1
|
Pruijssen JT, Schreuder FHBM, Wilbers J, Kaanders JHAM, de Korte CL, Hansen HHG. Performance evaluation of commercial and non-commercial shear wave elastography implementations for vascular applications. ULTRASONICS 2024; 140:107312. [PMID: 38599075 DOI: 10.1016/j.ultras.2024.107312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 03/25/2024] [Accepted: 04/01/2024] [Indexed: 04/12/2024]
Abstract
BACKGROUND Shear wave elastography (SWE) is mainly used for stiffness estimation of large, homogeneous tissues, such as the liver and breasts. However, little is known about its accuracy and applicability in thin (∼0.5-2 mm) vessel walls. To identify possible performance differences among vendors, we quantified differences in measured wave velocities obtained by commercial SWE implementations of various vendors over different imaging depths in a vessel-mimicking phantom. For reference, we measured SWE values in the cylindrical inclusions and homogeneous background of a commercial SWE phantom. Additionally, we compared the accuracy between a research implementation and the commercially available clinical SWE on an Aixplorer ultrasound system in phantoms and in vivo in patients. METHODS SWE measurements were performed over varying depths (0-35 mm) using three ultrasound machines with four ultrasound probes in the homogeneous 20 kPa background and cylindrical targets of 10, 40, and 60 kPa of a multi-purpose phantom (CIRS-040GSE) and in the anterior and posterior wall of a homogeneous polyvinyl alcohol vessel-mimicking phantom. These phantom data, along with in vivo SWE data of carotid arteries in 23 patients with a (prior) head and neck neoplasm, were also acquired in the research and clinical mode of the Aixplorer ultrasound machine. Machine-specific estimated phantom stiffness values (CIRS phantom) or wave velocities (vessel phantom) over all depths were visualized, and the relative error to the reference values and inter-frame variability (interquartile range/median) were calculated. Correlations between SWE values and target/vessel wall depth were explored in phantoms and in vivo using Spearman's correlations. Differences in wave velocities between the anterior and posterior arterial wall were assessed with Wilcoxon signed-rank tests. Intra-class correlation coefficients were calculated for a sample of ten patients as a measure of intra- and interobserver reproducibility of SWE analyses in research and clinical mode. RESULTS There was a high variability in obtained SWE values among ultrasound machines, probes, and, in some cases, with depth. Compared to the homogeneous CIRS-background, this variation was more pronounced for the inclusions and the vessel-mimicking phantom. Furthermore, higher stiffnesses were generally underestimated. In the vessel-mimicking phantom, anterior wave velocities were (incorrectly) higher than posterior wave velocities (3.4-5.6 m/s versus 2.9-5.9 m/s, p ≤ 0.005 for 3/4 probes) and remarkably correlated with measurement depth for most machines (Spearman's ρ = -0.873-0.969, p < 0.001 for 3/4 probes). In the Aixplorer's research mode, this difference was smaller (3.3-3.9 m/s versus 3.2-3.6 m/s, p = 0.005) and values did not correlate with measurement depth (Spearman's ρ = 0.039-0.659, p ≥ 0.002). In vivo, wave velocities were higher in the posterior than the anterior vessel wall in research (left p = 0.001, right p < 0.001) but not in clinical mode (left: p = 0.114, right: p = 0.483). Yet, wave velocities correlated with vessel wall depth in clinical (Spearman's ρ = 0.574-0.698, p < 0.001) but not in research mode (Spearman's ρ = -0.080-0.466, p ≥ 0.003). CONCLUSIONS We observed more variation in SWE values among ultrasound machines and probes in tissue with high stiffness and thin-walled geometry than in low stiffness, homogeneous tissue. Together with a depth-correlation in some machines, where carotid arteries have a fixed location, this calls for caution in interpreting SWE results in clinical practice for vascular applications.
Collapse
Affiliation(s)
- Judith T Pruijssen
- Medical Ultrasound Imaging Center (MUSIC), Department of Medical Imaging/Radiology, Radboud university medical center, Nijmegen, the Netherlands.
| | - Floris H B M Schreuder
- Department of Neurology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Joyce Wilbers
- Center of Expertise for Cancer Survivorship, Radboud university medical center, Nijmegen, the Netherlands
| | - Johannes H A M Kaanders
- Department of Radiation Oncology, Radboud university medical center, Nijmegen, the Netherlands
| | - Chris L de Korte
- Medical Ultrasound Imaging Center (MUSIC), Department of Medical Imaging/Radiology, Radboud university medical center, Nijmegen, the Netherlands; Physics of Fluid Group, MESA+ Institute for Nanotechnology, and MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands
| | - Hendrik H G Hansen
- Medical Ultrasound Imaging Center (MUSIC), Department of Medical Imaging/Radiology, Radboud university medical center, Nijmegen, the Netherlands
| |
Collapse
|
2
|
Bianchini E, Guala A, Golemati S, Alastruey J, Climie RE, Dalakleidi K, Francesconi M, Fuchs D, Hartman Y, Malik AEF, Makūnaitė M, Nikita KS, Park C, Pugh CJA, Šatrauskienė A, Terentes-Printizios D, Teynor A, Thijssen D, Schmidt-Trucksäss A, Zupkauskienė J, Boutouyrie P, Bruno RM, Reesink KD. The Ultrasound Window Into Vascular Ageing: A Technology Review by the VascAgeNet COST Action. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2023; 42:2183-2213. [PMID: 37148467 DOI: 10.1002/jum.16243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 03/24/2023] [Accepted: 04/14/2023] [Indexed: 05/08/2023]
Abstract
Non-invasive ultrasound (US) imaging enables the assessment of the properties of superficial blood vessels. Various modes can be used for vascular characteristics analysis, ranging from radiofrequency (RF) data, Doppler- and standard B/M-mode imaging, to more recent ultra-high frequency and ultrafast techniques. The aim of the present work was to provide an overview of the current state-of-the-art non-invasive US technologies and corresponding vascular ageing characteristics from a technological perspective. Following an introduction about the basic concepts of the US technique, the characteristics considered in this review are clustered into: 1) vessel wall structure; 2) dynamic elastic properties, and 3) reactive vessel properties. The overview shows that ultrasound is a versatile, non-invasive, and safe imaging technique that can be adopted for obtaining information about function, structure, and reactivity in superficial arteries. The most suitable setting for a specific application must be selected according to spatial and temporal resolution requirements. The usefulness of standardization in the validation process and performance metric adoption emerges. Computer-based techniques should always be preferred to manual measures, as long as the algorithms and learning procedures are transparent and well described, and the performance leads to better results. Identification of a minimal clinically important difference is a crucial point for drawing conclusions regarding robustness of the techniques and for the translation into practice of any biomarker.
Collapse
Affiliation(s)
| | - Andrea Guala
- Vall d'Hebron Institut de Recerca (VHIR), Barcelona, Spain
- CIBERCV, Instituto de Salud Carlos III, Madrid, Spain
| | - Spyretta Golemati
- Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Jordi Alastruey
- Department of Biomedical Engineering, King's College London, London, UK
| | - Rachel E Climie
- Menzies Institute for Medical Research, University of Tasmania, Hobart, Tasmania, Australia
- INSERM, U970, Paris Cardiovascular Research Center (PARCC), Université de Paris, Hopital Europeen Georges Pompidou - APHP, Paris, France
| | - Kalliopi Dalakleidi
- Biomedical Simulations and Imaging (BIOSIM) Laboratory, School of Electrical and Computer Engineering, National Technical University of Athens, Athens, Greece
| | - Martina Francesconi
- Institute of Clinical Physiology, CNR, Pisa, Italy
- University of Pisa, Pisa, Italy
| | - Dieter Fuchs
- Fujifilm VisualSonics, Amsterdam, The Netherlands
| | - Yvonne Hartman
- Department of Physiology, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Afrah E F Malik
- CARIM School for Cardiovascular Diseases and Heart and Vascular Center, Maastricht University Medical Center+, Maastricht, The Netherlands
| | - Monika Makūnaitė
- Biomedical Engineering Institute, Kaunas University of Technology, Kaunas, Lithuania
| | - Konstantina S Nikita
- Biomedical Simulations and Imaging (BIOSIM) Laboratory, School of Electrical and Computer Engineering, National Technical University of Athens, Athens, Greece
| | - Chloe Park
- MRC Unit for Lifelong Health and Ageing, University College London, London, UK
| | - Christopher J A Pugh
- Cardiff School of Sport & Health Sciences, Cardiff Metropolitan University, Cardiff, UK
| | - Agnė Šatrauskienė
- Clinic of Cardiac and Vascular Diseases, Institute of Clinical Medicine, Faculty of Medicine, Vilnius University, Vilnius, Lithuania
- Centre of Cardiology and Angiology, Vilnius University Hospital Santaros klinikos, Vilnius, Lithuania
| | - Dimitrios Terentes-Printizios
- First Department of Cardiology, Hippokration Hospital, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Alexandra Teynor
- Faculty of Computer Science, Augsburg University of Applied Sciences, Augsburg, Germany
| | - Dick Thijssen
- Department of Physiology, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Arno Schmidt-Trucksäss
- Department of Sport, Exercise and Health, Division Sport and Exercise Medicine, University of Basel, Basel, Switzerland
| | - Jūratė Zupkauskienė
- Clinic of Cardiac and Vascular Diseases, Institute of Clinical Medicine, Faculty of Medicine, Vilnius University, Vilnius, Lithuania
| | - Pierre Boutouyrie
- INSERM, U970, Paris Cardiovascular Research Center (PARCC), Université de Paris, Hopital Europeen Georges Pompidou - APHP, Paris, France
| | - Rosa Maria Bruno
- INSERM, U970, Paris Cardiovascular Research Center (PARCC), Université de Paris, Hopital Europeen Georges Pompidou - APHP, Paris, France
| | - Koen D Reesink
- CARIM School for Cardiovascular Diseases and Heart and Vascular Center, Maastricht University Medical Center+, Maastricht, The Netherlands
| |
Collapse
|
3
|
Zhang X, Zheng Y, Li J, Zhang B. Application of the shear wave elastography in the assessment of carotid body tumors: A preliminary study. Front Oncol 2023; 12:1053236. [PMID: 36686815 PMCID: PMC9853190 DOI: 10.3389/fonc.2022.1053236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Accepted: 12/16/2022] [Indexed: 01/07/2023] Open
Abstract
Objectives To evaluate the elasticity of carotid body tumors (CBTs) by two-dimensional shear wave elastography (SWE). Methods 22 pathologically or clinically confirmed CBTs in 16 patients were scanned by SWE. The maximum elasticity value (Emax) and its standard deviation (SDmax) in kPa and m/s for CBTs were obtained by placing a round ROI (2-3 mm) on the stiffest region of the CBTs. Elasticity value was compared between hard and soft groups at manual palpation, benign and malignant groups and among three Shamblin types. The area under the receiver operating characteristic curve (AUC) analysis was performed to evaluate the performance of SWE in the malignancy prediction of CBTs. Sensitivity, specificity and accuracy were calculated. The cut-off value was obtained by using the Youden index. Results There were 19 benign CBTs and 3 malignant CBTs. Emax (kPa and m/s) and SDmax (kPa) were significantly higher in the hard group than in the soft group at manual palpation (P<0.05); The distribution of Emax in kPa and m/s and SDmax in kPa were different in the three Shamblin types (P<0.05), Emax (kPa and m/s)increased from shambling I to Shambling II and Shambling III; Emax (kPa and m/s) were significantly higher in the malignant CBTs than in the benign ones (P<0.05). Emax in kPa and m/s had the similar AUC value (AUC=0.947, P=1.0000) for the prediction of malignant CBTs. Emax in kPa with the cut-off 124.9kPa showed a sensitivity of 100.0%, specificity of 94.7%, and an accuracy of 95.5% (Z=8.500, P<0.0001); Emax in m/s with the cut-off 5.9m/s showed a sensitivity of 100.0%, specificity of 89.5% and an accuracy of 90.9% for the prediction of malignant CBTs (Z=9.143, P<0.0001). Conclusions Quantitative analysis of SWE obtained the good performance in the elasticity assessment of CBTs.
