1
|
Pradeep K, Pal B, Mukherjee K, Shetty GM. Finite element analysis of implanted lumbar spine: Effects of open laminectomy plus PLF and open laminectomy plus TLIF surgical approaches on L3-L4 FSU. Med Eng Phys 2024; 128:104178. [PMID: 38789215 DOI: 10.1016/j.medengphy.2024.104178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 03/15/2024] [Accepted: 05/06/2024] [Indexed: 05/26/2024]
Abstract
Several finite element (FE) studies reported performances of various lumbar fusion surgical approaches. However, comparative studies on the performance of Open Laminectomy plus Posterolateral Fusion (OL-PLF) and Open Laminectomy plus Transforaminal Interbody Fusion (OL-TLIF) surgical approaches are rare. In the current FE study, the variation in ranges of motions (ROM), stress-strain distributions in an implanted functional spinal unit (FSU) and caudal adjacent soft structures between OL-PLF and OL-TLIF virtual models were investigated. The implanted lumbar spine FE models were developed from subject-specific computed tomography images of an intact spine and solved for physiological loadings such as compression, flexion, extension and lateral bending. Reductions in the ROMs of L1-L5 (49 % to 59 %) and L3-L4 implanted FSUs (91 % to 96 %) were observed for both models. Under all the loading cases, the maximum von Mises strain observed in the implanted segment of both models exceeds the mean compressive yield strain for the vertebra. The maximum von Mises stress and strain observed on the caudal adjacent soft structures of both the implanted models are at least 22 % higher than the natural spine model. The findings indicate the risk of failure in the implanted FSUs and higher chances of adjacent segment degeneration for both models.
Collapse
Affiliation(s)
- Kishore Pradeep
- Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology (IIEST), Shibpur, Howrah 711103, West Bengal, India
| | - Bidyut Pal
- Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology (IIEST), Shibpur, Howrah 711103, West Bengal, India.
| | - Kaushik Mukherjee
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110 016, India
| | - Gautam M Shetty
- QI Spine Clinic, Mumbai, India; Knee & Orthopaedic Clinic, Mumbai, India
| |
Collapse
|
2
|
Li JR, Yan Y, Wu XG, He LM, Feng HY. Biomechanical evaluation of Percutaneous endoscopic posterior lumbar interbody fusion and minimally invasive transforaminal lumbar interbody fusion: a biomechanical analysis. Comput Methods Biomech Biomed Engin 2024; 27:285-295. [PMID: 36847747 DOI: 10.1080/10255842.2023.2183348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 02/12/2023] [Accepted: 02/15/2023] [Indexed: 03/01/2023]
Abstract
In order to analyze and evaluate the stability of lumbar spine and the risk of cage subsidence after different minimally invasive fusion operations, two finite element models Percutaneous endoscopic posterior lumbar interbody fusion (PE-PLIF) and minimally invasive transforaminal lumbar interbody Fusion (MIS-TLIF) were established. The results showed that compared with MIS-TLIF, PE-PLIF had better segmental stability, lower pedicle screw rod system stress, and lower risk of cage subsidence. The results suggest that the cage with appropriate height should be selected to ensure the segmental stability and avoid the risk of the subsidence caused by the cage with large height.
Collapse
Affiliation(s)
- Jia-Rui Li
- Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, China
| | - Yang Yan
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, China
| | - Xiao-Gang Wu
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, China
| | - Li-Ming He
- Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, China
| | - Hao-Yu Feng
- Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, China
| |
Collapse
|
3
|
Zhang Y, Du S, Aiyiti W, Teng Y, Jia R, Jiang H. Customized design and biomechanical property analysis of 3D-printed tantalum intervertebral cages. Biomed Mater Eng 2024; 35:99-124. [PMID: 38217572 DOI: 10.3233/bme-230154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2024]
Abstract
BACKGROUND Intervertebral cages used in clinical applications were often general products with standard specifications, which were challenging to match with the cervical vertebra and prone to cause stress shielding and subsidence. OBJECTIVE To design and fabricate customized tantalum (Ta) intervertebral fusion cages that meets the biomechanical requirements of the cervical segment. METHODS The lattice intervertebral cages were customized designed and fabricated by the selective laser melting. The joint and muscle forces of the cervical segment under different movements were analyzed using reverse dynamics method. The stress characteristics of cage, plate, screws and vertebral endplate were analyzed by finite element analysis. The fluid flow behaviors and permeability of three lattice structures were simulated by computational fluid dynamics. Compression tests were executed to investigate the biomechanical properties of the cages. RESULTS Compared with the solid cages, the lattice-filled structures significantly reduced the stress of cages and anterior fixation system. In comparison to the octahedroid and quaddiametral lattice-filled cages, the bitriangle lattice-filled cage had a lower stress shielding rate, higher permeability, and superior subsidence resistance ability. CONCLUSION The inverse dynamics simulation combined with finite element analysis is an effective method to investigate the biomechanical properties of the cervical vertebra during movements.
