1
|
Dengue Virus Capsid-Protein Dynamics in Live Infected Cells Studied by Pair Correlation Analysis. Methods Mol Biol 2021. [PMID: 34709638 DOI: 10.1007/978-1-0716-1879-0_8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
It has become increasingly evident that unveiling the mechanisms of virus entry, assembly, and virion release is fundamental for identifying means for preventing viral spread and controlling viral disease. Due to virus mobility and structural and/or functional heterogeneity among viral particles, high spatiotemporal resolution single-virus/single-particle techniques are required to capture the behavior of viral particles inside infected cells.In this chapter, we present fluorescence imaging analysis methods for studying the mobility of fluorescently labeled dengue virus (DENV) proteins in live infected cells. Some of the most recent Fluorescence Fluctuation Spectroscopy (FFS) methods will be presented and, in particular, the pair Correlation Functions (pCF) approach will be discussed. The pCF method does not require individual molecule isolation, as in a particle-tracking experiment, to capture single viral protein behavior. In this regard, image acquisition is followed by the spatiotemporal cross-correlation function at increasing time delays, yielding a quantitative view of single-particle mobility in intact live infected cells.We provide a general overview and a practical guidance for the implementation of advanced FFS techniques, and the pair Correlation Functions analysis, as quantitative tools to reveal insights into previously unreported DENV mechanisms. We expect this protocol report will serve as an incentive for further applying correlation imaging studies in virology research.
Collapse
|
2
|
Petazzi RA, Aji AK, Chiantia S. Fluorescence microscopy methods for the study of protein oligomerization. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2020; 169:1-41. [DOI: 10.1016/bs.pmbts.2019.12.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
3
|
Gunther G, Jameson DM, Aguilar J, Sánchez SA. Scanning fluorescence correlation spectroscopy comes full circle. Methods 2018; 140-141:52-61. [DOI: 10.1016/j.ymeth.2018.01.023] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Revised: 01/23/2018] [Accepted: 01/30/2018] [Indexed: 11/26/2022] Open
|
4
|
Nepal M, Oyler-Yaniv A, Krichevsky O. Scanning fluorescence correlation spectroscopy as a versatile tool to measure static and dynamic properties of soft matter systems. SOFT MATTER 2015; 11:8939-8947. [PMID: 26406382 DOI: 10.1039/c5sm01582k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We present the formalism and experimental implementation of scanning fluorescence correlation spectroscopy (SFCS) for the measurements of soft matter system structure and dynamics. We relate the SFCS function Fourier transform to the system intermediate scattering function and demonstrate how SFCS can be combined with specific labelling to measure the desired statistical and kinetic features of the system. Using DNA as a model polymer, we demonstrate the application of SFCS to measure (1) the static structure factor of the system, (2) polymer end-to-end distance distribution, and (3) polymer segmental dynamics in dilute and in dense solutions. The measured DNA end-to-end distance distributions are close to Gaussian. Implementing SFCS we obtain reliable data on segmental mean-square displacement kinetics in dense solutions, where the static FCS approach fails because of dye photobleaching. For moderate concentrations in the semidilute regime (at ∼7 overlap concentrations) segmental dynamics exhibit only weak entanglements. Both of these experimental findings are consistent with theoretical predictions of the weakness of excluded interactions in semiflexible polymers.
Collapse
Affiliation(s)
- Manish Nepal
- Physics Department, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel.
| | - Alon Oyler-Yaniv
- Physics Department, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel.
| | - Oleg Krichevsky
- Physics Department, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel. and Ilse Kats Centre for Nanoscience, Ben-Gurion University, Beer-Sheva 84105, Israel
| |
Collapse
|
5
|
Song W, Moon S, Lee BC, Park CS, Kim DY, Kwon HS. Site-specific multipoint fluorescence measurement system with end-capped optical fibers. APPLIED OPTICS 2011; 50:3529-3537. [PMID: 21743563 DOI: 10.1364/ao.50.003529] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We present the development and implementation of a spatially and spectrally resolved multipoint fluorescence correlation spectroscopy (FCS) system utilizing multiple end-capped optical fibers and an inexpensive laser source. Specially prepared end-capped optical fibers placed in an image plane were used to both collect fluorescence signals from the sample and to deliver signals to the detectors. The placement of independently selected optical fibers on the image plane was done by monitoring the end-capped fiber tips at the focus using a CCD, and fluorescence from specific positions of a sample were collected by an end-capped fiber, which could accurately represent light intensities or spectral data without incurring any disturbance. A fast multipoint spectroscopy system with a time resolution of ∼1.5 ms was then implemented using a prism and an electron multiplying charge coupled device with a pixel binning for the region of interest. The accuracy of our proposed system was subsequently confirmed by experimental results, based on an FCS analysis of microspheres in distilled water. We expect that the proposed multipoint site-specific fluorescence measurement system can be used as an inexpensive fluorescence measurement tool to study many intracellular and molecular dynamics in cell biology.
Collapse
Affiliation(s)
- Woosub Song
- Department of Mechatronics, Gwangju Institute of Science and Technology, 1 Oryong-dong, Buk-gu, Gwangju 500-712, South Korea
| | | | | | | | | | | |
Collapse
|
6
|
Kurniawan NA, Rajagopalan R. Probe-independent image correlation spectroscopy. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2011; 27:2775-2782. [PMID: 21319845 DOI: 10.1021/la104478x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Conventional image correlation spectroscopy (ICS) analysis assumes point-like probe particles whose sizes are much smaller than the beam focus. This assumption yields erroneous results when the particle size is larger than a certain threshold. Here, a formalism is presented to study image correlation spectroscopy for particles of arbitrary geometries, sizes, and fluorophore distributions. We demonstrate the usefulness of this method by analyzing simulated image sequences of diffusing fluorescent point sources, disks, and randomly oriented rigid rods of various sizes. In addition, we also perform ICS analysis on confocal images of fluorescent microspheres of different diameters diffusing in a medium of known viscosity to experimentally validate the method. The new method, which we call template analysis, yields excellent agreement with theoretical predictions, thus extending the capability of ICS for studying dynamic processes in a probe-independent manner.
