1
|
Chen D, Motlagh SAO, Stappen FV, Labarbe R, Bell B, Kim M, Teo BKK, Dong L, Zou W, Diffenderfer ES. Secondary neutron dosimetry for conformal FLASH proton therapy. Med Phys 2024; 51:5081-5093. [PMID: 38597815 DOI: 10.1002/mp.17050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 03/12/2024] [Accepted: 03/13/2024] [Indexed: 04/11/2024] Open
Abstract
BACKGROUND Cyclotron-based proton therapy systems utilize the highest proton energies to achieve an ultra-high dose rate (UHDR) for FLASH radiotherapy. The deep-penetrating range associated with this high energy can be modulated by inserting a uniform plate of proton-stopping material, known as a range shifter, in the beam path at the nozzle to bring the Bragg peak within the target while ensuring high proton transport efficiency for UHDR. Aluminum has been recently proposed as a range shifter material mainly due to its high compactness and its mechanical properties. A possible drawback lies in the fact that aluminum has a larger cross-section of producing secondary neutrons compared to conventional plastic range shifters. Accordingly, an increase in secondary neutron contamination was expected during the delivery of range-modulated FLASH proton therapy, potentially heightening neutron-induced carcinogenic risks to the patient. PURPOSE We conducted neutron dosimetry using simulations and measurements to evaluate excess dose due to neutron exposure during UHDR proton irradiation with aluminum range shifters compared to plastic range shifters. METHODS Monte Carlo simulations in TOPAS were performed to investigate the secondary neutron production characteristics with aluminum range shifter during 225 MeV single-spot proton irradiation. The computational results were validated against measurements with a pair of ionization chambers in an out-of-field region ( ≤ $\le$ 30 cm) and with a Proton Recoil Scintillator-Los Alamos rem meter in a far-out-of-field region (0.5-2.5 m). The assessments were repeated with solid water slabs as a surrogate for the conventional range shifter material to evaluate the impact of aluminum on neutron yield. The results were compared with the International Electrotechnical Commission (IEC) standards to evaluate the clinical acceptance of the secondary neutron yield. RESULTS For a range modulation up to 26 cm in water, the maximum simulated and measured values of out-of-field secondary neutron dose equivalent per therapeutic dose with aluminum range shifter were found to be( 0.57 ± 0.02 ) mSv/Gy $(0.57\pm 0.02)\ \text{mSv/Gy}$ and( 0.46 ± 0.04 ) mSv/Gy $(0.46\pm 0.04)\ \text{mSv/Gy}$ , respectively, overall higher than the solid water cases (simulation:( 0.332 ± 0.003 ) mSv/Gy $(0.332\pm 0.003)\ \text{mSv/Gy}$ ; measurement:( 0.33 ± 0.03 ) mSv/Gy $(0.33\pm 0.03)\ \text{mSv/Gy}$ ). The maximum far out-of-field secondary neutron dose equivalent was found to be (8.8 ± 0.5 $8.8 \pm 0.5$ ) μ Sv / Gy $\umu {\rm Sv/Gy}$ and (1.62 ± 0.02 $1.62 \pm 0.02$ ) μ Sv / Gy $\umu {\rm Sv/Gy}$ for the simulations and rem meter measurements, respectively, also higher than the solid water counterparts (simulation: (3.3 ± 0.3 $3.3 \pm 0.3$ ) μ Sv / Gy $\umu {\rm Sv/Gy}$ ; measurement: (0.63 ± 0.03 $0.63 \pm 0.03$ ) μ Sv / Gy $\umu {\rm Sv/Gy}$ ). CONCLUSIONS We conducted simulations and measurements of secondary neutron production under proton irradiation at FLASH energy with range shifters. We found that the secondary neutron yield increased when using aluminum range shifters compared to conventional materials while remaining well below the non-primary radiation limit constrained by the IEC regulations.
Collapse
Affiliation(s)
- Dixin Chen
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | | | | | - Rudi Labarbe
- Ion Beam Applications S.A. (IBA), Louvain-la-Neuve, Belgium
| | - Beryl Bell
- Ion Beam Applications S.A. (IBA), Louvain-la-Neuve, Belgium
| | - Michele Kim
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Boon-Keng Kevin Teo
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Lei Dong
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Wei Zou
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | | |
Collapse
|
2
|
Wulff J, Paul A, Bäcker CM, Baumann KS, Esser JN, Koska B, Timmermann B, Verbeek NG, Bäumer C. Consistency of Faraday cup and ionization chamber dosimetry of proton fields and the role of nuclear interactions. Med Phys 2024; 51:2277-2292. [PMID: 37991110 DOI: 10.1002/mp.16819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 09/21/2023] [Accepted: 09/28/2023] [Indexed: 11/23/2023] Open
Abstract
BACKGROUND A Faraday cup (FC) facilitates a quite clean measurement of the proton fluence emerging from clinical spot-scanning nozzles with narrow pencil-beams. The utilization of FCs appears to be an attractive option for high dose rate delivery modes and the source models of Monte-Carlo (MC) dose engines. However, previous studies revealed discrepancies of 3%-6% between reference dosimetry with ionization chambers (ICs) and FC-based dosimetry. This has prevented the widespread use of FCs for dosimetry in proton therapy. PURPOSE The current study aims at bridging the gap between FC dosimetry and IC dosimetry of proton fields delivered with spot-scanning treatment heads. Particularly, a novel method to evaluate FC measurements is introduced. METHODS A consistency check is formulated, which makes use of the energy balance and the reciprocity theorem. The measurement data comprise central-axis depth distributions of the absorbed dose of quasi-monochromatic fields with a width of about 28.5 cm and FC measurements of the reciprocal fields with a single spot. These data are complemented by a look-up of energy-range tables, the average Q-value of transmutations, and the escape energy carried away by neutrons and photons. The latter data are computed by MC simulations, which in turn are validated with measurements of the distal dose tail and neutron out-of-field doses. For comparison, the conventional approach of FC evaluation is performed, which computes absorbed dose from the product of fluence and stopping power. The results from the FC measurements are compared with the standard dosimetry protocols and improved reference dosimetry methods. RESULTS The deviation between the conventional FC-based dosimetry and the IC-based one according to standard dosimetry protocols was -4.7 ( ± $\pm$ 3.3)% for a 100 MeV field and -3.6 ( ± $\pm$ 3.5)% for 200 MeV, thereby agreeing within the reported uncertainties. The deviations could be reduced to -4.0 ( ± $\pm$ 2.9)% and -3.0 ( ± $\pm$ 3.1)% by adopting state-of-the-art reference dosimetry methods. The alternative approach using the energy balance gave deviations of only -1.9% (100 MeV) and -2.6% (200 MeV) using state-of-the-art dosimetry. The standard uncertainty of this novel approach was estimated to be about 2%. CONCLUSIONS An alternative concept has been established to determine the absorbed dose of monoenergetic proton fields with an FC. It eliminates the strong dependence of the conventional FC-based approach on the MC simulation of the stopping-power and of the secondary ions, which according to the study at hand is the major contributor to the underestimation of the absorbed dose. Some contributions to the uncertainty of the novel approach could potentially be reduced in future studies. This would allow for accurate consistency tests of conventional dosimetry procedures.
