1
|
Cheng L, Chen Z, Yang F, Zheng R, He W, Shi F, Liu C, Wang F, Wang L, Xie Y, Lu H. Coronary hemodynamic simulation study. Proc Inst Mech Eng H 2024; 238:444-454. [PMID: 38503717 DOI: 10.1177/09544119241231028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/21/2024]
Abstract
In this paper, a two-way fluid-structure coupling model is developed to simulate and analyze the hemodynamic process based on dynamic coronary angiography, and examine the influence of different hemodynamic parameters on coronary arteries in typical coronary stenosis lesions. Using the measured FFR pressure data of a patient, the pressure-time function curve is fitted to ensure the accuracy of the boundary conditions. The average error of the simulation pressure results compared to the test data is 6.74%. In addition, the results related to blood flow, pressure contour and wall shear stress contour in a typical cardiac cycle are obtained by simulation analysis. These results are found to be in good agreement with the laws of the real cardiac cycle, which verifies the rationality of the simulation. In conclusion, based on the modeling and hemodynamic simulation analysis process of dynamic coronary angiography, this paper proposes a method to assist the analysis and evaluation of coronary hemodynamic and functional parameters, which has certain practical significance.
Collapse
Affiliation(s)
| | | | | | | | - Wenming He
- Department of Cardiology, The Affiliated Hospital of Medical School, Ningbo University, Ningbo, Zhejiang, China
| | - Fan Shi
- Ningbo University, Ningbo, Zhejiang, China
| | - Chang Liu
- Ningbo University, Ningbo, Zhejiang, China
| | | | - Li Wang
- Department of Cardiology, The Affiliated Hospital of Medical School, Ningbo University, Ningbo, Zhejiang, China
| | - Yanqing Xie
- Department of Cardiology, The Affiliated Hospital of Medical School, Ningbo University, Ningbo, Zhejiang, China
| | - Haoxuan Lu
- Department of Cardiology, The Affiliated Hospital of Medical School, Ningbo University, Ningbo, Zhejiang, China
| |
Collapse
|
2
|
Kizhisseri M, Gharaie S, Boopathy SR, Lim RP, Mohammadzadeh M, Schluter J. Differential sensitivities to blood pressure variations in internal carotid and intracranial arteries: a numerical approach to stroke prediction. Sci Rep 2023; 13:22319. [PMID: 38102319 PMCID: PMC10724219 DOI: 10.1038/s41598-023-49591-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Accepted: 12/09/2023] [Indexed: 12/17/2023] Open
Abstract
Stroke remains a global health concern, necessitating early prediction for effective management. Atherosclerosis-induced internal carotid and intra cranial stenosis contributes significantly to stroke risk. This study explores the relationship between blood pressure and stroke prediction, focusing on internal carotid artery (ICA) branches: middle cerebral artery (MCA), anterior cerebral artery (ACA), and their role in hemodynamics. Computational fluid dynamics (CFD) informed by the Windkessel model were employed to simulate patient-specific ICA models with introduced stenosis. Central to our investigation is the impact of stenosis on blood pressure, flow velocity, and flow rate across these branches, incorporating Fractional Flow Reserve (FFR) analysis. Results highlight differential sensitivities to blood pressure variations, with M1 branch showing high sensitivity, ACA moderate, and M2 minimal. Comparing blood pressure fluctuations between ICA and MCA revealed heightened sensitivity to potential reverse flow compared to ICA and ACA comparisons, emphasizing MCA's role. Blood flow adjustments due to stenosis demonstrated intricate compensatory mechanisms. FFR emerged as a robust predictor of stenosis severity, particularly in the M2 branch. In conclusion, this study provides comprehensive insights into hemodynamic complexities within major intracranial arteries, elucidating the significance of blood pressure variations, flow attributes, and FFR in stenosis contexts. Subject-specific data integration enhances model reliability, aiding stroke risk assessment and advancing cerebrovascular disease understanding.
Collapse
Affiliation(s)
- Muhsin Kizhisseri
- School of Engineering, Deakin University, 75 Pigdons Rd, Waurn Ponds, VIC, 3216, Australia
| | - Saleh Gharaie
- School of Engineering, Deakin University, 75 Pigdons Rd, Waurn Ponds, VIC, 3216, Australia.
