1
|
Gordon E, Segal S, Sabou AK, Gemene KL. Quantitative determination of dextran sulfate and pentosan polysulfate and their binding with protamine using chronopotentiometry with polyion-selective electrodes. Anal Chim Acta 2021; 1149:338208. [PMID: 33551060 DOI: 10.1016/j.aca.2021.338208] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Revised: 12/21/2020] [Accepted: 01/06/2021] [Indexed: 11/18/2022]
Abstract
We report for the first time a chronopotentiometric measurement of polyanions based on localized ion depletion at the sample/membrane interface at a characteristic transition time τ, using polymer membrane polyanion-selective electrodes. Chronopotentiometric transduction of polyions based on the measurement of transition time has analytically more attractive applications compared to the controlled-current reversible pulsed chronopotentiometric transduction based on electromotive force (emf) measurement. This is because traditional polyion-selective electrodes based on emf measurement intrinsically give nonlinear (sigmoidal) calibration curves. While these can be used for indirect determination of polyions via polyanion-polycation titrations, they are not convenient for direct quantitation. However, under chronopotentiometric measurement based on the measurement of transition time, the square root of the transition time τ is linearly related to the concentration of the polyion according to the Sand equation and can be used for a direct calibration-free rapid determination. In this work, we have measured the concentrations of dextran sulfate (DS) and pentosan polysulfate (PPS) using polyanion selective electrodes under chronopotentiometric method where the transition time was measured and controlled-current pulsed chronopotentiometric transductions, where the phase boundary potential (emf) was measured. In addition, the protamine-DS and the protamine-PPS binding ratios have been determined using both transductions. The protamine-PPS binding ratio was determined to be 1.51:1 by the titration method and 1.54:1 by chronopotentiometry. The protamine-DS binding ratio was determined to be 1.37:1 by the titration method and 1.41:1 by chronopotentiometry, showing excellent agreement between the two methods. These simple measurement methods of binding ratios between polysaccharides and polypeptides may become important tools for screening safer and more reliable antidotes for the newer and safer anticoagulants such as Low Molecular Weight Heparins(LMWHs) and also to determine the dosages of antidotes needed to neutralize the anticoagulant activity.
Collapse
Affiliation(s)
- Emma Gordon
- Department of Chemistry, Northern Kentucky University, Nunn Drive, Highland Heights, KY, 41099, USA
| | - Simon Segal
- Department of Chemistry, Northern Kentucky University, Nunn Drive, Highland Heights, KY, 41099, USA
| | - Ana-Karina Sabou
- Faculty of Chemistry and Chemical Engineering, University of Babes-Bolyai, Cluj Napoca, Romania
| | - Kebede L Gemene
- Department of Chemistry, Northern Kentucky University, Nunn Drive, Highland Heights, KY, 41099, USA.
| |
Collapse
|
2
|
Logue T, Lizotte-Waniewski M, Brew K. Thermodynamic profiles of the interactions of suramin, chondroitin sulfate, and pentosan polysulfate with the inhibitory domain of TIMP-3. FEBS Lett 2019; 594:94-103. [PMID: 31359422 DOI: 10.1002/1873-3468.13556] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Revised: 07/15/2019] [Accepted: 07/21/2019] [Indexed: 01/01/2023]
Abstract
Extracellular levels of soluble TIMP-3 are low, reflecting its binding by extracellular matrix (ECM) components including sulfated glycosaminoglycans (SGAGs) and endocytosis via low density lipoprotein receptor-related protein 1. Since TIMP-3 inhibits ECM degradation, the ability of SGAGs to elevate extracellular TIMP-3 is significant for osteoarthritis treatment. Previous studies of such interactions have utilized immobilized TIMP-3 or ligands. Here, we report the thermodynamics of the interactions of the sGAG-binding N-domain of TIMP-3 with chondroitin sulfate, pentosan polysulfate, and suramin in solution using isothermal titration calorimetry. All three interactions are driven by a favorable negative enthalpy change combined with an unfavorable decrease in entropy. The heat capacity changes (ΔCp ) for all of the interactions are zero, indicating an insignificant contribution from hydrophobic interactions.
