Bosio G, Destrempes F, Yazdani L, Roy Cardinal MH, Cloutier G. Resonance, Velocity, Dispersion, and Attenuation of Ultrasound-Induced Shear Wave Propagation in Blood Clot In Vitro Models. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2024; 43:535-551. [PMID: 38108551 DOI: 10.1002/jum.16387] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 11/24/2023] [Accepted: 11/25/2023] [Indexed: 12/19/2023]
Abstract
OBJECTIVE Improve the characterization of mechanical properties of blood clots. Parameters derived from shear wave (SW) velocity and SW amplitude spectra were determined for gel phantoms and in vitro blood clots. METHODS Homogeneous phantoms and phantoms with gel or blood clot inclusions of different diameters and mechanical properties were analyzed. SW amplitude spectra were used to observe resonant peaks. Parameters derived from those resonant peaks were related to mimicked blood clot properties. Three regions of interest were tested to analyze where resonances occurred the most. For blood experiments, 20 samples from different pigs were analyzed over time during a 110-minute coagulation period using the Young modulus, SW frequency dispersion, and SW attenuation. RESULTS The mechanical resonance was manifested by an increase in the number of SW spectral peaks as the inclusion diameter was reduced (P < .001). In blood clot inclusions, the Young modulus increased over time during coagulation (P < .001). Descriptive spectral parameters (frequency peak, bandwidth, and distance between resonant peaks) were linearly correlated with clot elasticity values (P < .001) with R2 = .77 for the frequency peak, .60 for the bandwidth, and .48 for the distance between peaks. The SW dispersion and SW attenuation reflecting the viscous behavior of blood clots decreased over time (P < .001), mainly in the early stage of coagulation (first minutes). CONCLUSION The confined soft inclusion configuration favored SW mechanical resonances potentially challenging the computation of spectral-based parameters, such as the SW attenuation. The impact of resonances can be reduced by properly selecting the region of interest for data analysis.
Collapse
Affiliation(s)
- Guillaume Bosio
- Institute of Biomedical Engineering, University of Montreal, Montreal, Quebec, Canada
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - François Destrempes
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - Ladan Yazdani
- Institute of Biomedical Engineering, University of Montreal, Montreal, Quebec, Canada
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - Marie-Hélène Roy Cardinal
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - Guy Cloutier
- Institute of Biomedical Engineering, University of Montreal, Montreal, Quebec, Canada
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
- Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montreal, Montreal, Quebec, Canada
| |
Collapse
|
2
|
Mobadersany N, Liang P, Kemper P, Konofagou EE. Polyvinyl Alcohol Phantoms With Heterogeneous Plaques: Estimation of Pulse Wave Velocity at the Stenotic Region Using Pulse Wave Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:91-98. [PMID: 37838523 PMCID: PMC11102764 DOI: 10.1016/j.ultrasmedbio.2023.09.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 09/01/2023] [Accepted: 09/08/2023] [Indexed: 10/16/2023]
Abstract
OBJECTIVE Plaque characterization is essential for stroke prevention. In the study reported herein, we describe a heterogeneous phantom manufacturing technique with varying plaque compositions of different stiffness using polyvinyl alcohol (PVA) to emulate stenotic arteries and evaluated the use of pulse wave imaging (PWI) to assess plaque stiffness by comparing derived pulse wave velocities, with the goal of assessing plaque vulnerability and identifying high-risk patients for stroke. METHODS Five stenotic phantoms (50% stenosis) were fabricated by pouring PVA solutions into 3-D-printed molds. Two of the phantoms had heterogeneous plaque compositions of soft (E0 = 13 kPa) and intermediate (E0 = 40 kPa) materials and of stiff (E0 = 54 kPa) and intermediate materials. Ultrasound sequences were acquired as the arterial phantoms were connected to a pulsating pump, and PWI was performed on the ultrasound acquisition using normalized cross-correlation to track the pulse-induced phantom wall distension propagations. Pulse wave velocities were estimated by fitting a linear regression line between the arrival time of the peak acceleration of the wall distension waveform and the corresponding location. RESULTS Arterial phantoms with heterogeneous plaque stiffness were successfully fabricated. Pulse wave velocities of 2.06, 2.21, 2.49, 2.67 and 3.31 m/s were found in the phantom experiments using PWI for homogeneous soft plaque, the heterogeneous soft and intermediate plaque, homogeneous intermediate plaque, the heterogeneous stiff and intermediate plaque and homogeneous stiff plaque, respectively. CONCLUSION A novel arterial phantom building technique was reported with varying heterogenous plaque compositions of different stiffness. The feasibility of using PWI to evaluate plaque stiffness in stenotic arteries was determined and found that PWI can distinguish between plaques of distinct stiffness and composition.
Collapse
Affiliation(s)
- Nima Mobadersany
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Pengcheng Liang
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Paul Kemper
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Elisa E Konofagou
- Department of Biomedical Engineering, Columbia University, New York, NY, USA; Department of Radiology, Columbia University, New York, New York, NY, USA.
| |
Collapse
|
3
|
Mukaddim RA, Liu Y, Graham M, Eickhoff JC, Weichmann AM, Tattersall MC, Korcarz CE, Stein JH, Varghese T, Eliceiri KW, Mitchell C. In Vivo Adaptive Bayesian Regularized Lagrangian Carotid Strain Imaging for Murine Carotid Arteries and Its Associations With Histological Findings. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:2103-2112. [PMID: 37400303 PMCID: PMC10527160 DOI: 10.1016/j.ultrasmedbio.2023.05.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 05/23/2023] [Accepted: 05/28/2023] [Indexed: 07/05/2023]
Abstract
OBJECTIVES Non-invasive methods for monitoring arterial health and identifying early injury to optimize treatment for patients are desirable. The objective of this study was to demonstrate the use of an adaptive Bayesian regularized Lagrangian carotid strain imaging (ABR-LCSI) algorithm for monitoring of atherogenesis in a murine model and examine associations between the ultrasound strain measures and histology. METHODS Ultrasound radiofrequency (RF) data were acquired from both the right and left common carotid artery (CCA) of 10 (5 male and 5 female) ApoE tm1Unc/J mice at 6, 16 and 24 wk. Lagrangian accumulated axial, lateral and shear strain images and three strain indices-maximum accumulated strain index (MASI), peak mean strain of full region of interest (ROI) index (PMSRI) and strain at peak axial displacement index (SPADI)-were estimated using the ABR-LCSI algorithm. Mice were euthanized (n = 2 at 6 and 16 wk, n = 6 at 24 wk) for histology examination. RESULTS Sex-specific differences in strain indices of mice at 6, 16 and 24 wk were observed. For male mice, axial PMSRI and SPADI changed significantly from 6 to 24 wk (mean axial PMSRI at 6 wk = 14.10 ± 5.33% and that at 24 wk = -3.03 ± 5.61%, p < 0.001). For female mice, lateral MASI increased significantly from 6 to 24 wk (mean lateral MASI at 6 wk = 10.26 ± 3.13% and that at 24 wk = 16.42 ± 7.15%, p = 0.048). Both cohorts exhibited strong associations with ex vivo histological findings (male mice: correlation between number of elastin fibers and axial PMSRI: rs = 0.83, p = 0.01; female mice: correlation between shear MASI and plaque score: rs = 0.77, p = 0.009). CONCLUSION The results indicate that ABR-LCSI can be used to measure arterial wall strain in a murine model and that changes in strain are associated with changes in arterial wall structure and plaque formation.
Collapse
Affiliation(s)
- Rashid Al Mukaddim
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA
| | - Yuming Liu
- Laboratory for Optical and Computational Instrumentation, Center for Quantitative Cell Imaging, University of Wisconsin-Madison, Madison, WI, USA
| | - Melissa Graham
- Research Animal Resources and Compliance, Comparative Pathology Laboratory, University of Wisconsin-Madison, Madison, WI, USA
| | - Jens C Eickhoff
- Department of Biostatistics and Medical Informatics, University of Wisconsin-Madison, Madison, WI, USA
| | - Ashley M Weichmann
- Small Animal Imaging and Radiotherapy Facility, Carbone Cancer Center, University of Wisconsin-Madison, Madison, WI, USA
| | | | - Claudia E Korcarz
- Department of Medicine, University of Wisconsin-Madison, Madison, WI, USA
| | - James H Stein
- Department of Medicine, University of Wisconsin-Madison, Madison, WI, USA
| | - Tomy Varghese
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA
| | - Kevin W Eliceiri
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA; Laboratory for Optical and Computational Instrumentation, Center for Quantitative Cell Imaging, University of Wisconsin-Madison, Madison, WI, USA; Small Animal Imaging and Radiotherapy Facility, Carbone Cancer Center, University of Wisconsin-Madison, Madison, WI, USA; Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA; Morgridge Institute for Research, Madison, WI, USA
| | - Carol Mitchell
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA; Department of Medicine, University of Wisconsin-Madison, Madison, WI, USA.
| |
Collapse
|
4
|
Wang Y, Wei X, Pan Z, Huang L, He Q, Luo J. Influence of key parameters on motion artifacts in lateral strain estimation with spatial angular compounding. ULTRASONICS 2022; 125:106799. [PMID: 35797866 DOI: 10.1016/j.ultras.2022.106799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 06/23/2022] [Accepted: 06/26/2022] [Indexed: 06/15/2023]
Abstract
Strain imaging can reveal the changes in tissue mechanical properties related to pathological alterations by estimating tissue strains in the lateral and axial directions of ultrasound imaging. The estimation performance in the lateral direction is usually worse than that in the axial direction. Spatial angular compounding (SAC) has been demonstrated to improve the quality of lateral estimation by deriving the lateral displacements using axial displacements obtained from multi-angle transmissions. However, motion and deformation of tissues during multiple transmissions may cause motion artifacts, and thus deteriorate the quality of strain estimation. These artifacts can be reduced by choosing appropriate imaging parameters. However, few studies have been conducted to evaluate the influences of key parameters in strain estimation, such as the pulse repetition frequency (PRF), the number of steering angles (NSA), and the maximum steering angles (MSA), in terms of performance optimization. Therefore, this study aims to investigate the effects of these parameters through simulations and phantom experiments. The performance of strain estimation is evaluated by measuring the root-mean-square error (RMSE) and the standard deviation (SD) in the simulations and phantom experiments, respectively. The contrast-to-noise ratio (CNR) of strain images is calculated in both the simulations and phantom experiments. The results show that motion artifacts in strain estimation can be reduced by increasing the PRF to 1 kHz. When the PRF reaches 1 kHz, further increase of the PRF shows little obvious improvement in strain estimation. An increase in the NSA can cause larger motion artifacts and deteriorate the quality of strain images, and the improvement of strain estimation is limited when the NSA is increased from 3 to 7. An NSA of 3 is thus recommended to balance the influences of motion artifacts and the improvement for strain estimation. The MSA has little influence on the motion artifacts, while increased MSA can achieve improved lateral estimation performance at the cost of a smaller imaging region. In light of the lateral strain estimation performance and imaging region, an MSA of 15° is recommended. The influences of these key parameters obtained from this study may provide insights for parameter optimization in strain estimation with SAC to minimize the effects of motion artifacts.
Collapse
Affiliation(s)
- Yuanyuan Wang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Xingyue Wei
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Zonghui Pan
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Lijie Huang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Qiong He
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China; Tsinghua-Peking Joint Center for Life Sciences, Tsinghua University, Beijing 100084, China.
| | - Jianwen Luo
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.
| |
Collapse
|
5
|
Roy Cardinal MH, Durand M, Chartrand-Lefebvre C, Soulez G, Tremblay C, Cloutier G. Associative Prediction of Carotid Artery Plaques Based on Ultrasound Strain Imaging and Cardiovascular Risk Factors in People Living With HIV and Age-Matched Control Subjects of the CHACS Cohort. J Acquir Immune Defic Syndr 2022; 91:91-100. [PMID: 35510848 DOI: 10.1097/qai.0000000000003016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Accepted: 04/26/2022] [Indexed: 11/27/2022]
Abstract
BACKGROUND There is a need for a specific atherosclerotic risk assessment for people living with HIV (PLWH). SETTING A machine learning classification model was applied to PLWH and control subjects with low-to-intermediate cardiovascular risks to identify associative predictors of diagnosed carotid artery plaques. Associations with plaques were made using strain elastography in normal sections of the common carotid artery and traditional cardiovascular risk factors. METHODS One hundred two PLWH and 84 control subjects were recruited from the prospective Canadian HIV and Aging Cohort Study (57 ± 8 years; 159 men). Plaque presence was based on clinical ultrasound scans of left and right common carotid arteries and internal carotid arteries. A classification task for identifying subjects with plaque was defined using random forest (RF) and logistic regression models. Areas under the receiver operating characteristic curves (AUC-ROCs) were applied to select 5 among 50 combinations of 4 or less features yielding the highest AUC-ROCs. RESULTS To retrospectively classify individuals with and without plaques, the 5 most discriminant combinations of features had AUC-ROCs between 0.76 and 0.79. AUC-ROCs from RF were statistically significantly higher than those obtained with logistic regressions ( P = 0.0001). The most discriminant features of RF classifications in PLWH were age, smoking status, maximum axial strain and pulse pressure (equal weights), and sex and antiretroviral therapy exposure (equal weights). When considering the whole population, the HIV status was identified as a cofactor associated with carotid artery plaques. CONCLUSIONS Strain elastography adds to traditional cardiovascular risk factors for identifying individuals with carotid artery plaques.