| | | | | | | | - Jorg Schluter
- School of Engineering, Deakin University, 75 Pigdons Rd, Waurn Ponds, VIC, 3216, Australia
| |
Collapse
|
3
|
Yi H, Yang Z, Johnson M, Bramlage L, Ludwig B. Hemodynamic characteristics in a cerebral aneurysm model using non-Newtonian blood analogues. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2022; 34:103101. [PMID: 36212224 PMCID: PMC9533395 DOI: 10.1063/5.0118097] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Accepted: 09/05/2022] [Indexed: 06/16/2023]
Abstract
This study aims to develop an experimentally validated computational fluid dynamics (CFD) model to estimate hemodynamic characteristics in cerebral aneurysms (CAs) using non-Newtonian blood analogues. Blood viscosities varying with shear rates were measured under four temperatures first, which serves as the reference for the generation of blood analogues. Using the blood analogue, particle image velocimetry (PIV) measurements were conducted to quantify flow characteristics in a CA model. Then, using the identical blood properties in the experiment, CFD simulations were executed to quantify the flow patterns, which were used to compare with the PIV counterpart. Additionally, hemodynamic characteristics in the simplified Newtonian and non-Newtonian models were quantified and compared using the experimentally validated CFD model. Results showed the proposed non-Newtonian viscosity model can predict blood shear-thinning properties accurately under varying temperatures and shear rates. Another developed viscosity model based on the blood analogue can well represent blood rheological properties. The comparisons in flow characteristics show good agreements between PIV and CFD, demonstrating the developed CFD model is qualified to investigate hemodynamic factors within CAs. Furthermore, results show the differences of absolute values were insignificant between Newtonian and non-Newtonian fluids in the distributions of wall shear stress (WSS) and oscillatory shear index (OSI) on arterial walls. However, not only does the simplified Newtonian model underestimate WSS and OSI in most regions of the aneurysmal sac, but it also makes mistakes in identifying the high OSI regions on the sac surface, which may mislead the hemodynamic assessment on the pathophysiology of CAs.
Collapse
Affiliation(s)
- Hang Yi
- Department of Mechanical and Material Engineering, Wright State University, 3640 Colonel Glenn Hwy., Dayton, Ohio 45435, USA
| | - Zifeng Yang
- Department of Mechanical and Material Engineering, Wright State University, 3640 Colonel Glenn Hwy., Dayton, Ohio 45435, USA
| | - Mark Johnson
- Department of Mechanical and Material Engineering, Wright State University, 3640 Colonel Glenn Hwy., Dayton, Ohio 45435, USA
| | - Luke Bramlage
- Boonshoft School of Medicine, Wright State University, Dayton, Ohio 45435, USA
| | | |
Collapse
|
4
|
Peng C, Liu J, He W, Qin W, Yuan T, Kan Y, Wang K, Wang S, Shi Y. Numerical simulation in the abdominal aorta and the visceral arteries with or without stenosis based on 2D PCMRI. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2022; 38:e3569. [PMID: 34967124 DOI: 10.1002/cnm.3569] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 12/10/2021] [Accepted: 12/27/2021] [Indexed: 06/14/2023]
Abstract
It is important to obtain accurate boundary conditions (BCs) in hemodynamic simulations. This article aimed to improve the accuracy of BCs in computational fluid dynamics (CFD) simulation and analyze the differences in hemodynamics between healthy volunteers and patients with visceral arterial stenosis (VAS). The geometric models of seven cases were reconstructed using the magnetic resonance angiogram (MRA) or computed tomography angiogram (CTA) imaging data. The physiological flow waveforms obtained from 2D Phase Contrast Magnetic Resonance Imaging (PCMRI) were imposed on the aortic inlet and the visceral arteries' outlets. The individualized RCR values of the three-element Windkessel model were imposed on the aortic outlet. CFD simulations were run in the open-source software: svSolver. Two specific time points were selected to compare the hemodynamics of healthy volunteers and patients with VAS. The results suggested that blood in the stenotic visceral arteries flowed at high speed throughout the cardiac cycle. The low pressure is distributed at stenotic lesions. The wall shear stress (WSS) reached 4 Pa near stenotic locations. The low time average wall shear stress (TAWSS), high oscillatory shear index (OSI), and high relative residence time (RRT) concentrated in the abdominal aorta. Besides, the ratios of the areas with low TAWSS, high OSI, and high RRT to the computational domain were higher in patients with VAS than which in the healthy volunteers. The individualized BCs were used for hemodynamic simulations and results suggest that patients with stenosis have a higher risk of blood retention and atherosclerosis formation in the abdominal aorta.
