1
|
Fu P, Li P, Hu Y. A general numerical model of leukocyte adhesion in microchannels. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2022; 38:e3606. [PMID: 35488511 DOI: 10.1002/cnm.3606] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 03/11/2022] [Accepted: 04/19/2022] [Indexed: 06/14/2023]
Abstract
Leukocyte adhesion on the vascular endothelium plays an important role in human immune system and reflects the physiological condition of a human body. In this paper, a generally implementable dynamic adhesion model based on the length limit of microvilli was developed to explore the behavior of a suspended leukocyte's adhesion process under microchannel shear flow. Simulations showed that the whole adhesion process can be divided into cell sedimentation, preliminary adhesion and stable dynamic adhesion stages. The cell tumbling kinetics, cell deformation, cell adhesion area and adhesion force were studied under the conditions of various bond strength, cell membrane surface tension, inlet flow velocity and cytoplasmic viscosity. Results showed that the bond strength affects the cell tumbling behaviors differently by changing the adhesion force. The cell with lower membrane surface tension induces a larger adhesion area, and eventually results in a greater adhesion and a lower cell tumbling velocity. The flow velocity changes cell velocity through the flow viscous force during the whole adhesion process. The cytoplasmic viscosity affects adhesion mainly in the preliminary adhesion stage by changing the cell deformation rate but has slight effect on the stabilized dynamic adhesion on cells. This study provides a simple theoretical basis to further clarify the mechanism of cell behaviors under stress and adhesion and becomes one of the prerequisites for study of tissue inflammation, wound healing, and disease treatments.
Collapse
Affiliation(s)
- Peixin Fu
- State Key Laboratory of Ocean Engineering, School of Naval Architecture, Ocean and Civil Engineering, Collaborative Innovation Center for Advanced Ship and Deep-Sea Exploration, Shanghai Jiao Tong University, Shanghai, China
| | - Peiye Li
- State Key Laboratory of Ocean Engineering, School of Naval Architecture, Ocean and Civil Engineering, Collaborative Innovation Center for Advanced Ship and Deep-Sea Exploration, Shanghai Jiao Tong University, Shanghai, China
| | - Yandong Hu
- State Key Laboratory of Ocean Engineering, School of Naval Architecture, Ocean and Civil Engineering, Collaborative Innovation Center for Advanced Ship and Deep-Sea Exploration, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
2
|
Guo Y, Calve S, Tepole AB. Multiscale mechanobiology: Coupling models of adhesion kinetics and nonlinear tissue mechanics. Biophys J 2022; 121:525-539. [PMID: 35074393 PMCID: PMC8874030 DOI: 10.1016/j.bpj.2022.01.012] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 12/13/2021] [Accepted: 01/18/2022] [Indexed: 11/25/2022] Open
Abstract
The mechanical behavior of tissues at the macroscale is tightly coupled to cellular activity at the microscale. Dermal wound healing is a prominent example of a complex system in which multiscale mechanics regulate restoration of tissue form and function. In cutaneous wound healing, a fibrin matrix is populated by fibroblasts migrating in from a surrounding tissue made mostly out of collagen. Fibroblasts both respond to mechanical cues, such as fiber alignment and stiffness, as well as exert active stresses needed for wound closure. Here, we develop a multiscale model with a two-way coupling between a microscale cell adhesion model and a macroscale tissue mechanics model. Starting from the well-known model of adhesion kinetics proposed by Bell, we extend the formulation to account for nonlinear mechanics of fibrin and collagen and show how this nonlinear response naturally captures stretch-driven mechanosensing. We then embed the new nonlinear adhesion model into a custom finite element implementation of tissue mechanical equilibrium. Strains and stresses at the tissue level are coupled with the solution of the microscale adhesion model at each integration point of the finite element mesh. In addition, solution of the adhesion model is coupled with the active contractile stress of the cell population. The multiscale model successfully captures the mechanical response of biopolymer fibers and gels, contractile stresses generated by fibroblasts, and stress-strain contours observed during wound healing. We anticipate that this framework will not only increase our understanding of how mechanical cues guide cellular behavior in cutaneous wound healing, but will also be helpful in the study of mechanobiology, growth, and remodeling in other tissues.
Collapse
Affiliation(s)
- Yifan Guo
- School of Mechanical Engineering, Purdue University, West Lafayette
| | - Sarah Calve
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette,Paul M. Rady Department of Mechanical Engineering, University of Colorado - Boulder, Boulder
| | - Adrian Buganza Tepole
- School of Mechanical Engineering, Purdue University, West Lafayette; Weldon School of Biomedical Engineering, Purdue University, West Lafayette.
| |
Collapse
|
3
|
Ostrikov K, Kashani MN, Vasilev K, MacGregor MN. Fluid Flow Dependency in Immunoselective Cell Capture via Liquid Biopsy. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2021; 37:12388-12396. [PMID: 34596407 DOI: 10.1021/acs.langmuir.1c01998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Liquid biopsy targets rare cells that overexpress disease-specific membrane markers and capture these cells via immunoaffinity. The diagnosis efficiency of liquid biopsy can be impaired by the presence of healthy adherent cells also expressing the same biomarkers. Here, we investigated the effect of settling times and rinsing flow rates on the efficiency of EpCAM-based immunocapture using both simulation and experiments with three different cell types. Cell-surface adhesion forces and shear rates were calculated to define the range of rinsing flow rates to test experimentally. Healthy adherent cells did not adhere to blocked immunofunctionalized surfaces within the timeframe of the experiment; however, healthy EpCAM positive cells did bind to the surface to some extent. The greatest difference in capture efficiency was obtained using a high rinsing flow rate of 25 mL/min following 40 min static incubation, indicating that optimizing rinsing flow rates could be a viable option to capture, more specifically, cancer cells overexpressing EpCAM.
Collapse
Affiliation(s)
- Kola Ostrikov
- UniSA STEM, University of South Australia, Mawson Lakes 5095, Australia
| | - Moein Navvab Kashani
- UniSA STEM, University of South Australia, Mawson Lakes 5095, Australia
- South Australian Node of the Australian National Fabrication Facility, Mawson Lakes 5095, Australia
| | - Krasimir Vasilev
- UniSA STEM, University of South Australia, Mawson Lakes 5095, Australia
| | | |
Collapse
|
4
|
Bionic Organs: Shear Forces Reduce Pancreatic Islet and Mammalian Cell Viability during the Process of 3D Bioprinting. MICROMACHINES 2021; 12:mi12030304. [PMID: 33799490 PMCID: PMC7999205 DOI: 10.3390/mi12030304] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 03/10/2021] [Accepted: 03/11/2021] [Indexed: 12/17/2022]
Abstract
Background: 3D bioprinting is the future of constructing functional organs. Creating a bioactive scaffold with pancreatic islets presents many challenges. The aim of this paper is to assess how the 3D bioprinting process affects islet viability. Methods: The BioX 3D printer (Cellink), 600 μm inner diameter nozzles, and 3% (w/v) alginate cell carrier solution were used with rat, porcine, and human pancreatic islets. Islets were divided into a control group (culture medium) and 6 experimental groups (each subjected to specific pressure between 15 and 100 kPa). FDA/PI staining was performed to assess the viability of islets. Analogous studies were carried out on α-cells, β-cells, fibroblasts, and endothelial cells. Results: Viability of human pancreatic islets was as follows: 92% for alginate-based control and 94%, 90%, 74%, 48%, 61%, and 59% for 15, 25, 30, 50, 75, and 100 kPa, respectively. Statistically significant differences were observed between control and 50, 75, and 100 kPa, respectively. Similar observations were made for porcine and rat islets. Conclusions: Optimal pressure during 3D bioprinting with pancreatic islets by the extrusion method should be lower than 30 kPa while using 3% (w/v) alginate as a carrier.
Collapse
|
5
|
Zhang Q, Shao Y, Li B, Wu Y, Dong J, Zhang D, Wang Y, Yan Y, Wang X, Pu Q, Guo G. Visually precise, low-damage, single-cell spatial manipulation with single-pixel resolution. Chem Sci 2021; 12:4111-4118. [PMID: 34163682 PMCID: PMC8179525 DOI: 10.1039/d0sc05534d] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
Abstract
The analysis of single living cells, including intracellular delivery and extraction, is essential for monitoring their dynamic biochemical processes and exploring intracellular heterogeneity. However, owing to the 2D view in bright-field microscopy and optical distortions caused by the cell shape and the variation in the refractive index both inside and around the cells, achieving spatially undistorted imaging for high-precision manipulation within a cell is challenging. Here, an accurate and visual system is developed for single-cell spatial manipulation by correcting the aberration for simultaneous bright-field triple-view imaging. Stereo information from the triple view enables higher spatial resolution that facilitates the precise manipulation of single cells. In the bright field, we resolved the spatial locations of subcellular structures of a single cell suspended in a medium and measured the random spatial rotation angle of the cell with a precision of ±5°. Furthermore, we demonstrated the visual manipulation of a probe to an arbitrary spatial point of a cell with an accuracy of <1 pixel. This novel system is more accurate and less destructive for subcellular content extraction and drug delivery. We achieved the low-damage spatial puncture of single cells at specific visual points with an accuracy of <65 nm.![]()
Collapse
Affiliation(s)
- Qi Zhang
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| | - Yunlong Shao
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| | - Boye Li
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| | - Yuanyuan Wu
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| | - Jingying Dong
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| | - Dongtang Zhang
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| | - Yanan Wang
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| | - Yong Yan
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| | - Xiayan Wang
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| | - Qiaosheng Pu
- Department of Chemistry, Lanzhou University Lanzhou Gansu 730000 China
| | - Guangsheng Guo
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Biology, Beijing University of Technology Beijing 100124 China
| |
Collapse
|
6
|
Demirörs AF, Stauffer A, Lauener C, Cossu J, Ramakrishna SN, de Graaf J, Alcantara CCJ, Pané S, Spencer N, Studart AR. Magnetic propulsion of colloidal microrollers controlled by electrically modulated friction. SOFT MATTER 2021; 17:1037-1047. [PMID: 33289746 DOI: 10.1039/d0sm01449d] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Precise control over the motion of magnetically responsive particles in fluidic chambers is important for probing and manipulating tasks in prospective microrobotic and bio-analytical platforms. We have previously exploited such colloids as shuttles for the microscale manipulation of objects. Here, we study the rolling motion of magnetically driven Janus colloids on solid substrates under the influence of an orthogonal external electric field. Electrically induced attractive interactions were used to tune the load on the Janus colloid and thereby the friction with the underlying substrate, leading to control over the forward velocity of the particle. Our experimental data suggest that the frictional coupling required to achieve translation, transitions from a hydrodynamic regime to one of mixed contact coupling with increasing load force. Based on this insight, we show that our colloidal microrobots can probe the local friction coefficient of various solid surfaces, which makes them potentially useful as tribological microsensors. Lastly, we precisely manipulate porous cargos using our colloidal rollers, a feat that holds promise for bio-analytical applications.