Collapse
Affiliation(s)
- Marie-Hélène Roy Cardinal
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montréal, Québec, Canada
| | - Madeleine Durand
- Department of Internal Medicine, University of Montreal Hospital, Montréal, Québec, Canada
- Department of Medicine, University of Montreal, Montréal, Québec, Canada
| | - Carl Chartrand-Lefebvre
- Department of Radiology, University of Montreal Hospital, Montréal, Québec, Canada
- Department of Radiology, Radio-oncology, and Nuclear Medicine, University of Montreal, Montréal, Québec, Canada
| | - Gilles Soulez
- Department of Radiology, University of Montreal Hospital, Montréal, Québec, Canada
- Department of Radiology, Radio-oncology, and Nuclear Medicine, University of Montreal, Montréal, Québec, Canada
- Institute of Biomedical Engineering, University of Montreal, Montréal, Québec, Canada
| | - Cécile Tremblay
- Department of Microbiology and Infectious Diseases, University of Montreal Hospital, Montréal, Québec, Canada; and
- Department of Microbiology, Infectious Diseases, and Immunology, University of Montreal, Montréal, Québec, Canada
| | - Guy Cloutier
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montréal, Québec, Canada
- Department of Radiology, Radio-oncology, and Nuclear Medicine, University of Montreal, Montréal, Québec, Canada
- Institute of Biomedical Engineering, University of Montreal, Montréal, Québec, Canada
| |
Collapse
|
6
|
Wang Y, Xie X, He Q, Liao H, Zhang H, Luo J. Hadamard-Encoded Synthetic Transmit Aperture Imaging for Improved Lateral Motion Estimation in Ultrasound Elastography. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1204-1218. [PMID: 35100113 DOI: 10.1109/tuffc.2022.3148332] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Lateral motion estimation has been a challenge in ultrasound elastography mainly due to the low resolution, low sampling frequency, and lack of phase information in the lateral direction. Synthetic transmit aperture (STA) can achieve high resolution due to two-way focusing and can beamform high-density image lines for improved lateral motion estimation with the disadvantages of low signal-to-noise ratio (SNR) and limited penetration depth. In this study, Hadamard-encoded STA (Hadamard-STA) is proposed for the improvement of lateral motion estimation in elastography, and it is compared with STA and conventional focused wave (CFW) imaging. Simulations, phantom, and in vivo experiments were conducted to make the comparison. The normalized root mean square error (NRMSE) and the contrast-to-noise ratio (CNR) were calculated as the evaluation criteria in the simulations. The results show that, at a noise level of -10 dB and an applied strain of -1% (compression), Hadamard-STA decreases the NRMSEs of lateral displacements by 46.92% and 35.35%, decreases the NRMSEs of lateral strains by 52.34% and 39.75%, and increases the CNRs by 9.70 and 9.75 dB compared with STA and CFW, respectively. In the phantom experiments performed on a heterogeneous tissue-mimicking phantom, the sum of squared differences (SSD) between the reference and the motion-compensated RF data, and the CNR were calculated as the evaluation criteria. At an applied strain of -1.80%, Hadamard-STA is found to decrease the SSDs by 20.91% and 30.99% and increase the CNRs by 14.15 and 24.66 dB compared with STA and CFW, respectively. In the experiments performed on a breast phantom, Hadamard-STA achieves better visualization of the breast inclusion with a clearer boundary between the inclusion and the background than STA and CFW. The in vivo experiments were performed on a patient with a breast tumor, and the tumor could also be better visualized with a more homogeneous background in the strain image obtained by Hadamard-STA than by STA and CFW. These results demonstrate that Hadamard-STA achieves a substantial improvement in lateral motion estimation and maybe a competitive method for quasi-static elastography.
Collapse
|
7
|
Benech N, Camargo A, Negreira C. Simplified Green's function for surface waves in quasi-incompressible elastic plates with application to elastography. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2022; 34:214004. [PMID: 35234669 DOI: 10.1088/1361-648x/ac5993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Accepted: 03/01/2022] [Indexed: 06/14/2023]
Abstract
Surface wave elastography is a growing method to estimate the elasticity in soft solids. It is particularly useful in the case of agrifoods like meat, cheese, or fruits because it does not require major infrastructure or large equipment and could be developed in portable devices. However, estimating the shear elastic properties from surface wave measurements is not straightforward. The shear wavelength in those materials is cm sized for the excitation frequencies usually employed in elastography (∼102 Hz), and the size of samples is comparable to it. Thus, the surface wave speed is frequency dependent with no direct relation to the shear wave speed. In this work we propose a simplified Green's function for soft solid elastic plates which allows to retrieve the shear elasticity from near field measurements. The model is compared with experimental results obtained in agar-gelatin phantoms and food samples (cheese and bovine liver). The results show a good overall agreement although improvements can be achieved by incorporating diffraction and viscosity to the model.
Collapse
Affiliation(s)
- Nicolás Benech
- Laboratorio de Acústica Ultrasonora, Facultad de Ciencias, Universidad de la República, Igua 4225, 11400, Montevideo, Uruguay
| | - Andrés Camargo
- Laboratorio de Acústica Ultrasonora, Facultad de Ciencias, Universidad de la República, Igua 4225, 11400, Montevideo, Uruguay
| | - Carlos Negreira
- Laboratorio de Acústica Ultrasonora, Facultad de Ciencias, Universidad de la República, Igua 4225, 11400, Montevideo, Uruguay
| |
Collapse
|
8
|
van Hees R, Muller JW, van de Vosse F, Rutten M, van Sambeek M, Wu M, Lopata R. SVD-based filtering to detect intraplaque hemorrhage using single wavelength photoacoustic imaging. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210198RR. [PMID: 34743446 PMCID: PMC8571807 DOI: 10.1117/1.jbo.26.11.116003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Accepted: 10/15/2021] [Indexed: 06/13/2023]
Abstract
SIGNIFICANCE Intraplaque hemorrhage (IPH) is an important indicator of plaque vulnerability. Early detection could aid the prevention of stroke. AIM We aim to detect IPH with single wavelength PA imaging in vivo and to improve image quality. APPROACH We developed a singular value decomposition (SVD)-based filter to detect the nonstationary and stationary components in ultrasound data. A PA mask was created to detect stationary (IPH) sources. The method was tested ex vivo using phantoms and in vivo in patients. RESULTS The flow and IPH channels were successfully separated in the phantom data. We can also detect the PA signals from IPH and reject signals from the carotid lumen in vivo. Generalized contrast-to-noise ratio improved in both ex vivo and in vivo in US imaging. CONCLUSIONS SVD-based filtering can successfully detect IPH using a single laser wavelength, opening up opportunities for more economical and cost-effective laser sources.
Collapse
Affiliation(s)
- Roy van Hees
- Eindhoven University of Technology, Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven, The Netherlands
| | - Jan-Willem Muller
- Eindhoven University of Technology, Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven, The Netherlands
| | - Frans van de Vosse
- Eindhoven University of Technology, Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven, The Netherlands
| | - Marcel Rutten
- Eindhoven University of Technology, Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven, The Netherlands
| | - Marc van Sambeek
- Eindhoven University of Technology, Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven, The Netherlands
- Catharina Hospital, Eindhoven, The Netherlands
| | - Min Wu
- Eindhoven University of Technology, Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven, The Netherlands
| | - Richard Lopata
- Eindhoven University of Technology, Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven, The Netherlands
| |
Collapse
|
9
|
Karageorgos GM, Apostolakis IZ, Nauleau P, Gatti V, Weber R, Kemper P, Konofagou EE. Pulse Wave Imaging Coupled With Vector Flow Mapping: A Phantom, Simulation, and In Vivo Study. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2516-2531. [PMID: 33950838 PMCID: PMC8477914 DOI: 10.1109/tuffc.2021.3074113] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Pulse wave imaging (PWI) is an ultrasound imaging modality that estimates the wall stiffness of an imaged arterial segment by tracking the pulse wave propagation. The aim of the present study is to integrate PWI with vector flow imaging, enabling simultaneous and co-localized mapping of vessel wall mechanical properties and 2-D flow patterns. Two vector flow imaging techniques were implemented using the PWI acquisition sequence: 1) multiangle vector Doppler and 2) a cross-correlation-based vector flow imaging (CC VFI) method. The two vector flow imaging techniques were evaluated in vitro using a vessel phantom with an embedded plaque, along with spatially registered fluid structure interaction (FSI) simulations with the same geometry and inlet flow as the phantom setup. The flow magnitude and vector direction obtained through simulations and phantom experiments were compared in a prestenotic and stenotic segment of the phantom and at five different time frames. In most comparisons, CC VFI provided significantly lower bias or precision than the vector Doppler method ( ) indicating better performance. In addition, the proposed technique was applied to the carotid arteries of nonatherosclerotic subjects of different ages to investigate the relationship between PWI-derived compliance of the arterial wall and flow velocity in vivo. Spearman's rank-order test revealed positive correlation between compliance and peak flow velocity magnitude ( rs = 0.90 and ), while significantly lower compliance ( ) and lower peak flow velocity magnitude ( ) were determined in older (54-73 y.o.) compared with young (24-32 y.o.) subjects. Finally, initial feasibility was shown in an atherosclerotic common carotid artery in vivo. The proposed imaging modality successfully provided information on blood flow patterns and arterial wall stiffness and is expected to provide additional insight in studying carotid artery biomechanics, as well as aid in carotid artery disease diagnosis and monitoring.
Collapse
|
10
|
Increased carotid artery wall stiffness and plaque prevalence in HIV infected patients measured with ultrasound elastography. Eur Radiol 2020; 30:3178-3187. [DOI: 10.1007/s00330-020-06660-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2019] [Revised: 12/17/2019] [Accepted: 01/17/2020] [Indexed: 12/27/2022]
|
11
|
Apostolakis LZ, Karageorgos GM, Nauleau P, Nandlall SD, Konofagou EE. Adaptive Pulse Wave Imaging: Automated Spatial Vessel Wall Inhomogeneity Detection in Phantoms and in-Vivo. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:259-269. [PMID: 31265387 PMCID: PMC6938555 DOI: 10.1109/tmi.2019.2926141] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Imaging arterial mechanical properties may improve vascular disease diagnosis. Pulse wave velocity (PWV) is a marker of arterial stiffness linked to cardio-vascular mortality. Pulse wave imaging (PWI) is a technique for imaging the pulse wave propagation at high spatial and temporal resolution. In this paper, we introduce adaptive PWI, a technique for the automated partition of heterogeneous arteries into individual segments characterized by most homogeneous pulse wave propagation, allowing for more robust PWV estimation. This technique was validated in a silicone phantom with a soft-stiff interface. The mean detection error of the interface was 4.67 ± 0.73 mm and 3.64 ± 0.14 mm in the stiff-to-soft and soft-to-stiff pulse wave transmission direction, respectively. This technique was tested in monitoring the progression of atherosclerosis in mouse aortas in vivo ( n = 11 ). The PWV was found to already increase at the early stage of 10 weeks of high-fat diet (3.17 ± 0.67 m/sec compared to baseline 2.55 ± 0.47 m/sec, ) and further increase after 20 weeks of high-fat diet (3.76±1.20 m/sec). The number of detected segments of the imaged aortas monotonically increased with the duration of high-fat diet indicating an increase in arterial wall property inhomogeneity. The performance of adaptive PWI was also tested in aneurysmal mouse aortas in vivo. Aneurysmal boundaries were detected with a mean error of 0.68±0.44 mm. Finally, initial feasibility was shown in the carotid arteries of healthy and atherosclerotic human subjects in vivo ( n = 3 each). Consequently, adaptive PWI was successful in detecting stiffness inhomogeneity at its early onset and monitoring atherosclerosis progression in vivo.
Collapse
Affiliation(s)
| | | | - Pierre Nauleau
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Sacha D. Nandlall
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Elisa E. Konofagou
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
- Department of Radiology, Columbia University, New York, NY, USA
| |
Collapse
|
12
|
Varghese T, Meshram NH, Mitchell CC, Wilbrand SM, Hermann BP, Dempsey RJ. Lagrangian carotid strain imaging indices normalized to blood pressure for vulnerable plaque. JOURNAL OF CLINICAL ULTRASOUND : JCU 2019; 47:477-485. [PMID: 31168787 PMCID: PMC6760247 DOI: 10.1002/jcu.22739] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Revised: 05/10/2019] [Accepted: 05/22/2019] [Indexed: 05/14/2023]
Abstract
OBJECTIVE Ultrasound Lagrangian carotid strain imaging (LCSI) utilizes physiological deformation caused by arterial pressure variations to generate strain tensor maps of the vessel walls and plaques. LCSI has been criticized for the lack of normalization of magnitude-based strain indices to physiological stimuli, namely blood pressure. We evaluated the impact of normalization of magnitude-based strain indices to blood pressure measured immediately after the acquisition of radiofrequency (RF) data loops for LCSI. MATERIALS AND METHODS A complete clinical ultrasound examination along with RF data loops for LCSI was performed on 50 patients (30 males and 20 females) who presented with >60% carotid stenosis and were scheduled for carotid endarterectomy. Cognition was assessed using the 60-minute neuropsychological test protocol. RESULTS For axial strains correlation of maximum accumulated strain indices (MASI), cognition scores were -0.46 for non-normalized and -0.45, -0.49, -0.37, and -0.48 for systolic, diastolic, pulse pressure, and mean arterial pressure normalized data, respectively. The corresponding area under the curve (AUC) values for classifiers designed using maximum likelihood estimation of a binormal distribution with a median-split of the executive function cognition scores were 0.73, 0.70, 0.71, 0.70, and 0.71, respectively. CONCLUSIONS No significant differences in the AUC estimates were obtained between normalized and non-normalized magnitude-based strain indices.
