1
|
Chu G, Niu H. Knowledge mapping and global trends in the field of low-intensity pulsed ultrasound and endocrine and metabolic diseases: a bibliometric and visual analysis from 2012 to 2022. Front Endocrinol (Lausanne) 2023; 14:1237864. [PMID: 37732128 PMCID: PMC10508976 DOI: 10.3389/fendo.2023.1237864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Accepted: 08/21/2023] [Indexed: 09/22/2023] Open
Abstract
Background Low-intensity pulsed ultrasound (LIPUS) is a highly promising therapeutic method that has been widely used in rehabilitation, orthopedics, dentistry, urology, gynecology, and other multidisciplinary disease diagnoses and treatments. It has attracted extensive attention worldwide. However, there is currently a lack of comprehensive and systematic research on the current status and future development direction of the LIPUS field. Therefore, this study comprehensively analyzed LIPUS-related reports from the past decade using bibliometrics methods, and further conducted research specifically focusing on its application in endocrine and metabolic diseases. Methods We downloaded LIPUS literature from 2012 to 2022 reported in the Web of Science Core Collection Science Citation Index-Expanded and Social Sciences Citation Index, and used bibliometric analysis software such as VOSviewer and CiteSpace to execute the analysis and visualize the results. Results We searched for 655 English articles published on LIPUS from 2012 to 2022. China had the highest number of published articles and collaborations between China and the United States were the closest in this field. Chongqing Medical University was the institution with the highest output, and ULTRASOUND IN MEDICINE AND BIOLOGY was the journal with the most related publications. In recent years, research on the molecular mechanisms of LIPUS has continued to deepen, and its clinical applications have also continued to expand. The application of LIPUS in major diseases such as oxidative stress, regeneration mechanism, and cancer is considered to be a future research direction, especially in the field of endocrinology and metabolism, where it has broad application value. Conclusion Global research on LIPUS is expected to continue to increase, and future research will focus on its mechanisms of action and clinical applications. This study comprehensively summarizes the current development status and global trends in the field of LIPUS, and its research progress in the field of endocrine and metabolic diseases, providing valuable reference for future research in this field.
Collapse
Affiliation(s)
| | - Haitao Niu
- Department of Urology, The Affiliated Hospital of Qingdao University, Qingdao, China
| |
Collapse
|
2
|
Pereira LF, Fontes-Pereira AJ, de Albuquerque Pereira WC. Influence of Low-Intensity Pulsed Ultrasound Parameters on the Bone Mineral Density in Rat Model: A Systematic Review. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1687-1698. [PMID: 37121881 DOI: 10.1016/j.ultrasmedbio.2023.03.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 02/23/2023] [Accepted: 03/03/2023] [Indexed: 06/19/2023]
Abstract
OBJECTIVE Bone recovery typically depends on the age of organisms or the prevalence of metabolic disorders such as osteoporosis, which is a metabolic condition characterized by decreased bone strength and bone mineral density (BMD). Therefore, low-intensity pulsed ultrasound (LIPUS), a non-invasive method for osteogenic stimulation, presents promising results. However, heterogeneity in animal study designs is a typical characteristic. Hence, we conducted a systematic review to evaluate the effectiveness of LIPUS in the recovery of experimental bone defects using rat models. We examined the areal and volumetric BMD to identify LIPUS doses to be applied and evaluated the accuracy reported by previous studies. METHODS The Virtual Health Library regional portal, PubMed, Embase, EBSCOhost, Scopus and CAPES were reviewed for animal studies that compared fracture treatments based on LIPUS with sham or no treatments using rat models and reported BMD as an outcome. The tool provided by the Systematic Review Centre for Laboratory Animal Experimentation (SYRCLE) and the Collaborative Approach to Meta-Analysis and Review of Animal Data from Experimental Studies (CAMARADES) checklist were used to assess the bias and quality of such studies. RESULTS Of the six studies reviewed, the most frequently used LIPUS dose had an ultrasonic frequency of 1.0 MHz, repetition rate of 0.1 kHz and pulse duration of 2000 μs. An intensity (ISATA) of 30 mW/cm2 was the most preferred for bone recovery. However, the BMD could not solely irrefutably evaluate the effectiveness of LIPUS in bone recovery as the results were discordant with each other. The discrepancies in experimental methodologies, low-quality classifications and high risk of bias in the selected studies, however, did not validate the undertaking of a meta-analysis. CONCLUSION On the basis of the BMD results, no sufficient evidence was found to recommend the use of LIPUS for bone recovery in rat models. Thus, this systematic review indicates that the accuracy of such reports must be improved to improve their scientific quality to facilitate a transition of LIPUS applications from pre-clinical research to clinic use.
Collapse
Affiliation(s)
- Luiz Fernando Pereira
- Biomedical Engineering Program/COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
| | - Aldo José Fontes-Pereira
- Biomedical Engineering Program/COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil; Centro Universitário Serra dos Órgãos-Unifeso, Teresópolis, Rio de Janeiro, Brazil
| | | |
Collapse
|
3
|
Tang L, Wu T, Zhou Y, Zhong Y, Sun L, Guo J, Fan X, Ta D. Study on synergistic effects of carboxymethyl cellulose and LIPUS for bone tissue engineering. Carbohydr Polym 2022; 286:119278. [DOI: 10.1016/j.carbpol.2022.119278] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 01/28/2022] [Accepted: 02/18/2022] [Indexed: 02/07/2023]
|
4
|
Calabrese EJ. Hormesis and adult adipose-derived stem cells. Pharmacol Res 2021; 172:105803. [PMID: 34364988 DOI: 10.1016/j.phrs.2021.105803] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 08/03/2021] [Accepted: 08/03/2021] [Indexed: 02/06/2023]
Abstract
This paper provides a detailed assessment of the occurrence of hormetic dose responses in adipose-derived stem cells (ADSCs) of animal models and humans. While a broad range of endpoints has been considered, the predominant research focus in the literature has involved cell proliferation and differentiation. Hormetic dose responses have been commonly reported for ADSCs, encompassing a broad range of chemicals, including pharmaceuticals, dietary supplements and endogenous agents as well as a broad range of physical stressors such as low frequency vibrations, electromagnetic frequency (EMF), heat and sound waves. Numerous agents upregulate key functions such as cell proliferation and differentiation in ADSCs, following the quantitative features of the hormesis dose response model. The paper also assesses the capacity of agents to selectively and dose-dependently activate cell proliferation and/or differentiation, their underlying mechanistic foundations and potential clinical implications. These findings indicate that hormetic dose responses are a prominent feature of ADSC biology and may have a determinant role in their potential clinical applications.
