• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4613499)   Today's Articles (6729)   Subscriber (49388)
For: Morf WE, Badertscher M, Zwickl T, de Rooij NF, Pretsch E. Effects of controlled current on the response behavior of polymeric membrane ion-selective electrodes. J Electroanal Chem (Lausanne) 2002;526:19-28. [DOI: 10.1016/s0022-0728(02)00756-8] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Number Cited by Other Article(s)
1
Kalisz J, Węgrzyn K, Michalska A, Maksymiuk K. Resolution increase of ion-selective electrodes response by using a reversed amperometric setup. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.140886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
2
Kałuża D, Michalska A, Maksymiuk K. Solid‐Contact Ion‐Selective Electrodes Paving the Way for Improved Non‐Zero Current Sensors: A Minireview. ChemElectroChem 2021. [DOI: 10.1002/celc.202100892] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
3
Lisak G. Reliable environmental trace heavy metal analysis with potentiometric ion sensors - reality or a distant dream. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2021;289:117882. [PMID: 34364114 DOI: 10.1016/j.envpol.2021.117882] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2021] [Revised: 07/13/2021] [Accepted: 07/29/2021] [Indexed: 06/13/2023]
4
Park S, Maier CS, Koley D. Anodic Stripping Voltammetry on a Carbon-based Ion-Selective Electrode. Electrochim Acta 2021;390:138855. [PMID: 34483347 PMCID: PMC8415442 DOI: 10.1016/j.electacta.2021.138855] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
5
Kondratyeva YO, Solovyeva EV, Khripoun GA, Mikhelson KN. Paradox of the Variation of the Bulk Resistance of Potassium Ion-Selective Electrode Membranes within Nernstian Potentiometric Response Range. RUSS J ELECTROCHEM+ 2019. [DOI: 10.1134/s1023193519110090] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
6
Bilayer membranes for ion-selective electrodes. J Electroanal Chem (Lausanne) 2016. [DOI: 10.1016/j.jelechem.2016.01.040] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
7
Mikhelson KN, Peshkova MA. Advances and trends in ionophore-based chemical sensors. RUSSIAN CHEMICAL REVIEWS 2015. [DOI: 10.1070/rcr4506] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
8
Solvent polymeric membrane ion-selective electrodes under galvanostatic control: Powerful tool for analysis of extremely diluted samples. Electrochim Acta 2013. [DOI: 10.1016/j.electacta.2013.03.077] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
9
Almeida S, Montenegro M, Sales M. New and low cost plastic membrane electrode with low detection limits for sulfadimethoxine determination in aquaculture waters. J Electroanal Chem (Lausanne) 2013. [DOI: 10.1016/j.jelechem.2013.09.029] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
10
Zou XU, Bühlmann P. Current Pulse Based Reference Electrodes Without Liquid Junctions. Anal Chem 2013;85:3817-21. [DOI: 10.1021/ac400507j] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
11
Ghahraman Afshar M, Crespo GA, Bakker E. Direct Ion Speciation Analysis with Ion-Selective Membranes Operated in a Sequential Potentiometric/Time Resolved Chronopotentiometric Sensing Mode. Anal Chem 2012;84:8813-21. [DOI: 10.1021/ac302092m] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
12
Skórska L, Michalska A, Wojciechowski M, Bulska E, Maksymiuk K. Estimation of primary silver ions contents in poly(vinyl chloride) ion-selective membranes using chronopotentiometry and mass spectrometry. Electrochim Acta 2012. [DOI: 10.1016/j.electacta.2011.12.066] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
13
Lisak G, Sokalski T, Bobacka J, Harju L, Mikhelson K, Lewenstam A. Tuned galvanostatic polarization of solid-state lead-selective electrodes for lowering of the detection limit. Anal Chim Acta 2011;707:1-6. [DOI: 10.1016/j.aca.2011.09.026] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2011] [Revised: 09/10/2011] [Accepted: 09/13/2011] [Indexed: 10/17/2022]
14
