1
|
Aebischer MK, Chapel S, Guillarme D, Heinisch S. Theoretical and practical guidelines for solvent dilution between the two dimensions in online comprehensive two-dimensional liquid chromatography. J Chromatogr A 2024; 1718:464725. [PMID: 38364617 DOI: 10.1016/j.chroma.2024.464725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 01/23/2024] [Accepted: 02/07/2024] [Indexed: 02/18/2024]
Abstract
Online comprehensive two-dimensional liquid chromatography (online LC x LC) has become increasingly popular. Among the different chromatographic modes that can be combined, hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) are particularly interesting because they offer a high degree of orthogonality. However, this combination remains complex due to the incompatibility of the solvents in the two dimensions. To avoid this problem, it is possible to dilute the first dimension (1D) effluent with (zdilution -1) volumes of a weaker solvent added to one volume of 1D-effluent, where zdilution represents the extent to which the fraction volume has been multiplied. This can be done using either active solvent modulation technology or an additional pump, prior to the second dimension analysis. The objective of this study was to develop theoretical models to predict whether or not dilution can be effective, and, if so, what is the minimum zdilution value required. This approach is based on the calculation of the ratio (called xdilution) between the peak standard deviation due to the injection process and the peak standard deviation in the absence of extra-column dispersion. xdilution was calculated from theoretical relationships and plotted as a function of zdilution, to predict the value required to obtain good peak shapes for the compound of interest. The maximum xdilution value was found to be of the order of 1 for chromatographically acceptable peak shapes. The proposed theoretical approach was experimentally validated on a number of representative small molecules and peptides. Agreement between experimental results and theoretical models was very high, especially for small molecules. Finally, it is shown that this approach helps to predict the most appropriate set of conditions in HILIC x RPLC, depending on the compounds to be separated.
Collapse
Affiliation(s)
- Megane K Aebischer
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel Servet 1, 1211, Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211, Geneva 4, Switzerland
| | - Soraya Chapel
- Laboratoire SMS-EA3233, Université Rouen Normandie, FR3038 INC3M, Unirouen, Place Emile Blondel, F-76821, Mont-Saint-Aignan, France
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel Servet 1, 1211, Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211, Geneva 4, Switzerland.
| | - Sabine Heinisch
- Université de Lyon, Institut des Sciences Analytiques, UMR 5280 CNRS, 5 rue de la Doua, 69100, Villeurbanne, France
| |
Collapse
|
2
|
Barros de Souza A, Ali I, van de Goor T, Dewil R, Cabooter D. Comprehensive two-dimensional liquid chromatography with high resolution mass spectrometry to investigate the photoelectrochemical degradation of environmentally relevant pharmaceuticals and their degradation products in water. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2024; 351:120023. [PMID: 38181683 DOI: 10.1016/j.jenvman.2024.120023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 12/26/2023] [Accepted: 01/02/2024] [Indexed: 01/07/2024]
Abstract
The widespread presence of organic micropollutants in the environment reflects the inability of traditional wastewater treatment plants to remove them. In this context, advanced oxidation processes (AOPs) have emerged as promising quaternary wastewater treatment technologies since they efficiently degrade recalcitrant components by generating highly reactive free radicals. Nonetheless, the chemical characterization of potentially harmful byproducts is essential to avoid the contamination of natural water bodies with hazardous substances. Given the complexity of wastewater matrices, the implementation of comprehensive analytical methodologies is required. In this work, the simultaneous photoelectrochemical degradation of seven environmentally relevant pharmaceuticals and one metabolite from the EU Watch List 2020/1161 was examined in ultrapure water and simulated wastewater, achieving excellent removal efficiencies (overall >95%) after 180 min treatment. The reactor unit was linked to an online LC sample manager, allowing for automated sampling every 15 min and near real-time process monitoring. Online comprehensive two-dimensional liquid chromatography (LC × LC) coupled with high resolution mass spectrometry (HRMS) was subsequently used to tentatively identify degradation products after photoelectrochemical degradation. Two reversed-phase liquid chromatography (RPLC) columns were used: an SB-C18 column operated with 5 mM ammonium formate at pH 5.8 (1A) and methanol (1B) as the mobile phases in the first dimension and an SB-Aq column using acidified water at pH 3.1 (2A) and acetonitrile (2B) as the mobile phases in the second dimension. This resulted in a five-fold increase in peak capacity compared to one-dimensional LC while maintaining the same total analysis time of 50 min. The LC x LC method allowed the tentative identification of 12 venlafaxine, 7 trimethoprim and 10 ciprofloxacin intermediates. Subsequent toxicity predictions suggested that some of these byproducts were potentially harmful. This study presents an effective hybrid technology for the simultaneous removal of pharmaceuticals from contaminated wastewater matrices and demonstrates how multidimensional liquid chromatography techniques can be applied to better understand the degradation mechanisms after the treatment of micropollutants with AOPs.
Collapse
Affiliation(s)
- Allisson Barros de Souza
- Agilent Technologies Deutschland, Hewlett-Packard-Strasse 8, 76337, Waldbronn, Germany; KU Leuven, Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, Herestraat 49, 3000, Leuven, Belgium
| | - Izba Ali
- InOpSys - Mobiele Waterzuivering voor Chemie en Farma, Maanstraat 9b, 2800, Mechelen, Belgium; KU Leuven, Department of Chemical Engineering, Process and Environmental Technology Lab, J. De Nayerlaan 5, 2860, Sint-Katelijne-Waver, Belgium
| | - Tom van de Goor
- Agilent Technologies Deutschland, Hewlett-Packard-Strasse 8, 76337, Waldbronn, Germany
| | - Raf Dewil
- KU Leuven, Department of Chemical Engineering, Process and Environmental Technology Lab, J. De Nayerlaan 5, 2860, Sint-Katelijne-Waver, Belgium; University of Oxford, Department of Engineering Science, Parks Road, Oxford, OX1 3PJ, United Kingdom
| | - Deirdre Cabooter
- KU Leuven, Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, Herestraat 49, 3000, Leuven, Belgium.