Collapse
Affiliation(s)
- Yutao Zhang
- School of Mechanical Engineering, Xinjiang University, Urumqi, China
| | - Shu Du
- School of Mechanical Engineering, Xinjiang University, Urumqi, China
| | - Wurikaixi Aiyiti
- School of Mechanical Engineering, Xinjiang University, Urumqi, China
| | - Yong Teng
- Department of Orthopaedics, Hospital of Xinjiang Military Region PLA, Urumqi, China
| | - Ru Jia
- School of Mechanical Engineering, Xinjiang University, Urumqi, China
| | - Houfeng Jiang
- School of Mechanical Engineering, Xinjiang University, Urumqi, China
| |
Collapse
|
4
|
Pradeep K, Pal B. Effects of open and minimally invasive Transforaminal Lumbar Interbody Fusion (TLIF) surgical techniques on mechanical behaviour of fused L3-L4 FSU: A comparative finite element study. Med Eng Phys 2024; 123:104084. [PMID: 38365336 DOI: 10.1016/j.medengphy.2023.104084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 11/30/2023] [Accepted: 12/10/2023] [Indexed: 02/18/2024]
Abstract
For predicting the biomechanical effects of the fusion procedure, finite element (FE) analysis is widely used as a preclinical tool. Although several FE studies examined the efficacies of various fusion surgical techniques, comparative studies on Open and minimally invasive (MIS) transforaminal lumbar interbody fusion (TLIF) procedures incorporating a follower coordinate system have not been investigated yet. The current FE study evaluates the ranges of motion (ROM) and load distributions of Open-TLIF and MIS-TLIF implanted models, under physiological loading such as compression, flexion, extension and lateral bending. The most noteworthy finding from the investigation is that both the fusion procedures significantly reduced the ROMs of the implanted segment (L3-L4) and full model (L1-L5) by at least 89 % and 44 %, respectively, compared to the intact model. For all loading situations, over 95 % of the implanted models' cancellous bone volume was subjected to von Mises strains ranging from 0.0003 to 0.005. The maximum von Mises strain was observed to be localized on a small amount of cancellous bone volume (<5 %). The likelihood of adjacent segment degeneration is higher in the case of MIS-TLIF due to the higher stress (22-53 MPa) and strain (0.018-0.087) noticed on the upper facet of the L3 vertebra.
Collapse
Affiliation(s)
- Kishore Pradeep
- Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology (IIEST), Shibpur, Howrah 711103, West Bengal, India
| | - Bidyut Pal
- Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology (IIEST), Shibpur, Howrah 711103, West Bengal, India.
| |
Collapse
|
5
|
Zeng Q, Liao Y, Pou K, Chen Q, Li Y, Cai L, Huang Z, Tang S. Does Lumbar Interbody Fusion Modality Affect the Occurrence of Complications in an Osteoporotic Spine Under Whole-Body Vibration? A Finite Element Study. World Neurosurg 2023; 176:e297-e305. [PMID: 37224957 DOI: 10.1016/j.wneu.2023.05.053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Accepted: 05/15/2023] [Indexed: 05/26/2023]
Abstract
OBJECTIVE To evaluate the effects of 3 lumbar interbody fusion techniques on the occurrence of complications in an osteoporotic spine under whole-body vibration. METHODS A previously developed and validated nonlinear finite element model of L1-S1was modified to develop anterior lumbar interbody fusion (ALIF), posterior lumbar interbody fusion (PLIF), and transforaminal lumbar interbody fusion (TLIF) models with osteoporosis. In each model, the lower surface of the sacrum was absolutely fixed, a follower load of 400N was applied through the axis of the lumbar spine, and an axial sinusoidal vertical load of ±40N (5 Hz) was imposed on the superior surface of L1, to perform a transient dynamic analysis. The maximal values of intradiscal pressure, shear stress on annulus substance, disc bulge, facet joint stress, and screw and rod stress, along with their dynamic response curves, were collected. RESULTS Among these 3 models, the TLIF model generated the greatest screw and rod stress, and the PLIF model generated the greatest cage-bone interface stress. At the L3-L4 level, compared with the other 2 models, the maximal values and dynamic response curves of intradiscal pressure, shear stress of annulus ground substance, and disc bulge were all lower in the ALIF model. However, the facet contact stress at the adjacent segment in the ALIF model was higher than that in the other 2 models. CONCLUSIONS In an osteoporotic spine under whole-body vibration, TLIF has the highest risk of screw and rod breakage, PLIF has the highest risk of cage subsidence, and ALIF has the lowest risk of upper adjacent disc degeneration, but the highest risk of adjacent facet joint degeneration.
Collapse
Affiliation(s)
- Qiuhong Zeng
- School of Chinese medicine, Jinan University, Guangzhou, China
| | - Yi Liao
- School of Chinese medicine, Jinan University, Guangzhou, China
| | - Kuokchon Pou
- School of Chinese medicine, Jinan University, Guangzhou, China
| | - Qian Chen
- School of Chinese medicine, Jinan University, Guangzhou, China
| | - Yixuan Li
- School of Chinese medicine, Jinan University, Guangzhou, China
| | - Lulu Cai
- School of Chinese medicine, Jinan University, Guangzhou, China
| | - Zhen Huang
- School of Chinese medicine, Jinan University, Guangzhou, China
| | - Shujie Tang
- School of Chinese medicine, Jinan University, Guangzhou, China.
| |
Collapse
|
6
|
Biomechanical and clinical studies on lumbar spine fusion surgery: a review. Med Biol Eng Comput 2023; 61:617-634. [PMID: 36598676 DOI: 10.1007/s11517-022-02750-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Accepted: 12/22/2022] [Indexed: 01/05/2023]
Abstract
Low back pain is associated with degenerative disc diseases of the spine. Surgical treatment includes fusion and non-fusion types. The gold standard is fusion surgery, wherein the affected vertebral segment is fused. The common complication of fusion surgery is adjacent segment degeneration (ASD). The ASD often leads to revision surgery, calling for a further fusion of adjacent segments. The existing designs of nonfusion type implants are associated with clinical problems such as subsidence, difficulty in implantation, and the requirement of revision surgeries. Various surgical approaches have been adopted by the surgeons to insert the spinal implants into the affected segment. Over the years, extensive biomechanical investigations have been reported on various surgical approaches and prostheses to predict the outcomes of lumbar spine implantations. Computer models have been proven to be very effective in identifying the best prosthesis and surgical procedure. The objective of the study was to review the literature on biomechanical studies for the treatment of lumbar spinal degenerative diseases. A critical review of the clinical and biomechanical studies on fusion spine surgeries was undertaken. The important modeling parameters, challenges, and limitations of the current studies were identified, showing the future research directions.
Collapse
|
7
|
Effect of Interbody Implants on the Biomechanical Behavior of Lateral Lumbar Interbody Fusion: A Finite Element Study. J Funct Biomater 2023; 14:jfb14020113. [PMID: 36826912 PMCID: PMC9962522 DOI: 10.3390/jfb14020113] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 01/30/2023] [Accepted: 02/10/2023] [Indexed: 02/22/2023] Open
Abstract
Porous titanium interbody scaffolds are growing in popularity due to their appealing advantages for bone ingrowth. This study aimed to investigate the biomechanical effects of scaffold materials in both normal and osteoporotic lumbar spines using a finite element (FE) model. Four scaffold materials were compared: Ti6Al4V (Ti), PEEK, porous titanium of 65% porosity (P65), and porous titanium of 80% porosity (P80). In addition, the range of motion (ROM), endplate stress, scaffold stress, and pedicle screw stress were calculated and compared. The results showed that the ROM decreased by more than 96% after surgery, and the solid Ti scaffold provided the lowest ROM (1.2-3.4% of the intact case) at the surgical segment among all models. Compared to solid Ti, PEEK decreased the scaffold stress by 53-66 and the endplate stress by 0-33%, while porous Ti decreased the scaffold stress by 20-32% and the endplate stress by 0-32%. Further, compared with P65, P80 slightly increased the ROM (<0.03°) and pedicle screw stress (<4%) and decreased the endplate stress by 0-13% and scaffold stress by approximately 18%. Moreover, the osteoporotic lumbar spine provided higher ROMs, endplate stresses, scaffold stresses, and pedicle screw stresses in all motion modes. The porous Ti scaffolds may offer an alternative for lateral lumbar interbody fusion.