Collapse
Affiliation(s)
- Edward J Calabrese
- Toxicology, Environmental Health Sciences, School of Public Health and Health Sciences, Morrill I, N344, University of Massachusetts, Amherst, MA 01003, USA.
| |
Collapse
|
5
|
Sun S, Tang L, Zhao T, Kang Y, Sun L, Liu C, Li Y, Xu F, Qin YX, Ta D. Longitudinal effects of low-intensity pulsed ultrasound on osteoporosis and osteoporotic bone defect in ovariectomized rats. ULTRASONICS 2021; 113:106360. [PMID: 33561635 DOI: 10.1016/j.ultras.2021.106360] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2020] [Revised: 01/11/2021] [Accepted: 01/13/2021] [Indexed: 06/12/2023]
Abstract
Low-intensity pulsed ultrasound (LIPUS) with an intensity (spatial average temporal average, ISATA) of 30 mW/cm2 has been widely proved to be effective on impaired bone healing, but showing little effectiveness in the treatment of osteoporosis. We hypothesized that the intensity of LIPUS may be a key factor in explaining this difference, thus two intensity levels, the widely used 30 mW/cm2 and a higher 150 mW/cm2, were used to simultaneously treat osteoporosis and osteoporotic bone defect in ovariectomized (OVX) rats with a 1-mm drill hole on their left femurs.Results showed that 150 mW/cm2 LIPUS augmented the healing rate of the drill hole than 30 mW/cm2 after 3-week LIPUS treatment, although did not further enhance the healing rate after 6-week LIPUS treatment. For ameliorating osteoporosis, 150 mW/cm2 LIPUS achieved more advantages over 30 mW/cm2 in improving bone density, microstructure and biomechanics 6 weeks after LIPUS intervention. In conclusion, LIPUS with an intensity of 30 mW/cm2 was sufficient to facilitate bone defect healing, but a higher intensity can be considered as a rapid trigger for osteoporotic bone repair. In addition, improving the intensity of LIPUS may be a potentially effective consideration for alleviation of osteoporosis, and the LIPUS regimen in the treatment of osteoporosis remains to be optimized.
Collapse
Affiliation(s)
- Shuxin Sun
- Department of Electronic Engineering, Fudan University, Shanghai 200433, China
| | - Liang Tang
- Institute of Sports Biology, Shaanxi Normal University, Xi'an 710119, China
| | - Tingting Zhao
- Institute of Sports Biology, Shaanxi Normal University, Xi'an 710119, China
| | - Yiting Kang
- Institute of Sports Biology, Shaanxi Normal University, Xi'an 710119, China
| | - Lijun Sun
- Institute of Sports Biology, Shaanxi Normal University, Xi'an 710119, China
| | - Chengcheng Liu
- Academy for Engineering and Technology, Fudan University, Shanghai 200433, China
| | - Ying Li
- Department of Electronic Engineering, Fudan University, Shanghai 200433, China
| | - Feng Xu
- Department of Electronic Engineering, Fudan University, Shanghai 200433, China
| | - Yi-Xian Qin
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-5281, United States
| | - Dean Ta
- Department of Electronic Engineering, Fudan University, Shanghai 200433, China; Academy for Engineering and Technology, Fudan University, Shanghai 200433, China.
| |
Collapse
|
6
|
de Lucas B, Pérez LM, Bernal A, Gálvez BG. Application of low-intensity pulsed therapeutic ultrasound on mesenchymal precursors does not affect their cell properties. PLoS One 2021; 16:e0246261. [PMID: 33571276 PMCID: PMC7877602 DOI: 10.1371/journal.pone.0246261] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Accepted: 01/15/2021] [Indexed: 12/13/2022] Open
Abstract
Ultrasound is considered a safe and non-invasive tool in regenerative medicine and has been used in the clinic for more than twenty years for applications in bone healing after the approval of the Exogen device, also known as low-intensity pulsed ultrasound (LIPUS). Beyond its effects on bone health, LIPUS has also been investigated for wound healing of soft tissues, with positive results for various cell processes including cell proliferation, migration and angiogenesis. As LIPUS has the potential to treat chronic skin wounds, we sought to evaluate the effects produced by a conventional therapeutic ultrasound device at low intensities (also considered LIPUS) on the migration capacity of mouse and human skin mesenchymal precursors (s-MPs). Cells were stimulated for 3 days (20 minutes per day) using a traditional ultrasound device with the following parameters: 100 mW/cm2 with 20% duty cycle and frequency of 3 MHz. At the parameters used, ultrasound failed to affect s-MP proliferation, with no evident changes in morphology or cell groupings, and no changes at the cytoskeletal level. Further, the migration and invasion ability of s-MPs were unaffected by the ultrasound protocol, and no major changes were detected in the gene/protein expression of ROCK1, integrin β1, laminin β1, type I collagen and transforming growth factor β1. Finally, RNA-seq analysis revealed that only 10 genes were differentially expressed after ultrasound stimulation. Among them, 5 encode for small nuclear RNAs and 2 encode for proteins belonging to the nuclear pore complex. Considering the results overall, while the viability of s-MPs was not affected by ultrasound stimulation and no changes were detected in proliferation/migration, RNA-seq analysis would suggest that s-MPs do respond to ultrasound. The use of 100 mW/cm2 intensity or conventional therapeutic ultrasound devices might not be optimal for the stimulation the properties of cell populations. Future studies should investigate the potential application of ultrasound using variations of the tested parameters.
Collapse
Affiliation(s)
- Beatriz de Lucas
- Faculty of Biomedical and Health Sciences, Universidad Europea de Madrid, Madrid, Spain
| | - Laura M. Pérez
- Faculty of Biomedical and Health Sciences, Universidad Europea de Madrid, Madrid, Spain
| | - Aurora Bernal
- Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid, Spain
| | - Beatriz G. Gálvez
- Faculty of Biomedical and Health Sciences, Universidad Europea de Madrid, Madrid, Spain
| |
Collapse
|
7
|
Tang L, An S, Zhang Z, Fan X, Guo J, Sun L, Ta D. MSTN is a key mediator for low-intensity pulsed ultrasound preventing bone loss in hindlimb-suspended rats. Bone 2021; 143:115610. [PMID: 32829040 DOI: 10.1016/j.bone.2020.115610] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Revised: 08/17/2020] [Accepted: 08/18/2020] [Indexed: 12/13/2022]
Abstract
Low-intensity pulsed ultrasound (LIPUS) has been used to accelerate bone fracture healing. However, the issue whether LIPUS is effective in preventing osteoporosis has not been clarified, and if so, what possible mechanisms might be responsible. Myostatin (MSTN) is a negative regulator of muscle growth, and its absence will trigger a positive response to bone. In this study, we examined the effects of LIPUS on bone micro-structure, mechanical properties and damage healing of hindlimb-suspended rats, and investigated whether the inhibition of MSTN plays a role in this process. The rats were randomly divided into four groups: Normal control group (NC), Hind limb suspension group (HLS), Hind limb suspension and 80 mW/cm2 LIPUS irradiation group (HLS+ 80 mW/cm2), Hind limb suspension and 30 mW/cm2 LIPUS irradiation group (HLS+ 30 mW/cm2). The HLS+ 80 mW/cm2 rats were treated with LIPUS (1 MHz, 80 mW/cm2) and the HLS+ 30 mW/cm2 rats were treated with LIPUS (1 MHz, 30 mW/cm2) on the femur for 20 min/day for 28 days. MC3T3-E1 cells were respectively cultured with the serum of wild type mouse and MSTN knockout mouse at 1% concentration for 7 days. After 28 days, LIPUS effectively prevented the destruction of bone microstructure and the decline of mechanical properties, and promoted bone defect healing in the tail-suspended rats. In addition, LIPUS effectively reduced the MSTN content in the quadriceps and serum of the tail-suspended rats, inhibited its receptor and downstream signaling molecules and activated the Wnt signaling pathway in femurs. Growth of MC-3T3-E1 cell cultured with the serum of MSTN knockout mice was superior to that with wild mice serum on day 7. These results indicate that MSTN is a key mediator in LIPUS preventing bone loss caused by hindlimb-suspension.