| |
Collapse
|
3
|
Pardon M, Reis R, de Witte P, Chapel S, Cabooter D. Detailed comparison of in-house developed and commercially available heart-cutting and selective comprehensive two-dimensional liquid chromatography systems. J Chromatogr A 2024; 1713:464565. [PMID: 38096685 DOI: 10.1016/j.chroma.2023.464565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Revised: 11/21/2023] [Accepted: 12/05/2023] [Indexed: 01/08/2024]
Abstract
Recently, two-dimensional liquid chromatography (2D-LC) has become a popular approach to analyze complex samples. This is partly due to the introduction of commercial 2D-LC systems. In the past, 2D-LC was carried out on in-house developed setups, typically consisting of several switching valves and sample loops as the interface between the two dimensions. Commercial systems usually offer different 2D-LC modes in combination with specialized software to operate the instrument and analyze the data. This makes them highly user-friendly, however, at an increased cost compared to in-house developed setups. This study aims to make a comparison between an in-house developed 2D-LC setup and a commercially available 2D-LC instrument. The comparison is made based on experimental differences, in addition to more general differences, including cost price, flexibility, and ease of operation. Special attention is also paid to the different strategies to deal with the mobile phase incompatibility between the highly orthogonal separation mechanisms considered in this work: hydrophilic interaction liquid chromatography (HILIC) and reversed-phase LC (RPLC). For the commercial 2D-LC instrument, this is done using active solvent modulation (ASM), a valve-based approach allowing the on-line dilution of the effluent eluting from the first dimension column before transfer to the second dimension (2D) column. For the in-house developed setup, a combination of restriction capillaries and a trap column is used. Using a sample of 28 compounds with a large polarity range, peak shapes and recoveries of the 2D-chromatograms are compared for both setups. For early eluting compounds, the selective comprehensive approach, currently only possible on the commercial 2D-LC instrument, results in the best peak shapes and recoveries, however, at the cost of an increased analysis time. In general, depending on the analytical goal (single heart-cut versus full-comprehensive 2D-LC), an in-house developed system can be satisfactory for the analysis of specific target compounds/samples. For more complex problems, it can be interesting to use a more specialized commercial 2D-LC instrument. Overall, this comparison study provides advice for analytical scientists, who are considering to use 2D-LC, on the type of equipment to consider, depending on the needs of their particular applications.
Collapse
Affiliation(s)
- Marie Pardon
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium; Laboratory for Molecular Biodiscovery, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Rafael Reis
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Peter de Witte
- Laboratory for Molecular Biodiscovery, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Soraya Chapel
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Deirdre Cabooter
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium.
| |
Collapse
|
4
|
Xu XY, Jiang MT, Wang Y, Sun H, Jing Q, Li XH, Xu B, Zou YD, Yu HS, Li Z, Guo DA, Yang WZ. Multiple heart-cutting two-dimensional liquid chromatography/charged aerosol detector assay of ginsenosides for quality evaluation of ginseng from diverse Chinese patent medicines. J Chromatogr A 2023; 1708:464344. [PMID: 37703763 DOI: 10.1016/j.chroma.2023.464344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 08/24/2023] [Accepted: 08/29/2023] [Indexed: 09/15/2023]
Abstract
For quality control of Chinese patent medicines (CPMs) containing the same herbal medicine or different herbal medicines that have similar chemical composition, current ″one standard for one species″ research mode leads to poor universality of the analytical approaches unfavorable to discriminate easily confused species. Herein, we were aimed to elaborate a multiple heart-cutting two-dimensional liquid chromatography/charged aerosol detector (MHC-2DLC/CAD) approach to quantitatively assess ginseng from multiple CPMs. Targeting baseline resolution of 16 ginsenosides (noto-R1/Rg1/Re/Rf/Ra2/Rb1/Rc/Ro/Rb2/Rb3/Rd/Rh1/Rg2/Rg3/Rg3(R)/24(R)-p-F11), experiments were conducted to optimize key parameters and validate its performance. A Poroshell 120 EC-C18 column and an XBridge Shield RP18 column were separately utilized in the first-dimensional (1D) and the second-dimensional (2D) chromatography. Eight consecutive cuttings could achieve good separation of 16 ginsenosides within 85 min. The developed MHC-2DLC/CAD method showed good linearity (R2 > 0.999), repeatability (RSD < 6.73%), stability (RSD < 5.63%), inter- and intra-day precision (RSD < 5.57%), recovery (93.76-111.14%), and the limit of detection (LOD) and limit of quantification (LOQ) varied between 0.45-2.37 ng and 0.96-4.71 ng, respectively. We applied it to the content determination of 16 ginsenosides simultaneously from 28 different ginseng-containing CPMs, which unveiled the ginsenoside content difference among the tested CPMs, and gave useful information to discriminate ginseng in the preparation samples, as well. The MHC-2DLC/CAD approach exhibited advantages of high specificity, good separation ability, and relative high analysis efficiency, which also justified the feasibility of our proposed ″Monomethod Characterization of Structure Analogs″ strategy in quality evaluation of diverse CPMs that contained different ginseng.
Collapse
Affiliation(s)
- Xiao-Yan Xu
- National Key Laboratory of Chinese Medicine Modernization, State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China
| | - Mei-Ting Jiang
- National Key Laboratory of Chinese Medicine Modernization, State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China
| | - Yu Wang
- National Key Laboratory of Chinese Medicine Modernization, State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China
| | - He Sun
- National Key Laboratory of Chinese Medicine Modernization, State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China
| | - Qi Jing
- National Key Laboratory of Chinese Medicine Modernization, State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China
| | - Xiao-Hang Li
- National Key Laboratory of Chinese Medicine Modernization, State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China
| | - Bei Xu
- National Key Laboratory of Chinese Medicine Modernization, State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China
| | - Ya-Dan Zou
- National Key Laboratory of Chinese Medicine Modernization, State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China
| | - He-Shui Yu
- National Key Laboratory of Chinese Medicine Modernization, State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China; College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China
| | - Zheng Li
- National Key Laboratory of Chinese Medicine Modernization, State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China; College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, China
| | - De-An Guo
- National Key Laboratory of Chinese Medicine Modernization, State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China; National Engineering Laboratory for TCM Standardization Technology, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, 501 Haike Road, Shanghai 201203, China.
| | - Wen-Zhi Yang
- National Key Laboratory of Chinese Medicine Modernization, State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin 301617, China.
| |
Collapse
|
5
|
Chapel S, Rouvière F, Guillarme D, Heinisch S. Reversed HILIC Gradient: A Powerful Strategy for On-Line Comprehensive 2D-LC. Molecules 2023; 28:molecules28093907. [PMID: 37175317 PMCID: PMC10179806 DOI: 10.3390/molecules28093907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/25/2023] [Accepted: 04/27/2023] [Indexed: 05/15/2023] Open
Abstract
The aim of the present work is to evaluate the possibilities and limitations of reversed hydrophilic interaction chromatography (revHILIC) mode in liquid chromatography (LC). This chromatographic mode consists of combining a highly polar stationary phase (bare silica) with a gradient varying from very low (1-5%) to high (40%) acetonitrile content (reversed gradient compared to HILIC). The retention behavior of revHILIC was first compared with that of reversed-phase LC (RPLC) and HILIC using representative mixtures of peptides and pharmaceutical compounds. It appears that the achievable selectivity can be ranked in the order RPLC > revHILIC > HILIC with the two different samples. Next, two-dimensional liquid chromatography (2D-LC) conditions were evaluated by combining RPLC, revHILIC, or HILIC with RPLC in an on-line comprehensive (LC × LC) mode. evHILIC × RPLC not only showed impressive performance in terms of peak capacity and sensitivity, but also provided complementary selectivity compared to RPLC × RPLC and HILIC × RPLC. Indeed, both the elution order and the retention time range differ significantly between the three techniques. In conclusion, there is no doubt that revHILIC should be considered as a viable option for 2D-LC analysis of small molecules and also peptides.
