1
|
Patel MP, Parmar VB, Rami DS, Rakesh Trivedi V, Rana DM, Bajania DN. Comparative Evaluation of the Effect of Microwave, 1% Sodium Hypochlorite, and Sodium Perborate Disinfection on the Color Stability of Two Nanoparticle-Reinforced Heat-Polymerized PMMA Denture Base Resins: An In Vitro Study. Cureus 2024; 16:e67350. [PMID: 39310436 PMCID: PMC11415167 DOI: 10.7759/cureus.67350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2024] [Accepted: 08/15/2024] [Indexed: 09/25/2024] Open
Abstract
Introduction Older adults experience significant improvement in their quality of life by using removable prosthetics to replace missing teeth. Poly(methyl methacrylate) (PMMA) has become the most popular material for denture bases due to its ease of use and affordability. Recently, scientists have started adding nanoparticles like titanium dioxide (TiO2) and zirconium oxide (ZrO2) to PMMA to enhance its physical properties. These resins with nanoparticles need to stay the same color after being disinfected in different ways if they are going to be used for a long time. So, the purpose of this investigation was to assess whether or not there exists any difference between two kinds of thermally cured acrylic resin for artificial tooth bases strengthened with nanoparticles when subjected to various chemical sterilizers alongside microwave irradiation, as well as determine their comparative colorfastness levels. Materials and methods In this lab experiment, we tested how well 5% TiO2 and 7% ZrO2 nanoparticle-reinforced PMMA resins held their color when exposed to microwave irradiation, 1% sodium hypochlorite, or sodium perborate disinfection. We made 120 specimens shaped like discs; half were treated using one method, while the other half were treated using a different method. Color was measured at baseline (T0), after one cycle (T1), after five cycles (T2), and after six months (T3) using a reflectance spectrophotometer, which calculates the color difference (∆E). Results All three methods of disinfection caused significant color changes (p<0.001); however, sodium perborate caused the least amount of change, followed by 1% sodium hypochlorite and microwave irradiation. The mean ∆E values showed that after one day, there was a change in color by 1.1 due to microwave disinfection, which increased to 5.7 after five days; on the other hand, for 1% sodium hypochlorite, the change was recorded as 0.7 after one month and 1.6 after three months and finally reached up to 2.6 after six months, while sodium perborate showed the least amount of change, with ∆E values recorded as 0.2 after one month, 0.5 after three months, and 0.8 after six months. Conclusion Sodium perborate proved to be the most effective disinfectant for maintaining color stability in 5% TiO2 and 7% ZrO2 nanoparticle-reinforced PMMA resins, thus making it ideal for routine disinfection. Therefore, according to this study, sodium perborate should be used as a disinfection method because it results in minimal color change in nanoparticle-reinforced PMMA dentures.
Collapse
Affiliation(s)
- Mrugnayani P Patel
- Department of Prosthodontics and Crown & Bridge, Manubhai Patel Dental College, Vadodara, IND
| | - Vishal B Parmar
- Department of Prosthodontics and Crown & Bridge, Narsinhbhai Patel Dental College and Hospital, Sankalchand Patel University, Visnagar, IND
| | - Diptesh S Rami
- Department of Prosthodontics and Crown & Bridge, Ahmedabad Municipal Corporation (AMC) Dental College and Hospital, Ahmedabad, IND
| | - Vishal Rakesh Trivedi
- Department of Prosthodontics and Crown & Bridge, Manubhai Patel Dental College, Vadodara, IND
| | - Dhaara M Rana
- Department of Prosthodontics and Crown & Bridge, Government Dental College and Hospital, Jamnagar, IND
| | - Dhara N Bajania
- Department of Prosthodontics and Crown & Bridge, Government Dental College and Hospital, Jamnagar, IND
| |
Collapse
|
2
|
Altarazi A, Haider J, Alhotan A, Silikas N, Devlin H. Impact of Artificial Aging on the Physical and Mechanical Characteristics of Denture Base Materials Fabricated via 3D Printing. Int J Biomater 2024; 2024:8060363. [PMID: 38919543 PMCID: PMC11199068 DOI: 10.1155/2024/8060363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 05/09/2024] [Accepted: 05/31/2024] [Indexed: 06/27/2024] Open
Abstract
Three-dimensional (3D) printing is becoming more prevalent in the dental sector due to its potential to save time for dental practitioners, streamline fabrication processes, enhance precision and consistency in fabricating prosthetic models, and offer cost-effective solutions. However, the effect of aging in artificial saliva of this type of material has not been explored. To assess the physical and mechanical properties of the two types of 3D-printed materials before and after being subjected to artificial saliva, a total of 219 acrylic resin specimens were produced. These specimens were made with two types of 3D-printed materials, namely, NextDent (ND) and Formlabs (FLs), and a Schottlander heat-cured (HC) resin material that was used as a control. Water sorption and solubility specimens (n = 5) were tested after three months of storage in artificial saliva. Moreover, the Vickers hardness, Martens hardness, flexural strength/modulus, and impact strength were evaluated both under dry conditions and after three months of storage in artificial saliva. The degree of conversion (DC), elemental analysis, and filler content were also investigated. The ANOVA showed that 3D-printed resins had significantly greater sorption than the control group (p < 0.05). However, the flexural strength values of the 3D-printed materials were significantly greater (p < 0.05) than those of the heat-cured material. The DC of the 3D-printed resins was lower than that of the control group, but the difference was not significant (p > 0.05). The 3D-printed materials contained significantly more filler than the control (p < 0.05). Moreover, the artificial saliva had a significant effect on the Vickers hardness for all tested groups and on the Martens hardness for the control group only (p < 0.05). Compared with conventional heat-cured materials, 3D-printed denture base materials demonstrated relatively poorer performance in terms of sorption, solubility, and DC but exhibited either comparable or superior mechanical properties. The aging process also influenced the Vickers and Martens' hardness. The strength of the 3D-printed materials was in compliance with ISO recommendations, and the materials could be used alongside conventional heat-cured materials.
Collapse
Affiliation(s)
- Ahmed Altarazi
- Division of Dentistry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, UK
- Restorative Dental Science, College of Dentistry, Taibah University, Medinah, Saudi Arabia
| | - Julfikar Haider
- Division of Dentistry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, UK
- Department of Engineering, Manchester Metropolitan University, Manchester M1 5GD, UK
| | - Abdulaziz Alhotan
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Nick Silikas
- Division of Dentistry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, UK
| | - Hugh Devlin
- Division of Dentistry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, UK
- School of Dentistry, University of Jordan, Amman, Jordan
| |
Collapse
|
3
|
Altarazi A, Haider J, Alhotan A, Silikas N, Devlin H. 3D printed denture base material: The effect of incorporating TiO 2 nanoparticles and artificial ageing on the physical and mechanical properties. Dent Mater 2023; 39:1122-1136. [PMID: 37839997 DOI: 10.1016/j.dental.2023.10.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 09/16/2023] [Accepted: 10/05/2023] [Indexed: 10/17/2023]
Abstract
OBJECTIVES To evaluate the physical and mechanical properties of three-dimensional (3D) printed denture base resin incorporating TiO2 nanoparticles (NPs), subjected to a physical ageing process. METHODS Acrylic denture base samples were prepared by a Stereolithography (SLA) 3D printing technique reinforced with different concentrations (0.10, 0.25, 0.50, and 0.75) of silanated TiO2 NPs. The resulting nanocomposite materials were characterized in terms of degree of conversion (DC), and sorption/solubility flexural strength, impact strength, Vickers hardness and Martens hardness and compared with unmodified resin and conventional heat-cured (HC) material. The nanocomposites were reassessed after subjecting them to ageing in artificial saliva. A fractured surface was studied under a scanning electron microscope (SEM). RESULTS The addition of TiO2 NPs into 3D-printed resin significantly improved flexural strength/modulus, impact strength, Vickers hardness, and DC, while also slightly enhancing Martens hardness compared to the unmodified resin. Sorption values did not show any improvements, while solubility was reduced significantly. The addition of 0.10 wt% NPs provided the highest performance amongst the other concentrations, and 0.75 wt% NPs showed the lowest. Although ageing degraded the materials' performance to a certain extent, the trends remained the same. SEM images showed a homogenous distribution of the NPs at lower concentrations (0.10 and 0.25 wt%) but revealed agglomeration of the NPs with the higher concentrations (0.50 and 0.75 wt%). SIGNIFICANCE The outcomes of this study suggested that the incorporation of TiO2 NPs (0.10 wt%) into 3D-printed denture base material showed superior performance compared to the unmodified 3D-printed resin even after ageing in artificial saliva. The nanocomposite has the potential to extend service life of denture bases in future clinical use.
Collapse
Affiliation(s)
- Ahmed Altarazi
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, United Kingdom; Restorative Dental Science, College of Dentistry, Taibah University, Saudi Arabia.
| | - Julfikar Haider
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, United Kingdom; Department of Engineering, Manchester Metropolitan University, Manchester, United Kingdom
| | - Abdulaziz Alhotan
- Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Nick Silikas
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, United Kingdom.
| | - Hugh Devlin
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, United Kingdom
| |
Collapse
|
4
|
Osman RB, Khoder G, Fayed B, Kedia RA, Elkareimi Y, Alharbi N. Influence of Fabrication Technique on Adhesion and Biofilm Formation of Candida albicans to Conventional, Milled, and 3D-Printed Denture Base Resin Materials: A Comparative In Vitro Study. Polymers (Basel) 2023; 15:polym15081836. [PMID: 37111983 PMCID: PMC10146129 DOI: 10.3390/polym15081836] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 03/16/2023] [Accepted: 03/29/2023] [Indexed: 04/29/2023] Open
Abstract
The aim of this study was to evaluate the adhesion and biofilm formation of Candida albicans (C. albicans) on conventionally fabricated, milled, and 3D-printed denture base resin materials in order to determine the susceptibility of denture contamination during clinical use. Specimens were incubated with C. albicans (ATCC 10231) for 1 and 24 h. Adhesion and biofilm formation of C. albicans were assessed using the field emission scanning electron microscopy (FESEM). The XTT (2,3-(2-methoxy-4-nitro-5-sulphophenyl)-5-[(phenylamino) carbonyl]-2H-tetrazolium hydroxide) assay was used for the quantification of fungal adhesion and biofilm formation. The data were analyzed using GraphPad Prism 8.02 for windows. One-way ANOVA with Tukey's post hoc testing were performed with a statistical significance level set at α = 0.05. The quantitative XTT biofilm assay revealed significant differences in the biofilm formation of C. albicans between the three groups in the 24 h incubation period. The highest proportion of biofilm formation was observed in the 3D-printed group, followed by the conventional group, while the lowest candida biofilm formation was observed in the milled group. The difference in biofilm formation among the three tested dentures was statistically significant (p < 0.001). The manufacturing technique has an influence on the surface topography and microbiological properties of the fabricated denture base resin material. Additive 3D-printing technology results in increased candida adhesion and the roughest surface topography of maxillary resin denture base as compared to conventional flask compression and CAD/CAM milling techniques. In a clinical setting, patients wearing additively manufactured maxillary complete dentures are thus more susceptible to the development of candida-associated denture stomatitis and accordingly, strict oral hygiene measures and maintenance programs should be emphasized to patients.
