1
|
Gathungu RM, Kautz R, Kristal BS, Bird SS, Vouros P. The integration of LC-MS and NMR for the analysis of low molecular weight trace analytes in complex matrices. MASS SPECTROMETRY REVIEWS 2020; 39:35-54. [PMID: 30024655 PMCID: PMC6339611 DOI: 10.1002/mas.21575] [Citation(s) in RCA: 61] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2018] [Accepted: 06/28/2018] [Indexed: 05/12/2023]
Abstract
This review discusses the integration of liquid chromatography (LC), mass spectrometry (MS), and nuclear magnetic resonance (NMR) in the comprehensive analysis of small molecules from complex matrices. We first discuss the steps taken toward making the three technologies compatible, so as to create an efficient analytical platform. The development of online LC-MS-NMR, highlighted by successful applications in the profiling of highly concentrated analytes (LODs 10 μg) is discussed next. This is followed by a detailed overview of the alternative approaches that have been developed to overcome the challenges associated with online LC-MS-NMR that primarily stem from the inherently low sensitivity of NMR. These alternative approaches include the use of stop-flow LC-MS-NMR, loop collection of LC peaks, LC-MS-SPE-NMR, and offline NMR. The potential and limitations of all these approaches is discussed in the context of applications in various fields, including metabolomics and natural product discovery.
Collapse
Affiliation(s)
- Rose M. Gathungu
- Department of Medicine, Division of Sleep and Circadian Disorders, Brigham and Women’s Hospital and Department of Medicine, Division of Sleep Medicine, Harvard Medical School, Boston, Massachusetts
- Barnett Institute of Chemical and Biological Analysis and Department of Chemistry and Chemical Biology, Northeastern University, Boston, Massachusetts
| | - Roger Kautz
- Barnett Institute of Chemical and Biological Analysis and Department of Chemistry and Chemical Biology, Northeastern University, Boston, Massachusetts
| | - Bruce S. Kristal
- Department of Medicine, Division of Sleep and Circadian Disorders, Brigham and Women’s Hospital and Department of Medicine, Division of Sleep Medicine, Harvard Medical School, Boston, Massachusetts
| | | | - Paul Vouros
- Barnett Institute of Chemical and Biological Analysis and Department of Chemistry and Chemical Biology, Northeastern University, Boston, Massachusetts
| |
Collapse
|
2
|
Fang Y, Yushmanov PV, Furó I. Assessing 2D electrophoretic mobility spectroscopy (2D MOSY) for analytical applications. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2017; 55:584-588. [PMID: 27930812 PMCID: PMC5434926 DOI: 10.1002/mrc.4558] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Revised: 11/29/2016] [Accepted: 11/30/2016] [Indexed: 06/06/2023]
Abstract
Electrophoretic displacement of charged entity phase modulates the spectrum acquired in electrophoretic NMR experiments, and this modulation can be presented via 2D FT as 2D mobility spectroscopy (MOSY) spectra. We compare in various mixed solutions the chemical selectivity provided by 2D MOSY spectra with that provided by 2D diffusion-ordered spectroscopy (DOSY) spectra and demonstrate, under the conditions explored, a superior performance of the former method. 2D MOSY compares also favourably with closely related LC-NMR methods. The shape of 2D MOSY spectra in complex mixtures is strongly modulated by the pH of the sample, a feature that has potential for areas such as in drug discovery and metabolomics. Copyright © 2016 The Authors. Magnetic Resonance in Chemistry published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- Yuan Fang
- Division of Applied Physical Chemistry, Department of ChemistryKTH Royal Institute of TechnologyTeknikringen 30SE‐10044StockholmSweden
| | | | - István Furó
- Division of Applied Physical Chemistry, Department of ChemistryKTH Royal Institute of TechnologyTeknikringen 30SE‐10044StockholmSweden
| |
Collapse
|
3
|
Spiess HW. 50th Anniversary Perspective: The Importance of NMR Spectroscopy to Macromolecular Science. Macromolecules 2017. [DOI: 10.1021/acs.macromol.6b02736] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
4
|
Fugariu I, Soong R, Lane D, Fey M, Maas W, Vincent F, Beck A, Schmidig D, Treanor B, Simpson AJ. Towards single egg toxicity screening using microcoil NMR. Analyst 2017; 142:4812-4824. [DOI: 10.1039/c7an01339f] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Planar NMR microcoils are evaluated, their application to single eggs is demonstrated, and their potential for studying smaller single cells is discussed.
Collapse
Affiliation(s)
- I. Fugariu
- Dept. of Chemistry and Dept. Phys. Env. Sci
- University of Toronto at Scarborough
- Scarborough
- Canada
| | - R. Soong
- Dept. of Chemistry and Dept. Phys. Env. Sci
- University of Toronto at Scarborough
- Scarborough
- Canada
| | - D. Lane
- Dept. of Chemistry and Dept. Phys. Env. Sci
- University of Toronto at Scarborough
- Scarborough
- Canada
| | - M. Fey
- Bruker Biospin
- Billerica
- USA
| | | | | | - A. Beck
- Bruker Biospin
- 8117 Fällanden
- Switzerland
| | | | - B. Treanor
- Dept. of Biological Science
- University of Toronto at Scarborough
- Scarborough
- Canada
| | - A. J. Simpson
- Dept. of Chemistry and Dept. Phys. Env. Sci
- University of Toronto at Scarborough
- Scarborough
- Canada
| |
Collapse
|
5
|
Analytical advances in pharmaceutical impurity profiling. Eur J Pharm Sci 2016; 87:118-35. [DOI: 10.1016/j.ejps.2015.12.007] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2015] [Revised: 11/14/2015] [Accepted: 12/05/2015] [Indexed: 01/11/2023]
|
6
|
Maggio RM, Calvo NL, Vignaduzzo SE, Kaufman TS. Pharmaceutical impurities and degradation products: uses and applications of NMR techniques. J Pharm Biomed Anal 2014; 101:102-22. [PMID: 24853620 DOI: 10.1016/j.jpba.2014.04.016] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2014] [Revised: 04/11/2014] [Accepted: 04/12/2014] [Indexed: 11/29/2022]
Abstract
Current standards and regulations demand the pharmaceutical industry not only to produce highly pure drug substances, but to achieve a thorough understanding of the impurities accompanying their manufactured drug substances and products. These challenges have become important goals of process chemistry and have steadily stimulated the search of impurities after accelerated or forced degradation procedures. As a result, impurity profiling is one of the most attractive, active and relevant fields of modern pharmaceutical analysis. This activity includes the identification, structural elucidation and quantitative determination of impurities and degradation products in bulk drugs and their pharmaceutical formulations. Nuclear magnetic resonance (NMR) spectroscopy has evolved into an irreplaceable approach for pharmaceutical quality assessment, currently playing a critical role in unequivocal structure identification as well as structural confirmation (qualitative detection), enabling the understanding of the underlying mechanisms of the formation of process and/or degradation impurities. NMR is able to provide qualitative information without the need of standards of the unknown compounds and multiple components can be quantified in a complex sample without previous separation. When coupled to separative techniques, the resulting hyphenated methodologies enhance the analytical power of this spectroscopy to previously unknown levels. As a result, and by enabling the implementation of rational decisions regarding the identity and level of impurities, NMR contributes to the goal of making better and safer medicines. Herein are discussed the applications of NMR spectroscopy and its hyphenated derivate techniques to the study of a wide range pharmaceutical impurities. Details on the advantages and disadvantages of the methodology and well as specific challenges with regards to the different analytical problems are also presented.