Collapse
Affiliation(s)
- Ahmet F Demirörs
- Complex Materials, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Investigating the Interaction Between Circulating Tumor Cells and Local Hydrodynamics via Experiment and Simulations. Cell Mol Bioeng 2020; 13:527-540. [PMID: 33184581 DOI: 10.1007/s12195-020-00656-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Accepted: 09/25/2020] [Indexed: 10/23/2022] Open
Abstract
Introduction The biological and mechanical properties of circulating tumor cells (CTCs) in combination with the hemodynamics affect the preference of metastatic sites in the vasculature. Despite the extensive literature on the effects of biological properties on cell adhesion, the effects of hydrodynamic forces on primary attachment remains an active area of research. Using simulations in conjunction with experimentation, we provide new insight into the interplay of CTCs dynamics and local hydrodynamics. Methods A flow experiment of CTC attachment was performed within a bioprinted, double branching endothelialized vessel. Simulations of fluid flow and CTC transport in the reconstructed and idealized bifurcated vessel were respectively performed by HARVEY, our in-house massively parallel computational fluid dynamics solver. HARVEY is based on the lattice Boltzmann and finite element methods to model the fluid and cells dynamics. The immersed boundary method is employed for resolving the fluid-structure interaction. Results CTC attachment was quantified experimentally at all regions of the complex vessel. The results demonstrate a clear preference for CTCs to attach at the branch points. To elucidate the effect of the vessel topology on the location of attachment, a fluid-only simulation was performed assessing the differences in the hydrodynamics along the vessel. CTC transport in idealized bifurcated vessels was subsequently studied to examine the effects of cell deformability on the local hydrodynamics patterns and, thus, the preference of attachment sites. Conclusions The current work provides evidence on the correlation of the hydrodynamics forces arising from the vessel topology and CTC properties on the attachment regions.
Collapse
|
8
|
In vitro analysis of the trajectories of adhesive microbubbles approaching endothelial cells. J Colloid Interface Sci 2020; 578:758-767. [PMID: 32574909 DOI: 10.1016/j.jcis.2020.06.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 05/30/2020] [Accepted: 06/02/2020] [Indexed: 11/21/2022]
Abstract
Adhesion is a key process when ultrasound contrast agents, i.e. microbubbles, approach pathological tissues. A way to accomplish tumour targeting is to tether surface engineered microbubbles to endothelial cells of the up-regulated vascularization of cancer tissues. This can be achieved by coupling the microbubbles surface with the Arginine-Glycine-Aspartate, RGD, sequence. Such molecule interacts with the integrin receptors placed on the endothelial cells. Stability and trajectories of RGD modified lipid shelled MBs have been analysed in vitro using microchannels coated with human umbilical vein endothelial cells, HUVEC. In the microchannels realistic conditions, close to the physiological ones, were reproduced replicating shear rate, roughness comparable to the endothelium and channel size mimicking the postcapillary venules. In these conditions, the analysis of the trajectories close to the walls highlights a substantial difference between the modified MBs and the plain ones. Moreover, MBs adhesion has dynamic features recalling the motion of neutrophils engaged near the substrate such as rolling, translations and transient detachments. These findings are useful for the optimization of in vivo imaging and targeting functions.
Collapse
|
9
|
Bacon K, Lavoie A, Rao BM, Daniele M, Menegatti S. Past, Present, and Future of Affinity-based Cell Separation Technologies. Acta Biomater 2020; 112:29-51. [PMID: 32442784 PMCID: PMC10364325 DOI: 10.1016/j.actbio.2020.05.004] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 04/29/2020] [Accepted: 05/05/2020] [Indexed: 02/06/2023]
Abstract
Progress in cell purification technology is critical to increase the availability of viable cells for therapeutic, diagnostic, and research applications. A variety of techniques are now available for cell separation, ranging from non-affinity methods such as density gradient centrifugation, dielectrophoresis, and filtration, to affinity methods such as chromatography, two-phase partitioning, and magnetic-/fluorescence-assisted cell sorting. For clinical and analytical procedures that require highly purified cells, the choice of cell purification method is crucial, since every method offers a different balance between yield, purity, and bioactivity of the cell product. For most applications, the requisite purity is only achievable through affinity methods, owing to the high target specificity that they grant. In this review, we discuss past and current methods for developing cell-targeting affinity ligands and their application in cell purification, along with the benefits and challenges associated with different purification formats. We further present new technologies, like stimuli-responsive ligands and parallelized microfluidic devices, towards improving the viability and throughput of cell products for tissue engineering and regenerative medicine. Our comparative analysis provides guidance in the multifarious landscape of cell separation techniques and highlights new technologies that are poised to play a key role in the future of cell purification in clinical settings and the biotech industry. STATEMENT OF SIGNIFICANCE: Technologies for cell purification have served science, medicine, and industrial biotechnology and biomanufacturing for decades. This review presents a comprehensive survey of this field by highlighting the scope and relevance of all known methods for cell isolation, old and new alike. The first section covers the main classes of target cells and compares traditional non-affinity and affinity-based purification techniques, focusing on established ligands and chromatographic formats. The second section presents an excursus of affinity-based pseudo-chromatographic and non-chromatographic technologies, especially focusing on magnetic-activated cell sorting (MACS) and fluorescence-activated cell sorting (FACS). Finally, the third section presents an overview of new technologies and emerging trends, highlighting how the progress in chemical, material, and microfluidic sciences has opened new exciting avenues towards high-throughput and high-purity cell isolation processes. This review is designed to guide scientists and engineers in their choice of suitable cell purification techniques for research or bioprocessing needs.
Collapse
Affiliation(s)
- Kaitlyn Bacon
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695-7905, USA
| | - Ashton Lavoie
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695-7905, USA
| | - Balaji M Rao
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695-7905, USA; Biomanufacturing Training and Education Center (BTEC), North Carolina State University, Raleigh, NC 27695-7928, USA
| | - Michael Daniele
- Joint Department of Biomedical Engineering, North Carolina State University - University of North Carolina Chapel Hill, North Carolina, United States
| | - Stefano Menegatti
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695-7905, USA; Biomanufacturing Training and Education Center (BTEC), North Carolina State University, Raleigh, NC 27695-7928, USA.
| |
Collapse
|
10
|
AbuElela AF, Al-Amoodi AS, Ali AJ, Merzaban JS. Fluorescent Multiplex Cell Rolling Assay: Simultaneous Capturing up to Seven Samples in Real-Time Using Spectral Confocal Microscopy. Anal Chem 2020; 92:6200-6206. [PMID: 32264668 DOI: 10.1021/acs.analchem.9b04549] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The parallel plate flow chamber assay is widely utilized to study physiological cell-cell adhesive interactions under dynamic flow that mimics the bloodstream. In this technique, the cells are perfused under defined shear stresses over a monolayer of endothelial cells (expressing homing molecules, e.g., selectins) or a surface (expressing recombinant homing molecules). However, with the need to study multiple samples and multiple parameters per sample, using a traditional bright-field microscope-based flow assay allows only one sample at a time to be analyzed, resulting in high interexperiment variability, the need for normalization, waste of materials, and significant consumption of time. We developed a multiplexing approach using a three-color fluorescence staining method, which allowed for up to seven different combination signatures to be run at one time. Using this fluorescent multiplex cell rolling (FMCR) assay, each sample is labeled with a different signature of emission wavelengths and mixed with other samples just minutes before the flow run. Subsequently, real-time images are acquired in a single pass using a line-scanning spectral confocal microscope. To illustrate the glycan-dependent binding of E-selectin, a central molecule in cell migration, to its glycosylated ligands expressed on myeloid-leukemic cells in flow, the FMCR assay was used to analyze E-selectin-ligand interactions following the addition (fucosyltransferase-treatment) or removal (deglycosylation) of key glycans on the flowing cells. The FMCR assay allowed us to analyze the cell-adhesion events from these different treatment conditions simultaneously in a competitive manner and to calculate differences in rolling frequency, velocity, and tethering capability of cells under study.
Collapse
Affiliation(s)
- Ayman F AbuElela
- Cell Migration and Signaling Laboratory, King Abdullah University of Science and Technology, Biological and Environmental Sciences and Engineering Division, Thuwal, Saudi Arabia
| | - Asma S Al-Amoodi
- Cell Migration and Signaling Laboratory, King Abdullah University of Science and Technology, Biological and Environmental Sciences and Engineering Division, Thuwal, Saudi Arabia
| | - Amal J Ali
- Cell Migration and Signaling Laboratory, King Abdullah University of Science and Technology, Biological and Environmental Sciences and Engineering Division, Thuwal, Saudi Arabia
| | - Jasmeen S Merzaban
- Cell Migration and Signaling Laboratory, King Abdullah University of Science and Technology, Biological and Environmental Sciences and Engineering Division, Thuwal, Saudi Arabia
| |
Collapse
|
11
|
Connolly S, Newport D, McGourty K. The mechanical responses of advecting cells in confined flow. BIOMICROFLUIDICS 2020; 14:031501. [PMID: 32454924 PMCID: PMC7200165 DOI: 10.1063/5.0005154] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Accepted: 04/21/2020] [Indexed: 05/03/2023]
Abstract
Fluid dynamics have long influenced cells in suspension. Red blood cells and white blood cells are advected through biological microchannels in both the cardiovascular and lymphatic systems and, as a result, are subject to a wide variety of complex fluidic forces as they pass through. In vivo, microfluidic forces influence different biological processes such as the spreading of infection, cancer metastasis, and cell viability, highlighting the importance of fluid dynamics in the blood and lymphatic vessels. This suggests that in vitro devices carrying cell suspensions may influence the viability and functionality of cells. Lab-on-a-chip, flow cytometry, and cell therapies involve cell suspensions flowing through microchannels of approximately 100-800 μ m. This review begins by examining the current fundamental theories and techniques behind the fluidic forces and inertial focusing acting on cells in suspension, before exploring studies that have investigated how these fluidic forces affect the reactions of suspended cells. In light of these studies' findings, both in vivo and in vitro fluidic cell microenvironments shall also be discussed before concluding with recommendations for the field.
