1
|
Eşmekaya MA, Gürsoy G, Coşkun A. The estimation of pore size distribution of electroporated MCF-7 cell membrane. Electromagn Biol Med 2024; 43:176-186. [PMID: 38900674 DOI: 10.1080/15368378.2024.2366272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Accepted: 06/05/2024] [Indexed: 06/22/2024]
Abstract
The size of the pores created by external electrical pulses is important for molecule delivery into the cell. The size of pores and their distribution on the cell membrane determine the efficiency of molecule transport into the cell. There are very few studies visualizing the presence of electropores. In this study, we aimed to investigate the size distribution of electropores that were created by high intensity and short duration electrical pulses on MCF-7 cell membrane. Scanning Electron Microscopy (SEM) was used to visualize and characterize the membrane pores created by the external electric field. Structural changes on the surface of the electroporated cell membrane was observed by Atomic Force Microscopy (AFM). The size distribution of pore sizes was obtained by measuring the radius of 500 electropores. SEM imaging showed non-uniform patterning. The average radius of the electropores was 12 nm, 51.60% of pores were distributed within the range of 5 to 10 nm, and 81% of pores had radius below 15 nm. These results showed that microsecond (µs) high intensity electrical pulses cause the creation of heterogeneous nanopores on the cell membrane.
Collapse
Affiliation(s)
- Meriç Arda Eşmekaya
- Department of Biophysics, Basic Medical Sciences, Faculty of Medicine, Gazi University, Ankara, Turkey
| | - Güney Gürsoy
- Department of Biophysics, Basic Medical Sciences, Faculty of Medicine, Kırşehir Ahi Evran University, Kırsehır, Turkey
| | - Alaaddin Coşkun
- Department of Biophysics, Basic Medical Sciences, Faculty of Medicine, Kırıkkale University, Kırıkkale, Turkey
| |
Collapse
|
2
|
Urbanskas E, Jakštys B, Venckus J, Malakauskaitė P, Šatkauskienė I, Morkvėnaitė-Vilkončienė I, Šatkauskas S. Interplay between Electric Field Strength and Number of Short-Duration Pulses for Efficient Gene Electrotransfer. Pharmaceuticals (Basel) 2024; 17:825. [PMID: 39065676 PMCID: PMC11279932 DOI: 10.3390/ph17070825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2024] [Revised: 06/08/2024] [Accepted: 06/18/2024] [Indexed: 07/28/2024] Open
Abstract
Electroporation is a method that shows great promise as a non-viral approach for delivering genes by using high-voltage electric pulses to introduce DNA into cells to induce transient gene expression. This research aimed to evaluate the interplay between electric pulse intensity and 100 µs-duration pulse numbers as an outcome of gene electrotransfer efficacy and cell viability. Our results indicated a close relationship between pulse number and electric field strength regarding gene electrotransfer efficacy; higher electric pulse intensity resulted in fewer pulses needed to achieve the same gene electrotransfer efficacy. Subsequently, an increase in pulse number had a more negative impact on overall gene electrotransfer by significantly reducing cell viability. Based on our data, the best pulse parameters to transfect CHO cells with the pMax-GFP plasmid were using 5 HV square wave pulses of 1000 V/cm and 2 HV of 1600 V/cm, correspondingly resulting in 55 and 71% of transfected cells and maintaining 79 and 54% proliferating cells. This shows ESOPE-like 100 µs-duration pulse protocols can be used simultaneously to deliver cytotoxic drugs as well as immune response regulating genetically encoded cytokines.
Collapse
Affiliation(s)
- Ernestas Urbanskas
- Research Institute of Natural and Technological Sciences, Vytautas Magnus University, 44404 Kaunas, Lithuania; (E.U.); (B.J.); (J.V.); (I.Š.)
| | - Baltramiejus Jakštys
- Research Institute of Natural and Technological Sciences, Vytautas Magnus University, 44404 Kaunas, Lithuania; (E.U.); (B.J.); (J.V.); (I.Š.)
- Faculty of Electronics, Vilnius Gediminas Technical University, 10105 Vilnius, Lithuania;
| | - Justinas Venckus
- Research Institute of Natural and Technological Sciences, Vytautas Magnus University, 44404 Kaunas, Lithuania; (E.U.); (B.J.); (J.V.); (I.Š.)
| | - Paulina Malakauskaitė
- Faculty of Electronics, Vilnius Gediminas Technical University, 10105 Vilnius, Lithuania;
- Department of Immunology and Bioelectrochemistry, State Research Institute Centre for Innovative Medicine, 08406 Vilnius, Lithuania
| | - Ingrida Šatkauskienė
- Research Institute of Natural and Technological Sciences, Vytautas Magnus University, 44404 Kaunas, Lithuania; (E.U.); (B.J.); (J.V.); (I.Š.)
| | - Inga Morkvėnaitė-Vilkončienė
- Department of Nanotechnology, State Research Institute Centre for Physical Sciences and Technology, 02300 Vilnius, Lithuania;
| | - Saulius Šatkauskas
- Research Institute of Natural and Technological Sciences, Vytautas Magnus University, 44404 Kaunas, Lithuania; (E.U.); (B.J.); (J.V.); (I.Š.)
| |
Collapse
|
3
|
Liu F, Su R, Jiang X, Wang S, Mu W, Chang L. Advanced micro/nano-electroporation for gene therapy: recent advances and future outlook. NANOSCALE 2024; 16:10500-10521. [PMID: 38757536 DOI: 10.1039/d4nr01408a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2024]
Abstract
Gene therapy is a promising disease treatment approach by editing target genes, and thus plays a fundamental role in precision medicine. To ensure gene therapy efficacy, the effective delivery of therapeutic genes into specific cells is a key challenge. Electroporation utilizes short electric pulses to physically break the cell membrane barrier, allowing gene transfer into the cells. It dodges the off-target risks associated with viral vectors, and also stands out from other physical-based gene delivery methods with its high-throughput and cargo-accelerating features. In recent years, with the help of advanced micro/nanotechnology, micro/nanostructure-integrated electroporation (micro/nano-electroporation) techniques and devices have significantly improved cell viability, transfection efficiency and dose controllability of the electroporation strategy, enhancing its application practicality especially in vivo. This technical advancement makes micro/nano-electroporation an effective and versatile tool for gene therapy. In this review, we first introduce the evolution of electroporation technique with a brief explanation of the perforation mechanism, and then provide an overview of the recent advancements and prospects of micro/nano-electroporation technology in the field of gene therapy. To comprehensively showcase the latest developments of micro/nano-electroporation technology in gene therapy, we focus on discussing micro/nano-electroporation devices and current applications at both in vitro and in vivo levels. Additionally, we outline the ongoing clinical studies of gene electrotransfer (GET), revealing the tremendous potential of electroporation-based gene delivery in disease treatment and healthcare. Lastly, the challenges and future directions in this field are discussed.
Collapse
Affiliation(s)
- Feng Liu
- Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China
| | - Rongtai Su
- Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China
| | - Xinran Jiang
- Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China
| | - Siqi Wang
- Department of General Surgery and Obesity and Metabolic Disease Center, China-Japan Friendship Hospital, Beijing, 100029, China
| | - Wei Mu
- Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China
- School of Engineering Medicine, Beihang University, Beijing, 100191, China
- Key Laboratory of Big Data-Based Precision Medicine (Beihang University), Ministry of Industry and Information Technology of the People's Republic of China, Beijing, 100191, China
| | - Lingqian Chang
- Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China
| |
Collapse
|
4
|
Pavlin M, Škorja Milić N, Kandušer M, Pirkmajer S. Importance of the electrophoresis and pulse energy for siRNA-mediated gene silencing by electroporation in differentiated primary human myotubes. Biomed Eng Online 2024; 23:47. [PMID: 38750477 PMCID: PMC11097476 DOI: 10.1186/s12938-024-01239-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 04/23/2024] [Indexed: 05/18/2024] Open
Abstract
BACKGROUND Electrotransfection is based on application of high-voltage pulses that transiently increase membrane permeability, which enables delivery of DNA and RNA in vitro and in vivo. Its advantage in applications such as gene therapy and vaccination is that it does not use viral vectors. Skeletal muscles are among the most commonly used target tissues. While siRNA delivery into undifferentiated myoblasts is very efficient, electrotransfection of siRNA into differentiated myotubes presents a challenge. Our aim was to develop efficient protocol for electroporation-based siRNA delivery in cultured primary human myotubes and to identify crucial mechanisms and parameters that would enable faster optimization of electrotransfection in various cell lines. RESULTS We established optimal electroporation parameters for efficient siRNA delivery in cultured myotubes and achieved efficient knock-down of HIF-1α while preserving cells viability. The results show that electropermeabilization is a crucial step for siRNA electrotransfection in myotubes. Decrease in viability was observed for higher electric energy of the pulses, conversely lower pulse energy enabled higher electrotransfection silencing yield. Experimental data together with the theoretical analysis demonstrate that siRNA electrotransfer is a complex process where electropermeabilization, electrophoresis, siRNA translocation, and viability are all functions of pulsing parameters. However, despite this complexity, we demonstrated that pulse parameters for efficient delivery of small molecule such as PI, can be used as a starting point for optimization of electroporation parameters for siRNA delivery into cells in vitro if viability is preserved. CONCLUSIONS The optimized experimental protocol provides the basis for application of electrotransfer for silencing of various target genes in cultured human myotubes and more broadly for electrotransfection of various primary cell and cell lines. Together with the theoretical analysis our data offer new insights into mechanisms that underlie electroporation-based delivery of short RNA molecules, which can aid to faster optimisation of the pulse parameters in vitro and in vivo.
Collapse
Affiliation(s)
- Mojca Pavlin
- Institute of Biophysics, Faculty of Medicine, University of Ljubljana, Vrazov Trg 2, 1000, Ljubljana, Slovenia.
- Group for Nano and Biotechnological Applications, Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia.
| | - Nives Škorja Milić
- Institute of Pathophysiology, Faculty of Medicine, University of Ljubljana, Zaloška 4, 1000, Ljubljana, Slovenia
- Institute of Anatomy, Faculty of Medicine, University of Ljubljana, Korytkova 2, Ljubljana, Slovenia
| | - Maša Kandušer
- Group for Nano and Biotechnological Applications, Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia
- Pharmacy Institute, Faculty of Pharmacy, University of Ljubljana, Ljubljana, Slovenia
| | - Sergej Pirkmajer
- Institute of Pathophysiology, Faculty of Medicine, University of Ljubljana, Zaloška 4, 1000, Ljubljana, Slovenia.
| |
Collapse
|
5
|
Berry-Kilgour C, Wise L, King J, Oey I. Application of pulsed electric field technology to skin engineering. Front Bioeng Biotechnol 2024; 12:1386725. [PMID: 38689761 PMCID: PMC11058833 DOI: 10.3389/fbioe.2024.1386725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Accepted: 04/01/2024] [Indexed: 05/02/2024] Open
Abstract
Tissue engineering encompasses a range of techniques that direct the growth of cells into a living tissue construct for regenerative medicine applications, disease models, drug discovery, and safety testing. These techniques have been implemented to alleviate the clinical burdens of impaired healing of skin, bone, and other tissues. Construct development requires the integration of tissue-specific cells and/or an extracellular matrix-mimicking biomaterial for structural support. Production of such constructs is generally expensive and environmentally costly, thus eco-sustainable approaches should be explored. Pulsed electric field (PEF) technology is a nonthermal physical processing method commonly used in food production and biomedical applications. In this review, the key principles of PEF and the application of PEF technology for skin engineering will be discussed, with an emphasis on how PEF can be applied to skin cells to modify their behaviour, and to biomaterials to assist in their isolation or sterilisation, or to modify their physical properties. The findings indicate that the success of PEF in tissue engineering will be reliant on systematic evaluation of key parameters, such as electric field strength, and their impact on different skin cell and biomaterial types. Linking tangible input parameters to biological responses critical to healing will assist with the development of PEF as a sustainable tool for skin repair and other tissue engineering applications.
