1
|
Peterka O, Wolrab D, Jirásko R, Kanásová M, Dolečková Z, Holčapek M. Ultrahigh-Performance Supercritical Fluid Chromatography-Mass Spectrometry in the Clinical Lipidomic Analysis. Methods Mol Biol 2025; 2855:305-314. [PMID: 39354315 DOI: 10.1007/978-1-0716-4116-3_18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/03/2024]
Abstract
Ultrahigh-performance supercritical fluid chromatography-mass spectrometry (UHPSFC/MS) method is optimized for the high-throughput quantitation of lipids in human serum and plasma with an emphasis on robustness and accurate quantitation. Bridged ethylene hybrid (BEH) silica column (100 × 3 mm; 1.7 μm) is used for the separation of 17 nonpolar and polar lipid classes in 4.4 min using the positive ion electrospray ionization mode. The lipid class separation approach in UHPSFC/MS results in the coelution of all lipid species within one lipid class in one chromatographic peak, including two exogenous internal standards (IS) per lipid class, which provides the optimal conditions for robust quantitation. The method was validated according to European Medicines Agency and Food and Drug Administration recommendations. UHPSFC/MS combined with LipidQuant software allows a semiautomated process to determine lipid concentrations with a total run time of only 8 min including column equilibration, which enables the analysis of 160 samples per day.
Collapse
Affiliation(s)
- Ondřej Peterka
- Department of Analytical Chemistry, University of Pardubice, Faculty of Chemical Technology, Pardubice, Czech Republic
- Lipidica, a.s, Pardubice, Czech Republic
| | - Denise Wolrab
- Department of Analytical Chemistry, University of Pardubice, Faculty of Chemical Technology, Pardubice, Czech Republic
| | - Robert Jirásko
- Department of Analytical Chemistry, University of Pardubice, Faculty of Chemical Technology, Pardubice, Czech Republic
| | | | | | - Michal Holčapek
- Department of Analytical Chemistry, University of Pardubice, Faculty of Chemical Technology, Pardubice, Czech Republic.
| |
Collapse
|
2
|
Pilařová V, Plachká K, Svec F, Nováková L. Matrix effects in ultra-high performance supercritical fluid chromatography-mass spectrometry analysis of vitamin E in plasma: The effect of sample preparation and data processing. Talanta 2024; 280:126658. [PMID: 39137659 DOI: 10.1016/j.talanta.2024.126658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 07/29/2024] [Accepted: 07/31/2024] [Indexed: 08/15/2024]
Abstract
The approaches to matrix effects determination and reduction in ultra-high performance supercritical fluid chromatography with mass spectrometry detection have been evaluated in this study using different sample preparation methods and investigation of different calibration models. Five sample preparation methods, including protein precipitation, liquid-liquid extraction, supported liquid extraction, and solid phase extraction based on both "bind and elute" and "interferent removal" modes, were optimized with an emphasis on the matrix effects and recovery of 8 forms of vitamin E, including α-, β-, γ-, and δ-tocopherols and tocotrienols, from plasma. The matrix effect evaluation included the use and comparison of external and internal calibration using three models, i.e., least square with no transformation and no weighting (1/x0), with 1/x2 weighting, and with logarithmic transformation. The calibration model with logarithmic transformation provided the lowest %-errors and the best fits. Moreover, the type of the calibration model significantly affected not only the fit of the data but also the matrix effects when evaluating them based on the comparison of calibration curve slopes. Indeed, based on the used calibration model, the matrix effects calculated from calibration slopes ranged from +92% to - 72% for α-tocopherol and from -77% to +19% in the case of δ-tocotrienol. Thus, it was crucial to calculate the matrix effect by Matuszewski's post-extraction approach at six concentration levels. Indeed, a strong concentration dependence was observed for all optimized sample preparation methods, even if the stable isotopically labelled internal standards (SIL-IS) were used for compensation. The significant differences between individual concentration levels and compounds were observed, even when the tested calibration range covered only one order of magnitude. In methods with wider calibration ranges, the inappropriate use of calibration slope comparison instead of the post-extraction addition approach could result in false negative results of matrix effects. In the selected example of vitamin E, solid-phase extraction was the least affected by matrix effects when used in interferent removal mode, but supported liquid extraction resulted in the highest recoveries. We showed that the calibration model, the use of a SIL-IS, and the analyte concentration level played a crucial role in the matrix effects. Moreover, the matrix effects can significantly differ for compounds with similar physicochemical properties and close retention times. Thus, in all bioanalytical applications, where different analytes are typically determined in one analytical run, it is necessary to carefully select the data processing in addition to the method for the sample preparation, SIL-IS, and chromatography.
Collapse
Affiliation(s)
- Veronika Pilařová
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203, 500 03, Hradec Králové, Czech Republic
| | - Kateřina Plachká
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203, 500 03, Hradec Králové, Czech Republic
| | - Frantisek Svec
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203, 500 03, Hradec Králové, Czech Republic
| | - Lucie Nováková
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203, 500 03, Hradec Králové, Czech Republic.
| |
Collapse
|
3
|
Toribio L, Martín MT, Bernal J. Supercritical Fluid Chromatography in Bioanalysis-A Review. J Sep Sci 2024; 47:e70003. [PMID: 39487700 DOI: 10.1002/jssc.70003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2024] [Revised: 10/02/2024] [Accepted: 10/08/2024] [Indexed: 11/04/2024]
Abstract
In the last decade, the instrumentation improvements in supercritical fluid chromatography (SFC) and the hyphenation to mass spectrometry (MS), have increased the SFC acceptance between scientists, becoming today a valuable tool in analytical chemistry. The unique selectivity, short analysis times, low consumption of organic solvents, and the greener mobile phase, have contributed to expanding its applicability which has led to an increase in the number of publications especially in the bioanalysis area. This work reviews the advantages and main applications of SFC in bioanalysis during the last 5 years. Fundamental aspects concerning mobile phase composition, stationary phase, hyphenation to MS as well as matrix effect have been discussed. Finally, the most relevant applications have been summarized.
Collapse
Affiliation(s)
- Laura Toribio
- Department of Analytical Chemistry, Faculty of Sciences, I. U. CINQUIMA, Analytical Chemistry Group (TESEA), University of Valladolid, Valladolid, Spain
| | - María Teresa Martín
- Department of Analytical Chemistry, Faculty of Sciences, I. U. CINQUIMA, Analytical Chemistry Group (TESEA), University of Valladolid, Valladolid, Spain
| | - José Bernal
- Department of Analytical Chemistry, Faculty of Sciences, I. U. CINQUIMA, Analytical Chemistry Group (TESEA), University of Valladolid, Valladolid, Spain
| |
Collapse
|
4
|
Bhakta N, Kaplitz AS, Black D, Schug KA. Characterization of a Soft Ionization by Chemical Reaction in Transfer Ion Source Hyphenated With Supercritical Fluid Chromatography-Tandem Mass Spectrometry. J Sep Sci 2024; 47:e202400500. [PMID: 39319578 DOI: 10.1002/jssc.202400500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2024] [Revised: 08/27/2024] [Accepted: 08/29/2024] [Indexed: 09/26/2024]
Abstract
A commercially available dielectric barrier discharge ionization (DBDI) source was tested with supercritical fluid chromatography-mass spectrometry (SFC-MS). The compound mixture investigated comprised caffeine, theobromine, theophylline, uracil, testosterone, and pyrene, diluted in methanol. Dynamic response ranges were evaluated with multiple injections at different concentrations. Precision studies demonstrated the robustness and sensitivity of the ionization source across a concentration range of 10-1000 ng/mL. Results from this experiment showed linear regression of 0.99 or greater for all analytes tested over the range with a relative standard deviation (RSD) of less than 10% down to 10 ng/mL for all analytes except theobromine, which had an RSD of less than 10% down to 25 ng/mL. Notably, this study marks the first investigation of sensitivity for coupling a commercial DBDI source with SFC; a limit of detection less than 1 ng/mL was achieved for all compounds. This study demonstrates chromatographic separation by SFC and MS analysis for compounds that ionize poorly using traditional atmospheric pressure ionization, such as polycyclic aromatic hydrocarbons. Combining SFC with the DBDI source opens promising avenues for analyzing compounds that were previously challenging to characterize with standard atmospheric pressure ionization techniques.
