1
|
Kinyua Muthuri L, Nagy L, Nagy G. Chronopotentiometric method for assessing antioxidant activity: A reagentless measuring technique. Electrochem commun 2021. [DOI: 10.1016/j.elecom.2020.106907] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
|
2
|
Stolarczyk K, Rogalski J, Bilewicz R. NAD(P)-dependent glucose dehydrogenase: Applications for biosensors, bioelectrodes, and biofuel cells. Bioelectrochemistry 2020; 135:107574. [PMID: 32498025 DOI: 10.1016/j.bioelechem.2020.107574] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Revised: 05/21/2020] [Accepted: 05/21/2020] [Indexed: 12/13/2022]
Abstract
This review discusses the physical and chemical properties of nicotinamide redox cofactor dependent glucose dehydrogenase (NAD(P) dependent GDH) and its extensive application in biosensors and bio-fuel cells. GDHs from different organisms show diverse biochemical properties (e.g., activity and stability) and preferences towards cofactors, such as nicotinamide adenine dinucleotide (NAD+) and nicotinamide adenine dinucleotide phosphate (NADP+). The (NAD(P)+) play important roles in biological electron transfer, however, there are some difficulties related to their application in devices that originate from their chemical properties and labile binding to the GDH enzyme. This review discusses the electrode modifications aimed at immobilising NAD+ or NADP+ cofactors and GDH at electrodes. Binding of the enzyme was achieved by appropriate protein engineering techniques, including polymerisation, hydrophobisation or hydrophilisation processes. Various enzyme-modified electrodes applied in biosensors, enzymatic fuel cells, and biobatteries are compared. Importantly, GDH can operate alone or as part of an enzymatic cascade, which often improves the functional parameters of the biofuel cell or simply allows use of cheaper fuels. Overall, this review explores how NAD(P)-dependent GDH has recently demonstrated high potential for use in various systems to generate electricity from biological sources for applications in implantable biomedical devices, wireless sensors, and portable electronic devices.
Collapse
Affiliation(s)
- Krzysztof Stolarczyk
- Faculty of Chemistry, University of Warsaw, Pasteura St. 1, 02-093 Warsaw, Poland
| | - Jerzy Rogalski
- Department of Biochemistry and Biotechnology, Maria Curie-Sklodowska University, Akademicka Str. 19, 20-031 Lublin, Poland
| | - Renata Bilewicz
- Faculty of Chemistry, University of Warsaw, Pasteura St. 1, 02-093 Warsaw, Poland.
| |
Collapse
|
3
|
Kauffmann JM, Guilbault GG. Enzyme electrode biosensors: theory and applications. METHODS OF BIOCHEMICAL ANALYSIS 2006; 36:63-113. [PMID: 1552869 DOI: 10.1002/9780470110577.ch3] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- J M Kauffmann
- Université Libre de Bruxelles, Institut de Pharmacie, Belgium
| | | |
Collapse
|
4
|
Zhuang Y, Ju H. Determination of Reduced Nicotinamide Adenine Dinucleotide Based on Immobilization of Tris(2,2′‐bipyridyl) Ruthenium(II) in Multiwall Carbon Nanotubes/Nafion Composite Membrane. ANAL LETT 2005. [DOI: 10.1080/00032710500259441] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
5
|
Chapter 29 Enzyme reactors and enzyme electrodes for the liquid chromatographic determination of carbohydrates. ACTA ACUST UNITED AC 2002. [DOI: 10.1016/s0301-4770(02)80054-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
6
|
Abstract
Reports on chemical immobilization of proteins and enzymes first appeared in the 1960s. Since then, immobilized proteins and enzymes have been widely used in the processing of variety of products and increasingly used in the field of medicine. Here, we present a review of recent developments in immobilized enzyme use in medicine. Generally speaking, the use of immobilized enzyme in medicine can be divided into two major categories: biosensors and bioreactors. A brief overview of the evolution of the biosensor and bioreactor technology, of currently existing applications of immobilized enzymes, of problems that researchers encountered, and of possible future developments will be presented.