Collapse
Affiliation(s)
- Xiaoyan Zhang
- Department of Ultrasound, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yuehong Zheng
- Department of Vascular Surgery, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jianchu Li
- Department of Ultrasound, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China,*Correspondence: Jianchu Li, ; Bo Zhang,
| | - Bo Zhang
- Department of Ultrasound, China-Japan Friendship Hospital, Beijing, China,*Correspondence: Jianchu Li, ; Bo Zhang,
| |
Collapse
|
4
|
Qiaoer GBS, Nianyu XMS. Application and Progress of Ultrasound Technology in Atherosclerosis. ADVANCED ULTRASOUND IN DIAGNOSIS AND THERAPY 2023. [DOI: 10.37015/audt.2023.220030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023] Open
|
5
|
Muacevic A, Adler JR. Variability, Validity and Operator Reliability of Three Ultrasound Systems for Measuring Tissue Stiffness: A Phantom Study. Cureus 2022; 14:e31731. [PMCID: PMC9678015 DOI: 10.7759/cureus.31731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/21/2022] [Indexed: 11/23/2022] Open
Abstract
Introduction Ultrasound elastography is a method of measuring soft tissue stiffness to detect the presence of pathology. There are several ultrasound elastography devices on the market. The aim of this study was twofold. Firstly, to determine the validity of three different ultrasound systems used to measure tissue stiffness. Secondly, to determine the operator reliability and repeatability when using these three systems. Materials and methods Two observers undertook multiple stiffness measurements from a phantom model using three different ultrasound systems; the LOGIQ E9, the Aixplorer, and the Acuson S2000. The phantom model had four cylindrical-shaped inclusions (Type 1-4) of increasing stiffness values and diameter embedded within. The background phantom stiffness was fixed. The mean, standard deviation, and coefficient of variation (CV) were calculated from measured stiffness readings per diameter per inclusion. Intra-observer variability was assessed. The validity of the measured stiffness value was assessed by calculating the difference between the measured elasticities and actual phantom elasticities. Bland-Altman plots with limits of agreement were used to display the inter-observer agreement. The intraclass correlation coefficients (ICC) were used to measure intra-observer, inter-observer, and inter-system reliability. Results Each observer undertook 1020 measurements. All three systems generally underestimated the stiffness values for the inclusions; the higher the actual stiffness value, the more significant the underestimation. The percentage difference between measured stiffness and actual stiffness varied from -79.1% to 12.7%. The intra-observer variability was generally less than 5% for observers using the LOGIQ E9 and the Aixplorer systems but more than 10% over the stiffer inclusions (Types 3 and 4) for the Acuson system. There was 'almost perfect' intra-observer reliability and repeatability for both the LOGIQ E9 and the Aixplorer systems; this was 'moderate' for the Acuson system over specific inclusions. For all systems, there was 'almost perfect' inter-observer reliability and repeatability between Observer A and Observer B. The inter-system reliability and repeatability were 'almost perfect' between the LOGIQ E9 system and the Aixplorer system but 'poor' and 'moderate' when the Acuson system was matched with the LOGIQ E9 system and the Aixplorer system, respectively. Conclusion This study has demonstrated that the Acuson, LOGIQ E9, and Aixplorer ultrasound systems have low variability, high reproducibility, and good intra-observer and inter-observer reliability when used to measure tissue stiffness. However, they all underestimated the stiffness values during this in vitro study. This study also revealed that not all ultrasound systems are comparable when measuring tissue stiffness, with some having better inter-system reliability than others. Ongoing standardization of technology is required at the manufacturer level.
Collapse
|
6
|
Nordenfur T, Caidahl K, Grishenkov D, Maksuti E, Marlevi D, Urban MW, Larsson M. Safety of arterial shear wave elastography- ex-vivoassessment of induced strain and strain rates. Biomed Phys Eng Express 2022; 8. [PMID: 35797069 DOI: 10.1088/2057-1976/ac7f39] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 07/06/2022] [Indexed: 01/18/2023]
Abstract
Shear wave elastography (SWE) is a promising technique for characterizing carotid plaques and assessing local arterial stiffness. The mechanical stress to which the tissue is subjected during SWE using acoustic radiation force (ARF), leading to strain at a certain strain rate, is still relatively unknown. Because SWE is increasingly used for arterial applications where the mechanical stress could potentially lead to significant consequences, it is important to understand the risks of SWE- induced strain and strain rate. The aim of this study was to investigate the safety of SWE in terms of induced arterial strain and strain rateex-vivoand in a human carotid arteryin-vivo. SWE was performed on six porcine aortae as a model of the human carotid artery using different combinations of ARF push parameters (push voltage: 60/90 V, aperture width: f/1.0/1.5, push length: 100/150/200 μs) and distance to push position. The largest induced strain and strain rate were 1.46 % and 54 s-1(90 V, f/1.0, 200 μs), respectively. Moreover, the SWE-induced strains and strain rates increased with increasing push voltage, aperture, push length, and decreasing distance between the region of interest and the push. In the human carotid artery, the SWE-induced maximum strain was 0.06 % and the maximum strain rate was 1.58 s-1, compared with the maximum absolute strain and strain rate of 12.61 % and 5.12 s-1, respectively, induced by blood pressure variations in the cardiac cycle. Our results indicate thatex-vivoarterial SWE does not expose the artery to higher strain rate than normal blood pressure variations, and to strain one order of magnitude higher than normal blood pressure variations, at the push settings and distances from the region of interest used in this study.
Collapse
Affiliation(s)
- Tim Nordenfur
- Department of Biomedical Engineering and Health Systems, KTH, Kungliga Tekniska högskolan, Stockholm, 100 44, SWEDEN
| | - Kenneth Caidahl
- Department of Clinical Physiology, Karolinska University Hospital, Solnavägen 1, Solna, 171 77, SWEDEN
| | - Dmitry Grishenkov
- Department of Biomedical Engineering and Health Systems, KTH, KTH, Stockholm, 100 44, SWEDEN
| | - Elira Maksuti
- Dept. of Physiology and Pharmacology, Anaesthesiology and Intensive Care, Karolinska Institute, Solnavägen 1, Solna, 171 77, SWEDEN
| | - David Marlevi
- Dept. Molecular Medicine and Surgery, Karolinska Institute, Solnavägen 1, Solna, 171 77, SWEDEN
| | - Matthew W Urban
- Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, Minnesota, 55905, UNITED STATES
| | - Matilda Larsson
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, KTH, Stockholm, 100 44, SWEDEN
| |
Collapse
|
7
|
Alyami J, Almutairi F. Arterial Stiffness Assessment in Healthy Participants Using Shear Wave Elastography. Curr Med Imaging 2022; 18:1086-1092. [PMID: 35430974 DOI: 10.2174/1573405618666220415124535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Revised: 12/29/2021] [Accepted: 01/29/2022] [Indexed: 11/22/2022]
Abstract
BACKGROUND Arterial stiffness is an important biomarker for cardiovascular disease. Shear wave elastography (SWE) provides quantitative estimates of tissue stiffness. OBJECTIVE This study aimed to provide reference values for arterial wall, assessing the suitability of SWE to quantify elasticity of the common carotid artery (CCA) and evaluating inter- and intra-observer reproducibility. METHODS A Supersonic Aixplorer ultrasound system with L15-4 probe was used to scan longitudinal sections of the CCA. Young's modulus (YM) was measured within 2-mm regions of interest. Reproducibility was assessed within a subgroup of 16 participants by two operators (one novice and one experienced) during two sessions >one week apart. RESULTS This study involves seventy-three participants with a mean age of 40±10 years and body mass index of 26 ±6 kg/m2. YM estimates were 59 kPa ±19 in men and 56 kPa ±12 in women. The average YM of the CCA walls was 58 kPa ±15 (57 ±15 kPa for the anterior wall and 58 ±20 kPa for the posterior wall, p=0.75). There was no significant difference in the mean of YM estimates of the CCA between the observers (observer: one 51 ±14 kPa and observer two: 55 ±17 kPa [p=0.46]). inter- and intra-observer reproducibility was fair to good (Intra-class correlations, ranging from 0.46 to 0.71). Inter-frame variability was 28%. CONCLUSION In healthy individuals, SWE provided an estimate of YM of the CCA (58 kPa) with fair to good reproducibility. This study demonstrated the potential of using SWE for assessing biomechanical properties of blood vessels.
Collapse
Affiliation(s)
- Jaber Alyami
- Department of Diagnostic Radiology, Faculty of Applied Medical Science, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Fahad Almutairi
- Department of Diagnostic Radiology, Faculty of Applied Medical Science, King Abdulaziz University, Jeddah, Saudi Arabia
| |
Collapse
|
8
|
Golemati S, Cokkinos DD. Recent advances in vascular ultrasound imaging technology and their clinical implications. ULTRASONICS 2022; 119:106599. [PMID: 34624584 DOI: 10.1016/j.ultras.2021.106599] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Revised: 08/26/2021] [Accepted: 09/21/2021] [Indexed: 06/13/2023]
Abstract
In this paper recent advances in vascular ultrasound imaging technology are discussed, including three-dimensional ultrasound (3DUS), contrast-enhanced ultrasound (CEUS) and strain- (SE) and shear-wave-elastography (SWE). 3DUS imaging allows visualisation of the actual 3D anatomy and more recently of flow, and assessment of geometrical, morphological and mechanical features in the carotid artery and the aorta. CEUS involves the use of microbubble contrast agents to estimate sensitive blood flow and neovascularisation (formation of new microvessels). Recent developments include the implementation of computerised tools for automated analysis and quantification of CEUS images, and the possibility to measure blood flow velocity in the aorta. SE, which yields anatomical maps of tissue strain, is increasingly being used to investigate the vulnerability of the carotid plaque, but is also promising for the coronary artery and the aorta. SWE relies on the generation of a shear wave by remote acoustic palpation and its acquisition by ultrafast imaging, and is useful for measuring arterial stiffness. Such advances in vascular ultrasound technology, with appropriate validation in clinical trials, could positively change current management of patients with vascular disease, and improve stratification of cardiovascular risk.
Collapse
Affiliation(s)
- Spyretta Golemati
- Medical School, National and Kapodistrian University of Athens, Athens, Greece.
| | | |
Collapse
|
9
|
Al-Mutairi FF, Al-Hussaini A, Marsh AM, Samani N, McCann G, Adlam D, Chung EML, Ramnarine KV. Ultrasound shear wave elastography imaging of common carotid arteries in patients with Spontaneous Coronary Artery Dissection (SCAD). J Ultrasound 2022; 25:585-589. [PMID: 35032295 PMCID: PMC9402834 DOI: 10.1007/s40477-021-00627-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Accepted: 09/18/2021] [Indexed: 10/26/2022] Open
Abstract
BACKGROUND Shear wave elastography (SWE) is emerging as a valuable clinical tool for a variety of conditions. The aim of this pilot study was to assess the potential of SWE imaging of the common carotid arteries (CCA) in patients with spontaneous coronary artery dissection (SCAD), a rare but potentially life-threatening condition, hypothesized to be linked to changes in vessel wall elasticity. METHODS Ultrasound shear wave elastography (SWE) estimates of artery wall elasticity were obtained from the left and right CCAs of 89 confirmed SCAD patients and 38 non-dissection controls. SWE images obtained over multiple cardiac cycles were analysed by a blinded observer to estimate elasticity in the form of a Young's Modulus (YM) value, across regions of interest (ROI) located within the anterior and posterior CCA walls. RESULTS YM estimates ranged from 17 to 133 kPa in SCAD patients compared to 34 to 87 kPa in non-dissection controls. The mean YM of 55 [standard deviation (SD): 21] kPa in SCAD patients was not significantly different to the mean of 57 [SD: 12] kPa in controls, p = 0.32. The difference between groups was 2 kPa [95% Confidence Interval - 11, 4]. CONCLUSIONS SWE imaging of CCAs in SCAD patients is feasible although the clinical benefit is limited by relatively high variability of YM values which may have contributed to our finding of no significant difference between SCAD patients and non-dissection controls.
Collapse
Affiliation(s)
- Fahad F Al-Mutairi
- Department of Diagnostic Radiology, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia. .,Department of Cardiovascular Sciences, University of Leicester, Leicester, UK.
| | - Abtehal Al-Hussaini
- National Institute for Health Research (NIHR) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK
| | - Anne-Marie Marsh
- National Institute for Health Research (NIHR) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK
| | - Nilesh Samani
- Department of Cardiovascular Sciences, University of Leicester, Leicester, UK.,National Institute for Health Research (NIHR) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK
| | - Gerry McCann
- Department of Cardiovascular Sciences, University of Leicester, Leicester, UK.,National Institute for Health Research (NIHR) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK
| | - David Adlam
- Department of Cardiovascular Sciences, University of Leicester, Leicester, UK.,National Institute for Health Research (NIHR) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK
| | - Emma M L Chung
- Department of Cardiovascular Sciences, University of Leicester, Leicester, UK.,National Institute for Health Research (NIHR) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK.,Department of Medical Physics, University Hospitals of Leicester NHS Trust, Leicester, UK
| | - Kumar V Ramnarine
- Department of Cardiovascular Sciences, University of Leicester, Leicester, UK.,Department of Medical Physics, University Hospitals of Leicester NHS Trust, Leicester, UK.,Medical Physics Department, Guy's and St Thomas' NHS Foundation Trust, London, UK
| |
Collapse
|
10
|
Al-Mutairi FF, Chung EM, Moran CM, Ramnarine KV. A Novel Elastography Phantom Prototype for Assessment of Ultrasound Elastography Imaging Performance. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2749-2758. [PMID: 34144833 DOI: 10.1016/j.ultrasmedbio.2021.05.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 05/08/2021] [Accepted: 05/17/2021] [Indexed: 06/12/2023]
Abstract
The aims of this study were firstly to manufacture and evaluate a novel elastography test phantom and secondly to assess the performance of an elastography system using this phantom. A novel Leicester-St. Thomas' Elastography Pipe (L-STEP) test phantom consisting of five soft polyvinyl acrylic-cryogel pipes of varying diameters (2-12 mm), embedded at 45° within an agar-based tissue-mimicking material was developed. A shear-wave elastography (SWE) scanner was used by two blinded operators to image and assess longitudinal sections of the pipes. Young's modulus estimates were dependent on the diameter of pipes and at superficial depths were greater than deeper depths (mean 98 kPa vs. 59 kPa) and had lower coefficients of variation (mean 21% vs. 53%). The penetration depth (maximum depth at which a SWE signal was obtained) increased with increasing pipe diameter. Penetration depth measurements had excellent inter- and intra-operator reproducibility (intra-class correlation coefficients >0.8) and coefficient of variation range of 2%-12%. A new metric, called the summative performance index, was defined as the sum of the ratios of the penetration depth/pipe diameter. The L-STEP phantom is suitable for assessing key aspects of elastography imaging performance: resolution, accuracy, reproducibility, depth dependence, sensitivity and our novel summative performance index.
Collapse
Affiliation(s)
- Fahad F Al-Mutairi
- Department of Diagnostic Radiology, Faculty of Applied Medical Sciences, King Abdulaziz University (KAU), Jeddah, Saudi Arabia; Department of Cardiovascular Sciences, University of Leicester, Leicester, United Kingdom
| | - Emma Ml Chung
- Department of Cardiovascular Sciences, University of Leicester, Leicester, United Kingdom; National Institute for Health Research (NIHR) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, United Kingdom; Department of Medical Physics, University Hospitals of Leicester NHS Trust, Leicester, United Kingdom
| | - Carmel M Moran
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
| | - Kumar V Ramnarine
- Department of Cardiovascular Sciences, University of Leicester, Leicester, United Kingdom; Medical Physics Department, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom.
| |
Collapse
|
11
|
Zhang Y, Cao J, Zhou J, Zhang C, Li Q, Chen S, Feinstein S, Grayburn PA, Huang P. Plaque Elasticity and Intraplaque Neovascularisation on Carotid Artery Ultrasound: A Comparative Histological Study. Eur J Vasc Endovasc Surg 2021; 62:358-366. [PMID: 34266763 DOI: 10.1016/j.ejvs.2021.05.026] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2019] [Revised: 05/12/2021] [Accepted: 05/23/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVE Plaque elasticity and intraplaque neovascularisation are strongly suggestive of vulnerable plaque. This study aimed to investigate the relationship between intraplaque neovascularisation and plaque elasticity, and to compare the ultrasound findings with histopathological changes. METHODS Patients enrolled in this study presented with symptomatic carotid stenosis (> 70%) and later underwent both pre-operative ultrasonography and endarterectomy. Contrast enhanced ultrasound (CEUS) and shear wave elastography (SWE) were used to measure the neovascularisation and elasticity of the plaque, respectively. After removal, plaques were histologically assessed to determine the microvessel density (MVD), matrix metalloproteinase (MMP)-9 expression, and type I/type III collagen ratio using immunohistochemistry staining and morphometry. A correlation analysis was used to establish the relationship among the aforementioned quantitative parameters. Inter- and intra-observer consistency evaluations were performed using the intraclass correlation coefficient and Bland-Altman plots. RESULTS Ninety-four symptomatic patients with 98 plaques were included. The area under the curve (AUC) of the carotid plaque detected using CEUS correlated with its shear wave velocity (SWV) (r = -.714; p < .001), MVD (r = .842; p < .001), collagen type I/III ratio (r = -.833; p < .001), and MMP-9 (r = .738; p < .001). SWE was positively correlated with the type I/III collagen ratio (r = .805; p < .001). The overall interexaminer consistency of the SWE was acceptable (r = .638; p < .001). The interobserver correlation coefficient of the AUC, time to peak (TP), mean transit time (MTT), and SWV were .719, .756, .733, and .686, respectively. The intra-observer variability values of the AUC, TP, MTT, and SWV were .826, .845, .633, and .748, respectively. CONCLUSION SWE and CEUS can comprehensively evaluate the vulnerability of the carotid plaque by assessing the elasticity of the plaque and neovascularisation within it. The negative correlation between the intraplaque neovascularisation and elasticity, further validated by histological findings, suggests that the more abundant the neovascularisation, the less elasticity.
Collapse
Affiliation(s)
- Ying Zhang
- Department of Ultrasound in Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine, Zhejiang, China
| | - Jing Cao
- Department of Ultrasound in Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine, Zhejiang, China
| | - Jingyi Zhou
- Department of Neurosurgery, Second Affiliated Hospital of Zhejiang University School of Medicine, Zhejiang, China
| | - Chao Zhang
- Department of Ultrasound in Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine, Zhejiang, China
| | - Qunying Li
- Department of Ultrasound in Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine, Zhejiang, China
| | - Shuyuan Chen
- Baylor Scott & White Research Institute, Dallas, TX, USA
| | - Steven Feinstein
- Echocardiography Section of Cardiology, Rush University Medical Centre, Chicago, IL, USA
| | - Paul A Grayburn
- Department of Internal Medicine, Division of Cardiology, Baylor Scott & White Heart and Vascular Institute, Baylor University Medical Centre, Dallas, TX, USA
| | - Pintong Huang
- Department of Ultrasound in Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine, Zhejiang, China.
| |
Collapse
|
12
|
Školoudík D, Kešnerová P, Vomáčka J, Hrbáč T, Netuka D, Forostyak S, Roubec M, Herzig R, Belšan T. Shear-Wave Elastography Enables Identification of Unstable Carotid Plaque. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:1704-1710. [PMID: 33931284 DOI: 10.1016/j.ultrasmedbio.2021.03.026] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 03/13/2021] [Accepted: 03/23/2021] [Indexed: 06/12/2023]
Abstract
Shear-wave elastography (SWE) is a novel ultrasound technique for quantifying tissue elasticity. The aim of this study was to identify differences in atherosclerotic plaque elasticity measured using SWE among individuals with symptomatic, asymptomatic progressive and asymptomatic stable carotid plaques. Consecutive patients from the Atherosclerotic Plaque Characteristics Associated with a Progression Rate of the Plaque and a Risk of Stroke in Patients with the Carotid Bifurcation Plaque Study were screened for this research. Neurosonography examination of carotid arteries was performed to identify plaque stenosis of ≥50% using B-mode ultrasound and SWE imaging to measure the mean, maximal and minimal elasticity. The set consisted of 97 participants-74 with asymptomatic stable stenosis, 12 with asymptomatic progressive stenosis and 11 with symptomatic stenosis. The mean elasticity in the asymptomatic stable plaque group was significantly higher than in the asymptomatic progressive (52.2 vs. 30.4 kPa; p < 0.001) and symptomatic (52.2 vs. 36.4 kPa; p = 0.033) plaque groups. No significant differences were found between asymptomatic progressive and symptomatic (p > 0.1) plaque groups. Asymptomatic stable, asymptomatic progressive and symptomatic plaques did not differ in echogenicity, calcifications, homogeneity, occurrence of ulcerated surface, or intra-plaque hemorrhage (p > 0.05 in all cases). SWE was a helpful modality for differentiating between stable and unstable atherosclerotic plaques in carotid arteries.