Collapse
Affiliation(s)
- Rubén M Maggio
- Instituto de Química Rosario (IQUIR, CONICET-UNR) and Área Análisis de Medicamentos, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Suipacha 531, Rosario S2002LRK, Argentina
| | - Natalia L Calvo
- Instituto de Química Rosario (IQUIR, CONICET-UNR) and Área Análisis de Medicamentos, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Suipacha 531, Rosario S2002LRK, Argentina
| | - Silvana E Vignaduzzo
- Instituto de Química Rosario (IQUIR, CONICET-UNR) and Área Análisis de Medicamentos, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Suipacha 531, Rosario S2002LRK, Argentina
| | - Teodoro S Kaufman
- Instituto de Química Rosario (IQUIR, CONICET-UNR) and Área Análisis de Medicamentos, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Suipacha 531, Rosario S2002LRK, Argentina.
| |
Collapse
|
7
|
Kuehnbaum NL, Britz-McKibbin P. New Advances in Separation Science for Metabolomics: Resolving Chemical Diversity in a Post-Genomic Era. Chem Rev 2013; 113:2437-68. [DOI: 10.1021/cr300484s] [Citation(s) in RCA: 201] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Naomi L. Kuehnbaum
- Department of Chemistry
and Chemical Biology, McMaster University, Hamilton, Canada
| | | |
Collapse
|
8
|
Singh S, Handa T, Narayanam M, Sahu A, Junwal M, Shah RP. A critical review on the use of modern sophisticated hyphenated tools in the characterization of impurities and degradation products. J Pharm Biomed Anal 2012; 69:148-73. [DOI: 10.1016/j.jpba.2012.03.044] [Citation(s) in RCA: 140] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2012] [Revised: 03/21/2012] [Accepted: 03/22/2012] [Indexed: 11/30/2022]
|
9
|
Jones CJ, Larive CK. Microcoil NMR Study of the Interactions between Doxepin, β-Cyclodextrin, and Acetate during Capillary Isotachophoresis. Anal Chem 2012; 84:7099-106. [DOI: 10.1021/ac301401p] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Christopher J. Jones
- Department of Chemistry, University of California, Riverside, California 92521,
United States
| | - Cynthia K. Larive
- Department of Chemistry, University of California, Riverside, California 92521,
United States
| |
Collapse
|
10
|
|
11
|
Diekmann J, Adams KL, Klunder GL, Evans L, Steele P, Vogt C, Herberg JL. Portable Microcoil NMR Detection Coupled to Capillary Electrophoresis. Anal Chem 2011; 83:1328-35. [DOI: 10.1021/ac102389b] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Joana Diekmann
- Department of Analytical Chemistry, Institute of Inorganic Chemistry, Faculty of Natural Sciences, Leibniz University Hanover, Callinstrasse 1, 30167 Hanover, Germany
| | - Kristl L. Adams
- Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, United States
| | - Gregory L. Klunder
- Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, United States
| | - Lee Evans
- Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, United States
| | - Paul Steele
- Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, United States
| | - Carla Vogt
- Department of Analytical Chemistry, Institute of Inorganic Chemistry, Faculty of Natural Sciences, Leibniz University Hanover, Callinstrasse 1, 30167 Hanover, Germany
| | - Julie L. Herberg
- Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, United States
| |
Collapse
|
12
|
Jones CJ, Beni S, Limtiaco JFK, Langeslay DJ, Larive CK. Heparin characterization: challenges and solutions. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2011; 4:439-465. [PMID: 21469955 DOI: 10.1146/annurev-anchem-061010-113911] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Although heparin is an important and widely prescribed pharmaceutical anticoagulant, its high degree of sequence microheterogeneity and size polydispersity make molecular-level characterization challenging. Unlike nucleic acids and proteins that are biosynthesized through template-driven assembly processes, heparin and the related glycosaminoglycan heparan sulfate are actively remodeled during biosynthesis through a series of enzymatic reactions that lead to variable levels of O- and N-sulfonation and uronic acid epimers. As summarized in this review, heparin sequence information is determined through a bottom-up approach that relies on depolymerization reactions, size- and charge-based separations, and sensitive mass spectrometric and nuclear magnetic resonance experiments to determine the structural identity of component oligosaccharides. The structure-elucidation process, along with its challenges and opportunities for future analytical improvements, is reviewed and illustrated for a heparin-derived hexasaccharide.
Collapse
Affiliation(s)
- Christopher J Jones
- Department of Chemistry, University of California, Riverside, California 92521, USA.
| | | | | | | | | |
Collapse
|
13
|
Felhofer JL, Blanes L, Garcia CD. Recent developments in instrumentation for capillary electrophoresis and microchip-capillary electrophoresis. Electrophoresis 2010; 31:2469-86. [PMID: 20665910 PMCID: PMC2928674 DOI: 10.1002/elps.201000203] [Citation(s) in RCA: 67] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Over the last years, there has been an explosion in the number of developments and applications of CE and microchip-CE. In part, this growth has been the direct consequence of recent developments in instrumentation associated with CE. This review, which is focused on the contributions published in the last 5 years, is intended to complement the articles presented in this special issue dedicated to instrumentation and to provide an overview of the general trends and some of the most remarkable developments published in the areas of high-voltage power supplies, detectors, auxiliary components, and compact systems. It also includes a few examples of alternative uses of and modifications to traditional CE instruments.