Collapse
Affiliation(s)
- Liang Tang
- Institute of Sports Biology, Shaanxi Normal University, Xi'an 710119, China
| | - Shasha An
- Institute of Sports Biology, Shaanxi Normal University, Xi'an 710119, China
| | - Zhihao Zhang
- Institute of Sports Biology, Shaanxi Normal University, Xi'an 710119, China
| | - Xiushan Fan
- Institute of Sports Biology, Shaanxi Normal University, Xi'an 710119, China
| | - Jianzhong Guo
- Shaanxi Key Laboratory of Ultrasonics, Shaanxi Normal University, Xi'an 710119, China
| | - Lijun Sun
- Institute of Sports Biology, Shaanxi Normal University, Xi'an 710119, China.
| | - Dean Ta
- Department of Electronic Engineering, Fudan University, Shanghai 200433, China; Human Phenome Institute, Fudan University, Shanghai 201203, China; Key Laboratory of Medical Imaging Computing and Computer Assisted Intervention (MICCAI) of Shanghai, Shanghai 200032, China.
| |
Collapse
|
8
|
Liu X, Hu Y, Wu L, Li S. Effects of collimated and focused low-intensity pulsed ultrasound stimulation on the mandible repair in rabbits. ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:98. [PMID: 32175391 DOI: 10.21037/atm.2019.12.89] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Background This study was to evaluate the effects of low-intensity collimated pulse ultrasound (LICU) and low-intensity focused-pulse ultrasound (LIFU) stimulation on the osteogenesis in the porous silicon carbide (SiC) scaffold implanted in the rabbit mandible. Methods Rabbits were randomly divided into LIFU group, LICU group and control group (without ultrasound treatment). The intensities of LICU and LIFU were 30 and 300 mW/cm2, respectively. The subcutaneous and subperiosteal temperatures were measured continuously during the 20-min ultrasound treatment. Then, the porous SiC scaffolds were implanted into the mandible, followed by LICU or LIFU once daily, and the quantity and structure of bone were assessed by methylene blue-acid fuchsin staining and micro-CT at 3, 6 and 9 weeks after implantation. Results The changes in the subcutaneous and subperiosteal temperatures during LICU and LIFU were less than 1 °C. The bone mass increased and the structure of bone tissues became more mature over time. The bone mass and mean pore occupancy fraction (POF) in the LIFU group were significantly greater than in the LICU group at three time points (P<0.05). Bone ingrowth in different directions was observed, and the new bone formation in the mesial, distal, top, and lingual sides of the implants in the LIFU group was greater than in the LICU group and control group (P<0.05). Conclusions LIFU and LICU may effectively promote bone formation in the mandible scaffold, and LIFU significantly accelerates bone formation in both buccal side and lingual side of the scaffold.
Collapse
Affiliation(s)
- Xiaohan Liu
- Department of Prosthodontics, School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang 110002, China
| | - Ying Hu
- Department of Pediatric Dentistry, Dalian Stomatological Hospital, Dalian 116021, China
| | - Lin Wu
- Department of Prosthodontics, School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang 110002, China
| | - Shujun Li
- Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
| |
Collapse
|
9
|
Sun S, Sun L, Kang Y, Tang L, Qin YX, Ta D. Therapeutic Effects of Low-Intensity Pulsed Ultrasound on Osteoporosis in Ovariectomized Rats: Intensity-Dependent Study. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:108-121. [PMID: 31587953 DOI: 10.1016/j.ultrasmedbio.2019.08.025] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2019] [Revised: 08/13/2019] [Accepted: 08/30/2019] [Indexed: 06/10/2023]
Abstract
This study investigated the effects of low-intensity pulsed ultrasound (LIPUS) of different spatial-average-temporal-average intensity (ISATA) ranging from 15-150 mW/cm2 on the treatment of osteoporosis in ovariectomized rats. Healthy 3-mo-old female Sprague-Dawley rats were randomly divided into nine groups (n = 12 per group): sham-ovariectomy (OVX) control group, OVX control group and OVX groups treated with LIPUS at seven different intensities (ISATA: 15, 30, 50, 75, 100, 125 and 150 mW/cm2, respectively). LIPUS was applied to bilateral femurs 12 wk post-OVX for 20 min/d for 6 wk. Micro-computed tomography, biomechanical tests, serum biochemical analysis and grip strength tests were performed to evaluate the therapeutic effects of LIPUS at different intensities. Results revealed that LIPUS intensity yielded strong correlations with bone mineral density and bone microstructure (R2 = 0.57-0.83) and bone mechanical strength (R2 = 0.80-0.97), and that the intensity of 150 mW/cm2, instead of the 30 mW/cm2 widely used in bone fracture healing, was most effective in maintaining bone mass among all the LIPUS signals between 15 and 150 mW/cm2. This suggests that higher ultrasound intensity (i.e., 150 mW/cm2) may be more effective than lower intensity in mitigation of osteopenia and osteoporosis.
Collapse
Affiliation(s)
- Shuxin Sun
- Department of Electronic Engineering, Fudan University, Shanghai, China
| | - Lijun Sun
- Institute of Sports Biology, Shaanxi Normal University, Xi'an, China
| | - Yiting Kang
- Institute of Sports Biology, Shaanxi Normal University, Xi'an, China
| | - Liang Tang
- Institute of Sports Biology, Shaanxi Normal University, Xi'an, China
| | - Yi-Xian Qin
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, USA
| | - Dean Ta
- Department of Electronic Engineering, Fudan University, Shanghai, China; State Key Laboratory of ASIC and System, Fudan University, Shanghai, China; Key Laboratory of Medical Imaging Computing and Computer Assisted Intervention (MICCAI) of Shanghai, Shanghai, China.
| |
Collapse
|
10
|
Maurya RK, Jayan B, Singh H, Nakra O, Sharma P. Effects of Low-Intensity Pulsed Ultrasound Therapy on the Temporomandibular Joint Complex in Conjunction With a Fixed Functional Appliance: A Prospective 3-Dimensional Cone Beam Computed Tomographic Study. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2019; 38:1661-1676. [PMID: 30393868 DOI: 10.1002/jum.14850] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2018] [Revised: 09/07/2018] [Accepted: 09/28/2018] [Indexed: 06/08/2023]
Abstract
OBJECTIVES This prospective study aimed to analyze 3-dimensional changes in the temporomandibular joint (TMJ) complex with a synergistic effect of functional jaw orthopedics using a fixed functional appliance and low-intensity pulsed ultrasound (LIPUS) therapy. METHODS Forty patients with skeletal class II malocclusion were randomly assigned to 4 groups (2 control groups and 2 test groups) of 10 patients each. After insertion of the fixed functional appliance, the test group was stimulated with LIPUS therapy in the TMJ region bilaterally for 20 minutes daily for first 10 days and thereafter at least 3 times per week until complete mandibular advancement was achieved. Three-dimensional images obtained with a cone beam computed tomographic scanner were used to analyze the changes in the TMJ complex at the prefunctional stage and after completion of functional appliance therapy. Direct intragroup and intergroup comparisons for different morphometric variables were conducted with the Student t test. RESULTS The 40 patients included 20 male and 20 female patients between the ages of 12 and 16 years (mean age ± SD, 13.2 ± 1.8 years). Both the test groups and the control groups showed statistically significant variable changes in condylar head position and morphometric changes in relation to the joint space analysis (mean differences, -1.000 and -1.080 mm; P < .05). However, no significant differences were found during the intergroup comparisons at the prefunctional and postfunctional stages for the variables examined, except for the measurements of the linear distance of the condyle to the external auditory meatus on both the right and left sides at the prefunctional phase. CONCLUSIONS Low-intensity pulsed ultrasound therapy positively affects the quantum of the joint space, thus proving to be a promising adjunct in enhancing treatment outcomes of functional jaw orthopedics in growing patients with skeletal class II malocclusions.
Collapse
Affiliation(s)
- Raj Kumar Maurya
- Department of Orthodontics and Dentofacial Orthopedics, Army Dental Center (Research and Referral), Delhi, India
| | - Balakrishna Jayan
- Department of Orthodontics and Dentofacial Orthopedics, Army Dental Center (Research and Referral), Delhi, India
| | - Harpreet Singh
- Department of Orthodontics and Dentofacial Orthopedics, Employees' State Insurance Corporation Dental College and Hospital, Delhi, India
| | - Oonit Nakra
- Department of Orthodontics and Dentofacial Orthopedics, Army Dental Center (Research and Referral), Delhi, India
| | - Poonam Sharma
- Department of Orthodontics and Dentofacial Orthopedics, Employees' State Insurance Corporation Dental College and Hospital, Delhi, India
| |
Collapse
|
11
|
Effect of ultrasound on bone fracture healing: A computational bioregulatory model. Comput Biol Med 2018; 100:74-85. [DOI: 10.1016/j.compbiomed.2018.06.024] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2018] [Revised: 06/23/2018] [Accepted: 06/23/2018] [Indexed: 12/22/2022]
|
12
|
Bayat M, Virdi A, Jalalifirouzkouhi R, Rezaei F. Comparison of effects of LLLT and LIPUS on fracture healing in animal models and patients: A systematic review. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2018; 132:3-22. [PMID: 28688752 DOI: 10.1016/j.pbiomolbio.2017.07.004] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2017] [Revised: 06/30/2017] [Accepted: 07/04/2017] [Indexed: 12/29/2022]
Abstract
The aim of this paper is to study the in vivo potency of low-level laser therapy (LLLT) and low intensity pulsed ultrasound (LIPUS) alone, accompanied by bone grafts, or accompanied by other factors on fracture healing in animal models and patients. In this paper, we aim to systematically review the published scientific literature regarding the use of LLLT and LIPUS to accelerate fracture healing in animal models and patients. We searched the PubMed database for the terms LLLT or LIPUS and/or bone, and fracture. Our analysis also suggests that both LIPUS and LLLT may be beneficial to fracture healing in patients, and that LIPUS is more effective. These finding are of considerable importance in those treatments with a LIPUS, as a laser device may reduce healing time. The most clinically relevant impact of the LIPUS treatment could be a significant reduction in the proportion of patients who go on to develop a nonunion. If it is confirmed that the therapeutic influence is true and reliable, patients will obtain benefits from LIPUS and LLLT. Further clinical trials of high methodological quality are needed in order to determine the optimal role of LIPUS and LLLT in fracture healing in patients.
Collapse
Affiliation(s)
- Mohammad Bayat
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL, USA; Cellular and Molecular Biology Research Center, Department of Biology and Anatomical Sciences, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| | - Amarjit Virdi
- Department of Cell & Molecular Medicine, (formerly, Anatomy and Cell Biology), Rush University Medical Center, 1750 W. Harrison St., Suite 1413A, Chicago, IL 60612, USA.
| | | | - Fatemehalsadat Rezaei
- Cellular and Molecular Biology Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
13
|
Cao H, Feng L, Wu Z, Hou W, Li S, Hao Y, Wu L. Effect of low-intensity pulsed ultrasound on the biological behavior of osteoblasts on porous titanium alloy scaffolds: An in vitro and in vivo study. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 80:7-17. [PMID: 28866219 DOI: 10.1016/j.msec.2017.05.078] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Revised: 05/03/2017] [Accepted: 05/13/2017] [Indexed: 01/24/2023]
Abstract
Low-intensity pulsed ultrasound (LIPUS) has been used in patients with fresh fractures, delayed union and non-union to enhance bone healing and improve functional outcome. However, there were few studies concerning the effects of LIPUS on the biological behavior of osteoblasts on porous scaffolds. This study aimed to evaluate the effects of LIPUS on the biological behavior of osteoblasts on porous titanium-6aluminum-4vanadium (Ti6Al4V) alloy scaffolds in vitro and in vivo. Scaffolds were randomly divided into an ultrasound group and a control group. Mouse pre-osteoblast cells were cultured with porous Ti6Al4V scaffolds in vitro. The effects of LIPUS on the biological behavior of osteoblasts were evaluated by observing the adhesion, proliferation, differentiation and ingrowth depth on porous Ti6Al4V scaffolds. In addition, scaffolds were implanted into rabbit mandibular defects in vivo. The effects of LIPUS on bone regeneration were evaluated via micro-CT, fluorescent staining and toluidine blue staining. The results revealed that osteoblast adhered well to the scaffolds, and there was no significant difference in the methyl thiazolyl tetrazolium value between the ultrasound group and the control group (p>0.05). Compared with the control group, ultrasound promoted the alkaline phosphatase activity, osteocalcin levels and ingrowth depth of the cells on the scaffolds (p<0.05). In addition, micro-CT and histomorphological analysis showed that the volume and amount of new bone formation were increased and that bone maturity was improved in the ultrasound group compared to the control group. These results indicate that LIPUS promotes osteoblast differentiation as well as enhances bone ingrowth in porous Ti6Al4V scaffolds, and promotes bone formation and maturity in porous Ti6Al4V scaffolds.