Collapse
Affiliation(s)
- C. Berry-Kilgour
- Department of Pharmacology and Toxicology, School of Biomedical Sciences, University of Otago, Dunedin, New Zealand
| | - L. Wise
- Department of Pharmacology and Toxicology, School of Biomedical Sciences, University of Otago, Dunedin, New Zealand
| | - J. King
- Department of Food Sciences, University of Otago, Dunedin, New Zealand
- Riddet Institute, Palmerston North, New Zealand
| | - I. Oey
- Department of Food Sciences, University of Otago, Dunedin, New Zealand
- Riddet Institute, Palmerston North, New Zealand
| |
Collapse
|
6
|
Tabaja C, Younis A, Hussein AA, Taigen TL, Nakagawa H, Saliba WI, Sroubek J, Santangeli P, Wazni OM. Catheter-Based Electroporation: A Novel Technique for Catheter Ablation of Cardiac Arrhythmias. JACC Clin Electrophysiol 2023; 9:2008-2023. [PMID: 37354168 DOI: 10.1016/j.jacep.2023.03.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 03/17/2023] [Accepted: 03/23/2023] [Indexed: 06/26/2023]
Abstract
Catheter ablation of arrhythmias is now standard of care in invasive electrophysiology. Current ablation strategies are based on the use of thermal energy. With continuous efforts to optimize thermal energy delivery, effectiveness has greatly improved; however, safety concerns persist. This review focuses on a novel ablation technology, irreversible electroporation (IRE), also known as pulsed-field ablation which may be a safer alternative for arrhythmia management. Pulsed-field ablation is thought to be a nonthermal ablation that applies short-duration high-voltage electrical fields to ablate myocardial tissue with high selectivity and durability while sparing important neighboring structures such as the esophagus and phrenic nerves. There are multiple ongoing studies investigating the potential superior outcomes of IRE compared to radiofrequency ablation in treating patients with atrial and ventricular arrhythmias. In this review, we describe the current evidence of preclinical and clinical trials that have shown promising results of catheter-based IRE.
Collapse
Affiliation(s)
- Chadi Tabaja
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA
| | - Arwa Younis
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA
| | - Ayman A Hussein
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA
| | - Tyler L Taigen
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA
| | - Hiroshi Nakagawa
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA
| | - Walid I Saliba
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA
| | - Jakub Sroubek
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA
| | - Pasquale Santangeli
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA
| | - Oussama M Wazni
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA.
| |
Collapse
|
7
|
Razakamanantsoa L, Rajagopalan NR, Kimura Y, Sabbah M, Thomassin-Naggara I, Cornelis FH, Srimathveeravalli G. Acute ATP loss during irreversible electroporation mediates caspase independent cell death. Bioelectrochemistry 2023; 150:108355. [PMID: 36549173 PMCID: PMC9892257 DOI: 10.1016/j.bioelechem.2022.108355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 12/13/2022] [Accepted: 12/15/2022] [Indexed: 12/23/2022]
Abstract
Irreversible electroporation (IRE) has been reported to variably cause apoptosis, necrosis, oncosis or pyroptosis. Intracellular ATP is a key substrate for apoptosis which is rapidly depleted during IRE, we sought to understand whether intracellular ATP levels is a determinant of the mode of cell death following IRE. A mouse bladder cancer cell line (MB49) was treated with electric fields while increasing the number of pulses at a fixed electric field strength, and pulse width. Cell proliferation and viability and ATP levels were measured at different timepoints post-treatment. Cell death was quantified with Annexin-V/Propidium Iodide staining. Caspase activity was measure with a fluorometric kit and western blotting. A pan-caspase (Z-VAD-FMK) inhibitor was used to assess the impact of signal inhibition. We found cell death following IRE was insensitive to caspase inhibition and was correlated with ATP loss. These findings were confirmed by cell death assays and measurement of changes in caspase expression on immunoblotting. This effect could not be rescued by ATP supplementation. Rapid and acute ATP loss during IRE interferes with caspase signaling, promoting necrosis. Cell necrosis from IRE is expected to be immunostimulatory and may be effective in cancer cells that carry mutated or defective apoptosis genes.
Collapse
Affiliation(s)
- Leo Razakamanantsoa
- Sorbonne University, Department of Radiology, Tenon Hospital, 4 rue de la Chine, 75020 Paris, France; Department of Mechanical and Industrial Engineering, University of Massachusetts Amherst, Amherst, MA 01003, United States.
| | - Neeraj R Rajagopalan
- Department of Mechanical and Industrial Engineering, University of Massachusetts Amherst, Amherst, MA 01003, United States.
| | - Yasushi Kimura
- Department of Mechanical and Industrial Engineering, University of Massachusetts Amherst, Amherst, MA 01003, United States
| | - Michele Sabbah
- Saint-Antoine Research Center (CRSA), INSERM, CNRS, Sorbonne Université, F-75012 Paris, France.
| | - Isabelle Thomassin-Naggara
- Sorbonne University, Department of Radiology, Tenon Hospital, 4 rue de la Chine, 75020 Paris, France; Saint-Antoine Research Center (CRSA), INSERM, CNRS, Sorbonne Université, F-75012 Paris, France.
| | - François H Cornelis
- Interventional Radiology Service, Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, NY, USA.
| | - Govindarajan Srimathveeravalli
- Department of Mechanical and Industrial Engineering, University of Massachusetts Amherst, Amherst, MA 01003, United States; Institute for Applied Life Sciences, University of Massachusetts, Amherst, MA, USA.
| |
Collapse
|
8
|
Mahdi AK, Medrano JF, Ross PJ. Single-Step Genome Editing of Small Ruminant Embryos by Electroporation. Int J Mol Sci 2022; 23:ijms231810218. [PMID: 36142132 PMCID: PMC9499182 DOI: 10.3390/ijms231810218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 08/18/2022] [Accepted: 08/19/2022] [Indexed: 11/17/2022] Open
Abstract
We investigated the possibility of single-step genome editing in small ruminants by CRISPR-Cas9 zygote electroporation. We targeted SOCS2 and PDX1 in sheep embryos and OTX2 in goat embryos, utilizing a dual sgRNA approach. Gene editing efficiency was compared between microinjection and three different electroporation settings performed at four different times of embryo development. Electroporation of sheep zygotes 6 h after fertilization with settings that included short high-voltage (poring) and long low-voltage (transfer) pulses was efficient at producing SOCS2 knock-out blastocysts. The mutation rate after CRISPR/Cas9 electroporation was 95.6% ± 8%, including 95.4% ± 9% biallelic mutations; which compared favorably to 82.3% ± 8% and 25% ± 10%, respectively, when using microinjection. We also successfully disrupted the PDX1 gene in sheep and the OTX2 gene in goat embryos. The biallelic mutation rate was 81 ± 5% for PDX1 and 85% ± 6% for OTX2. In conclusion, using single-step CRISPR-Cas9 zygote electroporation, we successfully introduced biallelic deletions in the genome of small ruminant embryos.
Collapse
|
9
|
Wang F, Lin S, Yu Z, Wang Y, Zhang D, Cao C, Wang Z, Cui D, Chen D. Recent advances in microfluidic-based electroporation techniques for cell membranes. LAB ON A CHIP 2022; 22:2624-2646. [PMID: 35775630 DOI: 10.1039/d2lc00122e] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Electroporation is a fundamental technique for applications in biotechnology. To date, the ongoing research on cell membrane electroporation has explored its mechanism, principles and potential applications. Therefore, in this review, we first discuss the primary electroporation mechanism to help establish a clear framework. Within the context of its principles, several critical terms are highlighted to present a better understanding of the theory of aqueous pores. Different degrees of electroporation can be used in different applications. Thus, we discuss the electric factors (shock strength, shock duration, and shock frequency) responsible for the degree of electroporation. In addition, finding an effective electroporation detection method is of great significance to optimize electroporation experiments. Accordingly, we summarize several primary electroporation detection methods in the following sections. Finally, given the development of micro- and nano-technology has greatly promoted the innovation of microfluidic-based electroporation devices, we also present the recent advances in microfluidic-based electroporation devices. Also, the challenges and outlook of the electroporation technique for cell membrane electroporation are presented.
Collapse
Affiliation(s)
- Fei Wang
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China.
- Shanghai Engineering Research Centre for Intelligent Diagnosis and Treatment Instrument, Shanghai 200240, P. R. China
- Key Lab. for Thin Film and Microfabrication Technology of Ministry of Education, Shanghai 200240, P. R. China
| | - Shujing Lin
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China.
- Shanghai Engineering Research Centre for Intelligent Diagnosis and Treatment Instrument, Shanghai 200240, P. R. China
- Key Lab. for Thin Film and Microfabrication Technology of Ministry of Education, Shanghai 200240, P. R. China
| | - Zixian Yu
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China.
- Shanghai Engineering Research Centre for Intelligent Diagnosis and Treatment Instrument, Shanghai 200240, P. R. China
- Key Lab. for Thin Film and Microfabrication Technology of Ministry of Education, Shanghai 200240, P. R. China
| | - Yanpu Wang
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China.
- Shanghai Engineering Research Centre for Intelligent Diagnosis and Treatment Instrument, Shanghai 200240, P. R. China
- Key Lab. for Thin Film and Microfabrication Technology of Ministry of Education, Shanghai 200240, P. R. China
| | - Di Zhang
- Centre for Advanced Electronic Materials and Devices (AEMD), Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Chengxi Cao
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China.
- Shanghai Engineering Research Centre for Intelligent Diagnosis and Treatment Instrument, Shanghai 200240, P. R. China
| | - Zhigang Wang
- Department of General Surgery, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Daxiang Cui
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China.
- Shanghai Engineering Research Centre for Intelligent Diagnosis and Treatment Instrument, Shanghai 200240, P. R. China
- Key Lab. for Thin Film and Microfabrication Technology of Ministry of Education, Shanghai 200240, P. R. China
| | - Di Chen
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China.
- Shanghai Engineering Research Centre for Intelligent Diagnosis and Treatment Instrument, Shanghai 200240, P. R. China
- Key Lab. for Thin Film and Microfabrication Technology of Ministry of Education, Shanghai 200240, P. R. China
| |
Collapse
|
10
|
Scuderi M, Dermol-Černe J, Amaral da Silva C, Muralidharan A, Boukany PE, Rems L. Models of electroporation and the associated transmembrane molecular transport should be revisited. Bioelectrochemistry 2022; 147:108216. [DOI: 10.1016/j.bioelechem.2022.108216] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 07/19/2022] [Accepted: 07/20/2022] [Indexed: 01/04/2023]
|
11
|
Bregigeon P, Rivière C, Franqueville L, Vollaire C, Marchalot J, Frénéa-Robin M. Integrated platform for culture, observation, and parallelized electroporation of spheroids. LAB ON A CHIP 2022; 22:2489-2501. [PMID: 35475509 DOI: 10.1039/d2lc00074a] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Reversible electroporation is a method to introduce molecules into cells by increasing the permeability of their membranes, thanks to the application of pulsed electric fields. One of its main biomedical applications is electro-chemotherapy, where electroporation is used to deliver anticancer drugs into tumor tissues. To improve our understanding of the electroporation effect on tissues and select efficient treatments, in vitro tumor models are needed. Cell spheroids are relevant models as they can reproduce tumor microenvironment and cell-cell interactions better than 2D cell cultures. Various methods offering a relatively simple workflow are now available for their production. However, electroporation protocols usually require handling steps that may damage spheroids and result in random spacing, inducing variations in electric field distribution around spheroids and non-reproducible electroporation conditions. In addition, only a few microsystems allow the production and electroporation of spheroids, and the spheroids produced lack reproducibility in size and location. To overcome these issues, we developed a unique device enabling culture, monitoring, and electroporation of hundreds of regular spheroids in parallel, with a design ensuring that all spheroids are submitted to the same electric field conditions. It is comprised of a microfluidic chamber encompassing a micro-structured agarose gel, allowing easy medium exchange while avoiding spheroid handling. It also enables optical imaging of spheroids in situ, thanks to transparent electrodes. In this paper, we describe the fabrication and characterization of the developed microsystem and demonstrate its applicability to electroporation of a network of spheroids. We present a first successful application as an anticancer drug testing platform, by evaluating the bleomycin effect on HT29 colorectal cancer cell spheroids. This work opens new perspectives in the development of in vitro assays for the preclinical evaluation of electroporation-based treatment.
