Poudrel AS, Bouffandeau A, Demeet OL, Rosi G, Nguyen VH, Haiat G. Characterization of the concentration of agar-based soft tissue mimicking phantoms by impact analysis. J Mech Behav Biomed Mater 2024; 152:106465. [PMID: 38377641 DOI: 10.1016/j.jmbbm.2024.106465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2023] [Revised: 01/14/2024] [Accepted: 02/13/2024] [Indexed: 02/22/2024]
Abstract
In various medical fields, a change of soft tissue stiffness is associated with its physio-pathological evolution. While elastography is extensively employed to assess soft tissue stiffness in vivo, its application requires a complex and expensive technology. The aim of this study is to determine whether an easy-to-use method based on impact analysis can be employed to determine the concentration of agar-based soft tissue mimicking phantoms. Impact analysis was performed on soft tissue mimicking phantoms made of agar gel with a mass concentration ranging from 1% to 5%. An indicator Δt is derived from the temporal variation of the impact force signal between the hammer and a small beam in contact with the sample. The results show a non-linear decrease of Δt as a function of the agar concentration (and thus of the sample stiffness). The value of Δt provides an estimation of the agar concentration with an error of 0.11%. This sensitivity of the impact analysis based method to the agar concentration is of the same order of magnitude than results obtained with elastography techniques. This study opens new paths towards the development of impact analysis for a fast, easy and relatively inexpensive clinical evaluation of soft tissue elastic properties.
Collapse
Affiliation(s)
- Anne-Sophie Poudrel
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010 Créteil, France
| | - Arthur Bouffandeau
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010 Créteil, France
| | - Oriane Le Demeet
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010 Créteil, France
| | - Giuseppe Rosi
- Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, UMR 8208, MSME, F-94010 Créteil, France
| | - Vu-Hieu Nguyen
- Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, UMR 8208, MSME, F-94010 Créteil, France
| | - Guillaume Haiat
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010 Créteil, France.
| |
Collapse
|
2
|
Selladurai S, Verma A, Thittai AK. Toward Quantitative and Operator-independent Quasi-static Ultrasound Elastography: An Ex Vivo Feasibility Study. ULTRASONIC IMAGING 2020; 42:179-190. [PMID: 32450766 DOI: 10.1177/0161734620921532] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
It is known that the elasticity of liver reduces progressively in the case of diffuse liver disease. Currently, the diagnosis of diffuse liver disease requires a biopsy, which is an invasive procedure. In this paper, we evaluate and report a noninvasive method that can be used to quantify liver stiffness using quasi-static ultrasound elastography approach. Quasi-static elastography is popular in clinical applications where the qualitative assessment of relative tissue stiffness is enough, whereas its potential is relatively underutilized in liver imaging due to lack of local stiffness contrast in the case of diffuse liver disease. Recently, we demonstrated an approach of using a calibrated reference layer to produce quantitative modulus elastograms of the target tissue in simulations and phantom experiments. In a separate work, we reported the development of a compact handheld device to reduce inter- and intraoperator variability in freehand elastography. In this work, we have integrated the reference layer with a handheld controlled compression device and evaluate it for quantitative liver stiffness imaging application. The performance of this technique was assessed on ex vivo goat liver samples. The Young's modulus values obtained from indentation measurements of liver samples acted as the ground truth for comparison. The results from this work demonstrate that by combining the handheld device along with reference layer, the estimated Young's modulus value approaches the ground truth with less error compared with that obtained using freehand compression (8% vs. 15%). The results suggest that the intra- and interoperator reproducibility of the liver elasticity also improved when using the handheld device. Elastography with a handheld compression device and reference layer is a reliable and simple technique to provide a quantitative measure of elasticity.
Collapse
Affiliation(s)
- Sathiyamoorthy Selladurai
- Biomedical Ultrasound Laboratory, Biomedical Engineering Group, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai, India
| | - Abhilash Verma
- Biomedical Ultrasound Laboratory, Biomedical Engineering Group, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai, India
| | - Arun K Thittai
- Biomedical Ultrasound Laboratory, Biomedical Engineering Group, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai, India
| |
Collapse
|
3
|
A Mechatronic Platform for Computer Aided Detection of Nodules in Anatomopathological Analyses via Stiffness and Ultrasound Measurements. SENSORS 2019; 19:s19112512. [PMID: 31159334 PMCID: PMC6603638 DOI: 10.3390/s19112512] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2019] [Revised: 05/11/2019] [Accepted: 05/29/2019] [Indexed: 11/17/2022]
Abstract
This study presents a platform for ex-vivo detection of cancer nodules, addressing automation of medical diagnoses in surgery and associated histological analyses. The proposed approach takes advantage of the property of cancer to alter the mechanical and acoustical properties of tissues, because of changes in stiffness and density. A force sensor and an ultrasound probe were combined to detect such alterations during force-regulated indentations. To explore the specimens, regardless of their orientation and shape, a scanned area of the test sample was defined using shape recognition applying optical background subtraction to the images captured by a camera. The motorized platform was validated using seven phantom tissues, simulating the mechanical and acoustical properties of ex-vivo diseased tissues, including stiffer nodules that can be encountered in pathological conditions during histological analyses. Results demonstrated the platform’s ability to automatically explore and identify the inclusions in the phantom. Overall, the system was able to correctly identify up to 90.3% of the inclusions by means of stiffness in combination with ultrasound measurements, paving pathways towards robotic palpation during intraoperative examinations.
