1
|
Chen M, Ye M, Wang Z, Hu C, Liu T, Liu K, Shi J, Zhang X. Electrically addressed focal stack plenoptic camera based on a liquid-crystal microlens array for all-in-focus imaging. OPTICS EXPRESS 2022; 30:34938-34955. [PMID: 36242498 DOI: 10.1364/oe.465683] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 08/28/2022] [Indexed: 06/16/2023]
Abstract
Focal stack cameras are capable of capturing a stack of images focused at different spatial distance, which can be further integrated to present a depth of field (DoF) effect beyond the range restriction of conventional camera's optics. To date, all of the proposed focal stack cameras are essentially 2D imaging architecture to shape 2D focal stacks with several selected focal lengths corresponding to limited objective distance range. In this paper, a new type of electrically addressed focal stack plenoptic camera (EAFSPC) based on a functional liquid-crystal microlens array for all-in-focus imaging is proposed. As a 3D focal stack camera, a sequence of raw light-field images can be rapidly manipulated through rapidly shaping a 3D focal stack. The electrically addressed focal stack strategy relies on the electric tuning of the focal length of the liquid-crystal microlens array by efficiently selecting or adjusting or jumping the signal voltage applied over the microlenses. An algorithm based on the Laplacian operator is utilized to composite the electrically addressed focal stack leading to raw light-field images with an extended DoF and then the all-in-focus refocused images. The proposed strategy does not require any macroscopic movement of the optical apparatus, so as to thoroughly avoid the registration of different image sequence. Experiments demonstrate that the DoF of the refocused images can be significantly extended into the entire tomography depth of the EAFSPC, which means a significant step for an all-in-focus imaging based on the electrically controlled 3D focal stack. Moreover, the proposed approach also establishes a high correlation between the voltage signal and the depth of in-focus plane, so as to construct a technical basis for a new type of 3D light-field imaging with an obvious intelligent feature.
Collapse
|
2
|
Xing Z, Xu Z, Zhang X, Chen B, Guo Z, Wang J, Wang Y, Tai R. Virtual depth-scan multi-slice ptychography for improved three-dimensional imaging. OPTICS EXPRESS 2021; 29:16214-16227. [PMID: 34154189 DOI: 10.1364/oe.422214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Accepted: 04/02/2021] [Indexed: 06/13/2023]
Abstract
Multi-slice ptychography (MSP) is a fast three-dimensional ptychography technology developed on the basis of conventional ptychography. With this method, three-dimensional imaging can be achieved without rotating the sample. The prototype multi-slice algorithm can only reconstruct three-dimensional samples with a limited number of slices, which greatly limits the depth range and resolution of sample imaging. Here we reported a virtual depth-scan scheme of MSP in which a thick sample is scanned virtually in the depth direction across its whole thickness range within the reconstruction process, thereby eliminating the restriction on slice number and potentially improving the depth resolution of MSP. This new approach also improves the flexibility of multi-slice ptychography. Both the simulation and experimental results validate the feasibility of our new approach.
Collapse
|
3
|
Witte K, Späth A, Finizio S, Donnelly C, Watts B, Sarafimov B, Odstrcil M, Guizar-Sicairos M, Holler M, Fink RH, Raabe J. From 2D STXM to 3D Imaging: Soft X-ray Laminography of Thin Specimens. NANO LETTERS 2020; 20:1305-1314. [PMID: 31951418 DOI: 10.1021/acs.nanolett.9b04782] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
X-ray tomography has become an indispensable tool for studying complex 3D interior structures with high spatial resolution. Three-dimensional imaging using soft X-rays offers powerful contrast mechanisms but has seen limited success with tomography due to the restrictions imposed by the much lower energy of the probe beam. The generalized geometry of laminography, characterized by a tilted axis of rotation, provides nm-scale 3D resolution for the investigation of extended (mm range) but thin (μm to nm) samples that are well suited to soft X-ray studies. This work reports on the implementation of soft X-ray laminography (SoXL) at the scanning transmission X-ray spectromicroscope of the PolLux beamline at the Swiss Light Source, Paul Scherrer Institut, which enables 3D imaging of extended specimens from 270 to 1500 eV. Soft X-ray imaging provides contrast mechanisms for both chemical sensitivity to molecular bonds and oxidation states and magnetic dichroism due to the much stronger attenuation of X-rays in this energy range. The presented examples of applications range from functionalized nanomaterials to biological photonic crystals and sophisticated nanoscaled magnetic domain patterns, thus illustrating the wide fields of research that can benefit from SoXL.
