, low-cost, and effective sensing devices for the detection of various organic and inorganic substances. Silver nanoparticles (AgNPs) are well known for their superior optoelectronic and physicochemical properties, and have, therefore, attracted a great deal of interest in the sensor arena. The introduction of AgNPs onto the surface of two-dimensional (2D) structures, incorporation into conductive polymers, or within three-dimensional (3D) nanohybrid architectures is a common strategy to fabricate novel platforms with improved chemical and physical properties for analyte sensing. In the first section of this review, the main wet chemical reduction approaches for the successful synthesis of functional AgNPs for electrochemical sensing applications are discussed. Then, a brief section on the sensing principles of voltammetric and amperometric sensors is given. The current utilization of silver nanoparticles and silver-based composite nanomaterials for the fabrication of voltammetric and amperometric sensors as novel platforms for the detection of environmental pollutants in water matrices is summarized. Finally, the current challenges and future directions for the nanosilver-based electrochemical sensing of environmental pollutants are outlined.
Collapse
Affiliation(s)
- Irena Ivanišević
- Department of General and Inorganic Chemistry, Faculty of Chemical Engineering and Technology, University of Zagreb, Marulićev trg 19, 10000 Zagreb, Croatia
| |
Collapse
|
27
|
Yan Y, Liu Z, Xie P, Huang S, Chen J, Caddeo F, Liu X, Huang Q, Jin M, Shui L. Sensitive electrochemical assay of acetaminophen based on 3D-hierarchical mesoporous carbon nanosheets. J Colloid Interface Sci 2023; 634:509-520. [PMID: 36542979 DOI: 10.1016/j.jcis.2022.12.022] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 11/30/2022] [Accepted: 12/06/2022] [Indexed: 12/14/2022]
Abstract
Acetaminophen plays a key role in first-line Covid-19 cure as a supportive therapy of fever and pain. However, overdose of acetaminophen may give rise to severe adverse events such as acute liver failure in individual. In this work, 3D-hierarchical mesoporous carbon nanosheet (hMCNS) microspheres with superior properties were fabricated using simple and quick strategy and applied for sensitive quantification of acetaminophen in pharmaceutical formulation and rat plasmas after administration. The hMCNS microspheres are prepared via chemical etching of zinc oxide (ZnO) nanoparticles from a zinc-gallic acid precursor composite (Zn-GA) synthesized by high-temperature anaerobic pyrolysis. The obtained hMCNS could enhance analytes accessibility and accelerate proton transfer in the interface, hence increasing the electrochemical performance. Under optimized experimental conditions, the proposed electrochemical sensor achieves a detection limit of 3.5 nM for acetaminophen. The prepared electrochemical sensor has been successfully applied for quantification of acetaminophen in pharmaceutical formulations and the rat plasma samples before and after administration. Meanwhile, this sensor is compared with high-performance liquid chromatography (HPLC) as a reference technology, showing an excellent accuracy. Such an electrochemical sensor has great potential and economic benefits for applications in the fields of pharmaceutical assay and therapeutic drug monitoring (TDM).
Collapse
Affiliation(s)
- Yu Yan
- International Joint Laboratory of Optofluidic Technology and System, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics & School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, PR China
| | - Zhenping Liu
- International Joint Laboratory of Optofluidic Technology and System, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics & School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, PR China; University of Hamburg, Institute for Nanostructure and Solid-State Physics, Center for Hybrid Nanostructures, Hamburg, Germany.