Collapse
Affiliation(s)
- Chen Peng
- Department of Aeronautics and Astronautics, Institute of Biomechanics, Fudan University, Shanghai, China
| | - Junzhen Liu
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Wei He
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Wang Qin
- Department of Aeronautics and Astronautics, Institute of Biomechanics, Fudan University, Shanghai, China
| | - Tong Yuan
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Yuanqing Kan
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Keqiang Wang
- Institute of Panvascular Medicine, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Shengzhang Wang
- Department of Aeronautics and Astronautics, Institute of Biomechanics, Fudan University, Shanghai, China
- Institute of Biomedical Engineering Technology, Academy for Engineering and Technology, Fudan University, Shanghai, China
| | - Yun Shi
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| |
Collapse
|
5
|
Yuan J, Li Z, Jiang X, Lai N, Wang X, Zhao X, Wu D, Liu J, Xia D, Huang C, Fang X. Hemodynamic and Morphological Differences Between Unruptured Carotid-Posterior Communicating Artery Bifurcation Aneurysms and Infundibular Dilations of the Posterior Communicating Artery. Front Neurol 2020; 11:741. [PMID: 32793106 PMCID: PMC7393924 DOI: 10.3389/fneur.2020.00741] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Accepted: 06/16/2020] [Indexed: 11/13/2022] Open
Abstract
Objective: Posterior communicating artery bifurcation aneurysms (PcomA-BAs) and infundibular dilations (PcomA-IDs) are found at the junction between the internal carotid artery (ICA) and the posterior communicating artery (PcomA). Several studies found that PcomA-IDs potentially progress to aneurysms and can even rupture. In our clinical practice, digital subtraction angiography (DSA) helps differentiate PcomA-IDs from unruptured PcomA-BAs. However, when PcomA-IDs are >3 mm in diameter or PcomA are absent on DSA, it is challenging to use DSA to differentiate PcomA-IDs from unruptured PcomA-BAs. Hemodynamic and morphological factors are thought to play important roles in the pathogenesis, progression, and rupture of cerebral aneurysms. We compared hemodynamic and morphological differences in unruptured PcomA-BAs and PcomA-IDs to better manage PcomA-IDs. Methods: We included 83 PcomA-IDs and 115 unruptured PcomA-BAs dignosed and measured using DSA from January 2015 to January 2019. Computational fluid dynamics was performed on these patient-specific models reconstructed using axial slices in DICOM format. Clinical, hemodynamic, and morphological factors were compared between the PcomA-IDs and PcomA-BAs. Significant parameters were analyzed using binary logistic regression analysis to identify independent risk factors. Receiver operating characteristic (ROC) analysis was performed on the independent risk factors to acquire cutoff values. Results: One hemodynamic and four morphyological parameters were significantly different between PcomA-IDs and PcomA-BAs: normalized wall shear stress (NWSS), size, the angle between the ophthalmic segment of the ICA and the PcomA (APcomA), the angle between the ophthalmic and the communicating segment of the ICA (AICA) and the diameter of the PcomA (DPcomA). Binary logistic regression analysis showed that small size and DPcomA as well as APcomA were all independent significant factors characterizing the status of PcomA-IDs and the ROC analysis for independent risk factors indicated the cutoff values of size, APcomA, and DPcomA were 3.45 mm, 66.27°, and 1.24 mm, respectively. Conclusions: Size, DpcomA, and ApcomA could independently characterize the status of PcomA-IDs. These might help us better differentiate them from real aneurysms and guide its management.
Collapse
Affiliation(s)
- Jinlong Yuan
- Department of Neurosurgery, The First Affiliated Hospital of Wannan Medical College (Yijishan Hospital), Wuhu, China
| | - Zhenbao Li
- Department of Neurosurgery, The First Affiliated Hospital of Wannan Medical College (Yijishan Hospital), Wuhu, China
| | - Xiaochun Jiang
- Department of Neurosurgery, The First Affiliated Hospital of Wannan Medical College (Yijishan Hospital), Wuhu, China
| | - Niansheng Lai
- Department of Neurosurgery, The First Affiliated Hospital of Wannan Medical College (Yijishan Hospital), Wuhu, China
| | - Xuanzhi Wang
- Department of Neurosurgery, The First Affiliated Hospital of Wannan Medical College (Yijishan Hospital), Wuhu, China
| | - Xintong Zhao
- Department of Neurosurgery, The First Affiliated Hospital of Wannan Medical College (Yijishan Hospital), Wuhu, China
| | - Degang Wu
- Department of Neurosurgery, The First Affiliated Hospital of Wannan Medical College (Yijishan Hospital), Wuhu, China
| | - Jiaqiang Liu
- Department of Neurosurgery, The First Affiliated Hospital of Wannan Medical College (Yijishan Hospital), Wuhu, China
| | - Dayong Xia
- Department of Neurosurgery, The First Affiliated Hospital of Wannan Medical College (Yijishan Hospital), Wuhu, China
| | - Chenlei Huang
- Department of Clinical Laboratory, The First Affiliated Hospital of Wannan Medical College (Yijishan Hospital), Wuhu, China
| | - Xinggen Fang
- Department of Neurosurgery, The First Affiliated Hospital of Wannan Medical College (Yijishan Hospital), Wuhu, China
| |
Collapse
|