Pawłowski P, Kisiel A, Michalska A, Maksymiuk K. Potentiometric responses of ion-selective electrodes after galvanostatically controlled incorporation of primary ions. Talanta 2011;84:814-9. [DOI: 10.1016/j.talanta.2011.02.018] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2010] [Revised: 02/02/2011] [Accepted: 02/14/2011] [Indexed: 10/18/2022]
15
Peshkova MA, Mikhel’son KN. Ion-selective electrodes under galvanostatic polarization conditions. RUSS J ELECTROCHEM+ 2010. [DOI: 10.1134/s1023193510110054] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
16
Mikhelson KN. Ion-selective electrodes with sensitivity in strongly diluted solutions. JOURNAL OF ANALYTICAL CHEMISTRY 2010. [DOI: 10.1134/s1061934810020024] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
17
Memory Effects of Ion-Selective Electrodes: Theory and Computer Simulation of the Time-Dependent Potential Response to Multiple Sample Changes. J Electroanal Chem (Lausanne) 2009;633:137-145. [PMID: 20376292 DOI: 10.1016/j.jelechem.2009.05.004] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
18
Höfler L, Bedlechowicz I, Vigassy T, Gyurcsányi RE, Bakker E, Pretsch E. Limitations of current polarization for lowering the detection limit of potentiometric polymeric membrane sensors. Anal Chem 2009;81:3592-9. [PMID: 19338286 DOI: 10.1021/ac802588j] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
19
Sokalski T, Kucza W, Danielewski M, Lewenstam A. Time-Dependent Phenomena in the Potential Response of Ion-Selective Electrodes Treated by the Nernst−Planck−Poisson Model. Part 2: Transmembrane Processes and Detection Limit. Anal Chem 2009;81:5016-22. [DOI: 10.1021/ac900490c] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
20
Peshkova MA, Sokalski T, Mikhelson KN, Lewenstam A. Obtaining Nernstian Response of a Ca2+-Selective Electrode in a Broad Concentration Range by Tuned Galvanostatic Polarization. Anal Chem 2008;80:9181-7. [DOI: 10.1021/ac8013143] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
21
Xu Y, Ngeontae W, Pretsch E, Bakker E. Backside calibration chronopotentiometry: using current to perform ion measurements by zeroing the transmembrane ion flux. Anal Chem 2008;80:7516-23. [PMID: 18778039 PMCID: PMC2597783 DOI: 10.1021/ac800774e] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
22
Element profiles in galvanostatically polarized K+-selective all-solid-state sensors with poly(vinyl chloride)-based membranes. J Solid State Electrochem 2008. [DOI: 10.1007/s10008-008-0578-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
23
Morf WE, Pretsch E, De Rooij NF. Theory and Computer Simulation of the Time-Dependent Selectivity Behavior of Polymeric Membrane Ion-Selective Electrodes. J Electroanal Chem (Lausanne) 2008;614:15-23. [PMID: 20411043 DOI: 10.1016/j.jelechem.2007.10.027] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
24
Bhakthavatsalam V, Bakker E. Operational Limits of Controlled Current Coulometry with Ion-Selective Polymeric Membranes. ELECTROANAL 2008. [DOI: 10.1002/elan.200703979] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
25
Zook JM, Buck RP, Langmaier J, Lindner E. Mathematical model of current-polarized ionophore-based ion-selective membranes. J Phys Chem B 2008;112:2008-15. [PMID: 18217742 DOI: 10.1021/jp074612i] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
26
Bobacka J, Ivaska A, Lewenstam A. Potentiometric Ion Sensors. Chem Rev 2008;108:329-51. [DOI: 10.1021/cr068100w] [Citation(s) in RCA: 675] [Impact Index Per Article: 42.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
27
Influence of galvanostatic polarisation on evolution of ion concentration profiles in ion-selective membranes, studied by means of laser ablation inductively coupled plasma mass spectrometry. Electrochem commun 2008. [DOI: 10.1016/j.elecom.2007.10.026] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]  Open
28
Bakker E, Pretsch E. Moderne Potentiometrie. Angew Chem Int Ed Engl 2007. [DOI: 10.1002/ange.200605068] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
29
Morf WE, Pretsch E, De Rooij NF. Computer Simulation of Ion-Selective Membrane Electrodes and Related Systems by Finite-Element Procedures. J Electroanal Chem (Lausanne) 2007;602:43-54. [PMID: 20376294 PMCID: PMC2849319 DOI: 10.1016/j.jelechem.2006.11.025] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