Collapse
|
4
|
Selladurai S, Thittai AK. Towards quantitative quasi-static ultrasound elastography using a reference layer for liver imaging application: A preliminary assessment. ULTRASONICS 2019; 93:7-17. [PMID: 30384008 DOI: 10.1016/j.ultras.2018.10.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2018] [Revised: 09/17/2018] [Accepted: 10/16/2018] [Indexed: 06/08/2023]
Abstract
Changes in tissue elasticity are generally correlated with pathological phenomena. For example, diffuse liver disease progressively reduces the elasticity of the liver. Quasi-static elastography is popular in clinical applications to visualize regions with different relative stiffness. However, the limitation of this technique is that it provides only qualitative information. To overcome this, we investigate the use of a calibrated reference layer, sandwiched between the transducer and the tissue surface, to quantitatively image the unknown modulus of the examined tissue. The performance of the method was studied through simulations and experiments on agar-gelatin phantoms having Young's modulus within a range appropriate for the liver application. Furthermore, we explored the translational capability of the proposed method to work with existing commercially-available ultrasound scanners having elastography option. The Young's modulus value of the phantom estimated from quantitative elastography in simulation and experiment was compared against the corresponding ground-truth modulus value obtained from COMSOL and Universal Testing Machine (UTM) results, respectively. The results obtained for the compressive elastic modulus of the underlying phantom using quasi-static ultrasound elastography was found to be within 6% and 11% in simulation and experiments, respectively, to the corresponding ground-truth values.
Collapse
Affiliation(s)
- Sathiyamoorthy Selladurai
- Biomedical Ultrasound Laboratory, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai, India
| | - Arun K Thittai
- Biomedical Ultrasound Laboratory, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai, India.
| |
Collapse
|
5
|
Rabell-Montiel A, Anderson T, Pye SD, Moran CM. Attenuation Coefficients of the Individual Components of the International Electrotechnical Commission Agar Tissue-Mimicking Material. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:2371-2378. [PMID: 30076033 DOI: 10.1016/j.ultrasmedbio.2018.06.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2017] [Revised: 05/18/2018] [Accepted: 06/06/2018] [Indexed: 06/08/2023]
Abstract
Tissue-mimicking materials (TMMs) are widely used in quality assurance (QA) phantoms to assess the performance of ultrasound scanners. The International Electrotechnical Commission (IEC) defines the acoustic parameters of up to 10MHz. To manufacture a TMM that closely mimics the acoustical properties of small animal soft tissue at high frequencies, the acoustic properties of each of the individual component ingredients used in the IEC agar-TMM recipe need to be quantified. This study was aimed at evaluating whether the overall attenuation coefficient of the IEC agar-TMM is the linear sum of the attenuation coefficients of each of its ingredients. Eight batches of agar-based materials were manufactured with different combinations of ingredients from the IEC agar-TMM recipe. The percentage concentration of each ingredient used in the individual mixes was identical to that specified in the IEC recipe. The attenuation of each of these batches was measured over the ultrasound frequency range 12-50MHz, and the attenuation value of the agar component was subtracted from the attenuation values of the other batches. Batch attenuation values, representing the attenuation of individual components within the IEC agar-TMM, were then summated and yielded attenuation values that accurately reproduced the attenuation of the IEC agar-TMM. This information forms a valuable resource for the future development of TMMs with acoustic properties similar to those of soft tissue at high frequencies.
Collapse
Affiliation(s)
- Adela Rabell-Montiel
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom.