Collapse
Affiliation(s)
- Nicholas A Kurniawan
- NUS Graduate School for Integrative Sciences and Engineering , National University of Singapore, Singapore 117456
| | | |
Collapse
|
7
|
Abstract
Molecular diffusion and transport processes are fundamental in physical, chemical, and biological systems. Current approaches to measuring molecular transport in cells and tissues based on perturbation methods, e.g., fluorescence recovery after photobleaching, are invasive; single-point fluctuation correlation methods are local; and single-particle tracking requires the observation of isolated particles for relatively long periods of time. We discuss here the detection of molecular transport by exploiting spatiotemporal correlations measured among points at large distances (>1 μm). We illustrate the evolution of the conceptual framework that started with single-point fluorescence fluctuation analysis based on the transit of fluorescent molecules through a small volume of illumination. This idea has evolved to include the measurement of fluctuations at many locations in the sample using microscopy imaging methods. Image fluctuation analysis has become a rich and powerful technique that can be used to extract information about the spatial distribution of molecular concentration and transport in cells and tissues.
Collapse
Affiliation(s)
- Michelle A Digman
- Laboratory for Fluorescence Dynamics, Department of Biomedical Engineering, University of California, Irvine, California 92697, USA
| | | |
Collapse
|
8
|
Fluorescence Correlation and Cross-Correlation Spectroscopy Using Fluorescent Proteins for Measurements of Biomolecular Processes in Living Organisms. FLUORESCENT PROTEINS II 2011. [DOI: 10.1007/4243_2011_16] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/06/2022]
|
9
|
Gröner N, Capoulade J, Cremer C, Wachsmuth M. Measuring and imaging diffusion with multiple scan speed image correlation spectroscopy. OPTICS EXPRESS 2010; 18:21225-37. [PMID: 20941019 DOI: 10.1364/oe.18.021225] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The intracellular mobility of biomolecules is determined by transport and diffusion as well as molecular interactions and is crucial for many processes in living cells. Methods of fluorescence microscopy like confocal laser scanning microscopy (CLSM) can be used to characterize the intracellular distribution of fluorescently labeled biomolecules. Fluorescence correlation spectroscopy (FCS) is used to describe diffusion, transport and photo-physical processes quantitatively. As an alternative to FCS, spatially resolved measurements of mobilities can be implemented using a CLSM by utilizing the spatio-temporal information inscribed into the image by the scan process, referred to as raster image correlation spectroscopy (RICS). Here we present and discuss an extended approach, multiple scan speed image correlation spectroscopy (msICS), which benefits from the advantages of RICS, i.e. the use of widely available instrumentation and the extraction of spatially resolved mobility information, without the need of a priori knowledge of diffusion properties. In addition, msICS covers a broad dynamic range, generates correlation data comparable to FCS measurements, and allows to derive two-dimensional maps of diffusion coefficients. We show the applicability of msICS to fluorophores in solution and to free EGFP in living cells.
Collapse
Affiliation(s)
- Nadine Gröner
- Cell Biology & Biophysics Unit, European Molecular Biology Laboratory, Meyerhofstraße 1, 69117 Heidelberg, Germany
| | | | | | | |
Collapse
|
10
|
Shafran E, Yaniv A, Krichevsky O. Marginal nature of DNA solutions. PHYSICAL REVIEW LETTERS 2010; 104:128101. [PMID: 20366566 DOI: 10.1103/physrevlett.104.128101] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2010] [Indexed: 05/29/2023]
Abstract
We adapt a scanning fluorescence correlation spectroscopy technique to measure the structure factor of complex fluid systems and present the first measurements of the structure of semidilute solutions of long DNA polymers. The measured structure factors exhibit screening effects which, as expected for semidilute polymer solutions, grow stronger with increasing DNA concentration c. The measured concentration dependence of the screening length xi proportional to c{0.53+/-0.02} is unusual, but can be understood within the framework of a marginal solutions theory for semiflexible polymers.
Collapse
Affiliation(s)
- Eyal Shafran
- Physics Department, Ben-Gurion University, Beer-Sheva 84105, Israel
| | | | | |
Collapse
|
11
|
Vukojević V, Heidkamp M, Ming Y, Johansson B, Terenius L, Rigler R. Quantitative single-molecule imaging by confocal laser scanning microscopy. Proc Natl Acad Sci U S A 2008; 105:18176-81. [PMID: 19011092 PMCID: PMC2587633 DOI: 10.1073/pnas.0809250105] [Citation(s) in RCA: 65] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2008] [Indexed: 12/11/2022] Open
Abstract
A new approach to quantitative single-molecule imaging by confocal laser scanning microscopy (CLSM) is presented. It relies on fluorescence intensity distribution to analyze the molecular occurrence statistics captured by digital imaging and enables direct determination of the number of fluorescent molecules and their diffusion rates without resorting to temporal or spatial autocorrelation analyses. Digital images of fluorescent molecules were recorded by using fast scanning and avalanche photodiode detectors. In this way the signal-to-background ratio was significantly improved, enabling direct quantitative imaging by CLSM. The potential of the proposed approach is demonstrated by using standard solutions of fluorescent dyes, fluorescently labeled DNA molecules, quantum dots, and the Enhanced Green Fluorescent Protein in solution and in live cells. The method was verified by using fluorescence correlation spectroscopy. The relevance for biological applications, in particular, for live cell imaging, is discussed.