Collapse
Affiliation(s)
- Tomy Varghese
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin
| | - Nirvedh H Meshram
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin
| | - Carol C Mitchell
- Department of Medicine, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | - Stephanie M Wilbrand
- Department of Neurological Surgery, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | - Bruce P Hermann
- Department of Neurology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | - Robert J Dempsey
- Department of Neurological Surgery, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| |
Collapse
|
13
|
Fekkes S, Hansen HHG, Menssen J, Saris AECM, de Korte CL. 3-D Strain Imaging of the Carotid Bifurcation: Methods and in-Human Feasibility. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1675-1690. [PMID: 31005369 DOI: 10.1016/j.ultrasmedbio.2019.02.023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2018] [Revised: 02/16/2019] [Accepted: 02/26/2019] [Indexed: 06/09/2023]
Abstract
Atherosclerotic plaque development in the carotid artery bifurcation elevates the risk for stroke, which is often initiated by plaque rupture. The risk-to-rupture of a plaque is related to its composition. Two-dimensional non-invasive carotid elastography studies have found a correlation between wall strain and plaque composition. This study introduces a technique to perform non-invasive volumetric elastography in vivo. Three-dimensional ultrasound data of carotid artery bifurcations were acquired in four asymptomatic individuals using an electrocardiogram-triggered multislice acquisition device that scanned over a length of 35 mm (350 slices) using a linear transducer (L11-3, fc = 9 MHz). For each slice, three-angle ultrasound plane wave data were acquired and beamformed. A correction for breathing-induced motion was applied to spatially align the slices, enabling 3-D cross-correlation-based compound displacement, distensibility and strain estimation. Distensibility values matched with previously published values, while the corresponding volumetric principal strain maps revealed locally elevated compressive and tensile strains. This study presents for the first time 3-D elastography of carotid arteries in vivo.
Collapse
Affiliation(s)
- Stein Fekkes
- Medical Ultrasound Imaging Center, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands.
| | - Hendrik H G Hansen
- Medical Ultrasound Imaging Center, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Jan Menssen
- Medical Ultrasound Imaging Center, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Anne E C M Saris
- Medical Ultrasound Imaging Center, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Chris L de Korte
- Medical Ultrasound Imaging Center, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| |
Collapse
|
14
|
Ahmadzadeh SH, Chen X, Hagemann H, Tang MX, Bull AM. Developing and using fast shear wave elastography to quantify physiologically-relevant tendon forces. Med Eng Phys 2019; 69:116-122. [DOI: 10.1016/j.medengphy.2019.04.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Revised: 04/07/2019] [Accepted: 04/14/2019] [Indexed: 01/08/2023]
|
15
|
Zhang H, Song M, Ruan L, Zhang F, Zhang A, Siedlecki AM, Wan M. Von Mises Strain as a Risk Marker for Vulnerability of Carotid Plaque: Preliminary Clinical Evaluation of Cerebral Infarction. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1221-1233. [PMID: 30824309 DOI: 10.1016/j.ultrasmedbio.2019.01.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2018] [Revised: 11/21/2018] [Accepted: 01/07/2019] [Indexed: 06/09/2023]
Abstract
Non-invasive assessment of carotid artery plaque vulnerability is a key issue for cerebrovascular disease. This study investigates Von Mises strain imaging in patients by relating Von Mises strain to cerebral infarction presentation. Ultrasonography was performed in patients evaluated for carotid artery stenosis. Strains were estimated by a flow-driven diffusion method and least-squares regression applying Kalman filtering. Von Mises strains ɛVMsys and ɛVMdia were calculated by averaging four or five cardiac cycles in systole and diastole, respectively. Von Mises strain (peak, coefficient of variance, skewness and kurtosis) in patients with cerebral infarction was compared with that in the control group. Higher Von Mises peak strain localized to echolucent areas on B-mode imaging. Higher peak strain was found in patients with cerebral infarction compared with the control group (p = 0.02 for ɛVMdia and p = 0.001 for ɛVMsys). The area under the receiver operating characteristic curve for peak ɛVMsys was 0.761 (p = 0.001) with high sensitivity and specificity. Peak strain also correlated with homocysteine (r = 0.345, p = 0.007, for ɛVMdia; r = 0.287, p = 0.036, for ɛVMsys) and hypersensitive C-reactive protein (r = 0.399, p = 0.043, for ɛVMdia; r = 0.195, p = 0.034, for ɛVMsys) levels. The coefficient of variance, skewness and kurtosis of ɛVMdia or ɛVMsys were also associated with homocysteine levels. In conclusion, this study indicates that peak Von Mises strain is a potential clinical risk marker for carotid plaque vulnerability and cerebral infarction.
Collapse
Affiliation(s)
- Hongmei Zhang
- Key Laboratory of Biomedical Information Engineering, Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, China.
| | - Manman Song
- Key Laboratory of Biomedical Information Engineering, Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, China
| | - Litao Ruan
- Department of Ultrasound, First Affiliated Hospital of Xi'an Jiaotong University, China
| | - Furong Zhang
- Department of Ultrasound, First Affiliated Hospital of Xi'an Jiaotong University, China
| | - Aifeng Zhang
- Divisions of Genetics and Cardiovascular Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Andrew M Siedlecki
- Division of Nephrology, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
| | - Mingxi Wan
- Key Laboratory of Biomedical Information Engineering, Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, China.
| |
Collapse
|
16
|
Marlevi D, Maksuti E, Urban MW, Winter R, Larsson M. Plaque characterization using shear wave elastography—evaluation of differentiability and accuracy using a combined ex vivo and in vitro setup. ACTA ACUST UNITED AC 2018; 63:235008. [DOI: 10.1088/1361-6560/aaec2b] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
17
|
Fast Von Mises strain imaging on ultrasound carotid vessel wall by flow driven diffusion method. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2018; 41:669-686. [DOI: 10.1007/s13246-018-0662-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2017] [Accepted: 06/24/2018] [Indexed: 11/28/2022]
|
18
|
Fekkes S, Saris AECM, Nillesen MM, Menssen J, Hansen HHG, de Korte CL. Simultaneous Vascular Strain and Blood Vector Velocity Imaging Using High-Frequency Versus Conventional-Frequency Plane Wave Ultrasound: A Phantom Study. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:1166-1181. [PMID: 29993371 DOI: 10.1109/tuffc.2018.2834724] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Plaque strain and blood vector velocity imaging of stenosed arteries are expected to aid in diagnosis and prevention of cerebrovascular disease. Ultrafast plane wave imaging enables simultaneous strain and velocity estimation. Multiple ultrasound vendors are introducing high-frequency ultrasound probes and systems. This paper investigates whether the use of high-frequency ultrafast ultrasound is beneficial for assessing blood velocities and strain in arteries. The performance of strain and blood flow velocity estimation was compared between a high-frequency transducer (MS250, fc = 21 MHz) and a clinically utilized transducer (L12-5, fc = 9 MHz). Quantitative analysis based on straight tube phantom experiments revealed that the MS250 outperformed the L12-5 in the superficial region: low velocities near the wall were more accurately estimated and wall strains were better resolved. At greater than 2-cm echo depth, the L12-5 performed better due to the high attenuation of the MS250 probe. Qualitative comparison using a perfused patient-specific carotid bifurcation phantom confirmed these findings. Thus, in conclusion, for strain and blood velocity estimation for depths up to ~2 cm, a high-frequency probe is recommended.
Collapse
|
19
|
Nayak R, Schifitto G, Doyley MM. Visualizing Angle-Independent Principal Strains in the Longitudinal View of the Carotid Artery: Phantom and In Vivo Evaluation. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1379-1391. [PMID: 29685590 PMCID: PMC5960628 DOI: 10.1016/j.ultrasmedbio.2018.03.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2017] [Revised: 02/08/2018] [Accepted: 03/16/2018] [Indexed: 05/03/2023]
Abstract
Non-invasive vascular elastography can evaluate the stiffness of the carotid artery by visualizing the vascular strain distribution. Axial strain estimates of the longitudinal cross section of the carotid artery are sensitive to the angle between the artery and the transducer. Anatomical variations in branching and arching of the carotid artery can affect the assessment of arterial stiffness. In this study, we hypothesized that principal strain elastograms computed using compounded plane wave imaging can reliably visualize the strain distribution in the carotid artery, independent of the transducer angle. We corroborated this hypothesis by conducting phantom and in vivo studies using a commercial ultrasound scanner (Sonix RP, Ultrasonix Medical Corp., Richmond, BC, Canada). The phantom studies were conducted using a homogeneous cryogel vessel phantom. The goal of the phantom study was to assess the feasibility of visualizing the radial deformation in the longitudinal plane of the vessel phantom, independent of the transducer angle (±30°, ±20°, ±10° and 0°). The in vivo studies were conducted on 20 healthy human volunteers in the age group 50-60 y. All echo imaging was performed at a transmit frequency of 5 MHz and sampling frequency of 40 MHz. The elastograms obtained from the phantom study revealed that for straight vessels, which had their lumen parallel to the transducer, principal strains were similar to axial strains. At non-parallel configurations (angles ±30°, ±20° and ±10°), the magnitudes of the mean principal strains were within 2.5% of the parallel configuration (0° angle) estimates and, thus, were observed to be relatively unaffected by change in angle. However, in comparison, the magnitude of the axial strain decreased with increase in angle because of coordinate dependency. Further, the pilot in vivo study indicated that the principal and axial strain elastograms were similar for subjects with relatively straight arteries. However, for arteries with arched geometry, axial strains were significantly lower (p <0.01) than the corresponding principal vascular strains, which was consistent with the results obtained from the phantom study. In conclusion, the results of the phantom and in vivo studies revealed that principal strain elastograms computed using CPW imaging could reliably visualize angle-independent vascular strains in the longitudinal plane of the carotid artery.
Collapse
Affiliation(s)
- Rohit Nayak
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, New York, USA.
| | - Giovanni Schifitto
- Department of Neurology, School of Medicine and Dentistry, University of Rochester Medical Center, Rochester, New York, USA
| | - Marvin M Doyley
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, New York, USA; Department of Biomedical Engineering, University of Rochester, Rochester, New York, USA
| |
Collapse
|
20
|
Multi-Plane Ultrafast Compound 3D Strain Imaging: Experimental Validation in a Carotid Bifurcation Phantom. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8040637] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
21
|
Poree J, Chayer B, Soulez G, Ohayon J, Cloutier G. Noninvasive Vascular Modulography Method for Imaging the Local Elasticity of Atherosclerotic Plaques: Simulation and In Vitro Vessel Phantom Study. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:1805-1817. [PMID: 28961110 DOI: 10.1109/tuffc.2017.2757763] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Mechanical and morphological characterization of atherosclerotic lesions in carotid arteries remains an essential step for the evaluation of rupture prone plaques and the prevention of strokes. In this paper, we propose a noninvasive vascular imaging modulography (NIV-iMod) method, which is capable of reconstructing a heterogeneous Young's modulus distribution of a carotid plaque from the Von Mises strain elastogram. Elastograms were computed with noninvasive ultrasound images using the Lagrangian speckle model estimator and a dynamic segmentation-optimization procedure to highlight mechanical heterogeneities. This methodology, based on continuum mechanics, was validated in silico with finite-element model strain fields and ultrasound simulations, and in vitro with polyvinyl alcohol cryogel phantoms based on magnetic resonance imaging geometries of carotid plaques. In silico, our results show that the NiV-iMod method: 1) successfully detected and quantified necrotic core inclusions with high positive predictive value (PPV) and sensitivity value (SV) of 81±10% and 91±6%; 2) quantified Young's moduli of necrotic cores, fibrous tissues, and calcium inclusions with mean values of 32±23, 515±30, and 3160±218 kPa (ground true values are 10, 600, and 5000 kPa); and 3) overestimated the cap thickness by . In vitro, the PPV and SV for detecting soft inclusions were 60±21% and 88±9%, and Young's modulus mean values of mimicking lipid, fibrosis, and calcium were 34±19, 193±14, and 649±118 kPa (ground true values are 25±3, 182±21, and 757±87 kPa).