Collapse
Affiliation(s)
- Jessica L. Felhofer
- Department of Chemistry, The University of Texas at San Antonio, One UTSA Circle, San Antonio, TX 78249, United States of America
| | - Lucas Blanes
- Centre for Forensic Science, University of Technology, Sydney, PO Box 123, Broadway, NSW 2007, Australia
| | - Carlos D. Garcia
- Department of Chemistry, The University of Texas at San Antonio, One UTSA Circle, San Antonio, TX 78249, United States of America
| |
Collapse
|
14
|
Lin Z, Pang J, Huang H, Zhang L, Chen G. [Recent advances in capillary electrochromatography and its coupling techniques]. Se Pu 2010; 28:273-83. [PMID: 20549979 DOI: 10.3724/sp.j.1123.2010.00273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
As a novel micro-separation technique, capillary electrochromatography (CEC) has the merits of high efficiency, high selectivity, high resolution and rapid analysis. However, the small-volume injection manipulated in capillary dimensions poses a great challenge for detectors in achieving high sensitivity. Currently, one of the major researches into CEC involves the development of some sensitive detection modes. The general introduction, which includes the historical perspectives and the principles of CEC, is briefly described. The recent advances about CEC coupled with various detectors and its applications in the separation of complex samples are summarized. A total of 141 references are reviewed.
Collapse
Affiliation(s)
- Zian Lin
- Key Laboratory of Analysis and Detection Technology for Food Safety of Ministry of Education, College of Chemistry & Chemical Engineering, Fuzhou University, Fuzhou 350002, China.
| | | | | | | | | |
Collapse
|
15
|
|
16
|
Lin Y, Schiavo S, Orjala J, Vouros P, Kautz R. Microscale LC-MS-NMR platform applied to the identification of active cyanobacterial metabolites. Anal Chem 2008; 80:8045-54. [PMID: 18834150 PMCID: PMC2709599 DOI: 10.1021/ac801049k] [Citation(s) in RCA: 93] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
An LC-MS-NMR platform is demonstrated, which combines two innovations in microscale analysis, nanoSplitter LC-MS and microdroplet NMR, for the identification of unknown compounds found at low concentrations in complex sample matrixes as frequently encountered in metabolomics or natural products discovery. The nanoSplitter provides the high sensitivity of nanoelectrospray MS while allowing 98% of the HPLC effluent from a large-bore LC column to be collected and concentrated for NMR. Microdroplet NMR is a droplet microfluidic NMR loading method providing severalfold higher sample efficiency than conventional flow injection methods. Performing NMR offline from LC-UV-MS accommodates the disparity between MS and NMR in their sample mass and time requirements, as well as allowing NMR spectra to be requested retrospectively, after review of the LC-MS data. Interpretable 1D NMR spectra were obtained from analytes at the 200-ng level, in 1 h/well automated NMR data acquisitions. The system also showed excellent intra- and interdetector reproducibility with retention time RSD values less than 2% and sample recovery on the order of 93%. When applied to a cyanobacterial extract showing antibacterial activity, the platform recognized several previously known metabolites, down to the 1% level, in a single 30-mug injection, and prioritized one unknown for further study.
Collapse
Affiliation(s)
| | | | | | | | - Roger Kautz
- To whom correspondence should be addressed. Phone: 617−373−8211. Fax: 617−373−2855. E-mail:
| |
Collapse
|
17
|
Xiong B, Wang W, Miao X, Zhou X, Deng Y, Zhou P, Hu J. Simultaneous LIF and retro-reflected beam interference detection for CE. Electrophoresis 2008; 29:4482-6. [DOI: 10.1002/elps.200800292] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
18
|
Analysis of proteins in solution using affinity capillary electrophoresis. METHODS IN MOLECULAR BIOLOGY (CLIFTON, N.J.) 2008. [PMID: 18826064 DOI: 10.1007/978-1-59745-582-4_21] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register]
Abstract
Analysis of protein interactions by means of capillary electrophoresis (CE) has unique challenges and rewards. The choice of analysis conditions, especially involving electrophoresis buffers, are crucial and not universal for protein analysis. If conditions for analysis can be worked out, it is possible to utilize CE quantitatively and qualitatively to characterize protein-ligand binding involving unmodified molecules in solution and taking place under physiological conditions. This chapter deals with the most important practical considerations in capillary electrophoretic affinity approaches, affinity CE (ACE). The text emphasizes the most critical factors for successful analyses and has application examples illustrating various types of information offered by ACE-based studies. Also included are step-by-step accounts of the two main classes of experimental design: the pre-equilibration ACE (in the form of CE-frontal analysis (CE-FA)) and mobility shift ACE together with examples of their use. The ACE approaches for binding assays of proteins should be considered when the biological material is scarce, when any kind of labeling is not possible or desired, when the interacting molecules are the same size and when rapid and simple method development is a priority.
Collapse
|
19
|
Xiong B, Miao X, Zhou X, Deng Y, Zhou P, Hu J. Simultaneous coaxial thermal lens spectroscopy and retro-reflected beam interference detection for capillary electrophoresis. J Chromatogr A 2008; 1209:260-6. [PMID: 18829035 DOI: 10.1016/j.chroma.2008.09.042] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2008] [Revised: 08/31/2008] [Accepted: 09/03/2008] [Indexed: 10/21/2022]
Abstract
A novel optical scheme, which accomplished simultaneous coaxial thermal lens spectroscopy and retro-reflected beam interference detection for capillary electrophoresis, has been described. By a special design, an adjustable pump laser waist relative to the probe laser waist was implemented, while some key elements for both detection modes were optimized. In either detection modes, certain preponderance compared with former reports was indicated. With both coaxial thermal lens spectroscopy and retro-reflected beam interference detection, the reported detection scheme combined high sensitivity and universal property for capillary electrophoresis detection.