Collapse
Affiliation(s)
- Katharina Witte
- Swiss Light Source , Paul Scherrer Institut , Forschungsstrasse 111 , 5232 Villigen , Switzerland
| | - Andreas Späth
- Department Chemie und Pharmazie, Physikalische Chemie , Friedrich-Alexander-Universität Erlangen-Nürnberg , Egerlandstrasse 3 , 91058 Erlangen , Germany
| | - Simone Finizio
- Swiss Light Source , Paul Scherrer Institut , Forschungsstrasse 111 , 5232 Villigen , Switzerland
| | - Claire Donnelly
- Cavendish Laboratory , University of Cambridge , JJ Thomson Avenue , Cambridge , CB3 0HE , United Kingdom
| | - Benjamin Watts
- Swiss Light Source , Paul Scherrer Institut , Forschungsstrasse 111 , 5232 Villigen , Switzerland
| | - Blagoj Sarafimov
- Swiss Light Source , Paul Scherrer Institut , Forschungsstrasse 111 , 5232 Villigen , Switzerland
| | - Michal Odstrcil
- Swiss Light Source , Paul Scherrer Institut , Forschungsstrasse 111 , 5232 Villigen , Switzerland
| | - Manuel Guizar-Sicairos
- Swiss Light Source , Paul Scherrer Institut , Forschungsstrasse 111 , 5232 Villigen , Switzerland
| | - Mirko Holler
- Swiss Light Source , Paul Scherrer Institut , Forschungsstrasse 111 , 5232 Villigen , Switzerland
| | - Rainer H Fink
- Department Chemie und Pharmazie, Physikalische Chemie , Friedrich-Alexander-Universität Erlangen-Nürnberg , Egerlandstrasse 3 , 91058 Erlangen , Germany
| | - Jörg Raabe
- Swiss Light Source , Paul Scherrer Institut , Forschungsstrasse 111 , 5232 Villigen , Switzerland
| |
Collapse
|
4
|
Späth A. Additive Nano-Lithography with Focused Soft X-rays: Basics, Challenges, and Opportunities. MICROMACHINES 2019; 10:E834. [PMID: 31801198 PMCID: PMC6953100 DOI: 10.3390/mi10120834] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2019] [Revised: 11/27/2019] [Accepted: 11/29/2019] [Indexed: 12/18/2022]
Abstract
Focused soft X-ray beam induced deposition (FXBID) is a novel technique for direct-write nanofabrication of metallic nanostructures from metal organic precursor gases. It combines the established concepts of focused electron beam induced processing (FEBIP) and X-ray lithography (XRL). The present setup is based on a scanning transmission X-ray microscope (STXM) equipped with a gas flow cell to provide metal organic precursor molecules towards the intended deposition zone. Fundamentals of X-ray microscopy instrumentation and X-ray radiation chemistry relevant for FXBID development are presented in a comprehensive form. Recently published proof-of-concept studies on initial experiments on FXBID nanolithography are reviewed for an overview on current progress and proposed advances of nanofabrication performance. Potential applications and advantages of FXBID are discussed with respect to competing electron/ion based techniques.
Collapse
Affiliation(s)
- Andreas Späth
- Friedrich-Alexander-University Erlangen-Nuremberg, Physical Chemistry II, Egerlandstraße 3, 91058 Erlangen, Germany
| |
Collapse
|
5
|
Ma L, Xu Z, Zhang X, Lin J, Tai R. Facile and quick formation of cellulose nanopaper with nanoparticles and its characterization. Carbohydr Polym 2019; 221:195-201. [DOI: 10.1016/j.carbpol.2019.06.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Revised: 06/01/2019] [Accepted: 06/05/2019] [Indexed: 11/15/2022]
|
6
|
Malyshev IV, Chkhalo NI. A method of z-tomography using high-aperture soft X-ray microscopy. Ultramicroscopy 2019; 202:76-86. [PMID: 31003162 DOI: 10.1016/j.ultramic.2019.04.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Revised: 02/19/2019] [Accepted: 04/10/2019] [Indexed: 11/25/2022]
Abstract
Multilayer normal-incidence mirrors allow the numerical aperture (NA=0.3-0.5) of a projection lens to be significantly increased in the spectral ranges of the water (λ = 2.3-4.4 nm) and carbon (λ = 4.4-7 nm) windows, in comparison with the Fresnel zone plates. The low depth of focus of high-aperture optics (tens of nm) makes it possible to use z-tomography to reconstruct the structure of samples in soft X-ray microscopy. The presence of strong absorption prevents the direct use of a powerful deconvolution apparatus developed for fluorescence optical microscopy to improve the clarity of the image. In this article, the "intensity restoration algorithm" is proposed that takes into account the absorption effect before standard deconvolution. For an imagine lens with NA = 0.3 and a working wavelength of 3.37 nm, the results of simulating an image of a protein cell and its deconvolutionary processing are presented, before and after applying the proposed method. After its application, the deconvolution efficiency is significantly increased. A "full-period" resolution of 40 nm was obtained for the image of a simulated protein cell.