Collapse
|
22
|
Model-based vascular elastography improves the detection of flow-induced carotid artery remodeling in mice. Sci Rep 2017; 7:12081. [PMID: 28935983 PMCID: PMC5608712 DOI: 10.1038/s41598-017-12321-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2017] [Accepted: 09/07/2017] [Indexed: 01/25/2023] Open
Abstract
Increased arterial thickness measured with ultrasound correlates with future cardiovascular events, but conventional ultrasound imaging techniques cannot distinguish between intima, media, or atherosclerotic plaque in the carotid artery. In this work, we evaluated how well vascular elastography can detect intimal changes in a mouse model of carotid remodeling. We ligated the left external and internal branches of the carotid artery of male FVB mice and performed sham operations for 2 weeks. High-resolution ultrasound imaging accurately detected lower blood velocities and low blood volume flow in the carotid arteries after ligation in FVB mice. However, ultrasound could not detect differences in the carotid wall even at 2 weeks post-surgery. The Young’s modulus was measured based on displacements of the carotid artery wall, and Young’s modulus was 2-fold greater in shams at 1 week post ligation, and 3-fold greater 2 weeks after ligation. Finally, the higher Young’s modulus was most associated with higher intimal thickness but not medial or adventitial thickness as measured by histology. In conclusion, we developed a robust ultrasound-based elastography method for early detection of intimal changes in small animals.
Collapse
|
23
|
Verma P, Doyley MM. Revisiting the Cramér Rao Lower Bound for Elastography: Predicting the Performance of Axial, Lateral and Polar Strain Elastograms. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:1780-1796. [PMID: 28655468 DOI: 10.1016/j.ultrasmedbio.2017.05.019] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2016] [Revised: 04/06/2017] [Accepted: 05/21/2017] [Indexed: 06/07/2023]
Abstract
We derived the Cramér Rao lower bound for 2-D estimators employed in quasi-static elastography. To illustrate the theory, we modeled the 2-D point spread function as a sinc-modulated sine pulse in the axial direction and as a sinc function in the lateral direction. We compared theoretical predictions of the variance incurred in displacements and strains when quasi-static elastography was performed under varying conditions (different scanning methods, different configuration of conventional linear array imaging and different-size kernels) with those measured from simulated or experimentally acquired data. We performed studies to illustrate the application of the derived expressions when performing vascular elastography with plane wave and compounded plane wave imaging. Standard deviations in lateral displacements were an order higher than those in axial. Additionally, the derived expressions predicted that peak performance should occur when 2% strain is applied, the same order of magnitude as observed in simulations (1%) and experiments (1%-2%). We assessed how different configurations of conventional linear array imaging (number of active reception and transmission elements) influenced the quality of axial and lateral strain elastograms. The theoretical expressions predicted that 2-D echo tracking should be performed with wide kernels, but the length of the kernels should be selected using knowledge of the magnitude of the applied strain: specifically, longer kernels for small strains (<5%) and shorter kernels for larger strains. Although the general trends of theoretical predictions and experimental observations were similar, biases incurred during beamforming and subsample displacement estimation produced noticeable differences.
Collapse
Affiliation(s)
- Prashant Verma
- Department of Physics and Astronomy, University of Rochester, Rochester, New York, USA
| | - Marvin M Doyley
- Department of Electrical and Computer Engineering, Hajim School of Engineering and Applied Sciences, University of Rochester, Rochester, New York, USA.
| |
Collapse
|
24
|
Carotid Artery Plaque Vulnerability Assessment Using Noninvasive Ultrasound Elastography: Validation With MRI. AJR Am J Roentgenol 2017. [PMID: 28639927 DOI: 10.2214/ajr.16.17176] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
OBJECTIVE Vulnerable and nonvulnerable carotid artery plaques have different tissue morphology and composition that may affect plaque biomechanics. The objective of this study is to evaluate plaque vulnerability with the use of ultrasound noninvasive vascular elastography (NIVE). MATERIALS AND METHODS Thirty-one patients (mean [± SD] age, 69 ± 7 years) with stenosis of the internal carotid artery of 50% or greater were enrolled in this cross-sectional study. Elastography parameters quantifying axial strain, shear strain, and translation motion were used to characterize carotid artery plaques as nonvulnerable, neovascularized, and vulnerable. Maximum axial strain, cumulated axial strain, mean shear strain, cumulated shear strain, cumulated axial translation, and cumulated lateral translations were measured. Cumulated measurements were summed over a cardiac cycle. The ratio of cumulated axial strain to cumulated axial translation was also evaluated. The reference method used to characterize plaques was high-resolution MRI. RESULTS According to MRI, seven plaques were vulnerable, 12 were nonvulnerable without neovascularity, and 12 were nonvulnerable with neovascularity (a precursor of vulnerability). The two parameters cumulated axial translation and the ratio of cumulated axial strain to cumulated axial translation could discriminate between nonvulnerable plaques and vulnerable plaques or determine the presence of neovascularity in nonvulnerable plaques (which was also possible with the mean shear strain parameter). All parameters differed between the non-vulnerable plaque group and the group that combined vulnerable plaques and plaques with neovascularity. The most discriminating parameter for the detection of vulnerable neovascularized plaques was the ratio of cumulated axial strain to cumulated axial translation (expressed as percentage per millimeter) (mean ratio, 39.30%/mm ± 12.80%/mm for nonvulnerable plaques without neovascularity vs 63.79%/mm ± 17.59%/mm for vulnerable plaques and nonvulnerable plaques with neovascularity, p = 0.002), giving an AUC value of 0.886. CONCLUSION The imaging parameters cumulated axial translation and the ratio of cumulated axial strain to cumulated axial translation, as computed using NIVE, were able to discriminate vulnerable carotid artery plaques characterized by MRI from nonvulnerable carotid artery plaques. Consideration of neovascularized plaques improved the performance of NIVE. NIVE may be a valuable alternative to MRI for carotid artery plaque assessment.
Collapse
|
25
|
Zvietcovich F, Rolland JP, Yao J, Meemon P, Parker KJ. Comparative study of shear wave-based elastography techniques in optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:35010. [PMID: 28358943 DOI: 10.1117/1.jbo.22.3.035010] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2016] [Accepted: 03/15/2017] [Indexed: 05/03/2023]
Abstract
We compare five optical coherence elastography techniques able to estimate the shear speed of waves generated by one and two sources of excitation. The first two techniques make use of one piezoelectric actuator in order to produce a continuous shear wave propagation or a tone-burst propagation (TBP) of 400 Hz over a gelatin tissue-mimicking phantom. The remaining techniques utilize a second actuator located on the opposite side of the region of interest in order to create three types of interference patterns: crawling waves, swept crawling waves, and standing waves, depending on the selection of the frequency difference between the two actuators. We evaluated accuracy, contrast to noise ratio, resolution, and acquisition time for each technique during experiments. Numerical simulations were also performed in order to support the experimental findings. Results suggest that in the presence of strong internal reflections, single source methods are more accurate and less variable when compared to the two-actuator methods. In particular, TBP reports the best performance with an accuracy error < 4.1 % . Finally, the TBP was tested in a fresh chicken tibialis anterior muscle with a localized thermally ablated lesion in order to evaluate its performance in biological tissue.
Collapse
Affiliation(s)
- Fernando Zvietcovich
- University of Rochester, Department of Electrical and Computer Engineering, Rochester, New York, United States
| | - Jannick P Rolland
- University of Rochester, The Institute of Optics, Rochester, New York, United States
| | - Jianing Yao
- University of Rochester, The Institute of Optics, Rochester, New York, United States
| | - Panomsak Meemon
- University of Rochester, The Institute of Optics, Rochester, New York, United StatescSuranaree University of Technology, School of Physics, Institute of Science, Nakhon Ratchasima, Thailand
| | - Kevin J Parker
- University of Rochester, Department of Electrical and Computer Engineering, Rochester, New York, United States
| |
Collapse
|
26
|
de Korte CL, Fekkes S, Nederveen AJ, Manniesing R, Hansen HRHG. Review: Mechanical Characterization of Carotid Arteries and Atherosclerotic Plaques. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1613-1623. [PMID: 27249826 DOI: 10.1109/tuffc.2016.2572260] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Cardiovascular disease (CVD) is a leading cause of death and is in the majority of cases due to the formation of atherosclerotic plaques in arteries. Initially, thickening of the inner layer of the arterial wall occurs. Continuation of this process leads to plaque formation. The risk of a plaque to rupture and thus to induce an ischemic event is directly related to its composition. Consequently, characterization of the plaque composition and its proneness to rupture are of crucial importance for risk assessment and treatment strategies. The carotid is an excellent artery to be imaged with ultrasound because of its superficial position. In this review, ultrasound-based methods for characterizing the mechanical properties of the carotid wall and atherosclerotic plaque are discussed. Using conventional echography, the intima media thickness (IMT) can be quantified. There is a wealth of studies describing the relation between IMT and the risk for myocardial infarction and stroke. Also the carotid distensibility can be quantified with ultrasound, providing a surrogate marker for the cross-sectional mechanical properties. Although all these parameters are associated with CVD, they do not easily translate to individual patient risk. Another technique is pulse wave velocity (PWV) assessment, which measures the propagation of the pressure pulse over the arterial bed. PWV has proven to be a marker for global arterial stiffness. Recently, an ultrasound-based method to estimate the local PWV has been introduced, but the clinical effectiveness still needs to be established. Other techniques focus on characterization of plaques. With ultrasound elastography, the strain in the plaque due to the pulsatile pressure can be quantified. This technique was initially developed using intravascular catheters to image coronaries, but recently noninvasive methods were successfully developed. A high correlation between the measured strain and the risk for rupture was established. Acoustic radiation force impulse (ARFI) imaging also provides characterization of local plaque components based on mechanical properties. However, both elastography and ARFI provide an indirect measure of the elastic modulus of tissue. With shear wave imaging, the elastic modulus can be quantified, although the carotid artery is one of the most challenging tissues for this technique due to its size and geometry. Prospective studies still have to establish the predictive value of these techniques for the individual patient. Validation of ultrasound-based mechanical characterization of arteries and plaques remains challenging. Magnetic resonance imaging is often used as the "gold" standard for plaque characterization, but its limited resolution renders only global characterization of the plaque. CT provides information on the vascular tree, the degree of stenosis, and the presence of calcified plaque, while soft plaque characterization remains limited. Histology still is the gold standard, but is available only if tissue is excised. In conclusion, elastographic ultrasound techniques are well suited to characterize the different stages of vascular disease.
Collapse
|
27
|
Hansen HHG, de Borst GJ, Bots ML, Moll FL, Pasterkamp G, de Korte CL. Validation of Noninvasive In Vivo Compound Ultrasound Strain Imaging Using Histologic Plaque Vulnerability Features. Stroke 2016; 47:2770-2775. [PMID: 27686104 DOI: 10.1161/strokeaha.116.014139] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2016] [Accepted: 08/24/2014] [Indexed: 11/16/2022]
Abstract
BACKGROUND AND PURPOSE Carotid plaque rupture is a major cause of stroke. Key issue for risk stratification is early identification of rupture-prone plaques. A noninvasive technique, compound ultrasound strain imaging, was developed providing high-resolution radial deformation/strain images of atherosclerotic plaques. This study aims at in vivo validation of compound ultrasound strain imaging in patients by relating the measured strains to typical features of vulnerable plaques derived from histology after carotid endarterectomy. MATERIALS AND METHODS Strains were measured in 34 severely stenotic (>70%) carotid arteries at the culprit lesion site within 48 hours before carotid endarterectomy. In all cases, the lumen-wall boundary was identifiable on B-mode ultrasound, and the imaged cross-section did not move out of the imaging plane from systole to diastole. After endarterectomy, the plaques were processed using a validated histology analysis technique. RESULTS Locally elevated strain values were observed in regions containing predominantly components related to plaque vulnerability, whereas lower values were observed in fibrous, collagen-rich plaques. The median strain of the inner plaque layer (1 mm thickness) was significantly higher (P<0.01) for (fibro)atheromatous (n=20, strain=0.27%) than that for fibrous plaques (n=14, strain=-0.75%). Also, a significantly larger area percentage of the inner layer revealed strains above 0.5% for (fibro)atheromatous (45.30%) compared with fibrous plaques (31.59%). (Fibro)atheromatous plaques were detected with a sensitivity, specificity, positive predictive value, and negative predictive value of 75%, 86%, 88%, and 71%, respectively. Strain did not significantly correlate with fibrous cap thickness, smooth muscle cell, or macrophage concentration. CONCLUSIONS Compound ultrasound strain imaging allows differentiating (fibro)atheromatous from fibrous carotid artery plaques.
Collapse
Affiliation(s)
- Hendrik H G Hansen
- From the Medical Ultrasound Imaging Center, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands (H.H.G.H., C.L.d.K.); and Department of Vascular Surgery (G.J.d.B., F.L.M.), Julius Center for Health Sciences and Primary Care (M.L.B.), and Laboratory of Experimental Cardiology and Laboratory of Clinical Chemistry (G.P.), University Medical Center Utrecht, The Netherlands.
| | - Gert Jan de Borst
- From the Medical Ultrasound Imaging Center, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands (H.H.G.H., C.L.d.K.); and Department of Vascular Surgery (G.J.d.B., F.L.M.), Julius Center for Health Sciences and Primary Care (M.L.B.), and Laboratory of Experimental Cardiology and Laboratory of Clinical Chemistry (G.P.), University Medical Center Utrecht, The Netherlands
| | - Michiel L Bots
- From the Medical Ultrasound Imaging Center, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands (H.H.G.H., C.L.d.K.); and Department of Vascular Surgery (G.J.d.B., F.L.M.), Julius Center for Health Sciences and Primary Care (M.L.B.), and Laboratory of Experimental Cardiology and Laboratory of Clinical Chemistry (G.P.), University Medical Center Utrecht, The Netherlands
| | - Frans L Moll
- From the Medical Ultrasound Imaging Center, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands (H.H.G.H., C.L.d.K.); and Department of Vascular Surgery (G.J.d.B., F.L.M.), Julius Center for Health Sciences and Primary Care (M.L.B.), and Laboratory of Experimental Cardiology and Laboratory of Clinical Chemistry (G.P.), University Medical Center Utrecht, The Netherlands
| | - Gerard Pasterkamp
- From the Medical Ultrasound Imaging Center, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands (H.H.G.H., C.L.d.K.); and Department of Vascular Surgery (G.J.d.B., F.L.M.), Julius Center for Health Sciences and Primary Care (M.L.B.), and Laboratory of Experimental Cardiology and Laboratory of Clinical Chemistry (G.P.), University Medical Center Utrecht, The Netherlands
| | - Chris L de Korte
- From the Medical Ultrasound Imaging Center, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands (H.H.G.H., C.L.d.K.); and Department of Vascular Surgery (G.J.d.B., F.L.M.), Julius Center for Health Sciences and Primary Care (M.L.B.), and Laboratory of Experimental Cardiology and Laboratory of Clinical Chemistry (G.P.), University Medical Center Utrecht, The Netherlands
| |
Collapse
|
28
|
Mascarenhas EJ, Peters MF, Nijs J, Rutten MC, van de Vosse FN, Lopata RG. Assessment of mechanical properties of porcine aortas under physiological loading conditions using vascular elastography. J Mech Behav Biomed Mater 2016; 59:185-196. [DOI: 10.1016/j.jmbbm.2015.12.009] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2015] [Revised: 12/01/2015] [Accepted: 12/10/2015] [Indexed: 01/11/2023]
|
29
|
Wang X, Mitchell CC, Varghese T, Jackson DC, Rocque BG, Hermann BP, Dempsey RJ. Improved Correlation of Strain Indices with Cognitive Dysfunction with Inclusion of Adventitial Layer with Carotid Plaque. ULTRASONIC IMAGING 2016; 38:194-208. [PMID: 26025578 PMCID: PMC4662918 DOI: 10.1177/0161734615589252] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Plaque instability may lead to chronic embolization, which in turn may contribute to progressive cognitive decline. Accumulated strain tensor indices over a cardiac cycle within a pulsating carotid plaque may be viable biomarkers for the diagnosis of plaque instability. Using plaque-only carotid artery segmentations, we recently demonstrated that impaired cognitive function correlated significantly with maximum axial and lateral strain indices within a localized region of interest in plaque. Inclusion of the adventitial layer focuses our strain or instability measures on the vessel wall-plaque interface hypothesized to be a region with increased shearing forces and measureable instability. A hierarchical block-matching motion tracking algorithm developed in our laboratory was used to estimate accumulated axial, lateral, and shear strain distribution in plaques identified with the plaque-with-adventitia segmentation. Correlations of strain indices to the Repeatable Battery for the Assessment of Neuropsychological Status Total score were performed and compared with previous results. Overall, correlation coefficients (r) and significance (p) values improved for axial, lateral, and shear strain indices. Shear strain indices, however, demonstrated the largest improvement. The Pearson correlation coefficients for maximum shear strain and cognition improved from the previous plaque-only analyses of -0.432 and -0.345 to -0.795 and -0.717 with the plaque-with-adventitia segmentation for the symptomatic group and for all patients combined, respectively. Our results demonstrate the advantage of including adventitia for ultrasound carotid strain imaging providing improved association to parameters assessing cognitive impairment in patients. This supports theories of the importance of the vessel wall plaque interface in the pathophysiology of embolic disease.
Collapse
Affiliation(s)
- X Wang
- Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, Madison, WI, USA
| | - C C Mitchell
- Department of Medicine, University of Wisconsin-Madison, Madison School of Medicine and Public Health, WI, USA
| | - T Varghese
- Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, Madison, WI, USA
| | - D C Jackson
- Department of Neurology, University of Wisconsin-Madison, Madison School of Medicine and Public Health, WI, USA
| | - B G Rocque
- Department of Neurological Surgery, University of Wisconsin-Madison School of Medicine and Public Health, Madison, WI, USA
| | - B P Hermann
- Department of Neurology, University of Wisconsin-Madison, Madison School of Medicine and Public Health, WI, USA
| | - R J Dempsey
- Department of Neurological Surgery, University of Wisconsin-Madison School of Medicine and Public Health, Madison, WI, USA
| |
Collapse
|
30
|
Boekhoven RW, Peters MFJ, Rutten MCM, van Sambeek MR, van de Vosse FN, Lopata RGP. Inflation and Bi-Axial Tensile Testing of Healthy Porcine Carotid Arteries. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:574-585. [PMID: 26598396 DOI: 10.1016/j.ultrasmedbio.2015.09.019] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2014] [Revised: 09/16/2015] [Accepted: 09/16/2015] [Indexed: 06/05/2023]
Abstract
Knowledge of the intrinsic material properties of healthy and diseased arterial tissue components is of great importance in diagnostics. This study describes an in vitro comparison of 13 porcine carotid arteries using inflation testing combined with functional ultrasound and bi-axial tensile testing. The measured tissue behavior was described using both a linear, but geometrically non-linear, one-parameter (neo-Hookean) model and a two-parameter non-linear (Demiray) model. The shear modulus estimated using the linear model resulted in good agreement between the ultrasound and tensile testing methods, GUS = 25 ± 5.7 kPa and GTT = 23 ± 5.4 kPa. No significant correspondence was observed for the non-linear model aUS = 1.0 ± 2.7 kPa vs. aTT = 17 ± 8.8 kPa, p ∼ 0); however, the exponential parameters were in correspondence (bUS = 12 ± 4.2 vs. bTT = 10 ± 1.7, p > 0.05). Estimation of more complex models in vivo is cumbersome considering the sensitivity of the model parameters to small changes in measurement data and the absence of intraluminal pressure data, endorsing the use of a simple, linear model in vivo.
Collapse
Affiliation(s)
- Renate W Boekhoven
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Mathijs F J Peters
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Marcel C M Rutten
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Marc R van Sambeek
- Vascular Surgery, Catharina Hospital Eindhoven, Eindhoven, The Netherlands
| | - Frans N van de Vosse
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Richard G P Lopata
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| |
Collapse
|
31
|
Apostolakis IZ, Nandlall SD, Konofagou EE. Piecewise Pulse Wave Imaging (pPWI) for Detection and Monitoring of Focal Vascular Disease in Murine Aortas and Carotids In Vivo. IEEE TRANSACTIONS ON MEDICAL IMAGING 2016; 35:13-28. [PMID: 26168432 PMCID: PMC4703464 DOI: 10.1109/tmi.2015.2453194] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Atherosclerosis and Abdominal Aortic Aneurysms (AAAs) are two common vascular diseases associated with mechanical changes in the arterial wall. Pulse Wave Imaging (PWI), a technique developed by our group to assess and quantify the mechanical properties of the aortic wall in vivo, may provide valuable diagnostic information. This work implements piecewise PWI (pPWI), an enhanced version of PWI designed for focal vascular diseases. Localized, sub-regional PWVs and PWI moduli ( EPWI ) were estimated within 2-4 mm wall segments of murine normal, atherosclerotic and aneurysmal arteries. Overall, stiffness was found to increase in the atherosclerotic cases. The mean sub-regional PWV was found to be 2.57±0.18 m/s for the normal aortas (n = 7) with a corresponding mean EPWI of 43.82±5.86 kPa. A significant increase ( (p ≤ 0.001)) in the group means of the sub-regional PWVs was found between the normal aortas and the aortas of mice on high-fat diet for 20 ( 3.30±0.36 m/s) and 30 weeks ( 3.56±0.29 m/s). The mean of the sub-regional PWVs ( 1.57±0.78 m/s) and EPWI values ( 19.23±15.47 kPa) decreased significantly in the aneurysmal aortas (p ≤ 0.05) . Furthermore, the mean coefficient of determination (r(2)) of the normal aortas was significantly higher (p ≤ 0.05) than those of the aneurysmal and atherosclerotic cases. These findings demonstrated that pPWI may be able to provide useful biomarkers for monitoring focal vascular diseases.
Collapse
Affiliation(s)
| | - Sacha D. Nandlall
- Department of Biomedical Engineering Columbia University, New York, NY 10027 USA
| | - Elisa E. Konofagou
- Departments of Biomedical Engineering and Radiology, Columbia University, New York, NY 10027 USA ()
| |
Collapse
|
32
|
Wang Z, Liu N, Zhang L, Li X, Han X, Peng Y, Dang M, Sun L, Tian J. Real-Time Elastography Visualization and Histopathological Characterization of Rabbit Atherosclerotic Carotid Arteries. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:176-184. [PMID: 26381920 DOI: 10.1016/j.ultrasmedbio.2015.08.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2015] [Revised: 07/21/2015] [Accepted: 08/08/2015] [Indexed: 06/05/2023]
Abstract
To evaluate the feasibility of non-invasive vascular real-time elastography imaging (RTE) in visualizing the composition of rabbit carotid atherosclerotic plaque as determined by histopathology, a rabbit model of accelerated carotid atherosclerosis was used. Thirty rabbits were randomly divided into two groups of 15 rabbits each. The first group was fed a cholesterol-rich diet and received balloon-induced injury the left common carotid artery endothelium, whereas the second group only received a cholesterol-rich diet. The rabbits were all examined in vivo with HITACHI non-invasive vascular real-time elastography (Hi-RTE) at baseline and 12 wk, and results from the elastography were compared with American Heart Association histologic classifications. Hi-RTE and the American Heart Association histologic classifications had good agreement, with weighted Cohen's kappa (95% confidence internal) of 0.785 (0.649-0.920). Strains of segmented plaques that were stained in different colors were statistically different (p < 0.0001). The sensitivity and specificity of elastograms for detecting a lipid core were 95.5% and 61.5%, respectively, and the area under the receiver operating characteristic curve was 0.789, with a 95% confidence interval of 0.679 to 0.876. This study is the first to indicate the feasibility of utilizing Hi-RTE in visualizing normal and atherosclerotic rabbit carotid arteries non-invasively. This affordable and reliable method can be widely applied in research of both animal and human peripheral artery atherosclerosis.
Collapse
Affiliation(s)
- ZhenZhen Wang
- Department of Ultrasound, Second Affiliated Hospital of Harbin Medical University, Harbin, China
| | - NaNa Liu
- Department of Ultrasound, Second Affiliated Hospital of Harbin Medical University, Harbin, China
| | - LiFeng Zhang
- Department of Ultrasound, DaQing Fourth Hospital, DaQing, China
| | - XiaoYing Li
- Department of Ultrasound, Second Affiliated Hospital of Harbin Medical University, Harbin, China
| | - XueSong Han
- Department of Ultrasound, Second Affiliated Hospital of Harbin Medical University, Harbin, China
| | - YanQing Peng
- Department of Ultrasound, Second Affiliated Hospital of Harbin Medical University, Harbin, China
| | - MeiZheng Dang
- Department of Ultrasound, Second Affiliated Hospital of Harbin Medical University, Harbin, China
| | - LiTao Sun
- Department of Ultrasound, Second Affiliated Hospital of Harbin Medical University, Harbin, China.
| | - JiaWei Tian
- Department of Ultrasound, Second Affiliated Hospital of Harbin Medical University, Harbin, China.
| |
Collapse
|
33
|
Salloum E, Bertrand-Grenier A, Lerouge S, Kauffman C, Héon H, Therasse E, Salazkin I, Roy Cardinal MH, Cloutier G, Soulez G. Endovascular Repair of Abdominal Aortic Aneurysm: Follow-up with Noninvasive Vascular Elastography in a Canine Model. Radiology 2015; 279:410-9. [PMID: 26690905 DOI: 10.1148/radiol.2015142098] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To assess the ability of noninvasive vascular elastography (NIVE) to help characterize endoleaks and thrombus organization in a canine model of abdominal aortic aneurysm after endovascular aneurysm repair with stent-grafts, in comparison with computed tomography (CT) and pathologic examination findings. MATERIALS AND METHODS All protocols were approved by the Animal Care Committee in accordance with the guidelines of the Canadian Council of Animal Care. Stent-grafts were implanted in a group of 18 dogs with aneurysms created in the abdominal aorta. Type I endoleak was created in four aneurysms; type II endoleak, in 13 aneurysms; and no endoleak, in one aneurysm. Doppler ultrasonography and NIVE examinations were performed at baseline and at 1-week, 1-month, 3-month, and 6-month follow-up. Angiography, CT, and macroscopic tissue examination were performed at sacrifice. Strain values were computed by using the Lagrangian speckle model estimator. Areas of endoleak, solid organized thrombus, and fresh thrombus were identified and segmented by comparing the results of CT and macroscopic tissue examination. Strain values were compared by using the Wilcoxon rank-sum and Kruskal-Wallis tests. RESULTS All stent-grafts were successfully deployed, and endoleaks were clearly depicted in the last follow-up elastography examinations. Maximal axial strains over consecutive heart cycles in endoleak, organized thrombus, and fresh thrombus areas were 0.78% ± 0.22, 0.23% ± 0.02, 0.10% ± 0.04, respectively. Strain values were significantly different between endoleak and organized or fresh thrombus areas (P < .000) and between organized and fresh thrombus areas (P < .0002). No correlation was found between strain values and type of endoleak, sac pressure, endoleak size, and aneurysm size. CONCLUSION NIVE may be able to help characterize endoleak and thrombus organization, regardless of the size, pressure, and type of endoleak.
Collapse
Affiliation(s)
- Eli Salloum
- From the Department of Radiology, Radio-Oncology and Nuclear Medicine, and Institute of Biomedical Engineering, Université de Montréal, Montreal, Quebec, Canada (E.S., A.B., C.K., E.T., G.C., G.S.); Department of Radiology, Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada (E.T., G.S.); Centre de Recherche de l'Université de Montréal, 900 rue Saint-Denis, Montreal, QC, Canada H2X 0A9 (E.S., A.B., S.L., C.K., H.H., E.T., I.S., M.H.R.C., G.C., G.S.); Laboratory of Biorheology and Medical Ultrasonics (E.S., A.B., M.H.R.C., G.C.) and Clinical Image Processing Laboratory (E.S., A.B., C.K., G.S.), Centre de Recherche de l'Université de Montréal, Montreal, Quebec, Canada; and Department of Mechanical Engineering, École de Technologie Supérieure, Montreal, Quebec, Canada (S.L.)
| | - Antony Bertrand-Grenier
- From the Department of Radiology, Radio-Oncology and Nuclear Medicine, and Institute of Biomedical Engineering, Université de Montréal, Montreal, Quebec, Canada (E.S., A.B., C.K., E.T., G.C., G.S.); Department of Radiology, Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada (E.T., G.S.); Centre de Recherche de l'Université de Montréal, 900 rue Saint-Denis, Montreal, QC, Canada H2X 0A9 (E.S., A.B., S.L., C.K., H.H., E.T., I.S., M.H.R.C., G.C., G.S.); Laboratory of Biorheology and Medical Ultrasonics (E.S., A.B., M.H.R.C., G.C.) and Clinical Image Processing Laboratory (E.S., A.B., C.K., G.S.), Centre de Recherche de l'Université de Montréal, Montreal, Quebec, Canada; and Department of Mechanical Engineering, École de Technologie Supérieure, Montreal, Quebec, Canada (S.L.)
| | - Sophie Lerouge
- From the Department of Radiology, Radio-Oncology and Nuclear Medicine, and Institute of Biomedical Engineering, Université de Montréal, Montreal, Quebec, Canada (E.S., A.B., C.K., E.T., G.C., G.S.); Department of Radiology, Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada (E.T., G.S.); Centre de Recherche de l'Université de Montréal, 900 rue Saint-Denis, Montreal, QC, Canada H2X 0A9 (E.S., A.B., S.L., C.K., H.H., E.T., I.S., M.H.R.C., G.C., G.S.); Laboratory of Biorheology and Medical Ultrasonics (E.S., A.B., M.H.R.C., G.C.) and Clinical Image Processing Laboratory (E.S., A.B., C.K., G.S.), Centre de Recherche de l'Université de Montréal, Montreal, Quebec, Canada; and Department of Mechanical Engineering, École de Technologie Supérieure, Montreal, Quebec, Canada (S.L.)
| | - Claude Kauffman
- From the Department of Radiology, Radio-Oncology and Nuclear Medicine, and Institute of Biomedical Engineering, Université de Montréal, Montreal, Quebec, Canada (E.S., A.B., C.K., E.T., G.C., G.S.); Department of Radiology, Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada (E.T., G.S.); Centre de Recherche de l'Université de Montréal, 900 rue Saint-Denis, Montreal, QC, Canada H2X 0A9 (E.S., A.B., S.L., C.K., H.H., E.T., I.S., M.H.R.C., G.C., G.S.); Laboratory of Biorheology and Medical Ultrasonics (E.S., A.B., M.H.R.C., G.C.) and Clinical Image Processing Laboratory (E.S., A.B., C.K., G.S.), Centre de Recherche de l'Université de Montréal, Montreal, Quebec, Canada; and Department of Mechanical Engineering, École de Technologie Supérieure, Montreal, Quebec, Canada (S.L.)
| | - Hélène Héon
- From the Department of Radiology, Radio-Oncology and Nuclear Medicine, and Institute of Biomedical Engineering, Université de Montréal, Montreal, Quebec, Canada (E.S., A.B., C.K., E.T., G.C., G.S.); Department of Radiology, Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada (E.T., G.S.); Centre de Recherche de l'Université de Montréal, 900 rue Saint-Denis, Montreal, QC, Canada H2X 0A9 (E.S., A.B., S.L., C.K., H.H., E.T., I.S., M.H.R.C., G.C., G.S.); Laboratory of Biorheology and Medical Ultrasonics (E.S., A.B., M.H.R.C., G.C.) and Clinical Image Processing Laboratory (E.S., A.B., C.K., G.S.), Centre de Recherche de l'Université de Montréal, Montreal, Quebec, Canada; and Department of Mechanical Engineering, École de Technologie Supérieure, Montreal, Quebec, Canada (S.L.)
| | - Eric Therasse
- From the Department of Radiology, Radio-Oncology and Nuclear Medicine, and Institute of Biomedical Engineering, Université de Montréal, Montreal, Quebec, Canada (E.S., A.B., C.K., E.T., G.C., G.S.); Department of Radiology, Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada (E.T., G.S.); Centre de Recherche de l'Université de Montréal, 900 rue Saint-Denis, Montreal, QC, Canada H2X 0A9 (E.S., A.B., S.L., C.K., H.H., E.T., I.S., M.H.R.C., G.C., G.S.); Laboratory of Biorheology and Medical Ultrasonics (E.S., A.B., M.H.R.C., G.C.) and Clinical Image Processing Laboratory (E.S., A.B., C.K., G.S.), Centre de Recherche de l'Université de Montréal, Montreal, Quebec, Canada; and Department of Mechanical Engineering, École de Technologie Supérieure, Montreal, Quebec, Canada (S.L.)
| | - Igor Salazkin
- From the Department of Radiology, Radio-Oncology and Nuclear Medicine, and Institute of Biomedical Engineering, Université de Montréal, Montreal, Quebec, Canada (E.S., A.B., C.K., E.T., G.C., G.S.); Department of Radiology, Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada (E.T., G.S.); Centre de Recherche de l'Université de Montréal, 900 rue Saint-Denis, Montreal, QC, Canada H2X 0A9 (E.S., A.B., S.L., C.K., H.H., E.T., I.S., M.H.R.C., G.C., G.S.); Laboratory of Biorheology and Medical Ultrasonics (E.S., A.B., M.H.R.C., G.C.) and Clinical Image Processing Laboratory (E.S., A.B., C.K., G.S.), Centre de Recherche de l'Université de Montréal, Montreal, Quebec, Canada; and Department of Mechanical Engineering, École de Technologie Supérieure, Montreal, Quebec, Canada (S.L.)
| | - Marie-Hélène Roy Cardinal
- From the Department of Radiology, Radio-Oncology and Nuclear Medicine, and Institute of Biomedical Engineering, Université de Montréal, Montreal, Quebec, Canada (E.S., A.B., C.K., E.T., G.C., G.S.); Department of Radiology, Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada (E.T., G.S.); Centre de Recherche de l'Université de Montréal, 900 rue Saint-Denis, Montreal, QC, Canada H2X 0A9 (E.S., A.B., S.L., C.K., H.H., E.T., I.S., M.H.R.C., G.C., G.S.); Laboratory of Biorheology and Medical Ultrasonics (E.S., A.B., M.H.R.C., G.C.) and Clinical Image Processing Laboratory (E.S., A.B., C.K., G.S.), Centre de Recherche de l'Université de Montréal, Montreal, Quebec, Canada; and Department of Mechanical Engineering, École de Technologie Supérieure, Montreal, Quebec, Canada (S.L.)
| | - Guy Cloutier
- From the Department of Radiology, Radio-Oncology and Nuclear Medicine, and Institute of Biomedical Engineering, Université de Montréal, Montreal, Quebec, Canada (E.S., A.B., C.K., E.T., G.C., G.S.); Department of Radiology, Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada (E.T., G.S.); Centre de Recherche de l'Université de Montréal, 900 rue Saint-Denis, Montreal, QC, Canada H2X 0A9 (E.S., A.B., S.L., C.K., H.H., E.T., I.S., M.H.R.C., G.C., G.S.); Laboratory of Biorheology and Medical Ultrasonics (E.S., A.B., M.H.R.C., G.C.) and Clinical Image Processing Laboratory (E.S., A.B., C.K., G.S.), Centre de Recherche de l'Université de Montréal, Montreal, Quebec, Canada; and Department of Mechanical Engineering, École de Technologie Supérieure, Montreal, Quebec, Canada (S.L.)
| | - Gilles Soulez
- From the Department of Radiology, Radio-Oncology and Nuclear Medicine, and Institute of Biomedical Engineering, Université de Montréal, Montreal, Quebec, Canada (E.S., A.B., C.K., E.T., G.C., G.S.); Department of Radiology, Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada (E.T., G.S.); Centre de Recherche de l'Université de Montréal, 900 rue Saint-Denis, Montreal, QC, Canada H2X 0A9 (E.S., A.B., S.L., C.K., H.H., E.T., I.S., M.H.R.C., G.C., G.S.); Laboratory of Biorheology and Medical Ultrasonics (E.S., A.B., M.H.R.C., G.C.) and Clinical Image Processing Laboratory (E.S., A.B., C.K., G.S.), Centre de Recherche de l'Université de Montréal, Montreal, Quebec, Canada; and Department of Mechanical Engineering, École de Technologie Supérieure, Montreal, Quebec, Canada (S.L.)
| |
Collapse
|
34
|
Porée J, Garcia D, Chayer B, Ohayon J, Cloutier G. Noninvasive Vascular Elastography With Plane Strain Incompressibility Assumption Using Ultrafast Coherent Compound Plane Wave Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2015; 34:2618-2631. [PMID: 26625341 DOI: 10.1109/tmi.2015.2450992] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Plane strain tensor estimation using non-invasive vascular ultrasound elastography (NIVE) can be difficult to achieve using conventional focus beamforming due to limited lateral resolution and frame rate. Recent developments in compound plane wave (CPW) imaging have led to high speed and high resolution imaging. In this study, we present the performance of NIVE using coherent CPW. We show the impact of CPW beamforming on strain estimates compared to conventional focus sequences. To overcome the inherent variability of lateral strains, associated with the low lateral resolution of linear array transducers, we use the plane strain incompressibility to constrain the estimator. Taking advantage of the approximate tenfold increase in frame rate of CPW compared with conventional focus imaging, we introduce a time-ensemble estimation approach to further improve the elastogram quality. By combining CPW imaging with the constrained Lagrangian speckle model estimator, we observe an increase in elastography quality (∼ 10 dB both in signal-to-noise and contrast-to-noise ratios) over a wide range of applied strains (0.02 to 3.2%).
Collapse
|
35
|
Pan X, Liu K, Shao J, Gao J, Huang L, Bai J, Luo J. Performance comparison of rigid and affine models for motion estimation using ultrasound radio-frequency signals. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2015; 62:1928-1943. [PMID: 26559623 DOI: 10.1109/tuffc.2015.007245] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Tissue motion estimation is widely used in many ultrasound techniques. Rigid-model-based and nonrigid-modelbased methods are two main groups of space-domain methods of tissue motion estimation. The affine model is one of the commonly used nonrigid models. The performances of the rigid model and affine model have not been compared on ultrasound RF signals, which have been demonstrated to obtain higher accuracy, precision, and resolution in motion estimation compared with B-mode images. In this study, three methods, i.e., the normalized cross-correlation method with rigid model (NCC), the optical flow method with rigid model (OFRM), and the optical flow method with affine model (OFAM), are compared using ultrasound RF signals, rather than the B-mode images used in previous studies. Simulations, phantom, and in vivo experiments are conducted to make the comparison. In the simulations, the root-mean-square errors (RMSEs) of axial and lateral displacements and strains are used to assess the accuracy of motion estimation, and the elastographic signal-tonoise ratio (SNRe) and contrast-to-noise ratio (CNRe) are used to evaluate the quality of axial strain images. In the phantom experiments, the registration error between the pre- and postdeformation RF signals, as well as the SNRe and CNRe of axial strain images, are utilized as the evaluation criteria. In the in vivo experiments, the registration error is used to evaluate the estimation performance. The results show that the affinemodel- based method (i.e., OFAM) obtains the lowest RMSE or registration error and the highest SNRe and CNRe among all the methods. The affine model is demonstrated to be superior to the rigid model in motion estimation based on RF signals.
Collapse
|
36
|
Casella IB, Fukushima RB, Marques ABDA, Cury MVM, Presti C. Comparison between a new computer program and the reference software for gray-scale median analysis of atherosclerotic carotid plaques. JOURNAL OF CLINICAL ULTRASOUND : JCU 2015; 43:194-198. [PMID: 24865562 DOI: 10.1002/jcu.22178] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2013] [Revised: 02/09/2014] [Accepted: 05/06/2014] [Indexed: 06/03/2023]
Abstract
PURPOSE To compare a new dedicated software program and Adobe Photoshop for gray-scale median (GSM) analysis of B-mode images of carotid plaques. METHODS A series of 42 carotid plaques generating ≥50% diameter stenosis was evaluated by a single observer. The best segment for visualization of internal carotid artery plaque was identified on a single longitudinal view and images were recorded in JPEG format. Plaque analysis was performed by both programs. After normalization of image intensity (blood = 0, adventitial layer = 190), histograms were obtained after manual delineation of plaque. Results were compared with nonparametric Wilcoxon signed rank test and Kendall tau-b correlation analysis. RESULTS GSM ranged from 00 to 100 with Adobe Photoshop and from 00 to 96 with IMTPC, with a high grade of similarity between image pairs, and a highly significant correlation (R = 0.94, p < .0001). CONCLUSIONS IMTPC software appears suitable for the GSM analysis of carotid plaques.
Collapse
Affiliation(s)
- Ivan Benaduce Casella
- Department of Vascular Surgery, Clinics Hospital of the Faculty of Medicine of São Paulo University, Av. Dr. Eneas Carvalho de Aguiar, 255, 05403-000, São Paulo, SP, Brazil
| | | | | | | | | |
Collapse
|
37
|
Liu F, Yong Q, Zhang Q, Liu P, Yang Y. Real-time tissue elastography for the detection of vulnerable carotid plaques in patients undergoing endarterectomy: a pilot study. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:705-712. [PMID: 25619789 DOI: 10.1016/j.ultrasmedbio.2014.10.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2014] [Revised: 09/19/2014] [Accepted: 10/18/2014] [Indexed: 06/04/2023]
Abstract
We examined the utility of ultrasonic real-time tissue elastography (RTE) and conventional B-mode ultrasound (US) in the detection of vulnerable carotid atherosclerotic plaques. This prospective study comprised 19 patients scheduled for carotid endarterectomy. Results obtained from pre-operative RTE and B-mode US and post-operative pathology were compared. RTE encoded low, average and high deformability as blue, green and red, respectively. Tissue hardness was scored on a 5-point scale, and relative strains were calculated. The relative strain was 1.12 ± 0.14 for fibrous plaques (n = 4), 0.28 ± 0.07 for atherosclerotic plaques (n = 5), 0.47 ± 0.31 for intraplaque hemorrhage/thrombosis (n = 5) and 0.98 ± 1.04 for complex plaques (n = 5). The sensitivity, specificity and accuracy of detection of vulnerable plaques were 25%, 100% and 84.2% for B-mode US, 50%, 100% and 89.4% for RTE and 62.5%, 100% and 94.7% for the combination. Ultrasonic RTE is a potential candidate for a non-invasive and effective approach to identify vulnerable atherosclerotic plaques in the carotid artery.
Collapse
Affiliation(s)
- Fengju Liu
- Department of Ultrasound, Capital Medical University Affiliated Beijing Anzhen Hospital, Beijing Institute of Heart, Lung and Blood Vessel Diseases, Beijing, China
| | - Qiang Yong
- Department of Ultrasound, Capital Medical University Affiliated Beijing Anzhen Hospital, Beijing Institute of Heart, Lung and Blood Vessel Diseases, Beijing, China.
| | - Qinyi Zhang
- Stroke Center, Capital Medical University Affiliated Beijing Anzhen Hospital, Beijing Institute of Heart, Lung and Blood Vessel Diseases, Beijing, China
| | - Peng Liu
- Department of Cardiovascular Surgery, China-Japan Friendship Hospital, Beijing, China
| | - Yuguang Yang
- Department of Cardiovascular Surgery, China-Japan Friendship Hospital, Beijing, China
| |
Collapse
|
38
|
Larsson M, Heyde B, Kremer F, Brodin LÅ, D'hooge J. Ultrasound speckle tracking for radial, longitudinal and circumferential strain estimation of the carotid artery--an in vitro validation via sonomicrometry using clinical and high-frequency ultrasound. ULTRASONICS 2015; 56:399-408. [PMID: 25262347 DOI: 10.1016/j.ultras.2014.09.005] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2014] [Revised: 08/14/2014] [Accepted: 09/09/2014] [Indexed: 06/03/2023]
Abstract
Ultrasound speckle tracking for carotid strain assessment has in the past decade gained interest in studies of arterial stiffness and cardiovascular diseases. The aim of this study was to validate and directly contrast carotid strain assessment by speckle tracking applied on clinical and high-frequency ultrasound images in vitro. Four polyvinyl alcohol phantoms mimicking the carotid artery were constructed with different mechanical properties and connected to a pump generating carotid flow profiles. Gray-scale ultrasound long- and short-axis images of the phantoms were obtained using a standard clinical ultrasound system, Vivid 7 (GE Healthcare, Horten, Norway) and a high-frequency ultrasound system, Vevo 2100 (FUJIFILM, VisualSonics, Toronto, Canada) with linear-array transducers (12L/MS250). Radial, longitudinal and circumferential strains were estimated using an in-house speckle tracking algorithm and compared with reference strain acquired by sonomicrometry. Overall, the estimated strain corresponded well with the reference strain. The correlation between estimated peak strain in clinical ultrasound images and reference strain was 0.91 (p<0.001) for radial strain, 0.73 (p<0.001) for longitudinal strain and 0.90 (p<0.001) for circumferential strain and for high-frequency ultrasound images 0.95 (p<0.001) for radial strain, 0.93 (p<0.001) for longitudinal strain and 0.90 (p<0.001) for circumferential strain. A significant larger bias and root mean square error was found for circumferential strain estimation on clinical ultrasound images compared to high frequency ultrasound images, but no significant difference in bias and root mean square error was found for radial and longitudinal strain when comparing estimation on clinical and high-frequency ultrasound images. The agreement between sonomicrometry and speckle tracking demonstrates that carotid strain assessment by ultrasound speckle tracking is feasible.
Collapse
Affiliation(s)
- Matilda Larsson
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Alfred Nobels Allé 10, 141 52 Huddinge, Sweden; Lab on Cardiovascular Imaging & Dynamics, KU Leuven, Campus Gasthuisberg O&N1, Herestraat 49 box 911, 3000 Leuven, Belgium.
| | - Brecht Heyde
- Lab on Cardiovascular Imaging & Dynamics, KU Leuven, Campus Gasthuisberg O&N1, Herestraat 49 box 911, 3000 Leuven, Belgium
| | - Florence Kremer
- Lab on Cardiovascular Imaging & Dynamics, KU Leuven, Campus Gasthuisberg O&N1, Herestraat 49 box 911, 3000 Leuven, Belgium
| | - Lars-Åke Brodin
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Alfred Nobels Allé 10, 141 52 Huddinge, Sweden
| | - Jan D'hooge
- Lab on Cardiovascular Imaging & Dynamics, KU Leuven, Campus Gasthuisberg O&N1, Herestraat 49 box 911, 3000 Leuven, Belgium
| |
Collapse
|
39
|
Larsson M, Verbrugghe P, Smoljkić M, Verhoeven J, Heyde B, Famaey N, Herijgers P, D’hooge J. Strain assessment in the carotid artery wall using ultrasound speckle tracking: validation in a sheep model. Phys Med Biol 2015; 60:1107-23. [DOI: 10.1088/0031-9155/60/3/1107] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
40
|
Widman E, Caidahl K, Heyde B, D'hooge J, Larsson M. Ultrasound speckle tracking strain estimation of in vivo carotid artery plaque with in vitro sonomicrometry validation. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:77-88. [PMID: 25308946 DOI: 10.1016/j.ultrasmedbio.2014.06.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2014] [Revised: 06/03/2014] [Accepted: 06/23/2014] [Indexed: 06/04/2023]
Abstract
Our objective was to validate a previously developed speckle tracking (ST) algorithm to assess strain in common carotid artery plaques. Radial and longitudinal strain was measured in common carotid artery gel phantoms with a plaque-mimicking inclusion using an in-house ST algorithm and sonomicrometry. Moreover, plaque strain by ST for seven patients (77 ± 6 y) with carotid atherosclerosis was compared with a quantitative visual assessment by two experienced physicians. In vitro, good correlation existed between ST and sonomicrometry peak strains, both radially (r = 0.96, p < 0.001) and longitudinally (r = 0.75, p < 0.01). In vivo, greater pulse pressure-adjusted radial and longitudinal strains were found in echolucent plaques than in echogenic plaques. This illustrates the feasibility of ultrasound ST strain estimation in plaques and the possibility of characterizing plaques using ST strain in vivo.
Collapse
Affiliation(s)
- Erik Widman
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden.
| | - Kenneth Caidahl
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
| | - Brecht Heyde
- Cardiovascular Imaging & Dynamics, Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| | - Jan D'hooge
- Cardiovascular Imaging & Dynamics, Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| | - Matilda Larsson
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden; Cardiovascular Imaging & Dynamics, Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| |
Collapse
|
41
|
Hai P, Zhou Y, Liang J, Li C, Wang LV. Photoacoustic tomography of vascular compliance in humans. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:126008. [PMID: 26720875 PMCID: PMC4684588 DOI: 10.1117/1.jbo.20.12.126008] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2015] [Accepted: 11/19/2015] [Indexed: 05/04/2023]
Abstract
Characterization of blood vessel elastic properties can help in detecting thrombosis and preventing life-threatening conditions such as acute myocardial infarction or stroke. Vascular elastic photoacoustic tomography (VE-PAT) is proposed to measure blood vessel compliance in humans. Implemented on a linear-array-based photoacoustic computed tomography system, VE-PAT can quantify blood vessel compliance changes due to simulated thrombosis and occlusion. The feasibility of the VE-PAT system was first demonstrated by measuring the strains under uniaxial loading in perfused blood vessel phantoms and quantifying their compliance changes due to the simulated thrombosis. The VE-PAT system detected a decrease in the compliances of blood vessel phantoms with simulated thrombosis, which was validated by a standard compression test. The VE-PAT system was then applied to assess blood vessel compliance in a human subject. Experimental results showed a decrease in compliance when an occlusion occurred downstream from the measurement point in the blood vessels, demonstrating VE-PAT’s potential for clinical thrombosis detection.
Collapse
Affiliation(s)
- Pengfei Hai
- Washington University in St. Louis, Department of Biomedical Engineering, Optical Imaging Laboratory, One Brookings Drive, St. Louis, Missouri 63130, United States
| | - Yong Zhou
- Washington University in St. Louis, Department of Biomedical Engineering, Optical Imaging Laboratory, One Brookings Drive, St. Louis, Missouri 63130, United States
| | - Jinyang Liang
- Washington University in St. Louis, Department of Biomedical Engineering, Optical Imaging Laboratory, One Brookings Drive, St. Louis, Missouri 63130, United States
| | - Chiye Li
- Washington University in St. Louis, Department of Biomedical Engineering, Optical Imaging Laboratory, One Brookings Drive, St. Louis, Missouri 63130, United States
| | - Lihong V. Wang
- Washington University in St. Louis, Department of Biomedical Engineering, Optical Imaging Laboratory, One Brookings Drive, St. Louis, Missouri 63130, United States
- Address all correspondence to: Lihong V. Wang, E-mail:
| |
Collapse
|
42
|
Lopata RGP, Peters MFJ, Nijs J, Oomens CWJ, Rutten MCM, van de Vosse FN. Vascular elastography: a validation study. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:1882-1895. [PMID: 24798385 DOI: 10.1016/j.ultrasmedbio.2014.02.029] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2013] [Revised: 01/13/2014] [Accepted: 02/23/2014] [Indexed: 06/03/2023]
Abstract
Vascular elastography techniques are promising tools for mechanical characterization of diseased arteries. These techniques are usually validated with simulations or phantoms or by comparing results with histology or other imaging modalities. In the study described here, vascular elastography was applied to porcine aortas in vitro during inflation testing (n = 10) and results were compared with those of standard bi-axial tensile testing, a technique that directly measures the force applied to the tissue. A neo-Hookean model was fit to the stress-strain data, valid for large deformations. Results indicated good correspondence between the two techniques, with GUS = 110 ± 11 kPa and GTT = 108 ± 10 kPa for ultrasound and tensile testing, respectively. Bland-Altman analysis revealed little bias (GUS-GTT = 2 ± 20 kPa). The next step will be the application of a non-linear material model that is also adaptable for in vivo measurements.
Collapse
Affiliation(s)
- Richard G P Lopata
- Cardiovascular Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| | - Mathijs F J Peters
- Cardiovascular Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Jan Nijs
- Department of Cardiac Surgery, University Hospital Brussels, Brussels, Belgium
| | - Cees W J Oomens
- Soft Tissue Biomechanics & Engineering, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Marcel C M Rutten
- Cardiovascular Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Frans N van de Vosse
- Cardiovascular Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
43
|
Razani M, Luk TW, Mariampillai A, Siegler P, Kiehl TR, Kolios MC, Yang VX. Optical coherence tomography detection of shear wave propagation in inhomogeneous tissue equivalent phantoms and ex-vivo carotid artery samples. BIOMEDICAL OPTICS EXPRESS 2014; 5:895-906. [PMID: 24688822 PMCID: PMC3959849 DOI: 10.1364/boe.5.000895] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2013] [Revised: 01/16/2014] [Accepted: 02/19/2014] [Indexed: 05/04/2023]
Abstract
In this work, we explored the potential of measuring shear wave propagation using optical coherence elastography (OCE) in an inhomogeneous phantom and carotid artery samples based on a swept-source optical coherence tomography (OCT) system. Shear waves were generated using a piezoelectric transducer transmitting sine-wave bursts of 400 μs duration, applying acoustic radiation force (ARF) to inhomogeneous phantoms and carotid artery samples, synchronized with a swept-source OCT (SS-OCT) imaging system. The phantoms were composed of gelatin and titanium dioxide whereas the carotid artery samples were embedded in gel. Differential OCT phase maps, measured with and without the ARF, detected the microscopic displacement generated by shear wave propagation in these phantoms and samples of different stiffness. We present the technique for calculating tissue mechanical properties by propagating shear waves in inhomogeneous tissue equivalent phantoms and carotid artery samples using the ARF of an ultrasound transducer, and measuring the shear wave speed and its associated properties in the different layers with OCT phase maps. This method lays the foundation for future in-vitro and in-vivo studies of mechanical property measurements of biological tissues such as vascular tissues, where normal and pathological structures may exhibit significant contrast in the shear modulus.