Collapse
Affiliation(s)
- Soraya Chapel
- Institut Des Sciences Analytiques, Université de Lyon, UMR 5280, CNRS, 5 rue de la Doua, 69100 Villeurbanne, France
- Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, University of Leuven (KU Leuven), Herestraat 49, 3000 Leuven, Belgium
| | - Florent Rouvière
- Institut Des Sciences Analytiques, Université de Lyon, UMR 5280, CNRS, 5 rue de la Doua, 69100 Villeurbanne, France
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Sabine Heinisch
- Institut Des Sciences Analytiques, Université de Lyon, UMR 5280, CNRS, 5 rue de la Doua, 69100 Villeurbanne, France
| |
Collapse
|
6
|
Xu X, Jiang M, Li X, Wang Y, Liu M, Wang H, Mi Y, Chen B, Gao X, Yang W. Three-dimensional characteristic chromatogram by online comprehensive two-dimensional liquid chromatography: Application to the identification and differentiation of ginseng from herbal medicines to various Chinese patent medicines. J Chromatogr A 2023; 1700:464042. [PMID: 37163941 DOI: 10.1016/j.chroma.2023.464042] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 04/26/2023] [Accepted: 05/02/2023] [Indexed: 05/12/2023]
Abstract
One bottleneck problem in the quality control of traditional Chinese medicine (TCM) is the accurate identification of easily confused herbal medicines from Chinese patent medicine (CPM). Ginseng products derived from the multiple parts (e.g., root/rhizome, leaf, and flower bud) of multiple Panax species (P. ginseng, P. quinquefolius, P. notoginseng, P. japonicus, and P. japonicus var. major) are globally popular; however, their authentication is very challenging. Using online comprehensive two-dimensional liquid chromatography (LC × LC), we propose the concept of a three-dimensional characteristic chromatogram (3D CC) by integrating enhanced LC × LC separation and a contour plot that visualizes the stereoscopic chromatographic peaks and examine its performance in authenticating various ginseng products. Targeted at the resolution of 17 ginsenoside markers, an online LC × LC/UV system with a 56 min analysis time was constructed: a CORTECS UPLC Shield RP 18 column running at 0.1 mL/min for the first-dimensional chromatography and a Poroshell SB-Aq column at 2.0 mL/min in shift gradient mode in the second dimension of separation. In particular, ginsenosides Rg1/Re and Rc/Ra1 were well resolved. According to the presence/absence of stereo peaks consistent with the main ginsenoside markers in the 3D CC and the depth of shade (depending on peak volume), it was feasible to use a single method to identify and distinguish among 12 different ginseng species as the drug materials and the use of ginseng simultaneously from 21 CPMs. Conclusively, a practical solution enabling the accurate identification of easily confused TCMs was provided, covering both the drug materials and the compound preparations.
Collapse
Affiliation(s)
- Xiaoyan Xu
- State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China
| | - Meiting Jiang
- State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China
| | - Xiaohang Li
- State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China
| | - Yu Wang
- State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China
| | - Meiyu Liu
- State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China
| | - Hongda Wang
- State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China
| | - Yueguang Mi
- State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China
| | - Boxue Chen
- State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China
| | - Xiumei Gao
- State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China; Key Laboratory of Pharmacology of Traditional Chinese Medical Formulae, Ministry of Education, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China
| | - Wenzhi Yang
- State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China; Haihe Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China; Key Laboratory of Pharmacology of Traditional Chinese Medical Formulae, Ministry of Education, Tianjin University of Traditional Chinese Medicine, 10 Poyanghu Road, Tianjin, 301617, China.
| |
Collapse
|
7
|
Optimizing transfer and dilution processes when using active solvent modulation in on-line two-dimensional liquid chromatography. Anal Chim Acta 2023; 1252:341040. [PMID: 36935135 DOI: 10.1016/j.aca.2023.341040] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 03/01/2023] [Accepted: 03/02/2023] [Indexed: 03/06/2023]
Abstract
Two-dimensional liquid chromatography (2D-LC) is becoming increasingly popular for the analysis of complex samples, which is partly due to the recent introduction of commercial 2D-LC systems. To deal with the mobile phase incompatibility between highly orthogonal retention mechanisms, such as hydrophilic interaction liquid chromatography (HILIC) and reversed-phase LC (RPLC), several strategies have been introduced over the years. One of these strategies is active solvent modulation (ASM), a valve-based approach allowing the on-line dilution of the effluent eluting from the first dimension before transfer to the second dimension. This strategy has gained a lot of attention and holds great potential, however, no clear guidelines are currently in place for its use. Therefore, this study aims to investigate how the ASM process can be optimized when using highly incompatible LC combinations, such as HILIC and RPLC, in a simplified selective comprehensive 2D-LC set-up (sHILIC x RPLC) to suggest guidelines for future users. Using a representative sample, the dilution factor (DF), the duration of the ASM phase, the filling percentage of the sample loops, and their unloading configuration are investigated and optimized. It is observed that a DF of 10 with an optimal ASM phase duration, a sample loop filling of maximum 25%, and an unloading configuration in backflush mode, result in the best peak shapes, intensities, and recoveries for early eluting compounds, while keeping the total analysis time minimal. Based on these results, some general recommendations are made that could also be applied in other 2D-LC modes, such as comprehensive 2D-LC (LC x LC), heart-cutting 2D-LC (LC-LC), and other chromatographic combinations with mobile phase incompatibility issues.
Collapse
|
8
|
Caño-Carrillo I, Gilbert-López B, Montero L, Martínez-Piernas AB, García-Reyes JF, Molina-Díaz A. Comprehensive and heart-cutting multidimensional liquid chromatography-mass spectrometry and its applications in food analysis. MASS SPECTROMETRY REVIEWS 2023. [PMID: 37056215 DOI: 10.1002/mas.21845] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 03/07/2023] [Accepted: 03/13/2023] [Indexed: 06/19/2023]
Abstract
In food analysis, conventional one-dimensional liquid chromatography methods sometimes lack sufficient separation power due to the complexity and heterogeneity of the analyzed matrices. Therefore, the use of two-dimensional liquid chromatography (2D-LC) turns out to be a powerful tool to consider, especially when coupled to mass spectrometry (MS). This review presents the most remarkable 2D-LC-MS food applications reported in the last 10 years, including a critical discussion of the multiple approaches, modulation strategies as well as the importance of the optimization of the different analytical aspects that will condition the 2D-LC-MS performance. The presence of contaminants in food (food safety), the food quality, and authenticity or the relationship between the beneficial effects of food and human health are some of the fields in which most of the 2D-LC-MS applications are mainly focused. Both heart-cutting and comprehensive applications are described and discussed in this review, highlighting the potential of 2D-LC-MS for the analysis of such complex samples.