Collapse
Affiliation(s)
- Pauline Bregigeon
- Univ Lyon, Ecole Centrale de Lyon, INSA Lyon, Université Claude Bernard Lyon 1, CNRS, Ampère, UMR5005, 69130 Ecully, France.
| | - Charlotte Rivière
- Univ Lyon, Université Claude Bernard Lyon 1, CNRS, Institut Lumière Matière, F-69622, Villeurbanne, France
- Institut Universitaire de France (IUF), France
- Institut Convergence PLAsCAN, Centre de Cancérologie de Lyon, INSERM U1052-CNRS UMR5286, Université de Lyon, Université Claude Bernard Lyon 1, Centre Léon Bérard, Lyon, France
| | - Laure Franqueville
- Univ Lyon, Ecole Centrale de Lyon, INSA Lyon, Université Claude Bernard Lyon 1, CNRS, Ampère, UMR5005, 69130 Ecully, France.
| | - Christian Vollaire
- Univ Lyon, Ecole Centrale de Lyon, INSA Lyon, Université Claude Bernard Lyon 1, CNRS, Ampère, UMR5005, 69130 Ecully, France.
| | - Julien Marchalot
- Univ Lyon, Ecole Centrale de Lyon, INSA Lyon, Université Claude Bernard Lyon 1, CNRS, Ampère, UMR5005, 69130 Ecully, France.
| | - Marie Frénéa-Robin
- Univ Lyon, Ecole Centrale de Lyon, INSA Lyon, Université Claude Bernard Lyon 1, CNRS, Ampère, UMR5005, 69130 Ecully, France.
| |
Collapse
|
12
|
Pulsed Electric Fields for Valorization of Platelets with No Therapeutic Value towards a High Biomedical Potential Product—A Proof of Concept. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12125773] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Nowadays, the standard media used in clinical-scale mesenchymal stem cell (MSC) production to supply hundreds of clinical trials uses animal-derived components as supplements, which raises several health concerns. Consequently, the development of xeno-free media supplements has emerged. In the current study, the effect of pulse electric field (PEF) application to platelet concentrates (PC) with no therapeutic value for producing platelet releasates (PR) able to sustain the ability of bone marrow-MSCs (BM-MSCs) to self-renew and differentiate was tested. It was demonstrated that PEF application to PC induces platelet activation and growth factor (GF) release, namely PDGF, FGF, IGF, and TGF-β. The highest GF release was observed for TGF-β, achieving similar levels to those attained in platelet lysates (PL). BM-MSCs expanded in the presence of PR obtained by the application of PEF (7 pulses of 10 and 12.5 kV/cm) to PC (PR PEF) retained the characteristic MSC cell-surface markers, and the ability to proliferate and differentiate into osteogenic, adipogenic, and chondrogenic lineages. In this study, evidence is provided that PR PEF represents a suitable alternative to fetal bovine serum (FBS) for use in MSC production.
Collapse
|
13
|
Sugrue A, Maor E, Del-Carpio Munoz F, Killu AM, Asirvatham SJ. Cardiac ablation with pulsed electric fields: principles and biophysics. Europace 2022; 24:1213-1222. [PMID: 35426908 DOI: 10.1093/europace/euac033] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 02/24/2022] [Indexed: 01/04/2023] Open
Abstract
Pulsed electric fields (PEFs) have emerged as an ideal cardiac ablation modality. At present numerous clinical trials in humans are exploring PEF as an ablation strategy for both atrial and ventricular arrhythmias, with early data showing significant promise. As this is a relatively new technology there is limited understanding of its principles and biophysics. Importantly, PEF biophysics and principles are starkly different to current energy modalities (radiofrequency and cryoballoon). Given the relatively novel nature of PEFs, this review aims to provide an understanding of the principles and biophysics of PEF ablation. The goal is to enhance academic research and ultimately enable optimization of ablation parameters to maximize procedure success and minimize risk.
Collapse
Affiliation(s)
- Alan Sugrue
- Division of Heart Rhythm Services, Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
- Division of Cardiovascular Medicine, Department of Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Elad Maor
- Division of Heart Rhythm Services, Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
- Chaim Sheba Medical Center and Sackler School of Medicine, Tel Aviv University, Israel
| | - Freddy Del-Carpio Munoz
- Division of Heart Rhythm Services, Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Ammar M Killu
- Division of Heart Rhythm Services, Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Samuel J Asirvatham
- Division of Heart Rhythm Services, Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
14
|
Abstract
In-cell structural biology aims at extracting structural information about proteins or nucleic acids in their native, cellular environment. This emerging field holds great promise and is already providing new facts and outlooks of interest at both fundamental and applied levels. NMR spectroscopy has important contributions on this stage: It brings information on a broad variety of nuclei at the atomic scale, which ensures its great versatility and uniqueness. Here, we detail the methods, the fundamental knowledge, and the applications in biomedical engineering related to in-cell structural biology by NMR. We finally propose a brief overview of the main other techniques in the field (EPR, smFRET, cryo-ET, etc.) to draw some advisable developments for in-cell NMR. In the era of large-scale screenings and deep learning, both accurate and qualitative experimental evidence are as essential as ever to understand the interior life of cells. In-cell structural biology by NMR spectroscopy can generate such a knowledge, and it does so at the atomic scale. This review is meant to deliver comprehensive but accessible information, with advanced technical details and reflections on the methods, the nature of the results, and the future of the field.
Collapse
Affiliation(s)
- Francois-Xavier Theillet
- Université Paris-Saclay, CEA, CNRS, Institute for Integrative Biology of the Cell (I2BC), 91198 Gif-sur-Yvette, France
| |
Collapse
|
15
|
Becker SM. Theoretical model of the influence of irreversibly electroporated cells on post pulse drug delivery to reversibly electroporated cells. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2022; 38:e3564. [PMID: 34913266 DOI: 10.1002/cnm.3564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 12/06/2021] [Accepted: 12/10/2021] [Indexed: 06/14/2023]
Abstract
This study numerically investigates the drug uptake by a population that includes both reversibly and irreversibly electroporated cells. A theoretical continuum model is developed and simulations are conducted in conditions representing low porosity (cells in tissues) and high porosity (cells in suspension). This model considers only passive diffusion following the electroporation pulse and estimates the permeability increases of reversibly electroporated cells using empirically based predictions that relate the long-lived electropore density to the electric field magnitude. A parametric study investigates whether the permeability and resealing rate of irreversibly electroporated cells influence the delivery to the surviving reversibly electroporated cells. The results show that this influence is negligible when the cell number density is low (cells in dilute suspensions). For conditions of cells in tissue when both the fraction of the total cells that are irreversibly electroporated and the permeability of the irreversibly electroporated cells are high enough, the irreversibly electroporated cells rapidly take up the drug and deplete the extracellular space of the available drug. This lowered extracellular concentration can result in less drug delivery to reversibly electroporated cells.
Collapse
Affiliation(s)
- Sid M Becker
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| |
Collapse
|
16
|
Rems L, Tang X, Zhao F, Pérez-Conesa S, Testa I, Delemotte L. Identification of electroporation sites in the complex lipid organization of the plasma membrane. eLife 2022; 11:e74773. [PMID: 35195069 PMCID: PMC8912918 DOI: 10.7554/elife.74773] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Accepted: 02/22/2022] [Indexed: 11/13/2022] Open
Abstract
The plasma membrane of a biological cell is a complex assembly of lipids and membrane proteins, which tightly regulate transmembrane transport. When a cell is exposed to strong electric field, the membrane integrity becomes transiently disrupted by formation of transmembrane pores. This phenomenon termed electroporation is already utilized in many rapidly developing applications in medicine including gene therapy, cancer treatment, and treatment of cardiac arrhythmias. However, the molecular mechanisms of electroporation are not yet sufficiently well understood; in particular, it is unclear where exactly pores form in the complex organization of the plasma membrane. In this study, we combine coarse-grained molecular dynamics simulations, machine learning methods, and Bayesian survival analysis to identify how formation of pores depends on the local lipid organization. We show that pores do not form homogeneously across the membrane, but colocalize with domains that have specific features, the most important being high density of polyunsaturated lipids. We further show that knowing the lipid organization is sufficient to reliably predict poration sites with machine learning. Additionally, by analysing poration kinetics with Bayesian survival analysis we show that poration does not depend solely on local lipid arrangement, but also on membrane mechanical properties and the polarity of the electric field. Finally, we discuss how the combination of atomistic and coarse-grained molecular dynamics simulations, machine learning methods, and Bayesian survival analysis can guide the design of future experiments and help us to develop an accurate description of plasma membrane electroporation on the whole-cell level. Achieving this will allow us to shift the optimization of electroporation applications from blind trial-and-error approaches to mechanistic-driven design.
Collapse
Affiliation(s)
- Lea Rems
- KTH Royal Institute of Technology, Dept. Applied Physics, Science for Life LaboratorySolnaSweden
- University of Ljubljana, Faculty of Electrical EngineeringLjubljanaSlovenia
| | - Xinru Tang
- KTH Royal Institute of Technology, Dept. Applied Physics, Science for Life LaboratorySolnaSweden
- University of Chinese Academy of SciencesBeijingChina
| | - Fangwei Zhao
- KTH Royal Institute of Technology, Dept. Applied Physics, Science for Life LaboratorySolnaSweden
- University of Chinese Academy of SciencesBeijingChina
| | - Sergio Pérez-Conesa
- KTH Royal Institute of Technology, Dept. Applied Physics, Science for Life LaboratorySolnaSweden
| | - Ilaria Testa
- KTH Royal Institute of Technology, Dept. Applied Physics, Science for Life LaboratorySolnaSweden
| | - Lucie Delemotte
- KTH Royal Institute of Technology, Dept. Applied Physics, Science for Life LaboratorySolnaSweden
| |
Collapse
|
17
|
Cytotoxicity of a Cell Culture Medium Treated with a High-Voltage Pulse Using Stainless Steel Electrodes and the Role of Iron Ions. MEMBRANES 2022; 12:membranes12020184. [PMID: 35207105 PMCID: PMC8877239 DOI: 10.3390/membranes12020184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Revised: 01/31/2022] [Accepted: 02/02/2022] [Indexed: 02/01/2023]
Abstract
High-voltage pulses applied to a cell suspension cause not only cell membrane permeabilization, but a variety of electrolysis reactions to also occur at the electrode–solution interfaces. Here, the cytotoxicity of a culture medium treated by a single electric pulse and the role of the iron ions in this cytotoxicity were studied in vitro. The experiments were carried out on mouse hepatoma MH-22A, rat glioma C6, and Chinese hamster ovary cells. The cell culture medium treated with a high-voltage pulse was highly cytotoxic. All cells died in the medium treated by a single electric pulse with a duration of 2 ms and an amplitude of just 0.2 kV/cm. The medium treated with a shorter pulse was less cytotoxic. The cell viability was inversely proportional to the amount of electric charge that flowed through the solution. The amount of iron ions released from the stainless steel anode (>0.5 mM) was enough to reduce cell viability. However, iron ions were not the sole reason of cell death. To kill all MH-22A and CHO cells, the concentration of Fe3+ ions in a medium of more than 2 mM was required.