Collapse
Affiliation(s)
- Niray Bhakta
- Department of Chemistry and Biochemistry, The University of Texas at Arlington, Arlington, Texas, USA
| | - Alexander S Kaplitz
- Department of Chemistry and Biochemistry, The University of Texas at Arlington, Arlington, Texas, USA
| | - Destini Black
- Department of Chemistry and Biochemistry, The University of Texas at Arlington, Arlington, Texas, USA
| | - Kevin A Schug
- Department of Chemistry and Biochemistry, The University of Texas at Arlington, Arlington, Texas, USA
| |
Collapse
|
5
|
Chen L, Cui Y, Dean B, Liang X. Matrix effect in bioanalytical assay development using supercritical fluid chromatography-mass spectrometry. Biomed Chromatogr 2024; 38:e5759. [PMID: 37845809 DOI: 10.1002/bmc.5759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 09/21/2023] [Accepted: 09/27/2023] [Indexed: 10/18/2023]
Abstract
Matrix effect (ME) is commonly caused by coelution of compounds with target analytes, resulting in either suppression or enhancement of analyte ionization. Thus, to achieve the desired accuracy, precision, and sensitivity, ME needs to be evaluated and controlled during bioanalytical method development. As the application of supercritical fluid chromatography-mass spectrometry (SFC-MS) for analysis of biological samples has increased, ME using SFC-MS has also been investigated with a focus on the difference in ME in SFC-MS compared to other chromatographic techniques used for achiral separation in biological samples. Here, we provide a summary of the status of ME evaluation and mitigation in SFC-MS methods. This review presents an overview of the phenomenon of ME and methods for evaluating ME in bioanalysis. Next, the factors that can impact ME in SFC-MS-based bioanalytical methods are discussed in detail with an emphasis on SFC. A literature review of the evaluation of ME in targeted bioanalytical methods using SFC-MS is included at the end. Robust instrumentation, effective sample preparation, and superb separation selectivity are the foundations of reliable analytical methods as well as the ability to mitigate detrimental ME in SFC-MS methods.
Collapse
Affiliation(s)
- Liuxi Chen
- Drug Metabolism and Pharmacokinetics, Genentech Inc, South San Francisco, California, USA
| | - Yuxiang Cui
- Drug Metabolism and Pharmacokinetics, Genentech Inc, South San Francisco, California, USA
| | - Brian Dean
- Drug Metabolism and Pharmacokinetics, Genentech Inc, South San Francisco, California, USA
| | - Xiaorong Liang
- Drug Metabolism and Pharmacokinetics, Genentech Inc, South San Francisco, California, USA
| |
Collapse
|
6
|
Thoben C, Schlottmann F, Kobelt T, Nitschke A, Gloeden GL, Naylor CN, Kirk AT, Zimmermann S. Ultra-Fast Ion Mobility Spectrometer for High-Throughput Chromatography. Anal Chem 2023; 95:17073-17081. [PMID: 37953497 PMCID: PMC10666085 DOI: 10.1021/acs.analchem.3c03935] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 10/26/2023] [Accepted: 10/30/2023] [Indexed: 11/14/2023]
Abstract
Fast chromatography systems especially developed for high sample throughput applications require sensitive detectors with a high repetition rate. These high throughput techniques, including various chip-based microfluidic designs, often benefit from detectors providing subsequent separation in another dimension, such as mass spectrometry or ion mobility spectrometry (IMS), giving additional information about the analytes or monitoring reaction kinetics. However, subsequent separation is required at a high repetition rate. Here, we therefore present an ultra-fast drift tube IMS operating at ambient pressure. Short drift times while maintaining high resolving power are reached by several key instrumental design features: short length of the drift tube, resistor network of the drift tube, tristate ion shutter, and improved data acquisition electronics. With these design improvements, even slow ions with a reduced mobility of just 0.94 cm2/(V s) have a drift time below 1.6 ms. Such short drift times allow for a significantly increased repetition rate of 600 Hz compared with previously reported values. To further reduce drift times and thus increase the repetition rate, helium can be used as the drift gas, which allows repetition rates of up to 2 kHz. Finally, these significant improvements enable IMS to be used as a detector following ultra-fast separation including chip-based chromatographic systems or droplet microfluidic applications requiring high repetition rates.
Collapse
Affiliation(s)
- Christian Thoben
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Florian Schlottmann
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Tim Kobelt
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Alexander Nitschke
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Gian-Luca Gloeden
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Cameron N. Naylor
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Ansgar T. Kirk
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| |
Collapse
|
7
|
Fu Q, Dong W, Ge D, Ke Y, Jin Y. Supercritical fluid-based method for selective extraction and analysis of indole alkaloids from Uncaria rhynchophylla. J Chromatogr A 2023; 1710:464410. [PMID: 37776825 DOI: 10.1016/j.chroma.2023.464410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 09/02/2023] [Accepted: 09/21/2023] [Indexed: 10/02/2023]
Abstract
The development of an approach based on simultaneous supercritical fluid extraction-sample cleanup, followed by supercritical fluid chromatography/tandem mass spectrometry (SFE-SFC-MS/MS) was as a tool for the extraction, separation and characterization of indole alkaloids of Uncaria rhynchophylla. A two-step SFE method was designed. A mixture of the U. rhynchophylla sample and an adsorbent named C18SCX with the ratio of 1:1 (w/w) was placed into an extraction cell. The extraction temperature was 40 °C and the pressure was 25 Mpa. In the first step, 10 % EtOH as the co-solvent was used to extract for 60 min, which was considered as a cleanup process to remove non-alkaloid components. In the second step, 0.1 % DEA was added to 10 % EtOH and it extracted for 60 min to obtain the desired extract. By introducing an additional adsorbent, the specificity of SFE towards alkaloids was greatly improved. An SFC-MS/MS method was then utilized for analysis of the SFE extract. Using 2-EP as stationary phase with the gradient elution of 0-10 min, 5-25 % EtOH (+0.05 % DEA) in CO2, column temperature 40 °C, and back pressure 13.8 Mpa, 10 peaks were separated within 8 min. Further MS/MS analysis confirmed that nine of the 10 peaks in the SFE extract were indole alkaloids. This study developed a supercritical fluid-based method specifically towards extraction and analysis of alkaloids, which is helpful to the study of alkaline compounds in complex samples.
Collapse
Affiliation(s)
- Qing Fu
- Engineering Research Center of Pharmaceutical Process Chemistry, Ministry of Education, School of Pharmacy, East China University of Science and Technology, Shanghai 200237, PR China
| | - Wenwen Dong
- Engineering Research Center of Pharmaceutical Process Chemistry, Ministry of Education, School of Pharmacy, East China University of Science and Technology, Shanghai 200237, PR China
| | - Dandan Ge
- Engineering Research Center of Pharmaceutical Process Chemistry, Ministry of Education, School of Pharmacy, East China University of Science and Technology, Shanghai 200237, PR China
| | - Yanxiong Ke
- Engineering Research Center of Pharmaceutical Process Chemistry, Ministry of Education, School of Pharmacy, East China University of Science and Technology, Shanghai 200237, PR China
| | - Yu Jin
- Engineering Research Center of Pharmaceutical Process Chemistry, Ministry of Education, School of Pharmacy, East China University of Science and Technology, Shanghai 200237, PR China.
| |
Collapse
|
8
|
Mirveis Z, Howe O, Cahill P, Patil N, Byrne HJ. Monitoring and modelling the glutamine metabolic pathway: a review and future perspectives. Metabolomics 2023; 19:67. [PMID: 37482587 PMCID: PMC10363518 DOI: 10.1007/s11306-023-02031-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 07/03/2023] [Indexed: 07/25/2023]
Abstract
BACKGROUND Analysis of the glutamine metabolic pathway has taken a special place in metabolomics research in recent years, given its important role in cell biosynthesis and bioenergetics across several disorders, especially in cancer cell survival. The science of metabolomics addresses the intricate intracellular metabolic network by exploring and understanding how cells function and respond to external or internal perturbations to identify potential therapeutic targets. However, despite recent advances in metabolomics, monitoring the kinetics of a metabolic pathway in a living cell in situ, real-time and holistically remains a significant challenge. AIM This review paper explores the range of analytical approaches for monitoring metabolic pathways, as well as physicochemical modeling techniques, with a focus on glutamine metabolism. We discuss the advantages and disadvantages of each method and explore the potential of label-free Raman microspectroscopy, in conjunction with kinetic modeling, to enable real-time and in situ monitoring of the cellular kinetics of the glutamine metabolic pathway. KEY SCIENTIFIC CONCEPTS Given its important role in cell metabolism, the ability to monitor and model the glutamine metabolic pathways are highlighted. Novel, label free approaches have the potential to revolutionise metabolic biosensing, laying the foundation for a new paradigm in metabolomics research and addressing the challenges in monitoring metabolic pathways in living cells.