Collapse
Affiliation(s)
- Vladana Vukojević
- Department of Clinical Neuroscience, Karolinska Institutet, 17176 Stockholm, Sweden
| | | | - Yu Ming
- Department of Clinical Neuroscience, Karolinska Institutet, 17176 Stockholm, Sweden
| | - Björn Johansson
- Department of Clinical Neuroscience, Karolinska Institutet, 17176 Stockholm, Sweden
| | - Lars Terenius
- Department of Clinical Neuroscience, Karolinska Institutet, 17176 Stockholm, Sweden
| | - Rudolf Rigler
- Department of Medical Biochemistry and Biophysics, Karolinska Institutet, 17177 Stockholm, Sweden; and
- Laboratory of Biomedical Optics, Swiss Federal Institute of Technology, CH-1015 Lausanne, Switzerland
| |
Collapse
|
12
|
Petrov EP, Schwille P. State of the Art and Novel Trends in Fluorescence Correlation Spectroscopy. SPRINGER SERIES ON FLUORESCENCE 2008. [DOI: 10.1007/4243_2008_032] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
13
|
|
14
|
|
15
|
Advances in Image Correlation Spectroscopy: Measuring Number Densities, Aggregation States, and Dynamics of Fluorescently labeled Macromolecules in Cells. Cell Biochem Biophys 2007; 49:141-64. [DOI: 10.1007/s12013-007-9000-5] [Citation(s) in RCA: 166] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/22/2007] [Indexed: 01/27/2023]
|
16
|
Bonnet N, Delavoie F, Zahm JM. Characterizing the spatio-temporal behavior of cell populations through image auto-and cross-correlation microscopy. Biotechniques 2007; 43:107-15. [PMID: 17695260 DOI: 10.2144/000112478] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
We propose two methods for characterizing the spatio-temporal behavior of cell populations in culture. The first method, image auto-correlation microscopy (IACM), allows us to characterize the variation in the number of objects as a function of time, thus enabling the quantification of the clustering properties of cell populations to be performed. The second method, image cross-correlation microscopy (ICCM), allows us to characterize the migration properties of cell populations. The latter method does not require estimation or measurement of the trajectories of individual cells, which is very demanding when populations of >100 cells are examined. The capabilities of the two methods are demonstrated with simulated cell populations, and their usefulness is illustrated with experiments involving invasive and noninvasive tumor cell populations.
Collapse
Affiliation(s)
- Noël Bonnet
- UMRS, Inserm 514, Université de Reims Champagne-Ardenne, Reims, France.
| | | | | |
Collapse
|
17
|
Pan X, Yu H, Shi X, Korzh V, Wohland T. Characterization of flow direction in microchannels and zebrafish blood vessels by scanning fluorescence correlation spectroscopy. JOURNAL OF BIOMEDICAL OPTICS 2007; 12:014034. [PMID: 17343509 DOI: 10.1117/1.2435173] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
The investigation of flow profiles in microstructures and tissues by fluorescence correlation spectroscopy (FCS) has been a challenging topic in the past decade. Due to its inherent optical configuration, a circular focused laser beam, FCS is unable to resolve microfluidic flow directions. Earlier schemes reported the use of two laser beams or the use of nonsymmetrical laser foci to break the symmetry of the measurement system. This, however, is difficult to combine with confocal systems since it would require modifications that interfere with the imaging capabilities. We propose a method called line-scan FCS to measure different flow angles in microchannels and tissues. This method is implemented on a combined laser scanning confocal microscopy (LSCM) and FCS system that enables uncompromised imaging and spectroscopy measurements. We demonstrate that by scanning the laser beam with a defined speed and direction we can measure flow direction with the current system at an optimal resolution of at least 3 microm. The combination system is assessed by measuring flow profiles in a microchannel with and without obstruction. To extend the technique to live tissue measurements we demonstrate that line-scan FCS can determine the flow direction in zebrafish small blood vessels in a label-free approach.
Collapse
Affiliation(s)
- Xiaotao Pan
- National University of Singapore, NUS Graduate Program in Bioengineering, 28 Medical Drive, Singapore 117456, Singapore
| | | | | | | | | |
Collapse
|
18
|
Kaushalya SK, Balaji J, Garai K, Maiti S. Fluorescence correlation microscopy with real-time alignment readout. APPLIED OPTICS 2005; 44:3262-5. [PMID: 15943261 DOI: 10.1364/ao.44.003262] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
In confocal fluorescence correlation microscopy (FCM) it is important to ensure that the correlation measurement is actually performed at the chosen location of the three-dimensional image of the specimen. We present a confocal FCM design that provides an automatic real-time readout of the location in the confocal microscopic image, which is aligned with the detector of the fluorescence correlation spectrometer. The design accomplishes this without using any special positioning device. The design is based on an apertured fluorescence detector placed close to the back aperture of the objective lens and can be easily incorporated into virtually any confocal microscope. We demonstrate the method by performing FCM measurements of a dye diffusing on a cell membrane.
Collapse
|
19
|
Abstract
Fluorescence correlation spectroscopy (FCS) uses a stationary laser beam to illuminate a small sample volume and analyze the temporal behavior of the fluorescence fluctuations within the stationary observation volume. In contrast, scanning FCS (SFCS) collects the fluorescence signal from a moving observation volume by scanning the laser beam. The fluctuations now contain both temporal and spatial information about the sample. To access the spatial information we synchronize scanning and data acquisition. Synchronization allows us to evaluate correlations for every position along the scanned trajectory. We use a circular scan trajectory in this study. Because the scan radius is constant, the phase angle is sufficient to characterize the position of the beam. We introduce position-sensitive SFCS (PSFCS), where correlations are calculated as a function of lag time and phase. We present the theory of PSFCS and derive expressions for diffusion, diffusion in the presence of flow, and for immobilization. To test PSFCS we compare experimental data with theory. We determine the direction and speed of a flowing dye solution and the position of an immobilized particle. To demonstrate the feasibility of the technique for applications in living cells we present data of enhanced green fluorescent protein measured in the nucleus of COS cells.