Collapse
Affiliation(s)
- David Školoudík
- Center for Health Research, Ostrava University Medical Faculty, Ostrava, Czech Republic; Stroke Center, Vítkovice Hospital, Ostrava, Czech Republic; Comprehensive Stroke Center, Department of Neurosurgery, University Hospital Ostrava, Ostrava, Czech Republic; Faculty of Health Sciences, Palacký University Olomouc, Olomouc, Czech Republic.
| | - Petra Kešnerová
- Comprehensive Stroke Center, 2(nd) Medical Faculty, Charles University Prague and University Hospital Motol, Prague, Czech Republic
| | - Jaroslav Vomáčka
- Faculty of Health Sciences, Palacký University Olomouc, Olomouc, Czech Republic
| | - Tomáš Hrbáč
- Comprehensive Stroke Center, Department of Neurosurgery, University Hospital Ostrava, Ostrava, Czech Republic
| | - David Netuka
- Comprehensive Stroke Center, Department of Neurosurgery, Military Teaching Hospital Prague, Prague, Czech Republic
| | | | - Martin Roubec
- Comprehensive Stroke Center, Department of Neurology, University Hospital Ostrava, Ostrava, Czech Republic
| | - Roman Herzig
- Department of Neurology, Comprehensive Stroke Center, Charles University Faculty of Medicine and University Hospital Hradec Králové, Hradec Králové, Czech Republic
| | - Tomáš Belšan
- Comprehensive Stroke Center, Department of Radiology, Military Teaching Hospital Prague, Prague, Czech Republic
| |
Collapse
|
13
|
Li Y, Zheng S, Zhang J, Wang F, Liu X, He W. Advance ultrasound techniques for the assessment of plaque vulnerability in symptomatic and asymptomatic carotid stenosis: a multimodal ultrasound study. Cardiovasc Diagn Ther 2021; 11:28-38. [PMID: 33708475 DOI: 10.21037/cdt-20-876] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Background Advanced carotid ultrasound techniques may be useful in characterizing plaque vulnerability, but comprehensive studies are still lacking. The aim of this study was to identify factors associated with vulnerable plaques using advanced ultrasound techniques. Methods This is a prospective observational study of patients with >50% internal carotid stenosis (ICA). All patients underwent conventional ultrasound, superb microvascular imaging (SMI) and shear wave elastography (SWE) examinations. Plaque size, echogenicity, stiffness and intraplaque neovascularization (IPN) were assessed and compared between symptomatic and asymptomatic groups. Receiver operating characteristic (ROC) curves were used to evaluate the diagnostic performance of SWE and SMI of the vulnerable plaques. Results The final analysis included 123 patients (78.9% male; mean age, 66±8 years), 65 were enrolled in the symptomatic group, and 58 were enrolled in the asymptomatic group. The mean elasticity was 78.1±25.4 kPa for asymptomatic and 51.5±18.3 kPa for symptomatic plaques. Symptomatic plaques showed higher visual IPN grades on SMI than asymptomatic plaques (P<0.001). Multivariate regression analysis showed that plaque stiffness (PS) (OR 0.95, 95% CI, 0.919-0.974) and IPN level (OR 4.17, 95% CI, 2.008-8.664) were independently associated with symptomatic plaques. The combination of the two factors had a preferable accuracy to discriminate symptomatic plaques (AUC 0.89, 95% CI, 0.827-0.944). Conclusions Advanced carotid ultrasound techniques can identify plaque characteristics that are associated with ischemic events and may be potentially indicative of plaque vulnerability. These factors may ultimately be used in the clinical management of carotid stenosis.
Collapse
Affiliation(s)
- Yi Li
- Department of Ultrasound, Capital Medical University, Beijing, China.,Department of Ultrasound, Beijing Tiantan Hospital, Beijing, China
| | - Shuai Zheng
- Department of Ultrasound, Capital Medical University, Beijing, China.,Department of Ultrasound, Beijing Tiantan Hospital, Beijing, China
| | - Jinghan Zhang
- Department of Ultrasound, Capital Medical University, Beijing, China.,Department of Ultrasound, Beijing Tiantan Hospital, Beijing, China
| | - Fumin Wang
- Department of Ultrasound, Capital Medical University, Beijing, China.,Department of Ultrasound, Beijing Tiantan Hospital, Beijing, China
| | - Xinyao Liu
- Department of Ultrasound, Capital Medical University, Beijing, China.,Department of Ultrasound, Beijing Tiantan Hospital, Beijing, China
| | - Wen He
- Department of Ultrasound, Capital Medical University, Beijing, China.,Department of Ultrasound, Beijing Tiantan Hospital, Beijing, China
| |
Collapse
|
14
|
Ambrogio S, Baêsso RDM, Gomis A, Rivens I, Haar GT, Zeqiri B, Ramnarine KV, Fedele F, Miloro P. A Polyvinyl Alcohol-Based Thermochromic Material for Ultrasound Therapy Phantoms. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:3135-3144. [PMID: 32873445 DOI: 10.1016/j.ultrasmedbio.2020.07.032] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 07/27/2020] [Accepted: 07/31/2020] [Indexed: 06/11/2023]
Abstract
Temperature estimation is a fundamental step in assessment of the efficacy of thermal therapy. A thermochromic material sensitive within the temperature range 52.5°C-75°C has been developed. The material is based on polyvinyl alcohol cryogel with the addition of a commercial thermochromic ink. It is simple to manufacture, low cost, non-toxic and versatile. The thermal response of the material was evaluated using multiple methods, including immersion in a temperature-controlled water bath, a temperature-controlled heated needle and high-intensity focused ultrasound (HIFU) sonication. Changes in colour were evaluated using both RGB (red, green, blue) maps and pixel intensities. Acoustic and thermal properties of the material were measured. Thermo-acoustic simulations were run with an open-source software, and results were compared with the HIFU experiments, showing good agreement. The material has good potential for the development of ultrasound therapy phantoms.
Collapse
Affiliation(s)
- Simone Ambrogio
- Medical Physics Department, Guy's & St Thomas' NHS Foundation Trust, London, United Kingdom; Ultrasound and Underwater Acoustics, National Physical Laboratory, Hampton Road, Teddington, United Kingdom.
| | - Raphaela de Melo Baêsso
- Ultrasound and Underwater Acoustics, National Physical Laboratory, Hampton Road, Teddington, United Kingdom
| | - Alberto Gomis
- Ultrasound and Underwater Acoustics, National Physical Laboratory, Hampton Road, Teddington, United Kingdom; Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Ian Rivens
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Gail Ter Haar
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Bajram Zeqiri
- Ultrasound and Underwater Acoustics, National Physical Laboratory, Hampton Road, Teddington, United Kingdom
| | - Kumar V Ramnarine
- Medical Physics Department, Guy's & St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Fiammetta Fedele
- Medical Physics Department, Guy's & St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Piero Miloro
- Ultrasound and Underwater Acoustics, National Physical Laboratory, Hampton Road, Teddington, United Kingdom
| |
Collapse
|
15
|
Pruijssen JT, de Korte CL, Voss I, Hansen HHG. Vascular Shear Wave Elastography in Atherosclerotic Arteries: A Systematic Review. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:2145-2163. [PMID: 32620385 DOI: 10.1016/j.ultrasmedbio.2020.05.013] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 05/15/2020] [Accepted: 05/15/2020] [Indexed: 06/11/2023]
Abstract
Ischemic stroke is a leading cause of death and disability worldwide, so adequate prevention strategies are crucial. However, current stroke risk stratification is based on epidemiologic studies and is still suboptimal for individual patients. The aim of this systematic review was to provide a literature overview on the feasibility and diagnostic value of vascular shear wave elastography (SWE) using ultrasound (US) in (mimicked) human and non-human arteries affected by different stages of atherosclerotic diseases or diseases related to atherosclerosis. An online search was conducted on Pubmed, Embase, Web of Science and IEEE databases to identify studies using US SWE for the assessment of vascular elasticity. A quality assessment was performed using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) checklist, and relevant data were extracted. A total of 19 studies were included: 10 with human patients and 9 with non-human subjects (i.e., [excised] animal arteries and polyvinyl alcohol phantoms). All studies revealed the feasibility of using US SWE to assess individually stiffness of the arterial wall and plaques. Quantitative elasticity values were highly variable between studies. However, within studies, SWE could detect statistically significant elasticity differences in patient/subject characteristics and could distinguish different plaque types with good reproducibility. US SWE, with its unique ability to assess the elasticity of the vessel wall and plaque throughout the cardiac cycle, might be a good candidate to improve stroke risk stratification. However, more clinical studies have to be performed to assess this technique's exact clinical value.
Collapse
Affiliation(s)
- Judith T Pruijssen
- Medical Ultrasound Imaging Centre (MUSIC), Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands.
| | - Chris L de Korte
- Medical Ultrasound Imaging Centre (MUSIC), Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands; Physics of Fluid Group, MESA+ Institute for Nanotechnology, and MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands
| | - Iona Voss
- Medical Ultrasound Imaging Centre (MUSIC), Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Hendrik H G Hansen
- Medical Ultrasound Imaging Centre (MUSIC), Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| |
Collapse
|
16
|
Receive/Transmit Aperture Selection for 3D Ultrasound Imaging with a 2D Matrix Transducer. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10155300] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Recently, we realized a prototype matrix transducer consisting of 48 rows of 80 elements on top of a tiled set of Application Specific Integrated Circuits (ASICs) implementing a row-level control connecting one transmit/receive channel to an arbitrary subset of elements per row. A fully sampled array data acquisition is implemented by a column-by-column (CBC) imaging scheme (80 transmit-receive shots) which achieves 250 volumes/second (V/s) at a pulse repetition frequency of 20 kHz. However, for several clinical applications such as carotid pulse wave imaging (CPWI), a volume rate of 1000 per second is needed. This allows only 20 transmit-receive shots per 3D image. In this study, we propose a shifting aperture scheme and investigate the effects of receive/transmit aperture size and aperture shifting step in the elevation direction. The row-level circuit is used to interconnect elements of a receive aperture in the elevation (row) direction. An angular weighting method is used to suppress the grating lobes caused by the enlargement of the effective elevation pitch of the array, as a result of element interconnection in the elevation direction. The effective aperture size, level of grating lobes, and resolution/sidelobes are used to select suitable reception/transmission parameters. Based on our assessment, the proposed imaging sequence is a full transmission (all 80 elements excited at the same time), a receive aperture size of 5 and an aperture shifting step of 3. Numerical results obtained at depths of 10, 15, and 20 mm show that, compared to the fully sampled array, the 1000 V/s is achieved at the expense of, on average, about two times wider point spread function and 4 dB higher clutter level. The resulting grating lobes were at −27 dB. The proposed imaging sequence can be used for carotid pulse wave imaging to generate an informative 3D arterial stiffness map, for cardiovascular disease assessment.
Collapse
|
17
|
Otesteanu CF, Chintada BR, Rominger MB, Sanabria SJ, Goksel O. Spectral Quantification of Nonlinear Elasticity Using Acoustoelasticity and Shear-Wave Dispersion. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:1845-1855. [PMID: 31398118 DOI: 10.1109/tuffc.2019.2933952] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Tissue biomechanical properties are known to be sensitive to pathological changes. Accordingly, various techniques have been developed to estimate tissue mechanical properties. Shear-wave elastography (SWE) measures shear-wave speed (SWS) in tissues, which can be related to shear modulus. Although viscosity or stress-strain nonlinearity may act as confounder of SWE, their explicit characterization may also provide additional information about tissue composition as a contrast modality. Viscosity can be related to frequency dispersion of SWS, which can be characterized using multi-frequency measurements, herein called spectral SWE (SSWE). Additionally, nonlinear shear modulus can be quantified and parameterized based on SWS changes with respect to applied stress, a phenomenon called acoustoelasticity (AE). In this work, we characterize the nonlinear parameters of tissue as a function of excitation frequency by utilizing both AE and SSWE together. For this, we apply incremental amounts of quasi-static stress on a medium, while imaging and quantifying SWS dispersion via SSWE. Results from phantom and ex vivo porcine liver experiments demonstrate the feasibility of measuring frequency-dependent nonlinear parameters using the proposed method. SWS propagation in porcine liver tissue was observed to change from 1.8 m/s at 100 Hz to 3.3 m/s at 700 Hz, while increasing by approximately 25% from a strain of 0% to 12% across these frequencies.