| | - Tom Anderson
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
| | - Steve D Pye
- Medical Physics, NHS Lothian, Royal Infirmary of Edinburgh, Edinburgh, United Kingdom
| | - Carmel M Moran
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
| |
Collapse
|
6
|
Dargar S, Akyildiz AC, De S. In Situ Mechanical Characterization of Multilayer Soft Tissue Using Ultrasound Imaging. IEEE Trans Biomed Eng 2017; 64:2595-2606. [PMID: 28026748 PMCID: PMC6218640 DOI: 10.1109/tbme.2016.2644651] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
In this paper, we report the development of a technique to characterize layer-specific nonlinear material properties of soft tissue in situ with the potential for in vivo testing. A soft tissue elastography robotic arm system comprising of a robotically manipulated 30 MHz high-resolution ultrasound probe, a custom designed compression head, and load cells has been developed to perform compression ultrasound imaging on the target tissue and measure reaction forces. A multilayer finite element model is iteratively optimized to identify the material coefficients of each layer. Validation has been performed using tissue mimicking agar-based phantoms with a low relative error of ∼7% for two-layer phantoms and ∼10% error for three layer phantoms when compared to known ground-truth values obtained using a commercial material testing system. The technique has then been used to successfully determine the in situ layer-specific mechanical properties of intact porcine stomach. The mean C10 and C20 for a second-order reduced polynomial material model were determined for the muscularis (6.41 ± 0.60, 4.29 ± 1.87 kPa), submucosal (5.21 ± 0.57, 3.68 ± 3.01 kPa), and mucosal layers (0.06 ± 0.02, 0.09 ± 0.24 kPa). Such a system can be utilized to perform in vivo mechanical characterization, which is left as future work.
Collapse
Affiliation(s)
- Saurabh Dargar
- Biomedical Engineering Department and with the Center for Modeling, Simulation and Imaging in Medicine (CeMSIM) at Rensselaer Polytechnic Institute in Troy, NY, USA.
| | - Ali C. Akyildiz
- Center for Modeling, Simulation and Imaging in Medicine (CeMSIM) at Rensselaer Polytechnic Institute in Troy, NY, USA.
| | - Suvranu De
- CeMSIM; Department of Mechanical, Aerospace and Nuclear Engineering (MANE) at Rensselaer Polytechnic Institute in Troy, NY, USA.
| |
Collapse
|
7
|
Karuppanan U, Unni SN, Angarai GR. Quantitative assessment of soft tissue deformation using digital speckle pattern interferometry: studies on phantom breast models. J Med Imaging (Bellingham) 2017; 4:016001. [PMID: 28180134 PMCID: PMC5285730 DOI: 10.1117/1.jmi.4.1.016001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2016] [Accepted: 01/06/2017] [Indexed: 12/17/2022] Open
Abstract
Assessment of mechanical properties of soft matter is a challenging task in a purely noninvasive and noncontact environment. As tissue mechanical properties play a vital role in determining tissue health status, such noninvasive methods offer great potential in framing large-scale medical screening strategies. The digital speckle pattern interferometry (DSPI)-based image capture and analysis system described here is capable of extracting the deformation information from a single acquired fringe pattern. Such a method of analysis would be required in the case of the highly dynamic nature of speckle patterns derived from soft tissues while applying mechanical compression. Soft phantoms mimicking breast tissue optical and mechanical properties were fabricated and tested in the DSPI out of plane configuration set up. Hilbert transform (HT)-based image analysis algorithm was developed to extract the phase and corresponding deformation of the sample from a single acquired fringe pattern. The experimental fringe contours were found to correlate with numerically simulated deformation patterns of the sample using Abaqus finite element analysis software. The extracted deformation from the experimental fringe pattern using the HT-based algorithm is compared with the deformation value obtained using numerical simulation under similar conditions of loading and the results are found to correlate with an average %error of 10. The proposed method is applied on breast phantoms fabricated with included subsurface anomaly mimicking cancerous tissue and the results are analyzed.
Collapse
Affiliation(s)
- Udayakumar Karuppanan
- Indian Institute of Technology Madras, Department of Applied Mechanics, Biophotonics Lab, Chennai, India
| | - Sujatha Narayanan Unni
- Indian Institute of Technology Madras, Department of Applied Mechanics, Biophotonics Lab, Chennai, India
| | - Ganesan R. Angarai
- Indian Institute of Technology Madras, Department of Physics, Applied Optics Lab, Chennai, India
| |
Collapse
|
8
|
Manickam K, Reddy MR, Seshadri S, Raghavan B. Development of a training phantom for compression breast elastography-comparison of various elastography systems and numerical simulations. J Med Imaging (Bellingham) 2015; 2:047002. [PMID: 26697511 DOI: 10.1117/1.jmi.2.4.047002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2015] [Accepted: 11/16/2015] [Indexed: 12/21/2022] Open
Abstract
The elastic properties of tissue are related to tissue composition and pathological changes. It has been observed that many pathological processes increase the elastic modulus of soft tissue compared to normal. Ultrasound compression elastography is a method of characterization of elastic properties that has been the focus of many research efforts in the last two decades. In medical radiology, compression elastography is provided as an additional tool with ultrasound B-mode in the existing scanners, and the combined features of elastography and echography act as a promising diagnostic method in breast cancer detection. However, the full capability of the ultrasound elastography technique together with B-mode has not been utilized by novice radiologists due to the nonavailability of suitable, appropriately designed tissue-mimicking phantoms. Since different commercially available ultrasound elastographic scanners follow their own unique protocols, training novice radiologists is becoming cumbersome. The main focus of this work is to develop a tissue-like agar-based phantom, which mimics breast tissue with common abnormal lesions like fibroadenoma and invasive ductal carcinoma in a clinically perceived way and compares the sonographic and elastographic appearances using different commercially available systems. In addition, the developed phantoms are simulated using the finite-element method, and ideal strain images are generated. Strain images from experiment and simulation are compared based on image contrast parameters, namely contrast transfer efficiency (CTE) and observed strain, and they are in good agreement. The strain image contrast of malignant inclusions is significantly improved compared to benign inclusions, and the trend of CTE is similar for all elastographic scanners under investigation.