Collapse
|
18
|
Dijk G, Poulkouras R, OConnor RP. Electroporation Microchip with Integrated Conducting Polymer Electrode Array for Highly Sensitive Impedance Measurement. IEEE Trans Biomed Eng 2022; 69:2363-2369. [PMID: 35041593 DOI: 10.1109/tbme.2022.3143542] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE Monitoring of impedance changes during electroporation-based treatments can be used to study the biological response and provide feedback regarding treatment progression. However, seamless integration of the sensing electrodes with the setup can be challenging and high impedance sensing electrodes limit the recording sensitivity as well as the spatial resolution. Here, we present an all-in-one microchip containing stimulation electrodes, as well as an array of low impedance, micro-scale sensing electrodes for highly sensitive electrical impedance spectroscopy. METHODS An in vitro platform is fabricated with integrated stimulation and sensing electrodes. To reduce the impedance, the sensing electrodes are coated with the conducting polymer PEDOT:PSS. The performance is studied during the growth of a confluent cell layer and treatment with electrical pulses. RESULTS Coated electrodes, compared to uncoated electrodes, show more pronounced impedance changes in a broader frequency range throughout the formation of a confluent cell layer and electrical treatment. CONCLUSION PEDOT:PSS coatings enhance monitoring of impedance changes with micro-scale electrodes, enabling high spatial resolution and increased sensitivity. SIGNIFICANCE Enhanced monitoring techniques can be utilized to study electroporation dynamics and monitor treatment progression for better understanding of underlying mechanisms and improved outcomes.
Collapse
|
19
|
Perera-Bel E, Mercadal B, Garcia-Sanchez T, Gonzalez Ballester MA, Ivorra A. Modeling methods for treatment planning in overlapping electroporation treatments. IEEE Trans Biomed Eng 2021; 69:1318-1327. [PMID: 34559631 DOI: 10.1109/tbme.2021.3115029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Irreversible electroporation (IRE) is a non thermal tissue ablation therapy which is induced by applying high voltage waveforms across electrode pairs. When multiple electrode pairs are sequentially used, the treatment volume (TV) is typically computed as the geometric union of the TVs of individual pairs. However, this method neglects that some regions are exposed to overlapping treatments. Recently, a model describing cell survival probability was introduced which effectively predicted TV with overlapping fields in vivo. However, treatment overlap has yet to be quantified. This study characterizes TV overlap in a controlled in vitro setup with the two existing methods which are compared to an adapted logistic model proposed here. METHODS CHO cells were immobilized in agarose gel. Initially, we characterized the electric field threshold and the cell survival probability for overlapping treatments. Subsequently, we created a 2D setup where we compared and validated the accuracy of the different methods in predicting the TV. RESULTS Overlap can reduce the electric field threshold required to induce cell death, particularly for treatments with low pulse number. However, it does not have a major impact on TV in the models assayed here, and all the studied methods predict TV with similar accuracy. CONCLUSION Treatment overlap has a minor influence in the TV for typical protocols found in IRE therapies. SIGNIFICANCE This study provides evidence that the modeling method used in most pre-clinical and clinical studies seems adequate.
Collapse
|
20
|
Rahman NAA, Jamil MMA, Adon MN, Zainal AB, Javid F, Youseffi M. Fundamental Study of Cannabidiol Effect on MCF-7 with Low Voltage Pulse Electric Field. 2021 11TH IEEE INTERNATIONAL CONFERENCE ON CONTROL SYSTEM, COMPUTING AND ENGINEERING (ICCSCE) 2021. [DOI: 10.1109/iccsce52189.2021.9530885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
21
|
Meglič SH, Pavlin M. The impact of impaired DNA mobility on gene electrotransfer efficiency: analysis in 3D model. Biomed Eng Online 2021; 20:85. [PMID: 34419072 PMCID: PMC8379608 DOI: 10.1186/s12938-021-00922-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Accepted: 08/09/2021] [Indexed: 11/21/2022] Open
Abstract
Background Gene electrotransfer is an established method that enables transfer of DNA into cells with electric pulses. Several studies analyzed and optimized different parameters of gene electrotransfer, however, one of main obstacles toward efficient electrotransfection in vivo is relatively poor DNA mobility in tissues. Our aim was to analyze the effect of impaired mobility on gene electrotransfer efficiency experimentally and theoretically. We applied electric pulses with different durations on plated cells, cells grown on collagen layer and cells embedded in collagen gel (3D model) and analyzed gene electrotransfer efficiency. In order to analyze the effect of impaired mobility on gene electrotransfer efficiency, we applied electric pulses with different durations on plated cells, cells grown on collagen layer and cells embedded in collagen gel (3D model) and analyzed gene electrotransfer efficiency. Results We obtained the highest transfection in plated cells, while transfection efficiency of embedded cells in 3D model was lowest, similarly as in in vivo. To further analyze DNA diffusion in 3D model, we applied DNA on top or injected it into 3D model and showed, that for the former gene electrotransfer efficiency was similarly as in in vivo. The experimental results are explained with theoretical analysis of DNA diffusion and electromobility. Conclusion We show, empirically and theoretically that DNA has impaired electromobility and especially diffusion in collagen environment, where the latter crucially limits electrotransfection. Our model enables optimization of gene electrotransfer in in vitro conditions.
Collapse
Affiliation(s)
- Saša Haberl Meglič
- Faculty of Electrical Engineering, Laboratory of Biocybernetics, University of Ljubljana, Tržaška 25, 1000, Ljubljana, Slovenia
| | - Mojca Pavlin
- Faculty of Medicine, Institute of Biophysics, University of Ljubljana, Vrazov trg 2, 1000, Ljubljana, Slovenia. .,Faculty of Electrical Engineering, Group for Nano and Biotechnological Applications, University of Ljubljana, Tržaška 25, 1000, Ljubljana, Slovenia.
| |
Collapse
|
22
|
Batista Napotnik T, Polajžer T, Miklavčič D. Cell death due to electroporation - A review. Bioelectrochemistry 2021; 141:107871. [PMID: 34147013 DOI: 10.1016/j.bioelechem.2021.107871] [Citation(s) in RCA: 148] [Impact Index Per Article: 49.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 05/12/2021] [Accepted: 06/03/2021] [Indexed: 12/15/2022]
Abstract
Exposure of cells to high voltage electric pulses increases transiently membrane permeability through membrane electroporation. Electroporation can be reversible and is used in gene transfer and enhanced drug delivery but can also lead to cell death. Electroporation resulting in cell death (termed as irreversible electroporation) has been successfully used as a new non-thermal ablation method of soft tissue such as tumours or arrhythmogenic heart tissue. Even though the mechanisms of cell death can influence the outcome of electroporation-based treatments due to use of different electric pulse parameters and conditions, these are not elucidated yet. We review the mechanisms of cell death after electroporation reported in literature, cell injuries that may lead to cell death after electroporation and membrane repair mechanisms involved. The knowledge of membrane repair and cell death mechanisms after cell exposure to electric pulses, targets of electric field in cells need to be identified to optimize existing and develop of new electroporation-based techniques used in medicine, biotechnology, and food technology.
Collapse
Affiliation(s)
- Tina Batista Napotnik
- University of Ljubljana, Faculty of Electrical Engineering, Tržaška cesta 25, 1000 Ljubljana, Slovenia
| | - Tamara Polajžer
- University of Ljubljana, Faculty of Electrical Engineering, Tržaška cesta 25, 1000 Ljubljana, Slovenia
| | - Damijan Miklavčič
- University of Ljubljana, Faculty of Electrical Engineering, Tržaška cesta 25, 1000 Ljubljana, Slovenia.
| |
Collapse
|
23
|
Carr L, Golzio M, Orlacchio R, Alberola G, Kolosnjaj-Tabi J, Leveque P, Arnaud-Cormos D, Rols MP. A nanosecond pulsed electric field (nsPEF) can affect membrane permeabilization and cellular viability in a 3D spheroids tumor model. Bioelectrochemistry 2021; 141:107839. [PMID: 34020398 DOI: 10.1016/j.bioelechem.2021.107839] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 05/03/2021] [Accepted: 05/05/2021] [Indexed: 12/01/2022]
Abstract
Three-dimensional (3D) cellular models represent more realistically the complexity of in vivo tumors compared to 2D cultures. While 3D models were largely used in classical electroporation, the effects of nanosecond pulsed electric field (nsPEF) have been poorly investigated. In this study, we evaluated the biological effects induced by nsPEF on spheroid tumor model derived from the HCT-116 human colorectal carcinoma cell line. By varying the number of pulses (from 1 to 500) and the polarity (unipolar and bipolar), the response of nsPEF exposure (10 ns duration, 50 kV/cm) was assessed either immediately after the application of the pulses or over a period lasting up to 6 days. Membrane permeabilization and cellular death occurred following the application of at least 100 pulses. The extent of the response increased with the number of pulses, with a significant decrease of viability, 24 h post-exposure, when 250 and 500 pulses were applied. The effects were highly reduced when an equivalent number of bipolar pulses were delivered. This reduction was eliminated when a 100 ns interphase interval was introduced into the bipolar pulses. Altogether, our results show that nsPEF effects, previously observed at the single cell level, also occur in more realistic 3D tumor spheroids models.
Collapse
Affiliation(s)
- Lynn Carr
- Univ. Limoges, CNRS, XLIM, UMR 7252, F-87000 Limoges, France; School of Electronic Engineering, Bangor University, Bangor, UK
| | - Muriel Golzio
- Institut de Pharmacologie et de Biologie Structurale, Université de Toulouse, CNRS, UPS, 31077 Toulouse, France
| | - Rosa Orlacchio
- Univ. Limoges, CNRS, XLIM, UMR 7252, F-87000 Limoges, France
| | - Geraldine Alberola
- Institut de Pharmacologie et de Biologie Structurale, Université de Toulouse, CNRS, UPS, 31077 Toulouse, France
| | - Jelena Kolosnjaj-Tabi
- Institut de Pharmacologie et de Biologie Structurale, Université de Toulouse, CNRS, UPS, 31077 Toulouse, France
| | | | - Delia Arnaud-Cormos
- Univ. Limoges, CNRS, XLIM, UMR 7252, F-87000 Limoges, France; Institut Universitaire de France (IUF), 75005 Paris, France.
| | - Marie-Pierre Rols
- Institut de Pharmacologie et de Biologie Structurale, Université de Toulouse, CNRS, UPS, 31077 Toulouse, France.
| |
Collapse
|
24
|
Vižintin A, Marković S, Ščančar J, Miklavčič D. Electroporation with nanosecond pulses and bleomycin or cisplatin results in efficient cell kill and low metal release from electrodes. Bioelectrochemistry 2021; 140:107798. [PMID: 33743336 DOI: 10.1016/j.bioelechem.2021.107798] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 02/19/2021] [Accepted: 03/01/2021] [Indexed: 12/21/2022]
Abstract
Nanosecond electric pulses have several potential advantages in electroporation-based procedures over the conventional micro- and millisecond pulses including low level of heating, reduced electrochemical reactions and reduced muscle contractions making them alluring for use in biomedicine and food industry. The aim of this study was to evaluate if nanosecond pulses can enhance the cytotoxicity of chemotherapeutics bleomycin and cisplatin in vitro and to quantify metal release from electrodes in comparison to 100 μs pulses commonly used in electrochemotherapy. The effects of nanosecond pulse parameters (voltage, pulse duration, number of pulses) on cell membrane permeabilization, resealing and on cell survival after electroporation only and after electrochemotherapy with bleomycin and cisplatin were evaluated on Chinese hamster ovary cells. Application of permeabilizing nanosecond pulses in combination with chemotherapeutics resulted in successful cell kill. Higher extracellular concentrations of bleomycin - but not cisplatin - were needed to achieve the same decrease in cell survival with nanosecond pulses as with eight 100 μs pulses, however, the tested bleomycin concentrations were still considerably lower compared to doses used in clinical practice. Decreasing the pulse duration from microseconds to nanoseconds and concomitantly increasing the amplitude to achieve the same biological effect resulted in reduced release of aluminum ions from electroporation cuvettes.
