Cheers GM, Weimer LP, Neuerburg C, Arnholdt J, Gilbert F, Thorwächter C, Holzapfel BM, Mayer-Wagner S, Laubach M. Advances in implants and bone graft types for lumbar spinal fusion surgery. Biomater Sci 2024; 12:4875-4902. [PMID: 39190323 DOI: 10.1039/d4bm00848k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/28/2024]
Abstract
The increasing prevalence of spinal disorders worldwide necessitates advanced treatments, particularly interbody fusion for severe cases that are unresponsive to non-surgical interventions. This procedure, especially 360° lumbar interbody fusion, employs an interbody cage, pedicle screw-and-rod instrumentation, and autologous bone graft (ABG) to enhance spinal stability and promote fusion. Despite significant advancements, a persistent 10% incidence of non-union continues to result in compromised patient outcomes and escalated healthcare costs. Innovations in lumbar stabilisation seek to mimic the properties of natural bone, with evolving implant materials like titanium (Ti) and polyetheretherketone (PEEK) and their composites offering new prospects. Additionally, biomimetic cages featuring precisely engineered porosities and interconnectivity have gained traction, as they enhance osteogenic differentiation, support osteogenesis, and alleviate stress-shielding. However, the limitations of ABG, such as harvesting morbidities and limited fusion capacity, have spurred the exploration of sophisticated solutions involving advanced bone graft substitutes. Currently, demineralised bone matrix and ceramics are in clinical use, forming the basis for future investigations into novel bone graft substitutes. Bioglass, a promising newcomer, is under investigation despite its observed rapid absorption and the potential for foreign body reactions in preclinical studies. Its clinical applicability remains under scrutiny, with ongoing research addressing challenges related to burst release and appropriate dosing. Conversely, the well-documented favourable osteogenic potential of growth factors remains encouraging, with current efforts focused on modulating their release dynamics to minimise complications. In this evidence-based narrative review, we provide a comprehensive overview of the evolving landscape of non-degradable spinal implants and bone graft substitutes, emphasising their applications in lumbar spinal fusion surgery. We highlight the necessity for continued research to improve clinical outcomes and enhance patient well-being.
Collapse
Affiliation(s)
- Giles Michael Cheers
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany.
| | - Lucas Philipp Weimer
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany.
| | - Carl Neuerburg
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany.
| | - Jörg Arnholdt
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany.
| | - Fabian Gilbert
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany.
| | - Christoph Thorwächter
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany.
| | - Boris Michael Holzapfel
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany.
| | - Susanne Mayer-Wagner
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany.
| | - Markus Laubach
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany.
- Australian Research Council (ARC) Training Centre for Multiscale 3D Imaging, Modelling and Manufacturing (M3D Innovation), Queensland University of Technology, Brisbane, QLD 4000, Australia
| |
Collapse
|
2
|
Li CC, Yang XL, Wu WW, Zhou R, Jiang YF, Xiao J, Zhang YX, Song L, Dai F. Injectable bone cement cannulated pedicle screw for lumbar degenerative disease in osteoporosis - clinical follow-up of over 5 years. J Orthop Surg Res 2024; 19:440. [PMID: 39068450 PMCID: PMC11282736 DOI: 10.1186/s13018-024-04934-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2024] [Accepted: 07/21/2024] [Indexed: 07/30/2024] Open
Abstract
OBJECTIVE The aim of this study is to evaluate the clinical efficacy of injectable cemented hollow pedicle screw (CICPS) in the treatment of osteoporotic lumbar degenerative diseases through a large sample long-term follow-up study. Additionally, we aim to explore the risk factors affecting interbody fusion. METHODS A total of 98 patients who underwent CICPS for transforaminal lumbar interbody fusion (TLIF) for osteoporotic lumbar degenerative disease from March 2011 to September 2017 were analyzed. X-ray and electronic computed tomography (CT) imaging data were collected during preoperative, postoperative, and follow-up periods. The data included changes in intervertebral space height (ΔH), screw failure, cement leakage (CL), and intervertebral fusion. The patients were divided into two groups based on their fusion status one year after surgery: satisfied group A and dissatisfied group B. Surgical data such as operation time, intraoperative bleeding volume and surgical complications were recorded, and visual analog scale (VAS) and Oswestry disability index (ODI) were used to evaluate the improvement of lumbar and leg pain. RESULTS The mean follow-up time was 101.29 months (ranging from 70 to 128 months). A total of 320 CICPS were used, with 26 screws (8.13%) leaking, 3 screws (0.94%) experiencing cement augmentation failure, and 1 screw (0.31%) becoming loose and breaking. The remaining screws were not loose or pulled out. Female gender, decreased bone density, and CL were identified as risk factors affecting interbody fusion (P < 0.05). Early realization of interbody fusion can effectively prevent the loss of intervertebral space height (P < 0.05) and maintain the surgical treatment effect. Both VAS and ODI scores showed significant improvement during the follow-up period (P < 0.05). Binary logistic regression analysis revealed that decreased bone density and cement leakage were risk factors for prolonged interbody fusion. CONCLUSIONS The results of long-term follow-up indicate that PMMA enhanced CICPS has unique advantages in achieving good clinical efficacy in the treatment of osteoporosis lumbar degenerative diseases. Attention should be paid to identify female gender, severe osteoporosis, and CL as risk factors affecting interbody fusion.
Collapse
Affiliation(s)
- Cong-Can Li
- Department of Orthopaedics, First Affiliated Hospital, Army Medical University, No. 30 Gaotanyanzheng street, Chongqing, 400038, China
| | - Xiu-Lun Yang
- Department of Orthopaedics, First Affiliated Hospital, Army Medical University, No. 30 Gaotanyanzheng street, Chongqing, 400038, China
| | - Wen-Wen Wu
- Chinese People's Liberation Army 132U, Tunchangxian, 571627, China
| | - Rui Zhou
- Department of Orthopaedics, First Affiliated Hospital, Army Medical University, No. 30 Gaotanyanzheng street, Chongqing, 400038, China
| | - Yi-Fan Jiang
- Fourth Department of Convalescence, Sanya Rehabilitation and Convalescent Center, Joint Logistics Support Force, Sanya, 572000, China
| | - Jun Xiao
- Department of Special Service Physiological Training, Guangzhou Special Service Recuperation Center, PLA Rocket Force, Guangzhou, Shantou, 515515, China
| | - Yu-Xuan Zhang
- Department of Special Service Physiological Training, Guangzhou Special Service Recuperation Center, PLA Rocket Force, Guangzhou, Shantou, 515515, China
| | - Lei Song
- Department of Orthopaedics, First Affiliated Hospital, Army Medical University, No. 30 Gaotanyanzheng street, Chongqing, 400038, China.
| | - Fei Dai
- Department of Orthopaedics, First Affiliated Hospital, Army Medical University, No. 30 Gaotanyanzheng street, Chongqing, 400038, China.
| |
Collapse
|
3
|
Jia C, Zhang R, Wang J, Zhang B, Zhang H, Kang L, Zhou L, Shen C. Biomechanical Study of 3 Osteoconductive Materials Applied in Pedicle Augmentation and Revision for Osteoporotic Vertebrae: Allograft Bone Particles, Calcium Phosphate Cement, Demineralized Bone Matrix. Neurospine 2023; 20:1407-1420. [PMID: 38171307 PMCID: PMC10762407 DOI: 10.14245/ns.2346760.380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 09/05/2023] [Accepted: 09/17/2023] [Indexed: 01/05/2024] Open
Abstract
OBJECTIVE This study assessed biomechanical properties of pedicle screws enhanced or revised with 3 materials. We aimed to compare the efficacy of these materials in pedicle augmentation and revision. METHODS One hundred twenty human cadaveric vertebrae were utilized for in vitro testing. Vertebrae bone density was evaluated. Allograft bone particles (ABP), calcium phosphate cement (CPC), and demineralized bone matrix (DBM) were used to augment or revise pedicle screw. Post the implantation of pedicle screws, parameters such as insertional torque, pullout strength, cycles to failure and failure load were measured using specialized instruments. RESULTS ABP, CPC, and DBM significantly enhanced biomechanical properties of the screws. CPC augmentation showed superior properties compared to ABP or DBM. ABP-augmented screws had higher cycles to failure and failure loads than DBM-augmented screws, with no difference in pullout strength. CPC-revised screws exhibited similar strength to the original screws, while ABP-revised screws showed comparable cycles to failure and failure loads but lower pullout strength. DBM-revised screws did not match the original screws' strength. CONCLUSION ABP, CPC, and DBM effectively improve pedicle screw stability for pedicle augmentation. CPC demonstrated the highest efficacy, followed by ABP, while DBM was less effective. For pedicle revision, CPC is recommended as the primary choice, with ABP as an alternative. However, using DBM for pedicle revision is not recommended.