| | - Peng Xie
- International Joint Laboratory of Optofluidic Technology and System, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics & School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, PR China
| | - Shuqing Huang
- International Joint Laboratory of Optofluidic Technology and System, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics & School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, PR China
| | - Jiamei Chen
- International Joint Laboratory of Optofluidic Technology and System, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics & School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, PR China
| | - Francesco Caddeo
- University of Hamburg, Institute for Nanostructure and Solid-State Physics, Center for Hybrid Nanostructures, Hamburg, Germany
| | - Xin Liu
- University of Hamburg, Institute for Nanostructure and Solid-State Physics, Center for Hybrid Nanostructures, Hamburg, Germany
| | - Qiuju Huang
- Guangxi Key Laboratory of Bioactive Molecules Research and Evaluation, College of Pharmacy, Guangxi Medical University, Nanning 530021, PR China
| | - Mingliang Jin
- International Joint Laboratory of Optofluidic Technology and System, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics & School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, PR China; International Academy of Optoelectronics at Zhaoqing, South China Normal University, Zhaoqing 526238, PR China
| | - Lingling Shui
- International Joint Laboratory of Optofluidic Technology and System, National Center for International Research on Green Optoelectronics, South China Academy of Advanced Optoelectronics & School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, PR China; Guangdong Provincial Key Laboratory of Nanophotonic Functional Materials and Devices, South China Normal University, Guangzhou 510006, PR China.
| |
Collapse
|
28
|
Wang Y, Zhai H, Guo Q, Zhang Y, Gao X, Yang Q, Sun X, Guo Y, Zhang Y. A dual-modal electrochemical aptasensor based on intelligent DNA Walker with cascade signal amplification powered by Nb.BbvCI for Pb 2. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 863:160910. [PMID: 36528096 DOI: 10.1016/j.scitotenv.2022.160910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 12/07/2022] [Accepted: 12/09/2022] [Indexed: 06/17/2023]
Abstract
As a unique nanomachine, DNA Walker can move continuously along a specific orbit to amplify signal. Therefore, based on DNA Walker and endonuclease assisted signal amplification strategy, a novel dual-mode visual electrochemical aptasensor was constructed for the detection of Pb2+. Ceric dioxide@mesoporous carbon (CeO2/CS)@AuNPs not only could improve the conductivity of sensing interface but also could fix the aptamer. DNA Walker moved on the surface of the electrode to realize the pairing with the Ag-γFe2O3/cDNA probe, forming a special base sequence that could be spliced by the Nb.BbvCI. Under the action of endonuclease Nb.BbvCI, the Ag-γFe2O3/cDNA probe was continuously sheared and the amount on the electrode was decreased to amplify the signal. Besides, the nanoenzyme of Ag-γFe2O3 could catalyze 3'3'5'5'-tetramethylbenzidine (TMB) to blue color realizing the visual detection of Pb2+. The sensor has been successfully applied to the visual and accurate rapid detection of Pb2+ in aquatic products. The fabricated method of the sensor open up a new way for visual and accurate the detection of environmental pollutants.
Collapse
Affiliation(s)
- Yue Wang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo 255000, China; Shandong Province Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo 255000, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo 255000, China
| | - Hongguo Zhai
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo 255000, China; Shandong Province Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo 255000, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo 255000, China
| | - Qi Guo
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo 255000, China; Shandong Province Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo 255000, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo 255000, China
| | - Yuhao Zhang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo 255000, China; Shandong Province Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo 255000, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo 255000, China
| | - Xiaolin Gao
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo 255000, China; Shandong Province Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo 255000, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo 255000, China
| | - Qingqing Yang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo 255000, China; Shandong Province Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo 255000, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo 255000, China
| | - Xia Sun
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo 255000, China; Shandong Province Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo 255000, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo 255000, China
| | - Yemin Guo
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo 255000, China; Shandong Province Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo 255000, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo 255000, China
| | - Yanyan Zhang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo 255000, China; Shandong Province Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo 255000, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo 255000, China.