Collapse
Affiliation(s)
- S Connolly
- School of Engineering, Bernal Institute, University of Limerick, Limerick V94 T9PX, Ireland
| | - D Newport
- School of Engineering, Bernal Institute, University of Limerick, Limerick V94 T9PX, Ireland
| | | |
Collapse
|
12
|
Khorram A, Vahidi B, Ahmadian B. Computational analysis of adhesion between a cancer cell and a white blood cell in a bifurcated microvessel. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 186:105195. [PMID: 31734471 DOI: 10.1016/j.cmpb.2019.105195] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Revised: 11/03/2019] [Accepted: 11/07/2019] [Indexed: 06/10/2023]
Abstract
BACKGROUND AND OBJECTIVE Cancer is one of the diseases caused by irregular and uncontrolled growth of cells and their propagation into various parts of the body. The motion and adhesion of cancer cells in a blood vessel is a critical step in tumor progression that depends on some vascular parameters such as vessel branching. In this study, effect of microvessel branching on the bonds between a cancer cell and a white blood has been investigated as compared to an analogous problem in a straight vessel. METHODS The analysis is performed using finite elements and fluid-structure interaction methods. Moreover, the equations for adhesion of the cancer cell to white blood cell are coded in MATLAB for calculating forces between them and the code is coupled directly and simultaneously with the COMSOL software. For fluid-structure interaction analysis, it is assumed that the properties of the blood and the cells are homogeneous and the fluid is incompressible and Newtonian. Cancer cell is modeled as a rigid body and white blood cell is assumed as linear elastic. RESULTS The results show that although the geometry of the vessel does not affect on the separation distance of cancer cell considerably, but at the area near a bifurcation, high fluctuations in cancer cell velocity is occurred due to increasing in number of bond formation between the cancer cell and the white blood cell. Accordingly, it can be predicted that higher concentration of adhered particles occurs near the bifurcations. Moreover, shear stress at the point of contact of the cancer cell and the white blood cell in the branched vessel is greater than that in the straight path. In addition to, the probability of breaking of the bond between the cancer cell and the white blood cell increases in the branched vessel. CONCLUSIONS Through consideration in the adhesion charts of this study along with observations from medical interventions such as drug delivery to cancer patients, considerable developments on the treatment or prevention of cancer metastasis may be achieved.
Collapse
Affiliation(s)
- Asghar Khorram
- Division of Biomedical Engineering, Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
| | - Bahman Vahidi
- Division of Biomedical Engineering, Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran.
| | - Bahram Ahmadian
- Division of Biomedical Engineering, Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
| |
Collapse
|
13
|
Aleisa FA, Sakashita K, Lee JM, AbuSamra DB, Al Alwan B, Nozue S, Tehseen M, Hamdan SM, Habuchi S, Kusakabe T, Merzaban JS. Functional binding of E-selectin to its ligands is enhanced by structural features beyond its lectin domain. J Biol Chem 2020; 295:3719-3733. [PMID: 31949047 PMCID: PMC7076219 DOI: 10.1074/jbc.ra119.010910] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Revised: 01/12/2020] [Indexed: 12/19/2022] Open
Abstract
Selectins are key to mediating interactions involved in cellular adhesion and migration, underlying processes such as immune responses, metastasis, and transplantation. Selectins are composed of a lectin domain, an epidermal growth factor (EGF)-like domain, multiple short consensus repeats (SCRs), a transmembrane domain, and a cytoplasmic tail. It is well-established that the lectin and EGF domains are required to mediate interactions with ligands; however, the contributions of the other domains in mediating these interactions remain obscure. Using various E-selectin constructs produced in a newly developed silkworm-based expression system and several assays performed under both static and physiological flow conditions, including flow cytometry, glycan array analysis, surface plasmon resonance, and cell-rolling assays, we show here that a reduction in the number of SCR domains is correlated with a decline in functional E-selectin binding to hematopoietic cell E- and/or L-selectin ligand (HCELL) and P-selectin glycoprotein ligand-1 (PSGL-1). Moreover, the binding was significantly improved through E-selectin dimerization and by a substitution (A28H) that mimics an extended conformation of the lectin and EGF domains. Analyses of the association and dissociation rates indicated that the SCR domains, conformational extension, and dimerization collectively contribute to the association rate of E-selectin-ligand binding, whereas just the lectin and EGF domains contribute to the dissociation rate. These findings provide the first evidence of the critical role of the association rate in functional E-selectin-ligand interactions, and they highlight that the SCR domains have an important role that goes beyond the structural extension of the lectin and EGF domains.
Collapse
Affiliation(s)
- Fajr A Aleisa
- Division of Biological and Environmental Sciences and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia, 23955-6900
| | - Kosuke Sakashita
- Division of Biological and Environmental Sciences and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia, 23955-6900
| | - Jae Man Lee
- Laboratory of Insect Genome Science, Kyushu University Graduate School of Bioresource and Bioenvironmental Sciences, Hakozaki 6-10-1, Higashi-ku, Fukuoka 812-8581, Japan
| | - Dina B AbuSamra
- Division of Biological and Environmental Sciences and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia, 23955-6900
| | - Bader Al Alwan
- Division of Biological and Environmental Sciences and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia, 23955-6900
| | - Shuho Nozue
- Division of Biological and Environmental Sciences and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia, 23955-6900
| | - Muhammad Tehseen
- Division of Biological and Environmental Sciences and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia, 23955-6900
| | - Samir M Hamdan
- Division of Biological and Environmental Sciences and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia, 23955-6900
| | - Satoshi Habuchi
- Division of Biological and Environmental Sciences and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia, 23955-6900
| | - Takahiro Kusakabe
- Laboratory of Insect Genome Science, Kyushu University Graduate School of Bioresource and Bioenvironmental Sciences, Hakozaki 6-10-1, Higashi-ku, Fukuoka 812-8581, Japan
| | - Jasmeen S Merzaban
- Division of Biological and Environmental Sciences and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia, 23955-6900.
| |
Collapse
|
14
|
Li L, Kang W, Wang J. Mechanical Model for Catch-Bond-Mediated Cell Adhesion in Shear Flow. Int J Mol Sci 2020; 21:ijms21020584. [PMID: 31963253 PMCID: PMC7013535 DOI: 10.3390/ijms21020584] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Accepted: 01/13/2020] [Indexed: 12/31/2022] Open
Abstract
Catch bond, whose lifetime increases with applied tensile force, can often mediate rolling adhesion of cells in a hydrodynamic environment. However, the mechanical mechanism governing the kinetics of rolling adhesion of cells through catch-bond under shear flow is not yet clear. In this study, a mechanical model is proposed for catch-bond-mediated cell adhesion in shear flow. The stochastic reaction of bond formation and dissociation is described as a Markovian process, whereas the dynamic motion of cells follows classical analytical mechanics. The steady state of cells significantly depends on the shear rate of flow. The upper and lower critical shear rates required for cell detachment and attachment are extracted, respectively. When the shear rate increases from the lower threshold to the upper threshold, cell rolling became slower and more regular, implying the flow-enhanced adhesion phenomenon. Our results suggest that this flow-enhanced stability of rolling adhesion is attributed to the competition between stochastic reactions of bonds and dynamics of cell rolling, instead of force lengthening the lifetime of catch bonds, thereby challenging the current view in understanding the mechanism behind this flow-enhanced adhesion phenomenon. Moreover, the loading history of flow defining bistability of cell adhesion in shear flow is predicted. These theoretical predictions are verified by Monte Carlo simulations and are related to the experimental observations reported in literature.
Collapse
Affiliation(s)
- Long Li
- Key Laboratory of Mechanics on Disaster and Environment in Western China, Ministry of Education, College of Civil Engineering and Mechanics, Lanzhou University, Lanzhou 730000, China;
- PULS Group, Institute for Theoretical Physics, FAU Erlangen-Nürnberg, 91058 Erlangen, Germany
- Correspondence: (L.L.); (J.W.)
| | - Wei Kang
- Key Laboratory of Mechanics on Disaster and Environment in Western China, Ministry of Education, College of Civil Engineering and Mechanics, Lanzhou University, Lanzhou 730000, China;
| | - Jizeng Wang
- Key Laboratory of Mechanics on Disaster and Environment in Western China, Ministry of Education, College of Civil Engineering and Mechanics, Lanzhou University, Lanzhou 730000, China;
- Correspondence: (L.L.); (J.W.)
| |
Collapse
|
15
|
Mechanics of actin filaments in cancer onset and progress. INTERNATIONAL REVIEW OF CELL AND MOLECULAR BIOLOGY 2020; 355:205-243. [DOI: 10.1016/bs.ircmb.2020.05.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
16
|
Sharifi F, Htwe SS, Righi M, Liu H, Pietralunga A, Yesil-Celiktas O, Maharjan S, Cha BH, Shin SR, Dokmeci MR, Vrana NE, Ghaemmaghami AM, Khademhosseini A, Zhang YS. A Foreign Body Response-on-a-Chip Platform. Adv Healthc Mater 2019; 8:e1801425. [PMID: 30694616 PMCID: PMC6398437 DOI: 10.1002/adhm.201801425] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2018] [Revised: 12/17/2018] [Indexed: 11/10/2022]
Abstract
Understanding the foreign body response (FBR) and desiging strategies to modulate such a response represent a grand challenge for implant devices and biomaterials. Here, the development of a microfluidic platform is reported, i.e., the FBR-on-a-chip (FBROC) for modeling the cascade of events during immune cell response to implants. The platform models the native implant microenvironment where the implants are interfaced directly with surrounding tissues, as well as vasculature with circulating immune cells. The study demonstrates that the release of cytokines such as monocyte chemoattractant protein 1 (MCP-1) from the extracellular matrix (ECM)-like hydrogels in the bottom tissue chamber induces trans-endothelial migration of circulating monocytes in the vascular channel toward the hydrogels, thus mimicking implant-induced inflammation. Data using patient-derived peripheral blood mononuclear cells further reveal inter-patient differences in FBR, highlighting the potential of this platform for monitoring FBR in a personalized manner. The prototype FBROC platform provides an enabling strategy to interrogate FBR on various implants, including biomaterials and engineered tissue constructs, in a physiologically relevant and individual-specific manner.
