1
|
Noninvasive Spectroscopic Detection of Blood Glucose and Analysis of Clinical Research Status. JOURNAL OF HEALTHCARE ENGINEERING 2022; 2022:8325451. [PMID: 35178236 PMCID: PMC8844100 DOI: 10.1155/2022/8325451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 12/20/2021] [Accepted: 01/13/2022] [Indexed: 11/18/2022]
Abstract
Frequent measurement of blood glucose concentration in diabetic patients is an important means for diabetes control. Blood glucose monitoring with noninvasive detection technology can not only avoid the pain of patients and eliminate the harm of some biological materials for measuring glucose in vivo but also improve the frequency of detection, so as to control blood glucose concentration more closely. Traditional blood glucose detection methods are invasive and have some limitations. In this study, the significance of noninvasive blood glucose testing was analyzed and was pointed out that noninvasive blood glucose testing can monitor the blood glucose concentration of patients and relieve the pain of patients. Then, this study analyzed the spectral detection methods of noninvasive blood glucose, including conservation of energy metabolism, near infrared spectroscopy, and other spectral detection methods. Finally, this study made a comprehensive analysis of the domestic and international clinical application of noninvasive glucose spectrum monitoring and summarized the clinical application status of noninvasive glucose spectrum monitoring.
Collapse
|
2
|
Bungart B, Cao Y, Yang-Tran T, Gorsky S, Lan L, Roblyer D, Koch MO, Cheng L, Masterson T, Cheng JX. Cylindrical illumination with angular coupling for whole-prostate photoacoustic tomography. BIOMEDICAL OPTICS EXPRESS 2019; 10:1405-1419. [PMID: 30891355 PMCID: PMC6420282 DOI: 10.1364/boe.10.001405] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Revised: 02/07/2019] [Accepted: 02/07/2019] [Indexed: 05/20/2023]
Abstract
Current diagnosis of prostate cancer relies on histological analysis of tissue samples acquired by biopsy, which could benefit from real-time identification of suspicious lesions. Photoacoustic tomography has the potential to provide real-time targets for prostate biopsy guidance with chemical selectivity, but light delivered from the rectal cavity has been unable to penetrate to the anterior prostate. To overcome this barrier, a urethral device with cylindrical illumination is developed for whole-prostate imaging, and its performance as a function of angular light coupling is evaluated with a prostate-mimicking phantom.
Collapse
Affiliation(s)
- Brittani Bungart
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, West Lafayette, IN 47907, USA
- Medical Scientist Training Program, Indiana University School of Medicine, 635 Barnhill Drive MS 2031, Indianapolis, IN 46202, USA
- Department of Electrical and Computer Engineering, Boston University, 8 St. Mary’s Street, Boston, MA 02215, USA
| | - Yingchun Cao
- Department of Electrical and Computer Engineering, Boston University, 8 St. Mary’s Street, Boston, MA 02215, USA
| | - Tiffany Yang-Tran
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215, USA
| | - Sean Gorsky
- Department of Electrical and Computer Engineering, Boston University, 8 St. Mary’s Street, Boston, MA 02215, USA
| | - Lu Lan
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215, USA
| | - Darren Roblyer
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215, USA
| | - Michael O. Koch
- Department of Urology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Liang Cheng
- Department of Pathology and Laboratory Medicine, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Timothy Masterson
- Department of Urology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Ji-Xin Cheng
- Department of Electrical and Computer Engineering, Boston University, 8 St. Mary’s Street, Boston, MA 02215, USA
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215, USA
| |
Collapse
|
3
|
James J, Murukeshan VM, Woh LS. Integrated photoacoustic, ultrasound and fluorescence platform for diagnostic medical imaging-proof of concept study with a tissue mimicking phantom. BIOMEDICAL OPTICS EXPRESS 2014; 5:2135-44. [PMID: 25071954 PMCID: PMC4102354 DOI: 10.1364/boe.5.002135] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2014] [Revised: 04/29/2014] [Accepted: 05/07/2014] [Indexed: 05/03/2023]
Abstract
The structural and molecular heterogeneities of biological tissues demand the interrogation of the samples with multiple energy sources and provide visualization capabilities at varying spatial resolution and depth scales for obtaining complementary diagnostic information. A novel multi-modal imaging approach that uses optical and acoustic energies to perform photoacoustic, ultrasound and fluorescence imaging at multiple resolution scales from the tissue surface and depth is proposed in this paper. The system comprises of two distinct forms of hardware level integration so as to have an integrated imaging system under a single instrumentation set-up. The experimental studies show that the system is capable of mapping high resolution fluorescence signatures from the surface, optical absorption and acoustic heterogeneities along the depth (>2cm) of the tissue at multi-scale resolution (<1µm to <0.5mm).
Collapse
Affiliation(s)
- Joseph James
- The Centre for Optical and Lasers in Engineering (COLE), School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798, Singapore
| | - Vadakke Matham Murukeshan
- The Centre for Optical and Lasers in Engineering (COLE), School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798, Singapore
| | - Lye Sun Woh
- The Centre for Optical and Lasers in Engineering (COLE), School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798, Singapore
| |
Collapse
|
4
|
Zackrisson S, van de Ven SMWY, Gambhir SS. Light in and sound out: emerging translational strategies for photoacoustic imaging. Cancer Res 2014; 74:979-1004. [PMID: 24514041 DOI: 10.1158/0008-5472.can-13-2387] [Citation(s) in RCA: 323] [Impact Index Per Article: 29.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Photoacoustic imaging (PAI) has the potential for real-time molecular imaging at high resolution and deep inside the tissue, using nonionizing radiation and not necessarily depending on exogenous imaging agents, making this technique very promising for a range of clinical applications. The fact that PAI systems can be made portable and compatible with existing imaging technologies favors clinical translation even more. The breadth of clinical applications in which photoacoustics could play a valuable role include: noninvasive imaging of the breast, sentinel lymph nodes, skin, thyroid, eye, prostate (transrectal), and ovaries (transvaginal); minimally invasive endoscopic imaging of gastrointestinal tract, bladder, and circulating tumor cells (in vivo flow cytometry); and intraoperative imaging for assessment of tumor margins and (lymph node) metastases. In this review, we describe the basics of PAI and its recent advances in biomedical research, followed by a discussion of strategies for clinical translation of the technique.
Collapse
Affiliation(s)
- S Zackrisson
- Departments of Radiology, Bioengineering, and Department of Materials Science & Engineering. Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA.,Diagnostic Radiology, Department of Clinical Sciences in Malmö, Lund University, Sweden
| | - S M W Y van de Ven
- Departments of Radiology, Bioengineering, and Department of Materials Science & Engineering. Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA
| | - S S Gambhir
- Departments of Radiology, Bioengineering, and Department of Materials Science & Engineering. Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA
| |
Collapse
|
5
|
Roggenbuck MA, Walker RD, Catenacci JW, Patch SK. Volumetric thermoacoustic imaging over large fields of view. ULTRASONIC IMAGING 2013; 35:57-67. [PMID: 23287507 DOI: 10.1177/0161734612471664] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The thermoacoustic (TA) contrast mechanism relies on rapid tissue heating and subsequent thermal expansion. TA computerized tomography (TCT) is therefore inverse source imaging. The TA contrast mechanism provides information complementary to that revealed by current diagnostic imaging techniques, but has been limited to just a few centimeters depth penetration. In this article, whole organ TCT is demonstrated on a large swine kidney. TA sinograms show that TA signal generated by high-power, very high frequency (VHF) electromagnetic pulses is detectable after travel through 6 cm of soft tissue. Reconstructed images provide resolution sufficient to track progression of calyces throughout the kidney. Because VHF electromagnetic energy can easily penetrate the abdomen of large adults, our results indicate that whole organ TA imaging is feasible in vivo, provided an ultrasound array can be placed near the region of interest. Pulses of 22 to 25 kW with carrier frequency 108 MHz and 900 ns pulse width were applied at a 100-Hz pulse repetition frequency to generate a 13-kV/m electric field and TA signal. Only 2 to 5 mJ was absorbed in the kidney per pulse, causing temperature and pressure jumps of only 5e-6°C and 4 Pa averaged throughout the 141-g specimen. TA pulses were detected by focused, single-element transducers (V306, Panametrics), amplified by 54 dB and averaged 64 times to reduce electronic noise. Data were measured over a cylindrical measurement aperture of radius 5 cm and length 6 cm, by rotating the specimen 1.8 degrees between tomographic views and translating 2 mm between slices. Reconstruction via filtered backprojection yields in-plane resolution better than 5 mm, but suffers significant blurring between planes. Both in-plane resolution and slice sensitivity profile could be improved by applying shorter irradiation pulsewidths and using less directional transducers. Both hardware changes would be recommended for a clinical prototype.
Collapse
|
6
|
An RR, Luo XS, Shen ZH. Numerical simulation of the influence of the elastic modulus of a tumor on laser-induced ultrasonics in soft tissue. APPLIED OPTICS 2012; 51:7869-7876. [PMID: 23142902 DOI: 10.1364/ao.51.007869] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2012] [Accepted: 10/16/2012] [Indexed: 06/01/2023]
Abstract
The influence of the elastic modulus of a tumor (EMT) on the laser-generated thermoelastic force source and ultrasound waves are investigated by using the finite element method. Taking into account the effects of thermal diffusion, optical penetration, and finite duration of laser pulse, the transient temperature distribution is obtained. Applying this temperature field to structure analyses as thermal loading, the thermoelastic stress field and laser-induced ultrasound wave in soft tissues are obtained. The results show that there is a linear correlation between the maximum compressive stress and the elastic modulus of tissues. It is also shown that the features and frequency regions of the laser-induced ultrasound waveform have a close relationship with the EMT, which has been further verified by a corresponding experiment.
Collapse
Affiliation(s)
- Rong Rong An
- School of Science, Nanjing University of Science and Technology, Nanjing, China
| | | | | |
Collapse
|