Collapse
Affiliation(s)
- Zohreh Mirveis
- FOCAS Research Institute, Technological University Dublin, City Campus, Camden Row, Dublin 8, Ireland.
- School of Physics and Optometric & Clinical Sciences, Technological University Dublin, City Campus, Grangegorman, Dublin 7, Ireland.
| | - Orla Howe
- School of Biological, Health and Sport Sciences, Technological University Dublin, City Campus, Grangegorman, Dublin 7, Ireland
| | - Paul Cahill
- School of Biotechnology, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Nitin Patil
- FOCAS Research Institute, Technological University Dublin, City Campus, Camden Row, Dublin 8, Ireland
- School of Physics and Optometric & Clinical Sciences, Technological University Dublin, City Campus, Grangegorman, Dublin 7, Ireland
| | - Hugh J Byrne
- FOCAS Research Institute, Technological University Dublin, City Campus, Camden Row, Dublin 8, Ireland
| |
Collapse
|
9
|
Stereoselective analysis of chiral succinate dehydrogenase inhibitors (SDHIs) in foods of plant origin and animal origin by supercritical fluid chromatography-tandem mass spectrometry (SFC-MS/MS). Food Chem 2023; 411:135452. [PMID: 36682161 DOI: 10.1016/j.foodchem.2023.135452] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 12/22/2022] [Accepted: 01/07/2023] [Indexed: 01/11/2023]
Abstract
The stereoisomers of chiral SDHIs were prepared using Autoprep HPLC and chiral columns. The method of combining theoretical calculation with experimental determination was used to confirm the absolute configuration of stereoisomer. SFC-MS/MS and four kinds of chiral columns were used to separate the eight chiral SDHIs, and they could be separated simultaneously using OD-3 column in 6.5 min. The integrated QuEChERS strategy was used to analyse the chiral SDHIs in foods of plant and animal origin, and the average recoveries ranged from 71 % to 119 % with RSD ≤ 18 %, and the LOQ was 1 ng/g. There were 99.2 % and 63.6 % matrix effects were in the range of 0.8-1.2 in foods of plant and animal origin, respectively, showing weak matrix effects. The study provided methods for monitoring chiral SDHIs stereoisomers residues, which were crucial for stereoselective evaluations and improving risk assessments.
Collapse
|
10
|
Si-Hung L, Izumi Y, Bamba T. First proof-of-concept of UC/HILIC for extending the versatility of the current art of supercritical fluid separation. Anal Chim Acta 2023; 1240:340741. [PMID: 36641155 DOI: 10.1016/j.aca.2022.340741] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Revised: 12/04/2022] [Accepted: 12/21/2022] [Indexed: 12/24/2022]
Abstract
Supercritical Fluid Chromatography (SFC), a high-throughput separation technique, has been widely applied as a promising routine method in pharmaceutical, pesticides, and metabolome analysis in the same way as conventional liquid chromatography and gas chromatography. Unified chromatography (UC), an advanced version of SFC, which applied gradient elution with mobile phase changing continuously from supercritical to subcritical and to liquid states, can further extend the SFC applications. UC mostly applying the popular mobile phase of 95%:5%/Methanol:Water with additives allows to analyze many hydrophilic compounds. However, many of phosphorylated metabolites or multi carboxylic acids show very poor peak shapes or even can't be eluted under UC conditions, thus hampering the UC's metabolome coverage. In this study, we proposed the first proof-of-concept of UC/HILIC, a novel strategy to extend the current UC metabolome coverage by employing an aqueous gradient right after the UC gradient on a single packed column in a single measurement. The proposed method showed significant improvement regarding the chromatographic performance and metabolome coverage, while still maintaining the precision and high throughput in comparison with conventional UC methods.
Collapse
Affiliation(s)
- Le Si-Hung
- Division of Metabolomics/Mass Spectrometry Center, Medical Research Center for High Depth Omics, Medical Institute of Bioregulation, Kyushu University, Japan
| | - Yoshihiro Izumi
- Division of Metabolomics/Mass Spectrometry Center, Medical Research Center for High Depth Omics, Medical Institute of Bioregulation, Kyushu University, Japan
| | - Takeshi Bamba
- Division of Metabolomics/Mass Spectrometry Center, Medical Research Center for High Depth Omics, Medical Institute of Bioregulation, Kyushu University, Japan.
| |
Collapse
|
11
|
Yamamoto K, Machida K, Kotani A, Hakamata H. Gradient elution of hydroxyacetophenones by supercritical fluid chromatography with electrochemical detection. ANAL SCI 2022; 39:761-765. [PMID: 36576650 DOI: 10.1007/s44211-022-00248-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Accepted: 12/13/2022] [Indexed: 12/29/2022]
Abstract
Linear gradient elution supercritical fluid chromatography with electrochemical detection was developed using hydroxyacetophenones as analytes. Separation was carried out with a diol column (4.6 mm id × 250 mm length, 5 μm) as a stationary phase and a mixture of supercritical carbon dioxide and methanol as a mobile phase, where the ratio of carbon dioxide and methanol was changed from 99:1 (v/v) to 60:40 (v/v). For the electrochemical detection, methanol containing 1.0 mol L-1 ammonium acetate was used as a supporting electrolyte solution and + 1.2 V was applied to the electrochemical cell. We compared the performance of the present method to isocratic elution supercritical fluid chromatography, and the repeatability, linearity, and detection capability all showed better analytical parameters in the gradient elution. As such, we found that gradient elution supercritical fluid chromatography can achieve the faster separation and save resources compared to isocratic elution. Thus, the present method may contribute to the development of green analytical methods.
Collapse
Affiliation(s)
- Kazuhiro Yamamoto
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences, 1432-1 Horinouchi, Hachioji, Tokyo, 192-0392, Japan
| | - Koichi Machida
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences, 1432-1 Horinouchi, Hachioji, Tokyo, 192-0392, Japan
| | - Akira Kotani
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences, 1432-1 Horinouchi, Hachioji, Tokyo, 192-0392, Japan
| | - Hideki Hakamata
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences, 1432-1 Horinouchi, Hachioji, Tokyo, 192-0392, Japan.
| |
Collapse
|
12
|
Dispas A, Sacré PY, Ziemons E, Hubert P. Emerging analytical techniques for pharmaceutical quality control: Where are we in 2022? J Pharm Biomed Anal 2022; 221:115071. [PMID: 36179505 DOI: 10.1016/j.jpba.2022.115071] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 09/05/2022] [Accepted: 09/20/2022] [Indexed: 12/19/2022]
Abstract
Quality control is a fundamental and critical activity in the pharmaceutical industry that guarantees the quality of medicines. QC analyses are currently performed using several well-known techniques, mainly liquid and gas chromatography. However, current trends are focused on the development of new techniques to reduce analysis time and cost, to improve the performances and decrease ecological footprint. In this context, analytical scientists developed and studied emerging technologies based on spectroscopy and chromatography. The present review aims to give an overview of the recent development of vibrational spectroscopy, supercritical fluid chromatography and multi-dimensional chromatography. Selected emerging techniques are discussed using SWOT analysis and published pharmaceutical QC applications are discussed.
