Basavarajappa L, Rijal G, Hoyt K. Multifocused Ultrasound Therapy for Controlled Microvascular Permeabilization and Improved Drug Delivery. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:961-968. [PMID: 32976098 PMCID: PMC8034541 DOI: 10.1109/tuffc.2020.3026697] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Focused ultrasound (FUS) exposure of micro-bubble (MB) contrast agents can transiently increase microvascular permeability allowing anticancer drugs to extravasate into a targeted tumor tissue. Either fixed or mechanically steered in space, most studies to date have used a single element focused transducer to deliver the ultrasound (US) energy. The goal of this study was to investigate various multi-FUS strategies implemented on a programmable US scanner (Vantage 256, Verasonics Inc.) equipped with a linear array for image guidance and a 128-element therapy transducer (HIFUPlex-06, Sonic Concepts). The multi-FUS strategies include multi-FUS with sequential excitation (multi-FUS-SE) and multi-FUS with temporal sequential excitation (multi-FUS-TSE) and were compared to single-FUS and sham treatment. This study was performed using athymic mice implanted with breast cancer cells ( N = 20 ). FUS therapy experiments were performed for 10 min after a solution containing MBs (Definity, Lantheus Medical Imaging Inc.) and near-infrared (NIR, surrogate drug) dye were injected via the tail vein. The fluorescent signal was monitored using an in vivo optical imaging system (Pearl Trilogy, LI-COR) to quantify intratumoral dye accumulation at baseline and again at 0.1, 24, and 48 h after receiving US therapy. Animals were then euthanized for ex vivo dye extraction analysis. At 48 h, fluorescent tracer accumulation within the tumor space for the multi-FUS-TSE therapy group animals was found to be 67.3%, 50.3%, and 36.2% higher when compared to sham, single-FUS, and multi-FUS-SE therapy group measures, respectively. Also, dye extraction and fluorescence measurements from excised tumor tissue found increases of 243.2%, 163.1%, and 68.1% for the multi-FUS-TSE group compared to sham, single-FUS, and multi-FUS-SE therapy group measures, respectively. In summary, experimental results revealed that for a multi-FUS sequence, increased microvascular permeability was considerably influenced by both the spatial and temporal aspects of the applied US therapy.
Collapse
|
2
|
Abstract
Mutations in approximately 80 genes have been implicated as the cause of various genetic kidney diseases. However, gene delivery to kidney cells from the blood is inefficient because of the natural filtering functions of the glomerulus, and research into and development of gene therapy directed toward kidney disease has lagged behind as compared with hepatic, neuromuscular, and ocular gene therapy. This lack of progress is in spite of numerous genetic mouse models of human disease available to the research community and many vectors in existence that can theoretically deliver genes to kidney cells with high efficiency. In the past decade, several groups have begun to develop novel injection techniques in mice, such as retrograde ureter, renal vein, and direct subcapsular injections to help resolve the issue of gene delivery to the kidney through the blood. In addition, the ability to retarget vectors specifically toward kidney cells has been underutilized but shows promise. This review discusses how recent advances in gene delivery to the kidney and the field of gene therapy can leverage the wealth of knowledge of kidney genetics to work toward developing gene therapy products for patients with kidney disease.
Collapse
Affiliation(s)
- Jeffrey D Rubin
- Virology and Gene Therapy Graduate Program, Mayo Clinic, Rochester, MN, USA
| | - Michael A Barry
- Division of Infectious Diseases, Department of Internal Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN, USA.
- Department of Immunology, Mayo Clinic, Rochester, MN, USA.