Collapse
Affiliation(s)
- Bo Xiong
- College of Chemistry and Molecular Sciences, Wuhan University, Luojiashan Road 16th, Wuchang District, Wuhan 430072, China
| | | | | | | | | | | |
Collapse
|
20
|
Kentgens APM, Bart J, van Bentum PJM, Brinkmann A, van Eck ERH, Gardeniers JGE, Janssen JWG, Knijn P, Vasa S, Verkuijlen MHW. High-resolution liquid- and solid-state nuclear magnetic resonance of nanoliter sample volumes using microcoil detectors. J Chem Phys 2008; 128:052202. [DOI: 10.1063/1.2833560] [Citation(s) in RCA: 117] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
|
21
|
Lambert M, Wolfender JL, Staerk D, Christensen SB, Hostettmann K, Jaroszewski JW. Identification of natural products using HPLC-SPE combined with CapNMR. Anal Chem 2007; 79:727-35. [PMID: 17222043 DOI: 10.1021/ac0616963] [Citation(s) in RCA: 80] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Two major development areas in HPLC-NMR hyphenation are postcolumn solid-phase extraction (HPLC-SPE-NMR) and capillary separations with NMR detection by means of solenoidal microcoils (CapNMR). These two techniques were combined off-line into HPLC-SPE-CapNMR, which combines the advantage of high loadability of normal-bore HPLC columns with high mass sensitivity of capillary NMR probes with an active volume of 1.5 microL. The technique was used for rapid identification of complex sesquiterpene lactones and esterified phenylpropanoids present in an essentially crude plant extract (toluene fraction of an ethanolic extract of Thapsia garganica fruits). Elution profiles of 10 x 1 mm i.d. SPE cartridges filled with poly(divinylbenzene) resin were found to be only marginally broader than those observed upon direct injection of 6-microL samples into the probe. Thus, the technique focuses analytes emerging in the HPLC elution bands of 0.5-1 mL into volumes of approximately 10 microL, compatible with the CapNMR probe. Using this technique, nine natural products (1-9) present in the plant extract in amounts varying from 0.1 to 20% were identified by means of 1D and 2D NMR spectra, supported by parallel HPLC-ESIMS measurements. Therefore, HPLC-SPE-CapNMR should be regarded as an attractive alternative to other applications of CapNMR for mixture analysis.
Collapse
Affiliation(s)
- Maja Lambert
- Department of Medicinal Chemistry, The Danish University of Pharmaceutical Sciences, Universitetsparken 2, DK-2100 Copenhagen, Denmark
| | | | | | | | | | | |
Collapse
|
22
|
Cruces-Blanco C, Gámiz–Gracia L, García-Campaña A. Applications of capillary electrophoresis in forensic analytical chemistry. Trends Analyt Chem 2007. [DOI: 10.1016/j.trac.2006.12.007] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
|
23
|
Grynbaum MD, Kreidler D, Rehbein J, Purea A, Schuler P, Schaal W, Czesla H, Webb A, Schurig V, Albert K. Hyphenation of Gas Chromatography to Microcoil 1H Nuclear Magnetic Resonance Spectroscopy. Anal Chem 2007; 79:2708-13. [PMID: 17319646 DOI: 10.1021/ac0617767] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Whereas the hyphenation of gas chromatography (GC) with mass spectrometry is of great importance, little is known about the coupling to nuclear magnetic resonance spectroscopy (NMR). The investigation of this technique is an attractive proposition because of the valuable information given by NMR on molecular structure. The experiments shown here are to our knowledge the first hyphenating capillary GC to microcoil NMR. In contrast to liquids, gases have rarely been investigated by NMR, mainly due to the experimental difficulties in handling gases and the low signal-to-noise-ratio (SNR) of the NMR signal obtained at atmospheric pressure. With advances in NMR sensitivity (higher magnetic fields and solenoidal microprobes), this limitation can be largely overcome. In this paper, we describe the use of a custom-built solenoidal NMR microprobe with an active volume of 2 microL for the NMR detection of several compounds at 400 MHz, first in a mixture, and then with full coupling to capillary GC to identify them separately. The injected amounts of each analyte in the hyphenated experiments are in the range of 15-50 micromol, resulting in reasonable SNR for sample masses of 1-2 microg.
Collapse
Affiliation(s)
- Marc David Grynbaum
- Institute of Organic Chemistry, Chemisches Zentral-Institut, University of Tübingen, Auf der Morgenstelle 18, 72076 Tuebingen, Germany
| | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Natishan TK. Recent Progress in the Analysis of Pharmaceuticals by Capillary Electrophoresis. J LIQ CHROMATOGR R T 2007. [DOI: 10.1081/jlc-200053014] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- Theresa K. Natishan
- a Merck & Co., Inc. , Merck Research Laboratories, Analytical Research , Rahway, New Jersey, USA
| |
Collapse
|
25
|
Schroeder FC, Gronquist M. Extending the scope of NMR spectroscopy with microcoil probes. Angew Chem Int Ed Engl 2007; 45:7122-31. [PMID: 16991159 DOI: 10.1002/anie.200601789] [Citation(s) in RCA: 85] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Capillary NMR (CapNMR) spectroscopy has emerged as a major breakthrough for increasing the mass-sensitivity of NMR spectroscopic analysis and enabling the combination of NMR spectroscopy with other analytical techniques. Not only is the acquisition of high-sensitivity spectra getting easier but the quality of CapNMR spectra obtained in many small-molecule applications exceeds what can be accomplished with conventional designs. This Minireview discusses current CapNMR technology and its applications for the characterization of mass-limited, small-molecule and protein samples, the rapid screening of small-molecule or protein libraries, as well as hyphenated techniques that combine CapNMR with other analytical methods.
Collapse
Affiliation(s)
- Frank C Schroeder
- Biological Chemistry and Molecular Pharmacology, Harvard Medical School, 250 Longwood Avenue, Boston, MA 02115, USA.
| | | |
Collapse
|
26
|
Abstract
ITP has been attracting constant attention for many years due to its principal capability to concentrate trace analytes by several orders of magnitude. In the current capillary format, it is able to concentrate trace analytes diluted to several microliters of an original sample into concentrated zones having volumes in the range of picoliters. Due to this reason, ITP holds an important position in many current multistage and multidimensional separation schemes. This article links up previous reviews on the topic and summarizes the progress of analytical capillary ITP since 2002. Almost 100 papers are reviewed that include methodological novelties, instrumental aspects, and analytical applications. Papers using ITP and/or isotachophoretic principles as part of multistage and/or multidimensional separation schemes are also included.