| |
Collapse
|
29
|
The innovative and accurate detection of heavy metals in foods: A critical review on electrochemical sensors. Food Control 2023. [DOI: 10.1016/j.foodcont.2023.109743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2023]
|
30
|
Wang L, Cao H, Jiang H, Fang Y, Jiang D. A novel 3D bio-printing “liver lobule” microtissue biosensor for the detection of AFB1. Food Res Int 2023; 168:112778. [PMID: 37120227 DOI: 10.1016/j.foodres.2023.112778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Revised: 02/14/2023] [Accepted: 03/26/2023] [Indexed: 04/03/2023]
Abstract
In this paper, a novel "liver lobule" microtissue biosensor based on 3D bio-printing is developed to rapidly determine aflatoxin B1 (AFB1). Methylacylated Hyaluronic acid (HAMA) hydrogel, HepG2 cells, and carbon nanotubes are used to construct "liver lobule" models. In addition, 3D bio-printing is used to perform high-throughput and standardized preparation in order to simulate the organ morphology and induce functional formation. Afterwards, based on the electrochemical rapid detection technology, a 3D bio-printed "liver lobule" microtissue is immobilized on the screen-printed electrode, and the mycotoxin is detected by differential pulse voltammetry (DPV). The DPV response increases with the concentration of AFB1 in the range of 0.1-3.5 μg/mL. The linear detection range is 0.1-1.5 μg/mL and the calculated lowest detection limit is 0.039 μg/mL. Thus, this study develops a new mycotoxin detection method based on the 3D printing technology, which has high stability and reproducibility. It has wide application prospects in the field of detection and evaluation of food hazards.
Collapse
Affiliation(s)
- Lifeng Wang
- College of Food Science and Engineering, Collaborative Innovation Center for Modern Grain Circulation and Safety, Key Laboratory of Grains and Oils Quality Control and Processing, Nanjing University of Finance and Economics, Nanjing, Jiangsu 210023, PR China
| | - Hanwen Cao
- College of Food Science and Engineering, Collaborative Innovation Center for Modern Grain Circulation and Safety, Key Laboratory of Grains and Oils Quality Control and Processing, Nanjing University of Finance and Economics, Nanjing, Jiangsu 210023, PR China
| | - Hui Jiang
- Key Laboratory of Detection and Traceability Technology of Foodborne Pathogenic Bacteria for Jiangsu Province Market Regulation, Nanjing Institute for Food and Drug Control, Nanjing, Jiangsu 210038, PR China
| | - Yan Fang
- College of Food Science and Engineering, Collaborative Innovation Center for Modern Grain Circulation and Safety, Key Laboratory of Grains and Oils Quality Control and Processing, Nanjing University of Finance and Economics, Nanjing, Jiangsu 210023, PR China
| | - Donglei Jiang
- College of Food Science and Engineering, Collaborative Innovation Center for Modern Grain Circulation and Safety, Key Laboratory of Grains and Oils Quality Control and Processing, Nanjing University of Finance and Economics, Nanjing, Jiangsu 210023, PR China.
| |
Collapse
|
31
|
Determination of Heavy Metal Ions in Infant Milk Powder Using a Nanoporous Carbon Modified Disposable Sensor. Foods 2023; 12:foods12040730. [PMID: 36832804 PMCID: PMC9956227 DOI: 10.3390/foods12040730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 01/30/2023] [Accepted: 02/04/2023] [Indexed: 02/10/2023] Open
Abstract
Due to the risk of heavy metal pollution in infant milk powder, it is significant to establish effective detection methods. Here, a screen-printed electrode (SPE) was modified with nanoporous carbon (NPC) to detect Pb(II) and Cd(II) in infant milk powder using an electrochemical method. Using NPC as a functional nanolayer facilitated the electrochemical detection of Pb(II) and Cd(II) due to its efficient mass transport and large adsorption capacity. Linear responses were obtained for Pb (II) and Cd(II) in the range from 1 to 60 µg L-1 and 5 to 70 µg L-1, respectively. The limit of detection was 0.1 µg L-1 for Pb(II) and 1.67 µg L-1 for Cd(II). The reproducibility, stability, and anti-interference performance of the prepared sensor were tested as well. The heavy metal ion detection performance in the extracted infant milk powder shows that the developed SPE/NPC possesses the ability to detect Pb(II) and Cd(II) in milk powder.
Collapse
|
32
|
Emerging insights into the use of carbon-based nanomaterials for the electrochemical detection of heavy metal ions. Coord Chem Rev 2023. [DOI: 10.1016/j.ccr.2022.214920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
33
|
Ren Y, Jin L, Zeng H, Busquets R, He G, Deng S, He Q, Khan MR, Deng R, Chi Y. Primer-Engineered Transferase Enzyme for One-Pot and Amplified Detection of Cobalt Pollution and Peptide Remover Screening. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2023; 71:877-883. [PMID: 36563311 DOI: 10.1021/acs.jafc.2c07223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Extensive consumption of cobalt in the chemical field such as for battery materials, alloy, pigments, and dyes has aggravated the pollution of cobalt both in food and the environment, and assays for its on-site monitoring are urgently demanded. Herein, we utilized enzyme dependence on metal cofactors to develop terminal transferase (TdT) as a recognition element, achieving a one-pot sensitive and specific assay for detecting cobalt pollution. We engineered a 3'-OH terminus primer to improve the discrimination capacity of TdT for Co2+ from other bivalent cations. The TdT extension reaction amplified the recognition of Co2+ and yielded a limit of detection of 0.99 μM for Co2+ detection. Then, the TdT-based assay was designed to precisely detect cobalt in food and agricultural soil samples. By end-measurement of fluorescence using a microplate reader, the multiplexing assay enabled the rapid screening of the peptide remover for cobalt pollution. The TdT-based assay can be a promising tool for cobalt pollution monitoring and control.
Collapse
Affiliation(s)
- Yao Ren
- College of Biomass Science and Engineering, Healthy Food Evaluation Research Center, Sichuan University, Chengdu, Sichuan 610065, China
| | - Lulu Jin
- College of Biomass Science and Engineering, Healthy Food Evaluation Research Center, Sichuan University, Chengdu, Sichuan 610065, China
| | - Hongling Zeng
- College of Biomass Science and Engineering, Healthy Food Evaluation Research Center, Sichuan University, Chengdu, Sichuan 610065, China
| | - Rosa Busquets
- School of Life Sciences, Pharmacy and Chemistry, Kingston University London, Penrhyn Road, KT1 2EE Kingston Upon Thames, United Kingdom
| | - Guiping He
- College of Biomass Science and Engineering, Healthy Food Evaluation Research Center, Sichuan University, Chengdu, Sichuan 610065, China
| | - Sha Deng
- College of Biomass Science and Engineering, Healthy Food Evaluation Research Center, Sichuan University, Chengdu, Sichuan 610065, China
| | - Qiang He
- College of Biomass Science and Engineering, Healthy Food Evaluation Research Center, Sichuan University, Chengdu, Sichuan 610065, China
| | - Mohammad Rizwan Khan
- Department of Chemistry, College of Science, King Saud University, Riyadh 11451, Saudi Arabia
| | - Ruijie Deng
- College of Biomass Science and Engineering, Healthy Food Evaluation Research Center, Sichuan University, Chengdu, Sichuan 610065, China
| | - Yuanlong Chi
- College of Biomass Science and Engineering, Healthy Food Evaluation Research Center, Sichuan University, Chengdu, Sichuan 610065, China
| |
Collapse
|
34
|
Lv H, Zhang G, Yang W, Dai X, Huang Y, Ni J, Wang Q. Portable anti-fouling electrochemical sensor for soil heavy metal ions detection based on the screen-printed carbon electrode modified with silica isoporous membrane. J Electroanal Chem (Lausanne) 2023. [DOI: 10.1016/j.jelechem.2023.117141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
35
|
Guo M, Nei R, Wang J, Ai J, Dong Y, Zhao H, Gao Q. Sensitive detection of folate receptor-positive circulating tumor cells based on intracellular uptake of the PbS nanoparticle cluster-loaded phospholipid micelles decorated with folic acid in combination with E-DNA sensor. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
36
|
Yu L, Sun L, Zhang Q, Zhou Y, Zhang J, Yang B, Xu B, Xu Q. Nanomaterials-Based Ion-Imprinted Electrochemical Sensors for Heavy Metal Ions Detection: A Review. BIOSENSORS 2022; 12:bios12121096. [PMID: 36551065 PMCID: PMC9775266 DOI: 10.3390/bios12121096] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Revised: 11/24/2022] [Accepted: 11/25/2022] [Indexed: 05/13/2023]
Abstract