- Department of Molecular Medicine, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
3
|
Xiong F, Nirupama S, Sirsi SR, Lacko A, Hoyt K. Ultrasound-Stimulated Drug Delivery Using Therapeutic Reconstituted High-Density Lipoprotein Nanoparticles. Nanotheranostics 2017; 1:440-449. [PMID: 29188177 PMCID: PMC5704009 DOI: 10.7150/ntno.21905] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2017] [Accepted: 10/09/2017] [Indexed: 12/20/2022] Open
Abstract
The abnormal tumor vasculature and the resulting abnormal microenvironment are major barriers to optimal chemotherapeutic drug delivery. It is well known that ultrasound (US) can increase the permeability of the tumor vessel walls and enhance the accumulation of anticancer agents. Reconstituted high-density lipoproteins (rHDL) nanoparticles (NPs) allow selective delivery of anticancer agents to tumor cells via their overexpressed scavenger receptor type B1 (SR-B1) receptor. The goal of this study is to investigate the potential of noninvasive US therapy to further improve delivery and tumor uptake of the payload from rHDL NPs, preloaded with an infrared dye (IR-780), aimed to establish a surrogate chemotherapeutic model with optical localization. Athymic nude mice were implanted orthotopically with one million breast cancer cells (MDA-MB-231/Luc). Three weeks later, animals were divided into seven groups with comparable mean tumor size: control, low, moderate, and high concentration of rHDL NPs alone groups, as well as these three levels of rHDL NPs plus US therapy groups (N = 7 to 12 animals per group), where low, moderate and high denote 5, 10, and 50 µg of the IR-780 dye payload per rHDL NP injection, respectively. The US therapy system included a single element focused transducer connected in series with a function generator and power amplifier. A custom 3D printed cone with an acoustically transparent aperture and filled with degassed water allowed delivery of focused US energy to the tumor tissue. US exposure involved a pulsed sequence applied for a duration of 5 min. Each animal in the US therapy groups received a slow bolus co-injection of MB contrast agent and rHDL NPs. Animals were imaged using a whole-body optical system to quantify intratumoral rHDL NP accumulation at baseline and again at 1 min, 30 min, 24 h, and 48 h. At 48 h, all animals were euthanized and tumors were excised for ex vivo analysis. We investigated a noninvasive optical imaging method for monitoring the effects of US-stimulated drug delivery of IR-780 dye-loaded rHDL NPs in living animals. No change in optical imaging data was found in the control animals. However, there was considerable dye accumulation (surrogate drug) within 48 h in the low (5 µg), moderate (10 µg), and high (50 µg) rHDL NP concentration-dosed group animals (p < 0.09). With US therapy added to the experimental protocol, there was an additional and significant increase in local tumor drug uptake at 48 h (p < 0.02). Optical image data collected from ex vivo tumor samples confirmed tumor retention of the IR-780 dye-loaded rHDL NPs and correlated positively with in vivo optical imaging results (R2 > 0.69, p < 0.003). IR-780 dye extraction from the tumor tissue samples confirmed the in vivo and ex vivo US therapy findings. Overall, the addition of US therapy considerably improved local rHDL NP accumulation in tumor tissue. This study concludes that US-mediated drug delivery can facilitate tumor uptake of rHDL NPs and more research is warranted to optimize the drug dosing schedule and the respective therapeutic protocols.
Collapse
Affiliation(s)
- Fangyuan Xiong
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080 USA.,Department of Medical Ultrasound, Tongji Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Sabnis Nirupama
- Department of Pediatrics, University of North Texas Health Sciences Center, Fort Worth TX 76107 USA
| | - Shashank R Sirsi
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080 USA.,Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX 75390 USA
| | - Andras Lacko
- Department of Pediatrics, University of North Texas Health Sciences Center, Fort Worth TX 76107 USA
| | - Kenneth Hoyt
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080 USA.,Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX 75390 USA
| |
Collapse
|
4
|
Chen J, Ratnayaka S, Alford A, Kozlovskaya V, Liu F, Xue B, Hoyt K, Kharlampieva E. Theranostic Multilayer Capsules for Ultrasound Imaging and Guided Drug Delivery. ACS NANO 2017; 11:3135-3146. [PMID: 28263564 PMCID: PMC5682940 DOI: 10.1021/acsnano.7b00151] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Despite the accessibility of ultrasound, the clinical potential of ultrasound-active theranostic agents has not been fully realized because it requires combining sufficient imaging contrast, high encapsulation efficiency, and ultrasound-triggered release in one entity. We report on theranostic polymer microcapsules composed of hydrogen-bonded multilayers of tannic acid and poly(N-vinylpyrrolidone) that produce high imaging contrast and deliver the anticancer drug doxorubicin upon low-power diagnostic or high-power therapeutic ultrasound irradiation. These capsules exhibit excellent imaging contrast in both brightness and harmonic modes and show prolonged contrast over six months, unlike commercially available microbubbles. We also demonstrate low-dose gradual and high-dose fast release of doxorubicin from the capsules by diagnostic (∼100 mW/cm2) and therapeutic (>10 W/cm2) ultrasound irradiation, respectively. We show that the imaging contrast of the capsules can be controlled by varying the number of layers, polymer type (relatively rigid tannic acid versus more flexible poly(methacrylic acid)), and polymer molecular weight. In vitro studies demonstrate that 50% doxorubicin release from ultrasound-treated capsules induces 97% cytotoxicity to MCF-7 human cancer cells, while no cytotoxicity is found without the treatment. Considering the strong ultrasound imaging contrast, high encapsulation efficiency, biocompatibility, and tunable drug release, these microcapsules can be used as theranostic agents for ultrasound-guided chemotherapy.