Collapse
Affiliation(s)
- Angelika Vižintin
- University of Ljubljana, Faculty of Electrical Engineering, Tržaška cesta 25, 1000 Ljubljana, Slovenia
| | - Stefan Marković
- Jožef Stefan Institute, Department of Environmental Sciences, Jamova cesta 39, 1000 Ljubljana, Slovenia
| | - Janez Ščančar
- Jožef Stefan Institute, Department of Environmental Sciences, Jamova cesta 39, 1000 Ljubljana, Slovenia
| | - Damijan Miklavčič
- University of Ljubljana, Faculty of Electrical Engineering, Tržaška cesta 25, 1000 Ljubljana, Slovenia.
| |
Collapse
|
25
|
Hebisch E, Hjort M, Volpati D, Prinz CN. Nanostraw-Assisted Cellular Injection of Fluorescent Nanodiamonds via Direct Membrane Opening. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2006421. [PMID: 33502091 DOI: 10.1002/smll.202006421] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 12/16/2020] [Indexed: 06/12/2023]
Abstract
Due to their stable fluorescence, biocompatibility, and amenability to functionalization, fluorescent nanodiamonds (FND) are promising materials for long term cell labeling and tracking. However, transporting them to the cytosol remains a major challenge, due to low internalization efficiencies and endosomal entrapment. Here, nanostraws in combination with low voltage electroporation pulses are used to achieve direct delivery of FND to the cytosol. The nanostraw delivery leads to efficient and rapid FND transport into cells compared to when incubating cells in a FND-containing medium. Moreover, whereas all internalized FND delivered by incubation end up in lysosomes, a significantly larger proportion of nanostraw-injected FND are in the cytosol, which opens up for using FND as cellular probes. Furthermore, in order to answer the long-standing question in the field of nano-biology regarding the state of the cell membrane on hollow nanostructures, live cell stimulated emission depletion (STED) microscopy is performed to image directly the state of the membrane on nanostraws. The time-lapse STED images reveal that the cell membrane opens entirely on top of nanostraws upon application of gentle electrical pulses, which supports the hypothesis that many FND are delivered directly to the cytosol, avoiding endocytosis and lysosomal entrapment.
Collapse
Affiliation(s)
- Elke Hebisch
- Division of Solid State Physics and NanoLund, Lund University, Lund, 221 00, Sweden
| | - Martin Hjort
- Division of Solid State Physics and NanoLund, Lund University, Lund, 221 00, Sweden
- Navan Technologies Inc., 733 Industrial Rd, San Carlos, CA, United States
| | - Diogo Volpati
- Division of Solid State Physics and NanoLund, Lund University, Lund, 221 00, Sweden
| | - Christelle N Prinz
- Division of Solid State Physics and NanoLund, Lund University, Lund, 221 00, Sweden
| |
Collapse
|
26
|
Generation of Murine Induced Pluripotent Stem Cells through Transposon-Mediated Reprogramming. Methods Mol Biol 2021; 2454:791-809. [PMID: 33755907 DOI: 10.1007/7651_2021_350] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The seminal discovery of induced pluripotent stem (iPS) cells through ectopic expression of a cocktail of gene factors (OCT4, SOX2, KLF4, and c-MYC) by the group of Yamanaka was a major breakthrough, gained widespread acclaim and garnered much attention in the field of stem cell science. The iPS cells possess most of the characteristics and advantages of embryonic stem (ES) cells without the association of ethical stigma for their derivation. In addition, these cells can give rise to any cell type of the body and thus have tremendous potential for many downstream applications in research and regenerative medicine. The original method requires viral transduction of several reprogramming factors, which may be associated with an increased risk of oncogenicity and insertional mutagenesis. Nonviral methods for generation of iPS cells through somatic cell reprogramming are powerful tools for establishing in vitro disease models, development of new protocols for treatment of different diseases, and creating transgenic mice models. Here, we present a detailed protocol for the generation of transposon-mediated iPS cells from mouse embryonic fibroblasts (MEFs) and give a short overview of the characterization of the generated iPS cell lines.
Collapse
|
27
|
Tivig I, Moisescu MG, Savopol T. Changes in the packing of bilayer lipids triggered by electroporation: real-time measurements on cells in suspension. Bioelectrochemistry 2020; 138:107689. [PMID: 33296789 DOI: 10.1016/j.bioelechem.2020.107689] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 10/16/2020] [Accepted: 10/20/2020] [Indexed: 01/15/2023]
Abstract
Electropermeabilization of the cell membrane is a technique used to facilitate penetration of impermeant molecules into cells. Although there are studies regarding the mechanism of processes occurring after electropermeabilization, the relationship between electropermeabilization and associated phenomena (e.g. generation of reactive oxygen species, endocytosis, lipid peroxidation, etc.) is yet to be elucidated. This work aimed to get information on the changes in the packing of the bilayer lipids and their peroxidation induced by application of electroporation pulses. We used a specially designed system of electrodes which allowed performing electropermeabilization of cells in suspension simultaneously with time-dependent measurements of fluorescence and temperature. The kinetics of membrane packing and production of reactive oxygen species were studied using various conductivity buffers (0.01, 0.04 and 0.14 S/m) and different number of 1 kV/cm bipolar pulses (1-50). Two categories of effects were observed: a thermal effect, consisting in an increased bilayer disorder (a deeper penetration of water into the hydrophobic core), and a nonthermal effect, leading to a higher degree of lipids packing, the latter being attributed to a peroxidation process. An analysis of the permeabilization conditions in which one of these two processes predominates was performed.
Collapse
Affiliation(s)
- Ioan Tivig
- Biophysics and Cellular Biotechnology Dept., University of Medicine and Pharmacy Carol Davila, 8 Eroii Sanitari Blvd., Sector 5, 050474 Bucharest, Romania; Excellence Center for Research in Biophysics and Cellular Biotechnology, University of Medicine and Pharmacy Carol Davila, 8 Eroii Sanitari Blvd., Sector 5, 050474 Bucharest, Romania
| | - Mihaela G Moisescu
- Biophysics and Cellular Biotechnology Dept., University of Medicine and Pharmacy Carol Davila, 8 Eroii Sanitari Blvd., Sector 5, 050474 Bucharest, Romania; Excellence Center for Research in Biophysics and Cellular Biotechnology, University of Medicine and Pharmacy Carol Davila, 8 Eroii Sanitari Blvd., Sector 5, 050474 Bucharest, Romania.
| | - Tudor Savopol
- Biophysics and Cellular Biotechnology Dept., University of Medicine and Pharmacy Carol Davila, 8 Eroii Sanitari Blvd., Sector 5, 050474 Bucharest, Romania; Excellence Center for Research in Biophysics and Cellular Biotechnology, University of Medicine and Pharmacy Carol Davila, 8 Eroii Sanitari Blvd., Sector 5, 050474 Bucharest, Romania
| |
Collapse
|
28
|
Lissandrello CA, Santos JA, Hsi P, Welch M, Mott VL, Kim ES, Chesin J, Haroutunian NJ, Stoddard AG, Czarnecki A, Coppeta JR, Freeman DK, Flusberg DA, Balestrini JL, Tandon V. High-throughput continuous-flow microfluidic electroporation of mRNA into primary human T cells for applications in cellular therapy manufacturing. Sci Rep 2020; 10:18045. [PMID: 33093518 PMCID: PMC7582186 DOI: 10.1038/s41598-020-73755-0] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Accepted: 09/21/2020] [Indexed: 02/08/2023] Open
Abstract
Implementation of gene editing technologies such as CRISPR/Cas9 in the manufacture of novel cell-based therapeutics has the potential to enable highly-targeted, stable, and persistent genome modifications without the use of viral vectors. Electroporation has emerged as a preferred method for delivering gene-editing machinery to target cells, but a major challenge remaining is that most commercial electroporation machines are built for research and process development rather than for large-scale, automated cellular therapy manufacturing. Here we present a microfluidic continuous-flow electrotransfection device designed for precise, consistent, and high-throughput genetic modification of target cells in cellular therapy manufacturing applications. We optimized our device for delivery of mRNA into primary human T cells and demonstrated up to 95% transfection efficiency with minimum impact on cell viability and expansion potential. We additionally demonstrated processing of samples comprising up to 500 million T cells at a rate of 20 million cells/min. We anticipate that our device will help to streamline the production of autologous therapies requiring on the order of 10[Formula: see text]-10[Formula: see text] cells, and that it is well-suited to scale for production of trillions of cells to support emerging allogeneic therapies.
Collapse
Affiliation(s)
| | - Jose A Santos
- The Charles Stark Draper Laboratory, Inc., Cambridge, MA, 02139, USA
| | - Peter Hsi
- The Charles Stark Draper Laboratory, Inc., Cambridge, MA, 02139, USA
| | - Michaela Welch
- The Charles Stark Draper Laboratory, Inc., Cambridge, MA, 02139, USA
| | - Vienna L Mott
- The Charles Stark Draper Laboratory, Inc., Cambridge, MA, 02139, USA
| | - Ernest S Kim
- The Charles Stark Draper Laboratory, Inc., Cambridge, MA, 02139, USA
| | - Jordan Chesin
- The Charles Stark Draper Laboratory, Inc., Cambridge, MA, 02139, USA
| | | | - Aaron G Stoddard
- The Charles Stark Draper Laboratory, Inc., Cambridge, MA, 02139, USA
| | - Andrew Czarnecki
- The Charles Stark Draper Laboratory, Inc., Cambridge, MA, 02139, USA
| | | | - Daniel K Freeman
- The Charles Stark Draper Laboratory, Inc., Cambridge, MA, 02139, USA
| | | | | | - Vishal Tandon
- The Charles Stark Draper Laboratory, Inc., Cambridge, MA, 02139, USA.
| |
Collapse
|
29
|
Jakstys B, Jakutaviciute M, Uzdavinyte D, Satkauskiene I, Satkauskas S. Correlation between the loss of intracellular molecules and cell viability after cell electroporation. Bioelectrochemistry 2020; 135:107550. [DOI: 10.1016/j.bioelechem.2020.107550] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Revised: 05/05/2020] [Accepted: 05/08/2020] [Indexed: 12/16/2022]
|
30
|
Kiełbik A, Szlasa W, Saczko J, Kulbacka J. Electroporation-Based Treatments in Urology. Cancers (Basel) 2020; 12:E2208. [PMID: 32784598 PMCID: PMC7465806 DOI: 10.3390/cancers12082208] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 08/03/2020] [Accepted: 08/05/2020] [Indexed: 02/06/2023] Open
Abstract
The observation that an application of a pulsed electric field (PEF) resulted in an increased permeability of the cell membrane has led to the discovery of the phenomenon called electroporation (EP). Depending on the parameters of the electric current and cell features, electroporation can be either reversible or irreversible. The irreversible electroporation (IRE) found its use in urology as a non-thermal ablative method of prostate and renal cancer. As its mechanism is based on the permeabilization of cell membrane phospholipids, IRE (as well as other treatments based on EP) provides selectivity sparing extracellular proteins and matrix. Reversible EP enables the transfer of genes, drugs, and small exogenous proteins. In clinical practice, reversible EP can locally increase the uptake of cytotoxic drugs such as cisplatin and bleomycin. This approach is known as electrochemotherapy (ECT). Few in vivo and in vitro trials of ECT have been performed on urological cancers. EP provides the possibility of transmission of genes across the cell membrane. As the protocols of gene electrotransfer (GET) over the last few years have improved, EP has become a well-known technique for non-viral cell transfection. GET involves DNA transfection directly to the cancer or the host skin and muscle tissue. Among urological cancers, the GET of several plasmids encoding prostate cancer antigens has been investigated in clinical trials. This review brings into discussion the underlying mechanism of EP and an overview of the latest progress and development perspectives of EP-based treatments in urology.
Collapse
Affiliation(s)
- Aleksander Kiełbik
- Faculty of Medicine, Wroclaw Medical University, 50-367 Wroclaw, Poland; (A.K.); (W.S.)
| | - Wojciech Szlasa
- Faculty of Medicine, Wroclaw Medical University, 50-367 Wroclaw, Poland; (A.K.); (W.S.)
| | - Jolanta Saczko
- Department of Molecular and Cellular Biology, Wroclaw Medical University, 50-556 Wroclaw, Poland;
| | - Julita Kulbacka
- Department of Molecular and Cellular Biology, Wroclaw Medical University, 50-556 Wroclaw, Poland;
| |
Collapse
|
31
|
Pirc E, Reberšek M, Miklavčič D. Functional Requirements and Quality Assurance Necessary for Successful Incorporation of Electroporation-Based Therapies Into Clinical Practice. J Med Device 2020. [DOI: 10.1115/1.4045837] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Abstract
Electroporation-based therapies have a huge potential for implementation into clinical practice in socioeconomically disadvantaged populations. Currently, the price of electroporators and electrodes is relatively high, but custom low budget devices can be developed. In the paper, we describe three most established applications in medicine, with the focus on the basic mechanisms, which should be taken into account during the development process of a clinical electroporator. Also, typical pulse parameters used in each of the described applications are defined. In the second part of the paper, we describe technical functional requirements for a clinical electroporator and safety guidelines, with the focus on medical device standard. At the end of the paper, the focus moves to a more general problematic, such as quality assurance and the importance of measurement during the pulse delivery, which we firmly believe is necessary for successful electroporation.