Collapse
Affiliation(s)
- Petr Gebauer
- Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Brno, Czech Republic
| | | | | |
Collapse
|
27
|
Petr J, Maier V, Horáková J, Sevcík J, Stránský Z. Capillary isotachophoresis from the student point of view – images and the reality. J Sep Sci 2006; 29:2705-15. [PMID: 17305231 DOI: 10.1002/jssc.200600249] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A review of some fundamental aspects of ITP from the student point of view, imaginations of some basic facts and laws, use of ITP, and the recent trends are presented. The results of theoretical computations of ITP separation processes are added for comparison of imaginations with the exact mathematical description.
Collapse
Affiliation(s)
- Jan Petr
- Department of Analytical Chemistrý, Palackỳ University, Trída Svobody 8, Olomouc, Czech Republic.
| | | | | | | | | |
Collapse
|
28
|
Schroeder FC, Gronquist M. Größere Möglichkeiten für die NMR-Spektroskopie durch Mikrospulenprobenköpfe. Angew Chem Int Ed Engl 2006. [DOI: 10.1002/ange.200601789] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
29
|
Djukovic D, Liu S, Henry I, Tobias B, Raftery D. Signal enhancement in HPLC/microcoil NMR using automated column trapping. Anal Chem 2006; 78:7154-60. [PMID: 17037915 PMCID: PMC2577147 DOI: 10.1021/ac0605748] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
A new HPLC NMR system is described that performs analytical separation, preconcentration, and NMR spectroscopy in rapid succession. The central component of our method is the online preconcentration sequence that improves the match between postcolumn analyte peak volume and microcoil NMR detection volume. Separated samples are collected on to a C18 guard column with a mobile phase composed of 90% D2O/10% acetonitrile-D3 and back-flushed to the NMR microcoil probe with 90% acetonitrile-D3/10% D2O. To assess the performance of our unit, we separated a standard mixture of 1 mM ibuprofen, naproxen, and phenylbutazone using a commercially available C18 analytical column. The S/N measurements from the NMR acquisitions indicated that we achieved signal enhancement factors up to 10.4 (+/-1.2)-fold. Furthermore, we observed that preconcentration factors increased as the injected amount of analyte decreased. The highest concentration enrichment of 14.7 (+/-2.2)-fold was attained injecting 100 microL of solution of 0.2 mM (approximately 4 microg) ibuprofen.
Collapse
Affiliation(s)
- Danijel Djukovic
- Department of Chemistry, Purdue University 560 Oval Drive, West Lafayette, IN 47907
| | - Shuhui Liu
- Department of Chemistry, Purdue University 560 Oval Drive, West Lafayette, IN 47907
| | - Ian Henry
- Department of Chemistry, Purdue University 560 Oval Drive, West Lafayette, IN 47907
| | | | - Daniel Raftery
- Department of Chemistry, Purdue University 560 Oval Drive, West Lafayette, IN 47907
| |
Collapse
|
30
|
|
31
|
Hentschel P, Grynbaum MD, Molnár P, Putzbach K, Rehbein J, Deli J, Albert K. Structure elucidation of deoxylutein II isomers by on-line capillary high performance liquid chromatography–1H nuclear magnetic resonance spectroscopy. J Chromatogr A 2006; 1112:285-92. [PMID: 16460746 DOI: 10.1016/j.chroma.2005.12.082] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2005] [Revised: 11/21/2005] [Accepted: 12/20/2005] [Indexed: 12/01/2022]
Abstract
Thermal and iodine-catalyzed photochemical (Z/E)-isomerization of deoxylutein II [(3R,6'R)-3-hydroxy-3',4'-didehydro-beta,gamma-carotene, anhydrolutein I] (2), the dehydration product of lutein [(3R,3'R,6'R)-beta,epsilon-carotene-3,3'-diol] (4), yielded multi-component mixtures of (Z)-isomers. By I(2)-catalyzed photoisomerization, (9Z)-2, (9'Z)-2, (13Z)-2, (13'Z)-2 and (15Z)-2 are generated as main products. In addition, this thermodynamic-equilibrium mixture contains traces of (9Z,9'Z)-2 and other (di-Z)-isomers in minor concentrations. Thirteen isomers are chromatographically separated and detected on-line by UV-vis and mass spectrometry. (all-E)-Deoxylutein II (2) and six of its (Z)-configured isomers are separated by capillary HPLC (acetone-d(6)/D(2)O = 85:15) and detected on-line by (1)H NMR spectroscopy in a microprobe. With the microprobe and the active detection volume of 1.5 microl, it is possible to perform structure elucidation with very small amounts available for various (Z)-isomers of deoxylutein II (2) in the isomerization mixture.
Collapse
Affiliation(s)
- Petra Hentschel
- Institute of Organic Chemistry, University of Tübingen, Auf der Morgenstelle 18, D-72076 Tübingen, Germany
| | | | | | | | | | | | | |
Collapse
|
32
|
Kasicka V. Recent developments in capillary electrophoresis and capillary electrochromatography of peptides. Electrophoresis 2006; 27:142-75. [PMID: 16307429 DOI: 10.1002/elps.200500527] [Citation(s) in RCA: 133] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The article gives a comprehensive review on the recent developments in the applications of high-performance capillary electromigration methods, zone electrophoresis, isotachophoresis, isoelectric focusing, affinity electrophoresis, electrokinetic chromatography, and electrochromatography, to analysis, preparation, and physicochemical characterization of peptides. The article presents new approaches to the theoretical description and experimental verification of electromigration behavior of peptides, covers the methodological aspects of capillary electroseparations of peptides, such as rational selection of separation conditions, sample preparation, suppression of peptide adsorption, new developments in individual separation modes, and new designs of detection systems. Several types of applications of capillary electromigration methods to peptide analysis are presented: conventional qualitative and quantitative analysis, purity control, determination in biomatrices, monitoring of chemical and enzymatical reactions and physical changes, amino acid and sequence analysis, and peptide mapping of proteins. Some examples of micropreparative peptide separations are given and capabilities of capillary electromigration techniques to provide important physicochemical characteristics of peptides are demonstrated.