Heavy metal ions (HMIs) pose a serious threat to the environment and human body because they are toxic and non-biodegradable and widely exist in environmental ecosystems. It is necessary to develop a rapid, sensitive and convenient method for HMIs detection to provide a strong guarantee for ecology and human health. Ion-imprinted electrochemical sensors (IIECSs) based on nanomaterials have been regarded as an excellent technology because of the good selectivity, the advantages of fast detection speed, low cost, and portability. Electrode surfaces modified with nanomaterials can obtain excellent nano-effects, such as size effect, macroscopic quantum tunneling effect and surface effect, which greatly improve its surface area and conductivity, so as to improve the detection sensitivity and reduce the detection limit of the sensor. Hence, the present review focused on the fundamentals and the synthetic strategies of ion-imprinted polymers (IIPs) and IIECSs for HMIs detection, as well as the applications of various nanomaterials as modifiers and sensitizers in the construction of HMIIECSs and the influence on the sensing performance of the fabricated sensors. Finally, the potential challenges and outlook on the future development of the HMIIECSs technology were also highlighted. By means of the points presented in this review, we hope to provide some help in further developing the preparation methods of high-performance HMIIECSs and expanding their potential applications.
Collapse
Affiliation(s)
- Liangyun Yu
- School of Light Industry, Beijing Technology and Business University, No. 11 Fucheng Road, Haidian District, Beijing 100048, China
| | - Liangju Sun
- School of Light Industry, Beijing Technology and Business University, No. 11 Fucheng Road, Haidian District, Beijing 100048, China
| | - Qi Zhang
- School of Environmental Science and Engineering, Yancheng Institute of Technology, Yancheng 224051, China
| | - Yawen Zhou
- School of Light Industry, Beijing Technology and Business University, No. 11 Fucheng Road, Haidian District, Beijing 100048, China
| | - Jingjing Zhang
- School of Light Industry, Beijing Technology and Business University, No. 11 Fucheng Road, Haidian District, Beijing 100048, China
| | - Bairen Yang
- School of Environmental Science and Engineering, Yancheng Institute of Technology, Yancheng 224051, China
| | - Baocai Xu
- School of Light Industry, Beijing Technology and Business University, No. 11 Fucheng Road, Haidian District, Beijing 100048, China
- Correspondence: (B.X.); (Q.X.); Tel.: +86-514-8797-5257 (Q.X.)
| | - Qin Xu
- College of Chemistry and Engineering, Yangzhou University, Yangzhou 225002, China
- Correspondence: (B.X.); (Q.X.); Tel.: +86-514-8797-5257 (Q.X.)
| |
Collapse
|
37
|
Screen-printed electrochemical sensors for environmental monitoring of heavy metal ion detection. REV CHEM ENG 2022. [DOI: 10.1515/revce-2022-0002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Abstract
Heavy metal ions (HMIs) are known to cause severe damages to the human body and ecological environment. And considering the current alarming situation, it is crucial to develop a rapid, sensitive, robust, economical and convenient method for their detection. Screen printed electrochemical technology contributes greatly to this task, and has achieved global attention. It enabled the mass transmission rate and demonstrated ability to control the chemical nature of the measure media. Besides, the technique offers advantages like linear output, quick response, high selectivity, sensitivity and stability along with low power requirement and high signal-to-noise ratio. Recently, the performance of SPEs has been improved employing the most effective and promising method of the incorporation of different nanomaterials into SPEs. Especially, in electrochemical sensors, the incorporation of nanomaterials has gained extensive attention for HMIs detection as it exhibits outstanding features like broad electrochemical window, large surface area, high conductivity, selectivity and stability. The present review focuses on the recent progress in the field of screen-printed electrochemical sensors for HMIs detection using nanomaterials. Different fabrication methods of SPEs and their utilization for real sample analysis of HMIs using various nanomaterials have been extensively discussed. Additionally, advancement made in this field is also discussed taking help of the recent literature.