Collapse
Affiliation(s)
- Ilya V Malyshev
- Institute for Physics of Microstructures of RAS, GSP-105, 603950 Nizhny Novgorod, Russia.
| | - Nikolay I Chkhalo
- Institute for Physics of Microstructures of RAS, GSP-105, 603950 Nizhny Novgorod, Russia
| |
Collapse
|
7
|
Ma L, Zhang X, Xu Z, Späth A, Xing Z, Sun T, Tai R. Three-dimensional focal stack imaging in scanning transmission X-ray microscopy with an improved reconstruction algorithm. OPTICS EXPRESS 2019; 27:7787-7802. [PMID: 30876336 DOI: 10.1364/oe.27.007787] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2018] [Accepted: 01/25/2019] [Indexed: 06/09/2023]
Abstract
Focal stack (FS) is an effective technique for fast 3D imaging in high-resolution scanning transmission X-ray microscopy. Its crucial issue is to assign each object within the sample to the correct position along the optical axis according to a proper focus measure. There is probably information loss with previous algorithms for FS reconstruction because the old algorithms can only detect one focused object along each optical-axial pixel line (OAPL). In this study, we present an improved FS algorithm, which utilizes an elaborately calculated threshold for normalized local variances to extract multiple focused objects in each OAPL. Simulation and experimental results show its feasibility and high efficiency for 3D imaging of high contrast, sparse samples. It is expected that our advanced approach has potential applications in 3D X-ray microscopy for more complex samples.
Collapse
|
8
|
Zhang P, Chen YP, Qiu JH, Dai YZ, Feng B. Imaging the Microprocesses in Biofilm Matrices. Trends Biotechnol 2018; 37:214-226. [PMID: 30075862 DOI: 10.1016/j.tibtech.2018.07.006] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 07/07/2018] [Accepted: 07/09/2018] [Indexed: 12/22/2022]
Abstract
Biofilms, which are aggregates of microorganisms and extracellular matrices, widely colonize natural water bodies, wastewater treatment systems, and body tissues, and have vital roles in water purification, biofouling, and infectious diseases. Recently, multiple imaging modalities have been developed to visualize the morphological structure and material distribution within biofilms and to probe the microprocesses in biofilm matrices, including biofilm formation, transfer and metabolism of substrates, and cell-cell communication. These technologies have improved our understanding of biofilm control and the fates of substrates in biofilms. In this review, we describe the principles of various imaging techniques and discuss the advantages and limitations of each approach to characterizing microprocesses in biofilm matrices.
Collapse
Affiliation(s)
- Peng Zhang
- College of Environment and Resources, Xiangtan University, Xiangtan, 411105, China; Key Laboratory of the Three Gorges Reservoir Region's Eco-Environments of MOE, Chongqing University, Chongqing 400045, China
| | - You-Peng Chen
- Key Laboratory of the Three Gorges Reservoir Region's Eco-Environments of MOE, Chongqing University, Chongqing 400045, China.
| | - Ju-Hui Qiu
- College of Bioengineering, Chongqing University, Chongqing 400045, China
| | - You-Zhi Dai
- College of Environment and Resources, Xiangtan University, Xiangtan, 411105, China
| | - Bo Feng
- College of Environment and Resources, Xiangtan University, Xiangtan, 411105, China.
| |
Collapse
|
9
|
Späth A, Graf-Zeiler BA, Paradossi G, Ghugare S, Tzvetkov G, Fink RH. Quantitative X-ray microscopic analysis of individual thermoresponsive microgel particles in aqueous solution. RSC Adv 2016. [DOI: 10.1039/c6ra20142c] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
The temperature dependent phase transition of individual thermoresponsive microgel particles in aqueous solution has been studied by high resolution soft X-ray transmission microscopy (STXM).