Collapse
Affiliation(s)
- Václav Kasicka
- Institute of Organic Chemistry and Biochemistry, Academy of Sciences of the Czech Republic, Prague, Czech Republic.
| |
Collapse
|
33
|
Bieri S, Varesio E, Veuthey JL, Muñoz O, Tseng LH, Braumann U, Spraul M, Christen P. Identification of isomeric tropane alkaloids from Schizanthus grahamii by HPLC-NMR with loop storage and HPLC-UV-MS/SPE-NMR using a cryogenic flow probe. PHYTOCHEMICAL ANALYSIS : PCA 2006; 17:78-86. [PMID: 16634283 DOI: 10.1002/pca.889] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Two fully automated HPLC-NMR methods are reported and compared for the structure elucidation of four isomeric tropane alkaloids from the stem-bark of an endemic Chilean plant, Schizanthus grahamii Gill. (Solanaceae). The first approach interfaced a conventional HPLC column to NMR by means of a loop storage unit. After elution with a mobile phase consisting of deuterated water and standard protonated organic solvents, the separated analytes were momentarily stored in a loop cassette and then transferred one-at-a-time to the NMR flow probe for measurements. The second strategy combined HPLC with parallel ion-trap MS detection and NMR spectroscopy using an integrated solid-phase extraction (SPE) unit for post-column analyte trapping. The SPE cartridges were dried under a gentle stream of nitrogen and analytes were sequentially eluted and directed to a cryogenically cooled flow-probe with an NMR-friendly solvent. The structures of the four isomeric alkaloids, 3alpha-senecioyloxy-7beta-hydroxytropane, 3alpha-hydroxy-7beta-angeloyloxytropane, 3alpha-hydroxy-7beta-tigloyloxytropane and 3alpha-hydroxy-7beta-senecioyloxytropane, were unambiguously determined by combining NMR assignments with MS data.
Collapse
Affiliation(s)
- Stefan Bieri
- Laboratory of Pharmaceutical Analytical Chemistry, School of Pharmaceutical Sciences EPGL, University of Geneva, 20 Bd d'Yvoy, 1211 Geneva 4, Switzerland
| | | | | | | | | | | | | | | |
Collapse
|
34
|
Cifuentes A. Recent advances in the application of capillary electromigration methods for food analysis. Electrophoresis 2006; 27:283-303. [PMID: 16307427 DOI: 10.1002/elps.200500474] [Citation(s) in RCA: 117] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
This article reviews the latest developments in the application of capillary electromigration methods for the analysis of foods and food components. Nowadays, methods based on CE techniques are becoming widely used in food analytical and research laboratories. This review covers the application of CE to analyze amino acids, biogenic amines, peptides, proteins, DNAs, carbohydrates, phenols, polyphenols, pigments, toxins, pesticides, vitamins, additives, small organic and inorganic ions, chiral compounds, and other compounds in foods, as well as to investigate food interactions and food processing. The use of microchips as well as other foreseen trends in CE analysis of foods is discussed. Papers that were published during the period June 2002-June 2005 are included following the previous review by Frazier and Papadopoulou (Electrophoresis 2003, 24, 4095-4105).
Collapse
Affiliation(s)
- Alejandro Cifuentes
- Department of Food Analysis, Institute of Industrial Fermentations (CSIC), Madrid, Spain.
| |
Collapse
|
35
|
Webb AG. Nuclear magnetic resonance coupled microseparations. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2005; 43:688-96. [PMID: 16049953 DOI: 10.1002/mrc.1616] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
The increased separation efficiency afforded by reducing the size of the separation column has resulted in 'microseparations' becoming an important component in many chemical and biochemical applications. The coupling of microseparations with NMR detection is an area of increasing interest owing to the high structural information of NMR. In order to couple efficiently with the separation, the NMR detector must be reduced in size to correspond to that of the separation peak. This paper summarizes some of the approaches used in coupling NMR detection with pressure-driven and electrophoretic microseparations, the design of small NMR detectors and applications of this technology.
Collapse
Affiliation(s)
- A G Webb
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 61801, USA.
| |
Collapse
|
36
|
Exarchou V, Krucker M, van Beek TA, Vervoort J, Gerothanassis IP, Albert K. LC-NMR coupling technology: recent advancements and applications in natural products analysis. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2005; 43:681-7. [PMID: 16049952 DOI: 10.1002/mrc.1632] [Citation(s) in RCA: 90] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
An overview of recent advances in nuclear magnetic resonance (NMR) coupled with separation technologies and their application in natural product analysis is given and discussed. The different modes of LC-NMR operation are described, as well as how technical improvements assist in establishing LC-NMR as an important tool in the analysis of plant-derived compounds. On-flow, stopped-flow and loop-storage procedures are mentioned, together with the new LC-SPE-NMR configuration. The implementation of mass spectrometry in LC-NMR is also useful on account of the molecular weight and fragmentation information that it provides, especially when new plant species are studied. Cryogenic technology and capillary LC-NMR are the other important recent developments. Since the plant kingdom is endless in producing potential drug candidates, development and optimization of LC-NMR techniques convert the study of natural products to a less-time-consuming task, speeding up identification.
Collapse
|
37
|
Hentschel P, Krucker M, Grynbaum MD, Putzbach K, Bischoff R, Albert K. Determination of regulatory phosphorylation sites in nanogram amounts of a synthetic fragment of ZAP-70 using microprobe NMR and on-line coupled capillary HPLC-NMR. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2005; 43:747-54. [PMID: 16049944 DOI: 10.1002/mrc.1628] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
The protein kinase ZAP-70 is involved in T-cell activation and interacts with tyrosine-phosphorylated peptide sequences known as immunoreceptor tyrosine activation motifs (ITAMs). We have studied the regulatory phosphorylation sites in the tryptic fragment containing amino acids 485-496 (ALGADDSYYTAR). The four possible peptides with phosphorylation at none, one, or both of the Y-492 and Y-493 tyrosines were specifically synthesized and analyzed by (1)H/(13)C-NMR at 600 MHz using a capillary HPLC-NMR microprobe. Unambiguous discrimination of the peptides was possible via effect of chemical shifts of phosphorylation on the aromatic tyrosine protons. With the microprobe and the detection volume of 1.5 microl, it was possible to perform structure elucidation with the very small amounts available for the various peptides. For the syringe injection, 15 microg of the analyte were used (corresponding to ca 2 mg in classical 5-mm tubes). Capillary HPLC-NMR spectra were recorded in the stopped-flow mode from less than 400 ng of each peptide, using 1D and 2D techniques ((1)H,(1)H-COSY-90, (1)H/(13)C-HSQC, and (1)H/(13)C-HMBC).