Collapse
|
18
|
Chayer B, van den Hoven M, Cardinal MHR, Li H, Swillens A, Lopata R, Cloutier G. Atherosclerotic carotid bifurcation phantoms with stenotic soft inclusions for ultrasound flow and vessel wall elastography imaging. ACTA ACUST UNITED AC 2019; 64:095025. [DOI: 10.1088/1361-6560/ab1145] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
19
|
Liu Z, Bai Z, Huang C, Huang M, Huang L, Xu D, Zhang H, Yuan C, Luo J. Interoperator Reproducibility of Carotid Elastography for Identification of Vulnerable Atherosclerotic Plaques. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:505-516. [PMID: 30575532 DOI: 10.1109/tuffc.2018.2888479] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Ultrasound-based carotid elastography has been developed to evaluate the vulnerability of carotid atherosclerotic plaques. The aim of this study was to investigate the in vivo interoperator reproducibility of carotid elastography for the identification of vulnerable plaques, with high-resolution magnetic resonance imaging (MRI) as reference. Ultrasound radio-frequency data of 45 carotid arteries (including 53 plaques) from 32 volunteers were acquired separately by two experienced operators in the longitudinal view and then were used to estimate the interframe axial strain rate (ASR) with a two-step optical flow method. The maximum 99th percentile of absolute ASR of all plaques in a carotid artery was used as the elastographic index. MRI scanning was also performed on each volunteer to identify the vulnerable plaque. The results showed no systematic bias in the Bland-Altman plot and an intraclass correlation coefficient of 0.66 between the two operators. In addition, no statistical significance was found between the receiver operating characteristic (ROC) curves from the two operators ( ), and their areas under the ROC curves were 0.83 and 0.77, respectively. Using the mean measurements of the two operators as the classification criterion, a sensitivity of 71.4%, a specificity of 87.1%, and an accuracy of 82.2% were obtained with a cutoff value of 1.37 [Formula: see text]. This study validates the interoperator reproducibility of ultrasound-based carotid elastography for identifying vulnerable carotid plaques.
Collapse
|
20
|
Sivasankar R, Singh R, Hashim PI, Soni B, Patel R, Bajpai A. Evaluation of carotid plaque vulnerability using shear-wave elastography: An observational comparative study. JOURNAL OF MARINE MEDICAL SOCIETY 2019. [DOI: 10.4103/jmms.jmms_31_19] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
21
|
Marlevi D, Maksuti E, Urban MW, Winter R, Larsson M. Plaque characterization using shear wave elastography—evaluation of differentiability and accuracy using a combined ex vivo and in vitro setup. ACTA ACUST UNITED AC 2018; 63:235008. [DOI: 10.1088/1361-6560/aaec2b] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
22
|
Shih CC, Qian X, Ma T, Han Z, Huang CC, Zhou Q, Shung KK. Quantitative Assessment of Thin-Layer Tissue Viscoelastic Properties Using Ultrasonic Micro-Elastography With Lamb Wave Model. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:1887-1898. [PMID: 29993652 DOI: 10.1109/tmi.2018.2820157] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Characterizing the viscoelastic properties of thin-layer tissues with micro-level thickness has long remained challenging. Recently, several micro-elastography techniques have been developed to improve the spatial resolution. However, most of these techniques have not considered the medium boundary conditions when evaluating the viscoelastic properties of thin-layer tissues such as arteries and corneas; this might lead to estimation bias or errors. This paper aims to integrate the Lamb wave model with our previously developed ultrasonic micro-elastography imaging system for obtaining accurate viscoelastic properties in thin-layer tissues. A 4.5-MHz ring transducer was used to generate an acoustic radiation force for inducing tissue displacements to produce guided wave, and the wave propagation was detected using a confocally aligned 40-MHz needle transducer. The phase velocity and attenuation were obtained from k-space by both the impulse and the harmonic methods. The measured phase velocity was fit using the Lamb wave model with the Kelvin-Voigt model. Phantom experiments were conducted using 7% and 12% gelatin and 1.5% agar phantoms with different thicknesses (2, 3, and 4 mm). Biological experiments were performed on porcine cornea and rabbit carotid artery ex vivo. Thin-layer phantoms with different thicknesses were confirmed to have the same elasticity; this was consistent with the estimates of bulk phantoms from mechanical tests and the shear wave rheological model. The trend of the measured attenuations was also confirmed with the viscosity results obtained using the Lamb wave model. Through the impulse and harmonic methods, the shear viscoelasticity values were estimated to be 8.2 kPa for $0.9~\text {Pa}{\cdot} \text {s}$ and 9.6 kPa for $0.8~\text {Pa}{\cdot} \text {s}$ in the cornea and 27.9 kPa for $0.1~\text {Pa}\cdot \text {s}$ and 26.5 kPa for $0.1~\text {Pa}\cdot \text {s}$ in the artery.
Collapse
|
23
|
Gülşen F, Samanci C, Memis Durmaz ES, Durmaz E, Tel C, Gencturk M, Ağırman A. Brachial Artery Wall Stiffness Assessment by Shear Wave Elastography: A Promising New Diagnostic Tool for Endothelial Dysfunction Detection. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2018; 37:1977-1983. [PMID: 29363817 DOI: 10.1002/jum.14548] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2017] [Revised: 10/21/2017] [Accepted: 10/30/2017] [Indexed: 06/07/2023]
Abstract
OBJECTIVES This study was designed to measure the changes in brachial artery wall stiffness by shear wave elastography (SWE) and evaluate the accuracy of SWE changes for detection of endothelial dysfunction. METHODS Sixty-five consecutive participants (19 patients with atherosclerosis proven by coronary angiography, 16 healthy young adults, 15 patients with cardiovascular risk factors, and 15 healthy older adults between 50 and 60 years) were prospectively included in this study. They were examined in the same week by SWE, and flow-mediated dilatation was evaluated for each patient. RESULTS The mean flow-mediated dilatation values ± 2 SDs after forearm occlusion were 8.54% ± 1.4% in healthy young adults, 7.61% ± 1.4% in healthy older adults, 5.83% ± 0.7% in patients with risk factors (P < .001), and 3.81% ± 2.4% in patients with atherosclerosis (P < .001, with respect to the risk factor group). There was a significant decrease in stiffness measurements in parallel with the increase in flow-mediated dilatation: 19.9% ± 6.3% in healthy young adults, 16.3% ± 5.1% in healthy older adults, 9.8% ± 5.4% in patients with risk factors (P < .05 with respect to the group with no risk factors), and 7.8% ± 6.4% in patients with atherosclerosis (P < .001 with respect to the healthy older adults). CONCLUSIONS Shear wave elastography in combination with flow-mediated dilatation could be a promising, widely available noninvasive diagnostic tool for detecting endothelial dysfunction.
Collapse
Affiliation(s)
- Fatih Gülşen
- Departments of Radiology, Istanbul University, Cerrahpasa Faculty of Medicine, Istanbul, Turkey
| | - Cesur Samanci
- Departments of Radiology, Istanbul University, Cerrahpasa Faculty of Medicine, Istanbul, Turkey
| | | | - Eser Durmaz
- Departments of Cardiology, Istanbul University, Cerrahpasa Faculty of Medicine, Istanbul, Turkey
| | - Cigdem Tel
- Departments of Cardiovascular surgery, Istanbul University, Cerrahpasa Faculty of Medicine, Istanbul, Turkey
| | - Mert Gencturk
- Department of Radiology, Yedikule Surp Pırgiç Armenian Hospital, Istanbul, Turkey
| | - Aysegul Ağırman
- Department of Radiology, Yedikule Surp Pırgiç Armenian Hospital, Istanbul, Turkey
| |
Collapse
|
24
|
Shang J, Wang W, Feng J, Luo GG, Dang Y, Sun J, Yang YQ, Ruan LT. Carotid Plaque Stiffness Measured with Supersonic Shear Imaging and Its Correlation with Serum Homocysteine Level in Ischemic Stroke Patients. Korean J Radiol 2018; 19:15-22. [PMID: 29353995 PMCID: PMC5768496 DOI: 10.3348/kjr.2018.19.1.15] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2016] [Accepted: 12/24/2016] [Indexed: 11/15/2022] Open
Abstract
Objective To ascertain the feasibility of using shear wave velocity (SWV) in assessing the stiffness of carotid plaque by supersonic shear imaging (SSI) and explore preliminary clinical value for such evaluation. Materials and Methods Supersonic shear imaging was performed in 142 patients with ischemic stroke, including 76 males and 66 females with mean age of 66 years (range, 45-80 years). The maximum, minimum, and mean values of SWV were measured for 129 carotid plaques. SWVs were compared between echolucent and echogenic plaques. Correlations between SWVs and serum homocysteine levels were investigated. Based on neurological symptom, the surrogate marker of vulnerable plaque (VP), binary logistic regression was performed and area under curve (AUC) of homocysteine only and homocysteine combing SWVmean was calculated respectively. Results Echogenic plaques (n = 51) had higher SWVs than echolucent ones (n = 78) (SWVmin 3.91 [3.24-4.17] m/s vs. 1.51 [1.04-1.94] m/s; SWVmean, 4.29 [3.98-4.57] m/s vs. 2.09 [1.69-2.41] m/s; SWVmax, 4.67 [4.33-4.86] m/s vs. 2.62 [2.32-3.31] m/s all p values < 0.01). Pearson correlation analysis showed that stiffness of plaques was negatively correlated with homocysteine level. R values for SWVmin, SWVmean, and SWVmax were -0.205, -0.213, and -0.199, respectively. Binary logistic regression analysis showed that sex (p = 0.008), low-density lipoprotein (p = 0.015), triglycerides (p = 0.011), SWVmean (p = 0.004), and hyper-homocysteinemia (p = 0.010) were significantly associated with symptomatic ischemic stroke. Receiver operating characteristic curves revealed that SWVmean combing serum homocysteine level (AUC = 0.67) presented better diagnostic value than serum homocysteine only (AUC = 0.60) for symptomatic ischemic stroke. Conclusion Supersonic shear imaging could be used to quantitatively evaluate stiffness of both echolucent and echogenic carotid plaques. More importantly, SWVs of plaques were not only correlated to serum homocysteine level, but also associated with symptomatic ischemic stroke, suggesting that SSI might be useful for understanding more about VP.
Collapse
Affiliation(s)
- Jing Shang
- Department of Ultrasound Medicine, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China
| | - Wen Wang
- Department of Radiology, Tangdu Hospital, Fourth Military Medical University, Xi'an 710038, China
| | - Jun Feng
- Department of Neurology, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China
| | - Guo-Gang Luo
- Department of Neurology, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China
| | - Ying Dang
- Department of Ultrasound Medicine, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China
| | - Jian Sun
- Department of Ultrasound Medicine, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China
| | - Yan-Qiu Yang
- Department of Ultrasound Medicine, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China
| | - Li-Tao Ruan
- Department of Ultrasound Medicine, The First Affiliated Hospital, Xi'an Jiaotong University, Xi'an 710061, China
| |
Collapse
|
25
|
Poree J, Chayer B, Soulez G, Ohayon J, Cloutier G. Noninvasive Vascular Modulography Method for Imaging the Local Elasticity of Atherosclerotic Plaques: Simulation and In Vitro Vessel Phantom Study. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:1805-1817. [PMID: 28961110 DOI: 10.1109/tuffc.2017.2757763] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Mechanical and morphological characterization of atherosclerotic lesions in carotid arteries remains an essential step for the evaluation of rupture prone plaques and the prevention of strokes. In this paper, we propose a noninvasive vascular imaging modulography (NIV-iMod) method, which is capable of reconstructing a heterogeneous Young's modulus distribution of a carotid plaque from the Von Mises strain elastogram. Elastograms were computed with noninvasive ultrasound images using the Lagrangian speckle model estimator and a dynamic segmentation-optimization procedure to highlight mechanical heterogeneities. This methodology, based on continuum mechanics, was validated in silico with finite-element model strain fields and ultrasound simulations, and in vitro with polyvinyl alcohol cryogel phantoms based on magnetic resonance imaging geometries of carotid plaques. In silico, our results show that the NiV-iMod method: 1) successfully detected and quantified necrotic core inclusions with high positive predictive value (PPV) and sensitivity value (SV) of 81±10% and 91±6%; 2) quantified Young's moduli of necrotic cores, fibrous tissues, and calcium inclusions with mean values of 32±23, 515±30, and 3160±218 kPa (ground true values are 10, 600, and 5000 kPa); and 3) overestimated the cap thickness by . In vitro, the PPV and SV for detecting soft inclusions were 60±21% and 88±9%, and Young's modulus mean values of mimicking lipid, fibrosis, and calcium were 34±19, 193±14, and 649±118 kPa (ground true values are 25±3, 182±21, and 757±87 kPa).