Collapse
Affiliation(s)
- Reham B Osman
- Department of Prosthodontics, Faculty of Dentistry, Cairo University, Giza 12613, Egypt
| | - Ghalia Khoder
- Department of Pharmaceutics and Pharmaceutical Technology, College of Pharmacy, University of Sharjah, Sharjah P.O. Box 27272, United Arab Emirates
- Research Institute for Medical and Health Sciences, University of Sharjah, Sharjah P.O. Box 27272, United Arab Emirates
| | - Bahgat Fayed
- Research Institute for Medical and Health Sciences, University of Sharjah, Sharjah P.O. Box 27272, United Arab Emirates
- Chemistry of Natural and Microbial Products Department, National Research Center, Giza 12622, Egypt
| | - Reena Arora Kedia
- Research Institute for Medical and Health Sciences, University of Sharjah, Sharjah P.O. Box 27272, United Arab Emirates
| | | | - Nawal Alharbi
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11451, Saudi Arabia
| |
Collapse
|
5
|
Mishra S, Chaturvedi S, Ali M, Pandey KK, Alqahtani NM, Alfarsi MA, Addas MK, Vaddamanu SK, Al Ahmari NM, Alqahtani SM, Yaqoob A, Alqahtani WMS. Dimensional Stability of Light-Activated Urethane Dimethacrylate Denture Base Resins. Polymers (Basel) 2023; 15:polym15030744. [PMID: 36772044 PMCID: PMC9921156 DOI: 10.3390/polym15030744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Revised: 01/26/2023] [Accepted: 01/28/2023] [Indexed: 02/04/2023] Open
Abstract
An accurate and dimensionally stable trial denture base is required for a successful denture. The aim of this in vitro study was to assess the dimensional stability of a light-activated urethane dimethacrylate (UDMA) visible light cure (VLC) denture base with three fabrication techniques and different curing cycles. Forty-five VLC denture base samples were divided evenly into three groups. Group A used a conventional fabrication technique with a curing cycle of 5 min. Group B used a modified fabrication technique with two 4-min curing cycles. Group C used a multi-step fabrication technique with three curing cycles (4 min, plus 4 min, plus 2 min). The samples were sectioned and observed under a stereomicroscope to measure the discrepancy between the sample and the master cast. The mean dimensional discrepancy (mm) at the molar region at mid-palate, after 24 h in Group A, B and C was 0.790 mm, 0.741 mm and 0.379 mm, respectively; at the right ridge crest, it was 0.567, 0.408 and 0.185, while at the left ridge crest it was 0.475, 0.331 and 0.125, respectively. Statistical analysis showed significantly different dimensional discrepancies among the groups at all three sites; right ridge crest (F = 93.54, p < 0.001), left ridge crest (F = 105.96, p < 0.001) and mid-palate (F = 125.53, p < 0.001). Within the limitations of this laboratory study, it can be concluded that the denture base using a multi-step fabrication technique with three curing cycles provides better adaptation than the conventional technique. The significance of the study is that clinicians should consider performing denture base fabrication using a multi-step technique to enhance adaptation and hence the stability of the dentures for patients.
Collapse
Affiliation(s)
- Swati Mishra
- Department of Prosthodontics, Career Postgraduate Institute of Dental Sciences, Lucknow 226008, India
| | - Saurabh Chaturvedi
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia
- Correspondence:
| | - Mariyam Ali
- Department of Prosthodontics, Career Postgraduate Institute of Dental Sciences, Lucknow 226008, India
| | - Kaushik Kumar Pandey
- Department of Prosthodontics, Career Postgraduate Institute of Dental Sciences, Lucknow 226008, India
| | - Nasser M. Alqahtani
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia
| | - Mohammed A. Alfarsi
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia
| | - Mohamed Khaled Addas
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia
| | - Sunil Kumar Vaddamanu
- Department of Dental Technology, College of Applied Medical Sciences, King Khalid University, Abha 61421, Saudi Arabia
| | - Nasser M. Al Ahmari
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia
| | - Saeed M. Alqahtani
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia
| | - Ashfaq Yaqoob
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia
| | - Waleed M. S. Alqahtani
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia
| |
Collapse
|
6
|
Wajdan N, Aslam K, Amin R, Khan S, Ahmed N, Lal A, AlHamdan EM, Vohra F, Abduljabbar T, Heboyan A. Anti-fungal efficacy of Miswak Extract (Salvadora Persica) and commercial cleaner against Candida albicans on heat cured polymethylmethacrylate denture base. J Appl Biomater Funct Mater 2023; 21:22808000231165666. [PMID: 37128650 DOI: 10.1177/22808000231165666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/03/2023] Open
Abstract
AIM The aim of the study was to compare the antifungal efficacy between commercial cleaner (Corega) and Miswak extract (Salvadora persica) against Candida albicans on heat cured Polymethyl methacrylate (PMMA) acrylic denture base resin. MATERIALS AND METHODS Forty-eight samples of heat cured PMMA acrylic denture base resin were fabircated in the study. The sterile acrylic resin specimens were immersed in standardized cell suspension of Candida albicans and incubated for 60 min at 370°C for cell adhesion and 2 h at 370°C for biofilm formation. After 24 h biofilm was evaluated by cell viability (CFUs) on SDA and cell counting of Candida albicans under light microscope at 400× magnification. The fungicidal effect of commercial cleaner and Miswak extract on Candida albicans biofilm was then evaluated by colony-forming units on SDA and cell counting under light microscope at 400× magnification. RESULTS Screening test agar disk-diffusion assay showed mean inhibitory zone of 3 mm for commercial cleaner as compared to Miswak extract, which showed mean inhibitory zone of 2 and 1 mm for different concentrations. Broth microdilution method showed 31 mg/ml MIC and 62.5 mg/ml Minimal Fungicidal Concentration (MFC) values for commercial cleaner as compared to Miswak extract that showed 125 mg/ml MIC and 250 mg/ml MFC values against Candida albicans. A significant difference (p < 0.05) was observed between pre and post treatment of both commercial cleaner and Miswak extract, for CFUs and cell count for Candida albicans. CONCLUSION Commercial denture cleaner (Corega) showed better antifungal (C albicans) activity than Miswak extract (Salvadora persica) on heat cured PMMA acrylic denture base resin.
Collapse
Affiliation(s)
- Nadia Wajdan
- Department of Prosthodontics, Dr. Ishrat-ul-Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences, Karachi, Sindh, Pakistan
| | - Kashif Aslam
- Department of Prosthodontics, Dow Dental College, Dow University of Health Sciences, Karachi, Sindh, Pakistan
| | - Rafat Amin
- Dow College of Biotechnology, Dow University of Health Sciences, Karachi, Sindh, Pakistan
| | - Sadaf Khan
- Dow College of Biotechnology, Dow University of Health Sciences, Karachi, Sindh, Pakistan
| | - Naseer Ahmed
- Department of Prosthodontics, Altamash Institute of Dental Medicine, Karachi, Pakistan
| | - Abhishek Lal
- Department of Prosthodontics, Altamash Institute of Dental Medicine, Karachi, Pakistan
| | - Eman M AlHamdan
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Fahim Vohra
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Tariq Abduljabbar
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Artak Heboyan
- Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Yerevan, Armenia
| |
Collapse
|
7
|
Ghorbanipour R, Teimoorian M, Mirzaie M, Tashakkorian H, Gholinia H, Alaghemand H, Pournajaf A. Effects of adding functionalized graphene oxide nanosheets on physical, mechanical, and anti-biofilm properties of acrylic resin: In vitro- experimental study. Dent Res J (Isfahan) 2023. [DOI: 10.4103/1735-3327.372654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023] Open
|
8
|
Antibacterial and Physical Properties of PVM/MA Copolymer- Incorporated Polymethyl Methacrylate as a Novel Antimicrobial Acrylic Resin Material. Molecules 2022; 27:molecules27248848. [PMID: 36557980 PMCID: PMC9781081 DOI: 10.3390/molecules27248848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 11/29/2022] [Accepted: 12/08/2022] [Indexed: 12/15/2022] Open
Abstract
Polymethyl methacrylate (PMMA), an acrylic resin used in orthodontic appliances and removable dentures for its biocompatibility and esthetics, may harbor bacteria on its surface. The present study investigated a new PMMA formula with Gantrez: an antibacterial copolymer of methyl vinyl ether and maleic acid (PVM/MA). Samples were tested for mechanical properties (surface hardness, flexural strength, water sorption, and water solubility) and effects against Streptococcus mutans. Six groups (0%-control, 5%, 10%, 15%, 20%, and 25% Gantrez) of n = 12 were fabricated for physical property tests and analyzed with one-way ANOVA and Prism 6. From these results, three groups (0%, 5%, and 10% Gantrez) were selected for antibacterial tests, and data were analyzed with one-way ANOVA and Tukey’s multiple comparison test. Adding 5% and 10% Gantrez into PMMA significantly decreased S. mutans adhesion. There was no significant difference between the control vs. 5%, 10%, 15%, and 20% Gantrez (p > 0.05) for surface hardness, the control vs. 5% Gantrez (p > 0.05) for flexural strength, and the control vs. 5 and 10% Gantrez for water sorption and water solubility. Overall, incorporating 5% Gantrez into PMMA may be a promising solution to reduce bacterial adhesion without changing the acrylic resin’s physical properties.
Collapse
|
9
|
El-Shaheed NH, Lamfon HA, Salama RI, Faramawy AMG, Mostafa AZH. Tissue Surface Adaptation and Clinical Performance of CAD-CAM Milled versus Conventional Implant-Assisted Mandibular Overdenture. Int J Dent 2022; 2022:8220233. [PMID: 35756959 PMCID: PMC9225844 DOI: 10.1155/2022/8220233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 05/18/2022] [Accepted: 06/02/2022] [Indexed: 12/03/2022] Open
Abstract
Purpose To evaluate the surface adaptation and maximal biting force of CAD-CAM milled mandibular overdenture (CAD-CAM MOD) compared to conventional compression mold mandibular overdenture (CC MOD). Materials and Methods Ten completely edentulous subjects with persistent complaints of their complete mandibular dentures were received four dental implants in the anterior mandible. Three months after osseointegration, subjects were randomly received either conventional compression mold or CAD-CAM MOD in a crossover design. To assess tissue surface adaptation, the fitting surfaces of each denture base were scanned and placed on the reference master cast. Three and six months after each overdenture was inserted, clinical performance in the form of maximum biting force was evaluated. Results The results of this study indicated that the tissue surface adaptation of the CAD-CAM MOD bases was significantly better than the conventional (compression mold technique) processed bases where (P=0.0001). Regarding clinical performance (maximum biting force), the CAD-CAM MOD exhibited better clinical performance (P=0.0001). Conclusions In denture processing methods, the CAD-CAM overdenture delivered more precise adaption and clinical performance than the compression mold technique.
Collapse
Affiliation(s)
- Noha H. El-Shaheed
- Prosthodontic Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Hanadi A. Lamfon
- Removable Prosthodontics, Faculty of Dentistry, Umm Al-Qura University, Makkah, Saudi Arabia
| | - Rabab. I. Salama
- Pediatric Dentistry and Dental Public Health Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Amira Mohammed Gomaa Faramawy
- Prosthodontic Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
- Removable Prosthodontics, Faculty of Dentistry, Umm Al-Qura University, Makkah, Saudi Arabia
| | | |
Collapse
|
10
|
Khurshid Z, Nedumgottil BM, Ali RMM, Bencharit S, Najeeb S. Insufficient Evidence to Ascertain the Long-Term Survival of PEEK Dental Prostheses: A Systematic Review of Clinical Studies. Polymers (Basel) 2022; 14:polym14122441. [PMID: 35746022 PMCID: PMC9231096 DOI: 10.3390/polym14122441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 06/11/2022] [Accepted: 06/15/2022] [Indexed: 11/16/2022] Open
Abstract
Introduction: Polyetheretherketone (PEEK) is a polymer that is used in the construction of orthopaedic and dental implants. It is also used to construct removable and fixed dental prostheses due to its superior mechanical and esthetic properties compared to conventional materials. This systematic review aims to analyse and appraise the literature concerning PEEK dental prostheses critically. Methods: The following focused question was constructed ‘Are dental prostheses made of PEEK inferior to those made of other materials in terms of clinical- and patient-reported outcomes?’. The CONSORT (Consolidated Standards of Reporting Trials) tool was used for the quality assessment of the randomised clinical trials. The STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) quality assessment tool was used to assess the quality of observational studies and the case reports were evaluated using the CARE (Case Report) guidelines. Results: A total of 12 studies were included in this review. Two case studies received an overall grade of medium and the overall quality of six studies was graded as ‘low’. All three observational studies and the only randomised controlled trial received scores of ‘medium’. Conclusion: PEEK-based dental prostheses may provide a viable and more esthetic alternative to conventional prosthodontic appliances. However, within the limitations of this study is the evidence to ascertain the long-term viability of PEEK-based dental prostheses. Future studies should focus on conducting large-scale, multicenter trials to compare the survival rate of PEEK prostheses to that of conventionally available prosthodontic appliances.
Collapse
Affiliation(s)
- Zohaib Khurshid
- Department of Prosthodontics and Dental Implantology, College of Dentistry, King Faisal University, Al-Ahsa 31982, Saudi Arabia; (B.M.N.); (R.M.M.A.)