Collapse
Affiliation(s)
- Chongyu Jia
- Department of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China
- Laboratory of Spinal and Spinal Cord Injury Regeneration and Repair, the First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Renjie Zhang
- Department of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China
- Laboratory of Spinal and Spinal Cord Injury Regeneration and Repair, the First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Jiaqi Wang
- Department of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China
- Laboratory of Spinal and Spinal Cord Injury Regeneration and Repair, the First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Bo Zhang
- Department of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China
- Laboratory of Spinal and Spinal Cord Injury Regeneration and Repair, the First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Huaqing Zhang
- Department of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China
- Laboratory of Spinal and Spinal Cord Injury Regeneration and Repair, the First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Liang Kang
- Department of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China
- Laboratory of Spinal and Spinal Cord Injury Regeneration and Repair, the First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Luping Zhou
- Department of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China
- Laboratory of Spinal and Spinal Cord Injury Regeneration and Repair, the First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Cailiang Shen
- Department of Orthopedics and Spine Surgery, the First Affiliated Hospital of Anhui Medical University, Hefei, China
- Laboratory of Spinal and Spinal Cord Injury Regeneration and Repair, the First Affiliated Hospital of Anhui Medical University, Hefei, China
| |
Collapse
|
4
|
A Three-Parameter Weibull Distribution Method to Determine the Fracture Property of PMMA Bone Cement. Polymers (Basel) 2022; 14:polym14173589. [PMID: 36080664 PMCID: PMC9460685 DOI: 10.3390/polym14173589] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Revised: 08/22/2022] [Accepted: 08/24/2022] [Indexed: 11/30/2022] Open
Abstract
Poly (methyl methacrylate) (PMMA) bone cement is an excellent biological material for anchoring joint replacements. Tensile strength ft and fracture toughness KIC have a considerable impact on its application and service life. Considering the variability of PMMA bone cement, a three-parameter Weibull distribution method is suggested in the current study to evaluate its tensile strength and fracture toughness distribution. The coefficients of variation for tensile strength and fracture toughness were the minimum when the characteristic crack of PMMA bone cement was αch∗=8dav. Using the simple equation αch∗=8dav and fictitious crack length Δαfic=1.0dav, the mean value μ (= 43.23 MPa), minimum value ftmin (= 26.29 MPa), standard deviation σ (= 6.42 MPa) of tensile strength, and these values of fracture toughness (μ = 1.77 MPa⋅m1/2, KICmin = 1.02 MPa⋅m1/2, σ = 0.2644 MPa⋅m1/2) were determined simultaneously through experimental data from a wedge splitting test. Based on the statistical analysis, the prediction line between peak load Pmax and equivalent area Ae1Ae2 was obtained with 95% reliability. Nearly all experimental data are located within the scope of a 95% confidence interval. Furthermore, relationships were established between tensile strength, fracture toughness, and peak load Pmax. Consequently, it was revealed that peak load might be used to easily obtain PMMA bone cement fracture characteristics. Finally, the critical geometric dimension value of the PMMA bone cement sample with a linear elastic fracture was estimated.
Collapse
|
5
|
Biomechanical Comparison of Salvage Pedicle Screw Augmentations Using Different Biomaterials. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12157792] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Allograft bone particles, hydroxyapatite/β-hydroxyapatite-tricalcium phosphate (HA/β-TCP), calcium sulfate (CS), and polymethylmethacrylate (PMMA) bone cement are biomaterials clinically used to fill defective pedicles for pedicle screw augmentation. Few studies have systematically investigated the effects of various biomaterials utilized for salvage screw stabilization. The aim of this study was to evaluate the biomechanical properties of screws augmented with these four different materials and the effect of different pilot hole sizes and bone densities on screw fixation strength. Commercially available synthetic bones with three different densities (7.5 pcf, 15pcf, 30 pcf) simulating different degrees of bone density were utilized as substitutes for human bone. Two different pilot hole sizes (3.2 mm and 7.0 mm in diameter) were prepared on test blocks to simulate primary and revision pedicle screw fixation, respectively. Following separate specimen preparation with these four different filling biomaterials, a screw pullout test was conducted using a material test machine, and the average maximal screw pullout strength was compared among groups. The average maximal pullout strength of the materials, presented in descending order, was as follows: bone cement, calcium sulfate, HA/β-TCP, allograft bone chips and the control. In samples in both the 3.2 mm pilot-hole and 7.0 mm pilot-hole groups, the average maximal pullout strength of these four materials increased with increasing bone density. The average maximal pullout strength of the bone cement augmented salvage screw (7.0 mm) was apparently elevated in the 7.5 pcf test block. Salvage pedicle screw augmentation with allograft bone chips, HA/β-TCP, calcium sulfate, and bone cement are all feasible methods and can offer better pullout strength than materials in the non-augmentation group. Bone cement provides the most significantly augmented effect in each pilot hole size and bone density setting and could be considered preferentially to achieve larger initial stability during revision surgery, especially for bones with osteoporotic quality.
Collapse
|
6
|
Wang Y, Liu C, Liu H, Fu H, Li C, Yang L, Sun H. A Novel Calcium Phosphate-Based Nanocomposite for Augmentation of Cortical Bone Trajectory Screw Fixation. Int J Nanomedicine 2022; 17:3059-3071. [PMID: 35844971 PMCID: PMC9278980 DOI: 10.2147/ijn.s365149] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Accepted: 06/26/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose To evaluate the effect of cement augmentation of cortical bone trajectory (CBT) screws using a novel calcium phosphate–based nanocomposite (CPN). Material and Methods CBT screws were placed into cadaveric lumbar vertebrae. Depending on the material used for augmentation, they were divided into the following three groups: CPN, polymethylmethacrylate (PMMA), and control. Radiological imaging was used to evaluate the cement dispersion. Biomechanical tests were conducted to measure the stability of CBT screws. A rat cranial defect model was used to evaluate biodegradation and osseointegration of the CPN. Results After cement augmentation, the CPN tended to disperse into the distal part of the screws, whereas PMMA remained limited to the proximal part of the screws (P < 0.05). As for cement morphology, the CPN tended to form a concentrated mass, whereas PMMA arranged itself as a scattered cement cloud, but the difference was not significant (P > 0.05). The axial pullout test showed that the average maximal pullout force (Fmax) of CPN-augmented CBT screws was similar to that of the PMMA group (CPN, 1639.56 ± 358.21 N vs PMMA, 1778.45 ± 399.83 N; P = 0.745) and was significantly greater than that of the control group (1019.01 ± 371.98 N; P < 0.05). The average torque value in the CPN group was higher than that in the control group (CPN, 1.51 ± 0.78 N∙m vs control, 0.97 ± 0.58 N∙m) and lower than that in the PMMA group (1.93 ± 0.81 N∙m), but there were no statistically significant differences (P > 0.05). The CPN could be biodegraded and gradually replaced by newly formed bone tissue after 12 weeks in a rat cranial defect model. Conclusion The biocompatible CPN could be a valuable augmentation material to enhance CBT screw stability.
Collapse
Affiliation(s)
- Yuetian Wang
- Department of Orthopedics, Peking University First Hospital, Beijing, People's Republic of China
| | - Chun Liu
- Medical Research Centre, Changzhou Second People's Hospital Affiliated to Nanjing Medical University, Jiangsu, People's Republic of China
| | - Huiling Liu
- Institute of Orthopedics, Department of Orthopedics, Soochow University, Suzhou, People's Republic of China
| | - Haoyong Fu
- Department of Orthopedics, Peking University First Hospital, Beijing, People's Republic of China
| | - Chunde Li
- Department of Orthopedics, Peking University First Hospital, Beijing, People's Republic of China
| | - Lei Yang
- Institute of Orthopedics, Department of Orthopedics, Soochow University, Suzhou, People's Republic of China.,Center for Health Sciences and Engineering (CHSE), School of Health Sciences and Biomedical Engineering, Hebei University of Technology, Tianjin, People's Republic of China
| | - Haolin Sun
- Department of Orthopedics, Peking University First Hospital, Beijing, People's Republic of China
| |
Collapse
|
7
|
Prediction of Sacral Screw Loosening after Lumbosacral Surgeries Involving Rigid Fixation of Sacral Bone Using Preoperative Computed Tomography Scans. BIOMED RESEARCH INTERNATIONAL 2022; 2022:7123139. [PMID: 35655477 PMCID: PMC9152424 DOI: 10.1155/2022/7123139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 04/04/2022] [Accepted: 04/30/2022] [Indexed: 11/21/2022]
Abstract
Objective To find a preoperative computed tomography-based method to predict the incidence of sacral screw loosening and assist surgical planning. Methods Surgically treated patients for degenerative lumbosacral disorders with rigid pedicle screw fixation of patients with L5-S1 vertebra in our center from January 2016 to January 2021 were retrospectively included in the current study. CT scan attenuation of the horizontal plane of the sacrum was measured with Hounsfield units (HU). Postoperative X-ray tests were used to diagnose screw loosening. The data was analyzed by independent sample t-tests, X2 analysis, Pearson correlation analysis, and ROC curve analysis. Results A total of 162 (114 male, 48 female, average age 63.7 ± 7.3 years) patients were included in the final analysis. Significant differences were found between the screw loosening group and nonloosening group concerning the HU value of the sacrum at the horizontal plane (P < 0.01). In ROC curve analysis, AUC was 0.674 (95% CI: 0.592-0.756). A cutoff of 200 HU provided 64.8% sensitivity and 62.4% specificity, and a cutoff of 150 HU provided 90.2% sensitivity. Conclusions Analyzing 162 patients with at least 12 months of follow-up, we propose cutoff CT attenuation values of 200 HU and 150 HU to take moderate and radical measures of screw augmentation to prevent screw loosening in the sacral bone.
Collapse
|
8
|
Metallic Implants Used in Lumbar Interbody Fusion. MATERIALS 2022; 15:ma15103650. [PMID: 35629676 PMCID: PMC9146470 DOI: 10.3390/ma15103650] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 05/12/2022] [Accepted: 05/13/2022] [Indexed: 02/07/2023]
Abstract
Over the last decade, pedicle fixation systems have evolved and modifications in spinal fusion techniques have been developed to increase fusion rates and improve clinical outcomes after lumbar interbody fusion (LIF). Regarding materials used for screw and rod manufacturing, metals, especially titanium alloys, are the most popular resources. In the case of pedicle screws, that biomaterial can be also doped with hydroxyapatite, CaP, ECM, or tantalum. Other materials used for rod fabrication include cobalt-chromium alloys and nitinol (nickel-titanium alloy). In terms of mechanical properties, the ideal implant used in LIF should have high tensile and fatigue strength, Young's modulus similar to that of the bone, and should be 100% resistant to corrosion to avoid mechanical failures. On the other hand, a comprehensive understanding of cellular and molecular pathways is essential to identify preferable characteristics of implanted biomaterial to obtain fusion and avoid implant loosening. Implanted material elicits a biological response driven by immune cells at the site of insertion. These reactions are subdivided into innate (primary cellular response with no previous exposure) and adaptive (a specific type of reaction induced after earlier exposure to the antigen) and are responsible for wound healing, fusion, and also adverse reactions, i.e., hypersensitivity. The main purposes of this literature review are to summarize the physical and mechanical properties of metal alloys used for spinal instrumentation in LIF which include fatigue strength, Young's modulus, and corrosion resistance. Moreover, we also focused on describing biological response after their implantation into the human body. Our review paper is mainly focused on titanium, cobalt-chromium, nickel-titanium (nitinol), and stainless steel alloys.
Collapse
|
9
|
Kanno H, Onoda Y, Hashimoto K, Aizawa T, Ozawa H. Innovation of Surgical Techniques for Screw Fixation in Patients with Osteoporotic Spine. J Clin Med 2022; 11:2577. [PMID: 35566703 PMCID: PMC9101243 DOI: 10.3390/jcm11092577] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 04/30/2022] [Accepted: 05/02/2022] [Indexed: 02/04/2023] Open
Abstract
Osteoporosis is a common disease in elderly populations and is a major public health problem worldwide. It is not uncommon for spine surgeons to perform spinal instrumented fusion surgeries for osteoporotic patients. However, in patients with severe osteoporosis, instrumented fusion may result in screw loosening, implant failure or nonunion because of a poor bone quality and decreased pedicle screw stability as well as increased graft subsidence risk. In addition, revision surgeries to correct failed instrumentation are becoming increasingly common in patients with osteoporosis. Therefore, techniques to enhance the fixation of pedicle screws are required in spinal surgeries for osteoporotic patients. To date, various instrumentation methods, such as a supplemental hook, sublaminar taping and sacral alar iliac screws, and modified screwing techniques have been available for reinforcing pedicle screw fixation. In addition, several materials, including polymethylmethacrylate and hydroxyapatite stick/granules, for insertion into prepared screw holes, can be used to enhance screw fixation. Many biomechanical tests support the effectiveness of these augmentation methods. We herein review the current therapeutic strategies for screw fixation and augmentation methods in the surgical treatment of patients with an osteoporotic spine.
Collapse
Affiliation(s)
- Haruo Kanno
- Department of Orthopaedic Surgery, Tohoku Medical and Pharmaceutical University, Sendai 983-8536, Japan;
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, Sendai 980-8574, Japan; (Y.O.); (K.H.); (T.A.)
| | - Yoshito Onoda
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, Sendai 980-8574, Japan; (Y.O.); (K.H.); (T.A.)
| | - Ko Hashimoto
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, Sendai 980-8574, Japan; (Y.O.); (K.H.); (T.A.)
| | - Toshimi Aizawa
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, Sendai 980-8574, Japan; (Y.O.); (K.H.); (T.A.)
| | - Hiroshi Ozawa
- Department of Orthopaedic Surgery, Tohoku Medical and Pharmaceutical University, Sendai 983-8536, Japan;
| |
Collapse
|
10
|
Kanno H, Onoda Y, Hashimoto K, Aizawa T, Ozawa H. Reinforcement of Percutaneous Pedicle Screw Fixation with Hydroxyapatite Granules in Patients with Osteoporotic Spine: Biomechanical Performance and Clinical Outcomes. MEDICINA (KAUNAS, LITHUANIA) 2022; 58:579. [PMID: 35629996 PMCID: PMC9147225 DOI: 10.3390/medicina58050579] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2022] [Revised: 04/01/2022] [Accepted: 04/19/2022] [Indexed: 11/16/2022]
Abstract
In percutaneous pedicle screw (PPS) fixation of the osteoporotic spine, rigid screw fixation obtaining strong stabilization is important for achieving successful treatment outcomes. However, in patients with severe osteoporosis, it is difficult to obtain PPS fixation with sufficient stability. PPS fixation has potential disadvantages with respect to maintaining secure stabilization in comparison to conventional pedicle screw fixation. In PPS fixation, bone grafting to achieve posterior spine fusion is generally not applicable and transverse connectors between the rods cannot be used to reinforce the fixation. Various augmentation methods, including additional hooks, sublaminar bands, and hydroxyapatite (HA) sticks, are available for conventional pedicle screw fixation. On the other hand, there has been no established augmentation method for PPS fixation. Recently, we developed a novel augmentation technique for PPS fixation using HA granules. This technique allows the percutaneous insertion of HA granules into the screw hole along the guidewire prior to insertion of the PPS. We have used this augmentation technique for PPS fixation in various spine surgeries in patients with osteoporosis. In our previous studies, biomechanical analyses demonstrated that PPS fixation was significantly enhanced by augmentation with HA granules in the osteoporotic lumbar spine. Furthermore, augmentation with HA granules was considered to decrease the incidence of screw loosening and implant failure following PPS fixation in patients with osteoporotic spine. In this article, we describe the surgical procedures of the augmentation method using HA granules and summarize our data from the biomechanical analysis of augmentation for PPS fixation. We also review the surgical outcomes of PPS fixation with augmentation using HA granules.
Collapse
Affiliation(s)
- Haruo Kanno
- Department of Orthopaedic Surgery, Tohoku Medical and Pharmaceutical University, Sendai 983-8536, Japan;
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, Sendai 980-8574, Japan; (Y.O.); (K.H.); (T.A.)
| | - Yoshito Onoda
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, Sendai 980-8574, Japan; (Y.O.); (K.H.); (T.A.)
| | - Ko Hashimoto
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, Sendai 980-8574, Japan; (Y.O.); (K.H.); (T.A.)
| | - Toshimi Aizawa
- Department of Orthopaedic Surgery, Tohoku University School of Medicine, Sendai 980-8574, Japan; (Y.O.); (K.H.); (T.A.)
| | - Hiroshi Ozawa
- Department of Orthopaedic Surgery, Tohoku Medical and Pharmaceutical University, Sendai 983-8536, Japan;
| |
Collapse
|
11
|
Hydroxyapatite Use in Spine Surgery—Molecular and Clinical Aspect. MATERIALS 2022; 15:ma15082906. [PMID: 35454598 PMCID: PMC9030649 DOI: 10.3390/ma15082906] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 12/04/2021] [Revised: 04/03/2022] [Accepted: 04/12/2022] [Indexed: 12/12/2022]
Abstract
Hydroxyapatite possesses desirable properties as a scaffold in tissue engineering: it is biocompatible at a site of implantation, and it is degradable to non-toxic products. Moreover, its porosity enables infiltration of cells, nutrients and waste products. The outcome of hydroxyapatite implantation highly depends on the extent of the host immune response. Authors emphasise major roles of the chemical, morphological and physical properties of the surface of biomaterial used. A number of techniques have been applied to transform the theoretical osteoconductive features of HAp into spinal fusion systems—from integration of HAp with autograft to synthetic intervertebral implants. The most popular uses of HAp in spine surgery include implants (ACDF), bone grafts in posterolateral lumbar fusion and transpedicular screws coating. In the past, autologous bone graft has been used as an intervertebral cage in ACDF. Due to the morbidity related to autograft harvesting from the iliac bone, a synthetic cage with osteoconductive material such as hydroxyapatite seems to be a good alternative. Regarding posterolateral lumbar fusion, it requires the graft to induce new bone growth and reinforce fusion between the vertebrae. Hydroxyapatite formulations have shown good results in that field. Moreover, the HAp coating has proven to be an efficient method of increasing screw fixation strength. It can decrease the risk of complications such as screw loosening after pedicle screw fixation in osteoporotic patients. The purpose of this literature review is to describe in vivo reaction to HAp implants and to summarise its current application in spine surgery.
Collapse
|
12
|
Wang Y, Yang L, Li C, Sun H. The Biomechanical Properties of Cement-Augmented Pedicle Screws for Osteoporotic Spines. Global Spine J 2022; 12:323-332. [PMID: 33611971 PMCID: PMC8907649 DOI: 10.1177/2192568220987214] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
STUDY DESIGN This is a broad, narrative review of the literature. OBJECTIVE In this review, we describe recent biomechanics studies on cement-augmented pedicle screws for osteoporotic spines to determine which factors influence the effect of cement augmentation. METHODS A search of Medline was performed, combining the search terms "pedicle screw" and ("augmentation" OR "cement"). Articles published in the past 5 years dealing with biomechanical testing were included. RESULTS Several factors have been identified to impact the effect of cement augmentation in osteoporotic spines. These include the type of augmentation material, the volume of injected cement, the timing of augmentation, the severity of osteoporosis, the design of the pedicle screw, and the specific augmenting technique, among others. CONCLUSIONS This review elaborates the biomechanics of cement-augmented pedicle screws, determines which factors influence the augmentation effect, and identifies the risk factors of cement leakage in osteoporotic bone, which might offer some guidance when using this technique in clinical practice. Further, we provide information about newly designed screws and recently developed augmentation materials that provide higher screw stability as well as fewer cement-related complications.
Collapse
Affiliation(s)
- Yuetian Wang
- Department of Orthopedics, Peking University First
Hospital, Beijing, China
| | - Lei Yang
- Center for Health Science and
Engineering(CHSE), School of Materials Science and Engineering, Hebei University of
Technology, Tianjin, China
| | - Chunde Li
- Department of Orthopedics, Peking University First
Hospital, Beijing, China
| | - Haolin Sun
- Department of Orthopedics, Peking University First
Hospital, Beijing, China,Haolin Sun, Peking University First
Hospital, Beijing 100034, China.
| |
Collapse
|
13
|
Wagner A, Haag E, Joerger AK, Gempt J, Krieg SM, Wostrack M, Meyer B. Cement-Augmented Carbon Fiber-Reinforced Pedicle Screw Instrumentation for Spinal Metastases: Safety and Efficacy. World Neurosurg 2021; 154:e536-e546. [PMID: 34339894 DOI: 10.1016/j.wneu.2021.07.092] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 07/18/2021] [Accepted: 07/19/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To investigate the complication rates and long-term implant failure rates in a monocentric study of a consecutive cohort of patients with thoracolumbar spinal metastases after posterior instrumentation with a fenestrated carbon fiber-reinforced poly-ether-ether-ketone (CFRP) pedicle screw system. METHODS We retrospectively reviewed demographics, Karnofsky Performance Status Scale scores, complications, and implant failure rates. RESULTS Between June 2016 and November 2019, 51 consecutive patients underwent cement-augmented CFRP pedicle screw instrumentation at our institution. Mean age was 68 years (standard deviation 10.5), the median preoperative Karnofsky Performance Status Scale of 80 increased to 90 postoperatively (P = 0.471). Most common primary entities were breast (25.5%), lung (15.7%), and prostate (13.7%) cancers. Of 428 placed screws, 293 (68.5%) were augmented with polymethylmethacrylate, a mean 6 per patient (standard deviation ±2). Screws were inserted via a minimally invasive system technique in 54.9% of cases. In total, 11.8% of patients had immediate postoperative sequelae related to the cement. Pulmonary cement embolisms were noted in 3 patients, 2 had paravertebral extravasation, and 1 had an embolism into a segmental artery. Of these 6, 2 patients with pulmonary embolisms reported related symptoms. Follow-up was available for 80.4%. After a mean 9.8 months, screw loosening was noted in 11.8% of cases on computed tomography, although it was asymptomatic in all but 1 patient. Screw pull-out did not occur. Neither cement-related (P = 0.353) nor general complication rates (P = 0.507) differed significantly between open and minimally invasive system techniques. CONCLUSIONS Percutaneous cement-augmented CFRP pedicle screw instrumentation facilitates artifact-reduced postoperative imaging, while maintaining a risk profile and implant failure rates comparable to conventional metallic instrumentation.
Collapse
Affiliation(s)
- Arthur Wagner
- Department of Neurosurgery, Technical University Munich School of Medicine, Munich, Germany.