Collapse
Affiliation(s)
- Marjan Razani
- Department of Physics, Ryerson University, Toronto, Canada
| | - Timothy W.H. Luk
- Department of Electrical and Computer Engineering, Ryerson University, Toronto, Canada
| | - Adrian Mariampillai
- Department of Electrical and Computer Engineering, Ryerson University, Toronto, Canada
| | - Peter Siegler
- Department of Electrical and Computer Engineering, Ryerson University, Toronto, Canada
| | - Tim-Rasmus Kiehl
- Department of Pathology, University Health Network, Toronto, Ontario Canada
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Ontario, Canada
| | | | - Victor X.D. Yang
- Department of Physics, Ryerson University, Toronto, Canada
- Department of Electrical and Computer Engineering, Ryerson University, Toronto, Canada
- Division of Neurosurgery, University of Toronto, Toronto, Canada
| |
Collapse
|
44
|
Mercure E, Destrempes F, Roy Cardinal MH, Porée J, Soulez G, Ohayon J, Cloutier G. A local angle compensation method based on kinematics constraints for non-invasive vascular axial strain computations on human carotid arteries. Comput Med Imaging Graph 2014; 38:123-36. [DOI: 10.1016/j.compmedimag.2013.08.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2012] [Revised: 06/28/2013] [Accepted: 08/07/2013] [Indexed: 11/16/2022]
|
45
|
Wan J, He F, Zhao Y, Zhang H, Zhou X, Wan M. Non-invasive vascular radial/circumferential strain imaging and wall shear rate estimation using video images of diagnostic ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:622-636. [PMID: 24361217 DOI: 10.1016/j.ultrasmedbio.2013.10.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2013] [Revised: 09/28/2013] [Accepted: 10/13/2013] [Indexed: 06/03/2023]
Abstract
The aim of this work was to develop a convenient method for radial/circumferential strain imaging and shear rate estimation that could be used as a supplement to the current routine screening for carotid atherosclerosis using video images of diagnostic ultrasound. A reflection model-based correction for gray-scale non-uniform distribution was applied to B-mode video images before strain estimation to improve the accuracy of radial/circumferential strain imaging when applied to vessel transverse cross sections. The incremental and cumulative radial/circumferential strain images can then be calculated based on the displacement field between consecutive B-mode images. Finally, the transverse Doppler spectra acquired at different depths along the vessel diameter were used to construct the spatially matched instantaneous wall shear values in a cardiac cycle. Vessel phantom simulation results revealed that the signal-to-noise ratio and contrast-to-noise ratio of the radial and circumferential strain images were increased by 2.8 and 5.9 dB and by 2.3 and 4.4 dB, respectively, after non-uniform correction. Preliminary results for 17 patients indicated that the accuracy of radial/circumferential strain images was improved in the lateral direction after non-uniform correction. The peak-to-peak value of incremental strain and the maximum cumulative strain for calcified plaques are evidently lower than those for other plaque types, and the echolucent plaques had higher values, on average, than the mixed plaques. Moreover, low oscillating wall shear rate values, found near the plaque and stenosis regions, are closely related to plaque formation. In conclusion, the method described can provide additional valuable results as a supplement to the current routine ultrasound examination for carotid atherosclerosis and, therefore, has significant potential as a feasible screening method for atherosclerosis diagnosis in the future.
Collapse
Affiliation(s)
- Jinjin Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China
| | - Fangli He
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China
| | - Yongfeng Zhao
- Department of Ultrasound, Xijing Hospital, Fourth Military Medical University, Xi'an, China
| | - Hongmei Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China
| | - Xiaodong Zhou
- Department of Ultrasound, Xijing Hospital, Fourth Military Medical University, Xi'an, China
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China.
| |
Collapse
|
46
|
Holzapfel GA, Mulvihill JJ, Cunnane EM, Walsh MT. Computational approaches for analyzing the mechanics of atherosclerotic plaques: a review. J Biomech 2014; 47:859-69. [PMID: 24491496 DOI: 10.1016/j.jbiomech.2014.01.011] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/13/2014] [Indexed: 11/18/2022]
Abstract
Vulnerable and stable atherosclerotic plaques are heterogeneous living materials with peculiar mechanical behaviors depending on geometry, composition, loading and boundary conditions. Computational approaches have the potential to characterize the three-dimensional stress/strain distributions in patient-specific diseased arteries of different types and sclerotic morphologies and to estimate the risk of plaque rupture which is the main trigger of acute cardiovascular events. This review article attempts to summarize a few finite element (FE) studies for different vessel types, and how these studies were performed focusing on the used stress measure, inclusion of residual stress, used imaging modality and material model. In addition to histology the most used imaging modalities are described, the most common nonlinear material models and the limited number of models for plaque rupture used for such studies are provided in more detail. A critical discussion on stress measures and threshold stress values for plaque rupture used within the FE studies emphasizes the need to develop a more location and tissue-specific threshold value, and a more appropriate failure criterion. With this addition future FE studies should also consider more advanced strain-energy functions which then fit better to location and tissue-specific experimental data.
Collapse
Affiliation(s)
- Gerhard A Holzapfel
- Graz University of Technology, Institute of Biomechanics, Kronesgasse 5-I, 8010 Graz, Austria.
| | - John J Mulvihill
- Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering and the Materials and Surface Science Institute, University of Limerick, Ireland
| | - Eoghan M Cunnane
- Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering and the Materials and Surface Science Institute, University of Limerick, Ireland
| | - Michael T Walsh
- Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering and the Materials and Surface Science Institute, University of Limerick, Ireland
| |
Collapse
|
47
|
Walsh MT, Cunnane EM, Mulvihill JJ, Akyildiz AC, Gijsen FJH, Holzapfel GA. Uniaxial tensile testing approaches for characterisation of atherosclerotic plaques. J Biomech 2014; 47:793-804. [PMID: 24508324 DOI: 10.1016/j.jbiomech.2014.01.017] [Citation(s) in RCA: 81] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/13/2014] [Indexed: 01/19/2023]
Abstract
The pathological changes associated with the development of atherosclerotic plaques within arterial vessels result in significant alterations to the mechanical properties of the diseased arterial wall. There are several methods available to characterise the mechanical behaviour of atherosclerotic plaque tissue, and it is the aim of this paper to review the use of uniaxial mechanical testing. In the case of atherosclerotic plaques, there are nine studies that employ uniaxial testing to characterise mechanical behaviour. A primary concern regarding this limited cohort of published studies is the wide range of testing techniques that are employed. These differing techniques have resulted in a large variance in the reported data making comparison of the mechanical behaviour of plaques from different vasculatures, and even the same vasculature, difficult and sometimes impossible. In order to address this issue, this paper proposes a more standardised protocol for uniaxial testing of diseased arterial tissue that allows for better comparisons and firmer conclusions to be drawn between studies. To develop such a protocol, this paper reviews the acquisition and storage of the tissue, the testing approaches, the post-processing techniques and the stress-strain measures employed by each of the nine studies. Future trends are also outlined to establish the role that uniaxial testing can play in the future of arterial plaque mechanical characterisation.
Collapse
Affiliation(s)
- M T Walsh
- Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering and the Materials and Surface Science Institute University of Limerick, Limerick, Ireland.
| | - E M Cunnane
- Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering and the Materials and Surface Science Institute University of Limerick, Limerick, Ireland
| | - J J Mulvihill
- Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering and the Materials and Surface Science Institute University of Limerick, Limerick, Ireland
| | - A C Akyildiz
- Department of Biomedical Engineering, Thoraxcenter, Erasmus Medical Centre, Rotterdam, The Netherlands
| | - F J H Gijsen
- Department of Biomedical Engineering, Thoraxcenter, Erasmus Medical Centre, Rotterdam, The Netherlands
| | - G A Holzapfel
- Graz University of Technology, Center of Biomedical Engineering Institute of Biomechanics, Kronesgasse 5-I, 8010 Graz, Austria; Royal Institute of Technology (KTH), Department of Solid Mechanics School of Engineering Sciences, Teknikringen 8d, 100 44 Stockholm, Sweden
| |
Collapse
|
48
|
Teng Z, Sadat U, Brown AJ, Gillard JH. Plaque hemorrhage in carotid artery disease: pathogenesis, clinical and biomechanical considerations. J Biomech 2014; 47:847-58. [PMID: 24485514 PMCID: PMC3994507 DOI: 10.1016/j.jbiomech.2014.01.013] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/13/2014] [Indexed: 12/21/2022]
Abstract
Stroke remains the most prevalent disabling illness today, with internal carotid artery luminal stenosis due to atheroma formation responsible for the majority of ischemic cerebrovascular events. Severity of luminal stenosis continues to dictate both patient risk stratification and the likelihood of surgical intervention. But there is growing evidence to suggest that plaque morphology may help improve pre-existing risk stratification criteria. Plaque components such a fibrous tissue, lipid rich necrotic core and calcium have been well investigated but plaque hemorrhage (PH) has been somewhat overlooked. In this review we discuss the pathogenesis of PH, its role in dictating plaque vulnerability, PH imaging techniques, marterial properties of atherosclerotic tissues, in particular, those obtained based on in vivo measurements and effect of PH in modulating local biomechanics.
Collapse
Affiliation(s)
- Zhongzhao Teng
- University Department of Radiology, University of Cambridge, UK; Department of Engineering, University of Cambridge, UK.
| | - Umar Sadat
- Department of Surgery, Cambridge University Hospitals NHS Foundation Trust, UK
| | - Adam J Brown
- Department of Cardiovascular Medicine, University of Cambridge, UK
| | | |
Collapse
|
49
|
Wang X, Jackson DC, Varghese T, Mitchell CC, Hermann BP, Kliewer MA, Dempsey RJ. Correlation of cognitive function with ultrasound strain indices in carotid plaque. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:78-89. [PMID: 24120415 PMCID: PMC3849143 DOI: 10.1016/j.ultrasmedbio.2013.08.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2013] [Revised: 07/10/2013] [Accepted: 08/01/2013] [Indexed: 05/03/2023]
Abstract
Instability in carotid vulnerable plaque can generate cerebral micro-emboli, which may be related to both stroke and eventual cognitive abnormality. Strain imaging to detect plaque vulnerability based on regions with large strain fluctuations, with arterial pulsation, may be able to determine the risk of cognitive impairment. Plaque instability may be characterized by increased strain variations over a cardiac cycle. Radiofrequency signals for ultrasound strain imaging were acquired from the carotid arteries of 24 human patients using a Siemens Antares with a VFX 13-5 linear array transducer. These patients underwent standardized cognitive assessment (Repeatable Battery for the Assessment of Neuropsychological Status [RBANS]). Plaque regions were segmented by a radiologist at end-diastole using the Medical Imaging Interaction Toolkit. A hierarchical block-matching motion tracking algorithm was used to estimate the cumulated axial, lateral and shear strains within the imaging plane. The maximum, minimum and peak-to-peak strain indices in the plaque computed from the mean cumulated strain over a small region of interest in the plaque with large deformations were obtained. The maximum and peak-to-peak mean cumulated strain indices over the entire plaque region were also computed. All strain indices were then correlated with RBANS Total performance. Overall cognitive performance (RBANS Total) was negatively associated with values of the maximum strain and the peak-to-peak for axial and lateral strains, respectively. There was no significant correlation between the RBANS Total score and shear strain and strain indices averaged over the entire identified plaque for this group of patients. However, correlation of maximum lateral strain was higher for symptomatic patients (r = -0.650, p = 0.006) than for asymptomatic patients (r = -0.115, p = 0.803). On the other hand, correlation of maximum axial strain averaged over the entire plaque region was significantly higher for asymptomatic patients (r = -0.817, p = 0.016) than for symptomatic patients (r = -0.224, p = 0.402). The results reveal a direct relationship between the maximum axial and lateral strain indices in carotid plaque and cognitive impairment.
Collapse
Affiliation(s)
- Xiao Wang
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | | | | | | | | | | | | |
Collapse
|
50
|
Doyley MM, Parker KJ. Elastography: general principles and clincial applications. ACTA ACUST UNITED AC 2014; 9:1-11. [PMID: 24459461 DOI: 10.1016/j.cult.2013.09.006] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Affiliation(s)
- M M Doyley
- University of Rochester, Department of Electrical and Computer Engineering, Hopeman, Engineering Building 343, Box 270126, Rochester, NY 14627, USA
| | - K J Parker
- University of Rochester, Department of Electrical and Computer Engineering, Hopeman, Engineering Building 343, Box 270126, Rochester, NY 14627, USA
| |
Collapse
|