Collapse
Affiliation(s)
- Jun Chen
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, Alabama 35294, United States
| | - Sithira Ratnayaka
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, Alabama 35294, United States
| | - Aaron Alford
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, Alabama 35294, United States
| | - Veronika Kozlovskaya
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, Alabama 35294, United States
| | - Fei Liu
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, Alabama 35294, United States
| | - Bing Xue
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, Alabama 35294, United States
| | - Kenneth Hoyt
- Department of Bioengineering, University of Texas at Dallas, Richardson, Texas 75080, United States
| | - Eugenia Kharlampieva
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, Alabama 35294, United States
| |
Collapse
|
5
|
Heun Y, Hildebrand S, Heidsieck A, Gleich B, Anton M, Pircher J, Ribeiro A, Mykhaylyk O, Eberbeck D, Wenzel D, Pfeifer A, Woernle M, Krötz F, Pohl U, Mannell H. Targeting of Magnetic Nanoparticle-coated Microbubbles to the Vascular Wall Empowers Site-specific Lentiviral Gene Delivery in vivo. Theranostics 2017; 7:295-307. [PMID: 28042335 PMCID: PMC5197065 DOI: 10.7150/thno.16192] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2016] [Accepted: 09/13/2016] [Indexed: 12/13/2022] Open
Abstract
In the field of vascular gene therapy, targeting systems are promising advancements to improve site-specificity of gene delivery. Here, we studied whether incorporation of magnetic nanoparticles (MNP) with different magnetic properties into ultrasound sensitive microbubbles may represent an efficient way to enable gene targeting in the vascular system after systemic application. Thus, we associated novel silicon oxide-coated magnetic nanoparticle containing microbubbles (SO-Mag MMB) with lentiviral particles carrying therapeutic genes and determined their physico-chemical as well as biological properties compared to MMB coated with polyethylenimine-coated magnetic nanoparticles (PEI-Mag MMB). While there were no differences between both MMB types concerning size and lentivirus binding, SO-Mag MMB exhibited superior characteristics regarding magnetic moment, magnetizability as well as transduction efficiency under static and flow conditions in vitro. Focal disruption of lentiviral SO-Mag MMB by ultrasound within isolated vessels exposed to an external magnetic field decisively improved localized VEGF expression in aortic endothelium ex vivo and enhanced the angiogenic response. Using the same system in vivo, we achieved a highly effective, site-specific lentiviral transgene expression in microvessels of the mouse dorsal skin after arterial injection. Thus, we established a novel lentiviral MMB technique, which has great potential towards site-directed vascular gene therapy.
Collapse
|
6
|
Uncertainty estimation for temperature measurement with diagnostic ultrasound. J Ther Ultrasound 2016; 4:28. [PMID: 27957332 PMCID: PMC5131492 DOI: 10.1186/s40349-016-0071-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Accepted: 10/01/2016] [Indexed: 12/16/2022] Open
Abstract
Background Ultrasound therapies are promising, non-invasive applications with potential to significantly improve, e.g. cancer therapies like viro- or immunotherapy or surgical applications. However, a crucial step towards their breakthrough is still missing: affordable and easy-to-handle quality assurance tools for therapy devices and ways to verify treatment planning algorithms. This deficiency limits the safety and comparability of treatments. Methods To overcome this deficiency accurate spatial and temporal temperature maps could be used. In this paper, the suitability of temperature calculation based on time-shifts of diagnostic ultrasound backscattered signals (echo-time-shift) is investigated and associated uncertainties are estimated. Different analysis variations were used to calculate the time-shifts: discrete and continuous methods as well as different frames as a reference for temperature calculation (4 s before, 16 s before the frame of interest, base frame). A sigmoid function was fitted and used to calculate temperatures. Two-dimensional temperature maps recorded during and after therapeutic ultrasound sonication were examined. All experiments were performed in agar-graphite phantoms mimicking non-fatty tissue, with high-intensity focused ultrasound being the source of heating. Results Continuous methods are more accurate than discrete ones, and uncertainties of calculated temperatures are in general lower, the earlier the reference frame was recorded. Depending on the purpose of the measurement, a compromise has to be made between the following: calculation accuracy (early reference frame), tolerance towards small movements (late reference frame), reproducing large temperature changes or cooling processes (reference frame at a certain point in time), speed of the algorithm (discrete (fast) vs. continuous (slower) shift calculation), and spatial accuracy (interval size for index-shift calculation). Within the range from 20 °C to 44 °C, uncertainties as low as 12.4 % are possible, being mainly due to medium properties. Conclusions Temperature measurements using the echo-time-shift method might be useful for validation of treatment plan algorithms. This might also be a comparatively accurate, fast, and affordable method for laboratory and clinical quality assessment. Further research is necessary to improve filter algorithms and to extend this method to multiple foci and the usage of temperature-dependent tissue quantities. We used an analytical approach to investigate the uncertainties of temperature measurement. Different analysis variations are compared to determine temperature distribution and development over time.