Collapse
Affiliation(s)
- Joseph P Skinner
- School of Physics and Astronomy, University of Minnesota, Minneapolis, 55455, USA.
| | | | | |
Collapse
|
20
|
Ruan Q, Cheng MA, Levi M, Gratton E, Mantulin WW. Spatial-temporal studies of membrane dynamics: scanning fluorescence correlation spectroscopy (SFCS). Biophys J 2005; 87:1260-7. [PMID: 15298928 PMCID: PMC1304464 DOI: 10.1529/biophysj.103.036483] [Citation(s) in RCA: 150] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Giant unilamellar vesicles (GUVs) have been widely used as a model membrane system to study membrane organization, dynamics, and protein-membrane interactions. Most recent studies have relied on imaging methods, which require good contrast for image resolution. Multiple sequential image processing only detects slow components of membrane dynamics. We have developed a new fluorescence correlation spectroscopy (FCS) technique, termed scanning FCS (i.e., SFCS), which performs multiple FCS measurements simultaneously by rapidly directing the excitation laser beam in a uniform (circular) scan across the bilayer of the GUVs in a repetitive fashion. The scan rate is fast compared to the diffusion of the membrane proteins and even small molecules in the GUVs. Scanning FCS outputs a "carpet" of timed fluorescence intensity fluctuations at specific points along the scan. In this study, GUVs were assembled from rat kidney brush border membranes, which included the integral membrane proteins. Scanning FCS measurements on GUVs allowed for a straightforward detection of spatial-temporal interactions between the protein and the membrane based on the diffusion rate of the protein. To test for protein incorporation into the bilayers of the GUVs, antibodies against one specific membrane protein (NaPi II cotransporter) were labeled with ALEXA-488. Fluorescence images of the GUVs in the presence of the labeled antibody showed marginal fluorescence enhancement on the GUV membrane bilayers (poor image contrast and resolution). With the application of scanning FCS, the binding of the antibody to the GUVs was detected directly from the analysis of diffusion rates of the fluorescent antibody. The diffusion coefficient of the antibody bound to NaPi II in the GUVs was approximately 200-fold smaller than that in solution. Scanning FCS provided a simple, quantitative, yet highly sensitive method to study protein-membrane interactions.
Collapse
Affiliation(s)
- Qiaoqiao Ruan
- Department of Biophysics, University of Illinois in Urbana-Champaign, Urbana, IL, USA.
| | | | | | | | | |
Collapse
|
21
|
Balaji J, Maiti S. Quantitative measurement of the resolution and sensitivity of confocal microscopes using line-scanning fluorescence correlation spectroscopy. Microsc Res Tech 2005; 66:198-202. [PMID: 15889424 DOI: 10.1002/jemt.20162] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Spatial resolution and the sensitivity to detect a fluorophore are the two most important optical parameters that characterize a confocal microscope. However, these are rather difficult to estimate quantitatively. We show that fluorescence correlation spectroscopy (FCS) provides an easy and reliable measure of these quantities. We modify existing schemes for performing FCS on a commercial confocal microscope to carry out these measurements, and provide an analysis routine that can yield the relevant quantities. Our method does not require any modification of the confocal microscope, yet it yields a robust measure of the resolution and sensitivity of the instrument.
Collapse
Affiliation(s)
- J Balaji
- Tata Institute of Fundamental Research, Colaba, Mumbai 400005, India
| | | |
Collapse
|
22
|
Wang Z, Shah JV, Chen Z, Sun CH, Berns MW. Fluorescence correlation spectroscopy investigation of a GFP mutant-enhanced cyan fluorescent protein and its tubulin fusion in living cells with two-photon excitation. JOURNAL OF BIOMEDICAL OPTICS 2004; 9:395-403. [PMID: 15065907 DOI: 10.1117/1.1646416] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
This study investigates the feasibility of using the enhanced cyan mutant of green fluorescent protein (ECFP) as a probe for two-photon fluorescence correlation spectroscopy (FCS). Molecular dynamics and other properties of ECFP and an ECFP-tubulin fusion protein were investigated in living Potorous tridactylis (PTK2) cells. ECFP has high molecular brightness in the nucleus (eta=3.3 kcpsm) and in the cytoplasm (3.2 kcpsm) under our experimental conditions. The diffusion constants of ECFP were determined to be 20+/-7 microm(2)/s in the nucleus and 21+/-8 microm(2)/s in the cytoplasm. ECFP has stable molecular characteristics with negligible photobleaching and photodynamic effects in our measurements. At the highest concentration of monomer ECFP (425 nM) the amount of dimer ECFP was estimated to be negligible ( approximately 1.8 nM), consistent with our data analysis using a single species model. ECFP-tubulin has a diffusion constant of 6 microm(2)/s in the living cells. In addition, we demonstrate that analysis of the molecular brightness can provide a new avenue for studying the polymerization state of tubulin. We suggest that the tubulin in the vicinity of the nucleus exists primarily as a heterodimer subunit while those in the area away from the nucleus (d>5 microm) are mostly oligomers. We conclude that ECFP is a useful genetic fluorescent probe for FCS studies of various cellular processes when in fusion to other biomolecules of interest.
Collapse
Affiliation(s)
- Zifu Wang
- Beckman Laser Institute, University of California at Irvine, Irvine, California 92612, USA
| | | | | | | | | |
Collapse
|
23
|
Chirico G. Effect of a trapping force on a photon-counting histogram. APPLIED OPTICS 2002; 41:593-600. [PMID: 11993902 DOI: 10.1364/ao.41.000593] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
A theoretical study of the effect of a harmonic trapping force on the distribution of the fluorescence photon counts from Brownian particles is reported. The research of by Chen et al. [Biophys. J. 77, 553 (1999)] is extended. Simulations of the photon-counting histograms indicate that the trapping force parameters can be estimated from changes in the shapes of the histograms, at least for microspheres.