Collapse
|
26
|
Malone A, Browne J, Fagan A. Development of polyvinyl alcohol cyrogel based anatomically realistic vessels for use in Doppler ultrasound flow phantoms. Phys Med 2017. [DOI: 10.1016/j.ejmp.2017.05.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
27
|
He Q, Li GY, Lee FF, Zhang Q, Cao Y, Luo J. Novel Method for Vessel Cross-Sectional Shear Wave Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:1520-1532. [PMID: 28408062 DOI: 10.1016/j.ultrasmedbio.2017.03.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 02/22/2017] [Accepted: 03/06/2017] [Indexed: 06/07/2023]
Abstract
Many studies have investigated the applications of shear wave imaging (SWI) to vascular elastography, mainly on the longitudinal section of vessels. It is important to investigate SWI in the arterial cross section when evaluating anisotropy of the vessel wall or complete plaque composition. Here, we proposed a novel method based on the coordinate transformation and directional filter in the polar coordinate system to achieve vessel cross-sectional shear wave imaging. In particular, ultrasound radiofrequency data were transformed from the Cartesian to the polar coordinate system; the radial displacements were then estimated directly. Directional filtering was performed along the circumferential direction to filter out the reflected waves. The feasibility of the proposed vessel cross-sectional shear wave imaging method was investigated through phantom experiments and ex vivo and in vivo studies. Our results indicated that the dispersion relation of the shear wave (i.e., the guided circumferential wave) within the vessel can be measured via the present method, and the elastic modulus of the vessel can be determined.
Collapse
Affiliation(s)
- Qiong He
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China; Center for Biomedical Imaging Research, Tsinghua University, Beijing, China
| | - Guo-Yang Li
- Institute of Biomechanics and Medical Engineering, AML, Department of Engineering Mechanics, Tsinghua University, Beijing, China
| | - Fu-Feng Lee
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China; Center for Biomedical Imaging Research, Tsinghua University, Beijing, China
| | - Qihao Zhang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Yanping Cao
- Institute of Biomechanics and Medical Engineering, AML, Department of Engineering Mechanics, Tsinghua University, Beijing, China
| | - Jianwen Luo
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China; Center for Biomedical Imaging Research, Tsinghua University, Beijing, China.
| |
Collapse
|
28
|
Lou Z, Yang J, Tang L, Jin Y, Zhang J, Liu C, Li Q. Shear Wave Elastography Imaging for the Features of Symptomatic Carotid Plaques: A Feasibility Study. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2017; 36:1213-1223. [PMID: 28218798 DOI: 10.7863/ultra.16.04073] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Accepted: 08/10/2016] [Indexed: 06/06/2023]
Abstract
OBJECTIVES Shear wave elastography (SWE) was performed to evaluate the Young's modulus of carotid plaques in patients presenting with cerebrovascular incidents, to estimate the clinical value and feasibility of this approach. METHODS Sixty-one patients (mean age, 65 years; 45 men) underwent common duplex ultrasonic examination and SWE evaluation. The patients were divided into the symptomatic and asymptomatic groups based on the presence of unilateral focal neurological symptoms. Elasticity and echogenicity of the carotid plaque was assessed by Young's modulus and Gray-Weale classification, respectively. RESULTS A total of 271 carotid plaques were assessed through duplex ultrasonic examination and SWE imaging. The Bland-Altman test revealed a perfect reproducibility of Young's modulus measurement using SWE. The interframe coefficient of variation was 16% within the 271 plaques. In the 61 representative plaques, significant correlations were found between Gray-Weale classification and mean Young's modulus (r = 0.728, P < .01) when the confounding factors were controlled. The mean Young's modulus of representative plaques in symptomatic group was lower than those in asymptomatic groups (mean Young's modulus: 81 kPa versus 115 kPa; P < .01). Logistic regression combined with receiver operating characteristic analysis suggested increased sensitivity and specificity for the identification of symptomatic carotid plaques when the mean Young's modulus was combined with stenosis rate. CONCLUSIONS Shear wave elastography can evaluate the Young's modulus of carotid plaque stably, and could serve as an additional method for the detection of symptomatic carotid plaques, which, in combination with common ultrasound, can promote the efficiency of differentiating symptomatic carotid plaques.
Collapse
Affiliation(s)
- Zhe Lou
- Department of Cardiovascular Ultrasound, the First Affiliated Hospital of China Medical University, Shenyang, China
| | - Jun Yang
- Department of Cardiovascular Ultrasound, the First Affiliated Hospital of China Medical University, Shenyang, China
| | - Li Tang
- Department of Cardiovascular Ultrasound, the First Affiliated Hospital of China Medical University, Shenyang, China
| | - Youhe Jin
- Department of Cardiovascular Ultrasound, the First Affiliated Hospital of China Medical University, Shenyang, China
| | - Jinsong Zhang
- Department of Cardiovascular Ultrasound, the First Affiliated Hospital of China Medical University, Shenyang, China
| | - Chao Liu
- Department of Cardiovascular Ultrasound, the First Affiliated Hospital of China Medical University, Shenyang, China
| | - Qiaobei Li
- Department of Abdominal Ultrasonic Diagnosis, the First Affiliated Hospital of China Medical University, Shenyang, China
| |
Collapse
|
29
|
Huang C, He Q, Huang M, Huang L, Zhao X, Yuan C, Luo J. Non-Invasive Identification of Vulnerable Atherosclerotic Plaques Using Texture Analysis in Ultrasound Carotid Elastography: An In Vivo Feasibility Study Validated by Magnetic Resonance Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:817-830. [PMID: 28153351 DOI: 10.1016/j.ultrasmedbio.2016.12.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Revised: 11/04/2016] [Accepted: 12/08/2016] [Indexed: 06/06/2023]
Abstract
The aims of this study were to quantify the textural information of strain rate images in ultrasound carotid elastography and evaluate the feasibility of using the textural features in discriminating stable and vulnerable plaques with magnetic resonance imaging as an in vivo reference. Ultrasound radiofrequency data were acquired in 80 carotid plaques from 52 patients, mainly in the longitudinal imaging view, and axial strain rate images were estimated with an ultrasound carotid elastography technique based on an optical flow algorithm. Four textural features of strain rate images-contrast, homogeneity, correlation and angular second moment-were derived based on the gray-level co-occurrence matrix in plaque regions to quantify the deformation distribution pattern. Conventional elastographic indices based on the magnitude of the absolute strain rate, such as the maximum, mean, median, standard deviation and 99th percentile of the axial strain rate, were also obtained for comparison. Composition measurement with magnetic resonance imaging identified 30 plaques as vulnerable and the other 50 as stable. The four textural features, as well as the magnitude of strain rate images, significantly differed between the two groups of plaques. The best performing features for plaque classification were found to be the contrast and 99th percentile of the absolute strain rate, with a comparative area under the receiver operating characteristic curve of 0.81; a slightly higher maximum accuracy of plaque classification can be achieved by the textural feature of contrast (83.8% vs. 81.3%). The results indicate that the use of texture analysis in plaque classification is feasible and that larger local deformations and higher level of complexity in deformation patterns (associated with the elastic or stiffness heterogeneity of plaque tissues) are more likely to occur in vulnerable plaques.
Collapse
Affiliation(s)
- Chengwu Huang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China; Center for Biomedical Imaging Research, Tsinghua University, Beijing, China
| | - Qiong He
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China; Center for Biomedical Imaging Research, Tsinghua University, Beijing, China
| | - Manwei Huang
- Department of Sonography, China Meitan General Hospital, Beijing, China
| | - Lingyun Huang
- Clinical Sites Research Program, Philips Research China, Shanghai, China
| | - Xihai Zhao
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China; Center for Biomedical Imaging Research, Tsinghua University, Beijing, China
| | - Chun Yuan
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China; Center for Biomedical Imaging Research, Tsinghua University, Beijing, China; Department of Radiology, University of Washington, Seattle, Washington, USA
| | - Jianwen Luo
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China; Center for Biomedical Imaging Research, Tsinghua University, Beijing, China.
| |
Collapse
|
30
|
Mulabecirovic A, Vesterhus M, Gilja OH, Havre RF. In Vitro Comparison of Five Different Elastography Systems for Clinical Applications, Using Strain and Shear Wave Technology. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:2572-2588. [PMID: 27570209 DOI: 10.1016/j.ultrasmedbio.2016.07.002] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2016] [Revised: 06/30/2016] [Accepted: 07/02/2016] [Indexed: 06/06/2023]
Abstract
Several different platforms providing ultrasound elastography have emerged in recent years. In this in vitro study on a single tissue-mimicking phantom (CIRS Model 49), we aimed to compare the performance of quantitative elastography measurements from platforms running strain elastography and others running shear wave elastography. We evaluated five different elastography platforms using both linear and curvilinear probes. All measurements were performed in parallel by two independent investigators who recorded the elasticity quantitatively. We investigated intra- and inter-observer agreement by intra-class correlation analysis and coefficient of variation, by correlation and limits of agreement. The reproducibility of elasticity measurements was good to excellent for shear wave and strain elastography. All five elastography platforms had high intra-observer (intra-class correlation coefficient: 0.932-1.0) and inter-observer correlation (intra-class correlation coefficient: 0.845-0.996). All inclusions could be differentiated by quantitative elastography by all systems (p < 0.001). The use of a linear probe yielded more reproducible measurements compared with use of a convex probe in 3/4 platforms.
Collapse
Affiliation(s)
- Anesa Mulabecirovic
- National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, N-5021 Bergen, Norway; Institute of Clinical Medicine, University of Bergen, N-5020, Bergen, Norway
| | - Mette Vesterhus
- National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, N-5021 Bergen, Norway; Norwegian PSC Research Center, Department of Transplantation Medicine, Division of Cancer Medicine, Surgery and Transplantation, Oslo University Hospital Rikshospitalet, Oslo, Norway
| | - Odd Helge Gilja
- National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, N-5021 Bergen, Norway; Institute of Clinical Medicine, University of Bergen, N-5020, Bergen, Norway
| | - Roald Flesland Havre
- National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, N-5021 Bergen, Norway.
| |
Collapse
|
31
|
Mahmood B, Ewertsen C, Carlsen J, Nielsen MB. Ultrasound Vascular Elastography as a Tool for Assessing Atherosclerotic Plaques - A Systematic Literature Review. Ultrasound Int Open 2016; 2:E106-E112. [PMID: 27896334 DOI: 10.1055/s-0042-115564] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2016] [Accepted: 08/05/2016] [Indexed: 02/02/2023] Open
Abstract
Atherosclerosis is a widespread disease that accounts for nearly 3-quarters of deaths due to cardiovascular disease. Ultrasound elastography might be able to reliably identify characteristics associated with vulnerable plaques. There is a need for the evaluation of elastography and its ability to distinguish between vulnerable and stable plaques. The aim of this paper is to provide an overview of the literature on vascular elastography. A systematic search of the available literature for studies using elastography for assessing atherosclerotic plaques was conducted using the MEDLINE, Embase, Cochrane Library and Web of Science databases. A standardized template was used to extract relevant data following the PRISMA 2009 checklist. 20 articles were included in this paper. The studies were heterogeneous. All studies reported that elastography was a feasible technique and provided additional information compared to B-mode ultrasound alone. Most studies reported higher strain values for vulnerable plaques. Ultrasound elastography has potential as a clinical tool in the assessment of atherosclerotic plaques. Elastography is able to distinguish between different plaque types, but there is considerable methodological variation between studies. There is a need for larger studies in a clinical setting to determine the full potential of elastography.