Collapse
Affiliation(s)
- Jörg Wulff
- West German Proton Therapy Centre Essen, Essen, Germany
- University Hospital Essen, Essen, Germany
- West German Cancer Center (WTZ), Essen, Germany
| | - Anne Paul
- West German Proton Therapy Centre Essen, Essen, Germany
- University Hospital Essen, Essen, Germany
- West German Cancer Center (WTZ), Essen, Germany
- Heinrich Heine University Düsseldorf, Düsseldorf, Germany
| | - Claus Maximilian Bäcker
- West German Proton Therapy Centre Essen, Essen, Germany
- University Hospital Essen, Essen, Germany
- West German Cancer Center (WTZ), Essen, Germany
| | - Kilian-Simon Baumann
- Department of Radiotherapy and Radiation Oncology, Marburg University Hospital, Marburg, Germany
- Marburg Ion-Beam Therapy Center (MIT), Marburg, Germany
- University of Applied Sciences, Institute of Medical Physics and Radiation Protection, Giessen, Germany
| | - Johannes Niklas Esser
- West German Proton Therapy Centre Essen, Essen, Germany
- University Hospital Essen, Essen, Germany
- West German Cancer Center (WTZ), Essen, Germany
| | - Benjamin Koska
- West German Proton Therapy Centre Essen, Essen, Germany
- University Hospital Essen, Essen, Germany
- West German Cancer Center (WTZ), Essen, Germany
| | - Beate Timmermann
- West German Proton Therapy Centre Essen, Essen, Germany
- University Hospital Essen, Essen, Germany
- West German Cancer Center (WTZ), Essen, Germany
- Heinrich Heine University Düsseldorf, Düsseldorf, Germany
- German Cancer Consortium (DKTK), Essen, Germany
- Department of Particle Therapy, University Hospital Essen, Essen, Germany
| | - Nico Gerd Verbeek
- West German Proton Therapy Centre Essen, Essen, Germany
- University Hospital Essen, Essen, Germany
- West German Cancer Center (WTZ), Essen, Germany
| | - Christian Bäumer
- West German Proton Therapy Centre Essen, Essen, Germany
- University Hospital Essen, Essen, Germany
- West German Cancer Center (WTZ), Essen, Germany
- German Cancer Consortium (DKTK), Essen, Germany
- Department of Physics, Technische Universität Dortmund, Dortmund, Germany
| |
Collapse
|
3
|
Geser FA, Stabilini A, Christensen JB, Muñoz ID, Yukihara EG, Jäkel O, Vedelago J. A Monte Carlo study on the secondary neutron generation by oxygen ion beams for radiotherapy and its comparison to lighter ions. Phys Med Biol 2024; 69:015027. [PMID: 37995363 DOI: 10.1088/1361-6560/ad0f45] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Accepted: 11/23/2023] [Indexed: 11/25/2023]
Abstract
Objective.To study the secondary neutrons generated by primary oxygen beams for cancer treatment and compare the results to those from primary protons, helium, and carbon ions. This information can provide useful insight into the positioning of neutron detectors in phantom for future experimental dose assessments.Approach.Mono-energetic oxygen beams and spread-out Bragg peaks were simulated using the Monte Carlo particle transport codesFLUktuierende KAskade, tool for particle simulation, and Monte Carlo N-Particle, with energies within the therapeutic range. The energy and angular distribution of the secondary neutrons were quantified.Main results.The secondary neutron spectra generated by primary oxygen beams present the same qualitative trend as for other primary ions. The energy distributions resemble continuous spectra with one peak in the thermal/epithermal region, and one other peak in the fast/relativistic region, with the most probable energy ranging from 94 up to 277 MeV and maximum energies exceeding 500 MeV. The angular distribution of the secondary neutrons is mainly downstream-directed for the fast/relativistic energies, whereas the thermal/epithermal neutrons present a more isotropic propagation. When comparing the four different primary ions, there is a significant increase in the most probable energy as well as the number of secondary neutrons per primary particle when increasing the mass of the primaries.Significance.Most previous studies have only presented results of secondary neutrons generated by primary proton beams. In this work, secondary neutrons generated by primary oxygen beams are presented, and the obtained energy and angular spectra are added as supplementary material. Furthermore, a comparison of the secondary neutron generation by the different primary ions is given, which can be used as the starting point for future studies on treatment plan comparison and secondary neutron dose optimisation. The distal penumbra after the maximum dose deposition appears to be a suitable location for in-phantom dose assessments.