Collapse
Affiliation(s)
- Irene Caño-Carrillo
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
| | - Bienvenida Gilbert-López
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
- University Research Institute for Olives Grove and Olive Oil, University of Jaén, Jaén, Spain
| | - Lidia Montero
- Institute of Food Science Research-CIAL (CSIC-UAM), Madrid, Spain
| | - Ana B Martínez-Piernas
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
| | - Juan F García-Reyes
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
- University Research Institute for Olives Grove and Olive Oil, University of Jaén, Jaén, Spain
| | - Antonio Molina-Díaz
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
- University Research Institute for Olives Grove and Olive Oil, University of Jaén, Jaén, Spain
| |
Collapse
|
9
|
Caño-Carrillo I, Gilbert-López B, Montero L, Martínez-Piernas AB, García-Reyes JF, Molina-Díaz A. Comprehensive and heart-cutting multidimensional liquid chromatography-mass spectrometry and its applications in food analysis. MASS SPECTROMETRY REVIEWS 2023. [PMID: 37010157 DOI: 10.1002/mas.21843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 03/07/2023] [Accepted: 03/13/2023] [Indexed: 06/19/2023]
Abstract
In food analysis, conventional one-dimensional liquid chromatography methods sometimes lack sufficient separation power due to the complexity and heterogeneity of the analysed matrices. Therefore, the use of two-dimensional liquid chromatography (2D-LC) turns out to be a powerful tool to consider, especially when coupled to mass spectrometry (MS). This review presents the most remarkable 2D-LC-MS food applications reported in the last 10 years, including a critical discussion of the multiple approaches, modulation strategies as well as the importance of the optimisation of the different analytical aspects that will condition the 2D-LC-MS performance. The presence of contaminants in food (food safety), the food quality and authenticity or the relationship between the beneficial effects of food and human health are some of the fields in which most of the 2D-LC-MS applications are mainly focused. Both heart-cutting and comprehensive applications are described and discussed in this review, highlighting the potential of 2D-LC-MS for the analysis of such complex samples.
Collapse
Affiliation(s)
- Irene Caño-Carrillo
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
| | - Bienvenida Gilbert-López
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
- University Research Institute for Olives Grove and Olive Oil, University of Jaén, Jaén, Spain
| | - Lidia Montero
- Institute of Food Science Research-CIAL (CSIC-UAM), Madrid, Spain
| | - Ana B Martínez-Piernas
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
| | - Juan F García-Reyes
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
- University Research Institute for Olives Grove and Olive Oil, University of Jaén, Jaén, Spain
| | - Antonio Molina-Díaz
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
- University Research Institute for Olives Grove and Olive Oil, University of Jaén, Jaén, Spain
| |
Collapse
|
10
|
Muller M, de Villiers A. A detailed evaluation of the advantages and limitations of online RP-LC×HILIC compared to HILIC×RP-LC for phenolic analysis. J Chromatogr A 2023; 1692:463843. [PMID: 36780845 DOI: 10.1016/j.chroma.2023.463843] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 01/20/2023] [Accepted: 01/30/2023] [Indexed: 02/05/2023]
Abstract
The combination of hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RP-LC) has proved effective in the LC × LC analysis of polyphenols due to the high degree of orthogonality associated with these separation modes for various classes of phenolic compounds. However, despite the growing number of such applications, HILIC is almost exclusively used as the first dimension (1D) separation mode, and RP-LC in the second dimension (2D). This is somewhat surprising in light of the potential advantages of swapping these separation modes. In this contribution, we present a detailed evaluation of the potential of online RP-LC × HILIC-MS for the analysis of phenolic compounds, comparing the performance of this system to the more established HILIC × RP-LC-MS configuration. Method development was performed using a predictive optimisation program, and fixed solvent modulation was employed to combat the solvent incompatibility between HILIC and RP-LC mobile phases. Red wine, rooibos tea, Protea and chestnut phenolic extracts containing a large diversity of phenolic compound classes were analysed by both HILIC × RP-LC- and RP-LC × HILIC-MS in order to compare the separation performance. Overall, the kinetic performance of HILIC × RP-LC was found to be clearly superior, with higher peak capacities and better resolution obtained for the majority of samples compared to RP-LC × HILIC analyses using similar column dimensions. Dilution of the 1D solvent combined with large volume injections proved insufficient to focus especially phenolic acids in the 2D HILIC separation, which resulted in severe 2D peak distortion for these compounds, and negatively impacted on method performance. On the other hand, a noteworthy improvement in the sensitivity of RP-LC × HILIC-MS analyses was observed due to higher ESI-MS response for the 2D HILIC mobile phase and greater sample loading capacity of the 1D RP-LC column, brought on by the high solubility of phenolic samples in aqueous solutions. As a result, a significantly higher number of compounds were detected in the RP-LC × HILIC-MS separations. These findings point to the potential advantage of RP-LC × HILIC as a complementary configuration to HILIC × RP-LC for phenolic analysis.
Collapse
Affiliation(s)
- Magriet Muller
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, Matieland, 7602, South Africa
| | - André de Villiers
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, Matieland, 7602, South Africa.
| |
Collapse
|
11
|
Zhang L, Shen L, Zhong Q, Zhou T. Diluting modulation-based two dimensional-liquid chromatography coupled with mass spectrometry for simultaneously determining multiclass prohibited substances in cosmetics. J Chromatogr A 2023; 1695:463954. [PMID: 37011524 DOI: 10.1016/j.chroma.2023.463954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 03/16/2023] [Accepted: 03/26/2023] [Indexed: 03/29/2023]
Abstract
Developing efficient and comprehensive screening methods for prohibited substances in cosmetics is critical for ensuring the quality and safety of cosmetics used in everyday life. This study proposed a heart-cutting two-dimensional liquid chromatography-mass spectrometry (2D-LC-MS) method based on online diluting modulation for detecting multiclass prohibited substances in cosmetics. The 2D-LC-MS method combines HILIC and RPLC techniques. Compounds near the dead time that the first dimensional HILIC could not separate were transferred to the second dimensional RPLC by valve switch, achieving good separation with a wide range of polarities. Moreover, the online diluting modulation solved the problem of mobile phase incompatibility, realizing an excellent column-head focusing effect and reducing the loss of sensitivity. Besides, the first dimensional analysis did not restrict the flow rate of the second dimensional analysis owing to the diluting modulation. We demonstrated the 2D-LC-MS system by determining 126 prohibited substances in cosmetic products, including hormones, local anesthetics, anti-infectives, adrenergic agents, antihistamines, pesticides, and other chemicals. All correlation coefficients of the compounds were above 0.9950. The LODs and the LOQs ranged from 0.000259 ng/mL to 16.6 ng/mL and 0.000864 ng/mL to 55.3 ng/mL, respectively. The RSDs% for intra-day and inter-day precision were within 6% and 14%, respectively. Compared with conventional one-dimensional liquid chromatography methods, the established method expanded the analytical coverage of cosmetics-prohibited substances with reduced matrix effects for most compounds and improved sensitivity for polar analytes. The results indicated that the 2D-LC-MS method was a powerful tool for screening multiclass prohibited substances in cosmetics.
Collapse
Affiliation(s)
- Liping Zhang
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou, 510006, China
| | - Lingling Shen
- Guangzhou Analytical Center, Analytical & Measuring Instruments Division, Shimadzu (China) Co., LTD, Guangzhou, 510010, China
| | - Qisheng Zhong
- Guangzhou Analytical Center, Analytical & Measuring Instruments Division, Shimadzu (China) Co., LTD, Guangzhou, 510010, China
| | - Ting Zhou
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou, 510006, China.
| |
Collapse
|
12
|
Segmented two-dimensional liquid chromatography. Proof of concept study. J Chromatogr A 2023; 1691:463811. [PMID: 36731333 DOI: 10.1016/j.chroma.2023.463811] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 01/17/2023] [Accepted: 01/18/2023] [Indexed: 01/26/2023]
Abstract
The separation in liquid chromatography is defined either by the space domain where it proceeds until the least retained analyte reaches the outlet of the column or by the time when individual analytes elute out of the column. These two approaches lead to the four possible combinations of two-dimensional liquid chromatography with online space x time coupling being the least experimentally feasible. Here, we show the development of a novel two-dimensional liquid chromatography method combining separation defined by space and the conventional elution-based separation. First-dimension column consisted of four capillary segments coupled serially via two-position six-port valves allowing an online and comprehensive transfer of analytes from the first to the second dimension. After initial experiments using homemade monolithic capillary columns, we tested commercially available columns in both dimensions. We ended with the combination of packed capillary columns in the first dimension and monolithic capillary column in the second dimension. We used a reversed-phase retention mechanism in the first spatial dimension, while HILIC was in the second, time-based dimension. We also developed a theoretical model to describe the proposed two-dimensional separation that was further confirmed by utilizing both an isocratic and gradient elution in the second dimension. Finally, we applied our experimental setup to separate neurotransmitters contained in human urine.
Collapse
|
13
|
Montero L, Ayala-Cabrera JF, Bristy FF, Schmitz OJ. Multi- 2D LC × LC as a Novel and Powerful Implement for the Maximum Separation of Complex Samples. Anal Chem 2023; 95:3398-3405. [PMID: 36721361 DOI: 10.1021/acs.analchem.2c04870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Achieving complete information about the chemical composition of complex samples requires the use of multianalytical platforms able to maximize the acquisition of high-quality data for unequivocal identification. However, this process requires long analysis times and several instruments. Food analysis is one of the analytical fields where the analysis of very complex samples has a huge impact. One of these complex samples is vermouth, a fortified wine based on the maceration of a large number of herbs, fruits, barks, seeds, and leaves. The application of conventional or even advanced analytical techniques like comprehensive two-dimensional (2D) liquid chromatography (LC × LC) does not provide enough separation power to resolve the complete profile of this sample. In this work, a novel 2DLC strategy called multi-2D LC × LC is developed. This new setup consists of the use of two different columns with different separation properties in the second dimension (2D) that can be selected during the LC × LC analysis accordingly to the chemical nature of the compounds eluted from the first dimension (1D). The vermouth sample was analyzed using a 1D-PFP and a combination of HILIC (from 0 to 30 min) and C18 (from 30 to the end) columns in the 2D. This setup increased both the peak capacity and the orthogonality of the analysis in comparison to the use of only one of the columns in the 2D. Multi-2D LC × LC is presented as an integrated 2DLC tool that maximizes the separation capacity for very complex samples.
Collapse
Affiliation(s)
- Lidia Montero
- Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstr. 5, 45141Essen, Germany.,Teaching and Research Center for Separation, University of Duisburg-Essen, Universitaetsstr. 5, 45141Essen, Germany
| | - Juan F Ayala-Cabrera
- Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstr. 5, 45141Essen, Germany.,Teaching and Research Center for Separation, University of Duisburg-Essen, Universitaetsstr. 5, 45141Essen, Germany
| | - Fariha F Bristy
- Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstr. 5, 45141Essen, Germany.,Teaching and Research Center for Separation, University of Duisburg-Essen, Universitaetsstr. 5, 45141Essen, Germany
| | - Oliver J Schmitz
- Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstr. 5, 45141Essen, Germany.,Teaching and Research Center for Separation, University of Duisburg-Essen, Universitaetsstr. 5, 45141Essen, Germany
| |
Collapse
|
14
|
Wicht K, Baert M, von Doehren N, Desmet G, de Villiers A, Lynen F. Speeding up temperature-responsive × reversed-phase comprehensive liquid chromatography through the combined exploitation of temperature and flow rate gradients. J Chromatogr A 2022; 1685:463584. [DOI: 10.1016/j.chroma.2022.463584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 10/15/2022] [Accepted: 10/18/2022] [Indexed: 11/27/2022]
|
15
|
Renai L, Del Bubba M, Samanipour S, Stafford R, Gargano AF. Development of a comprehensive two-dimensional liquid chromatographic mass spectrometric method for the non-targeted identification of poly- and perfluoroalkyl substances in aqueous film-forming foams. Anal Chim Acta 2022; 1232:340485. [DOI: 10.1016/j.aca.2022.340485] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 10/02/2022] [Accepted: 10/03/2022] [Indexed: 11/26/2022]
|
16
|
Pérez-Cova M, Platikanov S, Tauler R, Jaumot J. Quantification strategies for two-dimensional liquid chromatography datasets using regions of interest and multivariate curve resolution approaches. Talanta 2022; 247:123586. [PMID: 35671578 DOI: 10.1016/j.talanta.2022.123586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 05/23/2022] [Accepted: 05/24/2022] [Indexed: 11/16/2022]
Abstract
In this work, three chemometrics-based approaches are compared for quantification purposes when using two-dimensional liquid chromatography (LC×LC-MS), taking as a study case the quantification of amino acids in commercial drug mixtures. Although the approaches have been already used for one-dimensional gas or liquid chromatography, the main novelty of this work is the demonstration of their applicability to LC×LC-MS datasets. Besides, steps such as peak alignment and modelling, commonly applied in this type of data analysis, are not required with the approaches proposed here. In a first step, regions of interest (ROI) strategy is used for the spectral compression of the LC×LC-MS datasets. Then the first strategy consists of building a calibration curve from the areas obtained in this ROI compression step. Alternatively, the ROI intensity matrices can be used as input for a second analysis step employing the multivariate curve resolution alternating least squares (MCR-ALS) method. The main benefit of MCR-ALS is the resolution of elution and spectral profiles for each of the analytes in the mixture, even in the case of strong coelutions and high signal overlapping. Classical MCR-ALS based calibration curve from the peak areas resolved only applying non-negativity constraints (second strategy) is compared to the results obtained when an area correlation constraint is imposed during the ALS optimization (third strategy). All in all, similar quantification results were achieved by the three approaches but, especially in prediction studies, the more accurate quantification is obtained when the calibration curve is built from the peak areas obtained with MCR-ALS when the area correlation constraint is imposed.