Collapse
Affiliation(s)
- Amandine Dispas
- University of Liege (ULiege), CIRM, Laboratory of Pharmaceutical Analytical Chemistry, Liège, Belgium; University of Liege (ULiege), CIRM, Laboratory for the Analysis of Medicines, Liège, Belgium.
| | - Pierre-Yves Sacré
- University of Liege (ULiege), CIRM, Laboratory of Pharmaceutical Analytical Chemistry, Liège, Belgium
| | - Eric Ziemons
- University of Liege (ULiege), CIRM, Laboratory of Pharmaceutical Analytical Chemistry, Liège, Belgium
| | - Philippe Hubert
- University of Liege (ULiege), CIRM, Laboratory of Pharmaceutical Analytical Chemistry, Liège, Belgium
| |
Collapse
|
13
|
Pilařová V, Hadysová Z, Švec F, Nováková L. Supercritical fluids in analysis of cannabinoids in various Cannabis products. Anal Chim Acta 2022; 1232:340452. [DOI: 10.1016/j.aca.2022.340452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Revised: 09/23/2022] [Accepted: 09/25/2022] [Indexed: 11/01/2022]
|
14
|
Di S, Zhao H, Liu Z, Wang Z, Qi P, Xu H, Wang X. Evaluation of Chiral Fungicide Penflufen in Legume Vegetables: Enantioseparation and Its Mechanism, Enantioselective Behaviors, and Risk Assessment. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2022; 70:9319-9326. [PMID: 35877982 DOI: 10.1021/acs.jafc.2c02238] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Illustrating the enantioselective behaviors of the novel chiral fungicide penflufen was extremely important for ecological safety and human health. For penflufen enantiomers, an excellent separation method including a short analysis time (4 min), a high sensitivity (2 ng/g), and lesser consumption of an organic solvent was first established through supercritical fluid chromatography-tandem mass spectrometry. The enantioseparation mechanism was explained by computational chemistry, and the stronger binding ability of S-(+)-penflufen with cellulose tris-(3-chloro-4-methylphenylcarbamate) (the chiral stationary phase OZ-3 column) contributed to the posterior elution. In legume vegetables, penflufen dissipation was the fastest in Pisum sativum Linn plants (half-life, 1 day) and the slowest in Glycine max plants (half-lives, 11.3-12.9 days). After 30, 50, and 40 days, the rac-penflufen residues were lower than the maximum residue level value in the Electronic Code of Federal Regulations (10 ng/g) in G. max, P. sativum Linn, and Vigna unguiculata, respectively. Abundant S-(+)-penflufen was found in these plants with stereoisomeric excess (se) changes being >10% in the initial stage, so the risk assessment might be driven by S-(+)-penflufen. However, the se changes were <10% in V. unguiculata plants, and the risk assessment might be calculated based on rac-penflufen. Moreover, penflufen enantiomers could be transferred from legume vegetables to soils, and the concentrations increased with time. The high persistence and medium mobility of penflufen in soils might lead to potential groundwater contamination, which was noteworthy. These results could contribute to a more accurate risk assessment of penflufen in legume vegetables.
Collapse
Affiliation(s)
- Shanshan Di
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Agro-product Safety and Nutrition, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
- Agricultural Ministry Key Laboratory for Pesticide Residue Detection, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| | - Huiyu Zhao
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Agro-product Safety and Nutrition, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
- Agricultural Ministry Key Laboratory for Pesticide Residue Detection, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| | - Zhenzhen Liu
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Agro-product Safety and Nutrition, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
- Agricultural Ministry Key Laboratory for Pesticide Residue Detection, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| | - Zhiwei Wang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Agro-product Safety and Nutrition, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
- Agricultural Ministry Key Laboratory for Pesticide Residue Detection, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| | - Peipei Qi
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Agro-product Safety and Nutrition, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
- Agricultural Ministry Key Laboratory for Pesticide Residue Detection, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| | - Hao Xu
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Agro-product Safety and Nutrition, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
- Agricultural Ministry Key Laboratory for Pesticide Residue Detection, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| | - Xinquan Wang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Agro-product Safety and Nutrition, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
- Agricultural Ministry Key Laboratory for Pesticide Residue Detection, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| |
Collapse
|
15
|
Roy D, Tarafder A, Miller L. Additives in chiral packed column super/subcritical fluid chromatography: A little goes a long way. J Chromatogr A 2022; 1676:463216. [DOI: 10.1016/j.chroma.2022.463216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 06/08/2022] [Accepted: 06/10/2022] [Indexed: 10/18/2022]
|
16
|
Shah PA, Shrivastav PS, Sharma VS. Supercritical fluid chromatography for the analysis of antihypertensive Drugs: A short review. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
17
|
Separation and Determination of Fluindapyr Enantiomers in Cucumber and Tomato and by Supercritical Fluid Chromatography Tandem Mass Spectrometry. Food Chem 2022; 395:133571. [DOI: 10.1016/j.foodchem.2022.133571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Revised: 06/12/2022] [Accepted: 06/22/2022] [Indexed: 11/22/2022]
|
18
|
Supercritical fluid chromatography time-of-flight mass spectrometry enantiomeric determination of basic drugs in sewage samples. J Chromatogr A 2022; 1673:463088. [DOI: 10.1016/j.chroma.2022.463088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 04/21/2022] [Accepted: 04/23/2022] [Indexed: 11/17/2022]
|
19
|
Deidda R, Losacco GL, Schelling C, Regalado EL, Veuthey JL, Guillarme D. Sub/supercritical fluid chromatography versus liquid chromatography for peptide analysis. J Chromatogr A 2022; 1676:463282. [DOI: 10.1016/j.chroma.2022.463282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 06/22/2022] [Accepted: 06/24/2022] [Indexed: 10/17/2022]
|
20
|
Yang F, Dong H, Zhang F, Shao J, Wang Y, Deng H, Tang G, Zhang X, Li B, Liu S. A rapid and environmentally friendly method for determination of parabens preservatives in flavors by supercritical fluid chromatography tandem mass spectrometry. J Sep Sci 2022; 45:3043-3053. [PMID: 35621260 DOI: 10.1002/jssc.202200241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Revised: 05/07/2022] [Accepted: 05/23/2022] [Indexed: 11/09/2022]
Abstract
A rapid method for determination of parabens preservatives (methyl paraben, ethyl paraben, isopropyl paraben, propyl paraben, isobutyl paraben, and butyl paraben) in flavors was established by using supercritical fluid chromatography tandem mass spectrometry combined with dispersive solid phase extraction. After adding methanol and primary secondary amine to the sample simultaneously, high extraction efficiency and good sample cleanup could be obtained by simple shaking. Parabens were well separated on a Chiralpak IG-3 column in 6 min by gradient elution. Recoveries from spiked blank samples at 0.5, 1.0, and 5.0 mg/kg were determined to be 88.3-106.6%with relative standard deviations less than 8.0%. All analytes achieved good linear relation (r≥0.999 2). The limits of detection for all analytes ranged from 0.03 to 0.09 mg/kg and the limits of quantification from 0.11 to 0.31 mg/kg, respectively. A total of 20 actual samples were successfully analyzed by taking the proposed method. Being simple, rapid, green and reliable, this method can be taken for the determination of parabens preservatives in flavors. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Fei Yang
- China National Tobacco Quality Supervision and Test Center, Zhengzhou, 450001, China
| | - Hao Dong
- China National Tobacco Quality Supervision and Test Center, Zhengzhou, 450001, China
| | - Fengmei Zhang
- China tobacco Yunnan Industrial Co. Ltd, Kunming, 650231, China
| | - Jimin Shao
- Sichuan Tobacco Quality Supervision and Testing Station, Chengdu, 610041, China
| | - Ying Wang
- China National Tobacco Quality Supervision and Test Center, Zhengzhou, 450001, China
| | - Huimin Deng
- China National Tobacco Quality Supervision and Test Center, Zhengzhou, 450001, China
| | - Gangling Tang
- China National Tobacco Quality Supervision and Test Center, Zhengzhou, 450001, China
| | - Xiaotao Zhang
- China tobacco Guizhou Industrial Co. Ltd, Guiyang, 550009, China
| | - Bo Li
- Guangdong Tobacco Quality Supervision and Testing Station, Guangzhou, 510610, China
| | - Shanshan Liu
- China National Tobacco Quality Supervision and Test Center, Zhengzhou, 450001, China
| |
Collapse
|
21
|
Deidda R, Dispas A, De Bleye C, Hubert P, Ziemons É. Critical review on recent trends in cannabinoid determination on cannabis herbal samples: From chromatographic to vibrational spectroscopic techniques. Anal Chim Acta 2022; 1209:339184. [DOI: 10.1016/j.aca.2021.339184] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 10/14/2021] [Accepted: 10/16/2021] [Indexed: 12/13/2022]
|
22
|
Yamamoto K, Nishimura T, Machida K, Kotani A, Hakamata H. Supercritical fluid chromatography with post-column addition of supporting electrolyte solution for electrochemical determination of tocopherol and tocotrienol isomers. J Sep Sci 2022; 45:1797-1805. [PMID: 35247931 DOI: 10.1002/jssc.202100923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 03/02/2022] [Accepted: 03/02/2022] [Indexed: 11/06/2022]
Abstract