Collapse
Affiliation(s)
- Federico A Geser
- Department of Radiation Safety and Security, Paul Scherrer Institute (PSI), Forschungsstrasse 111, Villigen PSI 5232, Switzerland
| | - Alberto Stabilini
- Department of Radiation Safety and Security, Paul Scherrer Institute (PSI), Forschungsstrasse 111, Villigen PSI 5232, Switzerland
| | - Jeppe B Christensen
- Department of Radiation Safety and Security, Paul Scherrer Institute (PSI), Forschungsstrasse 111, Villigen PSI 5232, Switzerland
| | - Iván D Muñoz
- Department of Physics and Astronomy, Heidelberg University, Im Neuenheimer Feld 226, Heidelberg D-69120, Germany
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| | - Eduardo G Yukihara
- Department of Radiation Safety and Security, Paul Scherrer Institute (PSI), Forschungsstrasse 111, Villigen PSI 5232, Switzerland
| | - Oliver Jäkel
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- Heidelberg Ion Beam Therapy Center (HIT), Department of Radiation Oncology, University Hospital Heidelberg (UKHD), Im Neuenheimer Feld 450, Heidelberg D-69120, Germany
| | - José Vedelago
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- Department of Radiation Oncology, Heidelberg University Hospital (UKHD), Im Neuenheimer Feld 400, Heidelberg D-69120, Germany
| |
Collapse
|
4
|
Tjelta J, Fjæra LF, Ytre-Hauge KS, Boer CG, Stokkevåg CH. A systematic approach for calibrating a Monte Carlo code to a treatment planning system for obtaining dose, LET, variable proton RBE and out-of-field dose. Phys Med Biol 2023; 68:225010. [PMID: 37820690 DOI: 10.1088/1361-6560/ad0281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Accepted: 10/11/2023] [Indexed: 10/13/2023]
Abstract
Objective. While integration of variable relative biological effectiveness (RBE) has not reached full clinical implementation, the importance of having the ability to recalculate proton treatment plans in a flexible, dedicated Monte Carlo (MC) code cannot be understated . Here we provide a step-wise method for calibrating dose from a MC code to a treatment planning system (TPS), to obtain required parameters for calculating linear energy transfer (LET), variable RBE and in general enabling clinical realistic research studies beyond the capabilities of a TPS.Approach. Initially, Pristine Bragg peaks (PBP) were calculated in both the Eclipse TPS and the FLUKA MC code. A rearranged Bortfeld energy-range relation was applied to the initial energy of the beam to fine-tune the range of the MC code at 80% dose level distal to the PBP. The energy spread was adapted by dividing the TPS range by the MC range for dose level 80%-20% distal to the PBP. Density and relative proton stopping power were adjusted by comparing the TPS and MC for different Hounsfield units. To find the relationship of dose per primary particle from the MC to dose per monitor unit in the TPS, integration was applied to the area of the Bragg curve. The calibration was validated for spread-out Bragg peaks (SOBP) in water and patient treatment plans. Following the validation, variable RBE were calculated using established models.Main results.The PBPs ranges were within ±0.3mm threshold, and a maximum of 5.5% difference for the SOBPs was observed. The patient validation showed excellent dose agreement between the TPS and MC, with the greatest differences for the lung tumor patient.Significance. Aprocedure for calibrating a MC code to a TPS was developed and validated. The procedure enables MC-based calculation of dose, LET, variable RBE, advanced (secondary) particle tracking and more from treatment plans.
Collapse
Affiliation(s)
- Johannes Tjelta
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| | - Lars Fredrik Fjæra
- Department of Physics and Technology, University of Bergen, Bergen, Norway
- Department of Oncology and Medical Physics, Oslo University Hospital, Oslo, Norway
| | | | | | - Camilla Hanquist Stokkevåg
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| |
Collapse
|
5
|
Tjelta J, Ytre-Hauge K, Lyngholm E, Handeland A, Henjum H, Stokkevåg C. Dose exposure to an adult present in the treatment room during pediatric pencil beam scanning proton therapy. Acta Oncol 2023; 62:1531-1535. [PMID: 37676843 DOI: 10.1080/0284186x.2023.2254924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Accepted: 08/29/2023] [Indexed: 09/09/2023]
Affiliation(s)
- Johannes Tjelta
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| | | | - Erlend Lyngholm
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| | - Andreas Handeland
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| | - Helge Henjum
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| | - Camilla Stokkevåg
- Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway
- Department of Physics and Technology, University of Bergen, Bergen, Norway
| |
Collapse
|
6
|
Colson D, Blommaert J, Poels K, De Saint-Hubert M, Reniers B, Depuydt T. Extended in-field and out-of-field validation of a compact Monte Carlo model of an IBA PROTEUS ®ONE proton beam in TOPAS/GEANT4. Phys Med Biol 2023; 68:21NT02. [PMID: 37844576 DOI: 10.1088/1361-6560/ad03a9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 10/16/2023] [Indexed: 10/18/2023]
Abstract
Objective:This study evaluates a compact Monte Carlo (MC) model of a pencil beam scanning clinical proton beam using TOPAS to estimate the dose out-of-field (OOF). Compact modelling means that the model starts from a pristine proton beam at the nozzle exit, customised based on acceptance and commissioning data, instead of modelling the full treatment head and room.Approach: First, in-field validation tests were performed. Then, the OOF dose was validated in an RW3 phantom with bubble detectors for personal neutron dosimetry (measuring the neutron dose equivalent) and thermoluminiescent detectors (measuring the absorbed dose by protons and gammas). Measurements were performed at 15 and 35 cm from the distal edge of the field for five different irradiation plans, covering different beam orientations, proton energies and a 40 mm range shifter. TOPAS simulations were performed with QGSP Binary Cascade HP (BIC) and QGSP Bertini HP (Bertini) hadron physics lists.Main results: In-field validation shows that MC simulations agree with point dose measurements within -2.5 % and +1.5 % at locations on- and off-axis and before, in and after the Bragg peak or plateau. The gamma passing rate 2%/3mm of four simulated treatment plans compared to the dose distribution calculated by the TPS exceeds 97 % agreement score. OOF dose simulations showed an average overestimation of 27 % of the neutron dose equivalent for the BIC hadron physics list and an average underestimation of 20 % for the Bertini hadron physics list. The simulated absorbed dose of protons and gammas showed a systematic underestimation which was on average 21 % and 51 % for BIC and Bertini respectively.Significance: Our study demonstrates that a compact MC model can reliably produce in-field data, while out-of-field dose data are within the uncertainties of the detector systems and MC simulations nuclear models, and do so with shorter modelling and faster calculation time.