- Correspondence:
| | - Binoy Mathews Nedumgottil
- Department of Prosthodontics and Dental Implantology, College of Dentistry, King Faisal University, Al-Ahsa 31982, Saudi Arabia; (B.M.N.); (R.M.M.A.)
| | - Ramy Moustafa Moustafa Ali
- Department of Prosthodontics and Dental Implantology, College of Dentistry, King Faisal University, Al-Ahsa 31982, Saudi Arabia; (B.M.N.); (R.M.M.A.)
- Department of Removable Prosthodontics, Faculty of Dentistry, Fayoum University, Fayoum 2933110, Egypt
| | - Sompop Bencharit
- VCU Philips Institute for Oral Health Research, Department of Biomedical Engineering, School of Dentistry, College of Engineering, Virginia Commonwealth University, Richmond, VA 23298, USA;
| | - Shariq Najeeb
- Schulich School of Medicine and Dentistry, University of Western Ontario, London, ON N6A 3K7, Canada;
| |
Collapse
|
11
|
Zhang X, Wang Z, Yao S, Zhou C, Wu J. Development and Dental Applications of Spiro Expanding Monomers as Antishrinkage Additives. ChemistrySelect 2022. [DOI: 10.1002/slct.202201025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Xiaoran Zhang
- Department of Prosthodontics School and Hospital of Stomatology, Cheeloo College of Medicine Shandong University Shandong Key Laboratory of Oral Tissue Regeneration Shandong Engineering Laboratory for Dental Materials and Oral Tissue Regeneration Jinan 250012 China
| | - Zonghua Wang
- Department of Prosthodontics School and Hospital of Stomatology, Cheeloo College of Medicine Shandong University Shandong Key Laboratory of Oral Tissue Regeneration Shandong Engineering Laboratory for Dental Materials and Oral Tissue Regeneration Jinan 250012 China
| | - Shuo Yao
- Department of Prosthodontics School and Hospital of Stomatology, Cheeloo College of Medicine Shandong University Shandong Key Laboratory of Oral Tissue Regeneration Shandong Engineering Laboratory for Dental Materials and Oral Tissue Regeneration Jinan 250012 China
| | - Chuanjian Zhou
- Research Institute of Polymer Materials School of Materials Science and Engineering Shandong University Jinan 250061 China
| | - Junling Wu
- Department of Prosthodontics School and Hospital of Stomatology, Cheeloo College of Medicine Shandong University Shandong Key Laboratory of Oral Tissue Regeneration Shandong Engineering Laboratory for Dental Materials and Oral Tissue Regeneration Jinan 250012 China
| |
Collapse
|
12
|
In Vitro Analysis of the Mechanical Properties of Hypoallergenic Denture Base Resins. MATERIALS 2022; 15:ma15103611. [PMID: 35629638 PMCID: PMC9147828 DOI: 10.3390/ma15103611] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 05/11/2022] [Accepted: 05/16/2022] [Indexed: 02/05/2023]
Abstract
The development of hypoallergenic denture resins is key to the treatment of patients with allergies to polymethyl methacrylate (PMMA). In this study, the in vitro mechanical properties of hypoallergenic and PMMA denture base resins were compared. Ninety-six test specimens of hypoallergenic denture base resins (Polyan Plus®, Sinomer, TMS Acetal Dental, Erkocryl) and 72 test specimens of PMMA-based denture base resins (Paladon 65, PalaXpress, SR-Ivocap) were fabricated. The flexural strength, elastic modulus, compressive strength, macro- and microhardness, average roughness, water absorption, and water solubility of the resins were measured. None of the hypoallergenic denture resins matched all the mechanical properties of the PMMA resins. Polyan Plus® and TMS Acetal Dental were closest to matching the mechanical properties of the PMMA resins, and TMS Acetal Dental had some superior properties. Consequently, Polyan Plus® and TMS Acetal Dental hypoallergenic resins are recommended for further investigation as potential alternatives to PMMA resins for the fabrication of removable dentures.
Collapse
|
13
|
Comparison between Conventional PMMA and 3D Printed Resins for Denture Bases: A Narrative Review. JOURNAL OF COMPOSITES SCIENCE 2022. [DOI: 10.3390/jcs6030087] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
The aim of the current paper is to review the available literature reporting on comparative studies of heat-cured resins and three-dimensionally printed biomaterials for denture bases in terms of their composition, properties, fabrication techniques and clinical performance. The methodology included applying a search strategy, defining inclusion and exclusion criteria, selecting studies to summarize the results. Searches of PubMed, Scopus, and Embase databases were performed independently by three reviewers to gather literature published between 2018 and 2021. A total of 135 titles were obtained from the electronic databases, and the application of exclusion criteria resulted in the identification of 42 articles pertaining to conventional and 3D printed technology for removable dentures. The main disadvantages of the heat-cured resins for removable dentures are that they require lots of special equipment, skilled personnel and time. Emerging technologies, such as 3D printed dentures, have the potential to alleviate these problems allowing for faster patient rehabilitation. With the development of digital dentistry, it is becoming increasingly necessary to use 3D printed resin materials for the manufacturing of removable dentures. However, further research is required on the existing and developing materials to allow for advancement and increase its application in removable prosthodontics.
Collapse
|
14
|
Is the Number of Appointments for Complete Denture Fabrication Reduced with CAD-CAM? A Literature Review. PROSTHESIS 2022. [DOI: 10.3390/prosthesis4010010] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
One of the key arguments in favor of digitally produced complete dentures (CDs) is the requirement for less patient visits in comparison to the conventional workflow. However, it is not yet clear if this argument is accurate; nor, if indeed the insertion of the complete dentures is achieved in fewer appointments, how many are required. The purpose of this literature review was to investigate the reported number of required patient visits for the production of digitally fabricated CDs. An electronic search was performed in PubMed/MEDLINE using three groups of keywords: “complete dentures”, “CAD/CAM”, and “Appointments” with their alternative forms. Out of the initial 157 results, 36 articles were automatically selected utilizing exclusion keywords. After consensus between the two examiners, eight articles were finally analyzed and presented in a table. The majority (75%) of the reports came from institutions, and the average number of appointments up to complete denture insertion was 4.1, not always including try-in dentures. In this study, it can be concluded that, with a digital workflow, the insertion appointment is reached in fewer visits than the conventional five-visit procedure which is commonly taught in dental schools.
Collapse
|
15
|
Abualsaud R, Gad M. Flexural strength of CAD/CAM denture base materials: Systematic review and meta-analysis of in-vitro studies. J Int Soc Prev Community Dent 2022; 12:160-170. [PMID: 35462750 PMCID: PMC9022382 DOI: 10.4103/jispcd.jispcd_310_21] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 12/11/2021] [Accepted: 12/22/2021] [Indexed: 11/25/2022] Open
Abstract
Introduction: Digital complete dentures fabrication techniques are expanding. This study aimed to review flexural strength (FS) of milled and 3D-printed denture base materials to answer the study question: is FS of computer-aided designing/computer-aided manufacturing (CAD/CAM) denture base comparable to conventional heat-polymerized materials? Materials and Methods: Search was done within different databases for articles published between January 2010 and June 2021 using specific keywords. Articles of in-vitro studies in English language with methods following International Standards Organization standardization/ADA specifications for flexural testing of conventional and CAD/CAM (milled or printed) polymethyl methacrylate (PMMA) materials were included. Results: Out of the 61 studies, 9 were processed for data extraction and only 7 underwent meta-analysis. Two, six, and one study showed high, moderate, and low risk of bias, respectively. Random-effects model was used for analysis and resulted in the average FS of 120.61 MPa [95% confidence interval (CI): 109.81−131.41] and 92.16 MPa (CI: 75.12−109.19) for CAD/CAM milled and heat-polymerized PMMA, respectively. Conclusion: Subtractive CAD/CAM technique of denture fabrication showed satisfactory FS values, whereas additive CAD/CAM method was comparable to conventional heat-polymerized technique with lower value, requiring further investigations and improvement. The clinical use of milled denture bases is an acceptable substitution to heat-polymerized PMMA, making the denture fabrication an easier and faster process.
Collapse
|
16
|
Alhotan A, Yates J, Zidan S, Haider J, Jurado CA, Silikas N. Behaviour of PMMA Resin Composites Incorporated with Nanoparticles or Fibre following Prolonged Water Storage. NANOMATERIALS 2021; 11:nano11123453. [PMID: 34947803 PMCID: PMC8707186 DOI: 10.3390/nano11123453] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Accepted: 12/15/2021] [Indexed: 11/25/2022]
Abstract
When PMMA denture base acrylics are exposed to oral environments for prolonged periods, the denture base absorbs water, which has a negative influence on the denture material and the degree to which the denture base will be clinically effective. This study assessed the water sorption, desorption, and hygroscopic expansion processes within PMMA denture-base resins reinforced with nanoparticles or fibre in comparison to the non-reinforced PMMA. The surfaces of the fillers were modified using a silane coupling agent (y-MPS) before mixing with PMMA. Group C consisted of specimens of pure PMMA whereas groups Z, T, and E consisted of PMMA specimens reinforced with ZrO2, TiO2 nanoparticles, or E-glass fibre, respectively. The reinforced groups were subdivided into four subgroups according to the percentage filler added to the PMMA resin by weight (1.5%, 3.0%, 5.0%, or 7.0%). Five specimens in disc shape (25 ± 1 mm × 2.0 ± 0.2 mm) were tested for each group. To assess water sorption and hygroscopic expansion, specimens from each group were individually immersed in water at 37 ± 1 °C for 180 days. The samples were then desorbed for 28 days at 37 ± 1 °C, to measure solubility. Water sorption and solubility were calculated using an electronic balance in accordance with ISO Standard 20795-1, and hygroscopic expansion was measured using a laser micrometre. Statistical analysis was undertaken at a p ≤ 0.05 significance level using a one-way ANOVA followed by Tukey post-hoc tests. The results demonstrated that the values of sorption (Wsp), mass sorption (Ms%), and % expansion within the tested groups reached equilibrium within 180 days. A noticeable difference was observed in groups Z and E for (Wsp)/(Ms%) compared to the Group C, but this was not significant. However, the difference between Group C and Group T for these measurements was significant. Non-significant differences also existed between each respective reinforced group and the control group in terms of hygroscopic expansion % values. During the 28-day desorption period, there were no differences in the values of solubility (Wsl)/mass desorption (Md%) between Group C and each of the reinforced tested groups. The findings indicate that the inclusion of ZrO2 nanoparticles or E-glass fibres does not increase the water solubility/sorption of the PMMA. However, modifying the PMMA with TiO2 did significantly increase the water sorption level.
Collapse
Affiliation(s)
- Abdulaziz Alhotan
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK; (J.Y.); (J.H.); (N.S.)
- Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh 11454, Saudi Arabia
- Correspondence:
| | - Julian Yates
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK; (J.Y.); (J.H.); (N.S.)
| | - Saleh Zidan
- Department of Dental Materials, Faculty of Dentistry, Sebha University, Sebha 18758, Libya;
| | - Julfikar Haider
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK; (J.Y.); (J.H.); (N.S.)
- Department of Engineering, Manchester Metropolitan University, Manchester M1 5GD, UK
| | - Carlos Alberto Jurado
- Woody L. Hunt School of Dental Medicine, Texas Tech University Health Sciences Centre El Paso, 5001 El Paso Drive, El Paso, TX 79905, USA;
| | - Nikolaos Silikas
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK; (J.Y.); (J.H.); (N.S.)
| |
Collapse
|
17
|
Di Fiore A, Meneghello R, Brun P, Rosso S, Gattazzo A, Stellini E, Yilmaz B. Comparison of the flexural and surface properties of milled, 3D-printed, and heat polymerized PMMA resins for denture bases: an in vitro study. J Prosthodont Res 2021; 66:502-508. [PMID: 34853238 DOI: 10.2186/jpr.jpr_d_21_00116] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To compare the flexural properties and the adhesion of Lactobacillus salivarius (LS), Streptococcus mutans (SM), and Candida albicans (CA) on heat-polymerized (CV), CAD-CAM milled (CAD), or 3D-printed (3D) Poly (methylmethacrylate) (PMMA). METHODS Ultimate Flexural Strength (UFS), Flexural Strain (FS) (%) at Flexural Strength, and Flexural Modulus (FM) of specimens (65.0×10.0×3.3 mm) from each PMMA group (n=6) were calculated by using the 3-point bending test. The surface roughness profiles (R) were measured before and after polishing with a contact profilometer. LS, SM, and CA adhesion on PMMA specimens (n=18) (10 mm in diameter, 3 mm in height) was assessed after 90 minutes and 16 hours by using scanning electron microscopy. The Kruskal-Wallis test with post hoc analysis was performed to compare the groups (alpha=0.05). RESULTS Mean UFS values were 80.79±7.64 MPa for CV, 110.23±5.03 MPa for CAD, and 87.34±6.39 MPa for 3D. Mean FS values were 4.37±1.04% for CV, 4.71±0.62% for CAD, and 6.19±0.13 % for 3D. Mean FM values were 2542±301 MPa for CV, 3435±346 MPa for CAD, and 2371±197 MPa for 3D. CAD had the lowest average R value (0.29±0.16 µm) before polishing, and bacterial adhesion after 90 minutes of incubation. R value and microbial adhesion were not different amongst groups after polishing and 16 hours of incubation, respectively. CONCLUSION The CAD group displayed the best flexural properties, except for FS, the lowest roughness before polishing and bacterial adhesion after 90 minutes of incubation. All tested PMMAs had similar surface roughness after polishing, and microbial adhesion after 16 hours of incubation.