| | - Elena Haag
- Department of Neurosurgery, Technical University Munich School of Medicine, Munich, Germany
| | - Ann-Kathrin Joerger
- Department of Neurosurgery, Technical University Munich School of Medicine, Munich, Germany
| | - Jens Gempt
- Department of Neurosurgery, Technical University Munich School of Medicine, Munich, Germany
| | - Sandro M Krieg
- Department of Neurosurgery, Technical University Munich School of Medicine, Munich, Germany
| | - Maria Wostrack
- Department of Neurosurgery, Technical University Munich School of Medicine, Munich, Germany
| | - Bernhard Meyer
- Department of Neurosurgery, Technical University Munich School of Medicine, Munich, Germany
| |
Collapse
|
14
|
Rosinski AA, Mittal A, Odeh K, Ungurean V, Leasure J, Telles C, Kondrashov D. Alternatives to Traditional Pedicle Screws for Posterior Fixation of the Degenerative Lumbar Spine. JBJS Rev 2021; 9:01874474-202107000-00016. [PMID: 34319968 DOI: 10.2106/jbjs.rvw.20.00177] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
BACKGROUND Traditional pedicle screws are currently the gold standard to achieve stable 3-column fixation of the degenerative lumbar spine. However, there are cases in which pedicle screw fixation may not be ideal. Due to their starting point lateral to the pars interarticularis, pedicle screws require a relatively wide dissection along with a medialized trajectory directed toward the centrally located neural elements and prevertebral vasculature. In addition, low bone mineral density remains a major risk factor for pedicle screw loosening, pullout, and pseudarthrosis. The purpose of this article is to review the indications, advantages, disadvantages, and complications associated with posterior fixation techniques of the degenerative lumbar spine beyond the traditional pedicle screws. METHODS Comprehensive literature searches of the PubMed, Scopus, and Web of Science databases were performed for 5 methods of posterior spinal fixation, including (1) cortical bone trajectory (CBT) screws, (2) transfacet screws, (3) translaminar screws, (4) spinous process plates, and (5) fusion mass screws and hooks. Articles that had been published between January 1, 1990, and January 1, 2020, were considered. Non-English-language articles and studies involving fixation of the cervical or thoracic spine were excluded from our review. RESULTS After reviewing over 1,700 articles pertaining to CBT and non-pedicular fixation techniques, a total of 284 articles met our inclusion criteria. CBT and transfacet screws require less-extensive exposure and paraspinal muscle dissection compared with traditional pedicle screws and may therefore reduce blood loss, postoperative pain, and length of hospital stay. In addition, several methods of non-pedicular fixation such as translaminar and fusion mass screws have trajectories that are directed away from or posterior to the spinal canal, potentially decreasing the risk of neurologic injury. CBT, transfacet, and fusion mass screws can also be used as salvage techniques when traditional pedicle screw constructs fail. CONCLUSIONS CBT and non-pedicular fixation may be preferred in certain lumbar degenerative cases, particularly among patients with osteoporosis. Limitations of non-pedicular techniques include their reliance on intact posterior elements and the lack of 3-column fixation of the spine. As a result, transfacet and translaminar screws are infrequently used as the primary method of fixation. CBT, transfacet, and translaminar screws are effective in augmenting interbody fixation and have been shown to significantly improve fusion rates and clinical outcomes compared with stand-alone anterior lumbar interbody fusion. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Alexander A Rosinski
- San Francisco Orthopaedic Residency Program, St. Mary's Medical Center, San Francisco, California
| | - Ashish Mittal
- San Francisco Orthopaedic Residency Program, St. Mary's Medical Center, San Francisco, California
| | - Khalid Odeh
- San Francisco Orthopaedic Residency Program, St. Mary's Medical Center, San Francisco, California
| | | | | | | | - Dimitriy Kondrashov
- San Francisco Orthopaedic Residency Program, St. Mary's Medical Center, San Francisco, California
| |
Collapse
|
15
|
Kumar N, Ramakrishnan SA, Lopez KG, Madhu S, Ramos MRD, Fuh JYH, Hallinan J, Nolan CP, Benneker LM, Vellayappan BA. Can Polyether Ether Ketone Dethrone Titanium as the Choice Implant Material for Metastatic Spine Tumor Surgery? World Neurosurg 2021; 148:94-109. [PMID: 33508491 DOI: 10.1016/j.wneu.2021.01.059] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 01/14/2021] [Accepted: 01/15/2021] [Indexed: 01/08/2023]
Abstract
Instrumentation during metastatic spine tumor surgery (MSTS) provides stability to the spinal column in patients with pathologic fracture or iatrogenic instability produced while undergoing extensive decompression. Titanium is the current implant material of choice in MSTS. However, it hinders radiotherapy planning and generates artifacts, with magnetic resonance imaging and computed tomography scans used for postoperative evaluation of tumor recurrence and/or complications. The high modulus of elasticity of titanium (110 GPa) results in stress shielding, which may lead to construct failure at the bone-implant interface. Polyether ether ketone (PEEK), a thermoplastic polymer, is an emerging alternative to titanium for use in MSTS. The modulus of elasticity of PEEK (3.6 GPa) is close to that of cortical bone (17-21 GPa), resulting in minimal stress shielding. Its radiolucent and nonmetallic properties cause minimal interference with magnetic resonance imaging and computed tomography scans. PEEK also causes low-dose perturbation for radiotherapy planning. However, PEEK has reduced bioactivity with bone and lacks sufficient rigidity to be used as rods in MSTS. The reduced bioactivity of PEEK may be addressed by 1) surface modification (introducing porosity or bioactive coating with hydroxyapatite [HA] or titanium) and 2) forming composites with HA/titanium. The mechanical properties of PEEK may be improved by forming composites with HA or carbon fiber. Despite these modifications, all PEEK and PEEK-based implants are difficult to handle and contour intraoperatively. Our review provides a comprehensive overview of PEEK and modified PEEK implants, with a description of their properties and limitations, potentially serving as a basis for their future development and use in MSTS.
Collapse
Affiliation(s)
- Naresh Kumar
- Department of Orthopaedic Surgery, National University Health System, Singapore.
| | | | - Keith Gerard Lopez
- Department of Orthopaedic Surgery, National University Health System, Singapore
| | - Sirisha Madhu
- Department of Orthopaedic Surgery, National University Health System, Singapore
| | | | - Jerry Ying Hsi Fuh
- Department of Mechanical Engineering, National University of Singapore, Singapore
| | - James Hallinan
- Department of Diagnostic Imaging, National University Hospital, Singapore
| | - Colum P Nolan
- Department of Neurosurgery, National Neuroscience Institute, Singapore
| | - Lorin M Benneker
- Department of Orthopaedics, Spine Surgery, Sonnenhofspital, Bern, Switzerland
| | | |
Collapse
|
16
|
Stramazzo L, Ratano S, Monachino F, Pavan D, Rovere G, Camarda L. Cement augmentation for trochanteric fracture in elderly: A systematic review. J Clin Orthop Trauma 2020; 15:65-70. [PMID: 33717919 PMCID: PMC7920012 DOI: 10.1016/j.jcot.2020.10.034] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 10/06/2020] [Accepted: 10/15/2020] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Cement augmentation of internal fixation of hip fracture has reported to improve fracture stability in osteoporotic hip fractures, reducing the risk of cut-out of the sliding screw through the femoral head. The purpose of present study was to perform a systematic literature review on the effects of augmentation technique in patients with osteoporotic hip fractures. MATERIAL AND METHODS A comprehensive literature search was systematically performed to evaluate all papers published in English language included in the literature between January 2010 and July 2020, according to the PRISMA 2009 guidelines. In vivo and in vitro studies, case reports, review articles, cadaveric studies, biomechanical studies, histological studies, oncological studies, technical notes, studies dealing with radiological classifications and studies on revision surgery were excluded. RESULTS A total of 5 studies involving 301 patients were included. Patients had a mean age of 84.6 years and were followed up for a mean period of 11 months. The proximal femoral fractures were stabilized with implantation of the PFNA or Gamma nail and augmentation was performed with two different cements: polymethylmethacrylate (PMMA) in 4 studies and calcium phosphate (CP) in one study. Overall, 57.5% of patients reached the same or greater preoperative mobility, and postoperative Parker Mobility Score and Harris Hip Score were acceptable. No significantly complications were observed, and no additional surgery related to the implant was required. CONCLUSION The results of this systematic review show that cement augmentation is a safe and effectiveness method of fixation to treat trochanteric fractures.
Collapse
Affiliation(s)
- Leonardo Stramazzo
- Department of Orthopaedic Surgery (DICHIRONS), University of Palermo, Palermo, Italy
| | - Salvatore Ratano
- Department of Orthopaedic Surgery (DICHIRONS), University of Palermo, Palermo, Italy
| | - Francesco Monachino
- Department of Orthopaedic Surgery (DICHIRONS), University of Palermo, Palermo, Italy
| | - Davide Pavan
- Department of Orthopaedic Surgery (DICHIRONS), University of Palermo, Palermo, Italy
| | - Giuseppe Rovere
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli IRCCS - Università Cattolica Del Sacro Cuore, Rome, Italy
| | - Lawrence Camarda
- Department of Orthopaedic Surgery (DICHIRONS), University of Palermo, Palermo, Italy
- Corresponding author. Department of Orthopaedic Surgery (DICHIRONS), University of Palermo, Via del Vespro, 90100, Palermo, Italy.
