Mondou P, Mériaux S, Nageotte F, Vappou J, Novell A, Larrat B. State of the art on microbubble cavitation monitoring and feedback control for blood-brain-barrier opening using focused ultrasound. Phys Med Biol 2023; 68:18TR03. [PMID: 37369229 DOI: 10.1088/1361-6560/ace23e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Accepted: 06/27/2023] [Indexed: 06/29/2023]
Abstract
Focused ultrasound (FUS) is a non-invasive and highly promising method for targeted and reversible blood-brain barrier permeabilization. Numerous preclinical studies aim to optimize the localized delivery of drugs using this method in rodents and non-human primates. Several clinical trials have been initiated to treat various brain diseases in humans using simultaneous BBB permeabilization and drug injection. This review presents the state of the art ofin vitroandin vivocavitation control algorithms for BBB permeabilization using microbubbles (MB) and FUS. Firstly, we describe the different cavitation states, their physical significance in terms of MB behavior and their translation into the spectral composition of the backscattered signal. Next, we report the different indexes calculated and used during the ultrasonic monitoring of cavitation. Finally, the differentin vitroandin vivocavitation control strategies described in the literature are presented and compared.
Collapse
Affiliation(s)
- Paul Mondou
- Université de Strasbourg, CNRS, ICube, UMR7357, Strasbourg, France
- Université Paris-Saclay, CEA, CNRS, BAOBAB, NeuroSpin, 91191, Gif-sur-Yvette, France
| | - Sébastien Mériaux
- Université Paris-Saclay, CEA, CNRS, BAOBAB, NeuroSpin, 91191, Gif-sur-Yvette, France
| | - Florent Nageotte
- Université de Strasbourg, CNRS, ICube, UMR7357, Strasbourg, France
| | - Jonathan Vappou
- Université de Strasbourg, CNRS, ICube, UMR7357, Strasbourg, France
| | - Anthony Novell
- Université Paris-Saclay, CEA, CNRS, BAOBAB, NeuroSpin, 91191, Gif-sur-Yvette, France
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, SHFJ, 91401 , Orsay, France
| | - Benoit Larrat
- Université Paris-Saclay, CEA, CNRS, BAOBAB, NeuroSpin, 91191, Gif-sur-Yvette, France
| |
Collapse
|
2
|
Li Y, Tan C, Yan B, Han T, Yu ACH, Qin P. Evaluation of the properties of daughter bubbles generated by inertial cavitation of preformed microbubbles. ULTRASONICS SONOCHEMISTRY 2021; 72:105400. [PMID: 33341072 PMCID: PMC7803680 DOI: 10.1016/j.ultsonch.2020.105400] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 09/09/2020] [Accepted: 11/07/2020] [Indexed: 05/28/2023]
Abstract
Inertial cavitation (IC) of the preformed microbubbles is being investigated for ultrasound imaging and therapeutic applications. However, microbubbles rupture during IC, creating smaller daughter bubbles (DBs), which may cause undesired bioeffects in the target region. Thus, it is important to determine the properties of DBs to achieve controllable cavitation activity for applications. In this study, we theoretically calculated the dissolution dynamics of sulfur hexafluoride bubbles. Then, we applied a 1-MHz single tone burst with different peak negative pressures (PNPs) and pulse lengths (PLs), and multiple 5-MHz tone bursts with fixed acoustic conditions to elicit IC of the preformed SonoVue microbubbles and scattering of DBs, respectively. After the IC and scattering signals were received by a 7.5-MHz transducer, time- and frequency-domain analysis was performed to obtain the IC dose and scattering intensity curve. The theoretical dissolution curves and measured scattering intensity curves were combined to determine the effect of the incident pulse parameters on the lifetime, mean radius and distribution range of DBs. Increased PNP reduced the lifetime and mean size of the DBs population and narrowed the size distribution. The proportion of small DBs (less than resonance size) increased from 36.83% to 85.98% with an increase in the PNP from 0.6 to 1.6 MPa. Moreover, increased PL caused a shift of the DB population to the smaller bubbles with shorter lifetime and narrower distribution. The proportion of small bubbles increased from 25.74% to 95.08% as the PL was increased from 5 to 100 µs. Finally, increased IC dose caused a smaller mean size, shorter lifetime and narrower distribution in the DB population. These results provide new insight into the relationship between the incident acoustic parameters and the properties of DBs, and a feasible strategy for achieving controllable cavitation activity in applications.