Collapse
Affiliation(s)
- Giuseppe Chirico
- Istituto Nazionale per la Fisica della Materia, Dipartamento di Fisica, Università di Milano Bicocca, Milan, Italy.
| |
Collapse
|
24
|
Chen Y, Müller JD, Ruan Q, Gratton E. Molecular brightness characterization of EGFP in vivo by fluorescence fluctuation spectroscopy. Biophys J 2002; 82:133-44. [PMID: 11751302 PMCID: PMC1302455 DOI: 10.1016/s0006-3495(02)75380-0] [Citation(s) in RCA: 169] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Abstract
We characterize the molecular properties of autofluorescence and transiently expressed EGFP in the nucleus and in the cytoplasm of HeLa cells by fluorescence correlation spectroscopy (FCS) and by photon counting histogram (PCH) analysis. PCH has been characterized and applied in vitro, but its potential for in vivo studies needs to be explored. Thus, this study mainly focuses on the characterization of PCH analysis in vivo. The strength of PCH lies in its ability to distinguish biomolecules by their molecular brightness value. Because the concept of molecular brightness is crucial for PCH analysis, we study the molecular brightness of EGFP and determine the statistical accuracy of its measurement under in vivo conditions. We started by characterizing the influence of autofluorescence on EGFP measurements. We found a molecular brightness of EGFP that is a factor of 10 higher than the brightness of the autofluorescence. Moment analysis demonstrates that the contribution of autofluorescence to fluorescence fluctuation experiments is negligible at EGFP concentrations of one protein per excitation volume. The molecular brightness of EGFP measured in the nucleus, the cytoplasm, and in vitro are identical and our study demonstrates that molecular brightness is a very stable and predictable quantity for cellular measurements. In addition to PCH, we also analyzed the autocorrelation function of EGFP. The diffusion coefficient of EGFP is a factor of 3 lower in vivo than compared to in vitro, and a simple diffusion process describes the autocorrelation function. We found that in the nucleus the fluorescence intensity is stable as a function of time, while measurements in the cytoplasm display fluorescence intensity drifts that complicate the data analysis. We introduce and discuss an analysis method that minimizes the influence of the intensity drifts on PCH analysis. This method allows us to recover the correct molecular brightness of EGFP even in the presence of drifts of the fluorescence intensity signal. We found the molecular brightness of EGFP to be a very robust parameter, and anticipate the use of PCH analysis for the study of oligomerization processes in vivo.
Collapse
Affiliation(s)
- Yan Chen
- Department of Physics, University of Illinois at Urbana Champaign, Urbana, Illinois 61801, USA.
| | | | | | | |
Collapse
|
25
|
Diaspro A, Chirico G, Federici F, Cannone F, Beretta S, Robello M. Two-photon microscopy and spectroscopy based on a compact confocal scanning head. JOURNAL OF BIOMEDICAL OPTICS 2001; 6:300-310. [PMID: 11516320 DOI: 10.1117/1.1382809] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2001] [Revised: 03/24/2001] [Accepted: 04/11/2001] [Indexed: 05/23/2023]
Abstract
We have combined a confocal laser scanning head modified for TPE (two-photon excitation) microscopy with some spectroscopic modules to study single molecules and molecular aggregates. The behavior of the TPE microscope unit has been characterized by means of point spread function measurements and of the demonstration of its micropatterning abilities. One-photon and two-photon mode can be simply accomplished by switching from a mono-mode optical fiber (one-photon) coupled to conventional laser sources to an optical module that allows IR laser beam (two-photon/TPE) delivery to the confocal laser scanning head. We have then described the characterization of the two-photon microscope for spectroscopic applications: fluorescence correlation, lifetime and fluorescence polarization anisotropy measurements. We describe the measurement of the response of the two-photon microscope to the light polarization and discuss fluorescence polarization anisotropy measurements on Rhodamine 6G as a function of the viscosity and on a globular protein, the Beta-lactoglobulin B labeled with Alexa 532 at very high dilutions. The average rotational and translational diffusion coefficients measured with fluorescence polarization anisotropy and fluorescence correlation methods are in good agreement with the protein size, therefore validating the use of the microscope for two-photon spectroscopy on biomolecules.
Collapse
Affiliation(s)
- A Diaspro
- University of Genoa, National Institute for the Physics of Matter (INFM), Department of Physics, Via Dodecaneso 33, 16146 Genova, Italy.
| | | | | | | | | | | |
Collapse
|
26
|
Chirico G, Bettati S, Mozzarelli A, Chen Y, Müller JD, Gratton E. Molecular heterogeneity of O-acetylserine sulfhydrylase by two-photon excited fluorescence fluctuation spectroscopy. Biophys J 2001; 80:1973-85. [PMID: 11259310 PMCID: PMC1301386 DOI: 10.1016/s0006-3495(01)76167-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
O-acetylserine sulfhydrylase, a homo-dimeric enzyme from Salmonella typhimurium, covalently binds one pyridoxal 5'-phosphate molecule per subunit as a fluorescent coenzyme. Different tautomers of the Schiff base between the coenzyme and lysine 41 generate structured absorption and fluorescence spectra upon one-photon excitation. We investigated the protein population heterogeneity by fluorescence correlation spectroscopy and lifetime techniques upon two-photon excitation. We sampled the fluorescence intensity from a small number of molecules (approximately 10) and analyzed the distribution of photon counts to separately determine the number and the fluorescence brightness of excited protein molecules. The changes in the average number of molecules and in the fluorescence brightness with the excitation wavelength indicate the presence of at least two fluorescent species, with two-photon excitation maxima at 660 and 800 nm. These species have been identified as the enolimine and ketoenamine tautomers of the protein-coenzyme internal aldimine. Their relative abundance is estimated to be 4:1, whereas the ratio of their two-photon cross sections is reversed with respect to the single-photon excitation case. Consistent results are obtained from the measurement of the lifetime decays, which are sensitive to the excited-state heterogeneity. At least two components were detected, with lifetimes of approximately 2.5 and 0.5 ns. The lifetimes are very close to the values measured in bulk solutions upon one-photon excitation and attributed to the ketoenamine tautomer and to a dipolar species formed upon proton dissociation in the excited state.
Collapse
Affiliation(s)
- G Chirico
- Istituto Nazionale per la Fisica della Materia, Università di Milano-Bicocca, Milano 20133, Italy.
| | | | | | | | | | | |
Collapse
|
27
|
|
28
|
|
29
|
|
30
|
Hänninen P, Soini A, Meltola N, Soini J, Soukka J, Soini E. A new microvolume technique for bioaffinity assays using two-photon excitation. Nat Biotechnol 2000; 18:548-50. [PMID: 10802624 DOI: 10.1038/75421] [Citation(s) in RCA: 68] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Bioaffinity binding assays such as the immunoassay are widely used in life science research. In an immunoassay, specific antibodies are used to bind target molecules in the sample, and quantification of the binding reaction reveals the amount of the target molecules. Here we present a method to measure bioaffinity assays using the two-photon excitation of fluorescence. In this method, microparticles are used as solid phase in binding the target molecules. The degree of binding is then quantified from individual microparticles by use of two photon excitation of fluorescence. We demonstrated the effectiveness of the method using the human alpha-fetoprotein (AFP) immunoassay, which is used to detect fetal disorders. The sensitivity and dynamic range we obtained with this assay indicate that this method can provide a cost-effective and simple way to measure various biomolecules in solution for research and clinical applications.