Collapse
|
8
|
Wang R, Wu Z. Recent advancement in finite element analysis of spinal interbody cages: A review. Front Bioeng Biotechnol 2023; 11:1041973. [PMID: 37034256 PMCID: PMC10076720 DOI: 10.3389/fbioe.2023.1041973] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Accepted: 03/13/2023] [Indexed: 04/11/2023] Open
Abstract
Finite element analysis (FEA) is a widely used tool in a variety of industries and research endeavors. With its application to spine biomechanics, FEA has contributed to a better understanding of the spine, its components, and its behavior in physiological and pathological conditions, as well as assisting in the design and application of spinal instrumentation, particularly spinal interbody cages (ICs). IC is a highly effective instrumentation for achieving spinal fusion that has been used to treat a variety of spinal disorders, including degenerative disc disease, trauma, tumor reconstruction, and scoliosis. The application of FEA lets new designs be thoroughly "tested" before a cage is even manufactured, allowing bio-mechanical responses and spinal fusion processes that cannot easily be experimented upon in vivo to be examined and "diagnosis" to be performed, which is an important addition to clinical and in vitro experimental studies. This paper reviews the recent progress of FEA in spinal ICs over the last six years. It demonstrates how modeling can aid in evaluating the biomechanical response of cage materials, cage design, and fixation devices, understanding bone formation mechanisms, comparing the benefits of various fusion techniques, and investigating the impact of pathological structures. It also summarizes the various limitations brought about by modeling simplification and looks forward to the significant advancement of spine FEA research as computing efficiency and software capabilities increase. In conclusion, in such a fast-paced field, the FEA is critical for spinal IC studies. It helps in quantitatively and visually demonstrating the cage characteristics after implanting, lowering surgeons' learning costs for new cage products, and probably assisting them in determining the best IC for patients.
Collapse
Affiliation(s)
- Ruofan Wang
- Guangzhou Key Laboratory of Spine Disease Prevention and Treatment, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- Department of Orthopaedic Surgery, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
| | - Zenghui Wu
- Guangzhou Key Laboratory of Spine Disease Prevention and Treatment, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- Department of Orthopaedic Surgery, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- *Correspondence: Zenghui Wu,
| |
Collapse
|
9
|
Zhang Y, Zhou T, Gu Y, Che W, Zhang L, Wang Y. Contralateral bridge fixation of freehand minimally invasive pedicle screws combined with unilateral MIS-TLIF vs. open TLIF in the treatment of multi-segmental lumbar degenerative diseases: A five years retrospective study and finite element analysis. Front Surg 2022; 9:1049260. [DOI: 10.3389/fsurg.2022.1049260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Accepted: 10/14/2022] [Indexed: 11/06/2022] Open
Abstract
ObjectiveTo evaluate the efficacy, safety, feasibility and biomechanical stability of contralateral bridge fixation of freehand minimally invasive pedicle screws (Freehand MIPS) combined with unilateral minimally invasive surgery-transforaminal lumbar interbody fusion (MIS-TLIF) (smile-face surgery) and open TLIF for the treatment of multi-segmental lumbar degenerative diseases (LDDs).MethodsFrom January 2013 to January 2016, clinical data of multi-segmental (2- or 3-level) LDDs receiving smile-face surgery or open TLIF were retrospectively collected and analyzed. The back and leg pain VAS and ODI were used to assess clinical outcomes preoperatively and postoperatively. The MacNab criteria were used to evaluate the satisfaction of patient. The disc height (DH), lumbar lordosis (LL) and segmental lordosis angle (SLA) were measured before and after surgery. We used patient's CT data to establish the finite element model of smile-face surgery and open TLIF, and analyze biomechanical stability of two methods.ResultsSmile-face surgery group showed shorter operation time, shorter incision, less blood loss, shorter hospital stay than open TLIF (P < 0.05). The back VAS in smile-face surgery group was significantly lower than that in open TLIF immediately and 3 months after surgery, and no significant difference was observed 1 year, 2 years and 5 years after surgery. There was no significant difference in the leg pain VAS and ODI between both groups after surgery. No significant difference was observed between two groups in the DH, LL and SLA. At 5-year follow-up, grade I or II fusion was achieved in 99.00% (100/101) segments of smile-face surgery group and 97.67% (84/86) segments of open TLIF group according to Bridwell system. The complication rate of open TLIF was higher than that of smile-face surgery (24.32% vs. 0%, P < 0.01). After verification, the established finite element model can accurately simulate the biological structure of lumbar spine and there was no significant difference in biomechanical stability between two methods.ConclusionsSmile-face surgery has some advantages over open TLIF including smaller aggression, less blood loss, and lower cost, indicating that it is a good choice of treatment for multi-segmental LDDs. Both methods can achieve good biomechanical stability.
Collapse
|