Collapse
Affiliation(s)
- Yanglin Li
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Chunjie Tan
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Bo Yan
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Tao Han
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Alfred C H Yu
- Schlegel Research Institute for Aging, University of Waterloo, Waterloo, ON N2L3G1, Canada
| | - Peng Qin
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
| |
Collapse
|
3
|
Xu T, Cui Z, Li D, Cao F, Xu J, Zong Y, Wang S, Bouakaz A, Wan M, Zhang S. Cavitation characteristics of flowing low and high boiling-point perfluorocarbon phase-shift nanodroplets during focused ultrasound exposures. ULTRASONICS SONOCHEMISTRY 2020; 65:105060. [PMID: 32199255 DOI: 10.1016/j.ultsonch.2020.105060] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 01/15/2020] [Accepted: 03/07/2020] [Indexed: 06/10/2023]
Abstract
This work investigated and compared the dynamic cavitation characteristics between low and high boiling-point phase-shift nanodroplets (NDs) under physiologically relevant flow conditions during focused ultrasound (FUS) exposures at different peak rarefactional pressures. A passive cavitation detection (PCD) system was used to monitor cavitation activity during FUS exposure at various acoustic pressure levels. Root mean square (RMS) amplitudes of broadband noise, spectrograms of the passive cavitation detection signals, and normalized inertial cavitation dose (ICD) values were calculated. Cavitation activity of low-boiling-point perfluoropentane (PFP) NDs and high boiling-point perfluorohexane (PFH) NDs flowing at in vitro mean velocities of 0-15 cm/s were compared in a 4-mm diameter wall-less vessel in a transparent tissue-mimicking phantom. In the static state, both types of phase-shift NDs exhibit a sharp rise in cavitation intensity during initial FUS exposure. Under flow conditions, cavitation activity of the PFH NDs reached the steady state less rapidly compared to PFP NDs under the lower acoustic pressure (1.35 MPa); at the higher acoustic pressure (1.65 MPa), the RMS amplitude increased more sharply during the initial FUS exposure period. In particular, the RMS-time curves of the PFP NDs shifted upward as the mean flow velocity increased from 0 to 15 cm/s; the RMS amplitude of the PFH ND solution increased from 0 to 10 cm/s and decreased at 15 cm/s. Moreover, amplitudes of the echo signal for the low boiling-point PFP NDs were higher compared to the high boiling-point PFH NDs in the lower frequency range, whereas the inverse occurred in the higher frequency range. Both PFP and PFH NDs showed increased cavitation activity in the higher frequency under the flow condition compared to the static state, especially PFH NDs. At 1.65 MPa, normalized ICD values for PFH increased from 0.93 ± 0.03 to 0.96 ± 0.04 and from 0 to 10 cm/s, then decreased to 0.86 ± 0.05 at 15 cm/s. This work contributes to our further understanding of cavitation characteristics of phase-shift NDs under physiologically relevant flow conditions during FUS exposure. In addition, the results provide a reference for selecting suitable phase-shift NDs to enhance the efficiency of cavitation-mediated ultrasonic applications.
Collapse
Affiliation(s)
- Tianqi Xu
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Zhiwei Cui
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Dapeng Li
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Fangyuan Cao
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Jichen Xu
- Institute of Artificial Intelligence and Robotics, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China; National Engineering Laboratory for Visual Information Processing and Applications, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Yujin Zong
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Supin Wang
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | | | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China.
| | - Siyuan Zhang
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China.