Collapse
Affiliation(s)
- Fatemeh Sharifi
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA, 02139, USA
- School of Mechanical Engineering, Sharif University of Technology, Tehran, 11155-8639, Iran
| | - Su Su Htwe
- Immunology and Immuno-bioengineering Group, School of Life Science, Faculty of Medicine and Health Sciences, University of Nottingham, Nottingham, NG7 2RD, UK
| | - Martina Righi
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA, 02139, USA
| | - Hua Liu
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA, 02139, USA
| | - Anna Pietralunga
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA, 02139, USA
| | - Ozlem Yesil-Celiktas
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA, 02139, USA
- Department of Bioengineering, Faculty of Engineering Ege University, Bornova, 35100, Izmir, Turkey
| | - Sushila Maharjan
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA, 02139, USA
| | - Byung-Hyun Cha
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA, 02139, USA
| | - Su Ryon Shin
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA, 02139, USA
| | - Mehmet Remzi Dokmeci
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA, 02139, USA
- The BioRobotics Institute, Sant'Anna School of Advanced Studies, Piaggio, 56025, Italy
- Department of Radiology, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, Department of Chemical and Biomolecular Engineering, Henry Samueli School of Engineering and Applied Sciences, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioindustrial Technologies, Konkuk University, Seoul, 05029, Republic of Korea
| | - Nihal Engin Vrana
- Biomatériaux et Bioingénierie, Institut National de la Santé et de la Recherche Médicale (INSERM), 67085, Strasbourg, France
- Protip Medical, 67000, Strasbourg, France
- Fédération de Médecine Translationnelle de Strasbourg, Fédération des Matériaux et Nanoscience d'Alsace (FMNA), Faculté de Chirurgie Dentaire, Université de Strasbourg, 67000, Strasbourg, France
| | - Amir M Ghaemmaghami
- Immunology and Immuno-bioengineering Group, School of Life Science, Faculty of Medicine and Health Sciences, University of Nottingham, Nottingham, NG7 2RD, UK
| | - Ali Khademhosseini
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA, 02139, USA
- The BioRobotics Institute, Sant'Anna School of Advanced Studies, Piaggio, 56025, Italy
- Dr. Li Dak Sum & Yip Yio Chin Center for Stem Cells and Regenerative Medicine, Zhejiang University School of Medicine, Hangzhou, 310012, P. R. China
- Key Laboratory of Tissue Engineering and Regenerative Medicine of Zhejiang Province, Zhejiang University School of Medicine, Hangzhou, 310012, P. R. China
- Research Institute for Bioscience and Biotechnology, Lalitpur, 44600, Nepal
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA, 90095, USA
- Department of Radiology, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, Department of Chemical and Biomolecular Engineering, Henry Samueli School of Engineering and Applied Sciences, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - Yu Shrike Zhang
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA, 02139, USA
| |
Collapse
|
17
|
Ani CJ, Obayemi JD, Uzonwanne VO, Danyuo Y, Odusanya OS, Hu J, Malatesta K, Soboyejo WO. A shear assay study of single normal/breast cancer cell deformation and detachment from poly-di-methyl-siloxane (PDMS) surfaces. J Mech Behav Biomed Mater 2018; 91:76-90. [PMID: 30544025 DOI: 10.1016/j.jmbbm.2018.11.012] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2015] [Revised: 06/25/2018] [Accepted: 11/12/2018] [Indexed: 02/01/2023]
Abstract
This paper presents the results of a combined experimental and analytical/computational study of viscoelastic cell deformation and detachment from poly-di-methyl-siloxane (PDMS) surfaces. Fluid mechanics and fracture mechanics concepts are used to model the detachment of biological cells observed under shear assay conditions. The analytical and computational models are used to compute crack driving forces, which are then related to crack extension during the detachment of normal breast cells and breast cancer cells from PDMS surfaces that are relevant to biomedical implants. The interactions between cells and the extracellular matrix, or the extracellular matrix and the PDMS substrate, are then characterized using force microscopy measurements of the pull-off forces that are used to determine the adhesion energies. Finally, fluorescence microscopy staining of the cytosketelal structures (actin, micro-tubulin and cyto-keratin), transmembrane proteins (vimentin) and the ECM structures (Arginin Glycine Aspartate - RGD) is used to show that the detachment of cells during the shear assay experiments occurs via interfacial cracking between (between the ECM and the cell membranes) with a high incidence of crack bridging by transmembrane vinculin structures that undergo pull-out until they detach from the actin cytoskeletal structure. The implications of the results are discussed for the design of interfaces that are relevant to implantable biomedical devices and normal/cancer tissue.
Collapse
Affiliation(s)
- C J Ani
- Department of Theoretical and Applied Physics, African University of Science and Technology, Km 10, Airport Road, Galadimawa, Abuja, Federal Capital Territory, Nigeria; Department of Physics, Salem University, Km 16, PMB 1060, Lokoja, Kogi State, Nigeria
| | - J D Obayemi
- Department of Mechanical Engineering, Worcester Polytechnic Institute (WPI), Worcester, MA 01609, USA
| | - V O Uzonwanne
- Department of Mechanical Engineering, Worcester Polytechnic Institute (WPI), Worcester, MA 01609, USA
| | - Y Danyuo
- Department of Mechanical Engineering, Ashesi University, Berekuso, Ghana; Department of Materials Science and Engineering, African University of Science and Technology, Km 10, Airport Road, Galadimawa, Abuja, Federal Capital Territory, Nigeria
| | - O S Odusanya
- Advanced Biotechnology Laboratory, Sheda Science and Technology Complex, Abuja, Nigeria
| | - J Hu
- Princeton Institute for the Science and Technology of Materials (PRISM), and The Department of Mechanical and Aerospace Engineering, Princeton University, Princeton, NJ 08544, USA
| | - K Malatesta
- Princeton Institute for the Science and Technology of Materials (PRISM), and The Department of Mechanical and Aerospace Engineering, Princeton University, Princeton, NJ 08544, USA
| | - W O Soboyejo
- Department of Mechanical Engineering, Worcester Polytechnic Institute (WPI), Worcester, MA 01609, USA; Department of Materials Science and Engineering, African University of Science and Technology, Km 10, Airport Road, Galadimawa, Abuja, Federal Capital Territory, Nigeria; Advanced Biotechnology Laboratory, Sheda Science and Technology Complex, Abuja, Nigeria.
| |
Collapse
|
18
|
Shirai A, Sugiyama Y, Rieu JP. Differentiation of neutrophil-like HL-60 cells strongly impacts their rolling on surfaces with various adhesive properties under a pressing force. Technol Health Care 2018; 26:93-108. [PMID: 29309044 DOI: 10.3233/thc-171052] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
BACKGROUND HL-60 cells have been used in in vitro experiments of neutrophils rolling. They lose uniform spherical appearance and enhance deformability by differentiation to neutrophil-like cells, which would affect their rolling characteristics. OBJECTIVE We investigate the influence of differentiation and coating of target substrate on the fundamental rolling characteristics of the cells under a constant pressing force which mimics the pressing force to the vessel wall by erythrocytes in vivo. METHODS Motions of undifferentiated and differentiated HL-60 cells on plain or MPC-polymer-coated flat glass substrate were compared using a homemade inclined centrifuge microscope system. RESULTS Most of the cells alternated between stop and go during the motion. The differentiation resulted in a high temporal ratio of the non-moving state and low mean velocity during the moving state, together with a high suppression performance of cell adhesion by the polymer. It was also suggested that the cells were mostly rolling but that the coating probably induced an infrequent slip on the substrate to stabilize the cells motion. CONCLUSIONS Differentiation strongly affects adhesivity of HL-60 cells but less affects the mean velocity. Our findings also demonstrate the importance of the pressing force and advantage of the present system with respect to classical flow chambers.
Collapse
Affiliation(s)
- Atsushi Shirai
- Institute of Fluid Science, Tohoku University, Sendai, Miyagi, Japan
| | - Yoshiro Sugiyama
- Graduate School of Engineering, Tohoku University, Sendai, Miyagi, Japan
| | - Jean-Paul Rieu
- Univ Lyon, Université Claude Bernard Lyon 1, CNRS, Institut Lumière Matière, F-69622, Villeurbanne, France
| |
Collapse
|
19
|
Esfahani AM, Zhao W, Chen JY, Huang C, Xi N, Xi J, Yang R. On the Measurement of Energy Dissipation of Adhered Cells with the Quartz Microbalance with Dissipation Monitoring. Anal Chem 2018; 90:10340-10349. [PMID: 30088414 PMCID: PMC6669898 DOI: 10.1021/acs.analchem.8b02153] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
We previously reported the finding of a linear correlation between the change of energy dissipation (Δ D) of adhered cells measured with the quartz crystal microbalance with dissipation monitoring (QCM-D) and the level of focal adhesions of the cells. To account for this correlation, we have developed a theoretical framework for assessing the Δ D-response of adhered cells. We rationalized that the mechanical energy of an oscillating QCM-D sensor coupled with a cell monolayer is dissipated through three main processes: the interfacial friction through the dynamic restructuring (formation and rupture) of cell-extracellular matrix (ECM) bonds, the interfacial viscous damping by the liquid trapped between the QCM-D sensor and the basal membrane of the cell layer, and the intracellular viscous damping through the viscous slip between the cytoplasm and stress fibers as well as among stress fibers themselves. Our modeling study shows that the interfacial viscous damping by the trapped liquid is the primary process for energy dissipation during the early stage of the cell adhesion, whereas the dynamic restructuring of cell-ECM bonds becomes more prevalent during the later stage of the cell adhesion. Our modeling study also establishes a positive linear correlation between the Δ D-response and the level of cell adhesion quantified with the number of cell-ECM bonds, which corroborates our previous experimental finding. This correlation with a wide well-defined linear dynamic range provides a much needed theoretical validation of the dissipation monitoring function of the QCM-D as a powerful quantitative analytical tool for cell study.
Collapse
Affiliation(s)
- Amir Monemian Esfahani
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, Lincoln, NE 48824, United States
| | - Weiwei Zhao
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, Lincoln, NE 48824, United States
| | - Jennifer Y. Chen
- Department of Chemistry, Drexel University, Philadelphia, Pennsylvania 19104, United States
| | - Changjin Huang
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA 15213, United States
| | - Ning Xi
- Department of Industrial and Manufacturing Systems Engineering, The University of Hong Kong, HK, China
| | - Jun Xi
- Department of Chemistry, Drexel University, Philadelphia, Pennsylvania 19104, United States
| | - Ruiguo Yang
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, Lincoln, NE 48824, United States
| |
Collapse
|
20
|
Grec B, Maury B, Meunier N, Navoret L. A 1D model of leukocyte adhesion coupling bond dynamics with blood velocity. J Theor Biol 2018; 452:35-46. [DOI: 10.1016/j.jtbi.2018.02.021] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2017] [Revised: 01/31/2018] [Accepted: 02/19/2018] [Indexed: 01/13/2023]
|
21
|
Moshaei MH, Tehrani M, Sarvestani A. On Stability of Specific Adhesion of Particles to Membranes in Simple Shear Flow. J Biomech Eng 2018; 141:2696679. [PMID: 30098158 DOI: 10.1115/1.4041046] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2017] [Indexed: 12/21/2022]
Abstract
Adhesion of carrier particles to the luminal surface of endothelium under hemodynamic flow conditions is critical for successful vascular drug delivery. Endothelial cells line the inner surface of blood vessels. The effect of mechanical behavior of this compliant surface on the adhesion of blood-borne particles is unknown. In this contribution, we use a phase-plane method, first developed by Hammer and Lauffenburger [Biophysical Journal, 52, 475 (1987)], to analyze the stability of specific adhesion of a spherical particle to a compliant interface layer. We construct a phase diagram that predicts the state of particle adhesion, subjected to an incident simple shear flow, in terms of interfacial elasticity, shear rate, binding affinity of cell adhesive molecules, and their surface density. The main conclusion is that the local deformation of the flexible interface inhibits the stable adhesion of the particle. In comparison with adhesion to a rigid substrate, a greater ligand density is required to establish a stable adhesion between a particle and a compliant interface. The results can be used for the rational design of particles in vascular drug delivery.