Collapse
Affiliation(s)
- Kavitha Manickam
- Biomedical Engineering Group , Department of Applied Mechanics, IIT Madras, Chennai 600 036, India
| | | | | | | |
Collapse
|
9
|
Maxwell AD, Park S, Vaughan BL, Cain CA, Grotberg JB, Xu Z. Trapping of embolic particles in a vessel phantom by cavitation-enhanced acoustic streaming. Phys Med Biol 2014; 59:4927-43. [PMID: 25109407 DOI: 10.1088/0031-9155/59/17/4927] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Cavitation clouds generated by short, high-amplitude, focused ultrasound pulses were previously observed to attract, trap, and erode thrombus fragments in a vessel phantom. This phenomenon may offer a noninvasive method to capture and eliminate embolic fragments flowing through the bloodstream during a cardiovascular intervention. In this article, the mechanism of embolus trapping was explored by particle image velocimetry (PIV). PIV was used to examine the fluid streaming patterns generated by ultrasound in a vessel phantom with and without crossflow of blood-mimicking fluid. Cavitation enhanced streaming, which generated fluid vortices adjacent to the focus. The focal streaming velocity, uf, was as high as 120 cm/s, while mean crossflow velocities, uc, were imposed up to 14 cm/s. When a solid particle 3-4 mm diameter was introduced into crossflow, it was trapped near the focus. Increasing uf promoted particle trapping while increasing uc promoted particle escape. The maximum crossflow Reynolds number at which particles could be trapped, Rec, was approximately linear with focal streaming number, Ref, i.e. Rec = 0.25Ref + 67.44 (R(2) = 0.76) corresponding to dimensional velocities uc = 0.084uf + 3.122 for 20 < uf < 120 cm/s. The fluidic pressure map was estimated from PIV and indicated a negative pressure gradient towards the focus, trapping the embolus near this location.
Collapse
Affiliation(s)
- Adam D Maxwell
- Department of Biomedical Engineering, University of Michigan, 1107 Gerstacker Building, 2200 Bonisteel Boulevard, Ann Arbor, MI 48109, USA
| | | | | | | | | | | |
Collapse
|
10
|
Manickam K, Machireddy RR, Seshadri S. Characterization of biomechanical properties of agar based tissue mimicking phantoms for ultrasound stiffness imaging techniques. J Mech Behav Biomed Mater 2014; 35:132-43. [PMID: 24769915 DOI: 10.1016/j.jmbbm.2014.03.017] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2013] [Revised: 03/22/2014] [Accepted: 03/25/2014] [Indexed: 11/24/2022]
Abstract
Pathological changes of the body have been observed to change the mechanical properties of soft tissue types which can be imaged by ultrasound elastography. Though initial clinical results using ultrasound elastography in detection of tumors are promising, quantification of signal to noise ratio, resolution and strain image patterns are the best achieved under a controlled study using phantoms with similar biomechanical properties of normal and abnormal tissues. The purpose of this work is to characterize the biomechanical properties of agar based tissue mimicking phantoms by varying the agar concentration from 1.7 to 6.6% by weight and identify the optimum property to be used in classification of cancerous tissues. We performed quasi-static uniaxial compression test under a strain rate of 0.5mm/min up to 15% strain and measured Young's modulus of phantom samples which are from 50kPa to 450kPa. Phantoms show nonlinear stress-strain characteristics at finite strain which were characterized using hyperelastic parameters by fitting Neo-Hookean, Mooney Rivlin, Ogden and Veronda Westmann models. We also investigated viscoelastic parameters of the samples by conducting oscillatory shear rheometry at various precompression levels (2-5%). Loss modulus values are always less than storage modulus which represents the behavior of soft tissues. The increase in agar concentration increases the shear modulus of the samples as well as decreases the linear viscoelastic region. The results suggest that dynamic shear modul are more promising than linear and nonlinear elastic modul in differentiation of various classes of abnormal tissues.
Collapse
Affiliation(s)
- Kavitha Manickam
- Biomedical Engineering Group, Department of Applied Mechanics, IIT Madras, Chennai 600 036, India.
| | | | | |
Collapse
|