Collapse
Affiliation(s)
- Andreas Späth
- Physikalische Chemie II
- ICMM
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU)
- 91058 Erlangen
- Germany
| | - Birgit A. Graf-Zeiler
- Physikalische Chemie II
- ICMM
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU)
- 91058 Erlangen
- Germany
| | - Gaio Paradossi
- Dipartimento di Scienze e Tecnologie Chimiche
- Università di Roma Tor Vergata
- 00133 Roma
- Italy
| | - Shivkumar Ghugare
- Dipartimento di Scienze e Tecnologie Chimiche
- Università di Roma Tor Vergata
- 00133 Roma
- Italy
| | - George Tzvetkov
- Department of Inorganic Chemistry
- Faculty of Chemistry
- University of Sofia
- 1164 Sofia
- Bulgaria
| | - Rainer H. Fink
- Physikalische Chemie II
- ICMM
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU)
- 91058 Erlangen
- Germany
| |
Collapse
|
10
|
Cai S, Zeng C, Zhang N, Li J, Meyer M, Fink RH, Shi D, Ren J. Enhanced mechanical properties of PLA/PLAE blends via well-dispersed and compatilized nanostructures in the matrix. RSC Adv 2016. [DOI: 10.1039/c6ra01367h] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
The mechanical properties of PLA are significantly enhanced by the well-dispersed and compatilized nanostructures in the matrix of PLA/PLAE blends.
Collapse
Affiliation(s)
- Shenyang Cai
- Institute of Nano- and Bio-polymeric Materials
- Key Laboratory of Advanced Civil Engineering Materials of Ministry of Education
- School of Material Science and Engineering
- Tongji University
- Shanghai 201804
| | - Chao Zeng
- Institute of Nano- and Bio-polymeric Materials
- Key Laboratory of Advanced Civil Engineering Materials of Ministry of Education
- School of Material Science and Engineering
- Tongji University
- Shanghai 201804
| | - Naiwen Zhang
- Shanghai Tong-jie-liang Biomaterials Co., Ltd
- Shanghai 200438
- China
| | - Jianbo Li
- Institute of Nano- and Bio-polymeric Materials
- Key Laboratory of Advanced Civil Engineering Materials of Ministry of Education
- School of Material Science and Engineering
- Tongji University
- Shanghai 201804
| | - Markus Meyer
- Physikalische Chemie II
- Friedrich-Alexander Universität Erlangen-Nürnberg (FAU)
- Erlangen
- Germany
| | - Rainer H. Fink
- Physikalische Chemie II
- Friedrich-Alexander Universität Erlangen-Nürnberg (FAU)
- Erlangen
- Germany
| | - Donglu Shi
- Shanghai East Hospital
- The Institute for Biomedical Engineering and Nano Science
- Tongji University School of Medicine
- Shanghai 200120
- China
| | - Jie Ren
- Institute of Nano- and Bio-polymeric Materials
- Key Laboratory of Advanced Civil Engineering Materials of Ministry of Education
- School of Material Science and Engineering
- Tongji University
- Shanghai 201804
| |
Collapse
|
11
|
Wang YF, Wang CY, Wan P, Wang SG, Wang XM. Comparison of bone regeneration in alveolar bone of dogs on mineralized collagen grafts with two composition ratios of nano-hydroxyapatite and collagen. Regen Biomater 2015; 3:33-40. [PMID: 26816654 PMCID: PMC4723277 DOI: 10.1093/rb/rbv025] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2015] [Revised: 11/11/2015] [Accepted: 11/12/2015] [Indexed: 02/04/2023] Open
Abstract
To study the effect of two composition ratios of nano-hydroxyapatite and collagen (NHAC) composites on repairing alveolar bone defect of dogs. Eighteen healthy adult dogs were randomly divided into three groups. Two kinds of the NHAC composites were prepared according to the constituent ratios of 3:7 and 5:5; immediately after extraction of the mandibular second premolars, each kind of the NHAC composite was implanted into extraction socket, respectively: Group I, nHA/Col = 3:7; Group II, nHA/Col = 5:5 and Group III, blank control group. The bone-repairing ability of the two grafts was separately analyzed by morphometric measurement, X-ray tomography examination and biomechanical analysis at 1st, 3rd and 6th month post-surgical, respectively. The NHAC composites were absorbed gradually after implanting into alveolar bone defect and were replaced by new bone. The ratios of new bone formation of Group I was significantly higher than that of Group II after 3 months (P < 0.05). The structure and bioactive performance can be improved when the ratio between the collagen and the hydroxyapatite was reasonable, and the repairing ability and effect in extraction sockets are obviously better.
Collapse
Affiliation(s)
- Yan-Fu Wang
- Graduate School, Liaoning Medical University, Jinzhou 121000, China
| | - Cheng-Yue Wang
- Department of Prosthodontics, Affiliated Stomatological Hospital of Liaoning Medical University, Jinzhou 121000, China
| | - Peng Wan
- Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
| | - Shao-Gang Wang
- Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
| | - Xiu-Mei Wang
- Institute for Regenerative Medicine and Biomimetic Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China
| |
Collapse
|