Collapse
Affiliation(s)
| | - Mohammad Tehrani
- Department of Mechanical Engineering, Ohio University, Athens OH 45701, USA
| | - Alireza Sarvestani
- Department of Mechanical Engineering, Ohio University, Athens OH 45701, USA; Department of Mechanical Engineering, Mercer University, Macon GA 31207, USA
| |
Collapse
|
22
|
Yang R, Broussard JA, Green KJ, Espinosa HD. Techniques to stimulate and interrogate cell-cell adhesion mechanics. EXTREME MECHANICS LETTERS 2018; 20:125-139. [PMID: 30320194 PMCID: PMC6181239 DOI: 10.1016/j.eml.2017.12.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Cell-cell adhesions maintain the mechanical integrity of multicellular tissues and have recently been found to act as mechanotransducers, translating mechanical cues into biochemical signals. Mechanotransduction studies have primarily focused on focal adhesions, sites of cell-substrate attachment. These studies leverage technical advances in devices and systems interfacing with living cells through cell-extracellular matrix adhesions. As reports of aberrant signal transduction originating from mutations in cell-cell adhesion molecules are being increasingly associated with disease states, growing attention is being paid to this intercellular signaling hub. Along with this renewed focus, new requirements arise for the interrogation and stimulation of cell-cell adhesive junctions. This review covers established experimental techniques for stimulation and interrogation of cell-cell adhesion from cell pairs to monolayers.
Collapse
Affiliation(s)
- Ruiguo Yang
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, Lincoln, NE 68588, United States
- Nebraska Center for Integrated Biomolecular Communication, University of Nebraska-Lincoln, Lincoln, NE 68588, United States
| | - Joshua A. Broussard
- Department of Pathology, Northwestern University, Feinberg School of Medicine, Chicago, IL 60611, United States
- Department of Dermatology, Northwestern University, Feinberg School of Medicine, Chicago, IL 60611, United States
| | - Kathleen J. Green
- Department of Pathology, Northwestern University, Feinberg School of Medicine, Chicago, IL 60611, United States
- Department of Dermatology, Northwestern University, Feinberg School of Medicine, Chicago, IL 60611, United States
| | - Horacio D. Espinosa
- Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208, United States
- Theoretical and Applied Mechanics Program, Northwestern University, Evanston, IL 60208, United States
- Institute for Cellular Engineering Technologies, Northwestern University, Evanston, IL 60208, United States
| |
Collapse
|
23
|
Pujos JS, Reyssat M, Le Goff A. Experimental and numerical study of platelets rolling on a von Willebrand factor-coated surface. Med Eng Phys 2018; 55:25-33. [PMID: 29599066 DOI: 10.1016/j.medengphy.2018.03.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Revised: 02/26/2018] [Accepted: 03/13/2018] [Indexed: 11/26/2022]
Abstract
Blood platelets circulate in the blood and adhere to wounded vessels to initiate coagulation and healing. The first step of this process is the capture of flowing platelets by adhesive molecules located at the wounded vessel wall. In this article, we study the transport of fixed blood platelets in a microfluidic channel coated with von Willebrand factor (vWF), a large multimeric protein expressed by endothelial cells in the vicinity of wounds. We measure the number of platelets adsorbed at the channel surface as a function of both time and space. Experimental results are compared with a new transport model. We show that transverse diffusion is an important feature of our model, while the rolling behaviour of the bounded platelets can be neglected.
Collapse
Affiliation(s)
- Justine S Pujos
- ESPCI Paris, PSL Research University, CNRS UMR 7083 Gulliver, 10 rue Vauquelin, 75231 Paris Cedex 05, France
| | - Mathilde Reyssat
- ESPCI Paris, PSL Research University, CNRS UMR 7083 Gulliver, 10 rue Vauquelin, 75231 Paris Cedex 05, France
| | - Anne Le Goff
- ESPCI Paris, PSL Research University, CNRS UMR 7083 Gulliver, 10 rue Vauquelin, 75231 Paris Cedex 05, France; Sorbonne Universités, Université de Technologie de Compiègne, CNRS UMR 7338 Biomécanique et Bioingénierie, Centre de recherche Royallieu, CS 60 319, Compiègne cedex 60 203, France.
| |
Collapse
|
24
|
Abstract
![]()
Hydrodynamic phenomena
are ubiquitous in living organisms and can
be used to manipulate cells or emulate physiological microenvironments
experienced in vivo. Hydrodynamic effects influence multiple cellular
properties and processes, including cell morphology, intracellular
processes, cell–cell signaling cascades and reaction kinetics,
and play an important role at the single-cell, multicellular, and
organ level. Selected hydrodynamic effects can also be leveraged to
control mechanical stresses, analyte transport, as well as local temperature
within cellular microenvironments. With a better understanding of
fluid mechanics at the micrometer-length scale and the advent of microfluidic
technologies, a new generation of experimental tools that provide
control over cellular microenvironments and emulate physiological
conditions with exquisite accuracy is now emerging. Accordingly, we
believe that it is timely to assess the concepts underlying hydrodynamic
control of cellular microenvironments and their applications and provide
some perspective on the future of such tools in in vitro cell-culture
models. Generally, we describe the interplay between living cells,
hydrodynamic stressors, and fluid flow-induced effects imposed on
the cells. This interplay results in a broad range of chemical, biological,
and physical phenomena in and around cells. More specifically, we
describe and formulate the underlying physics of hydrodynamic phenomena
affecting both adhered and suspended cells. Moreover, we provide an
overview of representative studies that leverage hydrodynamic effects
in the context of single-cell studies within microfluidic systems.
Collapse
Affiliation(s)
- Deborah Huber
- IBM Research-Zürich , Säumerstrasse 4, 8803 Rüschlikon, Switzerland.,Institute of Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich , Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Ali Oskooei
- IBM Research-Zürich , Säumerstrasse 4, 8803 Rüschlikon, Switzerland
| | - Xavier Casadevall I Solvas
- Institute of Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich , Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Andrew deMello
- Institute of Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich , Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Govind V Kaigala
- IBM Research-Zürich , Säumerstrasse 4, 8803 Rüschlikon, Switzerland
| |
Collapse
|
25
|
Mohammadalipour A, Burdick MM, Tees DFJ. Deformability of breast cancer cells in correlation with surface markers and cell rolling. FASEB J 2018; 32:1806-1817. [PMID: 29162703 DOI: 10.1096/fj.201700762r] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Although the cancer stem cell (CSC) hypothesis has been around for many years, the reliability of cell-surface markers to classify CSCs has remained debatable. The finding that cancerous cells are significantly more deformable than healthy ones has provided motivation to consider mechanical properties as a possible biomarker for stemness. In this study, using the micropipette aspiration technique, mechanical properties of multiple breast cancer cell lines were investigated and correlated with breast cancer stem cell (BCSC) marker, CD44+/CD24-/ALDH1+. The results indicated that Hs578T and MDA-MB-231 cell lines with CD44+/CD24-/ALDH1+ phenotype were significantly more deformable than the MDA-MB-468 cell line, which did not express the BCSC marker. The BT-20 cell line with intermediate deformability did not express any CD44+/CD24- phenotype, but it expressed aldehyde dehydrogenase-1 activity. In addition, more-deformable cell lines were found to roll with shear-independent velocities on E-selectin-coated substrates in a parallel-plate flow chamber, which might be a mediating factor for firm adhesion of CSCs to endothelium during metastasis. Our results indicate that rheological properties can be considered as a biomechanical marker in addition to, or as a complement of, surface markers to find more-definitive evidence of CSC characteristics within tumors.-Mohammadalipour, A., Burdick, M. M., Tees, D. F. J. Deformability of breast cancer cells in correlation with surface markers and cell rolling.
Collapse
Affiliation(s)
- Amina Mohammadalipour
- Department of Physics and Astronomy, Ohio University, Athens, Ohio, USA; and.,Department of Chemical and Biomolecular Engineering, Ohio University, Athens, Ohio, USA
| | - Monica M Burdick
- Department of Chemical and Biomolecular Engineering, Ohio University, Athens, Ohio, USA
| | - David F J Tees
- Department of Physics and Astronomy, Ohio University, Athens, Ohio, USA; and
| |
Collapse
|
26
|
Aragon-Sanabria V, Kim GB, Dong C. From Cancer Immunoediting to New Strategies in Cancer Immunotherapy: The Roles of Immune Cells and Mechanics in Oncology. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2018; 1092:113-138. [PMID: 30368751 DOI: 10.1007/978-3-319-95294-9_7] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
For the last three decades, the concept of immunoediting has evolved to characterize our increasing understanding of the interactions between cells from the immune system and cancer development. Elucidating the role of immune cells in the progression of cancer has been very challenging due to their dual role; the immune system can either suppress tumor formation by killing cancer cells, or it can also promote tumor growth. Revealing how immune cells are hampered by the tumor microenvironment and how they aid tumor progression has signaled strategies to reverse these effects and control cancer cell growth; this has been the advent of immunotherapy design. More recently, the role of physical forces in the process of immunoediting has been highlighted by multiple studies focusing on understanding how force changes in the stiffness of the extracellular matrix and fluid flow shear stress contribute to tumor development. Using models in vitro that incorporate biomechanical components, it has been shown that these physical aspects are not only important during the formation and growth of primary tumors, but in the metastatic process as well. In this way, we have also gained insight into the interactions occurring within the vascular system, which are highly affected by the dynamics of physical collisions between cells and by shear forces. Here, we review the concept of cancer immunoediting with an emphasis on biomechanics and conclude with a summary on current immunotherapies and potential new strategies.
Collapse
Affiliation(s)
- Virginia Aragon-Sanabria
- Department of Biomedical Engineering, Pennsylvania State University, University Park, State College, PA, USA
| | - Gloria B Kim
- Department of Biomedical Engineering, Pennsylvania State University, University Park, State College, PA, USA
| | - Cheng Dong
- Department of Biomedical Engineering, Pennsylvania State University, University Park, State College, PA, USA.
| |
Collapse
|
27
|
Chiou K, Collins EMS. Why we need mechanics to understand animal regeneration. Dev Biol 2017; 433:155-165. [PMID: 29179947 DOI: 10.1016/j.ydbio.2017.09.021] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2017] [Revised: 08/31/2017] [Accepted: 09/17/2017] [Indexed: 12/19/2022]
Abstract
Mechanical forces are an important contributor to cell fate specification and cell migration during embryonic development in animals. Similarities between embryogenesis and regeneration, particularly with regards to pattern formation and large-scale tissue movements, suggest similarly important roles for physical forces during regeneration. While the influence of the mechanical environment on stem cell differentiation in vitro is being actively exploited in the fields of tissue engineering and regenerative medicine, comparatively little is known about the role of stresses and strains acting during animal regeneration. In this review, we summarize published work on the role of physical principles and mechanical forces in animal regeneration. Novel experimental techniques aimed at addressing the role of mechanics in embryogenesis have greatly enhanced our understanding at scales from the subcellular to the macroscopic - we believe the time is ripe for the field of regeneration to similarly leverage the tools of the mechanobiological research community.