Collapse
Affiliation(s)
- P Hänninen
- Laboratory of Biophysics, Institute of Biomedicine, University of Turku,P.O. Box 123, 20521 Turku, Finland.
| | | | | | | | | | | |
Collapse
|
31
|
Abstract
The analysis of the intensity fluctuation of a fluorescence signal from a relatively small volume and from a few molecules contains information about the distribution of different species present in the solution and about kinetic parameters of the system. The same information is generally averaged out when the fluorescence experiment is performed in a much larger volume, typically a cuvette experiment. The fundamental reason for this difference is that the fluctuations of the fluorescence signal from a few molecules directly reflect the molecular nature of the matter. Only recently, with the advent of confocal microscopy and two-photon excitation, it has become practical to achieve small excitation volumes in which only a few fluorescent molecules are present. We introduce the concept of fluctuation spectroscopy and highlight some of the technical aspects. We discuss different analysis methods used in fluctuation spectroscopy and evaluate their use for studying protein-protein interactions.
Collapse
Affiliation(s)
- Y Chen
- Laboratory for Fluorescence Dynamics, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA.
| | | | | | | |
Collapse
|
32
|
Schwille P, Haupts U, Maiti S, Webb WW. Molecular dynamics in living cells observed by fluorescence correlation spectroscopy with one- and two-photon excitation. Biophys J 1999; 77:2251-65. [PMID: 10512844 PMCID: PMC1300505 DOI: 10.1016/s0006-3495(99)77065-7] [Citation(s) in RCA: 458] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Abstract
Multiphoton excitation (MPE) of fluorescent probes has become an attractive alternative in biological applications of laser scanning microscopy because many problems encountered in spectroscopic measurements of living tissue such as light scattering, autofluorescence, and photodamage can be reduced. The present study investigates the characteristics of two-photon excitation (2PE) in comparison with confocal one-photon excitation (1PE) for intracellular applications of fluorescence correlation spectroscopy (FCS). FCS is an attractive method of measuring molecular concentrations, mobility parameters, chemical kinetics, and fluorescence photophysics. Several FCS applications in mammalian and plant cells are outlined, to illustrate the capabilities of both 1PE and 2PE. Photophysical properties of fluorophores required for quantitative FCS in tissues are analyzed. Measurements in live cells and on cell membranes are feasible with reasonable signal-to-noise ratios, even with fluorophore concentrations as low as the single-molecule level in the sampling volume. Molecular mobilities can be measured over a wide range of characteristic time constants from approximately 10(-3) to 10(3) ms. While both excitation alternatives work well for intracellular FCS in thin preparations, 2PE can substantially improve signal quality in turbid preparations like plant cells and deep cell layers in tissue. At comparable signal levels, 2PE minimizes photobleaching in spatially restrictive cellular compartments, thereby preserving long-term signal acquisition.
Collapse
Affiliation(s)
- P Schwille
- School of Applied and Engineering Physics, Cornell University, Ithaca, New York 14853 USA.
| | | | | | | |
Collapse
|
33
|
Chen Y, Müller JD, So PT, Gratton E. The photon counting histogram in fluorescence fluctuation spectroscopy. Biophys J 1999; 77:553-67. [PMID: 10388780 PMCID: PMC1300352 DOI: 10.1016/s0006-3495(99)76912-2] [Citation(s) in RCA: 536] [Impact Index Per Article: 21.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Fluorescence correlation spectroscopy (FCS) is generally used to obtain information about the number of fluorescent particles in a small volume and the diffusion coefficient from the autocorrelation function of the fluorescence signal. Here we demonstrate that photon counting histogram (PCH) analysis constitutes a novel tool for extracting quantities from fluorescence fluctuation data, i.e., the measured photon counts per molecule and the average number of molecules within the observation volume. The photon counting histogram of fluorescence fluctuation experiments, in which few molecules are present in the excitation volume, exhibits a super-Poissonian behavior. The additional broadening of the PCH compared to a Poisson distribution is due to fluorescence intensity fluctuations. For diffusing particles these intensity fluctuations are caused by an inhomogeneous excitation profile and the fluctuations in the number of particles in the observation volume. The quantitative relationship between the detected photon counts and the fluorescence intensity reaching the detector is given by Mandel's formula. Based on this equation and considering the fluorescence intensity distribution in the two-photon excitation volume, a theoretical expression for the PCH as a function of the number of molecules in the excitation volume is derived. For a single molecular species two parameters are sufficient to characterize the histogram completely, namely the average number of molecules within the observation volume and the detected photon counts per molecule per sampling time epsilon. The PCH for multiple molecular species, on the other hand, is generated by successively convoluting the photon counting distribution of each species with the others. The influence of the excitation profile upon the photon counting statistics for two relevant point spread functions (PSFs), the three-dimensional Gaussian PSF conventionally employed in confocal detection and the square of the Gaussian-Lorentzian PSF for two photon excitation, is explicitly treated. Measured photon counting distributions obtained with a two-photon excitation source agree, within experimental error with the theoretical PCHs calculated for the square of a Gaussian-Lorentzian beam profile. We demonstrate and discuss the influence of the average number of particles within the observation volume and the detected photon counts per molecule per sampling interval upon the super-Poissonian character of the photon counting distribution.