Collapse
Affiliation(s)
- Dries Colson
- Hasselt University, Faculty of Engineering Technology - Nuclear Technology (NuTeC), Hasselt, Belgium
| | | | - Kenneth Poels
- University Hospitals Leuven, Department of Radiation Oncology, Leuven, Belgium
| | - Marijke De Saint-Hubert
- Belgian Nuclear Research Centre (SCK CEN), Research in Dosimetric Applications, Mol, Belgium
| | - Brigitte Reniers
- Hasselt University, Faculty of Engineering Technology - Nuclear Technology (NuTeC), Hasselt, Belgium
| | - Tom Depuydt
- KU Leuven, department of Oncology, Leuven, Belgium
- University Hospitals Leuven, Department of Radiation Oncology, Leuven, Belgium
| |
Collapse
|
7
|
Borja-Lloret M, Barrientos L, Bernabéu J, Lacasta C, Muñoz E, Ros A, Roser J, Viegas R, Llosá G. Influence of the background in Compton camera images for proton therapy treatment monitoring. Phys Med Biol 2023; 68:144001. [PMID: 37339665 DOI: 10.1088/1361-6560/ace024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 06/20/2023] [Indexed: 06/22/2023]
Abstract
Objective. Background events are one of the most relevant contributions to image degradation in Compton camera imaging for hadron therapy treatment monitoring. A study of the background and its contribution to image degradation is important to define future strategies to reduce the background in the system.Approach. In this simulation study, the percentage of different kinds of events and their contribution to the reconstructed image in a two-layer Compton camera have been evaluated. To this end, GATE v8.2 simulations of a proton beam impinging on a PMMA phantom have been carried out, for different proton beam energies and at different beam intensities.Main results. For a simulated Compton camera made of Lanthanum (III) Bromide monolithic crystals, coincidences caused by neutrons arriving from the phantom are the most common type of background produced by secondary radiations in the Compton camera, causing between 13% and 33% of the detected coincidences, depending on the beam energy. Results also show that random coincidences are a significant cause of image degradation at high beam intensities, and their influence in the reconstructed images is studied for values of the time coincidence windows from 500 ps to 100 ns.Significance. Results indicate the timing capabilities required to retrieve the fall-off position with good precision. Still, the noise observed in the image when no randoms are considered make us consider further background rejection methods.
Collapse
Affiliation(s)
- M Borja-Lloret
- Institut de Física Corpuscular (IFIC), CSIC-UV, València, Spain
| | - L Barrientos
- Institut de Física Corpuscular (IFIC), CSIC-UV, València, Spain
| | - J Bernabéu
- Institut de Física Corpuscular (IFIC), CSIC-UV, València, Spain
| | - C Lacasta
- Institut de Física Corpuscular (IFIC), CSIC-UV, València, Spain
| | - E Muñoz
- Institut de Física Corpuscular (IFIC), CSIC-UV, València, Spain
| | - A Ros
- Institut de Física Corpuscular (IFIC), CSIC-UV, València, Spain
| | - J Roser
- Institut de Física Corpuscular (IFIC), CSIC-UV, València, Spain
| | - R Viegas
- Institut de Física Corpuscular (IFIC), CSIC-UV, València, Spain
| | - G Llosá
- Institut de Física Corpuscular (IFIC), CSIC-UV, València, Spain
| |
Collapse
|
8
|
Schnelzauer L, Valentin S, Traykov E, Arbor N, Finck C, Vanstalle M. Short-lived radioactive 8Li and 8He ions for hadrontherapy: a simulation study. Phys Med Biol 2023; 68. [PMID: 36731132 DOI: 10.1088/1361-6560/acb88b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Accepted: 02/02/2023] [Indexed: 02/04/2023]
Abstract
Purpose.Although charged particle therapy (CPT) for cancer treatment has grown these past years, the use of protons and carbon ions for therapy remains debated compared to x-ray therapy. While a biological advantage of protons is not clearly demonstrated, therapy using carbon ions is often pointed out for its high cost. Furthermore, the nuclear interactions undergone by carbons inside the patient are responsible for an additional dose delivered after the Bragg peak, which deteriorates the ballistic advantage of CPT. Therefore, a renewed interest for lighter ions with higher biological efficiency than protons was recently observed. In this context, helium and lithium ions represent a good compromise between protons and carbons, as they exhibit a higher linear energy transfer (LET) than protons in the Bragg peak and can be accelerated by cyclotrons. The possibility of accelerating radioactive8Li, decaying in 2α-particles, and8He, decaying in8Li byβ-decay, is particularly interesting.Methods. This work aims to assess the interest of the use of8Li and8He ions for therapy by Monte Carlo simulations carried out withGeant4.Results. It was calculated that the8Li and8He decay results in an increase of the LET of almost a factor 2 in the Bragg peak compared to stable7Li and4He. This results also in a higher dose deposited in the Bragg peak without an increase of the dose in the plateau region. It was also shown that both8He and8Li can have a potential interest for prompt-gamma monitoring techniques. Finally, the feasibility of accelerating facilities delivering8Li and8He was also discussed.Conclusion. In this study, we demonstrate that both8Li and8He have interesting properties for therapy. Indeed, simulations predict that8Li and8He are a good compromise between proton and12C, both in terms of LET and dose.
Collapse
Affiliation(s)
- L Schnelzauer
- Université de Strasbourg, CNRS, IPHC UMR 7871, F-67000 STRASBOURG, France
| | - S Valentin
- Université de Strasbourg, CNRS, IPHC UMR 7871, F-67000 STRASBOURG, France
| | - E Traykov
- Université de Strasbourg, CNRS, IPHC UMR 7871, F-67000 STRASBOURG, France
| | - N Arbor
- Université de Strasbourg, CNRS, IPHC UMR 7871, F-67000 STRASBOURG, France
| | - Ch Finck
- Université de Strasbourg, CNRS, IPHC UMR 7871, F-67000 STRASBOURG, France
| | - M Vanstalle
- Université de Strasbourg, CNRS, IPHC UMR 7871, F-67000 STRASBOURG, France
| |
Collapse
|
9
|
García-Baonza R, Murcia-Morales A, Gallego E. Comparison of PHITS2.88 and MCNP6.1 for the characterization of a LUPIN-II neutron area monitor. Appl Radiat Isot 2022; 188:110407. [PMID: 35970118 DOI: 10.1016/j.apradiso.2022.110407] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 07/20/2022] [Accepted: 08/04/2022] [Indexed: 11/02/2022]
Abstract
The use of different nuclear data libraries and physics models can be a source of discrepancies in neutron transport simulation. Different Monte Carlo simulation toolkits can be used to characterize neutron monitors, these codes usually employ by default different nuclear data libraries and physics models. This work presents, for the first time, a comparison of MCNP and PHITS for the characterization of a LUPIN-II neutron rem-meter. The most significant discrepancies between the codes have been found around 100 MeV.
Collapse
Affiliation(s)
- Roberto García-Baonza
- Departamento de Ingeniería Energética, ETSI Industriales, Universidad Politécnica de Madrid, José Gutiérrez Abascal 2, 28006, Madrid, Spain.
| | - Adrián Murcia-Morales
- Departamento de Ingeniería Energética, ETSI Industriales, Universidad Politécnica de Madrid, José Gutiérrez Abascal 2, 28006, Madrid, Spain
| | - Eduardo Gallego
- Departamento de Ingeniería Energética, ETSI Industriales, Universidad Politécnica de Madrid, José Gutiérrez Abascal 2, 28006, Madrid, Spain
| |
Collapse
|
10
|
Kollitz E, Roew M, Han H, Pinto M, Kamp F, Kim CH, Schwarz M, Belka C, Newhauser W, Parodi K, Dedes G. Applications of a patient-specific whole-body CT-mesh hybrid computational phantom in second cancer risk prediction. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac8851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Accepted: 08/09/2022] [Indexed: 11/11/2022]
Abstract
Abstract
Objective. CT-mesh hybrid phantoms (or ‘hybrid(s)’) made from integrated patient CT data and mesh-type reference computational phantoms (MRCPs) can be beneficial for patient-specific whole-body dose evaluation, but this benefit has yet to be evaluated for second cancer risk prediction. The purpose of this study is to compare the hybrid’s ability to predict risk throughout the body with a patient-scaled MRCP against ground truth whole-body CTs (WBCTs). Approach. Head and neck active scanning proton treatment plans were created for and simulated on seven hybrids and the corresponding scaled MRCPs and WBCTs. Equivalent dose throughout the body was calculated and input into five second cancer risk models for both excess absolute and excess relative risk (EAR and ERR). The hybrid phantom was evaluated by comparing equivalent dose and risk predictions against the WBCT. Main results. The hybrid most frequently provides whole-body second cancer risk predictions which are closer to the ground truth when compared to a scaled MRCP alone. The performance of the hybrid relative to the scaled MRCP was consistent across ERR, EAR, and all risk models. For all in-field organs, where the hybrid shares the WBCT anatomy, the hybrid was better than or equal to the scaled MRCP for both equivalent dose and risk prediction. For out-of-field organs across all patients, the hybrid’s equivalent dose prediction was superior than the scaled MRCP in 48% of all comparisons, equivalent for 34%, and inferior for 18%. For risk assessment in the same organs, the hybrid’s prediction was superior than the scaled MRCP in 51.8% of all comparisons, equivalent in 28.6%, and inferior in 19.6%. Significance. Whole-body risk predictions from the CT-mesh hybrid have shown to be more accurate than those from a reference phantom alone. These hybrids could aid in risk-optimized treatment planning and individual risk assessment to minimize second cancer incidence.
Collapse
|
11
|
Van Hoey O, Stolarczyk L, Lillhök J, Eliasson L, Mojzeszek N, Liszka M, Alkhiat A, Mares V, Trompier F, Trinkl S, Martínez-Rovira I, Romero-Expósito M, Domingo C, Ploc O, Harrison R, Olko P. Simulation and experimental verification of ambient neutron doses in a pencil beam scanning proton therapy room as a function of treatment plan parameters. Front Oncol 2022; 12:903537. [PMID: 36158693 PMCID: PMC9494550 DOI: 10.3389/fonc.2022.903537] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Accepted: 07/07/2022] [Indexed: 11/23/2022] Open
Abstract
Out-of-field patient doses in proton therapy are dominated by neutrons. Currently, they are not taken into account by treatment planning systems. There is an increasing need to include out-of-field doses in the dose calculation, especially when treating children, pregnant patients, and patients with implants. In response to this demand, this work presents the first steps towards a tool for the prediction of out-of-field neutron doses in pencil beam scanning proton therapy facilities. As a first step, a general Monte Carlo radiation transport model for simulation of out-of-field neutron doses was set up and successfully verified by comparison of simulated and measured ambient neutron dose equivalent and neutron fluence energy spectra around a solid water phantom irradiated with a variation of different treatment plan parameters. Simulations with the verified model enabled a detailed study of the variation of the neutron ambient dose equivalent with field size, range, modulation width, use of a range shifter, and position inside the treatment room. For future work, it is planned to use this verified model to simulate out-of-field neutron doses inside the phantom and to verify the simulation results by comparison with previous in-phantom measurement campaigns. Eventually, these verified simulations will be used to build a library and a corresponding tool to allow assessment of out-of-field neutron doses at pencil beam scanning proton therapy facilities.
Collapse
Affiliation(s)
- Olivier Van Hoey
- Belgian Nuclear Research Center (SCK CEN), Institute for Environment, Health and Safety (EHS), Mol, Belgium
- *Correspondence: Olivier Van Hoey,
| | - Liliana Stolarczyk
- Danish Centre for Particle Therapy, Aarhus University Hospital (AUH), Aarhus, Denmark
- Institute of Nuclear Physics, Polish Academy of Sciences, (IFJ PAN), Krakow, Poland
- The Skandion Clinic, Uppsala, Sweden
| | - Jan Lillhök
- Swedish Radiation Safety Authority, Solna, Sweden
| | - Linda Eliasson
- Department of Physics, Royal Institute of Technology (KTH), Stockholm, Sweden
| | - Natalia Mojzeszek
- Institute of Nuclear Physics, Polish Academy of Sciences, (IFJ PAN), Krakow, Poland
| | - Malgorzata Liszka
- Institute of Nuclear Physics, Polish Academy of Sciences, (IFJ PAN), Krakow, Poland
- The Skandion Clinic, Uppsala, Sweden
| | - Ali Alkhiat
- The Skandion Clinic, Uppsala, Sweden
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden
| | - Vladimir Mares
- Helmholtz Zentrum München, Institute of Radiation Medicine, Neuherberg, Germany
| | - François Trompier
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSE-Santé, Fontenay-aux-Roses, France
| | - Sebastian Trinkl
- Helmholtz Zentrum München, Institute of Radiation Medicine, Neuherberg, Germany
- Federal Office for Radiation Protection, Neuherberg, Germany
| | | | | | - Carles Domingo
- Departament de Física, Universitat Autònoma de Barcelona, Bellaterra, Spain
| | - Ondrej Ploc
- Department of Radiation Dosimetry, Nuclear Physics Institute of the Czech Academy of Sciences (CAS), Prague, Czechia
| | - Roger Harrison
- Faculty of Medical Sciences, University of Newcastle upon Tyne, Newcastle Upon Tyne, United Kingdom
| | - Pawel Olko
- Institute of Nuclear Physics, Polish Academy of Sciences, (IFJ PAN), Krakow, Poland
| |
Collapse
|
12
|
Vedelago J, Karger CP, Jäkel O. A review on reference dosimetry in radiation therapy with proton and light ion beams: status and impact of new developments. RADIAT MEAS 2022. [DOI: 10.1016/j.radmeas.2022.106844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
|
13
|
De Saint-Hubert M, Verbeek N, Bäumer C, Esser J, Wulff J, Nabha R, Van Hoey O, Dabin J, Stuckmann F, Vasi F, Radonic S, Boissonnat G, Schneider U, Rodriguez M, Timmermann B, Thierry-Chef I, Brualla L. Validation of a Monte Carlo Framework for Out-of-Field Dose Calculations in Proton Therapy. Front Oncol 2022; 12:882489. [PMID: 35756661 PMCID: PMC9213663 DOI: 10.3389/fonc.2022.882489] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 05/04/2022] [Indexed: 11/30/2022] Open
Abstract
Proton therapy enables to deliver highly conformed dose distributions owing to the characteristic Bragg peak and the finite range of protons. However, during proton therapy, secondary neutrons are created, which can travel long distances and deposit dose in out-of-field volumes. This out-of-field absorbed dose needs to be considered for radiation-induced secondary cancers, which are particularly relevant in the case of pediatric treatments. Unfortunately, no method exists in clinics for the computation of the out-of-field dose distributions in proton therapy. To help overcome this limitation, a computational tool has been developed based on the Monte Carlo code TOPAS. The purpose of this work is to evaluate the accuracy of this tool in comparison to experimental data obtained from an anthropomorphic phantom irradiation. An anthropomorphic phantom of a 5-year-old child (ATOM, CIRS) was irradiated for a brain tumor treatment in an IBA Proteus Plus facility using a pencil beam dedicated nozzle. The treatment consisted of three pencil beam scanning fields employing a lucite range shifter. Proton energies ranged from 100 to 165 MeV. A median dose of 50.4 Gy(RBE) with 1.8 Gy(RBE) per fraction was prescribed to the initial planning target volume (PTV), which was located in the cerebellum. Thermoluminescent detectors (TLDs), namely, Li-7-enriched LiF : Mg, Ti (MTS-7) type, were used to detect gamma radiation, which is produced by nuclear reactions, and secondary as well as recoil protons created out-of-field by secondary neutrons. Li-6-enriched LiF : Mg,Cu,P (MCP-6) was combined with Li-7-enriched MCP-7 to measure thermal neutrons. TLDs were calibrated in Co-60 and reported on absorbed dose in water per target dose (μGy/Gy) as well as thermal neutron dose equivalent per target dose (μSv/Gy). Additionally, bubble detectors for personal neutron dosimetry (BD-PND) were used for measuring neutrons (>50 keV), which were calibrated in a Cf-252 neutron beam to report on neutron dose equivalent dose data. The Monte Carlo code TOPAS (version 3.6) was run using a phase-space file containing 1010 histories reaching an average standard statistical uncertainty of less than 0.2% (coverage factor k = 1) on all voxels scoring more than 50% of the maximum dose. The primary beam was modeled following a Fermi–Eyges description of the spot envelope fitted to measurements. For the Monte Carlo simulation, the chemical composition of the tissues represented in ATOM was employed. The dose was tallied as dose-to-water, and data were normalized to the target dose (physical dose) to report on absorbed doses per target dose (mSv/Gy) or neutron dose equivalent per target dose (μSv/Gy), while also an estimate of the total organ dose was provided for a target dose of 50.4 Gy(RBE). Out-of-field doses showed absorbed doses that were 5 to 6 orders of magnitude lower than the target dose. The discrepancy between TLD data and the corresponding scored values in the Monte Carlo calculations involving proton and gamma contributions was on average 18%. The comparison between the neutron equivalent doses between the Monte Carlo simulation and the measured neutron doses was on average 8%. Organ dose calculations revealed the highest dose for the thyroid, which was 120 mSv, while other organ doses ranged from 18 mSv in the lungs to 0.6 mSv in the testes. The proposed computational method for routine calculation of the out-of-the-field dose in proton therapy produces results that are compatible with the experimental data and allow to calculate out-of-field organ doses during proton therapy.