Collapse
Affiliation(s)
- Petra Hentschel
- Institute of Organic Chemistry, University of Tübingen, Germany
| | | | | | | | | | | |
Collapse
|
38
|
Webb AG. Microcoil nuclear magnetic resonance spectroscopy. J Pharm Biomed Anal 2005; 38:892-903. [PMID: 16087050 DOI: 10.1016/j.jpba.2005.01.048] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2004] [Revised: 01/15/2005] [Accepted: 01/22/2005] [Indexed: 11/16/2022]
Abstract
In comparison with most analytical chemistry techniques, nuclear magnetic resonance has an intrinsically low sensitivity, and many potential applications are therefore precluded by the limited available quantity of certain types of sample. In recent years, there has been a trend, both commercial and academic, towards miniaturization of the receiver coil in order to increase the mass sensitivity of NMR measurements. These small coils have also proved very useful in coupling NMR detection with commonly used microseparation techniques. A further development enabled by small detectors is parallel data acquisition from many samples simultaneously, made possible by incorporating multiple receiver coils into a single NMR probehead. This review article summarizes recent developments and applications of "microcoil" NMR spectroscopy.
Collapse
Affiliation(s)
- A G Webb
- Department of Electrical and Computer Engineering, and Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 4221 Beckman Institute, 405 N. Mathews, Urbana, IL 61801, USA.
| |
Collapse
|
39
|
Xiao HB, Krucker M, Putzbach K, Albert K. Capillary liquid chromatography–microcoil 1H nuclear magnetic resonance spectroscopy and liquid chromatography–ion trap mass spectrometry for on-line structure elucidation of isoflavones in Radix astragali. J Chromatogr A 2005; 1067:135-43. [PMID: 15844518 DOI: 10.1016/j.chroma.2005.01.015] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Miniaturization and hyphenation of chromatographic separation techniques to nuclear magnetic resonance spectroscopy is being increasingly demanded in the field of biomedical, drug metabolite and natural product analysis. Herein, capillary liquid chromatography was coupled on-line to microcoil 1H nuclear magnetic resonance spectroscopy (capLC-NMR) equipped with a 1.5 microL solenoidal probe for structure elucidation of isoflavones in Radix astragali. The extract was screened by HPLC-UV-MS as the preliminary step and four major peaks were identified tentatively by ion trap mass spectrometry molecular weights and characteristic fragments. Then, stopped-flow capLC-UV-NMR was performed using 33 microg extract injected on-column. The four peaks were parked manually in the micro probe one by one and corresponding 1H NMR spectra were recorded with good resolutions under the applied capLC-NMR conditions (120 and 220 ng injected on-column for peaks 2 and 4, respectively). All aromatic regions of 1H NMR spectra correlated well to the characteristic signals of isoflavone aglycone protons. And the signal corresponding to the anomeric proton of the glucopyranoside of isoflavone glycoside was also obtained for peak 1. Therefore, these four peaks are determined as calycosin-7-O-beta-D-glucopyranoside (1), ononin (2), calycosin (3) and formononetin (4) unambiguously. The capLC-NMR results indicate that this hyphenated technique could be used for the determination of a great variety of natural products from small sample amounts, e.g., only 5 g R. astragali in this study.
Collapse
Affiliation(s)
- H B Xiao
- University of Tuebingen, Institute of Organic Chemistry, Auf der Morgenstelle 18, D-72076 Tuebingen, Germany
| | | | | | | |
Collapse
|
40
|
Zhang X, Webb AG. Magnetic resonance microimaging and numerical simulations of velocity fields inside enlarged flow cells used for coupled NMR microseparations. Anal Chem 2005; 77:1338-44. [PMID: 15732916 PMCID: PMC2754838 DOI: 10.1021/ac048532b] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The coupling of various chemical microseparation methods with small-scale NMR detection is a growing area in analytical chemistry. The formation of enlarged flow cells within the active volume of the NMR detector can significantly increase the coil filling factor and hence the signal-to-noise ratio of the NMR spectra. However, flow cells can also lead to deterioration of the separation efficiency due to the development of complex flow patterns, the form of which depend on the particular geometry of the flow cell and the flow rate used. In this study, we investigated the flow characteristics in different flow cell geometries relevant to the coupling of capillary liquid chromatography and NMR. Computational fluid dynamics was used to simulate fluid flow inside flow cells with a volume of approximately 1 microL. Magnetic resonance microimaging was used to measure experimentally the velocity fields inside these flow cells. The results showed good agreement between experiment and simulation and demonstrated that a relatively gradual expansion and contraction is necessary to avoid areas of weak recirculation and strong radial velocities, both of which can potentially compromise separation efficiency.
Collapse
Affiliation(s)
- Xiaofeng Zhang
- Department of Electrical and Computer Engineering; and Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana—Champaign, Urbana, Illinois 61801
| | - Andrew G. Webb
- Department of Electrical and Computer Engineering; and Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana—Champaign, Urbana, Illinois 61801
| |
Collapse
|
41
|
Abstract
This review discusses the development of capillary electrochromatography (CEC) coupled to mass spectrometric (MS) detection over the last few years. Major topics addressed are instrumental setups employed and applications of this technology published in the recent literature. The instrumental section includes a discussion of the most commonly used interfaces for the hyphenation of CEC and MS as well as ionization techniques. Applications reviewed in this paper come from a variety of different fields such as the analysis of biomolecules like proteins, peptides, amino acids or carbohydrates, chiral separations or the analysis of pharmaceutical an their metabolites in a series of matrices.