| |
Collapse
|
17
|
Wekwejt M, Michalska-Sionkowska M, Bartmański M, Nadolska M, Łukowicz K, Pałubicka A, Osyczka AM, Zieliński A. Influence of several biodegradable components added to pure and nanosilver-doped PMMA bone cements on its biological and mechanical properties. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 117:111286. [PMID: 32919647 DOI: 10.1016/j.msec.2020.111286] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Revised: 07/09/2020] [Accepted: 07/21/2020] [Indexed: 01/11/2023]
Abstract
Acrylic bone cements (BC) are wildly used in medicine. Despite favorable mechanical properties, processability and inject capability, BC lack bioactivity. To overcome this, we investigated the effects of selected biodegradable additives to create a partially-degradable BC and also we evaluated its combination with nanosilver (AgNp). We hypothesized that using above strategies it would be possible to obtain bioactive BC. The Cemex was used as the base material, modified at 2.5, 5 or 10 wt% with either cellulose, chitosan, magnesium, polydioxanone or tricalcium-phosphate. The resulted modified BC was examined for surface morphology, wettability, porosity, mechanical and nanomechanical properties and cytocompatibility. The composite BC doped with AgNp was also examined for its release and antibacterial properties. The results showed that it is possible to create modified cement and all studied modifiers increased its porosity. Applying the additives slightly decreased BC wettability and mechanical properties, but the positive effect of the additives was observed in nanomechanical research. The relatively poor cytocompatibility of modified BC was attributed to the unreacted monomer release, except for polydioxanone modification which increased cells viability. Furthermore, all additives facilitated AgNp release and increased BC antibacterial effectiveness. Our present studies suggest the optimal content of biodegradable component for BC is 5 wt%. At this content, an improvement in BC porosity is achieved without significant deterioration of BC physical and mechanical properties. Polydioxanone and cellulose seem to be the most promising additives that improve porosity and antibacterial properties of antibiotic or nanosilver-loaded BC. Partially-degradable BC may be a good strategy to improve their antibacterial effectiveness, but some caution is still required regarding their cytocompatibility. STATEMENT OF SIGNIFICANCE: The lack of bone cement bioactivity is the main limitation of its effectiveness in medicine. To overcome this, we have created composite cements with partially-degradable properties. We also modified these cements with nanosilver to provide antibacterial properties. We examined five various additives at three different contents to modify a selected bone cement. Our results broaden the knowledge about potential modifiers and properties of composite cements. We selected the optimal content and the most promising additives, and showed that the combination of these additives with nanosilver would increase cements` antibacterial effectiveness. Such modified cements may be a new solution for medical applications.
Collapse
Affiliation(s)
- M Wekwejt
- Biomaterials Division, Department of Materials Engineering and Bonding, Gdańsk University of Technology, Gdańsk, Poland.
| | - M Michalska-Sionkowska
- Faculty of Biological and Veterinary Sciences, Department of Environmental Microbiology and Biotechnology, Nicolaus Copernicus University in Toruń, Toruń, Poland
| | - M Bartmański
- Biomaterials Division, Department of Materials Engineering and Bonding, Gdańsk University of Technology, Gdańsk, Poland
| | - M Nadolska
- Faculty of Applied Physics and Mathematics, Gdańsk University of Technology, Gdańsk, Poland
| | - K Łukowicz
- Institute of Zoology and Biomedical Research, Department of Biology and Cell Imaging, Faculty of Biology, Jagiellonian University, Kraków, Poland
| | - A Pałubicka
- Department of Surgical Oncologic, Medical University of Gdańsk, Gdańsk, Poland; Department of Laboratory Diagnostics and Microbiology with Blood Bank, Specialist Hospital in Kościerzyna, Kościerzyna, Poland
| | - A M Osyczka
- Institute of Zoology and Biomedical Research, Department of Biology and Cell Imaging, Faculty of Biology, Jagiellonian University, Kraków, Poland
| | - A Zieliński
- Biomaterials Division, Department of Materials Engineering and Bonding, Gdańsk University of Technology, Gdańsk, Poland
| |
Collapse
|
18
|
Kim JH, Ahn DK, Shin WS, Kim MJ, Lee HY, Go YR. Clinical Effects and Complications of Pedicle Screw Augmentation with Bone Cement: Comparison of Fenestrated Screw Augmentation and Vertebroplasty Augmentation. Clin Orthop Surg 2020; 12:194-199. [PMID: 32489541 PMCID: PMC7237251 DOI: 10.4055/cios19127] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2019] [Accepted: 09/18/2019] [Indexed: 11/25/2022] Open
Abstract
Background Pedicle screw augmentation with bone cement has been experimentally demonstrated to increase the pullout strength. However, the mechanisms of screw loosening are complicated and interacting. Although vertebroplasty augmentation and fenestrated screw augmentation have been compared in many studies, there has been no comparative study on their clinical effects and complications in real clinical settings. We investigated clinical effects of bone cement augmentation of a pedicle screw and differences according to augmentation methods. Methods Of the total 241 patients who had osteoporosis and underwent posterior pedicle screw fixation without anterior bone graft between January 2010 and December 2016, 132 patients with ≥2 years of radiological follow-up were included in this retrospective study. The patients were divided into group I (unaugmented) and group II (bone cement augmented). Group II was subdivided into II-S group (solid screw augmented) and II-F group (fenestrated screw augmented). The incidence of screw loosening was compared between groups I and II. Cement leakage, screw loosening, and screw fractures were investigated in the subgroups. Results In total, 36 of 71 (52%, group I) unaugmented cases and 96 of 170 (56%, group II) augmented cases were followed up for ≥2 years. Of the total 78 solid screw augmented cases, 42 (56%) were in II-S group; 54 of the total 92 (59%) fenestrated screw augmented cases were in II-F group. Groups I and II were homogenous regarding demographic characteristics; II-S and II-F groups were also homogenous. The incidence of screw loosening was 50.0% (18/36) in group I and 7.3% (7/96) in group II (p < 0.001). Cement leakage developed in 2 of 42 (4.8%) cases in II-S group and in 5 of 54 (9.3%) cases in II-F group (p = 0.462). Screw loosening developed in 6 of 42 (14.3%) cases in II-S group and in 1 of 54 cases (1.9%) in II-F group (p = 0.041). Screw fracture developed in none of 42 cases in II-S group and in 3 of 54 cases (5.6%) in II-F group (p = 0.254). Conclusions In osteoporotic patients, bone cement augmentation of a pedicle screw decreased the incidence of screw loosening, and fenestrated screw augmentation was more effective than vertebroplasty augmentation.
Collapse
Affiliation(s)
- Jin Hak Kim
- Department of Orthopedic Surgery, Seoul Sacred Heart General Hospital, Seoul, Korea
| | - Dong Ki Ahn
- Department of Orthopedic Surgery, Seoul Sacred Heart General Hospital, Seoul, Korea
| | - Won Shik Shin
- Department of Orthopedic Surgery, Seoul Sacred Heart General Hospital, Seoul, Korea
| | - Myung Jin Kim
- Department of Orthopedic Surgery, Seoul Sacred Heart General Hospital, Seoul, Korea
| | - Ho Young Lee
- Department of Orthopedic Surgery, Seoul Sacred Heart General Hospital, Seoul, Korea
| | - Young Rok Go
- Department of Orthopedic Surgery, Seoul Sacred Heart General Hospital, Seoul, Korea
| |
Collapse
|
19
|
Criado A, Yokhana S, Rahman T, McCarty S, Andrecovich C, Ren W, Yassir WK. Biomechanical strength comparison of pedicle screw augmentation using poly-dicalcium phosphate dihydrate (P-DCPD) and polymethylmethacrylate (PMMA) cements. Spine Deform 2020; 8:165-170. [PMID: 32030639 DOI: 10.1007/s43390-019-00022-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2019] [Accepted: 08/25/2019] [Indexed: 12/01/2022]
Abstract
STUDY DESIGN A basic science, hypothesis-driven experimental study of the biomechanics of two bone cements in their ability to augment pedicle screws in bone foam. OBJECTIVE The purpose of our study was to compare the pullout and torque resistance of conventional pedicle screws (CPS) augmented with either polymethylmethacrylate (PMMA) or poly-dicalcium phosphate dihydrate (P-DCPD) cement in polyurethane foam blocks mimicking osteoporotic bone. P-DCPD cement has attractive safety characteristics such as non-exothermic curing and drug-eluting capacity. PMMA cement lacks these safety features yet is the current standard in pedicle screw augmentation. METHODS Standardized low-density polyurethane open-cell foam blocks were instrumented with conventional pedicle screws and categorized into three groups of six each. Group 1 was the control group and no cement was used. Groups 2 and 3 were augmented with PMMA and P-DCPD, respectively. An Instron machine applied an axial load to failure at a rate of 2 mm/min for 3 min and a torsional load to failure at a rate of 1°/s. Failure was defined by an evident drop in the load after maximum value. RESULTS Maximal pullout load for PMMA and P-DCPD was significantly greater than control (p < 0.0001). Interestingly, there was no significant difference in the pullout load to failure for the PMMA and P-DCPD groups. Analysis showed significant difference in torsional resistance between PMMA and P-DCPD, with PMMA having greater resistance (p = 0.00436). CONCLUSIONS No difference was observed between PMMA and P-DCPD in pullout load to failure conducted in low-density open-cell, rigid foam blocks. Although a significant difference did exist in our torque analysis, the clinical significance of such a load on a native spine is questionable. Further investigation is warranted for this promising compound that seems to be comparable in pullout resistance to PMMA and offers attractive safety features. LEVEL OF EVIDENCE Basic science, not applicable.
Collapse
Affiliation(s)
- Alberto Criado
- Department of Orthopedic Surgery, Detroit Medical Center, 4201 St Antoine St, Detroit, MI, 48201, USA
| | - Sanar Yokhana
- Department of Orthopedic Surgery, Detroit Medical Center, 4201 St Antoine St, Detroit, MI, 48201, USA
| | - Tahsin Rahman
- Wayne State University School of Medicine, 7733 Woodward Ave, Detroit, MI, 48202, USA.
| | - Scott McCarty
- Department of Orthopedic Surgery, Detroit Medical Center, 4201 St Antoine St, Detroit, MI, 48201, USA
| | - Christopher Andrecovich
- Department of Biomedical Engineering, Wayne State University, 818 W Hancock St, Detroit, MI, 48201, USA
| | - Weiping Ren
- Department of Biomedical Engineering, Wayne State University, 818 W Hancock St, Detroit, MI, 48201, USA
| | - Walid Khaled Yassir
- Department of Orthopedic Surgery, Detroit Medical Center, 4201 St Antoine St, Detroit, MI, 48201, USA
| |
Collapse
|
20
|
Schulze M, Riesenbeck O, Vordemvenne T, Raschke MJ, Evers J, Hartensuer R, Gehweiler D. Complex biomechanical properties of non-augmented and augmented pedicle screws in human vertebrae with reduced bone density. BMC Musculoskelet Disord 2020; 21:151. [PMID: 32143605 PMCID: PMC7060638 DOI: 10.1186/s12891-020-3158-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Accepted: 02/24/2020] [Indexed: 11/26/2022] Open
Abstract
Background In osteoporotic bone, the quality of the bone-to-implant interface is decreased, which may lead to early implant failure. Screw anchorage can be improved by augmentation. This effect is mainly investigated with a pull-out test. To our knowledge, the effect of cement augmentation in an in vivo physiological setup focusing on screw movement has not been investigated to date. The aim of this work was to investigate and compare augmented and native screw behavior in a physiologically related setup. Methods Twelve fresh-frozen human lumbar vertebrae were divided into two groups. Each vertebra was bilaterally instrumented with either non-augmented or augmented pedicle screw systems and loaded in a recently developed test setup that provided cyclic conditions comparable to a physiological gait. The cyclic loading should test the primary implant stability, comparable to the postoperative period of two months in a worst-case scenario in the absence of osseous remodeling. Screws were tracked optically, and screw movement and failure patterns were observed. Results Mutual influence between the left and right sides resulted in a successive, rather than simultaneous, failure. Augmentation of the screws in vertebrae with poor bone quality reduced screw subsidence and thus improved the rigidity of the screw-to-implant interface by up to six-fold. The non-augmented condition was significantly related to early screw failure. Conclusions Pedicle screw system failure involves a complex bilateral-coupled mechanism. The cyclic loading based on physiological conditions during walking has allowed the postoperative conditions and clinical failure mechanisms to be simulated in vitro and clarified. Future implant systems should be investigated with a physiologically related setup.
Collapse
Affiliation(s)
- Martin Schulze
- University Hospital Münster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, 48149, Münster, Germany. .,University Hospital Münster, Department of General Orthopaedics and Tumor Orthopaedics, Albert-Schweitzer-Campus 1, 48149, Münster, Germany.
| | - Oliver Riesenbeck
- University Hospital Münster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, 48149, Münster, Germany
| | - Thomas Vordemvenne
- University Hospital Münster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, 48149, Münster, Germany.,Evangelical Hospital Bethel GmbH, Department of Trauma Surgery and Orthopaedics, Bielefeld, Germany
| | - Michael J Raschke
- University Hospital Münster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, 48149, Münster, Germany
| | - Julia Evers
- University Hospital Münster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, 48149, Münster, Germany
| | - René Hartensuer
- University Hospital Münster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, 48149, Münster, Germany
| | - Dominic Gehweiler
- University Hospital Münster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, 48149, Münster, Germany.,AO Research Institute Davos, Davos, Switzerland
| |
Collapse
|
21
|
Warburton A, Girdler SJ, Mikhail CM, Ahn A, Cho SK. Biomaterials in Spinal Implants: A Review. Neurospine 2019; 17:101-110. [PMID: 31694360 PMCID: PMC7136103 DOI: 10.14245/ns.1938296.148] [Citation(s) in RCA: 61] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Accepted: 09/27/2019] [Indexed: 01/26/2023] Open
Abstract
The aim to find the perfect biomaterial for spinal implant has been the focus of spinal research since the 1800s. Spinal surgery and the devices used therein have undergone a constant evolution in order to meet the needs of surgeons who have continued to further understand the biomechanical principles of spinal stability and have improved as new technologies and materials are available for production use. The perfect biomaterial would be one that is biologically inert/compatible, has a Young’s modulus similar to that of the bone where it is implanted, high tensile strength, stiffness, fatigue strength, and low artifacts on imaging. Today, the materials that have been most commonly used include stainless steel, titanium, cobalt chrome, nitinol (a nickel titanium alloy), tantalum, and polyetheretherketone in rods, screws, cages, and plates. Current advancements such as 3-dimensional printing, the ProDisc-L and ProDisc-C, the ApiFix, and the Mobi-C which all aim to improve range of motion, reduce pain, and improve patient satisfaction. Spine surgeons should remain vigilant regarding the current literature and technological advancements in spinal materials and procedures. The progression of spinal implant materials for cages, rods, screws, and plates with advantages and disadvantages for each material will be discussed.
Collapse
Affiliation(s)
| | | | | | - Amy Ahn
- Mount Sinai Health System, New York, NY, USA
| | | |
Collapse
|
22
|
Kanno H, Aizawa T, Hashimoto K, Itoi E. Enhancing percutaneous pedicle screw fixation with hydroxyapatite granules: A biomechanical study using an osteoporotic bone model. PLoS One 2019; 14:e0223106. [PMID: 31557234 PMCID: PMC6762086 DOI: 10.1371/journal.pone.0223106] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Accepted: 09/13/2019] [Indexed: 11/18/2022] Open
Abstract
Introduction Percutaneous pedicle screw (PPS) can provide internal fixation of the thoracolumbar spine through a minimally invasive surgical procedure. PPS fixation has been widely used to treat various spinal diseases. Rigid fixation of PPS is essential for managing osteoporotic spine in order to prevent the risks of screw loosening and implant failure. We recently developed a novel augmentation method using hydroxyapatite (HA) granules for PPS fixation. The aim of this study was to evaluate the strength and stiffness of PPS fixation augmented with HA granules using an osteoporotic bone model. Methods Screws were inserted into uniform synthetic bone (sawbones) with and without augmentation. The uniaxial pullout strength and insertion torque of the screws were evaluated. In addition, each screw underwent cyclic toggling under incrementally increasing physiological loads until 2 mm of screwhead displacement occurred. The maximal pullout strength (N), maximal insertion torque (N·cm), number of toggle cycles and maximal load (N) required to achieve 2-mm screwhead displacement were compared between the screws with and without augmentation. Results The maximal pullout strength was significantly stronger for screws with augmentation than for those without augmentation (302 ± 19 N vs. 254 ± 17 N, p < 0.05). In addition, the maximal insertion torque was significantly increased in screws with augmentation compared to those without augmentation (48 ± 4 N·cm vs. 26 ± 5 N·cm, p < 0.05). Furthermore, the number of toggle cycles and the maximal load required to reach 2 mm of displacement were significantly greater in screws with augmentation than in those without augmentation (106 ± 9 vs. 52 ± 10 cycles; 152 ± 4 N vs. 124 ± 5 N, p < 0.05). Conclusions Augmentation using HA granules significantly enhanced the rigidity of PPS fixation in the osteoporotic bone model. The present study suggested that novel augmentation with HA granules may be a useful technique for PPS fixation in patients with osteoporotic spine.
Collapse
Affiliation(s)
- Haruo Kanno
- Department of Orthopedic Surgery, Tohoku University School of Medicine, Sendai, Japan
- * E-mail:
| | - Toshimi Aizawa
- Department of Orthopedic Surgery, Tohoku University School of Medicine, Sendai, Japan
| | - Ko Hashimoto
- Department of Orthopedic Surgery, Tohoku University School of Medicine, Sendai, Japan
| | - Eiji Itoi
- Department of Orthopedic Surgery, Tohoku University School of Medicine, Sendai, Japan
| |
Collapse
|
23
|
Principles and current concepts in the surgical treatment of fragility fractures in the elderly. Best Pract Res Clin Rheumatol 2019; 33:264-277. [DOI: 10.1016/j.berh.2019.03.018] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
24
|
Influence of Hydroxyapatite Stick on Pedicle Screw Fixation in Degenerative Lumbar Spine: Biomechanical and Radiologic Study. Clin Spine Surg 2017; 30:E819-E826. [PMID: 27352365 DOI: 10.1097/bsd.0000000000000405] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
STUDY DESIGN A prospective, within-patient, left-right comparative study. OBJECTIVE To evaluate the efficacy of hydroxyapatite (HA) stick augmentation method by comparing the insertional torque of the pedicle screw in osteoporotic and nonosteoporotic patients. SUMMARY OF BACKGROUND DATA Unsatisfactory clinical outcomes after spine surgery in osteoporotic patients are related to pedicle screw loosening or pull-outs. HA, as a bone graft extender, has a possibility to enhance the fixation strength at the bone-screw interface. METHODS From November 2009 to December 2010, among patients who required bilateral pedicle screw fixation for lumbar spine surgery, 22 patients were enrolled, who recieved unilateral HA stick augmentation and completed intraoperative insertional torque measurement of each pedicle screws. On the basis of preoperative evaluation of bone mineral density, patients with osteoporosis had 2 HA sticks inserted unilaterally, and 1 stick for patients without osteoporosis. Pedicle screw loosening and pull-outs were assessed using 12-month postoperative CT scans and follow-up radiographs. Clinical evaluation was done preoperatively and at 1 year postoperatively, based on Visual Analog Scale score, Oswestry Disability Index, and Short Form-36 Health Survey. RESULTS Regardless of bone mineral density, the average torque value of all pedicle screws with HA stick insertion (HA stick inserted group) was significantly higher than that of all pedicle screws without HA insertion (control group) (P<0.0001). Same results were seen in the HA stick inserted subgroups and the control subgroups within both of the osteoporosis group (P=0.009) and the nonosteoporosis group (P=0.0004). There was no statistically significant difference of the rate of pedicle screw loosening in between the HA stick inserted group and the control group. Clinical evaluation also showed no statistically significant difference in between patients with loosening and those without. CONCLUSIONS The enhancement of initial pedicle screw fixation strength in osteoporotic patients can be achieved by HA stick augmentation.
Collapse
|
25
|
Sun H, Liu C, Liu H, Bai Y, Zhang Z, Li X, Li C, Yang H, Yang L. A novel injectable calcium phosphate-based nanocomposite for the augmentation of cannulated pedicle-screw fixation. Int J Nanomedicine 2017; 12:3395-3406. [PMID: 28490878 PMCID: PMC5414751 DOI: 10.2147/ijn.s131962] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Polymethyl methacrylate (PMMA)-augmented cannulated pedicle-screw fixation has been routinely performed for the surgical treatment of lumbar degenerative diseases. Despite its satisfactory clinical outcomes and prevalence, problems and complications associated with high-strength, stiff, and nondegradable PMMA have largely hindered the long-term efficacy and safety of pedicle-screw fixation in osteoporotic patients. To meet the unmet need for better bone cement for cannulated pedicle-screw fixation, a new injectable and biodegradable nanocomposite that was the first of its kind was designed and developed in the present study. The calcium phosphate-based nanocomposite (CPN) exhibited better anti-pullout ability and similar fluidity and dispersing ability compared to clinically used PMMA, and outperformed conventional calcium phosphate cement (CPC) in all types of mechanical properties, injectability, and biodegradability. In term of axial pullout strength, the CPN-augmented cannulated screw reached the highest force of ~120 N, which was higher than that of PMMA (~100 N) and CPC (~95 N). The compressive strength of the CPN (50 MPa) was three times that of CPC, and the injectability of the CPN reached 95%. In vivo tests on rat femur revealed explicit biodegradation of the CPN and subsequent bone ingrowth after 8 weeks. The promising results for the CPN clearly suggest its potential for replacing PMMA in the application of cannulated pedicle-screw fixation and its worth of further study and development for clinical uses.
Collapse
Affiliation(s)
- Haolin Sun
- Department of Orthopedics, Peking University First Hospital, Beijing
| | - Chun Liu
- Department of Orthopedics, Institute of Orthopedics, First Affiliated Hospital
| | - Huiling Liu
- Department of Orthopedics, Institute of Orthopedics, First Affiliated Hospital
| | - Yanjie Bai
- School of Public Health, Medical College
| | - Zheng Zhang
- Department of Orthopedics, Peking University First Hospital, Beijing
| | - Xuwen Li
- Department of Orthopedics, Peking University First Hospital, Beijing
| | - Chunde Li
- Department of Orthopedics, Peking University First Hospital, Beijing
| | - Huilin Yang
- Department of Orthopedics, Institute of Orthopedics, First Affiliated Hospital.,International Research Center for Translational Orthopedics (IRCTO), Soochow University, Suzhou, China
| | - Lei Yang
- Department of Orthopedics, Institute of Orthopedics, First Affiliated Hospital.,International Research Center for Translational Orthopedics (IRCTO), Soochow University, Suzhou, China
| |
Collapse
|
26
|
Cement-augmented screws in a cervical two-level corpectomy with anterior titanium mesh cage reconstruction: a biomechanical study. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2017; 26:1047-1057. [DOI: 10.1007/s00586-017-4951-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2016] [Revised: 11/22/2016] [Accepted: 01/09/2017] [Indexed: 10/20/2022]
|
27
|
Osseodensification for enhancement of spinal surgical hardware fixation. J Mech Behav Biomed Mater 2017; 69:275-281. [PMID: 28113132 DOI: 10.1016/j.jmbbm.2017.01.020] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2016] [Revised: 01/05/2017] [Accepted: 01/12/2017] [Indexed: 01/08/2023]
Abstract
Integration between implant and bone is an essential concept for osseous healing requiring hardware placement. A novel approach to hardware implantation, termed osseodensification, is described here as an effective alternative. 12 sheep averaging 65kg had fixation devices installed in their C2, C3, and C4 vertebral bodies; each device measured 4mm diameter×10mm length. The left-sided vertebral body devices were implanted using regular surgical drilling (R) while the right-sided devices were implanted using osseodensification drilling (OD). The C2 and C4 vertebra provided the t=0 in vivo time point, while the C3 vertebra provided the t=3 and t=6 week time points, in vivo. Structural competence of hardware was measured using biomechanical testing of pullout strength, while the quality and degree of new bone formation and remodeling was assessed via histomorphometry. Pullout strength demonstrated osseodensification drilling to provide superior anchoring when compared to the control group collapsed over time with statistical significance (p<0.01). On Wilcoxon rank signed test, C2 and C4 specimens demonstrated significance when comparing device pullout (p=0.031) for both, and C3 pullout tests at 3 and 6 weeks collapsed over time had significance as well (p=0.027). Percent bone-to-implant contact (%BIC) analysis as a function of drilling technique demonstrated an OD group with significantly higher values relative to the R group (p<0.01). Similarly, percent bone-area-fraction-occupancy (BAFO) analysis presented with significantly higher values for the OD group compared to the R group (p=0.024). As a function of time, between 0 and 3 weeks, a decrease in BAFO was observed, a trend that reversed between 3 and 6 weeks, resulting in a BAFO value roughly equivalent to the t=0 percentage, which was attributed to an initial loss of bone fraction due to remodeling, followed by regaining of bone fraction via production of woven bone. Histomorphological data demonstrated autologous bone chips in the OD group with greater frequency relative to the control, which acted as nucleating surfaces promoting new bone formation around the implants, providing superior stability and greater bone density. This alternative approach to a critical component of hardware implantation encourages assessment of current surgical approaches to hardware implantation.
Collapse
|