A supercritical fluid chromatography with electrochemical detection system was developed for the simultaneous determination of tocopherol and tocotrienol isomers. The supercritical fluid chromatography with electrochemical detection system was connected with an additional pump to create a flow path to add a supporting electrolyte solution. The supporting electrolyte solution was mixed with a mobile phase in a post-column fashion, enabling the independent control of the separation and detection. After optimization of the measurement conditions, vitamin E isomers and an internal standard substance (2,2,5,7,8-pentamethyl-6-hydroxychroman) were separated within 30 min using a mixture of supercritical carbon dioxide and methanol (99:1, v/v) as a mobile phase and a cyanopropyl column (4.6 mm inner diameter × 250 mm length, 5 μm). For the electrochemical detection, methanol containing 1.0 mol/L ammonium acetate was used as a supporting electrolyte solution and the applied potential was set at +0.8 V. This analytical method showed good linearity (5 to 100 μg/mL) and repeatability (less than 2.5% relative standard deviation (n = 6)) and was applicable to the determination of tocopherol and tocotrienol isomers in nutrition supplements. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Kazuhiro Yamamoto
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences, 1432-1 Horinouchi, Hachioji, Tokyo, 192-0392, Japan
| | - Takuma Nishimura
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences, 1432-1 Horinouchi, Hachioji, Tokyo, 192-0392, Japan
| | - Koichi Machida
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences, 1432-1 Horinouchi, Hachioji, Tokyo, 192-0392, Japan
| | - Akira Kotani
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences, 1432-1 Horinouchi, Hachioji, Tokyo, 192-0392, Japan
| | - Hideki Hakamata
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences, 1432-1 Horinouchi, Hachioji, Tokyo, 192-0392, Japan
| |
Collapse
|
23
|
Si-Hung L, Izumi Y, Nakao M, Takahashi M, Bamba T. Investigation of supercritical fluid chromatography retention behaviors using quantitative structure-retention relationships. Anal Chim Acta 2022; 1197:339463. [DOI: 10.1016/j.aca.2022.339463] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 01/02/2022] [Accepted: 01/06/2022] [Indexed: 12/11/2022]
|
24
|
Gazárková T, Plachká K, Svec F, Nováková L. Current state of supercritical fluid chromatography-mass spectrometry. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116544] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
25
|
Application space for SFC in pharmaceutical drug discovery and development. SEP SCI TECHNOL 2022. [DOI: 10.1016/b978-0-323-88487-7.00007-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/05/2022]
|
26
|
Broeckhoven K. Advances in the limits of separation power in supercritical fluid chromatography. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2021.116489] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
27
|
Si-Hung L, Bamba T. Current state and future perspectives of supercritical fluid chromatography. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116550] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
28
|
Beres M. Expanding the boundaries of SFC: Analysis of biomolecules. SEP SCI TECHNOL 2022. [DOI: 10.1016/b978-0-323-88487-7.00011-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/05/2022]
|
29
|
Wolrab D, Peterka O, Chocholoušková M, Holčapek M. Ultrahigh-Performance Supercritical Fluid Chromatography / Mass Spectrometry in the Lipidomic Analysis. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116546] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
30
|
Measurements of drugs and metabolites in biological matrices using SFC and SFE-SFC-MS. SEP SCI TECHNOL 2022. [DOI: 10.1016/b978-0-323-88487-7.00004-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
|
31
|
Jambo H, Hubert P, Dispas A. Supercritical fluid chromatography for pharmaceutical quality control: Current challenges and perspectives. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2021.116486] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
32
|
Teng C, Gu Y, Wang Y, Wang Z, Zhao H, Qi P, Guo C, Xu H, Di S, Wang X. Enantioselective Dissipation, Residue, and Risk Assessment of Diniconazole Enantiomers in Four Kinds of Fruits. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2021; 69:15512-15520. [PMID: 34927422 DOI: 10.1021/acs.jafc.1c03852] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Chiral diniconazole is a widely used triazole fungicide, while its enantioselective behaviors in fruits have not been reported. In this article, the absolute configuration was confirmed. A fast supercritical fluid chromatography-tandem mass spectrometry (SFC-MS/MS) method was developed for the chiral separation and enantioselective study of diniconazole in four kinds of fruits. The residual concentrations gradually decreased with time in four kinds of fruits after applying diniconazole. The dissipation half-lives of R-diniconazole and S-diniconazole were in the range of 5.3-7.9 and 2.5-7.1 days respectively, and S-diniconazole was degraded preferentially. The residue concentrations were lower than the EU's MRL (0.01 mg/kg) on the 40th (harvest time), 30th, and 10th day in pear, jujube, and apple, respectively. But, in peach, residue concentrations were still higher than the MRL after 60 days and the ratio of R/S was 2.2. These results could be helpful for the reasonable use and risk assessment of chiral diniconazole.
Collapse
Affiliation(s)
- Chunhong Teng
- College of Agriculture, Northeast Agricultural University, No. 600 Changjiang Road, Harbin 150030, P. R. China
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Quality and Standard of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| | - Yuanlin Gu
- College of Agriculture, Northeast Agricultural University, No. 600 Changjiang Road, Harbin 150030, P. R. China
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Quality and Standard of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| | - Yanhua Wang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Quality and Standard of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| | - Zhiwei Wang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Quality and Standard of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| | - Huiyu Zhao
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Quality and Standard of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| | - Peipei Qi
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Quality and Standard of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| | - Chao Guo
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Quality and Standard of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
- Institute of Fermentation Engineering, College of Biotechnology and Bioengineering, Zhejiang University of Technology, Hangzhou 310032, P. R. China
| | - Hao Xu
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Quality and Standard of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| | - Shanshan Di
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Quality and Standard of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| | - Xinquan Wang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products/ Key Laboratory of Detection for Pesticide Residues and Control of Zhejiang, Institute of Quality and Standard of Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, P. R. China
| |
Collapse
|
33
|
Yamamoto K, Machida K, Kotani A, Hakamata H. Emerging Separation Techniques in Supercritical Fluid Chromatography. Chem Pharm Bull (Tokyo) 2021; 69:970-975. [PMID: 34602578 DOI: 10.1248/cpb.c21-00306] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Supercritical fluid chromatography (SFC) has unique separative characteristics distinguished from those of HPLC and gas chromatography. At present, SFC is widely used and there are many applications in various biological, medical, and pharmaceutical fields. In this review, we focus on recently developed novel techniques related to SFC separation including: new column stationary phases, microfluidics, two-dimensional separation, and gas-liquid separation. In addition, we discuss the application of SFC using a water-containing modifier to biological molecules such as amino acids, peptides, and small proteins that had been challenging analytes.
Collapse
Affiliation(s)
- Kazuhiro Yamamoto
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences
| | - Koichi Machida
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences
| | - Akira Kotani
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences
| | - Hideki Hakamata
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences
| |
Collapse
|
34
|
Toribio L, Bernal J, Martín MT, Ares AM. Supercritical fluid chromatography coupled to mass spectrometry: A valuable tool in food analysis. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116350] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
35
|
Hofstetter RK, Schulig L, Bethmann J, Grimm M, Sager M, Aude P, Keßler R, Kim S, Weitschies W, Link A. Supercritical fluid extraction-supercritical fluid chromatography of saliva: Single-quadrupole mass spectrometry monitoring of caffeine for gastric emptying studies †. J Sep Sci 2021; 44:3700-3716. [PMID: 34355502 DOI: 10.1002/jssc.202100443] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 08/02/2021] [Accepted: 08/02/2021] [Indexed: 11/06/2022]
Abstract
Saliva is an attractive sampling matrix for measuring various endogenous and exogeneous substances but requires sample treatment prior to chromatographic analysis. Exploiting supercritical CO2 for both extraction and chromatography simplifies sample preparation, reduces organic solvent consumption, and minimizes exposure to potentially infectious samples, but has not yet been applied to oral fluid. Here, we demonstrate the feasibility and benefits of online supercritical fluid extraction coupled to supercritical fluid chromatography and single-quadrupole mass spectrometry for monitoring the model salivary tracer caffeine. A comparison of 13 C- and 32 S-labeled internal standards with external standard calibration confirmed the superiority of stable isotope-labeled caffeine over nonanalogous internal standards. As proof of concept, the validated method was applied to saliva from a magnetic resonance imaging study of gastric emptying. After administration of 35 mg caffeine via ice capsule, salivary levels correlated with magnetic resonance imaging data, corroborating caffeine's usefulness as tracer of gastric emptying (R2 = 0.945). In contrast to off-line methods, online quantification required only minute amounts of organic solvents and a single manual operation prior to online bioanalysis of saliva, thus demonstrating the usefulness of CO2 -based extraction and separation techniques for potentially infective biomatrices.
Collapse
Affiliation(s)
- Robert K Hofstetter
- Pharmaceutical and Medicinal Chemistry, Institute of Pharmacy, University of Greifswald, Greifswald, Germany
| | - Lukas Schulig
- Pharmaceutical and Medicinal Chemistry, Institute of Pharmacy, University of Greifswald, Greifswald, Germany
| | - Jonas Bethmann
- Pharmaceutical and Medicinal Chemistry, Institute of Pharmacy, University of Greifswald, Greifswald, Germany
| | - Michael Grimm
- Department of Biopharmaceutics and Pharmaceutical Technology, Institute of Pharmacy, University of Greifswald, Greifswald, Germany
| | - Maximilian Sager
- Department of Biopharmaceutics and Pharmaceutical Technology, Institute of Pharmacy, University of Greifswald, Greifswald, Germany
| | - Philipp Aude
- Department of Biopharmaceutics and Pharmaceutical Technology, Institute of Pharmacy, University of Greifswald, Greifswald, Germany
| | - Rebecca Keßler
- Department of Diagnostic Radiology and Neuroradiology, University Hospital Greifswald, Greifswald, Germany
| | - Simon Kim
- Department of Trauma, Reconstructive Surgery and Rehabilitation Medicine, University Medicine Greifswald, Greifswald, Germany.,Leibniz Institute for Plasma Science and Technology (INP Greifswald), Greifswald, Germany
| | - Werner Weitschies
- Department of Biopharmaceutics and Pharmaceutical Technology, Institute of Pharmacy, University of Greifswald, Greifswald, Germany
| | - Andreas Link
- Pharmaceutical and Medicinal Chemistry, Institute of Pharmacy, University of Greifswald, Greifswald, Germany
| |
Collapse
|
36
|
Losacco GL, Veuthey JL, Guillarme D. Metamorphosis of supercritical fluid chromatography: A viable tool for the analysis of polar compounds? Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116304] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
37
|
Mueller F, Losacco GL, Nicoli R, Guillarme D, Thomas A, Grata E. Enantiomeric methadone quantitation on real post-mortem dried matrix spots samples: Comparison of liquid chromatography and supercritical fluid chromatography coupled to mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1177:122755. [PMID: 34107411 DOI: 10.1016/j.jchromb.2021.122755] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Revised: 04/12/2021] [Accepted: 04/30/2021] [Indexed: 11/18/2022]
Abstract
This study describes two bioanalytical methods for the quantitation of the two methadone enantiomers in dried matrix spots using high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) and high performance supercritical chromatography tandem mass spectrometry (HPSFC-MS/MS). Dried matrix spots were obtained by spotting 10 µL of each sample fluid on a Whatman paper. Methadone and its main metabolite, EDDP, were extracted with 100 µL methanol and subsequently injected into the LC-MS/MS and SFC-MS/MS systems. Enantiomeric separation was achieved with AGP-column for the LC conditions and with Chiralpak IH-3 in SFC. The two methods were fully validated and 93 post-mortem samples were analysed with both analytical methods. Results from validation parameters and results obtained for all post-mortem samples were compared with a significant spearman correlation of rs = 0.9978 for R-methadone and rs = 0.9981 for S-methadone. The LC method provided better results in terms of uncertainty, retention factor and resolution, whereas SFC provides better sensitivity, with lower LOD. Median R-/S-methadone ratio in peripheral blood was found equal to 1.60 (N = 32), varying from 0.79 to 4.23. The reported values were in good agreement with previously published results. Based on the results obtained here, SFC-MS/MS can be considered a reliable alternative to the widely used LC-MS/MS for the quantitation of methadone enantiomers in bioanalysis and should be evaluated for other bioanalytical methods. Both methods can be easily and quickly used in toxicological routine analysis for the methadone quantitation in human fluids matrices, even if considering that the polysaccharide coated column IH-3 used in SFC does not allow the enantiomeric EDDP separation.
Collapse
Affiliation(s)
- F Mueller
- Alpine Foundation for Life Sciences (FASV), 6718 Olivone, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211 Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211 Geneva 4, Switzerland.
| | - G L Losacco
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211 Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211 Geneva 4, Switzerland
| | - R Nicoli
- Swiss Laboratory for Doping Analyses, University Center of Legal Medicine, Lausanne & Gevena, Lausanne University Hospital & University of Lausanne, Switzerland
| | - D Guillarme
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211 Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211 Geneva 4, Switzerland
| | - A Thomas
- Unit of Forensic Toxicology and Chemistry, CURML, Lausanne University Hospital-Geneva University Hospitals, Switzerland; Faculty Unit of Toxicology, CURML, Lausanne University Hospital, Faculty of Biology and Medicine, University of Lausanne, Switzerland
| | - E Grata
- Alpine Foundation for Life Sciences (FASV), 6718 Olivone, Switzerland
| |
Collapse
|
38
|
Yang F, Zhang X, Shao J, Xiong W, Ji Y, Liu S, Tang G, Deng H, Wang Y. A rapid method for the simultaneous stereoselective determination of the triazole fungicides in tobacco by supercritical fluid chromatography-tandem mass spectrometry combined with pass-through cleanup. J Chromatogr A 2021; 1642:462040. [PMID: 33721813 DOI: 10.1016/j.chroma.2021.462040] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 02/24/2021] [Accepted: 02/27/2021] [Indexed: 11/19/2022]
Abstract
This work presents a simple, rapid and green chiral analysis method for five triazole fungicides (penconazole, tebuconazole, triadimefon, myclobutanil, and triadimenol) in tobacco, by which the samples were cleaned up by the novel pass-through solid phase extraction and subsequently the stereoisomers were separated and determined by the supercritical fluid chromatography-tandem mass spectrometry (SFC-MS/MS). Optimized separation of the stereoisomers was achieved on an ACQUITY UPC2 Trefoil AMY 1 column within 6 min. Under fortified concentration levels of 0.1, 0.5 and 2.0 mg/kg, the mean recoveries were 82.8-106.6%, the intra-day relative standard deviations (RSDs) were 1.1-6.6%, and the inter-day RSDs were 2.5-5.6%. The correlation coefficient was greater than 0.9926 for all studied analytes within the range of 10-500 ng/mL. The limits of detection (LODs) for all stereoisomers ranged from 0.26 μg/kg to 3.24 μg/kg. The established method was subsequently successfully applied to analyze authentic samples, confirming that this method is a novel, rapid and environmentally friendly method for the stereoselective separation of triazole fungicides in tobacco.