Collapse
Affiliation(s)
- B Mahmood
- Department of Radiology, University Hospital of Copenhagen, Rigshospitalet, Denmark
| | - C Ewertsen
- Department of Radiology, University Hospital of Copenhagen, Rigshospitalet, Denmark
| | - J Carlsen
- Department of Radiology, University Hospital of Copenhagen, Rigshospitalet, Denmark
| | - M B Nielsen
- Department of Radiology, University Hospital of Copenhagen, Rigshospitalet, Denmark
| |
Collapse
|
32
|
de Korte CL, Fekkes S, Nederveen AJ, Manniesing R, Hansen HRHG. Review: Mechanical Characterization of Carotid Arteries and Atherosclerotic Plaques. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1613-1623. [PMID: 27249826 DOI: 10.1109/tuffc.2016.2572260] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Cardiovascular disease (CVD) is a leading cause of death and is in the majority of cases due to the formation of atherosclerotic plaques in arteries. Initially, thickening of the inner layer of the arterial wall occurs. Continuation of this process leads to plaque formation. The risk of a plaque to rupture and thus to induce an ischemic event is directly related to its composition. Consequently, characterization of the plaque composition and its proneness to rupture are of crucial importance for risk assessment and treatment strategies. The carotid is an excellent artery to be imaged with ultrasound because of its superficial position. In this review, ultrasound-based methods for characterizing the mechanical properties of the carotid wall and atherosclerotic plaque are discussed. Using conventional echography, the intima media thickness (IMT) can be quantified. There is a wealth of studies describing the relation between IMT and the risk for myocardial infarction and stroke. Also the carotid distensibility can be quantified with ultrasound, providing a surrogate marker for the cross-sectional mechanical properties. Although all these parameters are associated with CVD, they do not easily translate to individual patient risk. Another technique is pulse wave velocity (PWV) assessment, which measures the propagation of the pressure pulse over the arterial bed. PWV has proven to be a marker for global arterial stiffness. Recently, an ultrasound-based method to estimate the local PWV has been introduced, but the clinical effectiveness still needs to be established. Other techniques focus on characterization of plaques. With ultrasound elastography, the strain in the plaque due to the pulsatile pressure can be quantified. This technique was initially developed using intravascular catheters to image coronaries, but recently noninvasive methods were successfully developed. A high correlation between the measured strain and the risk for rupture was established. Acoustic radiation force impulse (ARFI) imaging also provides characterization of local plaque components based on mechanical properties. However, both elastography and ARFI provide an indirect measure of the elastic modulus of tissue. With shear wave imaging, the elastic modulus can be quantified, although the carotid artery is one of the most challenging tissues for this technique due to its size and geometry. Prospective studies still have to establish the predictive value of these techniques for the individual patient. Validation of ultrasound-based mechanical characterization of arteries and plaques remains challenging. Magnetic resonance imaging is often used as the "gold" standard for plaque characterization, but its limited resolution renders only global characterization of the plaque. CT provides information on the vascular tree, the degree of stenosis, and the presence of calcified plaque, while soft plaque characterization remains limited. Histology still is the gold standard, but is available only if tissue is excised. In conclusion, elastographic ultrasound techniques are well suited to characterize the different stages of vascular disease.
Collapse
|
33
|
Widman E, Maksuti E, Amador C, Urban MW, Caidahl K, Larsson M. Shear Wave Elastography Quantifies Stiffness in Ex Vivo Porcine Artery with Stiffened Arterial Region. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:2423-2435. [PMID: 27425151 DOI: 10.1016/j.ultrasmedbio.2016.05.021] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Revised: 05/17/2016] [Accepted: 05/31/2016] [Indexed: 06/06/2023]
Abstract
Five small porcine aortas were used as a human carotid artery model, and their stiffness was estimated using shear wave elastography (SWE) in the arterial wall and a stiffened artery region mimicking a stiff plaque. To optimize the SWE settings, shear wave bandwidth was measured with respect to acoustic radiation force push length and number of compounded angles used for motion detection with plane wave imaging. The mean arterial wall and simulated plaque shear moduli varied from 41 ± 5 to 97 ± 10 kPa and from 86 ± 13 to 174 ± 35 kPa, respectively, over the pressure range 20-120 mmHg. The results revealed that a minimum bandwidth of approximately 1500 Hz is necessary for consistent shear modulus estimates, and a high pulse repetition frequency using no image compounding is more important than a lower pulse repetition frequency with better image quality when estimating arterial wall and plaque stiffness using SWE.
Collapse
Affiliation(s)
- Erik Widman
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden; Department of Molecular Medicine and Surgery, Karolinska Institutet, Solna, Sweden.
| | - Elira Maksuti
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden; Department of Molecular Medicine and Surgery, Karolinska Institutet, Solna, Sweden
| | - Carolina Amador
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
| | - Matthew W Urban
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota, USA; Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
| | - Kenneth Caidahl
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Solna, Sweden
| | - Matilda Larsson
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden; Department of Molecular Medicine and Surgery, Karolinska Institutet, Solna, Sweden
| |
Collapse
|
34
|
Maksuti E, Widman E, Larsson D, Urban MW, Larsson M, Bjällmark A. Arterial Stiffness Estimation by Shear Wave Elastography: Validation in Phantoms with Mechanical Testing. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:308-21. [PMID: 26454623 DOI: 10.1016/j.ultrasmedbio.2015.08.012] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2015] [Revised: 07/07/2015] [Accepted: 08/17/2015] [Indexed: 05/26/2023]
Abstract
Arterial stiffness is an independent risk factor found to correlate with a wide range of cardiovascular diseases. It has been suggested that shear wave elastography (SWE) can be used to quantitatively measure local arterial shear modulus, but an accuracy assessment of the technique for arterial applications has not yet been performed. In this study, the influence of confined geometry on shear modulus estimation, by both group and phase velocity analysis, was assessed, and the accuracy of SWE in comparison with mechanical testing was measured in nine pressurized arterial phantoms. The results indicated that group velocity with an infinite medium assumption estimated shear modulus values incorrectly in comparison with mechanical testing in arterial phantoms (6.7 ± 0.0 kPa from group velocity and 30.5 ± 0.4 kPa from mechanical testing). To the contrary, SWE measurements based on phase velocity analysis (30.6 ± 3.2 kPa) were in good agreement with mechanical testing, with a relative error between the two techniques of 8.8 ± 6.0% in the shear modulus range evaluated (40-100 kPa). SWE by phase velocity analysis was validated to accurately measure stiffness in arterial phantoms.
Collapse
Affiliation(s)
- Elira Maksuti
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden; Department of Molecular Medicine and Surgery, Karolinska Institutet, Solna, Sweden.
| | - Erik Widman
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden; Department of Molecular Medicine and Surgery, Karolinska Institutet, Solna, Sweden
| | - David Larsson
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden
| | - Matthew W Urban
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
| | - Matilda Larsson
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden; Department of Molecular Medicine and Surgery, Karolinska Institutet, Solna, Sweden
| | - Anna Bjällmark
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden; Department of Molecular Medicine and Surgery, Karolinska Institutet, Solna, Sweden
| |
Collapse
|
35
|
Richards MS, Perucchio R, Doyley MM. Visualizing the stress distribution within vascular tissues using intravascular ultrasound elastography: a preliminary investigation. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1616-31. [PMID: 25837424 PMCID: PMC4510951 DOI: 10.1016/j.ultrasmedbio.2015.01.022] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2014] [Revised: 01/14/2015] [Accepted: 01/17/2015] [Indexed: 05/11/2023]
Abstract
A methodology for computing the stress distribution of vascular tissue using finite element-based, intravascular ultrasound (IVUS) reconstruction elastography is described. This information could help cardiologists detect life-threatening atherosclerotic plaques and predict their propensity to rupture. The calculation of vessel stresses requires the measurement of strain from the ultrasound images, a calibrating pressure measurement and additional model assumptions. In this work, we conducted simulation studies to investigate the effect of varying the model assumptions, specifically Poisson's ratio and the outer boundary conditions, on the resulting stress fields. In both simulation and phantom studies, we created vessel geometries with two fibrous cap thicknesses to determine if we could detect a difference in peak stress (spatially) between the two. The results revealed that (i) Poisson's ratios had negligible impact on the accuracy of stress elastograms, (ii) the outer boundary condition assumption had the greatest effect on the resulting modulus and stress distributions and (iii) in simulation and in phantom experiments, our stress imaging technique was able to detect an increased peak stress for the vessel geometry with the smaller cap thickness. This work is a first step toward understanding and creating a robust stress measurement technique for evaluating atherosclerotic plaques using IVUS elastography.
Collapse
Affiliation(s)
- Michael S Richards
- Department of Electrical & Computer Engineering, University of Rochester, Rochester, New York, USA
| | - Renato Perucchio
- Department of Mechanical Engineering, University of Rochester, Rochester, New York, USA
| | - Marvin M Doyley
- Department of Electrical & Computer Engineering, University of Rochester, Rochester, New York, USA; Department of Biomedical Engineering, University of Rochester, Rochester, New York, USA.
| |
Collapse
|
36
|
Hoskins PR, Kenwright DA. Recent developments in vascular ultrasound technology. ULTRASOUND : JOURNAL OF THE BRITISH MEDICAL ULTRASOUND SOCIETY 2015; 23:158-65. [PMID: 27433252 DOI: 10.1177/1742271x15578778] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
This article describes four technologies relevant to vascular ultrasound which are available commercially in 2015, and traces their origin back through the research literature. The technologies are 3D ultrasound and its use in plaque volume estimation (first described in 1994), colour vector Doppler for flow visualisation (1994), wall motion for estimation of arterial stiffness (1968), and shear wave elastography imaging of the arterial wall (2010). Overall these technologies have contributed to the understanding of vascular disease but have had little impact on clinical practice. The basic toolkit for vascular ultrasound has for the last 25 years been real-time B-mode, colour flow and spectral Doppler. What has changed over this time is improvement in image quality. Looking ahead it is noted that 2D array transducers and high frame rate imaging continue to spread through the commercial vascular ultrasound sector and both have the potential to impact on clinical practice.
Collapse
Affiliation(s)
- P R Hoskins
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, EH16 4TJ
| | - D A Kenwright
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, EH16 4TJ
| |
Collapse
|
37
|
Widman E, Maksuti E, Larsson D, Urban MW, Bjällmark A, Larsson M. Shear wave elastography plaque characterization with mechanical testing validation: a phantom study. Phys Med Biol 2015; 60:3151-74. [PMID: 25803520 DOI: 10.1088/0031-9155/60/8/3151] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
38
|
Liu F, Yong Q, Zhang Q, Liu P, Yang Y. Real-time tissue elastography for the detection of vulnerable carotid plaques in patients undergoing endarterectomy: a pilot study. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:705-712. [PMID: 25619789 DOI: 10.1016/j.ultrasmedbio.2014.10.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2014] [Revised: 09/19/2014] [Accepted: 10/18/2014] [Indexed: 06/04/2023]
Abstract
We examined the utility of ultrasonic real-time tissue elastography (RTE) and conventional B-mode ultrasound (US) in the detection of vulnerable carotid atherosclerotic plaques. This prospective study comprised 19 patients scheduled for carotid endarterectomy. Results obtained from pre-operative RTE and B-mode US and post-operative pathology were compared. RTE encoded low, average and high deformability as blue, green and red, respectively. Tissue hardness was scored on a 5-point scale, and relative strains were calculated. The relative strain was 1.12 ± 0.14 for fibrous plaques (n = 4), 0.28 ± 0.07 for atherosclerotic plaques (n = 5), 0.47 ± 0.31 for intraplaque hemorrhage/thrombosis (n = 5) and 0.98 ± 1.04 for complex plaques (n = 5). The sensitivity, specificity and accuracy of detection of vulnerable plaques were 25%, 100% and 84.2% for B-mode US, 50%, 100% and 89.4% for RTE and 62.5%, 100% and 94.7% for the combination. Ultrasonic RTE is a potential candidate for a non-invasive and effective approach to identify vulnerable atherosclerotic plaques in the carotid artery.
Collapse
Affiliation(s)
- Fengju Liu
- Department of Ultrasound, Capital Medical University Affiliated Beijing Anzhen Hospital, Beijing Institute of Heart, Lung and Blood Vessel Diseases, Beijing, China
| | - Qiang Yong
- Department of Ultrasound, Capital Medical University Affiliated Beijing Anzhen Hospital, Beijing Institute of Heart, Lung and Blood Vessel Diseases, Beijing, China.
| | - Qinyi Zhang
- Stroke Center, Capital Medical University Affiliated Beijing Anzhen Hospital, Beijing Institute of Heart, Lung and Blood Vessel Diseases, Beijing, China
| | - Peng Liu
- Department of Cardiovascular Surgery, China-Japan Friendship Hospital, Beijing, China
| | - Yuguang Yang
- Department of Cardiovascular Surgery, China-Japan Friendship Hospital, Beijing, China
| |
Collapse
|
39
|
Widman E, Caidahl K, Heyde B, D'hooge J, Larsson M. Ultrasound speckle tracking strain estimation of in vivo carotid artery plaque with in vitro sonomicrometry validation. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:77-88. [PMID: 25308946 DOI: 10.1016/j.ultrasmedbio.2014.06.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2014] [Revised: 06/03/2014] [Accepted: 06/23/2014] [Indexed: 06/04/2023]
Abstract
Our objective was to validate a previously developed speckle tracking (ST) algorithm to assess strain in common carotid artery plaques. Radial and longitudinal strain was measured in common carotid artery gel phantoms with a plaque-mimicking inclusion using an in-house ST algorithm and sonomicrometry. Moreover, plaque strain by ST for seven patients (77 ± 6 y) with carotid atherosclerosis was compared with a quantitative visual assessment by two experienced physicians. In vitro, good correlation existed between ST and sonomicrometry peak strains, both radially (r = 0.96, p < 0.001) and longitudinally (r = 0.75, p < 0.01). In vivo, greater pulse pressure-adjusted radial and longitudinal strains were found in echolucent plaques than in echogenic plaques. This illustrates the feasibility of ultrasound ST strain estimation in plaques and the possibility of characterizing plaques using ST strain in vivo.
Collapse
Affiliation(s)
- Erik Widman
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden.
| | - Kenneth Caidahl
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
| | - Brecht Heyde
- Cardiovascular Imaging & Dynamics, Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| | - Jan D'hooge
- Cardiovascular Imaging & Dynamics, Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| | - Matilda Larsson
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden; Cardiovascular Imaging & Dynamics, Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| |
Collapse
|
40
|
Ramnarine KV, Garrard JW, Kanber B, Nduwayo S, Hartshorne TC, Robinson TG. Shear wave elastography imaging of carotid plaques: feasible, reproducible and of clinical potential. Cardiovasc Ultrasound 2014; 12:49. [PMID: 25487290 PMCID: PMC4293004 DOI: 10.1186/1476-7120-12-49] [Citation(s) in RCA: 75] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2014] [Accepted: 11/26/2014] [Indexed: 12/24/2022] Open
Abstract
Background Shear Wave Elastography (SWE) imaging is a novel ultrasound technique for quantifying tissue elasticity. Studies have demonstrated that SWE is able to differentiate between diseased and normal tissue in a wide range clinical applications. However its applicability to atherosclerotic carotid disease has not been established. The aim of this study was to assess the feasibility and potential clinical benefit of using SWE imaging for the assessment of carotid plaques. Methods Eighty-one patients (mean age 76 years, 51 male) underwent greyscale and SWE imaging. Elasticity was quantified by measuring mean Young’s Modulus (YM) within the plaque and within the vessel wall. Echogenicity was assessed using the Gray-Weale classification scale and the greyscale median (GSM). Results Fifty four plaques with stenosis greater than 30% were assessed. Reproducibility of YM measurements, quantified by the inter-frame coefficient of variation, was 22% within the vessel wall and 19% within the carotid plaque. Correlation with percentage stenosis was significant for plaque YM (p = 0.003), but insignificant for plaque GSM (p = 0.46). Plaques associated with focal neurological symptoms had significantly lower mean YM than plaques in asymptomatic patients (62 kPa vs 88 kPa; p = 0.01). Logistic regression and Receiver Operating Characteristic (ROC) analysis showed improvements in sensitivity and specificity when percentage stenosis was combined with the YM (area under ROC = 0.78). Conclusions Our study showed SWE is able to quantify carotid plaque elasticity and provide additional information that may be of clinical benefit to help identify the unstable carotid plaque. Electronic supplementary material The online version of this article (doi:10.1186/1476-7120-12-49) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Kumar V Ramnarine
- Department of Medical Physics, University Hospitals of Leicester NHS Trust, Sandringham Building, Level 1, Leicester Royal Infirmary, Infirmary Square, Leicester LE1 5WW UK.
| | | | | | | | | | | |
Collapse
|
41
|
Hernandez-Andrade E, Aurioles-Garibay A, Garcia M, Korzeniewski SJ, Schwartz AG, Ahn H, Martinez-Varea A, Yeo L, Chaiworapongsa T, Hassan SS, Romero R. Effect of depth on shear-wave elastography estimated in the internal and external cervical os during pregnancy. J Perinat Med 2014; 42:549-57. [PMID: 25029081 PMCID: PMC4183447 DOI: 10.1515/jpm-2014-0073] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2014] [Accepted: 05/19/2014] [Indexed: 12/22/2022]
Abstract
AIM To investigate the effect of depth on cervical shear-wave elastography. METHODS Shear-wave elastography was applied to estimate the velocity of propagation of the acoustic force impulse (shear wave) in the cervix of 154 pregnant women at 11-36 weeks of gestation. Shear-wave speed (SWS) was evaluated in cross-sectional views of the internal and external cervical os in five regions of interest: anterior, posterior, lateral right, lateral left, and endocervix. Distance from the center of the ultrasound (US) transducer to the center of each region of interest was registered. RESULTS In all regions, SWS decreased significantly with gestational age (P=0.006). In the internal os, SWS was similar among the anterior, posterior, and lateral regions and lower in the endocervix. In the external os, the endocervix and anterior regions showed similar SWS values, lower than those from the posterior and lateral regions. In the endocervix, these differences remained significant after adjustment for depth, gestational age, and cervical length. SWS estimations in all regions of the internal os were higher than those of the external os, suggesting denser tissue. CONCLUSION Depth from the US probe to different regions in the cervix did not significantly affect the SWS estimations.
Collapse
Affiliation(s)
- Edgar Hernandez-Andrade
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, Maryland, and Detroit, MI, USA,Department of Obstetrics/Gynecology, Wayne State University School of Medicine, Detroit, MI
| | - Alma Aurioles-Garibay
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, Maryland, and Detroit, MI, USA,Department of Obstetrics/Gynecology, Wayne State University School of Medicine, Detroit, MI
| | - Maynor Garcia
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, Maryland, and Detroit, MI, USA,Department of Obstetrics/Gynecology, Wayne State University School of Medicine, Detroit, MI
| | - Steven J. Korzeniewski
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, Maryland, and Detroit, MI, USA,Department of Obstetrics/Gynecology, Wayne State University School of Medicine, Detroit, MI
| | - Alyse G. Schwartz
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, Maryland, and Detroit, MI, USA,Department of Obstetrics/Gynecology, Wayne State University School of Medicine, Detroit, MI
| | - Hyunyoung Ahn
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, Maryland, and Detroit, MI, USA,Department of Obstetrics/Gynecology, Wayne State University School of Medicine, Detroit, MI
| | - Alicia Martinez-Varea
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, Maryland, and Detroit, MI, USA
| | - Lami Yeo
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, Maryland, and Detroit, MI, USA,Department of Obstetrics/Gynecology, Wayne State University School of Medicine, Detroit, MI
| | - Tinnakorn Chaiworapongsa
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, Maryland, and Detroit, MI, USA,Department of Obstetrics/Gynecology, Wayne State University School of Medicine, Detroit, MI
| | - Sonia S. Hassan
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, Maryland, and Detroit, MI, USA,Department of Obstetrics/Gynecology, Wayne State University School of Medicine, Detroit, MI
| | - Roberto Romero
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, Maryland, and Detroit, MI, USA,Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, MI,Department of Epidemiology and Biostatistics, Michigan State University, East Lansing, MI, USA
| |
Collapse
|
42
|
Kanber B, Hartshorne TC, Horsfield MA, Naylor AR, Robinson TG, Ramnarine KV. Wall motion in the stenotic carotid artery: association with greyscale plaque characteristics, the degree of stenosis and cerebrovascular symptoms. Cardiovasc Ultrasound 2013; 11:37. [PMID: 24139162 PMCID: PMC3818684 DOI: 10.1186/1476-7120-11-37] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2013] [Accepted: 10/04/2013] [Indexed: 11/23/2022] Open
Abstract
Background Systolic dilation of the atherosclerotic carotid artery depends on several factors including arterial compliance and the haemodynamic environment. The purpose of this study was to quantify wall motion in stenotic carotid arteries and investigate any associations with the ultrasound greyscale plaque characteristics, the degree of stenosis, and the presence of cerebrovascular symptoms. Methods Variations in the lumen diameters of 61 stenotic carotid arteries (stenosis range 10%-95%) from 47 patients were measured before the proximal shoulder of the atherosclerotic plaque using ultrasound image sequences over several cardiac cycles. Absolute and percentage diameter changes from diastole to systole were calculated and their relationship to the degree of stenosis, greyscale plaque characteristics, and the presence of ipsilateral hemispheric symptoms were studied. Results The mean absolute diameter change from diastole to systole was 0.45 mm (s.d. 0.17), and the mean percentage diameter change was 6.9% (s.d. 3.1%). Absolute and percentage diameter changes did not have a statistically significant relationship to the degree of stenosis, greyscale plaque characteristics, or the presence of ipsilateral hemispheric symptoms (p > 0.05). Parameters significantly correlated with the presence of symptoms were the degree of stenosis (p = 0.01), plaque greyscale median (p = 0.02) and the plaque surface irregularity index (p = 0.02). Conclusions Our study confirmed the degree of stenosis, plaque greyscale median and our surface irregularity index were significant predictors of symptoms, but found no significant correlation between diameter changes of stenosed carotid arteries and the presence of ipsilateral hemispheric symptoms.
Collapse
Affiliation(s)
| | | | | | | | | | - Kumar V Ramnarine
- Department of Medical Physics, University Hospitals of Leicester NHS Trust, Leicester, LE1 5WW UK.
| |
Collapse
|