Collapse
Affiliation(s)
- Y Chen
- Laboratory for Fluorescence Dynamics, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA.
| | | | | | | |
Collapse
|
34
|
Wiseman PW, Petersen NO. Image correlation spectroscopy. II. Optimization for ultrasensitive detection of preexisting platelet-derived growth factor-beta receptor oligomers on intact cells. Biophys J 1999; 76:963-77. [PMID: 9916027 PMCID: PMC1300045 DOI: 10.1016/s0006-3495(99)77260-7] [Citation(s) in RCA: 94] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
Previously we introduced image correlation spectroscopy (ICS) as an imaging analog of fluorescence correlation spectroscopy (FCS). Implementation of ICS with image collection via a standard fluorescence confocal microscope and computer-based autocorrelation analysis was shown to facilitate measurements of absolute number densities and determination of changes in aggregation state for fluorescently labeled macromolecules. In the present work we illustrate how to use ICS to quantify the aggregation state of immunolabeled plasma membrane receptors in an intact cellular milieu, taking into account background fluorescence. We introduce methods that enable us to completely remove white noise contributions from autocorrelation measurements for individual images and illustrate how to perform background corrections for autofluorescence and nonspecific fluorescence on cell population means obtained via ICS. The utilization of photon counting confocal imaging with ICS analysis in combination with the background correction techniques outlined enabled us to achieve very low detection limits with standard immunolabeling methods on normal, nontransformed human fibroblasts (AG1523) expressing relatively low numbers of platelet-derived growth factor-beta (PDGF-beta) receptors. Specifically, we determined that the PDGF-beta receptors were preaggregated as tetramers on average with a mean surface density of 2.3 clusters micrometer(-2) after immunolabeling at 4 degreesC. These measurements, which show preclustering of PDGF-beta receptors on the surface of normal human fibroblasts, contradict a fundamental assumption of the ligand-induced dimerization model for signal transduction and provide support for an alternative model that posits signal transduction from within preexisting receptor aggregates.
Collapse
Affiliation(s)
- P W Wiseman
- Department of Chemistry, The University of Western Ontario, London, Ontario N6A 5B7, Canada
| | | |
Collapse
|
35
|
|
36
|
Abstract
Two dimensional motion of membrane receptors provides a mechanism for interaction among receptors in the plane of the membrane. In some cases the lateral diffusion leads to formation of clusters which may also be mobile. We have used image cross-correlation (ICCS) spectroscopy technique to measure the translational motion of transferrin receptors in the membrane of 3T3 fibroblasts and HEp2 carcinoma cells. The technique is based on the measurement and analysis of fluctuations in the intensity observed in fluorescence confocal microscope images measured as a function of time. The fluorescence fluctuations arise from stochastic concentration fluctuations about the equilibrium concentration caused by movement of receptors. The amplitude of the fluctuations depend on the number of fluorescent molecules in the observation volume and the dynamics provide the rate of movement. The diffusion observed by this analysis is orders of magnitude slower than that measured by conventional photobleaching techniques. The slower motion corresponds to the diffusion of receptor clusters which provide the more dominant fluctuations.
Collapse
Affiliation(s)
- M Srivastava
- Department of Chemistry, University of Western Ontario, London, Canada
| | | |
Collapse
|
37
|
Schlingloff G, Kiel HJ, Schober A. Microlenses as Amplification for CCD-Based Detection Devices for Screening Applications in Biology, Biochemistry, and Chemistry. APPLIED OPTICS 1998; 37:1930-1934. [PMID: 18273112 DOI: 10.1364/ao.37.001930] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
We describe the use of microlenses as amplification for CCD-based detection devices. The possible amplification of a signal in areaction chamber of a nanoplate is estimated with a first-order approximation. This value was proved with a commercially available microlens and with a specially constructed microlens array made of glass hemispheres. Possible applications of this approach to amplification are given.
Collapse
|
38
|
Maiti S, Haupts U, Webb WW. Fluorescence correlation spectroscopy: diagnostics for sparse molecules. Proc Natl Acad Sci U S A 1997; 94:11753-7. [PMID: 9342306 PMCID: PMC33774 DOI: 10.1073/pnas.94.22.11753] [Citation(s) in RCA: 227] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
The robust glow of molecular fluorescence renders even sparse molecules detectable and susceptible to analysis for concentration, mobility, chemistry, and photophysics. Correlation spectroscopy, a statistical-physics-based tool, gleans quantitative information from the spontaneously fluctuating fluorescence signals obtained from small molecular ensembles. This analytical power is available for studying molecules present at minuscule concentrations in liquid solutions (less than one nanomolar), or even on the surfaces of living cells at less than one macromolecule per square micrometer. Indeed, routines are becoming common to detect, locate, and examine individual molecules under favorable conditions.
Collapse
Affiliation(s)
- S Maiti
- Applied Physics, Cornell University, Ithaca, NY 14853, USA
| | | | | |
Collapse
|
39
|
Schwille P, Bieschke J, Oehlenschläger F. Kinetic investigations by fluorescence correlation spectroscopy: the analytical and diagnostic potential of diffusion studies. Biophys Chem 1997; 66:211-28. [PMID: 9362560 DOI: 10.1016/s0301-4622(97)00061-6] [Citation(s) in RCA: 120] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
This review demonstrates the large analytical and diagnostic potential of fluorescence correlation spectroscopy applied to freely diffusing biomolecules in solution. All applications discussed here in detail are based on changes in the diffusion characteristics of fluorescenctly labeled complementary strands of nucleic acids when they associate. However, the principle of the measurement can be extended to many different reactions with characteristic association times between several minutes up to several hours. If the reaction significantly affects the diffusion constants of at least one partner, single-color auto-correlation analysis is sufficient to extract kinetic parameters. If the observed binding process has only a moderate effect on diffusion coefficients, the detection selectivity and sensitivity can be improved by dual-color cross-correlation analysis. Finally, we show that diffusional analysis on the single-molecule level even opens up diagnostic applications, such as the detection of minute amounts of infectious agents like HIV-1 viruses in blood.