Collapse
Affiliation(s)
- J F Liang
- College of Pharmacy, The University of Michigan, 428 Church Street, Ann Arbor, Michigan 48109-1065, USA
| | | | | |
Collapse
|
7
|
Evaluation of substituted-1,10-phenanthroline complexes of osmium as mediator for glucose oxidase of Aspergillus Niger. Anal Chim Acta 2000. [DOI: 10.1016/s0003-2670(99)00799-0] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
8
|
|
9
|
Lobo MJ, Miranda AJ, Tuñón P. Amperometric biosensors based on NAD(P)-dependent dehydrogenase enzymes. ELECTROANAL 1997. [DOI: 10.1002/elan.1140090302] [Citation(s) in RCA: 176] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
10
|
Garguilo MG, Michael AC. Amperometric microsensors for monitoring choline in the extracellular fluid of brain. J Neurosci Methods 1996; 70:73-82. [PMID: 8982984 DOI: 10.1016/s0165-0270(96)00105-7] [Citation(s) in RCA: 52] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Selective amperometric enzyme microsensors for monitoring low micromolar concentrations of choline in extracellular fluid of rat brain have been developed. Preparation of the choline microsensors involved the modification of carbon fiber microcylinder electrodes (10 microns diameter, 300-400 microns long) with a cross-linked redox-active gel containing horseradish peroxidase and choline oxidase. Rejection of the noise recorded from the choline microsensors implanted in living brain tissue improved the in vivo detection capabilities of the sensors. The microsensors and a differential detection scheme were used to estimate the basal concentration of choline in striatal tissue at 6.6 +/- 2.9 microM and to measure changes in choline concentrations of 6.1 +/- 2.7 microM in vivo. The microsensors were also used to monitor choline produced following the injections of acetylcholine in vivo. Coinjections of neostigmine and acetylcholine significantly lowered the choline response recorded with the microsensors, confirming that the response following the injections of acetylcholine alone was due to the activity of endogenous acetylcholinesterase. Comparison of the maximal rate of decrease in choline concentration following the injections of 1 mM choline and 1 mM acetylcholine was used to estimate the rate of acetylcholine clearance from extracellular fluid through cholinesterase activity at approx. 2.5 microM/min.
Collapse
Affiliation(s)
- M G Garguilo
- Department of Chemistry, University of Pittsburgh, PA 15260, USA
| | | |
Collapse
|
11
|
Ye BC, Li QS, Li YR, Li XB, Yu JT. l-Glutamate biosensor using a novel l-glutamate oxidase and its application to flow injection analysis system. J Biotechnol 1995. [DOI: 10.1016/0168-1656(95)00058-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
12
|
Schlereth DD, Katz E, Schmidt HL. Surface-modified gold electrodes for electrocatalytic oxidation of NADH based on the immobilization of phenoxazine and phenothiazine derivatives on self-assembled monolayers. ELECTROANAL 1995. [DOI: 10.1002/elan.1140070105] [Citation(s) in RCA: 59] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
13
|
Schlereth DD, Katz E, Schmidt HL. Toluidine blue covalently immobilized onto gold electrode surfaces: An electrocatalytic system for nadh oxidation. ELECTROANAL 1994. [DOI: 10.1002/elan.1140060903] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
14
|
Katz E, Lötzbeyer T, Schlereth DD, Schuhmann W, Schmidt HL. Electrocatalytic oxidation of reduced nicotinamide coenzymes at gold and platinum electrode surfaces modified with a monolayer of pyrroloquinoline quinone. Effect of Ca2+ cations. J Electroanal Chem (Lausanne) 1994. [DOI: 10.1016/0022-0728(94)03328-5] [Citation(s) in RCA: 138] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
15
|
|
16
|
Electrocatalytic oxidation of reduced nicotinamide coenzymes at Methylene Green-modified electrodes and fabrication of amperometric alcohol biosensors. Anal Chim Acta 1994. [DOI: 10.1016/0003-2670(94)85016-x] [Citation(s) in RCA: 62] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
17
|