Collapse
Affiliation(s)
- Miriam Pérez-Cova
- Department of Environmental Chemistry, IDAEA-CSIC, Jordi Girona 18-26, E08034 Barcelona, Spain; Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Diagonal 647, E08028, Barcelona, Spain.
| | - Stefan Platikanov
- Department of Environmental Chemistry, IDAEA-CSIC, Jordi Girona 18-26, E08034 Barcelona, Spain
| | - Romà Tauler
- Department of Environmental Chemistry, IDAEA-CSIC, Jordi Girona 18-26, E08034 Barcelona, Spain
| | - Joaquim Jaumot
- Department of Environmental Chemistry, IDAEA-CSIC, Jordi Girona 18-26, E08034 Barcelona, Spain
| |
Collapse
|
17
|
Foster SW, Parker D, Kurre S, Boughton J, Stoll DR, Grinias JP. A review of two-dimensional liquid chromatography approaches using parallel column arrays in the second dimension. Anal Chim Acta 2022; 1228:340300. [DOI: 10.1016/j.aca.2022.340300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 08/18/2022] [Accepted: 08/20/2022] [Indexed: 11/26/2022]
|
18
|
Liang L, Duan W, Zhao C, Zhang Y, Sun B. Recent Development of Two-Dimensional Liquid Chromatography in Food Analysis. FOOD ANAL METHOD 2022. [DOI: 10.1007/s12161-021-02190-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
19
|
Wicht K, Baert M, Muller M, Bandini E, Schipperges S, von Doehren N, Desmet G, de Villiers A, Lynen F. Comprehensive two-dimensional temperature-responsive × reversed phase liquid chromatography for the analysis of wine phenolics. Talanta 2022; 236:122889. [PMID: 34635268 DOI: 10.1016/j.talanta.2021.122889] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 09/13/2021] [Accepted: 09/14/2021] [Indexed: 11/18/2022]
Abstract
Phenolic compounds are an interesting class of natural products because of their proposed contribution to health benefits of foods and beverages and as a bio-source of organic (aromatic) building blocks. Phenolic extracts from natural products are often highly complex and contain compounds covering a broad range in molecular properties. While many 1D-LC and mass spectrometric approaches have been proposed for the analysis of phenolics, this complexity inevitably leads to challenging identification and purification. New insights into the composition of phenolic extracts can be obtained through online comprehensive two-dimensional liquid chromatography (LC × LC) coupled to photodiode array and mass spectrometric detection. However, several practical hurdles must be overcome to achieve high peak capacities and to obtain robust methods with this technique. In many LC × LC configurations, refocusing of analytes at the head of the 2D column is hindered by the high eluotropic strength of the solvent transferred from the 1D to the 2D, leading to peak breakthrough or broadening. LC × LC combinations whereby a purely aqueous mobile phase is used in the 1D and RPLC is used in the 2D are unaffected by these phenomena, leading to more robust methods. In this contribution, the combination of temperature-responsive liquid chromatography (TRLC) with RPLC is used for the first time for the analysis of phenolic extracts of natural origin to illustrate the potential of this alternative combination for natural product analyses. The possibilities of the combination are investigated through analysis of wine extracts by TRLC × RPLC-DAD and TRLC × RPLC-ESI-MS.
Collapse
Affiliation(s)
- Kristina Wicht
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium
| | - Mathijs Baert
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium
| | - Magriet Muller
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, ZA-7602, Matieland, South Africa
| | - Elena Bandini
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium
| | - Sonja Schipperges
- Agilent Technologies, Hewlett Packard St 8, D-76337, Waldbronn, Germany
| | - Norwin von Doehren
- Agilent Technologies, Netherlands BV, NL-4330, EA, Middelburg, Netherlands
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, B-1050, Brussel, Belgium
| | - André de Villiers
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, ZA-7602, Matieland, South Africa
| | - Frederic Lynen
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium.
| |
Collapse
|
20
|
Feng J, Zhong Q, Kuang J, Liu J, Huang T, Zhou T. Simultaneous Analysis of the Metabolome and Lipidome Using Polarity Partition Two-Dimensional Liquid Chromatography-Mass Spectrometry. Anal Chem 2021; 93:15192-15199. [PMID: 34739231 DOI: 10.1021/acs.analchem.1c03905] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Comprehensive metabolic profiling is a considerable challenge for systems biology since the metabolites in biological samples have significant polarity differences. A heart-cutting two-dimensional liquid chromatography-mass spectrometry (2D-LC-MS) method-based polarity partition was established to analyze both the metabolome and lipidome in a single run. Based on the polarity partition strategy, metabolites with high polarity were retained and separated by one-dimensional hydrophilic chromatography, while low- and medium-polarity lipids were collected into a sample loop and injected into two-dimensional reversed-phase chromatography for separation. A simple online dilution strategy realized the online coupling of the 2D-LC-MS, which effectively solved band broadening and peak distortion caused by solvent incompatibility. Moreover, a dual gradient elution procedure was introduced to further broaden the coverage of low-polarity lipids. The metabolites' log P values, which this 2D-LC-MS method could analyze, ranged from -8.79 to 26.86. The feasibility of the 2D-LC-MS system was demonstrated by simultaneous analysis of the metabolome and lipidome in rat plasma related to depression. A total of 319 metabolites were determined within 40 min, including organic acids, nucleosides, carbohydrate derivatives, amino acids, lipids, and other organic compounds. Finally, 44 depression-related differential metabolites were screened. Compared with conventional LC-MS-based methods, the 2D-LC method covered over 99% of features obtained by two conventional methods. In addition, the selectivity and resolution of the hydrophilic metabolites were improved, and the matrix effects of the hydrophobic metabolites were reduced in the developed method. The results indicated that the established 2D-LC system is a powerful tool for comprehensive metabolomics studies.