Collapse
Affiliation(s)
- Fei Yang
- China National Tobacco Quality Supervision and Test Center, Zhengzhou 450001, China
| | - Xiaotao Zhang
- China tobacco Guizhou Industrial Co. Ltd, Guiyang 550009, China
| | - Jimin Shao
- Sichuan Tobacco Quality Supervision and Testing Station, Chengdu 610041, China
| | - Wei Xiong
- Sichuan Tobacco Quality Supervision and Testing Station, Chengdu 610041, China
| | - Yuan Ji
- China National Tobacco Quality Supervision and Test Center, Zhengzhou 450001, China
| | - Shanshan Liu
- China National Tobacco Quality Supervision and Test Center, Zhengzhou 450001, China
| | - Gangling Tang
- China National Tobacco Quality Supervision and Test Center, Zhengzhou 450001, China
| | - Huimin Deng
- China National Tobacco Quality Supervision and Test Center, Zhengzhou 450001, China
| | - Ying Wang
- China National Tobacco Quality Supervision and Test Center, Zhengzhou 450001, China.
| |
Collapse
|
39
|
Losacco GL, DaSilva JO, Liu J, Regalado EL, Veuthey JL, Guillarme D. Expanding the range of sub/supercritical fluid chromatography: Advantageous use of methanesulfonic acid in water-rich modifiers for peptide analysis. J Chromatogr A 2021; 1642:462048. [PMID: 33744606 DOI: 10.1016/j.chroma.2021.462048] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Revised: 03/01/2021] [Accepted: 03/02/2021] [Indexed: 11/30/2022]
Abstract
The aim of this work was to expand the applicability range of UHPSFC to series of synthetic and commercialized peptides. Initially, a screening of different column chemistries available for UHPSFC analysis was performed, in combination with additives of either basic or acidic nature. The combination of an acidic additive (13 mM TFA) with a basic stationary phase (Torus DEA and 2-PIC) was found to be the best for a series of six synthetic peptides possessing either acidic, neutral or basic isoelectric points. Secondly, methanesulfonic acid (MSA) was evaluated as a potential replacement for TFA. Due to its stronger acidity, MSA gave better performance than TFA at the same concentration level. Furthermore, the use of reduced percentages of MSA, such as 8 mM, yielded similar results to those observed with 15 mM of MSA. The optimized UHPSFC method was, then, used to compare the performance of UHPSFC against RP-UHPLC for peptides with different pI and with increasing peptide chain length. UHPSFC was found to give a slightly better separation of the peptides according to their pI values, in few cases orthogonal to that observed in UHPLC. On the other hand, UHPSFC produced a much better separation of peptides with an increased amino acidic chain compared to UHPLC. Subsequently, UHPSFC-MS was systematically compared to UHPLC-MS using a set of linear and cyclic peptides commercially available. The optimized UHPSFC method was able to generate at least similar, and in some cases even better performance to UHPLC with the advantage of providing complementary information to that given by UHPLC analysis. Finally, the analytical UHPSFC method was transferred to a semipreparative scale using a proprietary cyclic peptide, demonstrating excellent purity and high yield in less than 15 min.
Collapse
Affiliation(s)
- Gioacchino Luca Losacco
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211 Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211 Geneva 4, Switzerland
| | - Jimmy Oliviera DaSilva
- Analytical Research and Development, MRL, Merck & Co, Inc., 126 E. Lincoln Ave, Rahway, NJ 07065, United States
| | - Jinchu Liu
- Analytical Research and Development, MRL, Merck & Co, Inc., 126 E. Lincoln Ave, Rahway, NJ 07065, United States
| | - Erik L Regalado
- Analytical Research and Development, MRL, Merck & Co, Inc., 126 E. Lincoln Ave, Rahway, NJ 07065, United States
| | - Jean-Luc Veuthey
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211 Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211 Geneva 4, Switzerland
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211 Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211 Geneva 4, Switzerland.
| |
Collapse
|
40
|
Muhammad N, Zia-ul-Haq M, Ali A, Naeem S, Intisar A, Han D, Cui H, Zhu Y, Zhong JL, Rahman A, Wei B. Ion chromatography coupled with fluorescence/UV detector: A comprehensive review of its applications in pesticides and pharmaceutical drug analysis. ARAB J CHEM 2021. [DOI: 10.1016/j.arabjc.2020.102972] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
|
41
|
Vaeli N, Honarvar B, Esfandiari N, Aboosadi ZA. A laboratory study on extracting active ingredients from scrophularia striata boiss using ultrasound-assisted supercritical fluid extraction technique. SOUTH AFRICAN JOURNAL OF CHEMICAL ENGINEERING 2021. [DOI: 10.1016/j.sajce.2020.09.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
|
42
|
Li G, Lv Y, Chen M, Ye X, Niu Z, Bai H, Lei H, Ma Q. Post-Chromatographic Dicationic Ionic Liquid-Based Charge Complexation for Highly Sensitive Analysis of Anionic Compounds by Ultra-High-Performance Supercritical Fluid Chromatography Coupled with Electrospray Ionization Mass Spectrometry. Anal Chem 2020; 93:1771-1778. [PMID: 33382576 DOI: 10.1021/acs.analchem.0c04612] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
A green analytical strategy has been developed for the analysis of 10 perfluorinated compounds (PFCs) incorporating supramolecular solvent (SUPRAS)-based extraction and ultra-high-performance supercritical fluid chromatography (UHPSFC)-tandem mass spectrometry. The SUPRAS was prepared through self-assembly of reverse micelles by mixing heptanol, tetrahydrofuran, and water at optimized volume ratios. An imidazolium-based germinal dicationic ionic liquid (DIL), 1,1-bis(3-methylimidazolium-1-yl) butylene difluoride ([C4(MIM)2]F2), was dissolved in the make-up solvent of UHPSFC and introduced post-column but before the electrospray ionization source. After chromatographic separation on a Torus DIOL analytical column (100 mm × 2.1 mm, 1.7 μm), the PFC analytes associated with the DIL reagent through charge complexation. The formation of positively charged complexes resulted in improved ionization efficiency and analytical sensitivity. Enhancement in signal intensity by one to two magnitudes was achieved in the positive ionization mode compared to the negative ionization mode without using the dicationic ion-pairing reagent. The developed protocol was applied to 32 samples of real textiles and 6 samples of real food packaging materials, which exhibited great potential for the analysis of anionic compounds.
Collapse
Affiliation(s)
- Guoping Li
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China.,School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China
| | - Yueguang Lv
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China.,School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Meng Chen
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Xiwen Ye
- Technology Center of Qingdao Customs District, Qingdao 266002, China
| | - Zengyuan Niu
- Technology Center of Qingdao Customs District, Qingdao 266002, China
| | - Hua Bai
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Haimin Lei
- School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China
| | - Qiang Ma
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| |
Collapse
|
43
|
Application of Chiral and Achiral Supercritical Fluid Chromatography in Pesticide Analysis: A Review. J Chromatogr A 2020; 1634:461684. [DOI: 10.1016/j.chroma.2020.461684] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 10/28/2020] [Accepted: 11/01/2020] [Indexed: 12/13/2022]
|
44
|
Deidda R, Schelling C, Roussel J, Dispas A, De Bleye C, Ziemons É, Hubert P, Veuthey J. The analysis of cannabinoids in cannabis samples by supercritical fluid chromatography and ultra‐high‐performance liquid chromatography: A comparison study. ACTA ACUST UNITED AC 2020. [DOI: 10.1002/ansa.202000091] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Riccardo Deidda
- Laboratory of Pharmaceutical Analytical Chemistry University of Liège (ULiège) CIRM Liège Belgium
| | - Cédric Schelling
- School of Pharmaceutical Sciences University of Geneva Geneva Switzerland
- Institute of Pharmaceutical Sciences of Western Switzerland University of Geneva Geneva Switzerland
| | | | - Amandine Dispas
- Laboratory of Pharmaceutical Analytical Chemistry University of Liège (ULiège) CIRM Liège Belgium
- Laboratory of Medicine Analysis CIRM University of Liège Liège Belgium
| | - Charlotte De Bleye
- Laboratory of Pharmaceutical Analytical Chemistry University of Liège (ULiège) CIRM Liège Belgium
| | - Éric Ziemons
- Laboratory of Pharmaceutical Analytical Chemistry University of Liège (ULiège) CIRM Liège Belgium
| | - Philippe Hubert
- Laboratory of Pharmaceutical Analytical Chemistry University of Liège (ULiège) CIRM Liège Belgium
| | - Jean‐Luc Veuthey
- School of Pharmaceutical Sciences University of Geneva Geneva Switzerland
- Institute of Pharmaceutical Sciences of Western Switzerland University of Geneva Geneva Switzerland
| |
Collapse
|
45
|
van de Velde B, Guillarme D, Kohler I. Supercritical fluid chromatography - Mass spectrometry in metabolomics: Past, present, and future perspectives. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1161:122444. [PMID: 33246285 DOI: 10.1016/j.jchromb.2020.122444] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2020] [Revised: 10/13/2020] [Accepted: 10/15/2020] [Indexed: 12/25/2022]
Abstract
Metabolomics, which consists of the comprehensive analysis of metabolites within a biological system, has been playing a growing role in the implementation of personalized medicine in modern healthcare. A wide range of analytical approaches are used in metabolomics, notably mass spectrometry (MS) combined to liquid chromatography (LC), gas chromatography (GC), or capillary electrophoresis (CE). However, none of these methods enable a comprehensive analysis of the metabolome, due to its extreme complexity and the large differences in physico-chemical properties between metabolite classes. In this context, supercritical fluid chromatography (SFC) represents a promising alternative approach to improve the metabolome coverage, while further increasing the analysis throughput. SFC, which uses supercritical CO2 as mobile phase, leads to numerous advantages such as improved kinetic performance and lower environmental impact. This chromatographic technique has gained a significant interest since the introduction of advanced instrumentation, together with the introduction of dedicated interfaces for hyphenating SFC to MS. Moreover, new developments in SFC column chemistry (including sub-2 µm particles), as well as the use of large amounts of organic modifiers and additives in the CO2-based mobile phase, significantly extended the application range of SFC, enabling the simultaneous analysis of a large diversity of metabolites. Over the last years, several applications have been reported in metabolomics using SFC-MS - from lipophilic compounds, such as steroids and other lipids, to highly polar compounds, such as carbohydrates, amino acids, or nucleosides. With all these advantages, SFC-MS is promised to a bright future in the field of metabolomics.