Collapse
Affiliation(s)
- Kevin Chiou
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Eva-Maria S Collins
- Physics Department, UC San Diego, La Jolla, CA 92093, USA; Section of Cell&Developmental Biology, UC San Diego, La Jolla, CA 92093, USA.
| |
Collapse
|
28
|
Zhang Y, Lyons V, Pappas D. Fundamentals of affinity cell separations. Electrophoresis 2017; 39:732-741. [PMID: 28960354 DOI: 10.1002/elps.201700311] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Revised: 09/14/2017] [Accepted: 09/16/2017] [Indexed: 12/17/2022]
Abstract
Cell separations using affinity methods continue to be an enabling science for a wide variety of applications. In this review, we discuss the fundamental aspects of affinity separation, including the competing forces for cell capture and elution, cell-surface interactions, and models for cell adhesion. Factors affecting separation performance such as bond affinity, contact area, and temperature are presented. We also discuss and demonstrate the effects of nonspecific binding on separation performance. Metrics for evaluating cell separations are presented, along with methods of comparing separation techniques for cell isolation using affinity capture.
Collapse
Affiliation(s)
- Ye Zhang
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, USA
| | - Veronica Lyons
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, USA
| | - Dimitri Pappas
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, USA
| |
Collapse
|
29
|
Deformability- and size-based microcapsule sorting. Med Eng Phys 2017; 48:68-74. [DOI: 10.1016/j.medengphy.2017.06.040] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2017] [Revised: 06/20/2017] [Accepted: 06/25/2017] [Indexed: 12/12/2022]
|
30
|
Chen Y, Austin RH, Sturm JC. On-chip cell labelling and washing by capture and release using microfluidic trap arrays. BIOMICROFLUIDICS 2017; 11:054107. [PMID: 29034051 PMCID: PMC5617739 DOI: 10.1063/1.4985771] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Accepted: 09/12/2017] [Indexed: 05/22/2023]
Abstract
Flow cytometry analysis requires a large amount of isolated, labelled, and purified cells for accurate results. To address the demand for a large quantity of cells prepared in a timely manner, we describe a novel microfluidic trap structure array for on-chip cell labelling, such as intracellular and extracellular labelling, and subsequent washing and release of cells. Each device contains [Formula: see text] trap structures, which made the preparation of large numbers of cells [Formula: see text] possible. The structure has a streamlined shape, which minimizes clogging of cells in capture and release steps. The trap structure arrays are built and tested using leukocytes, with different load flow speeds, incubation times, and release flow speeds. ∼85% of cells are captured independent of the input flow speed. The release efficiency depends on the incubation time, with over ∼80% of captured cells released for up to 20 min incubation, and on-chip labelling and washing with STYO13 are demonstrated. Qualitative models are developed as guidance for designing the proposed trap structure and to explain the increased performance over previous approaches.
Collapse
|
31
|
Edwards EE, Oh J, Anilkumar A, Birmingham KG, Thomas SN. P-, but not E- or L-, selectin-mediated rolling adhesion persistence in hemodynamic flow diverges between metastatic and leukocytic cells. Oncotarget 2017; 8:83585-83601. [PMID: 29137366 PMCID: PMC5663538 DOI: 10.18632/oncotarget.18786] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2017] [Accepted: 05/19/2017] [Indexed: 12/20/2022] Open
Abstract
The ability of leukocytic cells to engage selectins via rolling adhesion is critical to inflammation, but selectins are also implicated in mediating metastatic dissemination. Using a microfluidic- and flow-based cell adhesion chromatography experimental and analytical technique, we interrogated the cell-subtype differences in engagement and sustainment of rolling adhesion on P-, E-, and L-selectin-functionalized surfaces in physiological flow. Our results indicate that, particularly at low concentrations of P-selectin, metastatic but not leukocytic cells exhibit reduced rolling adhesion persistence, whereas both cell subtypes exhibited reduced persistence on L-selectin and high persistence on E-selectin, differences not revealed by flow cytometry analysis or reflected in the extent or velocity of rolling adhesion. Conditions under which adhesion persistence was found to be significantly reduced corresponded to those exhibiting the greatest sensitivity to a selectin-antagonist. Our results suggest that potentially therapeutically exploitable differences in metastatic and leukocytic cell subtype interactions with selectins in physiological flow are identifiable through implementation of functional assays of adhesion persistence in hemodynamic flow utilizing this integrated, flow-based cell adhesion chromatography analytical technique.
Collapse
Affiliation(s)
- Erin Elizabeth Edwards
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, USA.,Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Jaeho Oh
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Ananyaveena Anilkumar
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, USA
| | - Katherine Gayle Birmingham
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, Georgia, USA.,George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Susan Napier Thomas
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, USA.,Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, Georgia, USA.,George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA.,Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| |
Collapse
|
32
|
Lin L, Zeng X. Computational study of cell adhesion and rolling in flow channel by meshfree method. Comput Methods Biomech Biomed Engin 2017; 20:832-841. [PMID: 28290214 DOI: 10.1080/10255842.2017.1303051] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Tethering and rolling of circulating leukocytes on the surface of endothelium are critical steps during an inflammatory response. A soft solid cell model was proposed to study monocytes tethering and rolling behaviors on substrate surface in shear flow. The interactions between monocytes and micro-channel surface were modeled by a coarse-grained molecular adhesive potential. The computational model was implemented in a Lagrange-type meshfree Galerkin formulation to investigate the monocyte tethering and rolling process with different flow rates. From the simulation results, it was found that the flow rate has profound effects on the rolling velocity, contact area and effective stress of monocytes. As the flow rate increased, the rolling velocity would increase linearly, whereas the contact area and average effective stress in monocyte showed nonlinear increase.
Collapse
Affiliation(s)
- Liqiang Lin
- a Department of Mechanical Engineering , University of Texas at San Antonio , San Antonio , TX , USA
| | - Xiaowei Zeng
- a Department of Mechanical Engineering , University of Texas at San Antonio , San Antonio , TX , USA
| |
Collapse
|
33
|
Mapping cell surface adhesion by rotation tracking and adhesion footprinting. Sci Rep 2017; 7:44502. [PMID: 28290531 PMCID: PMC5349612 DOI: 10.1038/srep44502] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Accepted: 02/08/2017] [Indexed: 12/22/2022] Open
Abstract
Rolling adhesion, in which cells passively roll along surfaces under shear flow, is a critical process involved in inflammatory responses and cancer metastasis. Surface adhesion properties regulated by adhesion receptors and membrane tethers are critical in understanding cell rolling behavior. Locally, adhesion molecules are distributed at the tips of membrane tethers. However, how functional adhesion properties are globally distributed on the individual cell’s surface is unknown. Here, we developed a label-free technique to determine the spatial distribution of adhesive properties on rolling cell surfaces. Using dark-field imaging and particle tracking, we extract the rotational motion of individual rolling cells. The rotational information allows us to construct an adhesion map along the contact circumference of a single cell. To complement this approach, we also developed a fluorescent adhesion footprint assay to record the molecular adhesion events from cell rolling. Applying the combination of the two methods on human promyelocytic leukemia cells, our results surprisingly reveal that adhesion is non-uniformly distributed in patches on the cell surfaces. Our label-free adhesion mapping methods are applicable to the variety of cell types that undergo rolling adhesion and provide a quantitative picture of cell surface adhesion at the functional and molecular level.
Collapse
|
34
|
Djukelic M, Wixforth A, Westerhausen C. Influence of neighboring adherent cells on laminar flow induced shear stress in vitro-A systematic study. BIOMICROFLUIDICS 2017; 11:024115. [PMID: 28798851 PMCID: PMC5533534 DOI: 10.1063/1.4979295] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Accepted: 03/15/2017] [Indexed: 06/07/2023]
Abstract
Cells experience forces if subjected to laminar flow. These forces, mostly of shear force character, are strongly dependent not only on the applied flow field itself but also on hydrodynamic effects originating from neighboring cells. This particularly becomes important for the interpretation of data from in vitro experiments in flow chambers without confluent cell layers. By employing numerical Finite Element Method simulations of such assemblies of deformable objects under shear flow, we investigate the occurring stress within elastic adherent cells and the influence of neighboring cells on these quantities. For this, we simulate single and multiple adherent cells of different shapes fixed on a solid substrate under laminar flow parallel to the substrate for different velocities. We determine the local stress within the cells close to the cell-substrate-interface and the overall stress of the cells by surface integration over the cell surface. Comparing each measurand in the case of a multiple cell situation with the corresponding one of single cells under identical conditions, we introduce a dimensionless influence factor. The systematic variation of the distance and angle between cells, where the latter is with respect to the flow direction, flow velocity, Young's modulus, cell shape, and cell number, enables us to describe the actual influence on a cell. Overall, we here demonstrate that the cell density is a crucial parameter for all studies on flow induced experiments on adherent cells in vitro.
Collapse
|
35
|
Warning AD, Datta AK. Mechanistic understanding of non-spherical bacterial attachment and deposition on plant surface structures. Chem Eng Sci 2017. [DOI: 10.1016/j.ces.2016.11.030] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
36
|
Knoll J, Dammert WR, Nirschl H. Integration of a microscope into a centrifuge for adhesion force measurement of particles. POWDER TECHNOL 2017. [DOI: 10.1016/j.powtec.2016.09.065] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
37
|
Abstract
In this study, we present a role of arrayed micropillar structures in cell rolling dynamics. Cell rolling on a ligand coated surface as a means of cell separation was demonstrated using a micropillar-integrated microfluidic channel. This approach allows the separation of cells according to characteristic surface properties, regardless of cell size. In these experiments, different moving trajectories of the cells between a ligand-coated micropost structure and a 1% BSA coated micropost structure were observed using sequential images. Based on the analysis of the angle of travel of cells in the trajectory, the average angles of travel on the ligand-coated microposts were 1.5° and -3.1° on a 1% BSA-coated micropost structure. The overall force equivalent applied to a cell can be analyzed to predict the cell rolling dynamics when a cell is detached. These results show that it will be possible to design chip geometry for delicate operations and to separate target cells. Furthermore, we believe that these control techniques based on a ligand coated micropillar surface can be used for enhancing cell rolling-based separation in a faster and more continuous manner.