Collapse
Affiliation(s)
- Hongjuan Cao
- Department of Prosthodontics, School of Stomatology, China Medical University, Shenyang, Liaoning, People's Republic of China
| | - Lifang Feng
- Department of Prosthodontics, School of Stomatology, China Medical University, Shenyang, Liaoning, People's Republic of China
| | - Zhenxian Wu
- Department of Prosthodontics, School of Stomatology, China Medical University, Shenyang, Liaoning, People's Republic of China
| | - Wentao Hou
- Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, Liaoning, People's Republic of China
| | - Shujun Li
- Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, Liaoning, People's Republic of China
| | - Yulin Hao
- Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, Liaoning, People's Republic of China
| | - Lin Wu
- Department of Prosthodontics, School of Stomatology, China Medical University, Shenyang, Liaoning, People's Republic of China.
| |
Collapse
|
14
|
Lu H, Liu F, Chen H, Chen C, Qu J, Xu D, Zhang T, Zhou J, Hu J. The effect of low-intensity pulsed ultrasound on bone-tendon junction healing: Initiating after inflammation stage. J Orthop Res 2016; 34:1697-1706. [PMID: 26833973 PMCID: PMC6084317 DOI: 10.1002/jor.23180] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2015] [Accepted: 01/21/2016] [Indexed: 02/04/2023]
Abstract
The purpose of this study was to explore the effect of low-intensity pulsed ultrasound (LIPUS) treatment initiating after inflammation stage on the process of bone-tendon junction (BTJ) healing in a rabbit model. Thirty-six rabbits undergoing partial patellectomy were randomly divided into two groups: control and LIPUS. The period of initial inflammatory stage is 2 weeks. So LIPUS treatment was initiated at postoperative week 2 and continued until the patella-patellar tendon (PPT) complexes were harvested at postoperative weeks 4, 8, and 16. At each time point, the PPT complexes were harvested for qRT-PCR, histology, radiographs, synchroton radiation micro computed tomography (SR-µCT), and biomechanical testing. The qRT-PCR results showed that LIPUS treatment beginning at postoperative week 2 played an anti-inflammatory role in BTJ healing. Histologically, the LIPUS group showed more advanced remodeling of the lamellar bone and marrow cavity than the control group. The area and length of the new bone in the LIPUS group were significantly greater than the control group at postoperative weeks 8 and 16. SR-µCT demonstrated that new bone formation and remodeling in the LIPUS group were more advanced than the control group. Biomechanical test results demonstrated that the failure load, ultimate strength and energy at failure were significantly higher than those of the control group. In conclusion, LIPUS treatment beginning at postoperative week 2 was able to accelerate bone formation during the bone-tendon junction healing process and significantly improved the healing quality of BTJ injury. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1697-1706, 2016.
Collapse
Affiliation(s)
- Hongbin Lu
- Department of Sports MedicineResearch Center of Sports MedicineXiangya HospitalCentral South UniversityChangsha410008China
| | - Feifei Liu
- Department of Sports MedicineResearch Center of Sports MedicineXiangya HospitalCentral South UniversityChangsha410008China
| | - Huabin Chen
- Department of Sports MedicineResearch Center of Sports MedicineXiangya HospitalCentral South UniversityChangsha410008China
| | - Can Chen
- Department of Sports MedicineResearch Center of Sports MedicineXiangya HospitalCentral South UniversityChangsha410008China
| | - Jin Qu
- Department of Sports MedicineResearch Center of Sports MedicineXiangya HospitalCentral South UniversityChangsha410008China
| | - Daqi Xu
- Department of Sports MedicineResearch Center of Sports MedicineXiangya HospitalCentral South UniversityChangsha410008China
| | - Tao Zhang
- Department of Sports MedicineResearch Center of Sports MedicineXiangya HospitalCentral South UniversityChangsha410008China
| | - Jingyong Zhou
- Department of Sports MedicineResearch Center of Sports MedicineXiangya HospitalCentral South UniversityChangsha410008China
| | - Jianzhong Hu
- Department of Spine SurgeryResearch Center of Sports MedicineXiangya HospitalCentral South UniversityChangsha410008China
| |
Collapse
|
15
|
Harrison A, Lin S, Pounder N, Mikuni-Takagaki Y. Mode & mechanism of low intensity pulsed ultrasound (LIPUS) in fracture repair. ULTRASONICS 2016; 70:45-52. [PMID: 27130989 DOI: 10.1016/j.ultras.2016.03.016] [Citation(s) in RCA: 116] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2015] [Revised: 03/22/2016] [Accepted: 03/28/2016] [Indexed: 06/05/2023]
Abstract
It has been 30years since the first level one clinical trial demonstrated low intensity pulsed ultrasound (LIPUS) could accelerate fracture repair. Since 1994 numerous investigations have been performed on the effect of LIPUS. The majority of these studies have used the same signal parameters comprised of an intensity of 30mW/cm(2) SATA, an ultrasound carrier frequency of 1.5MHz, pulsed at 1kHz with an exposure time of 20minutes per day. These studies show that a biological response is stimulated in the cell which produces bioactive molecules. The production of these molecules, linked with observations demonstrating the enhanced effects on mineralization by LIPUS, might be considered the general manner, or mode, of how LIPUS stimulates fractures to heal. We propose a mechanism for how the LIPUS signal can enhance fracture repair by combining the findings of numerous studies. The LIPUS signal is transmitted through tissue to the bone, where cells translate this mechanical signal to a biochemical response via integrin mechano-receptors. The cells enhance the production of cyclo-oxygenese 2 (COX-2) which in turn stimulates molecules to enhance fracture repair. The aim of this review is to present the state of the art data related to LIPUS effects and mechanism.
Collapse
Affiliation(s)
| | - Sheldon Lin
- Department of Orthopedics, Rutgers, New Jersey Medical School, USA
| | | | | |
Collapse
|
16
|
Padilla F, Puts R, Vico L, Guignandon A, Raum K. Stimulation of Bone Repair with Ultrasound. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2016; 880:385-427. [PMID: 26486349 DOI: 10.1007/978-3-319-22536-4_21] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
This chapter reviews the different options available for the use of ultrasound in the enhancement of fracture healing or in the reactivation of a failed healing process: LIPUS, shock waves and ultrasound-mediated delivery of bioactive molecules, such as growth factors or plasmids. The main emphasis is on LIPUS, or Low Intensity Pulsed Ultrasound, the most widespread and studied technique. LIPUS has pronounced bioeffects on tissue regeneration, while employing intensities within a diagnostic range. The biological response to LIPUS is complex as the response of numerous cell types to this stimulus involves several pathways. Known to-date mechanotransduction pathways involved in cell responses include MAPK and other kinases signaling pathways, gap-junctional intercellular communication, up-regulation and clustering of integrins, involvement of the COX-2/PGE2 and iNOS/NO pathways, and activation of the ATI mechanoreceptor. Mechanisms at the origin of LIPUS biological effects remain intriguing, and analysis is hampered by the diversity of experimental systems used in-vitro. Data point to clear evidence that bioeffects can be modulated by direct and indirect mechanical effects, like acoustic radiation force, acoustic streaming, propagation of surface waves, heat, fluid-flow induced circulation and redistribution of nutrients, oxygen and signaling molecules. One of the future engineering challenge is therefore the design of dedicated experimental set-ups allowing control of these different mechanical phenomena, and to relate them to biological responses. Then, the derivation of an 'acoustic dose' and the cross-calibration of the different experimental systems will be possible. Despite this imperfect knowledge of LIPUS biophysics, the clinical evidence, although most often of low quality, speaks in favor of the clinical use of LIPUS, when the economics of nonunion and the absence of toxicity of this ultrasound technology are taken into account.
Collapse
Affiliation(s)
| | - Regina Puts
- Berlin-Brandenburg School for Regenerative Therapies, Charité - Universitätsmedizin Berlin, Föhrerstr. 15, 13353, Berlin, Germany
| | - Laurence Vico
- Inserm U1059 Lab Biologie intégrée du Tissu Osseux, Université de Saint-Etienne, St-Etienne, 42023, France
| | - Alain Guignandon
- Inserm U1059 Lab Biologie intégrée du Tissu Osseux, Université de Saint-Etienne, St-Etienne, 42023, France
| | - Kay Raum
- Berlin-Brandenburg School for Regenerative Therapies, Charité - Universitätsmedizin Berlin, Föhrerstr. 15, 13353, Berlin, Germany
| |
Collapse
|
17
|
Bronoosh P, Tanideh N, Noorafshan A, Andisheh Tadbir A, Aalipanah M, Kamali F, Abbasnia K, Koohi-Hosseinabadi O. Effects of low-intensity pulsed ultrasound on healing of mandibular bone defects: an experimental study in rabbits. Int J Oral Maxillofac Surg 2015; 44:277-84. [DOI: 10.1016/j.ijom.2014.09.020] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2014] [Revised: 07/06/2014] [Accepted: 09/17/2014] [Indexed: 11/26/2022]
|
18
|
Wei FY, Leung KS, Li G, Qin J, Chow SKH, Huang S, Sun MH, Qin L, Cheung WH. Low intensity pulsed ultrasound enhanced mesenchymal stem cell recruitment through stromal derived factor-1 signaling in fracture healing. PLoS One 2014; 9:e106722. [PMID: 25181476 PMCID: PMC4152330 DOI: 10.1371/journal.pone.0106722] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2014] [Accepted: 08/02/2014] [Indexed: 01/01/2023] Open
Abstract
Low intensity pulsed ultrasound (LIPUS) has been proven effective in promoting fracture healing but the underlying mechanisms are not fully depicted. We examined the effect of LIPUS on the recruitment of mesenchymal stem cells (MSCs) and the pivotal role of stromal cell-derived factor-1/C-X-C chemokine receptor type 4 (SDF-1/CXCR4) pathway in response to LIPUS stimulation, which are essential factors in bone fracture healing. For in vitro study, isolated rat MSCs were divided into control or LIPUS group. LIPUS treatment was given 20 minutes/day at 37 °C for 3 days. Control group received sham LIPUS treatment. After treatment, intracellular CXCR4 mRNA, SDF-1 mRNA and secreted SDF-1 protein levels were quantified, and MSCs migration was evaluated with or without blocking SDF-1/CXCR4 pathway by AMD3100. For in vivo study, fractured 8-week-old young rats received intracardiac administration of MSCs were assigned to LIPUS treatment, LIPUS+AMD3100 treatment or vehicle control group. The migration of transplanted MSC to the fracture site was investigated by ex vivo fluorescent imaging. SDF-1 protein levels at fracture site and in serum were examined. Fracture healing parameters, including callus morphology, micro-architecture of the callus and biomechanical properties of the healing bone were investigated. The in vitro results showed that LIPUS upregulated SDF-1 and CXCR4 expressions in MSCs, and elevated SDF-1 protein level in the conditioned medium. MSCs migration was promoted by LIPUS and partially inhibited by AMD3100. In vivo study demonstrated that LIPUS promoted MSCs migration to the fracture site, which was associated with an increase of local and serum SDF-1 level, the changes in callus formation, and the improvement of callus microarchitecture and mechanical properties; whereas the blockade of SDF-1/CXCR4 signaling attenuated the LIPUS effects on the fractured bones. These results suggested SDF-1 mediated MSCs migration might be one of the crucial mechanisms through which LIPUS exerted influence on fracture healing.
Collapse
Affiliation(s)
- Fang-Yuan Wei
- Department of Orthopaedics and Traumatology, Clinical Sciences Building, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
| | - Kwok-Sui Leung
- Department of Orthopaedics and Traumatology, Clinical Sciences Building, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
- Translational Medicine Research & Development Center, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Gang Li
- Department of Orthopaedics and Traumatology, Clinical Sciences Building, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
| | - Jianghui Qin
- Department of Orthopaedics and Traumatology, Clinical Sciences Building, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
| | - Simon Kwoon-Ho Chow
- Department of Orthopaedics and Traumatology, Clinical Sciences Building, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
| | - Shuo Huang
- Department of Orthopaedics and Traumatology, Clinical Sciences Building, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
| | - Ming-Hui Sun
- Department of Orthopaedics and Traumatology, Clinical Sciences Building, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
| | - Ling Qin
- Department of Orthopaedics and Traumatology, Clinical Sciences Building, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
- Translational Medicine Research & Development Center, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Wing-Hoi Cheung
- Department of Orthopaedics and Traumatology, Clinical Sciences Building, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
- Translational Medicine Research & Development Center, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| |
Collapse
|
19
|
Padilla F, Puts R, Vico L, Raum K. Stimulation of bone repair with ultrasound: a review of the possible mechanic effects. ULTRASONICS 2014; 54:1125-45. [PMID: 24507669 DOI: 10.1016/j.ultras.2014.01.004] [Citation(s) in RCA: 136] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2013] [Revised: 12/20/2013] [Accepted: 01/07/2014] [Indexed: 05/15/2023]
Abstract
In vivo and in vitro studies have demonstrated the positive role that ultrasound can play in the enhancement of fracture healing or in the reactivation of a failed healing process. We review the several options available for the use of ultrasound in this context, either to induce a direct physical effect (LIPUS, shock waves), to deliver bioactive molecules such as growth factors, or to transfect cells with osteogenic plasmids; with a main focus on LIPUS (or Low Intensity Pulsed Ultrasound) as it is the most widespread and studied technique. The biological response to LIPUS is complex as numerous cell types respond to this stimulus involving several pathways. Known to-date mechanotransduction pathways involved in cell responses include MAPK and other kinases signaling pathways, gap-junctional intercellular communication, up-regulation and clustering of integrins, involvement of the COX-2/PGE2, iNOS/NO pathways and activation of ATI mechanoreceptor. The mechanisms by which ultrasound can trigger these effects remain intriguing. Possible mechanisms include direct and indirect mechanical effects like acoustic radiation force, acoustic streaming, and propagation of surface waves, fluid-flow induced circulation and redistribution of nutrients, oxygen and signaling molecules. Effects caused by the transformation of acoustic wave energy into heat can usually be neglected, but heating of the transducer may have a potential impact on the stimulation in some in-vitro systems, depending on the coupling conditions. Cavitation cannot occur at the pressure levels delivered by LIPUS. In-vitro studies, although not appropriate to identify the overall biological effects, are of great interest to study specific mechanisms of action. The diversity of current experimental set-ups however renders this analysis very complex, as phenomena such as transducer heating, inhomogeneities of the sound intensity in the near field, resonances in the transmission and reflection through the culture dish walls and the formation of standing waves will greatly affect the local type and amplitude of the stimulus exerted on the cells. A future engineering challenge is therefore the design of dedicated experimental set-ups, in which the different mechanical phenomena induced by ultrasound can be controlled. This is a prerequisite to evaluate the biological effects of the different phenomena with respect to particular parameters, like intensity, frequency, or duty cycle. By relating the variations of these parameters to the induced physical effects and to the biological responses, it will become possible to derive an 'acoustic dose' and propose a quantification and cross-calibration of the different experimental systems. Improvements in bone healing management will probably also come from a combination of ultrasound with a 'biologic' components, e.g. growth factors, scaffolds, gene therapies, or drug delivery vehicles, the effects of which being potentiated by the ultrasound.
Collapse
Affiliation(s)
- Frédéric Padilla
- Inserm, U1032, LabTau, Lyon F-69003, France; Université de Lyon, Lyon F-69003, France.
| | - Regina Puts
- Julius Wolff Institut & Berlin-Brandenburg School for Regenerative Therapies, Charité - Universitätsmedizin Berlin, Germany
| | - Laurence Vico
- Inserm U1059 Lab Biologie intégrée du Tissu Osseux, Université de Lyon, St-Etienne F-42023, France
| | - Kay Raum
- Julius Wolff Institut & Berlin-Brandenburg School for Regenerative Therapies, Charité - Universitätsmedizin Berlin, Germany
| |
Collapse
|
20
|
Fung CH, Cheung WH, Pounder NM, Harrison A, Leung KS. Osteocytes exposed to far field of therapeutic ultrasound promotes osteogenic cellular activities in pre-osteoblasts through soluble factors. ULTRASONICS 2014; 54:1358-1365. [PMID: 24560187 DOI: 10.1016/j.ultras.2014.02.003] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2013] [Revised: 01/17/2014] [Accepted: 02/02/2014] [Indexed: 06/03/2023]
Abstract
Low intensity pulsed ultrasound (LIPUS) was reported to accelerate the rate of fracture healing. When LIPUS is applied to fractures transcutaneously, bone tissues at different depths are exposed to different ultrasound fields. Measurement of LIPUS shows pressure variations in near field (nearby transducer); uniform profile was found beyond it (far field). Moreover, we have reported that the therapeutic effect of LIPUS is dependent on the axial distance of ultrasound beam in rat fracture model. However, the mechanisms of how different axial distances of LIPUS influence the mechanotransduction of bone cells are not understood. To understand the cellular mechanisms underlying far field LIPUS on enhanced fracture healing in rat model, the present study investigated the effect of ultrasound axial distances on (1) osteocyte, the mechanosensor, and (2) mechanotransduction between osteocyte and pre-osteoblast (bone-forming cell) through paracrine signaling. We hypothesized that far field LIPUS could enhance the osteogenic activities of osteoblasts via paracrine factors secreted from osteocytes. The objective of this study was to investigate the effect of axial distances of LIPUS on osteocytes and osteocyte-osteoblast mechanotransduction. In this study, LIPUS (plane; 2.2 cm in diameter, 1.5MHz sine wave, ISATA=30 mW/cm(2)) was applied to osteocytes (mechanosensor) at three axial distances: 0mm (near field), 60mm (mid-near field) and 130 mm (far field). The conditioned medium of osteocytes (OCM) collected from these three groups were used to culture pre-osteoblasts (effector cell). In this study, (1) the direct effect of ultrasound fields on the mechanosensitivity of osteocytes; and (2) the osteogenic effect of different OCM treatments on pre-osteoblasts were assessed. The immunostaining results indicated the ultrasound beam at far field resulted in more β-catenin nuclear translocation in osteocytes than all other groups. This indicated that osteocytes could detect the acoustic differences of LIPUS at various axial distances. Furthermore, we found that the soluble factors secreted by far field LIPUS exposed osteocytes could further promote pre-osteoblasts cell migration, maturation (transition of cell proliferation into osteogenic differentiation), and matrix calcification. In summary, our results of this present study indicated that axial distance beyond near field could transmit ultrasound energy to osteocyte more efficiently. The LIPUS exposed osteocytes conveyed mechanical signals to pre-osteoblasts and regulated their osteogenic cellular activities via paracrine factors secretion. The soluble factors secreted by far field exposed osteocytes led to promotion in migration and maturation in pre-osteoblasts. This finding demonstrated the positive effects of far field LIPUS on stimulating osteocytes and promoting mechanotransduction between osteocytes and osteoblasts.
Collapse
Affiliation(s)
- Chak-Hei Fung
- Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong, China
| | - Wing-Hoi Cheung
- Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong, China; Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China.
| | - Neill M Pounder
- Orthopaedic Trauma and Clinical Therapies, Smith and Nephew, Inc., Durham, NC 27703, United States
| | - Andrew Harrison
- Orthopaedic Trauma and Clinical Therapies, Smith and Nephew, Inc., Durham, NC 27703, United States
| | - Kwok-Sui Leung
- Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong, China; Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China
| |
Collapse
|
21
|
Fung CH, Cheung WH, Pounder NM, de Ana FJ, Harrison A, Leung KS. Investigation of rat bone fracture healing using pulsed 1.5 MHz, 30 mW/cm(2) burst ultrasound--axial distance dependency. ULTRASONICS 2014; 54:850-859. [PMID: 24239510 DOI: 10.1016/j.ultras.2013.10.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2013] [Revised: 10/16/2013] [Accepted: 10/16/2013] [Indexed: 06/02/2023]
Abstract
This study investigated the effect of LIPUS on fracture healing when fractures were exposed to ultrasound at three axial distances: z=0 mm, 60 mm, and 130 mm. We applied LIPUS to rat fracture at these three axial distances mimicking the exposure condition of human fractures at different depths under the soft tissue. Measurement of LIPUS shows pressure variations in near field (nearby transducer); uniform profile was found beyond it (far field). We asked whether different positions of the fracture within the ultrasound field cause inconsistent biological effect during the healing process. Closed femoral fractured Sprague-Dawley rats were randomized into control, near-field (0mm), mid-near field (60 mm) or far-field (130 mm) groups. Daily LIPUS treatment (plane, but apodized source, see details in the text; 2.2 cm in diameter; 1.5 MHz sine waves repeating at 1 kHz PRF; spatial average temporal average intensity, ISATA=30 mW/cm(2)) was given to fracture site at the three axial distances. Weekly radiographs and endpoint microCT, histomorphometry, and mechanical tests were performed. The results showed that the 130 mm group had the highest tissue mineral density; and significantly higher mechanical properties than control at week 4. The 60 mm and 0 mm groups had significantly higher (i.e. p<0.05) woven bone percentage than control group in radiological, microCT and histomorphometry measurements. In general, LIPUS at far field augmented callus mineralization and mechanical properties; while near field and mid-near field enhanced woven bone formation. Our results indicated the therapeutic effect of LIPUS is dependent on the axial distance of the ultrasound beam. Therefore, the depth of fracture under the soft tissue affects the biological effect of LIPUS. Clinicians have to be aware of the fracture depth when LIPUS is applied transcutaneously.