Collapse
Affiliation(s)
- Jieqing Feng
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou 510006, China
| | - Qisheng Zhong
- Guangzhou Analytical Applications Center, Shimadzu (China) Co., LTD, Guangzhou 510010, China
| | - Jiangmeng Kuang
- Guangzhou Analytical Applications Center, Shimadzu (China) Co., LTD, Guangzhou 510010, China
| | - Jiaqi Liu
- Guangzhou Analytical Applications Center, Shimadzu (China) Co., LTD, Guangzhou 510010, China
| | - Taohong Huang
- Shanghai Analytical Applications Center, Shimadzu (China) Co., LTD, Shanghai 200233, China
| | - Ting Zhou
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou 510006, China
| |
Collapse
|
21
|
Chapel S, Heinisch S. Strategies to circumvent the solvent strength mismatch problem in online comprehensive two-dimensional liquid chromatography. J Sep Sci 2021; 45:7-26. [PMID: 34525266 DOI: 10.1002/jssc.202100534] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 08/23/2021] [Accepted: 08/24/2021] [Indexed: 11/09/2022]
Abstract
On-line comprehensive two-dimensional liquid chromatography is a powerful technique for the separation of highly complex samples. Due to the addition of the second dimension of separation, impressive peak capacities can be obtained within a reasonable analysis time compared to one-dimensional liquid chromatography. In online comprehensive two-dimensional liquid chromatography, the separation power is maximized by selecting two separation dimensions as orthogonal as possible, which most often requires the combination of different mobile phases and stationary phases. The online transfer of a given solvent from the first dimension to the second dimension may cause severe injection effects in the second dimension, mostly due to solvent strength mismatch. Those injection effects may include peak broadening, peak distortion, peak splitting or breakthrough phenomenon. They are often found to reduce significantly the peak capacity and the peak intensity. To overcome such effects, arising specifically in online comprehensive two-dimensional liquid chromatography, different methods have been developed over the years. In this review, we focused on the most recently reported ones. A critical discussion, supported by a theoretical approach, gives an overview of their advantages and drawbacks.
Collapse
Affiliation(s)
- Soraya Chapel
- Université de Lyon, Institut des sciences analytiques, Villeurbanne, France
| | - Sabine Heinisch
- Université de Lyon, Institut des sciences analytiques, Villeurbanne, France
| |
Collapse
|
22
|
A comprehensive study on the phenomenon of total breakthrough in liquid chromatography. J Chromatogr A 2021; 1653:462399. [PMID: 34284262 DOI: 10.1016/j.chroma.2021.462399] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Revised: 07/03/2021] [Accepted: 07/05/2021] [Indexed: 01/07/2023]
Abstract
Differences in elution strength between the sample solvent and the mobile phase usually give rise to undesirable effects on the chromatographic separation, which may range from slight broadening to severe peak deformation or even splitting. In the most extreme case, the retention factor of the analyte at the head of the column is so small at the time of injection that part of the analyte goes through the column with very little interaction with the stationary phase and hence elutes very close to the column dead time. This phenomenon is known as breakthrough. Usually, during breakthrough, the retained peak displays a wide array of deformations and it is not rare that multiple retained peaks appear for a given injected analyte. However, under certain conditions, it has been demonstrated that these deleterious effects could fully disappear, leaving only one breakthrough peak and one symmetrical peak on the chromatogram. This so-called "total breakthrough" phenomenon was recently highlighted in the specific context of the 2D-LC separation of peptides but has yet to be explained. In the present paper, we describe the results of a comprehensive study aiming to better understand and define the conditions of emergence of both breakthrough and total breakthrough phenomena in liquid chromatography. The effects of a broad range of parameters, including the nature of the solute, the retention mechanism, the injection and elution conditions, the column temperature, and the injected sample concentration on the occurrence of both phenomena were investigated. While breakthrough was found to occur for all studied compounds, it appears that the presence of positive charges on the molecule is a prerequisite for observing a total breakthrough phenomenon. Among all the parameters investigated in this work, only the injection conditions and the analyte retention were found to be impactful on the onset of both phenomena. This finding allowed us to suggest one necessary and sufficient condition, relying on the injection of critical volumes to observe each respective phenomenon. These critical volumes only depend on the column dead volume and the retention factor of the analyte in the injection solvent.
Collapse
|
23
|
Rausch AK, Brockmeyer R, Schwerdtle T. Development, validation, and application of a multi-method for the determination of mycotoxins, plant growth regulators, tropane alkaloids, and pesticides in cereals by two-dimensional liquid chromatography tandem mass spectrometry. Anal Bioanal Chem 2021; 413:3041-3054. [PMID: 33713146 PMCID: PMC8044062 DOI: 10.1007/s00216-021-03239-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 01/21/2021] [Accepted: 02/16/2021] [Indexed: 12/11/2022]
Abstract
Mycotoxins and pesticides regularly co-occur in agricultural products worldwide. Thus, humans can be exposed to both toxic contaminants and pesticides simultaneously, and multi-methods assessing the occurrence of various food contaminants and residues in a single method are necessary. A two-dimensional high performance liquid chromatography tandem mass spectrometry method for the analysis of 40 (modified) mycotoxins, two plant growth regulators, two tropane alkaloids, and 334 pesticides in cereals was developed. After an acetonitrile/water/formic acid (79:20:1, v/v/v) multi-analyte extraction procedure, extracts were injected into the two-dimensional setup, and an online clean-up was performed. The method was validated according to Commission Decision (EC) no. 657/2002 and document N° SANTE/12682/2019. Good linearity (R2 > 0.96), recovery data between 70-120%, repeatability and reproducibility values < 20%, and expanded measurement uncertainties < 50% were obtained for a wide range of analytes, including very polar substances like deoxynivalenol-3-glucoside and methamidophos. However, results for fumonisins, zearalenone-14,16-disulfate, acid-labile pesticides, and carbamates were unsatisfying. Limits of quantification meeting maximum (residue) limits were achieved for most analytes. Matrix effects varied highly (-85 to +1574%) and were mainly observed for analytes eluting in the first dimension and early-eluting analytes in the second dimension. The application of the method demonstrated the co-occurrence of different types of cereals with 28 toxins and pesticides. Overall, 86% of the samples showed positive findings with at least one mycotoxin, plant growth regulator, or pesticide.
Collapse
Affiliation(s)
- Ann-Kristin Rausch
- Department of Food Chemistry, Institute of Nutritional Science, University of Potsdam, Arthur-Scheunert-Allee 114-116, 14558, Nuthetal, Germany.
- Eurofins SOFIA GmbH, Rudower Chaussee 29, 12489, Berlin, Germany.
| | | | - Tanja Schwerdtle
- Department of Food Chemistry, Institute of Nutritional Science, University of Potsdam, Arthur-Scheunert-Allee 114-116, 14558, Nuthetal, Germany
- German Federal Institute for Risk Assessment, Max-Dohrn-Straße 8-10, 10589, Berlin, Germany
| |
Collapse
|
24
|
Cacciola F, Arena K, Mandolfino F, Donnarumma D, Dugo P, Mondello L. Reversed phase versus hydrophilic interaction liquid chromatography as first dimension of comprehensive two-dimensional liquid chromatography systems for the elucidation of the polyphenolic content of food and natural products. J Chromatogr A 2021; 1645:462129. [PMID: 33864987 DOI: 10.1016/j.chroma.2021.462129] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 03/22/2021] [Accepted: 03/25/2021] [Indexed: 12/19/2022]
Abstract
Comprehensive two-dimensional liquid chromatography is a well-established method for the unraveling of very complex real-world samples. With regard to food and natural products such a technique turned out to be a very promising approach due to its high resolving power and improved identification capability, especially in combination with mass spectrometry. In this context, polyphenols comprise a particular complex class of bioactive compounds, due to their nature and content in commonly consumed foodstuffs, making their analysis challenging. The present contribution shows an overview of the two commonly employed approaches used for polyphenol analysis, viz. RP-LC × RP-LC and HILIC × RP-LC. Furthermore, the latest implementations as well as limitations and future perspectives are critically reported.
Collapse
Affiliation(s)
- Francesco Cacciola
- Department of Biomedical, Dental, Morphological and Functional Imaging Sciences, University of Messina, 98125 Messina, Italy.
| | - Katia Arena
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy
| | - Filippo Mandolfino
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy
| | - Danilo Donnarumma
- Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy
| | - Paola Dugo
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy; Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy
| | - Luigi Mondello
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy; Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy; Department of Sciences and Technologies for Human and Environment, University Campus Bio-Medico of Rome, 00128 Rome, Italy; BeSep s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, 98168 Messina, Italy
| |
Collapse
|
25
|
Kaplitz AS, Mostafa ME, Calvez SA, Edwards JL, Grinias JP. Two‐dimensional separation techniques using supercritical fluid chromatography. J Sep Sci 2020; 44:426-437. [DOI: 10.1002/jssc.202000823] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Revised: 09/17/2020] [Accepted: 10/06/2020] [Indexed: 02/05/2023]
Affiliation(s)
| | | | - Samantha A. Calvez
- Department of Chemistry & Biochemistry Rowan University Glassboro NJ USA
| | | | - James P. Grinias
- Department of Chemistry & Biochemistry Rowan University Glassboro NJ USA
| |
Collapse
|
26
|
Farsang E, Guillarme D, Veuthey JL, Beck A, Lauber M, Schmudlach A, Fekete S. Coupling non-denaturing chromatography to mass spectrometry for the characterization of monoclonal antibodies and related products. J Pharm Biomed Anal 2020; 185:113207. [DOI: 10.1016/j.jpba.2020.113207] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Revised: 02/21/2020] [Accepted: 02/22/2020] [Indexed: 01/31/2023]
|
27
|
Strategies for effective development of ultra-sensitive LC–MS/MS assays: application to a novel STING agonist. Bioanalysis 2020; 12:467-484. [DOI: 10.4155/bio-2020-0038] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Background: The continual need for the development and validation of ultra-sensitive (low pg/ml) LC–MS/MS assays in the pharmaceutical industry is largely driven by the ultra-low analyte exposure or very low sample volume. Methodology: Strategies and systematic approaches for sensitivity enhancement are provided which cover all aspects of a LC–MS/MS bioanalysis. A case study where such strategies were applied for the validation of a 5.0 pg/ml assay for a STING agonist is discussed. Conclusion: Analytical protocols were developed to extract analytes from large volume of plasma samples (600 and 400 μl) with high throughput. The guidance provided in this publication can serve as a resource to influence LC–MS/MS method development activities.
Collapse
|
28
|
Nardiello D, Melfi MT, Pignatelli C, Centonze D. Enhancing online protein isolation as intact species from soy flour samples by actively modulated two-dimensional liquid chromatography (2D-LC). J Pharm Biomed Anal 2020; 179:112976. [PMID: 31757574 DOI: 10.1016/j.jpba.2019.112976] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Revised: 11/03/2019] [Accepted: 11/05/2019] [Indexed: 10/25/2022]
Abstract
In this study, an enhanced fully automated approach is described for the protein isolation from soy flour samples by two-dimensional liquid chromatography with active modulation interface. The use of two multi-port switching valves is proposed to on-line connect the first to the second dimension column, thus overcoming the problems associated with the re-mixing effects and incompatibility of eluent composition and pH. A 5-cm long C4 analytical column installed in the interface device allows to focus the proteins coming from the first column (size exclusion chromatography), before their selective elution in the second column (reversed-phase). A trap washing step was included in the total workflow, as a desalting step to remove buffer residues from the eluent of the first column and to enhance the chromatographic performances of the second column. The experimental conditions were optimized by analyses of mixed standard solutions of bovine serum albumin, glucose oxidase, immunoglobulin A, thyroglobulin and myoglobin. Then, the optimized 2D-LC method was applied to the protein analysis in extracts of soy flour, known worldwide as one of the major food allergen sources, with the final aim to recovery sufficient protein amounts for the molecular characterization and the assessment of the pattern of allergenic components.
Collapse
Affiliation(s)
- Donatella Nardiello
- Dipartimento di Scienze Agrarie, degli Alimenti e dell'Ambiente, Università degli Studi di Foggia, Via Napoli, 25 - 71122 Foggia, Italy.
| | - Maria Teresa Melfi
- Dipartimento di Scienze Agrarie, degli Alimenti e dell'Ambiente, Università degli Studi di Foggia, Via Napoli, 25 - 71122 Foggia, Italy
| | - Carla Pignatelli
- Dipartimento di Scienze Agrarie, degli Alimenti e dell'Ambiente, Università degli Studi di Foggia, Via Napoli, 25 - 71122 Foggia, Italy
| | - Diego Centonze
- Dipartimento di Scienze Agrarie, degli Alimenti e dell'Ambiente, Università degli Studi di Foggia, Via Napoli, 25 - 71122 Foggia, Italy
| |
Collapse
|
29
|
Application of the new at-column dilution (ACD) modulator for the two-dimensional RP×HILIC analysis of Buddleja davidii. Anal Bioanal Chem 2020; 412:1483-1495. [PMID: 31965244 PMCID: PMC7026260 DOI: 10.1007/s00216-020-02392-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2019] [Revised: 12/04/2019] [Accepted: 01/07/2020] [Indexed: 02/06/2023]
Abstract
The focus of this study was the analysis of the complex chemical composition from different parts of Buddleja davidii, whose species are commonly known as ornamental plants and herbal medicines in many countries. As an herbal medicine, it has been utilized for stroke treatments, headache, wound healing, neurological disorder, etc. However, the understanding of its chemical matrices is still insufficient. Therefore, an online two-dimensional reversed phase liquid chromatography x hydrophilic interaction liquid chromatography (RPLCxHILIC) system coupled with mass spectrometry was applied for further detailed investigation of the chemical constituents in Buddleja dividii. In this two-dimensional liquid chromatography (2D-LC) method, a new at-column dilution (ACD) modulator was introduced in the 2D-LC system to solve the incompatibility problem of the mobile phase between two dimensions, which resulted in a 2D-LC analysis with high orthogonality. For the root extract, as one of the analyzed samples, the optimization of the 1D and 2D gradients was carried out carefully. With this new modulator, much better peak separation and better peak shape were achieved compared to two-dimensional liquid chromatography system using a traditional standard (TS) modulator. With a similar approach, the other four parts of Buddleja davidii were well separated. Comparing the different analyzed parts, flowers and leaves showed the most complex profiles. MS and MS/MS data were obtained successfully, which demonstrated the potential of the proposed RPLCxHILIC-MS system in the constituents’ analysis of herbal medicine. However, due to the lack of reported reference information, 24 compounds could be tentatively identified.
Collapse
|