Collapse
Affiliation(s)
- P Schwille
- Max-Planck-Institut für Biophysikalische Chemie, Abteilung Biochemische Kinetik, Göttingen, Germany
| | | | | |
Collapse
|
40
|
|
41
|
Saxton MJ, Jacobson K. Single-particle tracking: applications to membrane dynamics. ANNUAL REVIEW OF BIOPHYSICS AND BIOMOLECULAR STRUCTURE 1997; 26:373-99. [PMID: 9241424 DOI: 10.1146/annurev.biophys.26.1.373] [Citation(s) in RCA: 1225] [Impact Index Per Article: 45.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Measurements of trajectories of individual proteins or lipids in the plasma membrane of cells show a variety of types of motion. Brownian motion is observed, but many of the particles undergo non-Brownian motion, including directed motion, confined motion, and anomalous diffusion. The variety of motion leads to significant effects on the kinetics of reactions among membrane-bound species and requires a revision of existing views of membrane structure and dynamics.
Collapse
Affiliation(s)
- M J Saxton
- Institute of Theoretical Dynamics, University of California, Davis 95616, USA.
| | | |
Collapse
|
42
|
Berland KM, So PT, Chen Y, Mantulin WW, Gratton E. Scanning two-photon fluctuation correlation spectroscopy: particle counting measurements for detection of molecular aggregation. Biophys J 1996; 71:410-20. [PMID: 8804624 PMCID: PMC1233492 DOI: 10.1016/s0006-3495(96)79242-1] [Citation(s) in RCA: 125] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
Scanning fluctuation correlation spectroscopy (FCS) is an experimental technique capable of measuring particle number concentrations by monitoring spontaneous equilibrium fluctuations in the local concentration of a fluorescent species in a small (femtoliter) subvolume of a sample. The method can be used to detect molecular aggregation for dilute, submicromolar samples by directly "counting particles". We introduce the application of two-photon excitation to scanning FCS and discuss its important advantages for this technique. We demonstrate the capability of measuring particle number concentrations in solution, first with dilute samples of monodisperse 7-nm and 15-nm radius latex spheres, and then with B phycoerythrin. The detection of multiple species in a single sample is shown, using mixtures containing both sphere sizes. The method is then applied to study protein aggregation in solution. We monitor the concentration-dependent association/ dissociation equilibrium for glycogen phosphorylase A and malate dehydrogenase. The measured dissociation constants, 430 nM and 144 nM respectively, are in good agreement with previously published values. In addition, oligomer dissociation induced by pH titration from pH 8 to pH 5.0 is detectable for the enyme phosphofructokinase. The possibility of measuring dissociation kinetics by scanning two-photon FCS is also demonstrated using phosphofructokinase.
Collapse
Affiliation(s)
- K M Berland
- Department of Physics, University of Illinois at Urbana-Champaign 61801, USA.
| | | | | | | | | |
Collapse
|
43
|
Huang Z, Thompson NL. Imaging fluorescence correlation spectroscopy: nonuniform IgE distributions on planar membranes. Biophys J 1996; 70:2001-7. [PMID: 8785359 PMCID: PMC1225169 DOI: 10.1016/s0006-3495(96)79766-7] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
Fluorescence correlation spectroscopy is useful for detecting and characterizing molecular clusters that are smaller than or approximately equal to optical resolution in size. Here, we report the development of an approach in which the pixel-to-pixel fluorescence fluctuations from a single fluorescence image are spatially autocorrelated. In these measurements, tetramethylrhodamine-labeled, anti-trinitrophenyl IgE antibodies were specifically bound to substrate-supported planar membranes composed of trinitrophenyl-aminocaproyldipalmitoylphosphatidylethanolamine and dipalmitoylphosphatidylcholine. The antibody-coated membranes were illuminated with the evanescent field from a totally internally reflected laser beam, and the fluorescence arising from the IgE-coated membranes was recorded with a cooled CCD camera. The image was corrected for the elliptical Gaussian shape of the evanescent illumination after background subtraction. The spatial autocorrelation functions of the resulting images generated two useful parameters: the extrapolated initial values, which were related to the average cluster intensity and density; and the correlation distances, which were related to the average cluster size. These parameters varied with the IgE density, and unlabeled polyclonal anti-IgE enhanced the nonuniform IgE distributions. The autocorrelation functions calculated from images of planar membranes containing fluorescently labeled lipids rather than bound, labeled IgE demonstrated that the spatial nonuniformities were prominent only in the presence of IgE. Fluorescent beads were used to demonstrate the principles and the methods.
Collapse
Affiliation(s)
- Z Huang
- Department of Chemistry, University of North Carolina, Chapel Hill 27599-3290, USA
| | | |
Collapse
|
44
|
Image cross-correlation spectroscopy: A new experimental biophysical approach to measurement of slow diffusion of fluorescent molecules. ACTA ACUST UNITED AC 1996. [DOI: 10.1007/bf00123523] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
45
|
Berland KM, So PT, Gratton E. Two-photon fluorescence correlation spectroscopy: method and application to the intracellular environment. Biophys J 1995; 68:694-701. [PMID: 7696520 PMCID: PMC1281733 DOI: 10.1016/s0006-3495(95)80230-4] [Citation(s) in RCA: 400] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
We report on the application of two photon molecular excitation to fluorescence correlation spectroscopy. We demonstrate the first fluorescence correlation spectroscopy measurements of translational mobility in the cytoplasm of living cells. Two-photon excitation inherently excites small sample volumes in three dimensions, providing depth discrimination similar to confocal microscopy, without emission pinholes. We demonstrated accurate measurements of the diffusion constant, D, for particles of several different known sizes, in bulk solutions of different viscosity. We then showed measurements of translational diffusion for 7- and 15-nm radius latex beads in the cytoplasm of mouse fibroblast cells. We measured time-dependent diffusion coefficients. When first injected in the cells, the spheres moved from two to five times slower than in water, with average rates of 18 x 10(-8) cm2/s for the 7 nm and 5 x 10(-8) cm2/s for the 15 nm radius spheres. After a few hours, spheres stick to the cells, and the motion slows down 10 to 100 times.
Collapse
Affiliation(s)
- K M Berland
- Department of Physics, University of Illinois at Urbana-Champaign 61801
| | | | | |
Collapse
|