Collapse
Affiliation(s)
- Timothy Logue
- Department of Biomedical Science, Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, 33431, USA
| | - Michelle Lizotte-Waniewski
- Integrated Medical Sciences Department, Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, 33431, USA
| | - Keith Brew
- Department of Biomedical Science, Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, 33431, USA
| |
Collapse
|
3
|
Felisilda BMB, Payne AD, Arrigan DWM. Electrochemical Behavior and Detection of Sulfated Sucrose at a Liquid|Organogel Microinterface Array. Anal Chem 2018; 90:10256-10262. [DOI: 10.1021/acs.analchem.8b01710] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
4
|
Mozafari M, El Deeb S, Krull F, Wildgruber R, Weber G, Reiter CG, Wätzig H. Interaction of albumins and heparinoids investigated by affinity capillary electrophoresis and free flow electrophoresis. Electrophoresis 2017; 39:569-580. [PMID: 29131355 DOI: 10.1002/elps.201700202] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2017] [Revised: 10/20/2017] [Accepted: 11/06/2017] [Indexed: 01/04/2023]
Abstract
A fast and precise affinity capillary electrophoresis (ACE) method has been applied to investigate the interactions between two serum albumins (HSA and BSA) and heparinoids. Furthermore, different free flow electrophoresis methods were developed to separate the species which appears owing to interaction of albumins with pentosan polysulfate sodium (PPS) under different experimental conditions. For ACE experiments, the normalized mobility ratios (∆R/Rf ), which provided information about the binding strength and the overall charge of the protein-ligand complex, were used to evaluate the binding affinities. ACE experiments were performed at two different temperatures (23 and 37°C). Both BSA and HSA interact more strongly with PPS than with unfractionated and low molecular weight heparins. For PPS, the interactions can already be observed at low mg/L concentrations (3 mg/L), and saturation is already obtained at approximately 20 mg/L. Unfractionated heparin showed almost no interactions with BSA at 23°C, but weak interactions at 37°C at higher heparin concentrations. The additional signals also appeared at higher concentrations at 37°C. Nevertheless, in most cases the binding data were similar at both temperatures. Furthermore, HSA showed a characteristic splitting in two peaks especially after interacting with PPS, which is probably attributable to the formation of two species or conformational change of HSA after interacting with PPS. The free flow electrophoresis methods have confirmed and completed the ACE experiments.
Collapse
Affiliation(s)
- Mona Mozafari
- Institute of Medicinal and Pharmaceutical Chemistry, TU Braunschweig, Brunswick, Germany
| | - Sami El Deeb
- Institute of Medicinal and Pharmaceutical Chemistry, TU Braunschweig, Brunswick, Germany
| | - Friederike Krull
- Institute of Medicinal and Pharmaceutical Chemistry, TU Braunschweig, Brunswick, Germany
| | | | | | | | - Hermann Wätzig
- Institute of Medicinal and Pharmaceutical Chemistry, TU Braunschweig, Brunswick, Germany
| |
Collapse
|
5
|
Wang X, Mahoney M, Meyerhoff ME. Inkjet-Printed Paper-Based Colorimetric Polyion Sensor Using a Smartphone as a Detector. Anal Chem 2017; 89:12334-12341. [DOI: 10.1021/acs.analchem.7b03352] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Xuewei Wang
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055, United States
| | - Mollie Mahoney
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055, United States
| | - Mark E. Meyerhoff
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055, United States
| |
Collapse
|
6
|
Mozafari M, Balasupramaniam S, Preu L, El Deeb S, Reiter CG, Wätzig H. Using affinity capillary electrophoresis and computational models for binding studies of heparinoids with p-selectin and other proteins. Electrophoresis 2017; 38:1560-1571. [DOI: 10.1002/elps.201600480] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Revised: 02/28/2017] [Accepted: 03/01/2017] [Indexed: 02/01/2023]
Affiliation(s)
- Mona Mozafari
- Institute of Medicinal and Pharmaceutical Chemistry; TU Braunschweig; Braunschweig Germany
| | | | - Lutz Preu
- Institute of Medicinal and Pharmaceutical Chemistry; TU Braunschweig; Braunschweig Germany
| | - Sami El Deeb
- Institute of Medicinal and Pharmaceutical Chemistry; TU Braunschweig; Braunschweig Germany
| | | | - Hermann Wätzig
- Institute of Medicinal and Pharmaceutical Chemistry; TU Braunschweig; Braunschweig Germany
| |
Collapse
|
7
|
Felisilda BMB, Alvarez de Eulate E, Stringer DN, Fitton JH, Arrigan DWM. Electrochemical behaviour at a liquid-organogel microinterface array of fucoidan extracted from algae. Analyst 2017; 142:3194-3202. [DOI: 10.1039/c7an00761b] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The electrochemical behaviour of fucoidan, a sulfated polysaccharide, was investigated, leading to a detection strategy by adsorptive stripping voltammetry.