Collapse
Affiliation(s)
- Marijke De Saint-Hubert
- Research in Dosimetric Applications, Belgian Nuclear Research Center (SCK CEN), Mol, Belgium
| | - Nico Verbeek
- West German Proton Therapy Centre Essen WPE, Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany.,Faculty of Medicine, University of Duisburg-Essen, Essen, Germany
| | - Christian Bäumer
- West German Proton Therapy Centre Essen WPE, Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany.,Radiation Oncology and Imaging, German Cancer Consortium DKTK, Heidelberg, Germany.,Department of Physics, TU Dortmund University, Dortmund, Germany
| | - Johannes Esser
- West German Proton Therapy Centre Essen WPE, Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany.,Faculty of Mathematics and Science Institute of Physics and Medical Physics. Heinrich-Heine University, Düsseldorf, Germany
| | - Jörg Wulff
- West German Proton Therapy Centre Essen WPE, Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany
| | - Racell Nabha
- Research in Dosimetric Applications, Belgian Nuclear Research Center (SCK CEN), Mol, Belgium
| | - Olivier Van Hoey
- Research in Dosimetric Applications, Belgian Nuclear Research Center (SCK CEN), Mol, Belgium
| | - Jérémie Dabin
- Research in Dosimetric Applications, Belgian Nuclear Research Center (SCK CEN), Mol, Belgium
| | - Florian Stuckmann
- West German Proton Therapy Centre Essen WPE, Essen, Germany.,Faculty of Mathematics and Science Institute of Physics and Medical Physics. Heinrich-Heine University, Düsseldorf, Germany.,Klinikum Fulda GAG, Universitätsmedizin Marburg, Fulda, Zurich, Germany
| | - Fabiano Vasi
- Physik Institut, Universität Zürich, Zürich, Switzerland
| | | | | | - Uwe Schneider
- Physik Institut, Universität Zürich, Zürich, Switzerland
| | - Miguel Rodriguez
- Hospital Paitilla, Panama City, Panama.,Instituto de Investigaciones Cientificas y de Alta Tecnología INDICASAT-AIP, Panama City, Panama
| | - Beate Timmermann
- West German Proton Therapy Centre Essen WPE, Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany.,Faculty of Medicine, University of Duisburg-Essen, Essen, Germany.,Radiation Oncology and Imaging, German Cancer Consortium DKTK, Heidelberg, Germany.,Department of Particle Therapy, University Hospital Essen, Essen, Germany
| | - Isabelle Thierry-Chef
- Radiation Programme, Barcelona Institute for Global Health (ISGlobal), Barcelona, Spain.,University Pompeu Fabra, Barcelona, Spain.,CIBER Epidemiología y Salud Pública, Madrid, Spain
| | - Lorenzo Brualla
- West German Proton Therapy Centre Essen WPE, Essen, Germany.,West German Cancer Center (WTZ), Essen, Germany.,Faculty of Medicine, University of Duisburg-Essen, Essen, Germany
| |
Collapse
|
14
|
Becker A, Jäkel O, Vedelago J. Intensity threshold variation method in the post-irradiation analysis of Fluorescent Nuclear Track Detectors for neutron dosimetry. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
15
|
The influence of nuclear models and Monte Carlo radiation transport codes on stray neutron dose estimations in proton therapy. RADIAT MEAS 2022. [DOI: 10.1016/j.radmeas.2021.106693] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
16
|
Kollitz E, Han H, Kim CH, Pinto M, Schwarz M, Riboldi M, Kamp F, Belka C, Newhauser WD, Dedes G, Parodi K. A patient-specific hybrid phantom for calculating radiation dose and equivalent dose to the whole body. Phys Med Biol 2021; 67. [PMID: 34969024 DOI: 10.1088/1361-6560/ac4738] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Accepted: 12/30/2021] [Indexed: 11/12/2022]
Abstract
OBJECTIVE As cancer survivorship increases, there is growing interest in minimizing the late effects of radiation therapy such as radiogenic second cancer, which may occur anywhere in the body. Assessing the risk of late effects requires knowledge of the dose distribution throughout the whole body, including regions far from the treatment field, beyond the typical anatomical extent of clinical CT scans. APPROACH A hybrid phantom was developed which consists of in-field patient CT images extracted from ground truth whole-body CT (WBCT) scans, out-of-field mesh phantoms scaled to basic patient measurements, and a blended transition region. Four of these hybrid phantoms were created, representing male and female patients receiving proton therapy treatment in pelvic and cranial sites. To assess the performance of the hybrid approach, we simulated treatments using the hybrid phantoms, the scaled and unscaled mesh phantoms, and the ground truth whole-body CTs. We calculated absorbed dose and equivalent dose in and outside of the treatment field, with a focus on neutrons induced in the patient by proton therapy. Proton and neutron dose was calculated using a general purpose Monte Carlo code. MAIN RESULTS The hybrid phantom provided equal or superior accuracy in calculated organ dose and equivalent dose values relative to those obtained using the mesh phantoms in 78% in all selected organs and calculated dose quantities. Comparatively the default mesh and scaled mesh were equal or superior to the other phantoms in 21% and 28% of cases respectively. SIGNIFICANCE The proposed methodology for hybrid synthesis provides a tool for whole-body organ dose estimation for individual patients without requiring CT scans of their entire body. Such a capability would be useful for personalized assessment of late effects and risk-optimization of treatment plans.