Collapse
Affiliation(s)
- Eva Pirc
- Laboratory of Biocybernetics, Faculty of Electrical Engineering, University of Ljubljana, Tržaška cesta 25, Ljubljana 1000, Slovenia
| | - Matej Reberšek
- Laboratory of Biocybernetics, Faculty of Electrical Engineering, University of Ljubljana, Tržaška cesta 25, Ljubljana 1000, Slovenia
| | - Damijan Miklavčič
- Laboratory of Biocybernetics, Faculty of Electrical Engineering, University of Ljubljana, Tržaška cesta 25, Ljubljana 1000, Slovenia
| |
Collapse
|
32
|
Capacitive coupling increases the accuracy of cell-specific tumour disruption by electric fields. Bioelectrochemistry 2020; 134:107495. [PMID: 32182566 DOI: 10.1016/j.bioelechem.2020.107495] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Revised: 02/24/2020] [Accepted: 02/24/2020] [Indexed: 01/08/2023]
Abstract
Irreversible electroporation holds great potential for cell-specific lysis due to the size-dependent susceptibility of cells to externally imposed electric fields. Previous attempts at selective cell lysis lead to significant overlap between affected populations and struggle with inconsistent biological outcome. We propose that charge transfer at the electrode-liquid interface is responsible by inducing multifactorial effects originating from both the electric field and electrochemical reactions. A promising remedy is the coating of electrodes with a high-k dielectric layer. The resulting capacitive coupling restores the selective potential of electric field mediated lysis in a microfluidic setup. Initial experiments show the consistent depletion of erythrocytes from whole blood while leaving leukocytes intact. The same is true for the reproducible and selective depletion of Jurkat and MCF-7 cells in a mixture with leukocytes. Unexpectedly, the observed order of lysis cannot be correlated with cell size. This implies that the cellular response to capacitive coupling features a selective characteristic that is different from conventional lysis configurations.
Collapse
|
33
|
Hyder I, Eghbalsaied S, Kues WA. Systematic optimization of square-wave electroporation conditions for bovine primary fibroblasts. BMC Mol Cell Biol 2020; 21:9. [PMID: 32111153 PMCID: PMC7049184 DOI: 10.1186/s12860-020-00254-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Accepted: 02/19/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Gene transfer by electroporation is an established method for the non-viral mediated transfection of mammalian cells. Primary cells pose a particular challenge for electroporation-mediated gene transfer, since they are more vulnerable than immortalized cells, and have a limited proliferative capacity. Improving the gene transfer by using square wave electroporation in difficult to transfect cells, like bovine fetal fibroblasts, is a prerequisite for transgenic and further downstream experiments. RESULTS Here, bovine fetal fibroblasts were used for square-wave electroporation experiments in which the following parameters were systematically tested: electroporation buffer, electroporation temperature, pulse voltage, pulse duration, pulse number, cuvette type and plasmid DNA amount. For the experiments a commercially available square-wave generator was applied. Post electroporation, the bovine fetal fibroblasts were observed after 24 h for viability and reporter expression. The best results were obtained with a single 10 millisecond square-wave pulse of 400 V using 10 μg supercoiled plasmid DNA and 0.3 × 106 cells in 100 μl of Opti-MEM medium in 4 mm cuvettes. Importantly, the electroporation at room temperature was considerably better than with pre-cooled conditions. CONCLUSIONS The optimized electroporation conditions will be relevant for gene transfer experiments in bovine fetal fibroblasts to obtain genetically engineered donor cells for somatic cell nuclear transfer and for reprogramming experiments in this species.
Collapse
Affiliation(s)
- Iqbal Hyder
- Institute of Farm Animal Genetics, Friedrich-Loeffler-Institute, 31535, Neustadt, Germany.,Department of Veterinary Physiology, NTR College of Veterinary Science, Gannavaram, India
| | - Shahin Eghbalsaied
- Institute of Farm Animal Genetics, Friedrich-Loeffler-Institute, 31535, Neustadt, Germany.,Transgenesis Center of Excellence, Isfahan (Khorasgan) branch, Islamic Azad University, Isfahan, Iran
| | - Wilfried A Kues
- Institute of Farm Animal Genetics, Friedrich-Loeffler-Institute, 31535, Neustadt, Germany.
| |
Collapse
|
34
|
Zhou Y, Lu Y, Cheng J, Xu Y. Highly uniform in-situ cell electrotransfection of adherent cultures using grouped interdigitated electrodes. Bioelectrochemistry 2019; 132:107435. [PMID: 31855831 DOI: 10.1016/j.bioelechem.2019.107435] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Revised: 11/23/2019] [Accepted: 11/24/2019] [Indexed: 02/05/2023]
Abstract
Cell electrotransfection is an effective approach for transferring exogenous molecules into living cells by electric stimulation. The existing in-situ electrotransfection micro-devices for adherent cells exhibit the drawbacks of low transfection efficiency and low cell viability. An important reason for these drawbacks is the unequal exposure of cells to the electric field. It was found that cells growing directly below the energized electrodes experience a much lower electric field intensity when compared to the cells growing below the spacing area of the electrodes, resulting in low transfection with a strip-like pattern. Therefore, a new strategy for the in-situ electrotransfection of adherent cells growing in a standard 12-well plate is proposed in this study. By sequentially energizing electrodes arranged in a nested and non-contact manner, the cells were exposed to an overall equal intensity of the electric field, and thus a higher efficiency of transfection was achieved. The seven cell lines transfected using this method exhibited high transfection efficiency and high cell viability, demonstrating the potential for studying gene function.
Collapse
Affiliation(s)
- Yicen Zhou
- State Key Laboratory of Membrane Biology, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Ying Lu
- State Key Laboratory of Membrane Biology, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Jing Cheng
- State Key Laboratory of Membrane Biology, School of Medicine, Tsinghua University, Beijing 100084, China; Center for Precision Medicine, West China Hospital, Sichuan University, Chengdu 610041, China; National Engineering Research Center for Beijing Biochip Technology, Beijing 102206, China.
| | - Youchun Xu
- State Key Laboratory of Membrane Biology, School of Medicine, Tsinghua University, Beijing 100084, China; National Engineering Research Center for Beijing Biochip Technology, Beijing 102206, China.
| |
Collapse
|
35
|
Wimberger T, Peham JR, Ehmoser EK, Wassermann KJ. Controllable cell manipulation in a microfluidic pipette-tip design using capacitive coupling of electric fields. LAB ON A CHIP 2019; 19:3997-4006. [PMID: 31667478 DOI: 10.1039/c9lc00927b] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Systems designed toward cell manipulation by electric fields are inherently challenged by energy dissipation along the electrode-electrolyte interface. A promising remedy is the introduction of high-k electrode passivation, enabling efficient capacitive coupling of electric fields into biological samples. We present the implementation of this strategy in a reusable pipette tip design featuring a 10 μl chamber volume for life science applications. Prototype validation and comparison to conductive gold-coated electrodes reveal a consistent and controllable biological effect that significantly increases the reproducibility of lysis events. The system provides precise descriptions of HEK-293 lysis dependency to variables such as field strength, frequency, and conductivity. Over 80% of cells were reversibly electroporated with minimal electrical lysis over a broad range of field settings. Successful transfection requires exponential decay pulses and showcases how modulating capacitive coupling can advance our understanding of fundamental mechanics in the field of electroporation.
Collapse
Affiliation(s)
- Terje Wimberger
- Austrian Institute of Technology GmbH, Department for Health & Bioresources, Vienna, Austria. and University of Natural Resources and Life Sciences, Department for Nanobiotechnology, Vienna, Austria
| | - Johannes R Peham
- Austrian Institute of Technology GmbH, Department for Health & Bioresources, Vienna, Austria.
| | - Eva-Kathrin Ehmoser
- University of Natural Resources and Life Sciences, Department for Nanobiotechnology, Vienna, Austria
| | - Klemens J Wassermann
- Austrian Institute of Technology GmbH, Department for Health & Bioresources, Vienna, Austria.
| |
Collapse
|
36
|
Fiorentzis M, Viestenz A, Siebolts U, Seitz B, Coupland SE, Heinzelmann J. The Potential Use of Electrochemotherapy in the Treatment of Uveal Melanoma: In Vitro Results in 3D Tumor Cultures and In Vivo Results in a Chick Embryo Model. Cancers (Basel) 2019; 11:cancers11091344. [PMID: 31514412 PMCID: PMC6769976 DOI: 10.3390/cancers11091344] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2019] [Revised: 09/01/2019] [Accepted: 09/09/2019] [Indexed: 12/12/2022] Open
Abstract
Uveal melanoma (UM) is the most common primary intraocular tumor that arises from neoplastic melanocytes in the choroid, iris, and ciliary body. Electrochemotherapy (ECT) has been successfully established for the treatment of skin and soft tissue metastatic lesions, deep-seated tumors of the liver, bone metastases, and unresectable pancreas lesions. The aim of this study was to evaluate the effect of ECT in vitro in 3D spheroid culture systems in primary and metastatic UM cell lines. We also investigated the chick embryo chorioallantoic membrane (CAM) as an in vivo model system for the growth and treatment of UM tumors using ECT. The cytotoxic effect of ECT in 3D spheroids was analyzed seven days following treatment by assessment of the size and MTT [(3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) tetrazolium reduction] assay. The cytotoxicity of ECT after intratumoral or intraarterial administration was evaluated histologically. In vitro and in vivo ECT caused a significant reduction in tumor size and viability compared to electroporation or chemotherapy in both sections of our study. The current results underline the effectiveness of ECT in the treatment of UM and prepare the way for further investigation of its potential application in UM.
Collapse
Affiliation(s)
- Miltiadis Fiorentzis
- Department of Ophthalmology, University Hospital Halle (Saale), Martin-Luther University Halle-Wittenberg, Ernst-Grube-Str. 40, 06120 Halle (Saale), Germany.
| | - Arne Viestenz
- Department of Ophthalmology, University Hospital Halle (Saale), Martin-Luther University Halle-Wittenberg, Ernst-Grube-Str. 40, 06120 Halle (Saale), Germany.
| | - Udo Siebolts
- Department of Pathology, University Hospital Halle (Saale), Martin-Luther University Halle-Wittenberg, Magdeburger Str. 14, 06112 Halle (Saale), Germany.
| | - Berthold Seitz
- Department of Ophthalmology, Saarland University Medical Center, Kirrberger Str. 100, 66421 Homburg/Saar, Germany.
| | - Sarah E Coupland
- Liverpool Ocular Oncology Research Group, Department of Molecular and Clinical Cancer Medicine, Institute of Translational Medicine, University of Liverpool, West Derby Street, Liverpool L7 8TX, UK.