Martin AF, Nieman TA. Glucose quantitation using an immobilized glucose dehydrogenase enzyme reactor and a tris(2,2′-bipyridyl) ruthenium(II) chemiluminescent sensor. Anal Chim Acta 1993. [DOI: 10.1016/0003-2670(93)85005-5] [Citation(s) in RCA: 71] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
18
|
Michao̵wski J, Kojo̵ A, Trojanowicz M, Szostek B, Zagatto EA. Simultaneous determination of sucrose and reducing sugars using indirect flow-injection biamperometry. Anal Chim Acta 1993. [DOI: 10.1016/0003-2670(93)80051-l] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
19
|
Ortega F. Selective determination of dextrins by liquid chromatography with postcolumn enzymic reaction, using co-immobilized enzymes. Anal Chim Acta 1992. [DOI: 10.1016/0003-2670(92)80153-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
20
|
|
21
|
Kajiya Y, Matsumoto H, Yoneyama H. Glucose sensitivity of poly(pyrrole) films containing immobilized glucose dehydrogenase, nicotinamide adenine dinucleotide, and β-naphthoquinonesulphonate ions. ACTA ACUST UNITED AC 1991. [DOI: 10.1016/0022-0728(91)87077-h] [Citation(s) in RCA: 26] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
22
|
|
23
|
Gorton L, Csöregi E, Domínguez E, Emnéus J, Jönsson-Pettersson G, Marko-Varga G, Persson B. Selective detection in flow analysis based on the combination of immobilized enzymes and chemically modified electrodes. Anal Chim Acta 1991. [DOI: 10.1016/0003-2670(91)85072-z] [Citation(s) in RCA: 182] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
24
|
Tatsuma T, Watanabe T. Enzyme monolayer- and bilayer-modified electrodes with diaphorase and dehydrogenases. ACTA ACUST UNITED AC 1991. [DOI: 10.1016/0022-0728(91)85258-q] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
25
|
Sung JY, Huang HJ. Application of a polyaniline—Nafion composite electrode to the determination of alkali and alkaline earth metal ions using flow-injection analysis and ion chromatography. Anal Chim Acta 1991. [DOI: 10.1016/s0003-2670(00)80961-7] [Citation(s) in RCA: 27] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
26
|
Amperometric glucose sensor based on glucose dehydrogenase immobilized on a graphite electrode modified with an N,N′-bis(benzophenoxazinyl) derivative, of benzene-1,4-dicarboxamide. Anal Chim Acta 1991. [DOI: 10.1016/s0003-2670(00)80962-9] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
27
|
Bremle G, Persson B, Gorton L. An amperometric glucose electrode based on carbon paste, chemically modified with glucose dehydrogenase, nicotinamide adenine dinucleotide, and a phenoxazine mediator, coated with a poly(ester sulfonic acid) cation exchanger. ELECTROANAL 1991. [DOI: 10.1002/elan.1140030203] [Citation(s) in RCA: 112] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
28
|
Kajiya Y, Tsuda R, Yoneyama H. Conferment of cholesterol sensitivity on polypyrrole films by immobilization of cholesterol oxidase and ferrocenecarboxylate ions. ACTA ACUST UNITED AC 1991. [DOI: 10.1016/0022-0728(91)85466-3] [Citation(s) in RCA: 50] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
29
|
Gorton L, Bremle G, Csöregi E, Jönsson-Pettersson G, Persson B. Amperometric glucose sensors based on immobilized glucose-oxidizing enzymes and chemically modified electrodes. Anal Chim Acta 1991. [DOI: 10.1016/0003-2670(91)87006-s] [Citation(s) in RCA: 133] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
30
|
Matuszewski W, Trojanowicz M, Lewenstam A. Elimination of interferences in flow-injection amperometric determination of glucose in blood serum using immobilized glucose oxidase. ELECTROANAL 1990. [DOI: 10.1002/elan.1140020807] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
31
|
Persson B. A chemically modified graphite electrode for electrocatalytic oxidation of reduced nicotinamide adenine dinucleotide based on a phenothiazine derivative, 3-β-naphthoyl-toluidine blue O. ACTA ACUST UNITED AC 1990. [DOI: 10.1016/0022-0728(90)87160-l] [Citation(s) in RCA: 100] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
32
|
Schmid RD, Künnecke W. Flow injection analysis (FIA) based on enzymes or antibodies — applications in the life sciences. J Biotechnol 1990; 14:3-31. [PMID: 1366525 DOI: 10.1016/0168-1656(90)90014-3] [Citation(s) in RCA: 42] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Affiliation(s)