Collapse
Affiliation(s)
- Christian W Klampfl
- Institute of Analytical Chemistry, Johannes-Kepler-University, Altenbergerstrasse 69, A-4040 Linz, Austria.
| |
Collapse
|
42
|
Collins RN. Separation of low-molecular mass organic acid–metal complexes by high-performance liquid chromatography. J Chromatogr A 2004; 1059:1-12. [PMID: 15628118 DOI: 10.1016/j.chroma.2004.10.026] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The solution speciation of metals is a critical parameter controlling the bioavailability, solution-solid phase distribution and transport of metals in soils. The natural metal-complexing ligands that exist in soil solution include inorganic anions, inorganic colloids, organic humic substances, amino acids (notably phytosiderophores and bacterial siderophores) and low-molecular mass organic acids. The latter two groups are of particular significance in the soil surrounding plant roots (the rhizosphere). A number of analytical methodologies, encompassing computational, spectroscopic, physico-chemical and separation techniques, have been applied to the measurement of the solution speciation of metals in the environment. However, perhaps with the exception of the determination of the free metal cation, the majority of these techniques rarely provide species specific information. High-performance liquid chromatography (HPLC) coupled to a sensitive detection system, such as inductively coupled plasma mass spectrometry (ICP-MS) or electrospray ionisation mass spectrometry (ESI-MS), offers the possibility of separating and detecting metal-organic acid complexes at the very low concentrations normally found in the soil environment. This review, therefore, critically examines the literature reporting the HPLC separation of metal-organic acid complexes with reference to thermodynamic equilibrium and kinetic considerations. The limitations of HPLC techniques (and the use of thermodynamic equilibrium calculations to validate analytical results) are discussed and the metal complex characteristics necessary for chromatographic separation are described.
Collapse
Affiliation(s)
- Richard N Collins
- Laboratoire Pierre Süe, CEA-CNRS UMR 9956, 91191 Gif sur Yvette Cedex, France.
| |
Collapse
|
43
|
Jayawickrama DA, Sweedler JV. Dual Microcoil NMR Probe Coupled to Cyclic CE for Continuous Separation and Analyte Isolation. Anal Chem 2004; 76:4894-900. [PMID: 15307803 DOI: 10.1021/ac049390o] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Capillary electrophoresis (CE)-nuclear magnetic resonance (NMR) spectroscopy combines the separation efficiency of CE and the information-rich detection capabilities of NMR. However, the temporally narrow CE peaks reduce NMR sensitivity and prevent on-line multidimensional NMR acquisitions. In this work, cyclic CE with multicoil NMR instrumentation is developed to perform CE in multiple closed loops. As a proof of concept, a two-loop five-junction capillary configuration creates two connected yet independently operable fluidic loops. With appropriate voltage switching, analytes can be directed as desired around or between the loops, and a particular analyte band can be parked in one NMR detector coil while CE continues in the second loop and monitored with a second NMR detector coil. The separation of a mixture of amino acids (Ala, Val, Thr) is achieved in two cycles. After one CE cycle, Ala is separated and COSY data are recorded in one loop while Val and Thr are separated in the second loop. At the end of the second cycle, both Val and Thr are separated and multidimensional NMR spectra acquired. With this instrumentation and appropriate protocols, two-dimensional NMR data acquisition and CE separation are achieved simultaneously.
Collapse
Affiliation(s)
- Dimuthu A Jayawickrama
- Department of Chemistry and the Beckman Institute, University of Illinois, Urbana, Illinois 61801, USA
| | | |
Collapse
|
44
|
Krucker M, Lienau A, Putzbach K, Grynbaum MD, Schuler P, Albert K. Hyphenation of Capillary HPLC to Microcoil 1H NMR Spectroscopy for the Determination of Tocopherol Homologues. Anal Chem 2004; 76:2623-8. [PMID: 15117207 DOI: 10.1021/ac030379i] [Citation(s) in RCA: 68] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Highly selective reversed phases (C(30) phases) are self-packed in 250 microm inner diameter fused-silica capillaries and employed for capillary HPLC separation of shape-constrained natural compounds (tocopherol homologues, vitamin E). Miniaturized hyphenated systems such as capillary HPLC-ESI-MS (positive ionization mode) and, with special emphasis, continuous-flow capillary HPLC- NMR are used for structural determination of the separated compounds. Despite the small amount of sample available (1.33 microg of each tocopherol), the authors have been able to monitor the capillary HPLC separation under continuous-flow (1)H NMR conditions, thus allowing an immediate peak identification. Further structural assignment was carried out in the stopped-flow NMR mode as shown, for example, by a 2D (1)H,(1)H COSY NMR spectrum of alpha-tocopherol. We demonstrate in this paper the considerable potential of hyphenated capillary separations coupled to MS and NMR for the investigation of restricted amounts of sample.
Collapse
Affiliation(s)
- Manfred Krucker
- Institute of Organic Chemistry, University of Tübingen, Auf der Morgenstelle 18, D-72076 Tübingen, Germany
| | | | | | | | | | | |
Collapse
|
45
|
Wolfender JL, Ndjoko K, Hostettmann K. Liquid chromatography with ultraviolet absorbance-mass spectrometric detection and with nuclear magnetic resonance spectroscopy: a powerful combination for the on-line structural investigation of plant metabolites. J Chromatogr A 2003; 1000:437-55. [PMID: 12877183 DOI: 10.1016/s0021-9673(03)00303-0] [Citation(s) in RCA: 97] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
In order to discover new bioactive compounds from plant sources which could become new leads or new drugs, extracts should be submitted at the same time to chemical screening and to various biological or pharmacological targets. Metabolite profiling using hyphenated techniques such as LC/UV, LC/MS and more recently LC/NMR, quickly provides plenty of structural information, leading to a partial or a complete on-line de novo structure determination of the natural products of interest. As a complement to this approach, bioassays performed after LC/microfractionation of the extracts allow efficient localisation of the bioactive LC-peaks in the chromatograms. The combination of metabolite profiling and LC/bioassays provides the possibility of distinguishing between already known bioactive compounds (dereplication) and new molecules directly in crude plant extracts. Thus, the tedious isolation of compounds of low interest can be avoided and targeted isolation of new bioactive products or constituents presenting novel or unusual spectroscopic features can be undertaken. Several examples of rapid localisation of bioactive compounds, based on post-chromatographic bioautographic testing of LC/NMR microfractions and subsequent on-line identification will be illustrated. Application of hyphenated techniques for the efficient characterisation of labile constituents or constituents difficult to separate at the preparative scale will also be mentioned. The possibilities and limitations of LC/UV/NMR/MS and LC/bioassay as well as future development expected in this field will be discussed.
Collapse
Affiliation(s)
- Jean-Luc Wolfender
- Institut de Pharmacognosie et Phytochimie, Université de Lausanne, BEP, CH-1015 Lausanne, Switzerland.
| | | | | |
Collapse
|