Collapse
Affiliation(s)
- Adolfo Di Fiore
- Department of Neurosciences, School of Dentistry, Section of Prosthodontics and Digital Dentistry, University of Padova, Padova, Italy
| | | | - Paola Brun
- Department of Molecular Medicine, University of Padova, Padova, Italy
| | - Stefano Rosso
- Department of Management and Engineering, University of Padova, Italy
| | | | - Edoardo Stellini
- Head of University Dental Clinic, Department of Neurosciences, School of Dentistry, University of Padova, Italy
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland.,Division of Restorative and Prosthetic Dentistry, The Ohio State University, Ohio, USA
| |
Collapse
|
18
|
Shin SH, Doh RM, Lim JH, Kwon JS, Shim JS, Kim JE. Evaluation of Dimensional Changes According to Aging Period and Postcuring Time of 3D-Printed Denture Base Prostheses: An In Vitro Study. MATERIALS 2021; 14:ma14206185. [PMID: 34683773 PMCID: PMC8539717 DOI: 10.3390/ma14206185] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 10/14/2021] [Accepted: 10/16/2021] [Indexed: 11/16/2022]
Abstract
During the three-dimensional (3D) printing process of a dental prosthesis, using photopolymer resin, partially polymerized resin is further cured through the postcuring process that proceeds after the printing, which improves the stability of the printed product. The mechanical properties of the end product are known to be poor if the postcuring time is insufficient. Therefore, this study evaluated the effect of the postcuring time of the 3D-printed denture base on its dimensional stability, according to the aging period. The 3D prints were processed after designing maxillary and mandibular denture bases, and after the following postcuring times were applied: no postcuring, and 5, 15, 30, and 60 min. The dimensional stability change of the denture base was evaluated and analyzed for 28 days after the postcuring process. The trueness analysis indicated that the mandibular denture base had lower output accuracy than the maxillary denture base, and the dimensional stability change increased as postcuring progressed. In the no postcuring group for the mandible, the error value was 201.1 ± 5.5 µm (mean ± standard deviation) after 28 days, whereas it was 125.7 ± 13.0 µm in the 60 min postcuring group. For both the maxilla and the mandible, shorter postcuring times induced larger dimensional stability changes during the aging process. These findings indicate that in order to manufacture a denture base with dimensional stability, a sufficient postcuring process is required during the processing stage.
Collapse
Affiliation(s)
- Seung-Ho Shin
- BK21 FOUR Project, Oral Research Science Center, Department of Prosthodontics, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seoul 03722, Korea; (S.-H.S.); (J.-H.L.)
| | - Re-Mee Doh
- Department of Advanced General Dentistry, College of Dentistry, Dankook University, Cheonan 31116, Korea;
| | - Jung-Hwa Lim
- BK21 FOUR Project, Oral Research Science Center, Department of Prosthodontics, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seoul 03722, Korea; (S.-H.S.); (J.-H.L.)
| | - Jae-Sung Kwon
- Department and Research Institute of Dental Biomaterials and Bioengineering, Yonsei University College of Dentistry, Seoul 03722, Korea;
| | - June-Sung Shim
- Department of Prosthodontics, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seoul 03722, Korea;
| | - Jong-Eun Kim
- Department of Prosthodontics, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seoul 03722, Korea;
- Correspondence: ; Tel.: +82-2-2228-3166
| |
Collapse
|
19
|
Ajay R, Rakshagan V, Ganeshkumar R, Ambedkar E, RahmathShameem S, Praveena K. Synthesis and Characterization of a Ring-Opening Oxaspiro Comonomer by a Novel Catalytic Method for Denture Base Resins. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES 2021; 13:S521-S526. [PMID: 34447146 PMCID: PMC8375839 DOI: 10.4103/jpbs.jpbs_524_20] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 10/15/2020] [Accepted: 11/24/2020] [Indexed: 11/22/2022] Open
Abstract
Background: 3,9-Dimethylene-1,5,7,11-tetraoxaspiro[5,5]undecane (DMTOSU) is a double ring-opening monomer that exhibits expansion upon polymerization and may be used as a denture base resin's comonomer to offset or minimize polymerization shrinkage. It's synthesis by transesterification reaction (TE) catalyzed by distannoxane is not reported in the literature. The synthesis became the prime concern because this monomer is hardly available commercially. Purpose: The purpose is to confirm the DMTOSU synthesis and compare the synthesized monomers obtained by two different catalytic processes through Fourier transform infrared (FTIR) and nuclear magnetic resonance (NMR) spectroscopies. Materials and Methods: Scheme I synthesis was by TE catalyzed by dichlorotetrabutyl distannoxane (DCBS) yielding M1 monomer. Scheme II synthesis was catalyzed by dibutyltin oxide-carbon disulfide (DBTO-CS2) yielding M2 monomer. Results: The appearance of a characteristic peak at 1212 cm−1 in FTIR spectrum, a doublet at δ 4.95 in 1H-NMR spectrum and a peak at δ 117.12 in 13C-NMR spectrum confirmed the synthesis of DMTOSU-M1catalyzed by DCBS, which is not significantly different from DMTOSU-M2 catalyzed by DBTO-CS2. Conclusion: The catalytic action of DCBS is a successful alternative to the DBTO-CS2 catalysis in DMTOSU synthesis.
Collapse
Affiliation(s)
- Ranganathan Ajay
- Department of Prosthodontics and Crown and Bridge, Vivekanandha Dental College for Women, Namakkal, Tamil Nadu, India
| | - Vikraman Rakshagan
- Department of Prosthodontics and Implant Dentistry, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Science, Saveetha University, Chennai, Tamil Nadu, India
| | - Rajamani Ganeshkumar
- Department of Prosthodontics and Crown and Bridge, Sri Venkateswara Dental College and Hospital, Chennai, Tamil Nadu, India
| | - Elumalai Ambedkar
- Department of Prosthodontics and Crown and Bridge, Sri Venkateswara Dental College and Hospital, Chennai, Tamil Nadu, India
| | - Shafiullah RahmathShameem
- Department of Prosthodontics and Crown and Bridge, Sri Venkateswara Dental College and Hospital, Chennai, Tamil Nadu, India
| | - Kanagesan Praveena
- Department of Prosthodontics and Crown and Bridge, JKK Nattraja Dental College and Hospital, Komarapalayam, Tamil Nadu, India
| |
Collapse
|
20
|
Ajay R, Rakshagan V, Sreevarun M, Bhuvaneshkumar D, SajidaBegum S, Vignesh V. Copolymerization of Ring-Opening Oxaspiro Comonomer with Denture Base Acrylic Resin by Free-Radical/Cationic Hybrid Polymerization. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES 2021; 13:S527-S531. [PMID: 34447147 PMCID: PMC8375785 DOI: 10.4103/jpbs.jpbs_582_20] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 10/12/2020] [Accepted: 11/24/2020] [Indexed: 11/04/2022] Open
Abstract
BACKGROUND Polymerization shrinkage is an innate characteristic of thermo-polymerized denture base acrylic resin. Volumetric shrinkage is still a problem, although myriad material modifications. Ring-opening oxaspiro monomers have promising volumetric expansions of about 7%. These monomers have diminished the shrinkage in dental filling resins through copolymerization (CP). However, their CP with denture base resins is not reported yet. PURPOSE The aim is to confirm the CP of an oxaspiro monomer with methyl methacrylate (MMA) by radical-cationic hybrid polymerization and to assess the degree of conversion (DC) of the formed copolymer. MATERIALS AND METHODS The oxaspiro monomer was synthesized by a transesterification reaction. The study groups were based on the composition and thermo-polymerization method. The control and E1 groups were thermo-polymerized in water-bath, whereas the E2 group in a laboratory autoclave. Both E1 and E2 groups contained the oxaspiro monomer and cationic initiator. E2 group had an additional radical initiator. The CP and DC were confirmed and assessed by infrared spectroscopy. RESULTS Accentuation of carbonyl peak, the disappearance of the spiro-carbon peak, and the appearance of ether linkages in experimental groups confirmed the ring-opening. E2 group had the highest DC. CONCLUSION The oxaspiro monomer successfully copolymerized with MMA and had good DC.
Collapse
Affiliation(s)
- Ranganathan Ajay
- Department of Prosthodontics and Crown and Bridge, Vivekanandha Dental College for Women, Namakkal, Tamil Nadu, India
| | - Vikraman Rakshagan
- Department of Prosthodontics and Implant Dentistry, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Science, Saveetha University, Chennai, Tamil Nadu, India
| | - Murugesan Sreevarun
- Department of Prosthodontics and Crown and Bridge, Best Dental Science College and Hospital, Madurai, Tamil Nadu, India
| | - Dharanividhya Bhuvaneshkumar
- Department of Prosthodontics and Crown and Bridge, Vinayaka Missions Sankarachariyar Dental College and Hospital, Salem, Tamil Nadu, India
| | - Sekaran SajidaBegum
- Department of Prosthodontics and Crown and Bridge, Vinayaka Missions Sankarachariyar Dental College and Hospital, Salem, Tamil Nadu, India
| | - Veerakumar Vignesh
- Department of Prosthodontics and Crown and Bridge, Vinayaka Missions Sankarachariyar Dental College and Hospital, Salem, Tamil Nadu, India
| |
Collapse
|
21
|
Baba NZ, Goodacre BJ, Goodacre CJ, Müller F, Wagner S. CAD/CAM Complete Denture Systems and Physical Properties: A Review of the Literature. J Prosthodont 2021; 30:113-124. [DOI: 10.1111/jopr.13243] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/23/2020] [Indexed: 11/28/2022] Open
Affiliation(s)
- Nadim Z. Baba
- Advanced Education Program in Implant Dentistry Loma Linda University School of Dentistry Loma Linda CA
| | - Brian J. Goodacre
- Division of General Dentistry Loma Linda University School of Dentistry Loma Linda CA
| | - Charles J. Goodacre
- Advanced Education in Implant Dentistry Loma Linda University School of Dentistry Loma Linda CA
| | - Frauke Müller
- Clinique Universitaire de Médecine Dentaire, Division de Gérodontologie et Prothèse adjointe Université de Genève Switzerland
| | | |
Collapse
|
22
|
Oğuz Eİ, Kılıçarslan MA, Özcan M, Ocak M, Bilecenoğlu B, Orhan K. Evaluation of Denture Base Adaptation Fabricated Using Conventional, Subtractive, and Additive Technologies: A Volumetric Micro‐Computed Tomography Analysis. J Prosthodont 2021; 30:257-263. [DOI: 10.1111/jopr.13326] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/21/2020] [Indexed: 11/26/2022] Open
Affiliation(s)
- Ece İrem Oğuz
- Department of Prosthodontics Faculty of Dentistry Ankara University Ankara Turkey
| | | | - Mutlu Özcan
- Center for Dental and Oral Medicine University of Zürich Zürich Switzerland
| | - Mert Ocak
- Department of Anatomy Faculty of Dentistry Ankara University Ankara Turkey
| | - Burak Bilecenoğlu
- Department of Anatomy Faculty of Medicine Medipol University Ankara Turkey
| | - Kaan Orhan
- Department of Dentomaxillofacial Radiology Faculty of Dentistry Ankara University Ankara Turkey
| |
Collapse
|
23
|
Perea-Lowery L, Minja IK, Lassila L, Ramakrishnaiah R, Vallittu PK. Assessment of CAD-CAM polymers for digitally fabricated complete dentures. J Prosthet Dent 2021; 125:175-181. [DOI: 10.1016/j.prosdent.2019.12.008] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Revised: 12/11/2019] [Accepted: 12/11/2019] [Indexed: 10/25/2022]
|
24
|
Zidan S, Silikas N, Haider J, Yates J. Long-Term Sorption and Solubility of Zirconia-Impregnated PMMA Nanocomposite in Water and Artificial Saliva. MATERIALS 2020; 13:ma13173732. [PMID: 32847026 PMCID: PMC7503455 DOI: 10.3390/ma13173732] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Revised: 08/17/2020] [Accepted: 08/20/2020] [Indexed: 11/30/2022]
Abstract
Exposure of denture base acrylic resins to the oral environment and storage media for extended periods of time results in sorption of saliva or water, leading to a reduction in physical properties and thus clinical service life. The purpose of this in vitro study was to assess the sorption and solubility of high-impact heat-polymerised denture base acrylic resin (HI PMMA) impregnated with zirconia nanoparticles after being stored for 180 days in distilled water (DW) and artificial saliva (AS). The specimens were divided into six groups for each storage medium, according to the concentration of zirconia nanoparticles (0, 1.5, 3.0, 5.0, 7.0, and 10.0 wt.%). Data were statistically analysed for sorption and solubility using one-way and two-way ANOVA statistical tests. Sorption in DW and AS for all groups containing zirconia showed sorption values lower than the control group at 90 days, though not significantly different (p > 0.05) compared to the control group. For both the DW and AS groups, the lowest solubility value was measured in the group containing 3 wt.% zirconia, however, there was no significant difference compared to the control group except when observing 10 wt.% zirconia in AS, which showed a significantly higher solubility (p < 0.05). High-impact PMMA, impregnated with low concentrations of ZrO2, showed the lowest sorption and solubility in both media, but was not significantly different compared to pure HI PMMA.
Collapse
Affiliation(s)
- Saleh Zidan
- Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK; (N.S.); (J.Y.)
- Department of Dental Materials, Faculty of Dentistry, Sebha University, Sebha, Libya
- Correspondence: or ; Tel.: +44-79-3309-6536
| | - Nikolaos Silikas
- Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK; (N.S.); (J.Y.)
| | - Julfikar Haider
- Department of Engineering, Manchester Metropolitan University, Manchester M1 5GD, UK;
| | - Julian Yates
- Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK; (N.S.); (J.Y.)
| |
Collapse
|
25
|
Azevedo L, Antonaya-Martin JL, Molinero-Mourelle P, Del Río-Highsmith J. Improving PMMA resin using graphene oxide for a definitive prosthodontic rehabilitation - A clinical report. J Clin Exp Dent 2019; 11:e670-e674. [PMID: 31516667 PMCID: PMC6730997 DOI: 10.4317/jced.55883] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2019] [Accepted: 06/12/2019] [Indexed: 11/06/2022] Open
Abstract
The use of acrylic resins as a definitive material has shown some advantages comparing to other definitive materials. However, their poor mechanical properties remain a major drawback. In this case report, graphene oxide (GO) was incorporated into polymethyl methacrylate (PMMA) resin for a definitive maxillary rehabilitation, combined with an intraoral digital impression and a three-dimensional facial scan. After 8 months of the placement of the definitive prosthesis, no mechanical, aesthetic, or biologic complications were reported, and the soft tissues showed excellent health and stability. The incorporation of GO in PMMA resins seems to be a suitable option for prosthetic rehabilitation. However, further studies are needed to ensure rigorous scientific support of these techniques and materials.
Key words:Computer-aided design, computer-aided manufacturing, dental impression technique, dental prosthesis; graphene oxide.
Collapse
Affiliation(s)
- Luís Azevedo
- DDS. Postgraduate student, Department of Conservative Dentistry and Orofacial Prosthodontics. School of Dentistry. Complutense University of Madrid, Madrid, Spain
| | - José L Antonaya-Martin
- DDS, PhD. Clinical Assistant Professor, Department of Conservative Dentistry and Orofacial Prosthodontics. School of Dentistry. Complutense University of Madrid, Madrid, Spain
| | - Pedro Molinero-Mourelle
- DDS, MDS. PhD student, Department of Conservative Dentistry and Orofacial Prosthodontics. School of Dentistry. Complutense University of Madrid, Madrid, Spain
| | - Jaime Del Río-Highsmith
- MD, DDS, PhD. Professor, Department of Conservative Dentistry and Orofacial Prosthodontics. School of Dentistry. Complutense University of Madrid, Madrid, Spain
| |
Collapse
|
26
|
Zirak M, Vojdani M, Mohammadi S, Khaledi AA. Comparison of the Water Sorption and Solubility of Four Reline Acrylic Resins after Immersion in Food-Simulating Agents. J Int Soc Prev Community Dent 2019; 9:40-46. [PMID: 30923692 PMCID: PMC6402257 DOI: 10.4103/jispcd.jispcd_296_18] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2018] [Accepted: 11/30/2018] [Indexed: 11/04/2022] Open
Abstract
Objectives Water sorption and water solubility adversely affect the mechanical properties and biocompatibility of the denture material. This study aimed to evaluate the water sorption and solubility of three direct hard reline acrylic resins and a heat-curing one after immersion in food-simulating agents. Materials and Methods This study was performed on four groups of samples (n = 10 per group). The samples were made of three direct hard reline acrylic resins (TDV Cold Liner Rebase, Tokuyama Rebase II Fast, GC Reline Hard) and a heat-curing one (Meliodent). Each group was divided into four subgroups (n = 10) to undergo 7-day immersion in distilled water, 75% ethanol/water, 0.02 N citric acid, and heptane. Water sorption and solubility were calculated according to Oysaed and Ruyter formula. The statistical analyses were done by using SPSS software (version 22). Kruskal-Wallis H Test and Dunn's test were used to detect any significant difference among the groups (P < 0.05). Results The median range of water solubility and water sorption values were -0.87-4.92 and 3.75-27.25 μg/mm3, respectively. The median solubility and sorption values of different resins differed significantly in the same solution (P < 0.05). Besides, immersion in different solutions caused significant differences in the median solubility and sorption values of each reline material (P < 0.05), except for Meliodent whose solubility was not significantly affected by different solutions (P = 0.16). Conclusions Water sorption and solubility values of the tested hard reline resins were within the range of International Standards Organization 1567:1999. Given the low sorption and solubility values, these hard reline materials can be safely used in clinical situations.
Collapse
Affiliation(s)
- Mitra Zirak
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mahroo Vojdani
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Sorour Mohammadi
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Amir-Alireza Khaledi
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
27
|
Gopalakrishnan S, Raj I, Mathew T. A, Abraham J, Maria HJ, Mozetič M, Thomas S, Kalarikkal N. Development of oral‐fluid‐impervious and fracture‐resistant silver–poly(methyl methacrylate) nanoformulations for intra‐oral/extra‐oral rehabilitation. J Appl Polym Sci 2019. [DOI: 10.1002/app.47669] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Sandhya Gopalakrishnan
- International and Inter University Centre for Nanoscience and Nanotechnology, Mahatma Gandhi University Kottayam 686 560 Kerala India
- Department of ProsthodonticsGovernment Dental College Gandhinagar Post Office, Kottayam 686 008 Kerala India
| | - Indu Raj
- International and Inter University Centre for Nanoscience and Nanotechnology, Mahatma Gandhi University Kottayam 686 560 Kerala India
- Department of ProsthodonticsGovernment Dental College Gandhinagar Post Office, Kottayam 686 008 Kerala India
| | - Aby Mathew T.
- Department of ProsthodonticsPushpagiri College of Dental Sciences Pushpagiri Medicity, Perumthuruthy, 686 548 Kerala India
| | - Jiji Abraham
- International and Inter University Centre for Nanoscience and Nanotechnology, Mahatma Gandhi University Kottayam 686 560 Kerala India
- School of Chemical Sciences, Mahatma Gandhi University Kottayam 686 560 Kerala India
| | - Hanna. J. Maria
- International and Inter University Centre for Nanoscience and Nanotechnology, Mahatma Gandhi University Kottayam 686 560 Kerala India
- School of Chemical Sciences, Mahatma Gandhi University Kottayam 686 560 Kerala India
| | - Miran Mozetič
- Jozef Stefan Institute Jamova 39, Ljubljana 1000 Slovenia
| | - Sabu Thomas
- International and Inter University Centre for Nanoscience and Nanotechnology, Mahatma Gandhi University Kottayam 686 560 Kerala India
- School of Chemical Sciences, Mahatma Gandhi University Kottayam 686 560 Kerala India
| | - Nandakumar Kalarikkal
- International and Inter University Centre for Nanoscience and Nanotechnology, Mahatma Gandhi University Kottayam 686 560 Kerala India
- School of Pure and Applied Physics, Mahatma Gandhi University Kottayam 686 560 Kerala India
| |
Collapse
|
28
|
Srinivasan M, Gjengedal H, Cattani-Lorente M, Moussa M, Durual S, Schimmel M, Müller F. CAD/CAM milled complete removable dental prostheses: An in vitro evaluation of biocompatibility, mechanical properties, and surface roughness. Dent Mater J 2018. [PMID: 29515054 DOI: 10.4012/dmj.2017-207] [Citation(s) in RCA: 78] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study compared the biocompatibility, mechanical properties, and surface roughness of a pre-polymerized polymethyl methacrylate (PMMA) resin for CAD/CAM complete removable dental prostheses (CRDPs) and a traditional heat-polymerized PMMA resin. Two groups of resin substrates [Control (RC): conventional PMMA; Test (RA): CAD/CAM PMMA] were fabricated. Human primary osteoblasts and mouse embryonic-fibroblasts were cultured for biocompatibility assays. Mechanical properties and surface roughness were compared. ANOVA revealed no difference between the resin groups in the biocompatibility assays. RA demonstrated a higher elastic modulus (p=0.002), young's modulus (p=0.002), plastic energy (p=0.002), ultimate strength (p=0.0004), yield point (p=0.016), strain at yield point (p=0.037), and toughness (p<0.0001); while RC displayed a higher elastic energy (p<0.0001). Laser profilometry concluded a rougher surface profile (p<0.0001) for RA. This study concluded that the tested CAD/CAM resin was equally biocompatible and presented with improved mechanical properties than the traditional heat-polymerized PMMA resin used in the fabrication of CRDPs.
Collapse
Affiliation(s)
- Murali Srinivasan
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva
| | | | - Maria Cattani-Lorente
- Department of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva
| | - Mira Moussa
- Department of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva
| | - Stéphane Durual
- Department of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva
| | - Martin Schimmel
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva.,Division of Gerodontology, School of Dental Medicine, University of Bern
| | - Frauke Müller
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva.,Service of Geriatrics, Department of Internal Medicine, Rehabilitation and Geriatrics, University Hospitals of Geneva
| |
Collapse
|
29
|
Sayed ME, Porwal A, Ehrenberg D, Weiner S. Effect of Cast Modification on Denture Base Adaptation Following Maxillary Complete Denture Processing. J Prosthodont 2017; 28:e6-e12. [PMID: 28102940 DOI: 10.1111/jopr.12594] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/09/2016] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To investigate the effect of cast modifications on denture base adaptation in coronal and sagittal projections following maxillary complete denture processing. MATERIALS AND METHODS A total of 60 edentulous maxillary casts (n = 10) were distributed among six groups. Group 1 was the control group with no modification, groups 2 through 6 included a butterfly postdam preparation, groups 3 and 4 also included a 10-mm wide/4-mm deep box with addition of four round holes in group 4, and groups 5 and 6 also included a 20-mm wide/4-mm deep box with addition of four round holes in group 6. The boxes were prepared at the mid-heel area of the casts. Two layers of baseplate wax (1 mm each) were used to standardize denture base thickness across the groups. A standard technique was used to replicate the denture tooth set-up, and standardized processing was done for all the groups. Following deflasking, casts with the dentures were sectioned in the coronal and sagittal directions. Microscopic pictures were taken at preselected points. Data were organized in tables, and statistical analyses were performed using repeated measure ANOVA, Tukey post hoc tests, and post hoc comparison tests set at 5% level of significance. RESULTS Maximum gaps were measured at the mid-palatal area followed by nearby areas and the areas near ridge crests in both coronal and sagittal projections. The analyses revealed significant differences between the groups in coronal projection (1/2, 3/4, 5/6) and sagittal projection (1, 2, 3/4, 5/6) without significant differences within the pairs. The groups were ranked from the highest group 1 to the lowest group 6 relative to the gap means. Post hoc comparisons showed that points 1C and 2A had the highest gap means across the study groups. CONCLUSIONS Within the limitations of this study, it can be extrapolated that the denture base adaptation can be effectively increased with the box preparation at the mid-heel aspect of the casts. Significant reduction of gaps was seen when the box size increased from 10 to 20 mm in coronal and sagittal projections; however, the addition of four holes had no significant effect on gap size alterations.
Collapse
Affiliation(s)
- Mohammed E Sayed
- Department of Restorative Dentistry, Rutgers School of Dental Medicine, Newark, NJ.,Department of Prosthetic Dental Sciences, Jazan University College of Dentistry, Jazan, Saudi Arabia
| | - Amit Porwal
- Department of Prosthetic Dental Sciences, Jazan University College of Dentistry, Jazan, Saudi Arabia
| | - David Ehrenberg
- Department of Restorative Dentistry, Rutgers School of Dental Medicine, Newark, NJ
| | - Saul Weiner
- Department of Restorative Dentistry, Rutgers School of Dental Medicine, Newark, NJ
| |
Collapse
|
30
|
Srinivasan M, Cantin Y, Mehl A, Gjengedal H, Müller F, Schimmel M. CAD/CAM milled removable complete dentures: an in vitro evaluation of trueness. Clin Oral Investig 2016; 21:2007-2019. [DOI: 10.1007/s00784-016-1989-7] [Citation(s) in RCA: 62] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2016] [Accepted: 10/24/2016] [Indexed: 11/30/2022]
|
31
|
Neppelenbroek KH, Urban VM, de Oliveira DG, Porto VC, Almilhatti HJ, Campanha NH. Effect of potentially chromogenic beverages on shear bond strength of acrylic denture teeth to heat-polymerized denture base resins. J Indian Prosthodont Soc 2016; 16:271-5. [PMID: 27621547 PMCID: PMC5000564 DOI: 10.4103/0972-4052.179265] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Background: Detachment of denture acrylic resin artificial teeth from denture base resin is one of the most common problems presented by denture wearers. Purpose: This study investigated the shear bond strength (SBS) and fracture type of bonding interface of two commercial acrylic teeth (Vipi Dent Plus e Biolux) to two denture base resins (Vipi Cril e Lucitone 550) after immersion in potentially chromogenic beverages (coffee, cola soft drink, and red wine) or control solution (distilled water). Materials and Methods: Maxillary central incisor acrylic teeth were placed at 45° to denture base resin and submitted to short polymerization cycle according to manufacturers. Specimens were divided according to the combination tooth/resin/solution (n = 8) and submitted to bond strength tests in a universal testing machine MTS-810 (0.5 mm/min). Subsequently, fracture area was analyzed by stereomicroscope at a magnification of ×10 and categorized into adhesive, cohesive, or mixed failure. Results: The bond strength of teeth/denture base resins interface was not significantly affected by tested solutions (P > 0.087), except for Biolux teeth immersed in coffee (P < 0.01). In all conditions, the Vipi Dent Plus teeth showed higher bond strength to Lucitone and Vipi Cril resins when compared to Biolux teeth (P < 0.003). All specimens’ failure modes were cohesive. Conclusions: The SBS of acrylic teeth to denture base resins was not generally influenced by immersion in the tested staining beverages.
Collapse
Affiliation(s)
| | | | - Denise Gusmão de Oliveira
- Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, São Paulo, Brazil
| | - Vinícius Carvalho Porto
- Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, São Paulo, Brazil
| | | | - Nara Hellen Campanha
- Department of Dentistry, Ponta Grossa State University, Ponta Grossa, Paraná, Brazil
| |
Collapse
|
32
|
Lim SR, Lee JS. Three dimensional deformation of dry-stored complete denture base at room temperature. J Adv Prosthodont 2016; 8:296-303. [PMID: 27555899 PMCID: PMC4993843 DOI: 10.4047/jap.2016.8.4.296] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Revised: 05/24/2016] [Accepted: 05/30/2016] [Indexed: 11/08/2022] Open
Abstract
PURPOSE The aim of this study was to evaluate whether there is any typical deformation pattern existing in complete denture when it was dried by using the 3D scanner and surface matching program. MATERIALS AND METHODS A total of 28 denture bases were fabricated with heat curing acrylic resin (each 14 upper and lower denture bases), and 14 denture bases (each 7 upper and lower denture bases) were stored in the water bottle (water stored), and another 14 denture bases were stored in the air (dry stored). Each specimen was scanned at 1st day after deflasking, 14th day after deflasking, and 28th day after deflasking, and digitalized. Three dimensional deformation patterns were acquired by comparison of the data within storage group using surface matching program. For evaluating differences between groups, these data were compared statisticallyusing Kruskal Wallis and Mann Whitney-U test (α=.05). RESULTS When evaluating 3D deformation of denture base, obvious deformations were not found in maxillary and mandibular water storage group. However, in dry stored group, typical deformation pattern was detected as storage time passes. It occurred mostly in first two weeks. Major deformations were found in the bilateral posterior area in both maxillary and mandibular group. In maxillary dry stored group, a statistical significance was found. CONCLUSION It was proved that in both upper and lower denture bases, dry storage caused more dimensional deformation than water storage with typical pattern.
Collapse
Affiliation(s)
- Seo-Ryeon Lim
- Department of Prosthodontics, College of Dentistry, Dankook University, Cheonan, Republic of Korea
| | - Joon-Seok Lee
- Department of Prosthodontics, College of Dentistry, Dankook University, Cheonan, Republic of Korea
| |
Collapse
|
33
|
Rao DC, Kalavathy N, Mohammad HS, Hariprasad A, Kumar CR. Evaluation of the surface roughness of three heat-cured acrylic denture base resins with different conventional lathe polishing techniques: A comparative study. J Indian Prosthodont Soc 2016; 15:374-80. [PMID: 26929542 PMCID: PMC4762348 DOI: 10.4103/0972-4052.164910] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
PURPOSE Surface roughness promotes adhesion and colonization of denture plaque. Therefore, it is important to know the effects of polishing and finishing on the surface roughness of various acrylic resin materials. OBJECTIVES To evaluate and compare the effects of different conventional lathe polishing techniques on heat cured acrylic resins in producing surface roughness. MATERIALS AND METHODS Three different commercially available heat-cured acrylic resin materials namely DPI, Meliodent and Trevalon Hi were selected. 30 Specimens of each acrylic material (30 x 3 = 90, 10 x 60 x 2mm) were prepared and divided into 5 groups, each group consisted of 6 Nos. of specimens per material(6x3=18) and were grouped as Group A(unfinished), Group B (finished), Group C (Polishing Paste), Group D (Polishing Cake) and Group E (Pumice and Gold rouge). The resulted surface roughness (μm) was measured using Perthometer and observed under Scanning Electron Microscope. The values obtained were subjected statistical analyses. RESULTS Among the materials tested, better results were obtained with Trevalon Hi followed by Meliodent and DPI. Among the polishing methods used, superior results were obtained with universal polishing paste followed by polishing cake; Pumice and Gold rouge. Although Pumice and Gold rouge values produced greater roughness value, they were well within the threshold value of 0.2 mm.
Collapse
Affiliation(s)
| | - N Kalavathy
- Department of Prosthodontics, DAPMRV Dental College, Bengaluru, Karnataka, India
| | - H S Mohammad
- Department of Prosthodontics, MR Ambedkar Dental College, Bengaluru, Karnataka, India
| | - A Hariprasad
- Department of Prosthodontics, MR Ambedkar Dental College, Bengaluru, Karnataka, India
| | - C Ravi Kumar
- Department of Prosthodontics, Mamata Dental College, Khammam, Telangana, India
| |
Collapse
|
34
|
NOGUEIRA M, CAETANO CR, CORRER A, CONSANI R, SANTOS MBFD, BACCHI A. Influence of one- or two-stage methods for polymerizing complete dentures on adaptation and teeth movements. REVISTA DE ODONTOLOGIA DA UNESP 2016. [DOI: 10.1590/1807-2577.10815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Abstract Introduction The quality of complete dentures might be influenced by the method of confection. Objective To evaluate the influence of two different methods of processing muco-supported complete dentures on their adaptation and teeth movements. Material and method Denture confection was assigned in two groups (n=10) for upper and lower arches according to polymerization method: 1) conventional one-stage - a wax trial base was made, teeth were arranged and polymerized; 2) two-stage method - the base was waxed and first polymerized. With the denture base polymerized, the teeth were arranged and then, performed the final polymerization. Teeth movements were evaluated in the distances between incisive (I-I), pre-molars (P-P), molars (M-M), left incisor to left molar (LI-LM) and right incisor to right molar (RI-RM). For the adaptation analysis, dentures were cut in three different positions: (A) distal face of canines, (B) mesial face of the first molars, and (C) distal face of second molars. Result Denture bases have shown a significant better adaptation when polymerized in the one-stage procedure for both the upper (p=0.000) and the lower (p=0.000) arches, with region A presenting significant better adaptation than region C. In the upper arch, significant reduction in the distance between I-I was observed in the one-stage technique, while the two-stage technique promoted significant reduction in the RI-RM distance. In the lower arch, one-stage technique promoted significant reduction in the distance for RI-RM and two-stage promoted significant reduction in the LI-LM distance. Conclusion Conventional one-stage method presented the better results for denture adaptation. Both fabrication methods presented some alteration in teeth movements.
Collapse
|
35
|
Salloum AM. Effect of three investing materials on tooth movement during flasking procedure for complete denture construction. Saudi Dent J 2015; 28:56-61. [PMID: 26792971 PMCID: PMC4688437 DOI: 10.1016/j.sdentj.2015.08.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2013] [Revised: 05/05/2015] [Accepted: 08/23/2015] [Indexed: 11/24/2022] Open
Abstract
PROBLEM STATEMENT Tooth movement has been shown to occur during and after the processing of complete dentures. An understanding of this phenomenon may permit one to construct functional complete dentures that require less occlusal adjustment in the articulator and in the patient's mouth. PURPOSE The purpose of this study was to examine the effects of three different investing methods on tooth movement occurring during the processing of simulated maxillary complete dentures. MATERIAL AND METHODS Forty-five similar maxillary dentures were made using heat-polymerized acrylic resin, and assigned randomly to three experimental groups (n = 15 each) according to investing method: plaster-plaster-plaster (P-P-P), plaster-stone-stone (P-S-S), and plaster-mix (P-M). Specimens in all experimental groups were compression molded with denture base resin. Transverse interincisor (I-I) and intermolar (M-M) distances, and anteroposterior incisor-molar (LI-LM and RI-RM) distances, were measured with digital calipers at the wax denture stage (pre-polymerization) and after denture decasting (post-polymerization). Analysis of variance and Tukey's test were used to compare the results. RESULTS M-M, LI-LM, and RI-RM movement was significantly greater in the P-P-P group than in the P-S-S and P-M groups; no significant difference in I-I movement was observed among groups. Transverse movement along M-M and I-I was significantly greater than anteroposterior movement in the P-P-P group; no significant difference among measurements was observed in the other two groups. CONCLUSION The study results indicate that the use of dental stone or a 50:50 mixture of plaster and stone for investing of dentures is an important factor in efforts to control the magnitude of tooth movement.
Collapse
Affiliation(s)
- Alaa'a M Salloum
- Department of Removable Prosthodontics, Faculty of Dental Medicine, Damascus University, Damascus, Syria
| |
Collapse
|
36
|
Jang DE, Lee JY, Jang HS, Lee JJ, Son MK. Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture. J Adv Prosthodont 2015; 7:278-87. [PMID: 26330974 PMCID: PMC4551783 DOI: 10.4047/jap.2015.7.4.278] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2014] [Revised: 02/23/2015] [Accepted: 03/20/2015] [Indexed: 12/03/2022] Open
Abstract
PURPOSE The aim of this study was to compare the color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for the non-metal clasp dentures to those of thermoplastic polyamide and conventional heat-polymerized denture base resins. MATERIALS AND METHODS Three types of denture base resin, which are conventional heat-polymerized acrylic resin (Paladent 20), thermoplastic polyamide resin (Bio Tone), thermoplastic acrylic resin (Acrytone) were used as materials for this study. One hundred five specimens were fabricated. For the color stability test, specimens were immersed in the coffee and green tee for 1 and 8 weeks. Color change was measured by spectrometer. Water sorption was tested after 1 and 8 weeks immersion in the water. For the test of cytotoxicity, cell viability assay was measured and cell attachment was analyzed by FE-SEM. RESULTS All types of denture base resin showed color changes after 1 and 8 weeks immersion. However, there was no significant difference between denture base resins. All specimens showed significant color changes in the coffee than green tee. In water sorption test, thermoplastic acrylic resin showed lower values than conventional heat-polymerized acrylic resin and thermoplastic polyamide resin. Three types of denture base showed low cytotoxicity in cell viability assay. Thermoplastic acrylic resin showed the similar cell attachment but more stable attachment than conventional heat-polymerized acrylic resin. CONCLUSION Thermoplastic acrylic resin for the non-metal clasp denture showed acceptable color stability, water sorption and cytotoxicity. To verify the long stability in the mouth, additional in vitro studies are needed.
Collapse
Affiliation(s)
- Dae-Eun Jang
- Department of Prosthodontics, School of Dentistry, Chosun University, Gwangju, Republic of Korea
| | - Ji-Young Lee
- Department of Prosthodontics, School of Dentistry, Chosun University, Gwangju, Republic of Korea
| | - Hyun-Seon Jang
- Department of Oral Pathology, School of Dentistry, Chosun University, Gwangju, Republic of Korea
| | - Jang-Jae Lee
- Department of Computer Science and Statistics, College of Natural Sciences, Chosun University, Gwangju, Republic of Korea
| | - Mee-Kyoung Son
- Department of Prosthodontics, School of Dentistry, Chosun University, Gwangju, Republic of Korea
| |
Collapse
|
37
|
Savabi G, Savabi O, Dastgheib B, Nejatidanesh F. Effect of the processing cycle on dimensional changes of heat-polymerized denture base resins. Dent Res J (Isfahan) 2015; 12:301-6. [PMID: 26288618 PMCID: PMC4533186 DOI: 10.4103/1735-3327.161423] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
Background: The second processing cycle for adding the artificial teeth to heat-polymerized acrylic resin denture bases may result in dimensional changes of the denture bases. The aim of this study was to evaluate the dimensional changes of the heat-polymerized acrylic resin denture bases with one and two-cycle processing methods. Materials and Methods: A metal edentulous maxillary arch was used for making 40 stone casts. Maxillary complete dentures were made with heat-polymerized acrylic resins (Meliodent and Acropars) with one and two stage processing methods (n = 10 for each group). Linear dimensional changes in anteroposterior and mediolateral distances and vertical changes in the first molar region were measured following each processing cycle, using a digital caliper. Mean percentage of the dimensional changes were subjected to two-way analysis of variance and Tukey honest significant difference tests (α = 0.05). Results: Postpolymerization contraction occurred in both anteroposterior and mediolateral directions in all studied groups; however, the vertical dimension was increased. Acropars acrylic resin showed the highest dimensional changes and the second processing cycle significantly affected the measured distances (P < 0.05). Meliodent acrylic resin was not significantly influenced by the processing method. Conclusion: Reheating of the acrylic resin denture bases for the addition of denture teeth result in linear dimensional changes, which can be clinically significant based on the acrylic resin used.
Collapse
Affiliation(s)
- Ghazal Savabi
- Department of Prosthodontics, Dental School, Isfahan (Khorasgan) Branch, Islamic Azad University, Isfahan, Iran
| | - Omid Savabi
- Torabinejad Dental Research Center and Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Badrosadat Dastgheib
- Torabinejad Dental Research Center and Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Farahnaz Nejatidanesh
- Dental Materials Research Center and Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| |
Collapse
|
38
|
Shah RJ, Katyayan MK, Katyayan PA, Chauhan V. Prosthetic rehabilitation of acquired maxillary defects secondary to mucormycosis: clinical cases. J Contemp Dent Pract 2014; 15:242-9. [PMID: 25095851 DOI: 10.5005/jp-journals-10024-1522] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Maxillary necrosis can occur due to bacterial infections such as osteomyelitis, viral infections, such as herpes zoster or fungal infections, such as mucormycosis, aspergillosis etc. Mucormycosis is an opportunistic fungal infection, which mainly infects immunocompromised patients. Once the maxilla is involved, surgical resection and debridement of the necrosed areas can result in extensive maxillary defects. The clinician is to face many a challenge in order to replace not only the missing teeth, but also the lost soft tissues and bone, including hard palate and alveolar ridges. The prosthesis (Obturator) lacks a bony base and the lost structures of the posterior palatal seal area compromise retention of the prosthesis. Furthermore, the post surgical soft tissues are scarred and tense, which exert strong dislodging forces. The present article describes the prosthetic rehabilitation of maxillary necrosis secondary to mucormycosis in two cases, one completely edentulous and the other partially edentulous.
Collapse
Affiliation(s)
- Rupal J Shah
- Professor and Head, Department of Prosthodontics, Government Dental College and Hospital, Ahmedabad, Gujarat, India
| | - Manish Khan Katyayan
- Assistant Professor, Department of Dentistry, GMERS Medical College Gandhinagar, Gujarat, India
| | - Preeti Agarwal Katyayan
- Assistant Professor, Department of Prosthodontics, Government Dental College and Hospital, Ahmedabad, Gujarat, India
| | - Vishal Chauhan
- Assistant Professor, Department of Prosthodontics, Government Dental College and Hospital, Ahmedabad, Gujarat, India
| |
Collapse
|
39
|
Salloum AM. Influence of high expansion dental stone used as investing medium on the changes in occlusal vertical dimension of complete dentures. Saudi Dent J 2013; 25:135-40. [PMID: 24371379 DOI: 10.1016/j.sdentj.2013.10.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2013] [Revised: 09/22/2013] [Accepted: 10/07/2013] [Indexed: 10/26/2022] Open
Abstract
PROBLEM STATEMENT Despite advances in materials and techniques, complete dentures made of acrylic resin experience an increase in the occlusal vertical dimension (OVD) during processing. Many factors that affect the OVD of complete dentures are known. However, no study has examined the effect of using high-expansion dental stone (type V) as an investing material on the OVD. PURPOSE This study investigated the effects of using a high-expansion dental stone as an investing material on changes in the OVD of complete dentures. MATERIAL AND METHODS Twenty sets of simulated upper and lower dentures were processed by the compression molding technique. Specimens were equally divided into 2 groups. In the dental stone type III (DST III) group, the lower, middle, and upper parts of a flask were filled with DST III. In the dental stone type V (DST V) group, the procedure was the same as in the DST III group, except that the middle layer was made of high-expansion DST V. Changes in the OVD were measured before and after denture processing. Collected data were analyzed with t-test statistics. Differences were considered statistically significant at the 95% confidence level. RESULTS Both groups showed a small increase in the OVD as a result of processing, but the OVD increase was significantly less in the DST V group compared to the DST III group. CONCLUSION High-expansion DST V can be recommended as an investing material to reduce the increase in the OVD that may occur while processing complete dentures.
Collapse
Affiliation(s)
- Alaa'a M Salloum
- Department of Removable Prosthodontics, Faculty of Dental Medicine, Damascus University, Damascus, Syria
| |
Collapse
|
40
|
Artopoulos A, Juszczyk AS, Rodriguez JM, Clark RK, Radford DR. Three-dimensional processing deformation of three denture base materials. J Prosthet Dent 2013; 110:481-7. [DOI: 10.1016/j.prosdent.2013.07.005] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
41
|
El Bahra S, Ludwig K, Samran A, Freitag-Wolf S, Kern M. Linear and volumetric dimensional changes of injection-molded PMMA denture base resins. Dent Mater 2013; 29:1091-7. [PMID: 24001949 DOI: 10.1016/j.dental.2013.07.020] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2012] [Revised: 05/10/2013] [Accepted: 07/24/2013] [Indexed: 11/15/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate the linear and volumetric dimensional changes of six denture base resins processed by their corresponding injection-molding systems at 3 time intervals of water storage. MATERIALS AND METHODS Two heat-curing (SR Ivocap Hi Impact and Lucitone 199) and four auto-curing (IvoBase Hybrid, IvoBase Hi Impact, PalaXpress, and Futura Gen) acrylic resins were used with their specific injection-molding technique to fabricate 6 specimens of each material. Linear and volumetric dimensional changes were determined by means of a digital caliper and an electronic hydrostatic balance, respectively, after water storage of 1, 30, or 90 days. Means and standard deviations of linear and volumetric dimensional changes were calculated in percentage (%). Statistical analysis was done using Student's and Welch's t tests with Bonferroni-Holm correction for multiple comparisons (α=0.05). RESULTS Statistically significant differences in linear dimensional changes between resins were demonstrated at all three time intervals of water immersion (p≤0.05), with exception of the following comparisons which showed no significant difference: IvoBase Hi Impact/SR Ivocap Hi Impact and PalaXpress/Lucitone 199 after 1 day, Futura Gen/PalaXpress and PalaXpress/Lucitone 199 after 30 days, and IvoBase Hybrid/IvoBase Hi Impact after 90 days. Also, statistically significant differences in volumetric dimensional changes between resins were found at all three time intervals of water immersion (p≤0.05), with exception of the comparison between PalaXpress and Futura Gen. SIGNIFICANCE Denture base resins (IvoBase Hybrid and IvoBase Hi Impact) processed by the new injection-molding system (IvoBase), revealed superior dimensional precision.
Collapse
Affiliation(s)
- Shadi El Bahra
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Germany; Department of Removable Prosthodontics, School of Dentistry, University of Damascus, Syria.
| | | | | | | | | |
Collapse
|
42
|
Asar NV, Albayrak H, Korkmaz T, Turkyilmaz I. Influence of various metal oxides on mechanical and physical properties of heat-cured polymethyl methacrylate denture base resins. J Adv Prosthodont 2013; 5:241-7. [PMID: 24049564 PMCID: PMC3774937 DOI: 10.4047/jap.2013.5.3.241] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2012] [Revised: 07/16/2013] [Accepted: 08/07/2013] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To evaluate the effect of various metal oxides on impact strength (IS), fracture toughness (FT), water sorption (WSP) and solubility (WSL) of heat-cured acrylic resin. MATERIALS AND METHODS Fifty acrylic resin specimens were fabricated for each test and divided into five groups. Group 1 was the control group and Group 2, 3, 4 and 5 (test groups) included a mixture of 1% TiO2 and 1% ZrO2, 2% Al2O3, 2% TiO2, and 2% ZrO2 by volume, respectively. Rectangular unnotched specimens (50 mm × 6.0 mm × 4.0 mm) were fabricated and droptower impact testing machine was used to determine IS. For FT, compact test specimens were fabricated and tests were done with a universal testing machine with a cross-head speed of 5 mm/min. For WSP and WSL, discshaped specimens were fabricated and tests were performed in accordance to ISO 1567. ANOVA and Kruskal-Wallis tests were used for statistical analyses. RESULTS IS and FT values were significantly higher and WSP and WSL values were significantly lower in test groups than in control group (P<.05). Group 5 had significantly higher IS and FT values and significantly lower WSP values than other groups (P<.05) and provided 40% and 30% increase in IS and FT, respectively, compared to control group. Significantly lower WSL values were detected for Group 2 and 5 (P<.05). CONCLUSION Modification of heat-cured acrylic resin with metal oxides, especially with ZrO2, may be useful in preventing denture fractures and undesirable physical changes resulting from oral fluids clinically.
Collapse
Affiliation(s)
- Neset Volkan Asar
- Department of Comprehensive Dentistry, Dental School, University of Texas Health Science Center at San Antonio, Texas, USA. ; Department of Prosthodontics, Dental School, Gazi University, Ankara, Turkey
| | | | | | | |
Collapse
|
43
|
Turagam N, Mudrakola DP. Effect of micro-additions of carbon nanotubes to polymethylmethacrylate on reduction in polymerization shrinkage. J Prosthodont 2012; 22:105-11. [PMID: 22985308 DOI: 10.1111/j.1532-849x.2012.00917.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
PURPOSE Carbon nanotubes are used in dentistry, although there are no adequate scientific data to support their use in acrylic resins. The polymerization shrinkage that occurs with polymethylmethacrylate (PMMA) resins is well known. This study compared the polymerization shrinkage of denture base acrylic resin with and without micro-additions of carbon nanotubes. MATERIALS AND METHODS Two materials were used, PMMA resin and multiwalled carbon nanotubes. Four groups were established of 10 specimens each according to the weight percent of carbon nanotubes dispersed and disintegrated in the monomer: group I (0.5% of carbon nanotubes in monomer), II (0.25%), III (0.125%), and IV (control group, 0%). The polymerization shrinkage of acrylic resin for each group was evaluated based on the distance between the reference points in wax (before polymerization) and in acrylic (after polymerization), measured using a traveling microscope. The data were submitted to Kruskal-Wallis and one-way ANOVA for comparison among the groups, and the results were statistically analyzed. RESULTS The Kruskal-Wallis test detected that the different percentages of carbon nanotubes incorporated in the monomer showed significant differences, and the mean ranks of polymerization shrinkage (%) showed differences among all the groups (group IV = 0.126, III = 0.037, II = 0.017, I = 0.006). Hence, the order of severity of polymerization shrinkage was 0% > 0.125% > 0.25% > 0.5% for the amount of carbon nanotubes incorporated in methylmethacrylate. CONCLUSION The present study was done to prove polymerization shrinkage in PMMA resins with micro-additions of carbon nanotubes. The results clearly show reduction in polymerization shrinkage when carbon nanotubes are incorporated into the PMMA resin.
Collapse
Affiliation(s)
- Neeraja Turagam
- Department of Prosthodontics, MNR Dental College, MNR Nagar, Sangareddy, India.
| | | |
Collapse
|
44
|
Garcia LDFR, Roselino LDMR, Mundim FM, Pires-de-Souza FDCP, Consani S. Influence of Artificial Accelerated Aging on Dimensional Stability of Acrylic Resins Submitted to Different Storage Protocols. J Prosthodont 2010; 19:432-7. [DOI: 10.1111/j.1532-849x.2010.00611.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
45
|
Machado DFM, Bertassoni LE, Souza EMD, Almeida JBD, Rached RN. Effect of additives on the compressive strength and setting time of a Portland cement. Braz Oral Res 2010; 24:158-64. [DOI: 10.1590/s1806-83242010000200006] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2009] [Accepted: 12/16/2009] [Indexed: 11/22/2022] Open
|
46
|
Consani RLX, Mesquita MF, Sobrinho LC, Sinhoreti MAC. Dimensional accuracy of upper complete denture bases: the effect of metallic flask closure methods. Gerodontology 2009; 26:58-64. [PMID: 19278521 DOI: 10.1111/j.1741-2358.2008.00234.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
OBJECTIVES To verify the dimensional accuracy of upper complete denture bases under the effect of different methods of metallic flask closure. MATERIALS AND METHODS Wax record bases were assigned to six groups: 1-2: traditional clamp; 3-4: RS system; and 5-6: flask with screws. Flasks were immediately polymerised or bench stored for 6 h prior to polymerisation. Resin base-cast sets were sectioned at regions corresponding to the canines, first molars and posterior palatal zone. Gap discrepancies were measured at five points: right and left ridge crests, palatal midline, and right and left marginal limits of the flanges. An optical micrometer was used for measurement purposes. RESULTS Data were submitted to anova, and the means compared by Tukey's test (alpha = 0.05). Results revealed significant differences in the flask closure technique, polymerisation time, section, and their interactions. Discrepancy values for the RS system and flask with screws were significantly lower than those related to the traditional clamp, regardless of whether resin polymerisation was immediate or delayed for 6 h. CONCLUSIONS Flask closure methods should be considered when the denture base stability and comfort of the patient are being assessed during clinical use of the dentures.
Collapse
Affiliation(s)
- Rafael Leonardo Xediek Consani
- Department of Prosthodontics and Periodontics, Piracicaba Dental School, State University of Campinas, Sao Paulo, Brazil.
| | | | | | | |
Collapse
|
47
|
Consani RLX, Mesquita MF, Correr-Sobrinho L, Tanji M. Dimensional stability of distances between posterior teeth in maxillary complete dentures. Braz Oral Res 2006; 20:241-6. [PMID: 17119707 DOI: 10.1590/s1806-83242006000300011] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2005] [Accepted: 05/12/2006] [Indexed: 11/22/2022] Open
Abstract
The aim of this study was to assess the displacement of posterior teeth in maxillary complete dentures stored in water at 37 degrees C. Twenty acrylic resin-based maxillary complete dentures were constructed with the anterior teeth arranged in normal overlap and the posterior teeth in Angle class I. Metallic pins were placed on the labial cusp of the first premolars (PM), and on the mesiolabial cusp of the second molars (M). The final acrylic resin pressing was made in a metallic flask with aid of the RS tension system, and polymerized in a moist-hot cycle at 74 degrees C for 9 hours. The dentures were deflasked after cooling in their own polymerizing water or after cooling in polymerizing water plus bench storage for 3 hours, and stored in water at 37 degrees C for periods of 7, 30, and 90 days. Following deflasking and after each storage period tested, the PM-PM (premolar to premolar), M-M (molar to molar), LPM-LM (left premolar to left molar), and RPM-RM (right premolar to right molar) distances were measured with an STM Olympus microscope, with an accuracy of 0.0005 mm. Collected data were submitted to ANOVA and Tukey's test (5%). There was no statistically significant difference for the PM-PM, M-M, and LPM-LM distances after all storage periods when the flask cooling methods were considered. With exception of the RPM-RM distance after the 30-days water plus bench storage period, the other distances remained statistically stable.
Collapse
|
48
|
Shukor SSABD, Juszczyk AS, Clark RKF, Radford DR. The effect of cyclic drying on dimensional changes of acrylic resin maxillary complete dentures. J Oral Rehabil 2006; 33:654-9. [PMID: 16922738 DOI: 10.1111/j.1365-2842.2006.01615.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Poly(methyl methacrylate) dentures may exhibit dimensional changes when drying. Drying has been shown to destroy Candida albicans. This study investigates the effect of simulating overnight cyclic drying on dimensional changes of four complete denture base materials. Denture specimens used in this study had been prepared for a previous study. All dentures had been kept hydrated at room temperature for 2 years. The materials used were, group 1, conventionally packed and cured Trevalon, group 2 was injection moulded and conventionally cured (Trevalon Success), group 3 (Acron MC) and group 4 was Microbase, which is injection moulded and microwave cured. The measurements of the inter-molar and inter-premolar width, and anterior posterior dimension between the premolars and molars were recorded after 8 h drying and then after four cycles of dehydration and rehydration. The dentures were more dimensionally stable in the anterior posterior than the cross arch dimension. There was a statistically significant (P < 0.02) increase in the intermolar width for Trevalon, Trevalon Success and Acron after 8 h drying and after four cycles. There was a statistically significantly difference between Microbase and the other materials after 8 h drying and there was a significant difference between the injection moulded groups in the interpremolar width (Trevalon Success versus Acron, Trevalon Success versus Microbase) after cyclic drying. Although statistically significant dimensional changes were observed for all materials these were small and were considered not to be clinically significant. Microbase was the least dimensionally stable material during air-drying.
Collapse
Affiliation(s)
- S S A B D Shukor
- Department of Prosthodontics, King's College London Dental Institute at Guy's, King's College and St Thomas' Hospitals, London, UK
| | | | | | | |
Collapse
|
49
|
Consani RL, Domitti SS, Mesquita MF, Consani S. Influence of Flask Closure and Flask Cooling Methods on Tooth Movement in Maxillary Dentures. J Prosthodont 2006; 15:229-34. [PMID: 16827735 DOI: 10.1111/j.1532-849x.2006.00111.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
PURPOSE This study investigated the tooth movement of standardized simulated dentures processed by traditional closure or the new Rafael Saide (RS) tension system when cooled in the curing water itself or in curing water followed by bench storage for 3 hours. MATERIALS AND METHODS Forty stone casts were formed from a mold of an edentulous maxillary arch. The wax denture record bases were made on the casts; the height of the wax rim occlusion was 20 mm in the labial sulcus of the cast and 10 mm in the posterior region. The upper stone cast was mounted on a Mondial 4000 semi-adjustable articulator with wax rim interocclusal references in relation to the lower stone cast teeth. Metallic pins were placed in the incisal border of the maxillary central incisors (I), labial cusp of the first premolars (PM), and mesiolabial cusp of the second molars (M). The incisor-to-incisor (I-I), premolar-to-premolar (PM-PM), and molar-to-molar (M-M) transversal distances and left incisor-to-left molar (LI-LM), and right incisor-to-right molar (RI-RM) anteroposterior distances were measured before and after denture polymerization with an optical microscope with a tolerance of 0.0005 mm. For traditional closure, the dentures were flasked conventionally in standard metallic flasks, which were afterward placed in spring clamps. For the new RS system closure, the flasks were pressed between the metallic plates of the tension system after the final closure. The Clássico heat-polymerizing acrylic resin dough was packed in the flasks under a final packing pressure of 1.250 kg f. Twelve hours after flask closure, the dentures were polymerized in a moist heat-polymerizing cycle for 9 hours at 74 degrees C. The denture was deflasked after cooling in the water of the polymerizing cycle (groups A and C) or in the water of the polymerizing cycle and then bench-stored for 3 hours (groups B and D). Collected data were analyzed with analysis of variance and Tukey's test (p< 0.05). RESULTS There was no statistically significant difference (p> 0.05) between the conventional and new RS system closure methods for the transversal distances after polymerization in all studied groups. The anteroposterior distances did not change with deflasking after water bath cooling. There were statistically significant differences (p< 0.05) in the anteroposterior distances with deflasking after water bath cooling and then bench storage for 3 hours. CONCLUSION Tooth movement was similar in dentures processed by traditional closure and by the new RS tension system, with the exception of the anteroposterior distances when the flasks were cooled in their own curing water and bench-stored for 3 hours.
Collapse
Affiliation(s)
- R L Consani
- State University of Campinas, Piracicaba School of Dentistry, São Paulo, Brazil.
| | | | | | | |
Collapse
|
50
|
Consani RLX, Mesquita MF, Consani S, Correr Sobrinho L, Sousa-Neto MD. Effect of water storage on tooth displacement in maxillary complete dentures. Braz Dent J 2006; 17:53-7. [PMID: 16721466 DOI: 10.1590/s0103-64402006000100012] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The purpose of this study was to investigate the effect of water storage at 37ºC (1 week, 1 month and 3 months) on tooth displacement in maxillary complete dentures. Ten maxillary dentures were constructed with Clássico acrylic resin using the conventional method of packing in metallic flasks. Metallic reference pins were placed in the incisal border of the central incisors (I), labial cusp of the first premolars (PM), and mesiolabial cusp of the second molars (M). Twelve hours after final flask closure, the acrylic resin was cured in water at 74ºC for 9 h. The flasks were removed from the thermo-polymerizing unit after water-cooling and the dentures were deflasked, finished and stored in water at a temperature of 37ºC for 1 week, 1 month and 3 months. At deflasking and at the water storage intervals, the I-I (incisor to incisor), PM-PM (pre-molar to pre-molar), and M-M (molar to molar) transversal distances, and LI-LM (left incisor to left molar) and RI-RM (right incisor to right molar) anteroposterior distances were measured using an optical microscope with 0.0005 mm accuracy. Data were submitted to ANOVA and Tukey´s test (5%). Comparing the evaluation periods for each individual transversal and anteroposterior reference point, no statistically significant differences were observed among deflasking and the water storage intervals for I-I, PM-PM, M-M and RI-RM distances (p>0.05). For LI-LM, however, deflasking values were statistically different from those of 1-week, 1-month and 3-month water storage intervals (p<0.05), which, in turn, did not differ statistically to each other (p>0.05). These results confirm the complexity of tooth displacement in complete dentures. From a clinical standpoint, the difference observed in LI-LM distance after water storage would not be detected by the patients during clinical use.
Collapse
Affiliation(s)
- Rafael Leonardo Xediek Consani
- Department of Prosthodontics and Periodontics, Faculty of Dentistry of Piracicaba, State University of Campinas, Piracicaba, SP, Brazil.
| | | | | | | | | |
Collapse
|