Collapse
Affiliation(s)
- Bren Mark B. Felisilda
- Curtin Institute of Functional Molecules and Interfaces
- Department of Chemistry
- Curtin University
- Perth
- Australia
| | - Eva Alvarez de Eulate
- Curtin Institute of Functional Molecules and Interfaces
- Department of Chemistry
- Curtin University
- Perth
- Australia
| | | | | | - Damien W. M. Arrigan
- Curtin Institute of Functional Molecules and Interfaces
- Department of Chemistry
- Curtin University
- Perth
- Australia
| |
Collapse
|
8
|
Abd-Rabboh HS, Albassami NA, Zidan NM. Single-Use Probes for the Determination of Dextran Sulfate in Food, Drug, and Industrial Samples. INT J ELECTROCHEM SC 2016; 11:1345-1354. [DOI: 10.1016/s1452-3981(23)15926-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
9
|
Quantitative determination of fucoidan using polyion-sensitive membrane electrodes. Anal Chim Acta 2015; 877:1-8. [PMID: 26002205 DOI: 10.1016/j.aca.2015.04.020] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2015] [Revised: 04/09/2015] [Accepted: 04/10/2015] [Indexed: 12/20/2022]
Abstract
The use of polyanion and polycation-sensitive membrane electrodes to detect five different preparations of fucoidan is described. Unlike linear polyanionic molecules previously measured with polymer membrane-based electrochemical sensors, fucoidans from marine brown algae are all highly branched, sulfated polysaccharides with varying charge densities and structures, depending on the species of seaweed, method of extraction used and extent of purification. When tridodecylmethylammonium (TDMA) was used as the ion-exchanger, a large, non-equilibrium EMF response was observed over a concentration range of 0.5-50 μg mL(-1) fucoidan. Fucoidan was also measured by titration with polycationic protamine, using a dinonylnaphthalene sulfonate (DNNS)-doped membrane electrode as the potentiometric endpoint detector. Potentiometric titration was used to determine the binding ratio between protamine and fucoidan at the neutralization endpoint for each fucoidan preparation. This binding ratio was then used to successfully determine the fucoidan content of commercially available nutritional supplements. Fucoidan was also measured in undiluted blood serum, demonstrating that this method may be applicable for measuring fucoidan for clinical applications.
Collapse
|
10
|
Hamidi-Asl E, Daems D, De Wael K, Van Camp G, Nagels LJ. Concentration-related response potentiometric titrations to study the interaction of small molecules with large biomolecules. Anal Chem 2014; 86:12243-9. [PMID: 25390494 DOI: 10.1021/ac503385x] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
In the present paper, the utility of a special potentiometric titration approach for recognition and calculation of biomolecule/small-molecule interactions is reported. This approach is fast, sensitive, reproducible, and inexpensive in comparison to the other methods for the determination of the association constant values (Ka) and the interaction energies (ΔG). The potentiometric titration measurement is based on the use of a classical polymeric membrane indicator electrode in a solution of the small-molecule ligand. The biomolecule is used as a titrant. The potential is measured versus a reference electrode and transformed into a concentration-related signal over the entire concentration interval, also at low concentrations, where the millivolt (y-axis) versus log canalyte (x-axis) potentiometric calibration curve is not linear. In the procedure, Ka is calculated for the interaction of cocaine with a cocaine binding aptamer and with an anticocaine antibody. To study the selectivity and cross-reactivity, other oligonucleotides and aptamers are tested, as well as other small ligand molecules such as tetrakis(4-chlorophenyl)borate, metergoline, lidocaine, and bromhexine. The calculated Ka compared favorably to the value reported in the literature using surface plasmon resonance. The potentiometric titration approach called "concentration-related response potentiometry" is used to study molecular interaction for seven macromolecular target molecules and four small-molecule ligands.