| |
Collapse
|
4
|
Zhang S, Xu T, Cui Z, Shi W, Wu S, Zong Y, Niu G, He X, Wan M. Time and Frequency Characteristics of Cavitation Activity Enhanced by Flowing Phase-Shift Nanodroplets and Lipid-Shelled Microbubbles During Focused Ultrasound Exposures. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:2118-2132. [PMID: 31151732 DOI: 10.1016/j.ultrasmedbio.2019.04.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 04/02/2019] [Accepted: 04/25/2019] [Indexed: 06/09/2023]
Abstract
This study investigated and compared the time and frequency characteristics of cavitation activity between phase-shift nanodroplets (NDs) and lipid-shelled microbubbles (MBs) exposed to focused ultrasound (FUS) under physiologically relevant flow conditions. Root-mean-square (RMS) of broadband noise, spectrograms of the passive cavitation detection signals and inertial cavitation doses (ICDs) were calculated during FUS at varying mean flow velocities and two different peak-rarefactional pressures. At a lower pressure of 0.94 MPa, the mean values of the RMS amplitudes versus time for the NDs showed an upward trend but slowed down as the mean flow velocity increased. For flowing NDs, the rate of growth in RMS amplitudes within 2-5 MHz decreased more obviously than those within 5-8 MHz. At a higher pressure of 1.07 MPa, the increase in RMS amplitudes was accelerated as the mean flow velocity increased from 0 to 10 cm/s and slowed down as the mean flow velocity reached 15 cm/s. The general downward trends of RMS amplitudes for the MBs were retarded as the mean flow velocity increased at both acoustic pressures of 0.94 MPa and 1.07 MPa. At 0.94 MPa, the mean ICD value for the NDs decreased from 57 to 36 as the mean flow velocity increased from 0 to 20 cm/s. At 1.07 MPa, the mean ICD value initially increased from 45 to 57 as the mean flow velocity increased from 0 to 10 cm/s and subsequently decreased to 43 as the mean flow velocity reached 20 cm/s. For the MBs, the mean ICD value increased with increasing mean flow velocity at both acoustic pressures. These results could aid in future investigations of cavitation-enhanced FUS with the flowing phase-shift NDs and encapsulated, gas-filled MBs for various applications.
Collapse
Affiliation(s)
- Siyuan Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Tianqi Xu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Zhiwei Cui
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Wen Shi
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Shan Wu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Yujin Zong
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Gang Niu
- Department of Radiology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Xijing He
- Department of Orthopedics, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, People's Republic of China
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China.
| |
Collapse
|
5
|
Chang N, Lu S, Qin D, Xu T, Han M, Wang S, Wan M. Efficient and controllable thermal ablation induced by short-pulsed HIFU sequence assisted with perfluorohexane nanodroplets. ULTRASONICS SONOCHEMISTRY 2018; 45:57-64. [PMID: 29705325 DOI: 10.1016/j.ultsonch.2018.02.033] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2017] [Revised: 02/05/2018] [Accepted: 02/19/2018] [Indexed: 06/08/2023]
Abstract
A HIFU sequence with extremely short pulse duration and high pulse repetition frequency can achieve thermal ablation at a low acoustic power using inertial cavitation. Because of its cavitation-dependent property, the therapeutic outcome is unreliable when the treatment zone lacks cavitation nuclei. To overcome this intrinsic limitation, we introduced perfluorocarbon nanodroplets as extra cavitation nuclei into short-pulsed HIFU-mediated thermal ablation. Two types of nanodroplets were used with perfluorohexane (PFH) as the core material coated with bovine serum albumin (BSA) or an anionic fluorosurfactant (FS) to demonstrate the feasibility of this study. The thermal ablation process was recorded by high-speed photography. The inertial cavitation activity during the ablation was revealed by sonoluminescence (SL). The high-speed photography results show that the thermal ablation volume increased by ∼643% and 596% with BSA-PFH and FS-PFH, respectively, than the short-pulsed HIFU alone at an acoustic power of 19.5 W. Using nanodroplets, much larger ablation volumes were created even at a much lower acoustic power. Meanwhile, the treatment time for ablating a desired volume significantly reduced in the presence of nanodroplets. Moreover, by adjusting the treatment time, lesion migration towards the HIFU transducer could also be avoided. The SL results show that the thermal lesion shape was significantly dependent on the inertial cavitation in this short-pulsed HIFU-mediated thermal ablation. The inertial cavitation activity became more predictable by using nanodroplets. Therefore, the introduction of PFH nanodroplets as extra cavitation nuclei made the short-pulsed HIFU thermal ablation more efficient by increasing the ablation volume and speed, and more controllable by reducing the acoustic power and preventing lesion migration.
Collapse
Affiliation(s)
- Nan Chang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Shukuan Lu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Dui Qin
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Tianqi Xu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Meng Han
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Supin Wang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China.
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China.
| |
Collapse
|
6
|
Zhang S, Shang S, Han Y, Gu C, Wu S, Liu S, Niu G, Bouakaz A, Wan M. Ex Vivo and In Vivo Monitoring and Characterization of Thermal Lesions by High-Intensity Focused Ultrasound and Microwave Ablation Using Ultrasonic Nakagami Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:1701-1710. [PMID: 29969420 DOI: 10.1109/tmi.2018.2829934] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The feasibility of ultrasonic Nakagami imaging to evaluate thermal lesions by high-intensity focused ultrasound and microwave ablation was explored in ex vivo and in vivo liver models. Dynamic changes of the ultrasonic Nakagami parameter in thermal lesions were calculated, and ultrasonic B-mode and Nakagami images were reconstructed simultaneously. The contrast-to-noise ratio (CNR) between thermal lesions and normal tissue was used to estimate the contrast resolution of the monitoring images. After thermal ablation, a bright hyper-echoic region appeared in the ultrasonic B-mode and Nakagami images, identifying the thermal lesion. During thermal ablation, mean values of Nakagami parameter showed an increasing trend from 0.72 to 1.01 for the ex vivo model and 0.54 to 0.72 for the in vivo model. After thermal ablation, mean CNR values of the ultrasonic Nakagami images were 1.29 dB (ex vivo) and 0.80 dB (in vivo), significantly higher ( ) than those for B-mode images. Thermal lesion size, assessed using ultrasonic Nakagami images, shows a good correlation to those obtained from the gross-pathology images (for the ex vivo model: length, = 0.96; width, = 0.90; for the in vivo model: length, = 0.95; width, = 0.85). This preliminary study suggests that ultrasonic Nakagami parameter may have a potential use in evaluating the formation of thermal lesions with better image contrast. Moreover, ultrasonic Nakagami imaging combined with B-mode imaging may be utilized as an alternative modality in developing monitoring systems for image-guided thermal ablation treatments.
Collapse
|
7
|
Zhang S, Xu R, Shang S, Han Y, Liu S, Xu T, Gu C, Zhu X, Niu G, Wan M. In vivo monitoring of microwave ablation in a porcine model using ultrasonic differential attenuation coefficient intercept imaging. Int J Hyperthermia 2018; 34:1157-1170. [DOI: 10.1080/02656736.2018.1437477] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
Affiliation(s)
- Siyuan Zhang
- Department of Biomedical Engineering, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, People’s Republic of China
| | - Ranxiang Xu
- Department of Biomedical Engineering, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, People’s Republic of China
| | - Shaoqiang Shang
- Department of Biomedical Engineering, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, People’s Republic of China
| | - Yuqiang Han
- Department of Biomedical Engineering, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, People’s Republic of China
| | - Sihao Liu
- Department of Biomedical Engineering, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, People’s Republic of China
| | - Tianqi Xu
- Department of Biomedical Engineering, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, People’s Republic of China
| | - Chunming Gu
- Department of Biomedical Engineering, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, People’s Republic of China
| | - Xingguang Zhu
- Department of Biomedical Engineering, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, People’s Republic of China
- Medical Engineering Division, Beijing HuiLongGuan Hospital, Beijing, People's Republic of China
| | - Gang Niu
- Department of Radiology, First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, People’s Republic of China
| | - Mingxi Wan
- Department of Biomedical Engineering, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, People’s Republic of China
| |
Collapse
|
8
|
Guo X, Cai C, Xu G, Yang Y, Tu J, Huang P, Zhang D. Interaction between cavitation microbubble and cell: A simulation of sonoporation using boundary element method (BEM). ULTRASONICS SONOCHEMISTRY 2017; 39:863-871. [PMID: 28733016 DOI: 10.1016/j.ultsonch.2017.06.016] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2017] [Revised: 06/17/2017] [Accepted: 06/18/2017] [Indexed: 05/07/2023]
Abstract
Sonoporation has been widely accepted as a significant tool for gene delivery as well as some bio-effects like hemolysis, bringing in high demands of looking into its underlying mechanism. A two-dimensional (2D) boundary element method (BEM) model was developed to investigate microbubble-cell interaction, especially the morphological and mechanical characteristics around the close-to-bubble point (CP) on cell membrane. Based on time evolution analysis of sonoporation, detailed information was extracted from the model for analysis, including volume expansion ratio of the bubble, areal expansion ratio of the cell, jet velocity and CP displacement. Parametric studies were carried out, revealing the influence of different ultrasound parameters (i.e., driving frequency and acoustic pressure) and geometrical configurations (i.e., bubble-cell distance and initial bubble radius). This model could become a powerful tool not only for understanding bubble-cell interactions, but also for optimizing the strategy of sonoporation, such that it could be safer and of higher efficiency for biological and medical studies especially in clinics.
Collapse
Affiliation(s)
- Xiasheng Guo
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Chenliang Cai
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Guangyao Xu
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Yanye Yang
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Juan Tu
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China.
| | - PinTong Huang
- Department of Ultrasound, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou 310009, China
| | - Dong Zhang
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China; The State Key Laboratory of Acoustics, Chinese Academy of Science, Beijing 10080, China.
| |
Collapse
|
9
|
Zhang S, Han Y, Zhu X, Shang S, Huang G, Zhang L, Niu G, Wang S, He X, Wan M. Feasibility of Using Ultrasonic Nakagami Imaging for Monitoring Microwave-Induced Thermal Lesion in Ex Vivo Porcine Liver. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:482-493. [PMID: 27894833 DOI: 10.1016/j.ultrasmedbio.2016.10.003] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2016] [Revised: 10/05/2016] [Accepted: 10/13/2016] [Indexed: 06/06/2023]
Abstract
The feasibility of using ultrasonic Nakagami imaging to evaluate thermal lesions induced by microwave ablation (MWA) in ex vivo porcine liver was explored. Dynamic changes in echo amplitudes and Nakagami parameters in the region of the MWA-induced thermal lesion, as well as the contrast-to-noise ratio (CNR) between the MWA-induced thermal lesion and the surrounding normal tissue, were calculated simultaneously during the MWA procedure. After MWA exposure, a bright hyper-echoic region appeared in ultrasonic B-mode and Nakagami parameter images as an indicator of the thermal lesion. Mean values of the Nakagami parameter in the thermal lesion region increased to 0.58, 0.71 and 0.91 after 1, 3 and 5 min of MVA. There were no significant differences in envelope amplitudes in the thermal lesion region among ultrasonic B-mode images obtained after different durations of MWA. Unlike ultrasonic B-mode images, Nakagami images were less affected by the shadow effect in monitoring of MWA exposure, and a fairly complete hyper-echoic region was observed in the Nakagami image. The mean value of the Nakagami parameter increased from approximately 0.47 to 0.82 during MWA exposure. At the end of the postablation stage, the mean value of the Nakagami parameter decreased to 0.55 and was higher than that before MWA exposure. CNR values calculated for Nakagami parameter images increased from 0.13 to approximately 0.61 during MWA and then decreased to 0.26 at the end of the post-ablation stage. The corresponding CNR values calculated for ultrasonic B-mode images were 0.24, 0.42 and 0.17. This preliminary study on ex vivo porcine liver suggested that Nakagami imaging have potential use in evaluating the formation of MWA-induced thermal lesions. Further in vivo studies are needed to evaluate the potential application.
Collapse
Affiliation(s)
- Siyuan Zhang
- Key Laboratory of Biomedical Information Engineering, Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China
| | - Yuqiang Han
- Key Laboratory of Biomedical Information Engineering, Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China
| | - Xingguang Zhu
- Key Laboratory of Biomedical Information Engineering, Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China
| | - Shaoqiang Shang
- Key Laboratory of Biomedical Information Engineering, Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China
| | - Guojing Huang
- Key Laboratory of Biomedical Information Engineering, Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China
| | - Lei Zhang
- Key Laboratory of Biomedical Information Engineering, Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China
| | - Gang Niu
- Department of Radiology, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Supin Wang
- Key Laboratory of Biomedical Information Engineering, Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China
| | - Xijing He
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Mingxi Wan
- Key Laboratory of Biomedical Information Engineering, Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China.
| |
Collapse
|