Collapse
Affiliation(s)
- Bas van de Velde
- VU Amsterdam, Amsterdam Institute of Molecular and Life Sciences (AIMMS), Division of BioAnalytical Chemistry, Amsterdam, the Netherlands; Center for Analytical Sciences Amsterdam, Amsterdam, the Netherlands
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, Switzerland
| | - Isabelle Kohler
- VU Amsterdam, Amsterdam Institute of Molecular and Life Sciences (AIMMS), Division of BioAnalytical Chemistry, Amsterdam, the Netherlands; Center for Analytical Sciences Amsterdam, Amsterdam, the Netherlands.
| |
Collapse
|
46
|
Losacco GL, Fekete S, Veuthey JL, Guillarme D. Investigating the use of unconventional temperatures in supercritical fluid chromatography. Anal Chim Acta 2020; 1134:84-95. [PMID: 33059869 DOI: 10.1016/j.aca.2020.07.076] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 07/28/2020] [Accepted: 07/30/2020] [Indexed: 10/23/2022]
Abstract
The use of unorthodox temperatures, ranging from -5 °C up to 80 °C, have been thoroughly investigated in supercritical fluid chromatography. To this purpose, an initial evaluation of the kinetic and thermodynamic performance has been made with a set of 4 analytes eluting at different percentages of organic co-solvent in the mobile phase (3%-10% - 45%-80%). The van Deemter plots have demonstrated how, at low organic modifier presence, the use of low temperatures did not necessarily translate into worse performance, while high temperatures could pose more issues due to the poor handling of the super/subcritical mobile phase by the chromatographic system. With important percentages of co-solvent, however, high temperatures were fundamental in ensuring better profiles of the van Deemter plots, compared to low temperatures. Pressure plots have demonstrated that gradients reaching elevated percentages of organic modifiers can also be used on stationary phases packed with sub 2 μm silica particles if high temperatures are employed. The thermodynamic evaluation, made via the analysis of van't Hoff plots, indicates the presence of three retention behaviors happening in UHPSFC when switching from high to low temperatures, depending on the co-solvent percentage needed to elute one analyte. Finally, an assessment of the stationary phase stability at high temperatures was performed: the retention times variabilities recorded were minimal (RSD < 2.5%), as well as the peak widths and inlet column pressures were somewhat constant throughout the analyses. In the second part of this study, a focus on potential applications benefiting from such unconventional temperatures has been made. A series of challenging analytes have experienced better chromatographic resolution at either high or low temperatures, providing therefore a potentially interesting tool to analysts during the chromatographic method development process. In conclusion, the UV sensitivity at different temperatures was also taken into consideration, with no significant impact on the quality of the UV signal under any condition.
Collapse
Affiliation(s)
- Gioacchino Luca Losacco
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva 4, Switzerland
| | - Szabolcs Fekete
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva 4, Switzerland
| | - Jean-Luc Veuthey
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva 4, Switzerland
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva 4, Switzerland.
| |
Collapse
|
47
|
A green and efficient pseudotargeted lipidomics method for the study of depression based on ultra-high performance supercritical fluid chromatography-tandem mass spectrometry. J Pharm Biomed Anal 2020; 192:113646. [PMID: 33017797 DOI: 10.1016/j.jpba.2020.113646] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 09/04/2020] [Accepted: 09/15/2020] [Indexed: 12/23/2022]
Abstract
The pseudotargeted lipidomics method integrates the advantages of untargeted andtargeted lipidomics methods as a novel emerging approach. In this study, a green andefficient pseudotargeted lipidomics method based on ultra-high performancesupercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) wasdeveloped. The tandem mass spectra of the analytes were obtained by using UHPSFCwith quadrupole-time of flight MS (Q-TOF MS) in MS E mode and the multiplereaction monitoring (MRM) transitions of the lipidome were defined. Then, thecandidate MRM transitions were verified by UHPSFC with triple quadrupole massspectrometry (QqQ MS) in the scheduled MRM mode. In total, 758 potential lipidscorresponding to 509 and 249 MRM transitions were detected within 8 min in positiveand negative modes, respectively. The established pseudotargeted lipidomics methodwas validated to have excellent analytical characteristics. Compared with thepseudotargeted method based on ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), the UHPSFC-MS/MS-basedpseudotargeted method not only reduced the analytical time by half but also improvedthe sensitivity and resolution for most analytes, especially had better separation forlipid isomers. Besides, the UHPSFC-MS/MS-based pseudotargeted method showedhigher sensitivity and better repeatability for most analytes than the UHPSFC-MS/MS-based untargeted method. The established method was finally applied to investigatingthe lipid profiles of the plasma from the depressed rats and 33 differential variableswere screened, which related to three metabolic pathways. The results indicated thatthe UHPSFC-MS/MS-based pseudotargeted method is reliable and efficient and couldbe used in the lipidomics studies.
Collapse
|
48
|
Gradient supercritical fluid chromatography coupled to mass spectrometry with a gradient flow of make-up solvent for enantioseparation of cathinones. J Chromatogr A 2020; 1625:461286. [DOI: 10.1016/j.chroma.2020.461286] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Revised: 05/27/2020] [Accepted: 05/29/2020] [Indexed: 12/17/2022]
|
49
|
Havnen H, Hansen M, Spigset O, Hegstad S. Enantiomeric separation and quantification of R/S‐amphetamine in serum using semi‐automated liquid‐liquid extraction and ultra‐high performance supercritical fluid chromatography‐tandem mass spectrometry. Drug Test Anal 2020; 12:1344-1353. [DOI: 10.1002/dta.2879] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 05/20/2020] [Accepted: 06/10/2020] [Indexed: 01/14/2023]
Affiliation(s)
- Hilde Havnen
- Department of Clinical Pharmacology St. Olav University Hospital Trondheim Norway
| | - Miriam Hansen
- Department of Clinical Pharmacology St. Olav University Hospital Trondheim Norway
| | - Olav Spigset
- Department of Clinical Pharmacology St. Olav University Hospital Trondheim Norway
- Department of Clinical and Molecular Medicine Norwegian University of Science and Technology Trondheim Norway
| | - Solfrid Hegstad
- Department of Clinical Pharmacology St. Olav University Hospital Trondheim Norway
| |
Collapse
|
50
|
Abstract
Vitamin D and its analogues are fat-soluble vitamins that carry out important functions in human and animal organisms. Many studies have pointed out the relationship between the deficiency of these substances and the development of both skeletal- and extra-skeletal diseases. Although vitamin D is fundamentally derived from the bio-transformation of its precursor, 7-dehydrocholesterol, through the action of UV-B radiation in the skin, dietary intake also plays an important role in the regulation of its status in an organism. For this reason, the application of reliable methodologies that enable monitoring the content of vitamin D and its analogues in food and supplements constitutes an aspect of special relevance to establish adequate habits, which avoid the deficiency of these substances in organisms and, consequently, the appearance of related diseases. The use of chromatographic techniques in combination with conventional and novel sample pre-treatments has become a suitable strategy to achieve this aim. This review compiles the most relevant methodologies reported in the last ten years for vitamin D analogues analysis in food matrices. Particular attention has been paid to provide a general overview of the most suitable approaches in terms of reliability, sensitivity and simplicity, used in the field of food analysis.
Collapse
|