Collapse
Affiliation(s)
- Erika Kollitz
- Department of Medical Physics, Ludwig-Maximilians-Universitat Munchen, Ludwig-Maximilians-Universität München, Department for Medical Physics (LS Parodi), Am Coulombwall 1, Garching, Bayern, 85748, GERMANY
| | - Haegin Han
- Department of Nuclear Engineering, Hanyang University, 222, Wangsimni-ro, Seongdong-gu, Seongdong-gu, Seoul, 04763, Korea (the Republic of)
| | - Chan Hyeong Kim
- Department of Nuclear Engineering, Hanyang University, 222, Wangsimni-ro, Seongdong-gu, Seongdong-gu, Seoul, 04763, Korea (the Republic of)
| | - Marco Pinto
- Ludwig-Maximilians-Universitat Munchen, Ludwig-Maximilians-Universität München, Department for Medical Physics (LS Parodi), Am Coulombwall 1, Garching, Bayern, 85748, GERMANY
| | - Marco Schwarz
- Provincia autonoma di Trento Azienda Provinciale per i Servizi Sanitari, Via Alcide Degasperi 79, Trento, Trentino-Alto Adige, 38123, ITALY
| | - Marco Riboldi
- Department of Medical Physics, Ludwig-Maximilians-Universitat Munchen, Ludwig-Maximilians-Universität München, Department for Medical Physics (LS Parodi), Am Coulombwall 1, Munchen, Bayern, 85748, GERMANY
| | - Florian Kamp
- Radiotherapy, Klinikum der Universitat Munchen, Marchioninistraße 15, Munich, 81377, GERMANY
| | - Claus Belka
- Department of Radiation Oncology, Klinikum der Universitat Munchen, Marchioninistraße 15, Munchen, Bayern, 81377, GERMANY
| | - Wayne David Newhauser
- Department of Physics & Astronomy, Louisiana State University, 202 Nicholson Hall, Baton Rouge, Louisiana, 70803, UNITED STATES
| | - Georgios Dedes
- Department of Medical Physics, Ludwig-Maximilians-Universitat Munchen, Ludwig-Maximilians-Universität München, Department for Medical Physics (LS Parodi), Am Coulombwall 1, Munchen, Bayern, 85748, GERMANY
| | - Katia Parodi
- Experimental Physics Medical Physics, Ludwig-Maximilians-Universitat Munchen, Ludwig-Maximilians-Universität München, Department for Medical Physics (LS Parodi), Am Coulombwall 1, Munchen, Bayern, 85748, GERMANY
| |
Collapse
|
17
|
Vedelago J, Geser FA, Muñoz ID, Stabilini A, Yukihara EG, Jaekel O. Assessment of secondary neutrons in particle therapy by Monte Carlo simulations. Phys Med Biol 2021; 67. [PMID: 34905742 DOI: 10.1088/1361-6560/ac431b] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2021] [Accepted: 12/14/2021] [Indexed: 11/12/2022]
Abstract
OBJECTIVE The purpose of this study is to estimate the energy and angular distribution of secondary neutrons inside a phantom in hadron therapy, which will support decisions on detector choice and experimental setup design for in-phantom secondary neutron measurements. APPROACH Dedicated Monte Carlo simulations were implemented, considering clinically relevant energies of protons, helium and carbon ions. Since scored quantities can vary from different radiation transport models, the codes FLUKA, TOPAS and MCNP were used. The geometry of an active scanning beam delivery system for heavy ion treatment was implemented, and simulations of pristine and spread-out Bragg peaks were carried out. Previous studies, focused on specific ion types or single energies, are qualitatively in agreement with the obtained results. MAIN RESULTS The secondary neutrons energy distributions present a continuous spectrum with two peaks, one centred on the thermal/epithermal region, and one on the high-energy region, with the most probable energy ranging from 19 MeV up to 240 MeV, depending on the ion type and its initial energy. The simulations show that the secondary neutron energies may exceed 400 MeV and, therefore, suitable neutron detectors for this energy range shall be needed. Additionally, the angular distribution of the low energy neutrons is quite isotropic, whereas the fast/relativistic neutrons are mainly scattered in the down-stream direction. SIGNIFICANCE It would be possible to minimize the influence of the heavy ions when measuring the neutron-generated recoil protons by selecting appropriate measurement positions within the phantom. Although there are discrepancies among the three Monte Carlo codes, the results agree qualitatively and in order of magnitude, being sufficient to support further investigations with the ultimate goal of mapping the secondary neutron doses both in- and out-of-field in hadrontherapy. The obtained secondary neutron spectra are available as supplementary material.
Collapse
Affiliation(s)
- José Vedelago
- German Cancer Research Centre, Im Neuenheimer Feld 280, Heidelberg, 69120, GERMANY
| | - Federico A Geser
- Paul Scherrer Institut, Forschungsstrasse 111, Villigen PSI, 5232, SWITZERLAND
| | - Iván D Muñoz
- German Cancer Research Centre, Im Neuenheimer Feld 280, Heidelberg, 69120, GERMANY
| | - Alberto Stabilini
- Paul Scherrer Institut, Forschungsstrasse 111, Villigen PSI, 5235, SWITZERLAND
| | - Eduardo G Yukihara
- Paul Scherrer Institut, Forschungsstrasse 111, Villigen PSI, 5232, SWITZERLAND
| | - Oliver Jaekel
- German Cancer Research Centre, Im Neuenheimer Feld 280, Heidelberg, 69120, GERMANY
| |
Collapse
|