- R D Schmid
- Gesellschaft für Biotechnologische Forschung, Division of Enzyme Technology and Chemistry of Natural Substances, Braunschweig, F.R.G
| | | |
Collapse
|
33
|
Weng JL, Ho MH, Nonidez WK. Amperometric determination of formaldehyde via the hexacyanoferrate(III) -coupled dehydrogenase reaction. Anal Chim Acta 1990. [DOI: 10.1016/s0003-2670(00)83461-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
34
|
Appelqvist R, Hansen EH. Determination of glucose in fermentation processes by means of an on-line coupled flow-injection system using enzyme sensors based on chemically modified electrodes. Anal Chim Acta 1990. [DOI: 10.1016/s0003-2670(00)82083-8] [Citation(s) in RCA: 23] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
35
|
Jönsson G, Gorton L. An electrochemical sensor for hydrogen peroxide based on peroxidase adsorbed on a spectrographic graphite electrode. ELECTROANAL 1989. [DOI: 10.1002/elan.1140010515] [Citation(s) in RCA: 155] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
36
|
|
37
|
|
38
|
Wang J, Golden T. Metalloporphyrin chemically modified glassy carbon electrodes as catalytic voltammetric sensors. Anal Chim Acta 1989. [DOI: 10.1016/s0003-2670(00)80416-x] [Citation(s) in RCA: 53] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
39
|
Gunasingham H, Teo PY, Lai YH, Tan SG. Chemically modified cellulose acetate membrane for biosensor applications. BIOSENSORS-BASEL 1989. [DOI: 10.1016/0265-928x(89)80001-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
40
|
Yao T, Matsumoto Y, Wasa T. Specific detection of nicotinamide coenzymes by liquid chromatography and amperometric detection with immobilized glucose-6-phosphate dehydrogenase. Anal Chim Acta 1989. [DOI: 10.1016/s0003-2670(00)80290-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
41
|
Coughlan MP, Kierstan MP, Border PM, Turner AP. Analytical applications of immobilised proteins and cells. J Microbiol Methods 1988. [DOI: 10.1016/0167-7012(88)90039-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
42
|
Palleschi G, Rathore H, Mascini M. Amperometric probe for 3-hydroxybutyrate with immobilized 3-hydroxybutyrate dehydrogenase. Anal Chim Acta 1988. [DOI: 10.1016/s0003-2670(00)84565-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
43
|
McKenna K, Boyette SE, Brajter-Toth A. Electrochemical behavior of small biological molecules at organic donor—acceptor electrodes in aqueous media. Anal Chim Acta 1988. [DOI: 10.1016/s0003-2670(00)80832-6] [Citation(s) in RCA: 29] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
44
|
Fernández-Romero JM, de Castro L, Valcárcel M. Determination of total cholesterol in serum by flow injection analysis with immobilized enzymes. Clin Chim Acta 1987; 167:97-104. [PMID: 3665091 DOI: 10.1016/0009-8981(87)90090-8] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Several photometric and fluorimetric methods are proposed for the determination of cholesterol by use of enzymes immobilized on controlled-pore glass and the normal and stopped-flow injection modes, achieving linear ranges of the calibration curves between 26-776 mumol/l and 5-265 mumol/l with excellent regression coefficients and good coefficients of variation. The methods have been applied to the determination of this analyte in serum with excellent results.
Collapse
Affiliation(s)
- J M Fernández-Romero
- Department of Analytical Chemistry, Faculty of Sciences, University of Córdoba, Spain
| | | | | |
Collapse
|
45
|
APPELQVIST R, MARKO-VARGA G, GORTON L, JOHANSSON G. Modified Electrodes as Biosensors for Dehydrogenase Catalyzed Reactions. Ann N Y Acad Sci 1987. [DOI: 10.1111/j.1749-6632.1987.tb45769.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
46
|
Linares P, De Castro M, Valcárcel M. Sequential determination of glucose and fructose in foods by flow-injection analysis with immobilized enzymes. Anal Chim Acta 1987. [DOI: 10.1016/s0003-2670(00)85915-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
47
|
|