Collapse
Affiliation(s)
- Chak-Hei Fung
- Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong, China
| | - Wing-Hoi Cheung
- Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong, China; Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China.
| | - Neill M Pounder
- Orthopaedic Trauma and Clinical Therapies, Smith and Nephew, Inc., Durham, NC 27703, United States
| | - F Javier de Ana
- Orthopaedic Trauma and Clinical Therapies, Smith and Nephew, Inc., Durham, NC 27703, United States
| | - Andrew Harrison
- Orthopaedic Trauma and Clinical Therapies, Smith and Nephew, Inc., Durham, NC 27703, United States
| | - Kwok-Sui Leung
- Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong, China; Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China
| |
Collapse
|
22
|
Alassaf A, Aleid A, Frenkel V. In vitro methods for evaluating therapeutic ultrasound exposures: present-day models and future innovations. J Ther Ultrasound 2013; 1:21. [PMID: 25093079 PMCID: PMC4109267 DOI: 10.1186/2050-5736-1-21] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2013] [Accepted: 09/09/2013] [Indexed: 11/30/2022] Open
Abstract
Although preclinical experiments are ultimately required to evaluate new therapeutic ultrasound exposures and devices prior to clinical trials, in vitro experiments can play an important role in the developmental process. A variety of in vitro methods have been developed, where each of these has demonstrated their utility for various test purposes. These include inert tissue-mimicking phantoms, which can incorporate thermocouples or cells and ex vivo tissue. Cell-based methods have also been used, both in monolayer and suspension. More biologically relevant platforms have also shown utility, such as blood clots and collagen gels. Each of these methods possesses characteristics that are well suited for various well-defined investigative goals. None, however, incorporate all the properties of real tissues, which include a 3D environment and live cells that may be maintained long-term post-treatment. This review is intended to provide an overview of the existing application-specific in vitro methods available to therapeutic ultrasound investigators, highlighting their advantages and limitations. Additional reporting is presented on the exciting and emerging field of 3D biological scaffolds, employing methods and materials adapted from tissue engineering. This type of platform holds much promise for achieving more representative conditions of those found in vivo, especially important for the newest sphere of therapeutic applications, based on molecular changes that may be generated in response to non-destructive exposures.
Collapse
Affiliation(s)
- Ahmad Alassaf
- Department of Biomedical Engineering, Catholic University of America, 620 Michigan Ave NE, Washington, DC 20064, USA
| | - Adham Aleid
- Department of Biomedical Engineering, Catholic University of America, 620 Michigan Ave NE, Washington, DC 20064, USA
| | - Victor Frenkel
- Department of Biomedical Engineering, Catholic University of America, 620 Michigan Ave NE, Washington, DC 20064, USA
| |
Collapse
|
23
|
Low-intensity pulsed ultrasound accelerates tooth movement via activation of the BMP-2 signaling pathway. PLoS One 2013; 8:e68926. [PMID: 23894376 PMCID: PMC3720872 DOI: 10.1371/journal.pone.0068926] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2013] [Accepted: 06/03/2013] [Indexed: 12/16/2022] Open
Abstract
The present study was designed to determine the underlying mechanism of low-intensity pulsed ultrasound (LIPUS) induced alveolar bone remodeling and the role of BMP-2 expression in a rat orthodontic tooth movement model. Orthodontic appliances were placed between the homonymy upper first molars and the upper central incisors in rats under general anesthesia, followed by daily 20-min LIPUS or sham LIPUS treatment beginning at day 0. Tooth movement distances and molecular changes were evaluated at each observation point. In vitro and in vivo studies were conducted to detect HGF (Hepatocyte growth factor)/Runx2/BMP-2 signaling pathways and receptor activator of NFκB ligand (RANKL) expression by quantitative real time PCR (qRT-PCR), Western blot and immunohistochemistry. At day 3, LIPUS had no effect on the rat orthodontic tooth movement distance and BMP-2-induced alveolar bone remodeling. However, beginning at day 5 and for the following time points, LIPUS significantly increased orthodontic tooth movement distance and BMP-2 signaling pathway and RANKL expression compared with the control group. The qRT-PCR and Western blot data in vitro and in vivo to study BMP-2 expression were consistent with the immunohistochemistry observations. The present study demonstrates that LIPUS promotes alveolar bone remodeling by stimulating the HGF/Runx2/BMP-2 signaling pathway and RANKL expression in a rat orthodontic tooth movement model, and LIPUS increased BMP-2 expression via Runx2 regulation.
Collapse
|
24
|
Al-Daghreer S, Doschak M, Sloan AJ, Major PW, Heo G, Scurtescu C, Tsui YY, El-Bialy T. Short-term effect of low-intensity pulsed ultrasound on an ex-vivo 3-d tooth culture. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1066-1074. [PMID: 23499341 DOI: 10.1016/j.ultrasmedbio.2012.12.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2012] [Revised: 12/07/2012] [Accepted: 12/11/2012] [Indexed: 06/01/2023]
Abstract
We investigated the short-term effect of LIPUS on human dentin-pulp complex in vitro. We collected sixty-three premolars from patients who needed the extraction. The premolars were sectioned transversely into 600-μm-thick slices, and then divided into five groups according to LIPUS application time (control, 5, 10, 15 and 20 min). LIPUS transducer produced an incident intensity of 30 mW/cm(2). After 24 h, tissue was harvested for histomorphometrical analysis and RT-PCR (Genes of interest: Collagen I, DMP1, DSPP, TGF β1, RANKL and OPG). Histomorphometric analysis showed no significant difference among the five groups in the odontoblast count and predentin thickness. RT-PCR demonstrated no expression of TGF β1, low amounts of DSPP, a twofold increase in collagen I expression in the 5- and 10-minute LIPUS groups and a threefold increase in DMP1 expression in the 10-minute LIPUS group. LIPUS application was stimulatory to the dentin-pulp complex in vitro and increased the expression of collagen I and DMP1.
Collapse
Affiliation(s)
- Saleh Al-Daghreer
- University of Alberta, Department of Dentistry, Faculty of Medicine & Dentistry, Orthodontic Graduate Program, Edmonton, AB, Canada.
| | | | | | | | | | | | | | | |
Collapse
|