- Liverpool Clinical Laboratories, Royal Liverpool University Hospital, Liverpool L69 3GA, UK.
| | - Joana Heinzelmann
- Department of Ophthalmology, University Hospital Halle (Saale), Martin-Luther University Halle-Wittenberg, Ernst-Grube-Str. 40, 06120 Halle (Saale), Germany.
| |
Collapse
|
37
|
Michel O, Błasiak P, Saczko J, Kulbacka J, Drąg-Zalesińska M, Rzechonek A. Electropermeabilization of metastatic chondrosarcoma cells from primary cell culture. Biotechnol Appl Biochem 2019; 66:945-954. [PMID: 31476023 DOI: 10.1002/bab.1809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2018] [Accepted: 08/20/2019] [Indexed: 11/12/2022]
Abstract
Primary cell cultures are challenging, but reliable model reflecting tumor response in vitro. The study was designed to examine if the increased electropermeabilization can overcame initial drug insensitivity in chondrosarcoma cells from lung metastasis. We established a primary cell culture and evaluated the cytotoxic impact of four drugs-cisplatin (CDDP), camptothecin, 2-methoxyestradiol, and leucovorin calcium (LeuCa). After determination of parameters allowing for electropermeabilization, we performed electrochemotherapy in vitro with the least toxic drugs-CDDP and LeuCa. Although combining CDDP and leucovorin together increased their toxicity and supported apoptosis, application of pulsed electric fields (PEFs) brought no advantage for their efficacy. The study emphasizes the need for introduction of primary cell cultures into studies on pulse electric fields as model frequently less sensitive to PEF-based treatments than continuous cell lines.
Collapse
Affiliation(s)
- Olga Michel
- Department of Medical Biochemistry, Wroclaw Medical University, Wroclaw, Poland
| | - Piotr Błasiak
- Department of Thoracic Surgery, Wroclaw Medical University, Wroclaw, Poland
| | - Jolanta Saczko
- Department of Molecular and Cellular Biology, Wroclaw Medical University, Wroclaw, Poland
| | - Julita Kulbacka
- Department of Molecular and Cellular Biology, Wroclaw Medical University, Wroclaw, Poland
| | - Małgorzata Drąg-Zalesińska
- Division of Histology and Embryology, Department of Human Morphology and Embryology, Wroclaw Medical University, Wroclaw, Poland
| | - Adam Rzechonek
- Department of Thoracic Surgery, Wroclaw Medical University, Wroclaw, Poland
| |
Collapse
|
38
|
García-Sánchez T, Leray I, Ronchetti M, Cadossi R, Mir LM. Impact of the number of electric pulses on cell electrochemotherapy in vitro: Limits of linearity and saturation. Bioelectrochemistry 2019; 129:218-227. [PMID: 31200252 DOI: 10.1016/j.bioelechem.2019.05.021] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Revised: 05/30/2019] [Accepted: 05/31/2019] [Indexed: 01/14/2023]
Abstract
In this study the evolution in the efficiency of electrochemotherapy (reversible electroporation) with pulse number was assessed in vitro. Experiments were performed using 100 μs pulses at different electric field intensities and the chemotherapeutic agent bleomycin. Additionally, electrical impedance spectroscopy measurements were used as a different method to study in real time the changes produced on cells with pulse number during trains of consecutive pulses. Our results show that the relation between pulse number and the observed outcome is complex and difficult to fully characterize. This relation can display a highly linear behaviour up to a certain number of pulses and/or field intensity applied. However, the relation between the number of pulses and the observed outcome always evolves to a saturation or at least a reduction in the electric field effects that is displayed when either electric field intensity or pulse number are increased. An exponential model was found to best describe this relation within the range of experimental conditions considered. Electrical impedance measurements confirmed the results and gave a more precise quantification of this dependence. The study highlights the importance that pulse number has in the electrochemotherapy protocols and establishes some limits in the use of this parameter.
Collapse
Affiliation(s)
- Tomás García-Sánchez
- Vectorology and Anticancer Therapies, UMR 8203, CNRS, Univ. Paris-Sud, Gustave Roussy, Université Paris-Saclay, 94805 Villejuif, France.
| | - Isabelle Leray
- Vectorology and Anticancer Therapies, UMR 8203, CNRS, Univ. Paris-Sud, Gustave Roussy, Université Paris-Saclay, 94805 Villejuif, France
| | | | | | - Lluis M Mir
- Vectorology and Anticancer Therapies, UMR 8203, CNRS, Univ. Paris-Sud, Gustave Roussy, Université Paris-Saclay, 94805 Villejuif, France
| |
Collapse
|
39
|
Kotnik T, Rems L, Tarek M, Miklavčič D. Membrane Electroporation and Electropermeabilization: Mechanisms and Models. Annu Rev Biophys 2019; 48:63-91. [PMID: 30786231 DOI: 10.1146/annurev-biophys-052118-115451] [Citation(s) in RCA: 324] [Impact Index Per Article: 64.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Exposure of biological cells to high-voltage, short-duration electric pulses causes a transient increase in their plasma membrane permeability, allowing transmembrane transport of otherwise impermeant molecules. In recent years, large steps were made in the understanding of underlying events. Formation of aqueous pores in the lipid bilayer is now a widely recognized mechanism, but evidence is growing that changes to individual membrane lipids and proteins also contribute, substantiating the need for terminological distinction between electroporation and electropermeabilization. We first revisit experimental evidence for electrically induced membrane permeability, its correlation with transmembrane voltage, and continuum models of electropermeabilization that disregard the molecular-level structure and events. We then present insights from molecular-level modeling, particularly atomistic simulations that enhance understanding of pore formation, and evidence of chemical modifications of membrane lipids and functional modulation of membrane proteins affecting membrane permeability. Finally, we discuss the remaining challenges to our full understanding of electroporation and electropermeabilization.
Collapse
Affiliation(s)
- Tadej Kotnik
- Faculty of Electrical Engineering, University of Ljubljana, SI-1000 Ljubljana, Slovenia; ,
| | - Lea Rems
- Science for Life Laboratory, Department of Applied Physics, KTH Royal Institute of Technology, 17165 Solna, Sweden;
| | - Mounir Tarek
- Université de Lorraine, CNRS, LPCT, F-54000 Nancy, France;
| | - Damijan Miklavčič
- Faculty of Electrical Engineering, University of Ljubljana, SI-1000 Ljubljana, Slovenia; ,
| |
Collapse
|
40
|
Cronjé TF, Gaynor PT. Electroporation of Ishikawa cells: analysis by flow cytometry. IET Nanobiotechnol 2019; 13:58-65. [PMID: 30964039 PMCID: PMC8676626 DOI: 10.1049/iet-nbt.2018.5194] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2018] [Revised: 07/04/2018] [Accepted: 07/31/2018] [Indexed: 12/25/2022] Open
Abstract
Electroporation facilitates loading of cells with molecules and substances that are normally membrane impermeable. Flow cytometry is used in this study to examine the effects of the application of electroporation-level monopolar electric field pulses of varying electrical field strength on Ishikawa endometrial adenocarcinoma cells. Analysis of the fluorescence versus forward scatter plots corroborates the well-recognised threshold and cell size dependence characteristics of electroporation, but also shows the progression of cell lysis and generation of particulate material. Two 500 µs monopolar rectangular pulses ranging from 1.0 × 105 to 2.5 × 105 V/m were used to electroporate the cells. Electroporation yields (fraction of viable cells exhibiting significant propidium iodide uptake) ranged from 0 to 97%, with viability ranging between 78 and 34% over the electric field strength range tested. The higher electric field strength pulses not only reduced cell viability, but also generated a substantial amount of sub-cellular sized particulate material indicating cells have been physically disrupted enough to create these particles.
Collapse
Affiliation(s)
- Thomas F Cronjé
- Department of Engineering and Architectural Studies, Ara Institute of Canterbury, Christchurch, New Zealand.
| | - Paul T Gaynor
- Department of Electrical and Computer Engineering, University of Canterbury, Christchurch, New Zealand
| |
Collapse
|
41
|
Phonesouk E, Lechevallier S, Ferrand A, Rols MP, Bezombes C, Verelst M, Golzio M. Increasing Uptake of Silica Nanoparticles with Electroporation: From Cellular Characterization to Potential Applications. MATERIALS (BASEL, SWITZERLAND) 2019; 12:E179. [PMID: 30621089 PMCID: PMC6337455 DOI: 10.3390/ma12010179] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Revised: 12/21/2018] [Accepted: 12/29/2018] [Indexed: 12/20/2022]
Abstract
In the fields of biology and medicine, nanoproducts such as nanoparticles (NPs) are specifically interesting as theranostic tools, since they offer the double capacity to locally deliver active drugs and to image exactly where the product is delivered. Among the many described possibilities, silica nanoparticles (SiNPs) represent a good choice because of their ease of synthesis, the possibility of their vast functionalization, and their good biocompatibility. However, SiNPs' passive cell internalization by endocytosis only distributes NPs into the cell cytoplasm and is unable to target the nucleus if SiNPs are larger than a few nanometers. In this study, we demonstrate that the cell penetration of SiNPs of 28⁻30 nm in diameter can be strongly enhanced using a physical method, called electroporation or electropermeabilization (EP). The uptake of fluorescently labelled silica nanoparticles was improved in two different cancer cell lines, namely, HCT-116 (human colon cancer) cells and RL (B-lymphoma) cells. First, we studied cells' capability for the regular passive uptake of SiNPs in vitro. Then, we set EP parameters in order to induce a more efficient and rapid cell loading, also comprising the nuclear compartment, while preserving the cell viability. In the final approach, we performed in vivo experiments, and evidenced that the labeling was long-lasting, as confirmed by fluorescence imaging of labeled tumors, which enabled a 30-day follow-up. This kind of SiNPs delivery, achieved by EP, could be employed to load extensive amounts of active ingredients into the cell nucleus, and concomitantly allow the monitoring of the long-term fate of nanoparticles.
Collapse
Affiliation(s)
- Erick Phonesouk
- Institut de Pharmacologie et de Biologie Structurale-UMR 5089, 205 route de Narbonne, 31077 Toulouse CEDEX 04, France.
- Chromalys SAS, 29 rue jeanne Marvig, 31400 Toulouse, France.
| | | | - Audrey Ferrand
- IRSD, Université de Toulouse, INSERM (U1220), INRA, ENVT, UPS, 31024Toulouse cedex 3, France.
| | - Marie-Pierre Rols
- Institut de Pharmacologie et de Biologie Structurale-UMR 5089, 205 route de Narbonne, 31077 Toulouse CEDEX 04, France.
| | - Christine Bezombes
- UMR1037 INSERM, Université de Toulouse, ERL5294 CNRS, 31100 Toulouse, France.
| | - Marc Verelst
- Chromalys SAS, 29 rue jeanne Marvig, 31400 Toulouse, France.
| | - Muriel Golzio
- Institut de Pharmacologie et de Biologie Structurale-UMR 5089, 205 route de Narbonne, 31077 Toulouse CEDEX 04, France.
| |
Collapse
|
42
|
Mukherjee P, Nathamgari SSP, Kessler JA, Espinosa HD. Combined Numerical and Experimental Investigation of Localized Electroporation-Based Cell Transfection and Sampling. ACS NANO 2018; 12:12118-12128. [PMID: 30452236 PMCID: PMC6535396 DOI: 10.1021/acsnano.8b05473] [Citation(s) in RCA: 69] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/14/2023]
Abstract
Localized electroporation has evolved as an effective technology for the delivery of foreign molecules into cells while preserving their viability. Consequently, this technique has potential applications in sampling the contents of live cells and the temporal assessment of cellular states at the single-cell level. Although there have been numerous experimental reports on localized electroporation-based delivery, a lack of a mechanistic understanding of the process hinders its implementation in sampling. In this work, we develop a multiphysics model that predicts the transport of molecules into and out of the cell during localized electroporation. Based on the model predictions, we optimize experimental parameters such as buffer conditions, electric field strength, cell confluency, and density of nanochannels in the substrate for successful delivery and sampling via localized electroporation. We also identify that cell membrane tension plays a crucial role in enhancing both the amount and the uniformity of molecular transport, particularly for macromolecules. We qualitatively validate the model predictions on a localized electroporation platform by delivering large molecules (bovine serum albumin and mCherry-encoding plasmid) and by sampling an exogeneous protein (tdTomato) in an engineered cell line.
Collapse
Affiliation(s)
- Prithvijit Mukherjee
- Department of Mechanical Engineering, Northwestern University, Evanston, Illinois 60208, United States
- Theoretical and Applied Mechanics Program, Northwestern University, Evanston, Illinois 60208, United States
| | - S. Shiva P. Nathamgari
- Department of Mechanical Engineering, Northwestern University, Evanston, Illinois 60208, United States
- Theoretical and Applied Mechanics Program, Northwestern University, Evanston, Illinois 60208, United States
| | - John A. Kessler
- Department of Neurology, Northwestern University, Chicago, Illinois 60611, United States
| | - Horacio D. Espinosa
- Department of Mechanical Engineering, Northwestern University, Evanston, Illinois 60208, United States
- Theoretical and Applied Mechanics Program, Northwestern University, Evanston, Illinois 60208, United States
| |
Collapse
|
43
|
Stewart MP, Langer R, Jensen KF. Intracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts. Chem Rev 2018; 118:7409-7531. [PMID: 30052023 PMCID: PMC6763210 DOI: 10.1021/acs.chemrev.7b00678] [Citation(s) in RCA: 382] [Impact Index Per Article: 63.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Intracellular delivery is a key step in biological research and has enabled decades of biomedical discoveries. It is also becoming increasingly important in industrial and medical applications ranging from biomanufacture to cell-based therapies. Here, we review techniques for membrane disruption-based intracellular delivery from 1911 until the present. These methods achieve rapid, direct, and universal delivery of almost any cargo molecule or material that can be dispersed in solution. We start by covering the motivations for intracellular delivery and the challenges associated with the different cargo types-small molecules, proteins/peptides, nucleic acids, synthetic nanomaterials, and large cargo. The review then presents a broad comparison of delivery strategies followed by an analysis of membrane disruption mechanisms and the biology of the cell response. We cover mechanical, electrical, thermal, optical, and chemical strategies of membrane disruption with a particular emphasis on their applications and challenges to implementation. Throughout, we highlight specific mechanisms of membrane disruption and suggest areas in need of further experimentation. We hope the concepts discussed in our review inspire scientists and engineers with further ideas to improve intracellular delivery.
Collapse
Affiliation(s)
- Martin P. Stewart
- Department of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, USA
- The Koch Institute for Integrative Cancer Research,
Massachusetts Institute of Technology, Cambridge, USA
| | - Robert Langer
- Department of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, USA
- The Koch Institute for Integrative Cancer Research,
Massachusetts Institute of Technology, Cambridge, USA
| | - Klavs F. Jensen
- Department of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, USA
| |
Collapse
|
44
|
Batista Napotnik T, Miklavčič D. In vitro electroporation detection methods – An overview. Bioelectrochemistry 2018; 120:166-182. [DOI: 10.1016/j.bioelechem.2017.12.005] [Citation(s) in RCA: 109] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2017] [Revised: 12/11/2017] [Accepted: 12/11/2017] [Indexed: 12/22/2022]
|
45
|
Sweeney DC, Weaver JC, Davalos RV. Characterization of Cell Membrane Permeability In Vitro Part I: Transport Behavior Induced by Single-Pulse Electric Fields. Technol Cancer Res Treat 2018; 17:1533033818792491. [PMID: 30236040 PMCID: PMC6154305 DOI: 10.1177/1533033818792491] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 06/18/2018] [Accepted: 07/03/2018] [Indexed: 02/03/2023] Open
Abstract
Most experimental studies of electroporation focus on permeabilization of the outer cell membrane. Some experiments address delivery of ions and molecules into cells that should survive; others focus on efficient killing of the cells with minimal temperature rise. A basic method for quantifying electroporation effectiveness is measuring the membrane's diffusive permeability. More specifically, comparisons of membrane permeability between electroporation protocols often rely on relative fluorescence measurements, which are not able to be directly connected to theoretical calculations and complicate comparisons between studies. Here we present part I of a 2-part study: a research method for quantitatively determining the membrane diffusive permeability for individual cells using fluorescence microscopy. We determine diffusive permeabilities of cell membranes to propidium for electric field pulses with durations of 1 to 1000 μs and strengths of 170 to 400 kV/m and show that diffusive permeabilities can reach 1.3±0.4×10-8 m/s. This leads to a correlation between increased membrane permeability and eventual propidium uptake. We also identify a subpopulation of cells that exhibit a delayed and significant propidium uptake for relatively small single pulses. Our results provide evidence that cells, especially those that uptake propidium more slowly, can achieve large permeabilities with a single electrical pulse that may be quantitatively measured using standard fluorescence microscopy equipment and techniques.
Collapse
Affiliation(s)
- Daniel C. Sweeney
- Department of Biomedical Engineering and Mechanics, Virginia Tech,
Blacksburg, VA, USA
| | - James C. Weaver
- Harvard-MIT Division of Health Sciences and Technology, Massachusetts
Institute of Technology, Cambridge, MA, USA
| | - Rafael V. Davalos
- Department of Biomedical Engineering and Mechanics, Virginia Tech,
Blacksburg, VA, USA
| |
Collapse
|
46
|
Kinio S, Mills JK. Localized Electroporation With Dielectrophoretic Field Flow Fractionation: Toward Removal of Circulating Tumour Cells From Human Blood. IEEE Trans Nanobioscience 2017; 16:802-809. [PMID: 29053456 DOI: 10.1109/tnb.2017.2764380] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This paper presents the design and experimental performance of a microelectrode-based device to selectively lyse cells in a flow in a microfluidic channel. Localized cell lysis is achieved by utilizing "irreversible electroporation," in which cells are exposed to high magnitude electric pulses. Localized cell lysis in a flow has research applications and may allow for the removal of harmful cells, such as circulating tumor cells from blood. Due to the dependence of this technique on the magnitude of the applied electric field, lethal electric field regions can be localized in the channel by the calibration of the applied voltage. Dielectrophoresis field flow fractionation is used to levitate target cancer cells in the lethal region of the device microchannel. Experiments are performed to demonstrate the localized lysis of MCF7 cancer cells in a mixture of blood cells. Due to their larger size, these circulating tumor cell analogues levitate to a greater height in the channel than erythrocytes. MCF7 lysis is observed to increase from 4.6% in control experiments to 57.3% in active experiments. Leukocyte viability was unaffected in active experiments. These results demonstrate the feasibility of localizing cell lysis in a microfluidic flow environment.
Collapse
|
47
|
Hanna H, Denzi A, Liberti M, André FM, Mir LM. Electropermeabilization of Inner and Outer Cell Membranes with Microsecond Pulsed Electric Fields: Quantitative Study with Calcium Ions. Sci Rep 2017; 7:13079. [PMID: 29026094 PMCID: PMC5638809 DOI: 10.1038/s41598-017-12960-w] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2016] [Accepted: 09/15/2017] [Indexed: 12/18/2022] Open
Abstract
Microsecond pulsed electric fields (μsPEF) permeabilize the plasma membrane (PM) and are widely used in research, medicine and biotechnology. For internal membranes permeabilization, nanosecond pulsed electric fields (nsPEF) are applied but this technology is complex to use. Here we report that the endoplasmic reticulum (ER) membrane can also be electropermeabilized by one 100 µs pulse without affecting the cell viability. Indeed, using Ca2+ as a permeabilization marker, we observed cytosolic Ca2+ peaks in two different cell types after one 100 µs pulse in a medium without Ca2+. Thapsigargin abolished these Ca2+ peaks demonstrating that the calcium is released from the ER. Moreover, IP3R and RyR inhibitors did not modify these peaks showing that they are due to the electropermeabilization of the ER membrane and not to ER Ca2+ channels activation. Finally, the comparison of the two cell types suggests that the PM and the ER permeabilization thresholds are affected by the sizes of the cell and the ER. In conclusion, this study demonstrates that µsPEF, which are easier to control than nsPEF, can permeabilize internal membranes. Besides, μsPEF interaction with either the PM or ER, can be an efficient tool to modulate the cytosolic calcium concentration and study Ca2+ roles in cell physiology.
Collapse
Affiliation(s)
- Hanna Hanna
- Vectorology and Anticancer Therapies, UMR 8203, CNRS, Univ. Paris-Sud, Gustave Roussy, Université Paris-Saclay, 94 805, Villejuif, France
| | - Agnese Denzi
- Department of Information Engineering, Electronics and Telecommunication (DIET), University of Rome "La Sapienza", Rome, 00184, Italy
| | - Micaela Liberti
- Department of Information Engineering, Electronics and Telecommunication (DIET), University of Rome "La Sapienza", Rome, 00184, Italy
| | - Franck M André
- Vectorology and Anticancer Therapies, UMR 8203, CNRS, Univ. Paris-Sud, Gustave Roussy, Université Paris-Saclay, 94 805, Villejuif, France
| | - Lluis M Mir
- Vectorology and Anticancer Therapies, UMR 8203, CNRS, Univ. Paris-Sud, Gustave Roussy, Université Paris-Saclay, 94 805, Villejuif, France.
| |
Collapse
|
48
|
Azan A, Untereiner V, Descamps L, Merla C, Gobinet C, Breton M, Piot O, Mir LM. Comprehensive Characterization of the Interaction between Pulsed Electric Fields and Live Cells by Confocal Raman Microspectroscopy. Anal Chem 2017; 89:10790-10797. [DOI: 10.1021/acs.analchem.7b02079] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Antoine Azan
- Vectorology
and Anticancer Therapies, UMR 8203, CNRS, Gustave Roussy, Univ. Paris-Sud, Université Paris-Saclay, 114 rue Edouard Vaillant, 94805 Villejuif, France
| | - Valérie Untereiner
- MeDIAN,
Biophotonics and Technologies for Health, MEDyC, UMR 7369, CNRS, University of Reims Champagne-Ardenne, 51 rue Cognacq Jay, 51096 Reims, France
- Cellular
and Tissular Imaging Platform (PICT), Faculty of Pharmacy, University of Reims Champagne-Ardenne, 51 rue Cognacq Jay, 51096 Reims, France
| | - Lucie Descamps
- Vectorology
and Anticancer Therapies, UMR 8203, CNRS, Gustave Roussy, Univ. Paris-Sud, Université Paris-Saclay, 114 rue Edouard Vaillant, 94805 Villejuif, France
| | - Caterina Merla
- Vectorology
and Anticancer Therapies, UMR 8203, CNRS, Gustave Roussy, Univ. Paris-Sud, Université Paris-Saclay, 114 rue Edouard Vaillant, 94805 Villejuif, France
| | - Cyril Gobinet
- MeDIAN,
Biophotonics and Technologies for Health, MEDyC, UMR 7369, CNRS, University of Reims Champagne-Ardenne, 51 rue Cognacq Jay, 51096 Reims, France
| | - Marie Breton
- Vectorology
and Anticancer Therapies, UMR 8203, CNRS, Gustave Roussy, Univ. Paris-Sud, Université Paris-Saclay, 114 rue Edouard Vaillant, 94805 Villejuif, France
| | - Olivier Piot
- MeDIAN,
Biophotonics and Technologies for Health, MEDyC, UMR 7369, CNRS, University of Reims Champagne-Ardenne, 51 rue Cognacq Jay, 51096 Reims, France
- Cellular
and Tissular Imaging Platform (PICT), Faculty of Pharmacy, University of Reims Champagne-Ardenne, 51 rue Cognacq Jay, 51096 Reims, France
| | - Lluis M. Mir
- Vectorology
and Anticancer Therapies, UMR 8203, CNRS, Gustave Roussy, Univ. Paris-Sud, Université Paris-Saclay, 114 rue Edouard Vaillant, 94805 Villejuif, France
| |
Collapse
|
49
|
Merla C, Pakhomov AG, Semenov I, Vernier PT. Frequency spectrum of induced transmembrane potential and permeabilization efficacy of bipolar electric pulses. BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES 2017; 1859:1282-1290. [DOI: 10.1016/j.bbamem.2017.04.014] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2016] [Revised: 04/12/2017] [Accepted: 04/16/2017] [Indexed: 12/22/2022]
|
50
|
Physical Methods for Drug and Gene Delivery Through the Cell Plasma Membrane. ADVANCES IN ANATOMY EMBRYOLOGY AND CELL BIOLOGY 2017; 227:73-92. [DOI: 10.1007/978-3-319-56895-9_5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|