Collapse
|
7
|
Timbie KF, Mead BP, Price RJ. Drug and gene delivery across the blood-brain barrier with focused ultrasound. J Control Release 2015; 219:61-75. [PMID: 26362698 DOI: 10.1016/j.jconrel.2015.08.059] [Citation(s) in RCA: 139] [Impact Index Per Article: 15.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2015] [Revised: 08/26/2015] [Accepted: 08/31/2015] [Indexed: 12/31/2022]
Abstract
The blood-brain barrier (BBB) remains one of the most significant limitations to treatments of central nervous system (CNS) disorders including brain tumors, neurodegenerative diseases and psychiatric disorders. It is now well-established that focused ultrasound (FUS) in conjunction with contrast agent microbubbles may be used to non-invasively and temporarily disrupt the BBB, allowing localized delivery of systemically administered therapeutic agents as large as 100nm in size to the CNS. Importantly, recent technological advances now permit FUS application through the intact human skull, obviating the need for invasive and risky surgical procedures. When used in combination with magnetic resonance imaging, FUS may be applied precisely to pre-selected CNS targets. Indeed, FUS devices capable of sub-millimeter precision are currently in several clinical trials. FUS mediated BBB disruption has the potential to fundamentally change how CNS diseases are treated, unlocking potential for combinatorial treatments with nanotechnology, markedly increasing the efficacy of existing therapeutics that otherwise do not cross the BBB effectively, and permitting safe repeated treatments. This article comprehensively reviews recent studies on the targeted delivery of therapeutics into the CNS with FUS and offers perspectives on the future of this technology.
Collapse
Affiliation(s)
- Kelsie F Timbie
- Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
| | - Brian P Mead
- Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
| | - Richard J Price
- Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA.
| |
Collapse
|
8
|
Ji Y, Han Z, Shao L, Zhao Y. Antitumor effects of combining tumor radiation with the antivascular action of ultrasound stimulated microbubbles. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY 2015; 8:9958-9974. [PMID: 26617705 PMCID: PMC4637790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Accepted: 08/20/2015] [Indexed: 06/05/2023]
Abstract
OBJECTIVE More and more evidence indicates tumor vasculature plays an important role in tumor radiation response. In this study, we investigated ultrasound stimulated microbubbles to enhance the effects of radiation. METHODS Human bladder cancer HT-1376 xenografts in severe combined immuno-deficient mice were used. High-frequency (25 MHz) ultrasound was used to image tumor responses caused by ultrasound-stimulated microbubbles in combination with radiation. Human bladder xenografts grown in severe combined immunodeficiency (SCID) mice were treated using microbubbles stimulated with ultrasound at 250, 570, or 750 kPa, and exposed to 0, 2, or 8 Gy of radiation. Tumors were imaged prior to treatment and 24 hours after treatment. Spectral analysis of images acquired from treated tumors revealed overall increases in ultrasound backscatter intensity and the spectral intercept parameter. RESULTS There existed a synergistic effect in vivo with combined single treatments of ultrasound-stimulated microbubble vascular perturbation and radiation inducing an over 10-fold greater cell kill with combined treatments. We further demonstrate that induction of ceramide-related endothelial cell apoptosis, leading to vascular disruption, is a causative mechanism. In vivo experiments with ultrasound and bubbles permit radiation doses to be decreased significantly for comparable effect. CONCLUSION We envisage this unique combined ultrasound-based vascular perturbation and radiation treatment method being used to enhance the effects of radiation in a tumor, leading to greater tumor eradication.
Collapse
Affiliation(s)
- Yanlei Ji
- Department of Special Diagnosis, Shandong Cancer Hospital and InstituteChina
| | - Zhen Han
- Department of Internal Medicine, Jinan Second People’s HospitalChina
| | - Limei Shao
- Department of Special Diagnosis, Shandong Cancer Hospital and InstituteChina
| | - Yuehuan Zhao
- Department of Special Diagnosis, Shandong Cancer Hospital and InstituteChina
| |
Collapse
|