Collapse
Affiliation(s)
- Kisoo Kim
- Department of Mechanical Engineering, College of Engineering, Kyung Hee University, Republic of Korea.
| | - Junemo Koo
- Department of Mechanical Engineering, College of Engineering, Kyung Hee University, Republic of Korea.
| | - SangJun Moon
- School of Mechanical and Nuclear Engineering, Ulsan National Institute of Science and Technology, Republic of Korea.
| | - Won Gu Lee
- Department of Mechanical Engineering, College of Engineering, Kyung Hee University, Republic of Korea.
| |
Collapse
|
38
|
Moura Rosa P, Gopalakrishnan N, Ibrahim H, Haug M, Halaas Ø. The intercell dynamics of T cells and dendritic cells in a lymph node-on-a-chip flow device. LAB ON A CHIP 2016; 16:3728-40. [PMID: 27560793 DOI: 10.1039/c6lc00702c] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
T cells play a central role in immunity towards cancer and infectious diseases. T cell responses are initiated in the T cell zone of the lymph node (LN), where resident antigen-bearing dendritic cells (DCs) prime and activate antigen-specific T cells passing by. In the present study, we investigated the T cell : DC interaction in a microfluidic device to understand the intercellular dynamics and physiological conditions in the LN. We show random migration of antigen-specific T cells onto the antigen-presenting DC monolayer independent of the flow direction with a mean T cell : DC dwell time of 12.8 min and a mean velocity of 6 μm min(-1). Furthermore, we investigated the antigen specific vs. unspecific attachment and detachment of CD8(+) and CD4(+) T cells to DCs under varying shear stress. In our system, CD4(+) T cells showed long stable contacts with APCs, whereas CD8(+) T cells presented transient interactions with DCs. By varying the shear stress from 0.01 to 100 Dyn cm(-2), it was also evident that there was a much stronger attachment of antigen-specific than unspecific T cells to stationary DCs up to 1-12 Dyn cm(-2). The mechanical force of the cell : cell interaction associated with the pMHC-TCR match under controlled tangential shear force was estimated to be in the range of 0.25-4.8 nN. Finally, upon performing attachment & detachment tests, there was a steady accumulation of antigen specific CD8(+) T cells and CD4(+) T cells on DCs at low shear stresses, which were released at a stress of 12 Dyn cm(-2). This microphysiological model provides new possibilities to recreate a controlled mechanical force threshold of pMHC-TCR binding, allowing the investigation of intercellular signalling of immune synapses and therapeutic targets for immunotherapy.
Collapse
Affiliation(s)
- Patrícia Moura Rosa
- Department of Cancer Research and Molecular Medicine, Norwegian University of Science and Technology, 7489 Trondheim, Norway.
| | | | | | | | | |
Collapse
|
39
|
Luo ZY, Bai BF. State diagram for adhesion dynamics of deformable capsules under shear flow. SOFT MATTER 2016; 12:6918-6925. [PMID: 27492192 DOI: 10.1039/c6sm01697a] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Due to the significance of understanding the underlying mechanisms of cell adhesion in biological processes and cell capture in biomedical applications, we numerically investigate the adhesion dynamics of deformable capsules under shear flow by using a three-dimensional computational fluid dynamic model. This model is based on the coupling of the front tracking-finite element method for elastic mechanics of the capsule membrane and the adhesion kinetics simulation for adhesive interactions between capsules and functionalized surfaces. Using this model, three distinct adhesion dynamic states are predicted, such as detachment, rolling and firm-adhesion. Specifically, the effects of capsule deformability quantified by the capillary number on the transitions of these three dynamic states are investigated by developing an adhesion dynamic state diagram for the first time. At low capillary numbers (e.g. Ca < 0.0075), whole-capsule deformation confers the capsule a flattened bottom in contact with the functionalized surface, which hence promotes the rolling-to-firm-adhesion transition. It is consistent with the observations from previous studies that cell deformation promotes the adhesion of cells lying in the rolling regime. However, it is surprising to find that, at relatively high capillary numbers (e.g. 0.0075 < Ca < 0.0175), the effect of capsule deformability on its adhesion dynamics is far more complex than just promoting adhesion. High deformability of capsules makes their bottom take a concave shape with no adhesion bond formation in the middle. The appearance of this specific capsule shape inhibits the transitions of both rolling-to-firm-adhesion and detachment-to-rolling, and it means that capsule deformation no longer promotes the capsule adhesion. Besides, it is interesting to note that, when the capillary number exceeds a critical value (e.g. Ca = 0.0175), the rolling state no longer appears, since capsules exhibit large deviation from the spherical shape.
Collapse
Affiliation(s)
- Zheng Yuan Luo
- State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an 710049, P. R. China.
| | - Bo Feng Bai
- State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an 710049, P. R. China.
| |
Collapse
|
40
|
Walz JA, Lui I, Wilson DJ, Mace CR. Lateral Microscope Enables the Direct Observation of Cellular Interfaces and Quantification of Changes in Cell Morphology during Adhesion. ACS Biomater Sci Eng 2016; 2:1367-1375. [DOI: 10.1021/acsbiomaterials.6b00301] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Jenna A. Walz
- Department of Chemistry, Tufts University, 62 Talbot
Avenue, Medford, Massachusetts 02155, United States
| | - Irene Lui
- Department of Chemistry, Tufts University, 62 Talbot
Avenue, Medford, Massachusetts 02155, United States
| | - Daniel J. Wilson
- Department of Chemistry, Tufts University, 62 Talbot
Avenue, Medford, Massachusetts 02155, United States
| | - Charles R. Mace
- Department of Chemistry, Tufts University, 62 Talbot
Avenue, Medford, Massachusetts 02155, United States
| |
Collapse
|
41
|
Does enoxaparin interfere with HMGB1 signaling after TBI? A potential mechanism for reduced cerebral edema and neurologic recovery. J Trauma Acute Care Surg 2016; 80:381-7; discussion 387-9. [PMID: 26670109 DOI: 10.1097/ta.0000000000000935] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
BACKGROUND Enoxaparin (ENX) has been shown to reduce cerebral edema and improve neurologic recovery after traumatic brain injury (TBI), through blunting of cerebral leukocyte (LEU) recruitment. High mobility group box 1 (HMGB1) protein may induce inflammation through LEU activation. We hypothesized that ENX after TBI reduces LEU-mediated edema through blockade of HMGB1 signaling. METHODS Twenty-three CD1 mice underwent severe TBI by controlled cortical impact and were randomized to one of four groups receiving either monoclonal antibody against HMGB1 (MAb) or isotype (Iso) and either ENX (1 mg/kg) or normal saline (NS): NS + Iso (n = 5), NS + MAb (n = 6), ENX + Iso (n = 6), ENX + MAb (n = 6). ENX or NS was administered 2, 8, 14, 23 and 32 hours after TBI. MAb or Iso (25 μg) was administered 2 hours after TBI. At 48 hours, cerebral intravital microscopy served to visualize live LEU interacting with endothelium and microvascular fluorescein isothiocyanate-albumin leakage. The Neurological Severity Score (NSS) graded neurologic recovery; wet-to-dry ratios determined cerebral/lung edema. Analysis of variance with Bonferroni correction was used for statistical analyses. RESULTS ENX and MAb similarly reduced in vivo pial LEU rolling without demonstrating additive effect. In vivo albumin leakage was greatest in vehicle-treated animals but decreased by 25% with either MAb or ENX but by 50% when both were combined. Controlled cortical impact-induced cerebral wet-to-dry ratios were reduced by MAb or ENX without additive effect. Postinjury lung water was reduced by ENX but not by MAb. Neurologic recovery at 24 hours and 48 hours was similarly improved with ENX, MAb, or both treatments combined. CONCLUSION Mirroring ENX, HMGB1 signaling blockade reduces LEU recruitment, cerebrovascular permeability, and cerebral edema following TBI. ENX further reduced lung edema indicating a multifaceted effect beyond HMGB1 blockade. Further study is needed to determine how ENX may play a role in blunting HMGB1 signaling in brain injury patients.
Collapse
|
42
|
Suo J, Edwards EE, Anilkumar A, Sulchek T, Giddens DP, Thomas SN. Force and torque on spherical particles in micro-channel flows using computational fluid dynamics. ROYAL SOCIETY OPEN SCIENCE 2016; 3:160298. [PMID: 27493783 PMCID: PMC4968475 DOI: 10.1098/rsos.160298] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2016] [Accepted: 06/29/2016] [Indexed: 05/12/2023]
Abstract
To delineate the influence of hemodynamic force on cell adhesion processes, model in vitro fluidic assays that mimic physiological conditions are commonly employed. Herein, we offer a framework for solution of the three-dimensional Navier-Stokes equations using computational fluid dynamics (CFD) to estimate the forces resulting from fluid flow near a plane acting on a sphere that is either stationary or in free flow, and we compare these results to a widely used theoretical model that assumes Stokes flow with a constant shear rate. We find that while the full three-dimensional solutions using a parabolic velocity profile in CFD simulations yield similar translational velocities to those predicted by the theoretical method, the CFD approach results in approximately 50% larger rotational velocities over the wall shear stress range of 0.1-5.0 dynes cm(-2). This leads to an approximately 25% difference in force and torque calculations between the two methods. When compared with experimental measurements of translational and rotational velocities of microspheres or cells perfused in microfluidic channels, the CFD simulations yield significantly less error. We propose that CFD modelling can provide better estimations of hemodynamic force levels acting on perfused microspheres and cells in flow fields through microfluidic devices used for cell adhesion dynamics analysis.
Collapse
Affiliation(s)
- Jin Suo
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, GA, USA
| | - Erin E. Edwards
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, GA, USA
| | - Ananyaveena Anilkumar
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Todd Sulchek
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, GA, USA
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Don P. Giddens
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, GA, USA
- Daniel Guggenheim School of Aerospace Engineering, Georgia Institute of Technology, Atlanta, GA, USA
- Authors for correspondence: Don P. Giddens e-mail:
| | - Susan N. Thomas
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, GA, USA
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
- Authors for correspondence: Susan N. Thomas e-mail:
| |
Collapse
|
43
|
Marki A, Gutierrez E, Mikulski Z, Groisman A, Ley K. Microfluidics-based side view flow chamber reveals tether-to-sling transition in rolling neutrophils. Sci Rep 2016; 6:28870. [PMID: 27357741 PMCID: PMC4928115 DOI: 10.1038/srep28870] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2016] [Accepted: 06/06/2016] [Indexed: 12/13/2022] Open
Abstract
Neutrophils rolling at high shear stress (above 6 dyn/cm2) form tethers in the rear and slings in the front. Here, we developed a novel photo-lithographically fabricated, silicone(PDMS)-based side-view flow chamber to dynamically visualize tether and sling formation. Fluorescently membrane-labeled mouse neutrophils rolled on P-selectin substrate at 10 dyn/cm2. Most rolling cells formed 5 tethers that were 2–30 μm long. Breaking of a single tether caused a reproducible forward microjump of the cell, showing that the tether was load-bearing. About 15% of all tether-breaking events resulted in slings. The tether-to-sling transition was fast (<100 ms) with no visible material extending above the rolling cell, suggesting a very low bending modulus of the tether. The sling downstream of the rolling cell aligned according to the streamlines before landing on the flow chamber. These new observations explain how slings form from tethers and provide insight into their biomechanical properties.