Collapse
Affiliation(s)
- Ezat Hamidi-Asl
- AXES Research Group and ‡Chromatographic Organic Trace Analysis, Department of Chemistry, University of Antwerp , Groenenborgerlaan 171, 2020 Antwerp, Belgium
| | | | | | | | | |
Collapse
|
11
|
In vitro evaluation of the antiviral activity of heparan sulfate mimetic compounds against Enterovirus 71. Virus Res 2012; 169:22-9. [DOI: 10.1016/j.virusres.2012.06.025] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2012] [Revised: 06/13/2012] [Accepted: 06/27/2012] [Indexed: 11/19/2022]
|
12
|
Benzodipyrrole derivates as new ionophores for anion-selective electrodes: Improving potentiometric selectivity towards divalent anions. Talanta 2011; 85:1876-81. [DOI: 10.1016/j.talanta.2011.07.027] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2011] [Revised: 06/27/2011] [Accepted: 07/07/2011] [Indexed: 11/21/2022]
|
13
|
Dürüst N, Meyerhoff ME, Ünal N, Naç S. Spectrophotometric determination of various polyanions with polymeric film optodes using microtiter plate reader. Anal Chim Acta 2011; 699:107-12. [DOI: 10.1016/j.aca.2011.05.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2011] [Revised: 05/01/2011] [Accepted: 05/08/2011] [Indexed: 11/30/2022]
|
14
|
Yu A, Shepherd B, Wagner M, Clapper J, Esson JM. Development of polymer-membrane based electrodes for suramin. Anal Chim Acta 2011; 686:76-80. [DOI: 10.1016/j.aca.2010.11.032] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2010] [Revised: 11/15/2010] [Accepted: 11/16/2010] [Indexed: 10/18/2022]
|
15
|
Girish Kumar K, Augustine P, John S, Radecki J, Radecka H. Fabrication of Potentiometric Sensors for the Selective Determination of Ketoconazole. ANAL LETT 2008. [DOI: 10.1080/00032710802051983] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
16
|
Dürüst N, Meyerhoff ME. Determination of DNA and its binding to protamine using potentiometric polyion sensors. J Electroanal Chem (Lausanne) 2007. [DOI: 10.1016/j.jelechem.2006.11.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
17
|
Ijeri V, Vocanson F, Martelet C, Jaffrezic-Renault N. Capacitive Sensing of Amino Acids Using Caliraxene-Coated Silicon Transducers. ELECTROANAL 2007. [DOI: 10.1002/elan.200603729] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
18
|
Spectrophotometric Determination of Metoclopramide in Pharmaceutical Preparations. JOURNAL OF ANALYTICAL CHEMISTRY 2005. [DOI: 10.1007/s10809-005-0151-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
19
|
Mostafa GAE. PVC matrix membrane sensor for potentiometric determination of metoclopramide hydrochloride in some pharmaceutical formulations. J Pharm Biomed Anal 2003; 31:515-21. [PMID: 12615239 DOI: 10.1016/s0731-7085(02)00676-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The construction and characteristic performance of metoclopramide (MCP)-polyvinyl chloride (PVC) membrane sensor are described. The sensor is based on the use of MCP-tetraiodomercurate ion pair as electroactive material in PVC matrix in presence of dioctylphthalate (DOP) as solvent mediator. MCP membrane sensor shows a stable, near Nernstian response over the concentration range 1 x 10(-2)-6 x 10(-5) M of MCP at 25 degrees C in the pH range 3-7 with cationic slope of 53.0+/-0.5. The detection limit of 4 x 10(-5) M and the response time of 30-60 s have been attained. Selectivity coefficient data for some common ions show negligible intereferences. Direct potentiometric determination of 15-3540 microg/ml MCP show an average recovery of 98.5% and a mean relative standard deviation (R.S.D.) of 1.6% at 100.0 microg/ml. The determination of MCP in Primperan tablets, injection, and syrup gave results that compare favorably with those obtained by the British pharmacopoeia method. Precipitation titrations involving MCP as titrant are monitored with the MCP sensor for some potentiometric precipitation reaction, e.g. sodium tetraphenylborate (STPB) and phosphomolybdic acid (PMA).
Collapse
Affiliation(s)
- G A E Mostafa
- Microanalytical Laboratory, Applied Organic Chemistry Department, National Research Center, Dokki, Cairo, Egypt.
| |
Collapse
|
20
|
Abd-Rabboh HSM, Nevins SA, Dürüst N, Meyerhoff ME. Electrochemical assay of protease activities based on polycation/polyanion complex as substrate and polyion sensitive membrane electrode detection. Biosens Bioelectron 2003; 18:229-36. [PMID: 12485769 DOI: 10.1016/s0956-5663(02)00181-1] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
A novel electrochemical method to detect protease activities is demonstrated. The assay is based on the use of a macromolecular polycation/polyanion substrate; specifically, a complex of the arginine-rich peptide protamine and pentosan polysulfate (PPS), a highly sulfated polysaccharide. As the protease of interest cleaves the protamine within the complex into smaller fragments, free PPS is generated and detected potentiometrically via a polyanion sensitive membrane electrode. Thus, the rate of free PPS generation is proportional to the activity of the protease in the assay solution. The effect of the substrate concentration is examined, as is the influence of the protamine/PPS stoichiometry on the assay performance. Using the optimized composition and concentration of the complex, the determination of trypsin at levels down to 5 U/ml and plasmin at levels approaching 0.002 U/ml can be achieved in a 10 min period. The prospects of further adapting this scheme to determine clot-busting plasminogen activators (e.g. streptokinase, tissue plasminogen activator, etc.) in samples as complex in whole blood are discussed.
Collapse
|