Collapse
|
38
|
Dahake RV, Bansiwal A. Disposable Sensors for Heavy Metals Detection: A Review of Carbon and Non‐Noble Metal‐Based Receptors. ChemistrySelect 2022. [DOI: 10.1002/slct.202202824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Rashmi V. Dahake
- CSIR-National Environmental Engineering Research Institute(NEERI) Nagpur
- Academy of Scientific and Innovative Research (AcSIR) Ghaziabad Uttar Pradesh
| | - Amit Bansiwal
- CSIR-National Environmental Engineering Research Institute(NEERI) Nagpur
| |
Collapse
|
39
|
Xu M, Wang X, Liu X. Detection of Heavy Metal Ions by Ratiometric Photoelectric Sensor. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2022; 70:11468-11480. [PMID: 36074997 DOI: 10.1021/acs.jafc.2c03916] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
In recent years, heavy metal pollution has become increasingly serious. Heavy metals exist in an environment mainly in the form of ions (heavy metal ions, HMs). They can contaminate food, water, soil, and the atmosphere, leading to serious harm to plants and animals. With high bioavailability and nonbiodegradability, HMs can accumulate through biomagnification. Consequently, heavy metal pollution has become the cause of many fatal diseases threatening human health and ecological environment. Therefore, the accurate detection of HMs is vital and necessary. In this paper, the harm and limit standards of heavy metals were systematically summarized and the common analysis methods were overviewed and compared. Specifically, the latest research progress of ratiometric photoelectric sensor, including optical and electrical sensor, were mainly described. The research status and advantages and disadvantages of a photoelectric sensor were summarized. Furthermore, the future directions were proposed, which provided the reference for the further research and application of the ratiometric photoelectric sensor.
Collapse
Affiliation(s)
- Mingming Xu
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Xiaoying Wang
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Xiangping Liu
- Nanjing Municipal Center for Disease Control and Prevention, Nanjing 210003, China
| |
Collapse
|
40
|
Radinović K, Milikić J, Balčiūnaitė A, Sukackienė Z, Bošković M, Tamašauskaitė-Tamašiūnaitė L, Šljukić B. Low Au-content CoAu electrodes for environmental applications. RSC Adv 2022; 12:26134-26146. [PMID: 36275101 PMCID: PMC9475402 DOI: 10.1039/d2ra04828k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Accepted: 09/06/2022] [Indexed: 11/21/2022] Open
Abstract
Six cobalt gold (CoAu) electrodes were prepared by electroless deposition using different gold-containing solutions (acidic and weakly acidic) and different Au deposition times. Characterization of CoAu electrodes was done by scanning electron microscopy with energy-dispersive X-ray spectroscopy, N2-sorption, and X-ray powder diffraction techniques. The possibility of using the prepared electrodes in environmental applications, i.e., for the electrochemical sensing of a trace amount of arsenic(iii) in weakly alkaline media was assessed. Employing the CoAu electrode (prepared by immersing Co/Cu into 1 mM HAuCl4 (pH 1.8) at 30 °C for 30 s) under optimized conditions (deposition potential -0.7 V and deposition time of 60 s), a low limit of detection of 2.16 ppb was obtained. Finally, this CoAu electrode showed activity for arsenic oxidation in the presence of Cu(ii) as a model interferent as well as in real samples. Furthermore, the use of CoAu electrode as an anode in fuel cells, namely, direct borohydride - hydrogen peroxide fuel cells was also assessed. A peak power density of 191 mW cm-2 was attained at 25 °C for DBHPFC with CoAu anode at a current density of 201 mA cm-2 and cell voltage of 0.95 V, respectively. The peak power density further increased with the increase of the operating temperature to 55 °C.
Collapse
Affiliation(s)
- Kristina Radinović
- University of Belgrade, Faculty of Physical Chemistry Studentski trg 12-16 Belgrade 11158 Serbia
| | - Jadranka Milikić
- University of Belgrade, Faculty of Physical Chemistry Studentski trg 12-16 Belgrade 11158 Serbia
| | - Aldona Balčiūnaitė
- Center for Physical Sciences and Technology Saulėtekio ave. 3 Vilnius LT-10257 Lithuania
| | - Zita Sukackienė
- Center for Physical Sciences and Technology Saulėtekio ave. 3 Vilnius LT-10257 Lithuania
| | - Marko Bošković
- University of Belgrade, Institute of Chemistry, Technology, and Metallurgy, Department of Microelectronic Technologies Njegoševa 12 Belgrade 11000 Serbia
| | | | - Biljana Šljukić
- University of Belgrade, Faculty of Physical Chemistry Studentski trg 12-16 Belgrade 11158 Serbia
- Center of Physics and Engineering of Advanced Materials, Laboratory for Physics of Materials and Emerging Technologies, Chemical Engineering Department, Instituto Superior Técnico, Universidade de Lisboa Lisbon1049-001 Portugal
| |
Collapse
|
41
|
Liuzhu Z, Sekar S, Chen J, Lee S, Kim DY, Manikandan R. A polyrutin/AgNPs coated GCE for simultaneous anodic stripping voltammetric determination of Pb(II) and Cd(II)ions in environmental samples. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2022.129082] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
42
|
Malik R, Joshi N, Tomer VK. Functional graphitic carbon (IV) nitride: A versatile sensing material. Coord Chem Rev 2022. [DOI: 10.1016/j.ccr.2022.214611] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
43
|
Shao Y, Dong Y, Fan L, Xu W, Bin L, Wang L, Li D, Zhao S. A highly sensitive aptasensor based on 3D-rGO/AuNPs for Hg2+ determination using HCR amplification strategy triggered by T-Hg2+-T. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
44
|
Patle A, Kurrey R, Deb MK, Patle TK, Sinha D, Shrivas K. Analytical approaches on some selected toxic heavy metals in the environment and their socio-environmental impacts: A meticulous review. J INDIAN CHEM SOC 2022. [DOI: 10.1016/j.jics.2022.100545] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
45
|
Ultrasensitive detection and application of estradiol based on nucleic acid aptamer and circulating amplification technology. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116284] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
46
|
Recent advances in the construction of functional nucleic acids with isothermal amplification for heavy metal ions sensor. Microchem J 2022. [DOI: 10.1016/j.microc.2021.107077] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
47
|
Electrochemical sensors for metal ions. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2022. [DOI: 10.1016/j.cjac.2022.100090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
48
|
Xia Y, Zhao Y, Ai F, Yi Y, Liu T, Lin H, Zhu G. N and P co-doped MXenes nanoribbons for electrodeposition-free stripping analysis of Cu(II) and Hg(II). JOURNAL OF HAZARDOUS MATERIALS 2022; 425:127974. [PMID: 34883378 DOI: 10.1016/j.jhazmat.2021.127974] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 11/29/2021] [Accepted: 11/30/2021] [Indexed: 06/13/2023]
Abstract
The present electrochemical stripping analysis (ESA) for multiple heavy metal ions (HMI) generally requires an electrodeposition process at a very low potential below -1.0 V, which inevitably makes the sensing procedures more complex, inefficient and power-wasting. Meanwhile, the emerging MXenes rising-star materials have been studied in various fields recently. While there are only few reports focusing on the heteroatom doping of MXenes, especially no doping-MXenes for electroanalysis. Based on these issues, a novel multifunctional heteroatoms-doped MXenes nanomaterial, N and P co-doped Ti3C2Tx MXenes nanoribbons (N,P-Ti3C2TxR), was prepared herein for the first time, and then N,P-Ti3C2TxR was used as electrode material to propose an electrodeposition-free ESA strategy for multiple HMI (Cu2+, Hg2+). Owing to the unique spontaneous adsorption and reducing capacities of N,P-Ti3C2TxR towards Cu2+ and Hg2+ coupled with the excellent sensing performances, Cu2+ and Hg2+ can undergo self-reduction to be preconcentrated on N,P-Ti3C2TxR surface with the form of Cu0 and Hg0, thus a simple and ultrasensitive electrodeposition-free ESA platform was developed successfully for the simultaneous detection of Cu2+and Hg2+. This work opened a new pathway for the detection for multiple HMI and the preparation/application of heteroatoms doping MXenes.
Collapse
Affiliation(s)
- Yixuan Xia
- School of the Environment and Safety Engineering, Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, PR China
| | - Yong Zhao
- Guangzhou Baiyun Airport Customs Comprehensive Technical Service Center, Guangzhou Baiyun Airport Customs District People's Republic of China, Guangzhou 510470, PR China
| | - Fengxiang Ai
- School of the Environment and Safety Engineering, Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, PR China
| | - Yinhui Yi
- School of the Environment and Safety Engineering, Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, PR China
| | - Tingting Liu
- School of the Environment and Safety Engineering, Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, PR China
| | - Huiyu Lin
- Fujian Key Laboratory of Functional Marine Sensing Materials, Ocean College, Minjiang University, PR China
| | - Gangbing Zhu
- School of the Environment and Safety Engineering, Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, PR China; State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, PR China; Fujian Key Laboratory of Functional Marine Sensing Materials, Ocean College, Minjiang University, PR China.
| |
Collapse
|
49
|
Electrochemical determination of Pb2+ and Cd2+ with a poly(pyrrole-1-carboxylic acid) modified electrode. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116221] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
50
|
Li J, Bo X. Laser-enabled flexible electrochemical sensor on finger for fast food security detection. JOURNAL OF HAZARDOUS MATERIALS 2022; 423:127014. [PMID: 34461543 DOI: 10.1016/j.jhazmat.2021.127014] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 08/09/2021] [Accepted: 08/20/2021] [Indexed: 06/13/2023]
Abstract
Today's rampant abuse of antibiotics and lean meat powder disturbs environment and threatens public human health. Therefore, fast in-site detection of antibiotics or lean meat powder residue could avoid potential risks. In this work, flexible graphene electrodes (FGE) were easily and facilely patterned and prepared by CO2 laser at room environment, which was coupled with a portable electrochemical analyzer for electronic signal transmission. Laser-enabled flexible electrochemical sensor on finger can be used for rapid real-time in-site electrochemical identification of chloramphenicol (CAP), clenbuterol (CLB) and ractopamine (RAC) in meat. The electrochemical response of CAP, CLB and RAC is investigated with the limit of detection of 2.70, 1.29 and 7.81 μM and the linear range of 10-200, 5-80 and 25-250 μM in phosphate buffer saline (PBS) pH 7.0, correspondingly. The minimum detection concentrations of CAP, CLB and RAC were 20, 10 and 30 μM, respectively, in actual samples of pork. And the minimum detection concentrations of CAP, CLB and RAC were 10, 5 and 25 μM in milk, respectively. Such an integrated sensing platform enriches application of sensors on finger in food security and provides information that prevents drug containments from entering food chain.
Collapse
Affiliation(s)
- Jiajia Li
- Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Faculty of Chemistry, Northeast Normal University, Changchun 130024, PR China
| | - Xiangjie Bo
- Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Faculty of Chemistry, Northeast Normal University, Changchun 130024, PR China.
| |
Collapse
|