Collapse
Affiliation(s)
- Alex Marki
- La Jolla Institute for Allergy and Immunology, La Jolla, CA, USA
| | - Edgar Gutierrez
- Department of Physics and University of California San Diego, La Jolla, CA, USA
| | | | - Alex Groisman
- Department of Physics and University of California San Diego, La Jolla, CA, USA
| | - Klaus Ley
- La Jolla Institute for Allergy and Immunology, La Jolla, CA, USA.,Department of Bioengineering, University of California San Diego, La Jolla, CA, USA
| |
Collapse
|
44
|
Ortiz A, Fuchs SY. Anti-metastatic functions of type 1 interferons: Foundation for the adjuvant therapy of cancer. Cytokine 2016; 89:4-11. [PMID: 26822709 DOI: 10.1016/j.cyto.2016.01.010] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Revised: 01/19/2016] [Accepted: 01/20/2016] [Indexed: 01/08/2023]
Abstract
The anti-tumorigenic effects that type 1 interferons (IFN1) elicited in the in vitro studies prompted consideration of IFN1 as a potent candidate for clinical treatment. Though not all patients responded to IFN1, clinical trials have shown that patients with high risk melanoma, a highly refractory solid malignancy, benefit greatly from intermediate IFN1 treatment in regards to relapse-free and distant-metastasis-free survival. The mechanisms by which IFN1 treatment at early stages of disease suppress tumor recurrence or metastatic incidence are not fully understood. Intracellular IFN1 signaling is known to affect cell differentiation, proliferation, and apoptosis. Moreover, recent studies have revealed specific IFN1-regulated genes that may contribute to IFN1-mediated suppression of cancer progression and metastasis. In concert, expression of these different IFN1 stimulated genes may impede numerous mechanisms that mediate metastatic process. Though, IFN1 treatment is still utilized as part of standard care for metastatic melanoma (alone or in combination with other therapies), cancers find the ways to develop insensitivity to IFN1 treatment allowing for unconstrained disease progression. To determine how and when IFN1 treatment would be most efficacious during disease progression, we must understand how IFN1 signaling affects different metastasis steps. Here, we specifically focus on the anti-metastatic role of endogenous IFN1 and parameters that may help to use pharmaceutical IFN1 in the adjuvant treatment to prevent cancer recurrence and metastatic disease.
Collapse
Affiliation(s)
- Angélica Ortiz
- Department of Biomedical Sciences, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.
| | - Serge Y Fuchs
- Department of Biomedical Sciences, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.
| |
Collapse
|
45
|
Spencer A, Spruell C, Nandi S, Wong M, Creixell M, Baker AB. A high-throughput mechanofluidic screening platform for investigating tumor cell adhesion during metastasis. LAB ON A CHIP 2016; 16:142-52. [PMID: 26584160 PMCID: PMC4691538 DOI: 10.1039/c5lc00994d] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
The metastatic spread of cancer is a major barrier to effective and curative therapies for cancer. During metastasis, tumor cells intravasate into the vascular system, survive in the shear forces and immunological environment of the circulation, and then extravasate into secondary tumor sites. Biophysical forces are potent regulators of cancer biology and are key in many of the steps of metastasis. In particular, the adhesion of circulating cells is highly dependent upon competing forces between cell adhesion receptors and the shear stresses due to fluid flow. Conventional in vitro assays for drug development and the mechanistic study of metastasis are often carried out in the absence of fluidic forces and, consequently, are poorly representative of the true biology of metastasis. Here, we present a novel high-throughput approach to studying cell adhesion under flow that uses a multi-well, mechanofluidic flow system to interrogate adhesion of cancer cell to endothelial cells, extracellular matrix and platelets under physiological shear stresses. We use this system to identify pathways and compounds that can potentially be used to inhibit cancer adhesion under flow by screening anti-inflammatory compounds, integrin inhibitors and a kinase inhibitor library. In particular, we identify several small molecule inhibitors of FLT-3 and AKT that are potent inhibitors of cancer cell adhesion to endothelial cells and platelets under flow. In addition, we found that many kinase inhibitors lead to increased adhesion of cancer cells in flow-based but not static assays. This finding suggests that even compounds that reduce cell proliferation might also enhance cancer cell adhesion during metastasis. Overall, our results validate a novel platform for investigating the mechanisms of cell adhesion under biophysical flow conditions and identify several potential inhibitors of cancer cell adhesion during metastasis.
Collapse
Affiliation(s)
- A Spencer
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX, USA.
| | - C Spruell
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX, USA.
| | - S Nandi
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX, USA.
| | - M Wong
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX, USA.
| | - M Creixell
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX, USA.
| | - A B Baker
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX, USA. and Institute for Cellular and Molecular Biology, University of Texas at Austin, Austin, TX, USA
| |
Collapse
|
46
|
Yoon JH, Kim DK, Key J, Lee SW, Lee SY. Adhesion characteristics of nano/micro-sized particles with dual ligands with different interaction distances. RSC Adv 2016. [DOI: 10.1039/c6ra14974j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Dual ligand conjugated particle for targeted delivery. Rotational dislodging force on the ligand–receptor interaction. Optimal receptor and ligand ratio exist.
Collapse
Affiliation(s)
- J. H. Yoon
- Department of Biomedical Engineering
- Yonsei University
- Wonju
- Republic of Korea
| | - D. K. Kim
- Department of Biomedical Engineering
- Yonsei University
- Wonju
- Republic of Korea
| | - J. Key
- Department of Biomedical Engineering
- Yonsei University
- Wonju
- Republic of Korea
| | - S. W. Lee
- Department of Biomedical Engineering
- Yonsei University
- Wonju
- Republic of Korea
| | - S. Y. Lee
- Department of Biomedical Engineering
- Yonsei University
- Wonju
- Republic of Korea
| |
Collapse
|
47
|
Investigating the effects of membrane deformability on artificial capsule adhesion to the functionalized surface. Biomech Model Mechanobiol 2015; 15:1055-68. [DOI: 10.1007/s10237-015-0742-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2015] [Accepted: 10/26/2015] [Indexed: 10/22/2022]
|
48
|
Knoll J, Knott S, Nirschl H. Characterization of the adhesion force between magnetic microscale particles and the influence of surface-bound protein. POWDER TECHNOL 2015. [DOI: 10.1016/j.powtec.2015.05.028] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
49
|
Allenstein U, Mayr SG, Zink M. Contractile cell forces deform macroscopic cantilevers and quantify biomaterial performance. SOFT MATTER 2015; 11:5053-5059. [PMID: 26027952 DOI: 10.1039/c5sm01212k] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Cells require adhesion to survive, proliferate and migrate, as well as for wound healing and many other functions. The strength of contractile cell forces on an underlying surface is a highly relevant quantity to measure the affinity of cells to a rigid surface with and without coating. Here we show with experimental and theoretical studies that these forces create surface stresses that are sufficient to induce measurable bending of macroscopic cantilevers. Since contractile forces are linked to the formation of focal contacts, results give information on adhesion promoting qualities and allow a comparison of very diverse materials. In exemplary studies, in vitro fibroblast adhesion on the magnetic shape memory alloy Fe-Pd and on the l-lysine derived plasma-functionalized polymer PPLL was determined. We show that cells on Fe-Pd are able to induce surface stresses three times as high as on pure titanium cantilevers. A further increase was observed for PPLL, where the contractile forces are four times higher than on the titanium reference. In addition, we performed finite element simulations on the beam bending to back up the calculation of contractile forces from cantilever bending under non-homogenous surface stress. Our findings consolidate the role of contractile forces as a meaningful measure of biomaterial performance.
Collapse
Affiliation(s)
- U Allenstein
- Leibniz Institute of Surface Modification (IOM) e.V., Permoserstr. 15, 04318 Leipzig, Germany.
| | | | | |
Collapse
|
50
|
Rocheleau AD, Sumagin R, Sarelius IH, King MR. Simulation and Analysis of Tethering Behavior of Neutrophils with Pseudopods. PLoS One 2015; 10:e0128378. [PMID: 26091091 PMCID: PMC4474963 DOI: 10.1371/journal.pone.0128378] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2015] [Accepted: 04/29/2015] [Indexed: 11/30/2022] Open
Abstract
P-selectin and P-selectin glycoprotein ligand-1 (PSGL-1) play important roles in mediating the inflammatory cascade. Selectin kinetics, together with neutrophil hydrodynamics, regulate the fundamental adhesion cascade of cell tethering and rolling on the endothelium. The current study uses the Multiscale Adhesive Dynamics computational model to simulate, for the first time, the tethering and rolling behavior of pseudopod-containing neutrophils as mediated by P-selectin/PSGL-1 bonds. This paper looks at the effect of including P-selectin/PSGL-1 adhesion kinetics. The parameters examined included the shear rate, adhesion on-rate, initial neutrophil position, and receptor number sensitivity. The outcomes analyzed included types of adhesive behavior observed, tether rolling distance and time, number of bonds formed during an adhesive event, contact area, and contact time. In contrast to the hydrodynamic model, P-selectin/PSGL-1 binding slows the neutrophil’s translation in the direction of flow and causes the neutrophil to swing around perpendicular to flow. Several behaviors were observed during the simulations, including tethering without firm adhesion, tethering with downstream firm adhesion, and firm adhesion upon first contact with the endothelium. These behaviors were qualitatively consistent with in vivo data of murine neutrophils with pseudopods. In the simulations, increasing shear rate, receptor count, and bond formation rate increased the incidence of firm adhesion upon first contact with the endothelium. Tethering was conserved across a range of physiological shear rates and was resistant to fluctuations in the number of surface PSGL-1 molecules. In simulations where bonding occurred, interaction with the side of the pseudopod, rather than the tip, afforded more surface area and greater contact time with the endothelial wall.
Collapse
Affiliation(s)
- Anne D. Rocheleau
- Department of Biomedical Engineering, Cornell University, Ithaca, New York, United States of America
| | - Ronen Sumagin
- Department of Pathology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, United States of America
| | - Ingrid H. Sarelius
- Department of Pharmacology and Physiology, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Michael R. King
- Department of Biomedical Engineering, Cornell University, Ithaca, New York, United States of America
- * E-mail:
| |
Collapse
|