30
Bakker E, Pretsch E. Modern potentiometry. Angew Chem Int Ed Engl 2007;46:5660-8. [PMID: 17457791 PMCID: PMC2515866 DOI: 10.1002/anie.200605068] [Citation(s) in RCA: 207] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
31
Konopka A, Sokalski T, Lewenstam A, Maj-Żurawska M. The Influence of the Conditioning Procedure on Potentiometric Characteristics of Solid Contact Calcium-Selective Electrodes in Nanomolar Concentration Solutions. ELECTROANAL 2006. [DOI: 10.1002/elan.200603652] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
32
Pawłowski P, Michalska A, Maksymiuk K. Galvanostatic Polarization of All-Solid-State K+-Selective Electrodes with Polypyrrole Ion-to-Electron Transducer. ELECTROANAL 2006. [DOI: 10.1002/elan.200603553] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
33
Szigeti Z, Vigassy T, Bakker E, Pretsch E. Approaches to Improving the Lower Detection Limit of Polymeric Membrane Ion-Selective Electrodes. ELECTROANAL 2006;18:1254-1265. [PMID: 20336172 PMCID: PMC2844646 DOI: 10.1002/elan.200603539] [Citation(s) in RCA: 74] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2006] [Accepted: 04/03/2006] [Indexed: 11/10/2022]
34
Sutter J, Pretsch E. Response Behavior of Poly(vinyl chloride)- and Polyurethane-Based Ca2+-Selective Membrane Electrodes with Polypyrrole- and Poly(3-octylthiophene)-Mediated Internal Solid Contact. ELECTROANAL 2006. [DOI: 10.1002/elan.200503373] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
35
Michalska A. Optimizing the analytical performance and construction of ion-selective electrodes with conducting polymer-based ion-to-electron transducers. Anal Bioanal Chem 2005;384:391-406. [PMID: 16365779 DOI: 10.1007/s00216-005-0132-4] [Citation(s) in RCA: 66] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2005] [Revised: 09/07/2005] [Accepted: 09/21/2005] [Indexed: 11/28/2022]
36
Influence of cationic and anionic additives on the electrical properties of ionophore-based ion-selective membranes. J Electroanal Chem (Lausanne) 2005. [DOI: 10.1016/j.jelechem.2005.04.029] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
37
Michalska A, Maksymiuk K. The influence of spontaneous charging/discharging of conducting polymer ion-to-electron transducer on potentiometric responses of all-solid-state calcium-selective electrodes. J Electroanal Chem (Lausanne) 2005. [DOI: 10.1016/j.jelechem.2004.10.030] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
38
Michalska A. Improvement of Analytical Characteristic of Calcium Selective Electrode with Conducting Polymer Contact. The Role of Conducting Polymer Spontaneous Charge Transfer Processes and Their Galvanostatic Compensation. ELECTROANAL 2005. [DOI: 10.1002/elan.200403173] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
39
Michalska A, Maksymiuk K. All-plastic, disposable, low detection limit ion-selective electrodes. Anal Chim Acta 2004. [DOI: 10.1016/j.aca.2004.07.020] [Citation(s) in RCA: 76] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
40
Sutter J, Radu A, Peper S, Bakker E, Pretsch E. Solid-contact polymeric membrane electrodes with detection limits in the subnanomolar range. Anal Chim Acta 2004. [DOI: 10.1016/j.aca.2004.07.016] [Citation(s) in RCA: 179] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
41
Sutter J, Morf WE, de Rooij NF, Pretsch E. Current response of ion-selective solvent polymeric membranes at controlled potential. J Electroanal Chem (Lausanne) 2004. [DOI: 10.1016/j.jelechem.2004.04.009] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
42
Püntener M, Vigassy T, Baier E, Ceresa A, Pretsch E. Improving the lower detection limit of potentiometric sensors by covalently binding the ionophore to a polymer backbone. Anal Chim Acta 2004. [DOI: 10.1016/j.aca.2003.10.030] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
43
Vigassy T, Gyurcsányi R, Pretsch E. Influence of Incorporated Lipophilic Particles on Ion Fluxes Through Polymeric Ion-Selective Membranes. ELECTROANAL 2003. [DOI: 10.1002/elan.200390043] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA