1
|
Antipchik M, Reut J, Ayankojo AG, Öpik A, Syritski V. MIP-based electrochemical sensor for direct detection of hepatitis C virus via E2 envelope protein. Talanta 2022; 250:123737. [PMID: 35850055 DOI: 10.1016/j.talanta.2022.123737] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 07/07/2022] [Accepted: 07/11/2022] [Indexed: 02/07/2023]
Abstract
Hepatitis C is the most common liver disease caused by Hepatitis C virus (HCV), and can evolve into serious health problems e.g. cirrhosis and hepatocellular carcinoma. Nowadays, the initial stage of the disease cannot be practically diagnosed, representing thus an extremely important problem of modern public health care. This study is aimed at the development of a sensor for direct detection of HCV. The sensor utilizes a synthetic recognition element prepared by the technology of molecular imprinting and representing a molecularly imprinted polymer (MIP) having molecular recognition sites of HCV envelope protein E2 (E2-MIP). E2-MIP integrated into an electrochemical sensor platform allows quantitative evaluation of binding of free E2 protein as well as HCV-mimetic particles (HCV-MPs) in human plasma with LOD value of 4.6 × 10-4 ng/mL (for HCV-MPs). The developed electrochemical HCV sensor represents a simple, fast and inexpensive alternative for the existing methods of HCV detection and paves the way for the point-of care diagnostics of Hepatitis C.
Collapse
Affiliation(s)
- Mariia Antipchik
- Department of Materials and Environmental Technology, Tallinn University of Technology, Ehitajate tee 5, 19086 Tallinn, Estonia
| | - Jekaterina Reut
- Department of Materials and Environmental Technology, Tallinn University of Technology, Ehitajate tee 5, 19086 Tallinn, Estonia
| | - Akinrinade George Ayankojo
- Department of Materials and Environmental Technology, Tallinn University of Technology, Ehitajate tee 5, 19086 Tallinn, Estonia
| | - Andres Öpik
- Department of Materials and Environmental Technology, Tallinn University of Technology, Ehitajate tee 5, 19086 Tallinn, Estonia
| | - Vitali Syritski
- Department of Materials and Environmental Technology, Tallinn University of Technology, Ehitajate tee 5, 19086 Tallinn, Estonia.
| |
Collapse
|
2
|
Flores GL, Mota JC, da Silva Andrade LT, Lopes RS, Bastos FI, Villar LM. Performance of HCV Antigen Testing for the Diagnosis and Monitoring of Antiviral Treatment: A Systematic Review and Meta-Analysis. BIOMED RESEARCH INTERNATIONAL 2022; 2022:7348755. [PMID: 35028317 PMCID: PMC8752229 DOI: 10.1155/2022/7348755] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 11/21/2021] [Accepted: 12/01/2021] [Indexed: 12/11/2022]
Abstract
BACKGROUND AND AIMS Active hepatitis C virus (HCV) infection is based on the detection of HCV RNA that it is effective but presents high cost and the need to hire trained personnel. This systematic review and meta-analysis is aimed at evaluating the diagnostic accuracy of HCV Ag testing to identify HCV cases and to monitor antiviral treatment including DAA treatment. METHODS The studies were identified through a search in PubMed, Lilacs, and Scopus from 1990 through March 31, 2020. Cohort, cross-sectional, and randomized controlled trials were included. Two independent reviewers extracted data and assessed quality using an adapted Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Our primary outcome was to determine the accuracy of HCV Ag detection for the diagnosis, which we estimated using random-effects meta-analysis. RESULTS Of 3,062 articles identified, 54 met our eligibility criteria. The studies described cohorts from 20 countries, including 14,286 individuals with chronic HCV individuals. Studies for ECLIA technology demonstrated highest quality compared to studies that used ELISA. The pooled sensitivity and specificity (95% CI) for HCV Ag detection of active HCV infection were 98.82% (95%CI = 98.04%; 99.30%) and 98.95% (95%CI = 97.84%; 99.49%), respectively. High concordance was found between HCV Ag testing and HCV RNA detection 89.7% and 95% to evaluate antiviral treatment. CONCLUSIONS According to our findings, HCV Ag testing could be useful to identify HCV active cases in low-resource areas. For antiviral treatment, HCV Ag testing will be useful at the end of treatment.
Collapse
Affiliation(s)
- Geane Lopes Flores
- Laboratory of Viral Hepatitis, Oswaldo Cruz Institute, FIOCRUZ, Rio de Janeiro, Brazil
| | - Jurema Corrêa Mota
- Institute of Communication and Information on Science and Technology in Health, FIOCRUZ, Rio de Janeiro, Brazil
| | | | - Renata Serrano Lopes
- Laboratory of Viral Hepatitis, Oswaldo Cruz Institute, FIOCRUZ, Rio de Janeiro, Brazil
| | - Francisco Inácio Bastos
- Institute of Communication and Information on Science and Technology in Health, FIOCRUZ, Rio de Janeiro, Brazil
| | - Livia Melo Villar
- Laboratory of Viral Hepatitis, Oswaldo Cruz Institute, FIOCRUZ, Rio de Janeiro, Brazil
| |
Collapse
|
3
|
Bertisch B, Brezzi M, Negro F, Müllhaupt B, Ottiger C, Künzler-Heule P, Schmid P, Giudici F, Clerc O, Moriggia A, Roelens M, Marinucci F, Zehnder C, Moradpour D, Keiser O. Very Low Hepatitis C Viral Loads in Treatment-naive Persons: Do They Compromise Hepatitis C Virus Antigen Testing? Clin Infect Dis 2021; 70:653-659. [PMID: 30943286 DOI: 10.1093/cid/ciz270] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Accepted: 03/28/2019] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND Hepatitis C virus (HCV) antigen testing is less expensive than quantitative reverse-transcription polymerase chain reaction but has lower sensitivity for very low viral load (VLVL; HCV RNA ≤3000 IU/mL). Currently the benefits of antigen testing for screening are discussed, but data on prevalence and outcomes of persons with VLVL are scarce. METHODS We assessed prevalence and predictors of VLVL by logistic regression in treatment-naive participants in the Swiss Hepatitis C Cohort Study. We analyzed if the last viral load after VLVL was low, compared cirrhosis and mortality in persons with and without VLVL, and evaluated the number of samples with VLVL that were reactive by antigen testing. RESULTS We included 2533 treatment-naive persons with available quantitative HCV RNA testing results. Overall, 133 persons (5.3%) had a VLVL. Age 18-40 years, female sex, and human immunodeficiency virus coinfection were associated with VLVL. Of 72 persons with a viral load available after VLVL, 14% had a VLVL and 17% had spontaneous viral clearance. The prevalence and incidence of cirrhosis and mortality were comparable in persons with and without VLVL; all 24 persons with VLVL and cirrhosis had excessive alcohol consumption or immunosuppression. Overall, 33% of samples with VLVL were reactive by antigen testing. CONCLUSIONS The frequency of VLVL was low. Among the persons who would probably be missed by antigen screening, some had a favorable disease course, but some had immunosuppression and liver cirrhosis. The benefit of HCV antigen testing for screening may be limited by the risk of missing patients with severe liver disease.
Collapse
Affiliation(s)
| | - Matteo Brezzi
- Institute of Global Health, University of Geneva, Zürich
| | - Francesco Negro
- Divisions of Gastroenterology and Hepatology and of Clinical Pathology, University Hospitals Geneva, Zürich
| | - Beat Müllhaupt
- Swiss Hepato-Pancreato-Biliary Center and Department of Gastroenterology and Hepatology, University Hospital, Zürich
| | | | | | - Patrick Schmid
- Division of Infectious Diseases and Hospital Epidemiology, Cantonal Hospital St Gallen
| | - Fabio Giudici
- Institute of Social and Preventive Medicine, University of Bern
| | - Olivier Clerc
- Department of Internal Medicine and Infectious Diseases, Pourtalès Hospital, Neuchâtel
| | | | | | | | | | - Darius Moradpour
- Division of Gastroenterology and Hepatology, University Hospital Lausanne, Switzerland
| | - Olivia Keiser
- Institute of Global Health, University of Geneva, Zürich
| | | |
Collapse
|
4
|
Jülicher P, Galli C. Identifying cost-effective screening algorithms for active hepatitis C virus infections in a high prevalence setting. J Med Econ 2018; 21:1-10. [PMID: 28881157 DOI: 10.1080/13696998.2017.1369983] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
OBJECTIVE To evaluate the cost-effectiveness of different screening patterns for active chronic hepatitis C virus (HCV) infections utilizing the hepatitis C core antigen test compared to standard care in the context of a general screening program in a high-prevalence country. METHODS This study developed a decision analytic model to estimate the cost-effectiveness of four screening algorithms for the detection of active HCV infections among asymptomatic individuals with an unknown HCV status in a context of high (>5%) HCV prevalence. Three algorithms started with a serological test for antibodies (AB) followed by a nucleic acid test for HCV-RNA (RNA), the HCVAg (AG) assay, or both. An additional single marker screening strategy with AG was added to the analysis. By the example of the Republic of Georgia, strategies were compared in terms of total costs for screening and diagnosis of an active infection from a health system perspective. RESULTS Replacing RNA with AG for confirmation of positive AB identified fewer active infections (-110 per 100,000 screened subjects) at significantly reduced total costs (-$2.74 per screened) and costs per diagnosed infection (-$44). Adding a subsequent RNA confirmatory test on AG negative results captured at least the same rate compared to the standard (AB followed by RNA) at still reduced costs (-$1.16 per subject screened, -$22 per case detected). Utilizing AG as the frontline test revealed the highest detection rate (97.9%) at the highest costs (+$3.80 per subject, +$323 per case detected vs standard). CONCLUSION A combined pattern of HCV AB screening followed by sequential confirmation with AG and RNA on AG negatives would provide equal or better diagnostic performance at lower cost over a broad range of scenarios. Potential long-term consequences of screening strategies to patients and society have to be considered, since the latency period for HCV to develop into severe liver disease is long.
Collapse
Affiliation(s)
- Paul Jülicher
- a International Health Economics and Outcomes Research, Medical Affairs, Abbott Diagnostics , Wiesbaden , Germany
| | - Claudio Galli
- b Medical Scientific Liaison Europe, Abbott Diagnostics , Roma , Italy
| |
Collapse
|
5
|
Çetiner S, Çetin Duran A, Kibar F, Yaman A. Performance comparison of new generation HCV core antigen test versus HCV RNA test in management of hepatitis C virus infection. Transfus Apher Sci 2017; 56:362-366. [PMID: 28342642 DOI: 10.1016/j.transci.2017.02.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2016] [Revised: 02/03/2017] [Accepted: 02/22/2017] [Indexed: 12/28/2022]
Abstract
The study has evaluated the performance of HCV core antigen (Cag) test by comparing HCV RNA PCR assay which is considered the gold standard for management of HCV infection. Totally, 132 samples sent for HCV RNA (real-time PCR) test were included in the study. Anti-HCV antibody test and HCV Cag test were performed by chemiluminescent enzyme immunoassay (CMEI). Anti-HCV test was positive in all samples. HCV RNA was detected in 112/132 (84.8%) samples, and HCV Cag in 105/132 (79.5%). The most common HCV genotype was genotype 1 (86%). Considering the HCV RNA test as gold standard; the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of Cag test were found to be 93.75%, 100%, 100%, 74.07% and 94.69%, respectively, and paired test results were detected as highly concordant. A high level of correlation was seen between HCV RNA and Cag tests, however, the concordance between the two tests appeared to be disrupted at viral loads lower than 103IU/mL. On the contrary, the correlation reached significance for the values higher than 103IU/mL. Viral loads were in the 17-2500IU/mL range for the negative results for Cag test. Pearson's correlation coefficient revealed a considerably high correlation. The concordance between HCV RNA and Cag tests was disrupted under a viral load lower than 103IU/mL. Therefore, it would be appropriate to consider cost effectiveness, advantages and limitations of the HCV RNA and Cag tests during the decision on which method to use for patient management.
Collapse
Affiliation(s)
- Salih Çetiner
- Division of Basic Immunology, Balcali Hospital, Central Laboratory, Cukurova University, Adana, Turkey.
| | - Alev Çetin Duran
- Department of Medical Microbiology, Faculty of Medicine, Cukurova University, Adana, Turkey.
| | - Filiz Kibar
- Department of Medical Microbiology, Faculty of Medicine, Cukurova University, Adana, Turkey.
| | - Akgün Yaman
- Department of Medical Microbiology, Faculty of Medicine, Cukurova University, Adana, Turkey.
| |
Collapse
|
6
|
Can hepatitis C virus core antigen be used as a reliable marker of viral load for hepatitis C virus infection in genotype 4? EGYPTIAN LIVER JOURNAL 2017. [DOI: 10.1097/01.elx.0000523559.96944.09] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
|
7
|
Feng B, Yang RF, Xie Q, Shang J, Kong FY, Zhang HY, Rao HY, Jin Q, Cong X, Liu YY, Kang Y, Wei L. Hepatitis C virus core antigen, an earlier and stronger predictor on sustained virological response in patients with genotype 1 HCV infection. BMC Gastroenterol 2014; 14:47. [PMID: 24625322 PMCID: PMC3995626 DOI: 10.1186/1471-230x-14-47] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2013] [Accepted: 02/24/2014] [Indexed: 02/08/2023] Open
Abstract
Background Earlier kinetics of serum HCV core antigen (HCVcAg) and its predictive value on sustained virological response (SVR) were investigated in patients with genotype 1 HCV infection during antiviral treatment. Methods In a multi-centered, randomized and positive drug-controlled phase IIb clinical trial on type Y peginterferon α-2b (
NCT01140997), forty-eight CHC patients who participated in pharmacokinetics were randomly divided into 4 cohorts and treated with PegIFNα (type Y peginterferon α-2b 90 μg, 135 μg, 180 μg and PegIFNα-2a 180 μg, respectively, once a week) and ribavirin (< 75 kg, 1000 mg daily and ≥ 75 kg, 1200 mg daily) for 48 weeks, and then followed up for 24 weeks. 32 patients infected with genotype 1 HCV and completed the whole process were included in this study. HCV RNAs were detected at baseline, and weeks 4, 12, 24, 48 and 72 using Cobas TaqMan. ARCHITECT HCVcAg was performed at 24, 48, 72, 96, 120 and 144 h in addition to the above time points. The receiver operating curves (ROCs) were performed to study the predictive values of HCVcAg decline on SVR. Results Following antiviral treatment, serum HCVcAg levels rapidly declined within the first week and correlated well with corresponding HCV RNA at baseline, weeks 4, 12, 24, 48 and 72 (rs = 0.969, 0.928, 0.999, 0.983, 0.985 and 0.946, respectively, P < 0.001). All of the areas under the receiver operating curves (AUROCs) were more than 0.80 and showed good predictive power on SVR at 24, 48, 72, 96, 120 and 144 h. The144 h was the best predictive time point of HCVcAg decline on SVR because of its largest AUROC (more than 0.90). Conclusions Early kinetics of serum HCVcAg predicts SVR very well in genotype 1 CHC patients during antiviral treatment, and its reduction value at 144 h is an earlier and stronger predictor on SVR than rapid virological response and early virological response. (TRN:
NCT01140997).
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | - Lai Wei
- Peking University People's Hospital, Peking University Hepatology Institute, Beijing Key Laboratory of Hepatitis C and Immunotherapy for Liver Diseases, Beijing, PR China.
| |
Collapse
|
8
|
Abstract
HCV is a blood-borne virus transmitted by percutaneous exposure to infected blood or blood-derived body fluids. The main routes of transmission are blood transfusions, medical procedures and injection drug use. In industrialized countries, HCV transmission through blood transfusions has been virtually eliminated and iatrogenic transmission occurs only sporadically during local breaches of infection control procedures. As most new cases originate from injection drug use, harm-reduction programmes (including opiate substitution, needle exchange and health education) can greatly reduce HCV transmission. Currently, the main approach to reduce the HCV disease burden is by increasing awareness of both the public and health-care providers to hepatitis C, enhancing screening opportunities and treatment of the infected population. In resource-limited countries, the priority is reducing transmission through blood transfusions and invasive medical procedures. This approach requires training of health-care providers and also structural changes and financial investments in countries where antibody screening, disposable materials and effective sterilization procedures are not routinely available. In these countries, reducing the HCV burden has been hampered by limited access to treatment, largely owing to the cost of drugs. Access to treatment is moving up on the agenda of international and non-governmental organizations in conjunction with the future availability of highly efficacious oral drug regimens.
Collapse
|